Home
        SERVICE MANUAL
         Contents
1.          Capacitance is out of work                               Insert again  electrify and test                Main control board is out of work                      Compressor doesn    t start  sometimes because the  temperature in case is   between starting and stop  temperature  should pay  attention when do test          Adjustment of thermostat  Temperature of  environment     gt 30  C 1 3 grade  16 30  C 3 5grade   lt 16   5 7grad          ANALYSIS OF SERVICE AND TROUBLE SHOOTING       Part 6 Analysis of Troubles and Troubleshooting   A  Poor Refrigerating Effect  The so called    poor refrigerating effect     refers to the fact that the refrigerator can operate and   refrigerator normally  but the temperature in the refrigerator cannot drop to the prescribed value  under the stipulated working conditions  In view of there are many causes for this phenomenon  we  are going to discuss and analyze it in the following 7  aspects     1  Leakage of refrigerant   ANALYSIS OF TROUBLE   The leakage of refrigerant in the system will result in an insufficient refrigerating capacity  the  resulting phenomena are its lower gas suction pressure and exhaust pressure as well as higher  exhaust gas temperature  The exhaust tube feels rather hot  and a continuous gas flowing sound  louder than usual can be heard at the outlet of the capillary  and no frost or a smaller quantity of loose  frost appears on the evaporator  After shut down  the balance pressure in the system is usually l
2.       ii  p Whether lighting                   am and display system is I    N      Trouble of lighting and display system    77  normal p              Y  M  _   hether the       __   lt  lt  grade of thermostat is      ees      onto    N    m    x  RS           Wh ether the         lt  lt  resistance of compressor is                      Y           SE    infinite or 0           infiniteorQ     N      280   dii De     Whether th        E starting current is    TR pe         about5A  gt     hether                                 Measure whether               two ends of heat protector   is through p  M      and then swing back slowly  when measuring two  les of capacitance          2   o Whether        compressor pin is tight        _    98  gt   N    contact          is good           Y       256           Whether input           TT and output voltage of main     eontrol board is norma      ue          9     5      Whether each            C contact of main control board               ol       NN al    71  n           TT  Tighten each         contact and test machine          again p  OK    m yvr         PEN D Yy    LU       N             Ex    gt  N gt              Adjust the grade according to fact             Compressor is open circuit or short  circuit                Inner trouble of compressor                            If it is infinite         then the starter is  out of work           Heat protector is out of work                      JosseJdujoo mau    10            
3.  144 54 7 57  Depth with open door cm 108   Net weight kg 47 0  Packing dimensions H W D cm 148x 57 8 x59 8  Gross weight kg 53 0    Users instruction    Others    weight in 0     languages        D GB F I E                         PARTS IDENTIFICATIONS   T  ventition grine         Work surface   cover plate                 Freezing compartment         interior light   temperature controller   S  storage toma       Water drain channel        Glass  Plexiglas shelf     Vegetable tray s    Storage compartment   Can   bottle rack   Oo     3  Compressor    14  contact switch for interior fight        vo vu   Door of freezer compartment         Egg tray     Defrost water drain hole    Stopper inserted in fridge cover      Defrost water collection tray  To defrost freezer nt   pull out tray  remove stopper  18    replace tray                                 according to the model       SYSTEM FLOW PRINCIPLE  1  Schematic Diagram of Refrigerating Principle    1  Compressor  2  Condenser   3  Dry Filter   4  Capillary Tube    5  Evaporator       2  Brief Description of System Flow Chart  3 6 series is a direct cooling single system refrigerator  which has a freezer compartment   When the refrigerator is just powered on  the  refrigerant flows in the sequence   1  gt 2  gt 3  gt 4  gt 5     CIRCUIT DIAGRAM  CIRCUIT DIAGRAM    THERMOSTAT       MAINTENANCE SERVICE AND TROUBLE SHOOTING       Part5  Maintenance Service and Trouble Shooting    5 1 When the refrigerator does not get cold at
4.  all                No cooling     If compressor   NO Check and repair according to  can run after it stop to         the section of  the compessor  run five minutes and   doesn t work      give power       YES  If compressor   Refrigerant  can run naturally     4   NO leak  check and  temperature raising              repair charge    of condenser is    refrigerant again   very low  lt   YES       Block by ice or dirty   When charging refrigerant we must    things  change filter and change   notice to make refrigerant true     refrigerant again     5 2  Normal Phenomena   Not Troubles for Refrigerators   In a domestic refrigerator  there is not only a complicated electric control system  but also a  refrigerating system that is difficult to discern whether it is in a good working condition  Both the  systems are related and affect each other  If a certain part of a refrigerator works abnormally  Its  refrigerating efficiency will decrease  operation properties will become unstable  or even it cannot be  used normally for those serious cases  Refrigerators are generally of larger volume  once troubles  appear  to send them to a service department is really a tough thing  if such is the case  the user will  always be in suspense  sometimes  normal phenomena will be erroneously regarded as  troubles  Therefore  before we deal with the topics of frequently occurring troubles of refrigerators and  their remedies  we should firstly give a brief account of some normal phenomena whic
5.  handle or other metal parts with your hand  Test  the refrigerator with a test pencil  it will light up intensively  measure the resistance between the power  cord plug and the case body with an avometer  the reading will be zero  0    in the worst case  the  fuse will be blown  Check the 3 prong outlet to see whether the live wire and the null line are inversely  connected  this makes the ground protection lead out from the power cord plug being connected to the  live wire  Another possibility is that the live wire and null line of the outdoor power supply circuit have  been inversely connected accordingly  this makes the null line become a live wire     G  Stronger vibration and loader noise   1  Refrigerator placed improperly   a  Uneven ground   Uneven ground will cause the refrigerator to be placed unsteadily  causing stronger vibration and  noise during its operation     b  Leveling screws not properly adjusted   If the leveling screws on refrigerator legs have not been adjusted properly  vibration and noise will still  occur even if the refrigerator has been placed on a level ground     2  Abnormal noise from compressor    Poor cooling          7 C room poor cooling       Display section for so  freezer appear F5       Poor cooling                           Voltage between  187V 242V    Check and adjust the  circuitry    temperature is under  16C           onduct user to use    Much too food or too dense    it properly     frigeration norma  cooling          27 Croom 
6.  the   compressor  strike different locations on the side surface of its case using a rubber hammer or hand  hammer with a wood block in between so as to determine whether the suspended springs are out  of balance or being seized     The contacts of thermal relay sometimes may be open due to the leakage of temperature sensing  agent from the temperature sensor    Remedy   Remove the relay cover to check up its contacts  if they are open  this means that the original setting is  not properly set or temperature sensing agent has leaked out of the temperature sensor  Try to turn the  adjusting stem of this value in the direction of the lower temperature graduation  then check the    contacts to see whether they are closed  If they are still not closed  dismantle the temperature sensing  disc and then immerse it into warm water to see whether the contacts actuate  if not  it can be  preliminarily determine that temperature sensing agent has leaked out  and it must be replaced with a  new thermostat    4  Motor troubles and other electric faults   a  Motor windings have been burned or short circuited between turns   ANALYSIS OF TROUBLE   When motor windings have been burned or short circuited between turns  the fuse will be blown  repeatedly  and the blowout occurs particularly at the instant when you close the knife switch   REMEDY   Check the terminals and the outer casing to see whether they are short circuited  and measure the  resistance of each phase with an avometer  If sho
7.  the major parts in the refrigerating system has been performed improperly   the effect of air purging for the whole system is not good  or the water content in the refrigerant is out of  standard  all these will cause the expansion valve to be clogged with ice  The symptom for this trouble  are as follows  the refrigerator sometimes can refrigerate and sometimes cannot  the refrigerator  compartment works normally at the beginning  but after working for a certain period of time  frosting  begins at the clogged position  evaporation temperature reaches below 0  C  water will accumulate at  the narrow part of the capillary and clog it gradually  then frost begins to melt at the evaporator  no gas  flowing sound can be heard  and the gas suction pressure assumes a state of vacuum  Note that these  phenomena will appear intermittently   sometimes  the   refrigerator works well  and sometimes not well  In order to determine whether it is clogged with  ice  heat the suspicious points with hot water to make ice melt  and after a while if a gas flowing sound  resulting from an abrupt gush is heard and the gas suction pressure rises as well  it can be confirmed  that the trouble is caused by ice clogging     REMEDY   If there is too much moisture in the refrigerating system  it is advisable to release the refrigerant  purge  the tubing with nitrogen  and then charge the system with the filtered refrigerant  However  the  commonly adopted method is to connect a filter with moisture ab
8.  to the noises produced when the compressor is running Hums from a fully enclosed  aggregate unit is the sound caused by overload indicating that the motor cannot be started  normally  meanwhile  a clattering sound can be heard from inside the start relay which is produced  because the start contacts cannot be released normally  A whistling sound is caused by the high  pressure gas flowing out of the crack of the pressure tube inside the compressor  and clucks are the  sound of striking after the suspended spring inside the compressor has broken    During the normal operation of compressor  a slight and uniform hum sound due to undulation of  electric current can be heard generally  this is a normal phenomenon  However  if it sounds like       tong  tong        i e   an impact sound inside the compressor  this means that a large quantity of wet  vapour of refrigerant or refrigerating oil has come into the compressor cylinder  if it sounds like   dang  dang      a striking sound of metal parts inside the compressor  this means that some moving    parts have loosened  note to differentiate this  sound from those formed during starting or stopping the compressor     b  Listen to the sound caused by the flowing of gas in the evaporator Open the refrigerator door  while the compressor is in operation  incline your ear and listen attentively the gas flow sound inside  the evaporator  If it sounds like gentle whistling accompanied by a sound similar to water flowing  this  is the so
9. CAUTION      READ THIS MANUAL CAREFULLY TO     1 e DIAGNOSE TROUBLE CORRECTLY  BEFORE OFFERING SERVICE     Refrigerator  SERVICE MANUAL    1  Mechanical temperature control   2  Adjustable thermostat   3 100  HFC free and FCKW free   4  External condenser and adjustable feet  5  stylish interior light    Haier Group    CONTENTS    CONTENTS one 1  SAFETY PRECAUTIONS   dn desee adr d dd aie de tet ei t tee ion eode 2  SPECIFICATION S            teet t rette ciii bu Rei etre 4  PARTS IDENTIFICATIONS 2  sonde      Sd anti  6  SYSTEM FLOW PRINCIPLE   5 252 3  aid aaa di tecto teet eodera 7  CIRCUIT DIAGRAM                            t edet i etri crit bu dii ae tret 8  MAINTENANCE SERVICE AND TROUBLE SHOOTING                                                    9    ANALYSIS OF TROUBLES AND TROUBLESHOOTING                                                  13    SAFETY RECAUTIONS Sn    Check if there is any leak of current    Cut out the power supply before the repair to avoid an electrical shock hazard    In the case of a live line test  insulating gloves should be worn to avoid potential electrical shock   Confirm the rated current  voltage and capacity before testing with any kinds of instruments    Watch if the upper door is open when you check something at a lower position    Take out every part in the cabinet before moving the machine  especially things like panels  e g  glass  shelf     Please wear intact cotton gloves when repair any parts of the evaporator  so that scratches 
10. EMEDY   Check the heat insulation layer for its damaged parts  repair it to improve its heat insulation property  If  the door has deformed or the door seal is not tightly sealed against the case body  repair them   respectively    5  Too much food is placed in the refrigerator  or is placed too densely  resulting in poor ventilation or  poor conditions for temperature sensing  and hence no stoppage of the compressor    6  Too high ambient temperature  poorer ventilation and heat dissipation make the compressor  running without stop    F  Electric leakage of refrigerator   1  Slight electric leakage    Electric insulation has deteriorated due to being affected with damp  thus resulting in slight electric  leakage    2  Serious electric leakage   Refrigerator case has become live due to faults occurred in some electric devices or the erroneous  wiring in installing power cord plug or outlet by the user  This is very dangerous    3  Electric leakage test   a  Slight electric leakage      tingle sense will be experienced as soon as you touch the metal parts of the refrigerator with your  hand When        test them with a test pencil    its neon lamp will come on  In that case  the first thing  you need to do is to determine whether the grounding is perfect  If the grounding is no problem  turn off  the refrigerator immediately  then check the insulation of electric circuits with an avometer     b  Serious electric leakage   Never touch the case body of the refrigerator  its door
11. F TROUBLE   Total clogging of a filter is rarely to occur  This trouble is mostly caused by the paste like matter formed  from the substances filled into the system or other dust after the refrigerator has been used for a    longer time  or by the dirt accumulated gradually inside the filter  Sometimes  tapping the filter nay  cause a passage for flowing  Touching it with your hand  you will feel that it is cooler compared with its  temperature in the normal state    REMEDY   The same as described in the capillary clogging with dirt    3  Troubles of Compressor   a  Breakage of gas suction and discharge valve blocks   ANALYSIS OF TROUBLE   The compressor works by means of the opening and closing of gas suction valve and discharge valve  to suck and discharge the refrigerant  If the valve block is broken  the refrigerant can not be  discharged  and hence no refrigerating can be achieved    METHOD FOR MAKING JUDGEMENT   It is quite difficult to differentiate this trouble from others because they often have similar symptoms  In  repairing  firstly  hear attentively if there is some abnormal sound coming from the compressor   sometimes   the broken pieces of valve block may strike against the cylinder   and feel the  compressor casing with your hand to ascertain whether it is too hot  this is also helpful to the  troubleshooting  secondly  measure the pressures at the high and low pressure ports of the  compressor with pressure gauges  if the gas suction valve block is broken  th
12. age due to electric troubles   a  Thermostat is out of control   ANALYSIS OF TROUBLE   In case the thermostat does not work in its good order or its temperature sensor has not been installed  properly  frequent stoppage is also likely to occur    REMEDY   Try to adjust the temperature sensor   s position until the compressor can be started and stopped  normally  If this cannot be achieved  and the stoppage still occurs repeatedly  it is most likely that the  mechanical parts or contacts are out of order  disassemble the thermostat  make a thorough checkup  and repair it    b  Overload of electric motor   ANALYSIS OF TROUBLE   Probably  too many things have been put into the refrigerator  and hence the thermal load exceeds its  refrigerating capacity   or in case the power supply voltage drops considerably  the current flowing  through the motor will increase drastically making the thermal protector actuate and the fuse blown    and hence the motor stops running  If the motor is still running continuously in such a case   its  windings will be burned out     REMEDY   Reduce the thermal load  pay attention to the variation in voltage of the power supply    c  Abnormal thermal protection   ANALYSIS OF TROUBLE   The compressor current is within its normal range  but the thermal protector actuates repeatedly   REMEDY   Replace the thermal protector with a new one    3  Sudden stoppage due to other causes   NORMAL STOPPAGE   Start and stop of the compressor is generally controlled 
13. ator  purge it thoroughly and then dry it  In case it is difficult  to dismantle it  charge refrigerant from the evaporator inlet to wash it several times  then purge and dry  it with nitrogen     7  Flowing obstructed in refrigerating system   ANALYSIS OF TROUBLE   Because the refrigerating system was originally not purged thoroughly  some of the filter screen  meshes have been clogged by dirt accumulated in the filter after using it for a certain time of  period  thus resulting in a decrease in flow rate  and hence a poorer refrigerating effect     The abnormal phenomena caused by this kind of slight clogging in the system are as follows  the gas  discharge pressure is lower  the temperature of discharged gas drops down  the position clogged has  a temperature lower than that in normal conditions  and for a severe clogging  even dew condensation  as frosting may appear     REMEDY   Purge the tubing  and after replacing the dry filter with a new one or clearing it thoroughly  recharge the  system with refrigerant and seal the charging port      B  No Refrigerating   The phenomenon that the compressor runs normally  but no frost  or only a little frost   appears on the  evaporator  and the refrigerator temperature does not drop down is called    no refrigerating     There are  many causes for this trouble and it is relatively complicated   too   In servicing  special attention to  finding direct causes for this phenomenon  Three main potential causes for this trouble are anal
14. by a thermostat   When the temperature in the  refrigerator reaches its desired value  the thermostat will shut down the compressor automatically   Never take this normal operation as a trouble  care should be taken to differentiate it from other real  troubles in servicing    D  Compressor won  t start   In case the compressor cannot be started  you must find out the origins of this trouble through checkup    step by step  because probably there are many causes  including those electrical and mechanical    1  Inspect the power supply to see whether it is connected to the compressor circuit    ANALYSIS OF TROUBLE   In case the compressor cannot be started  this will generally exhibit in the power supply circuit  for  instance  power failure  poor contact of switch  and blown fuse  Make a comprehensive analysis of  these phenomena  fine out its real cause and take correct measures to remove this trouble    REMEDY   a  Check the input power circuit to see whether where is voltage of the power supply  namely  the  circuit which is connected to the knife switch  This can be determined with an avometer or a test pencil   If a blown fuse is found  ascertain and remove its cause  then replace it with a new one of the same  specifications    b  Check the compressor accessories  including its thermal protector and relay  In case the thermal  protector is damaged  the compressor cannot be powered on  If the relay is out of order  the motor will  not run and hum sound can be heard from 
15. by the  sharp fins can be avoided    If there is a breakdown with the refrigeration system  please surrender the machine to the service  center  else the leaked refrigerant may pollute the atmosphere     The refrigerator use AC of 220V with a frequency of 50Hz       Abig fluctuation of voltage  exceed the range 220 240V  may cause a start failure of the refrigerator     a burn out of the control panel and compressor  or an abnormal sound from the compressor in    operation  In this condition an automatic voltage regulator over 750W should be added       Take care not to damage the supply line  Don   t yank at the line  pull the plug out gently from the    receptacle  Don   t press the line under the cabinet or step on it  Take care not to roll on or damage the    supply line when moves the machine from the wall       Don   t use the supply line any more when there is damage to the line or an abrasion to the plug  Go to    the authorized service center for a replacement       In the case of leakage of inflammable gases like carbon monoxide  open the door and windows  Don t    pull out or insert the plugs of the appliance       This product is designed only for household use  Any put of medicine  dangerous flammable     explosive articles and highly corrosive acid or base is forbidden       It is recommended not to put any receptacles  stabilized power supply or appliances like microwave    oven on the board of the refrigerator  Don   t use appliance within the refrigerator  ex
16. cept recommended    type   else there may be electromagnetic interference or other accidents       Don t store or use gasoline and other flammable articles near the refrigerator which may lead to a fire    20     21     22     23     24      accident       Don   t hook on the door  else the door        be slanted or the machine may be tipped over and injure    people       Don   t place unstable articles on the refrigerator  e g  weights and containers with water   else the    weights may hit people and the leaked water may cause leak of current       Don t touch the refrigeration surface of the freezing compartment when the refrigerator is in operation     especially when your hand is wet  else you may be glued to the surface    Don   t spray at the refrigerator  or locate it at a damp place  else the insulation of the refrigerator may  be impaired    Any disassembly or alternation to the refrigerator is strictly forbidden  Damage to the refrigeration  pipeline is prohibited  Service to the refrigerator must be carried out by professionals    Don   t put bottles of bear and other drinks into the refrigerator  else the bottles may be cracked with  cold    Pull out the plug of power supply during clearance or power outage  Wait at least five minutes to  resume the power supply in order to prevent damage to the compressor caused by continuous restart   Remove the door and the door seal when the refrigerator is out of use  in case that accident may    happen to children coming i
17. condensation appears due to the fact  that its temperature is obviously lower than the ambient temperature  this means that most meshes of  its screen has been clogged  resulting in an  obstructed flowing of refrigerant  thus causing a drop in temperature due to throttling     d  Feel the temperature of exhaust gas from the refrigerating system  the exhaust gas should be  very hot and this is the normal working state  For those refrigerator with enclosed type of compressor  refrigerating system  no frost or dew drop will from on the gas suction tube  otherwise  there is  something wrong in the system  Frosting and dew condensation may appear for a very short time  period when just starting the machine  this is a normal phenomenon    Because a refrigerator is a  combination of several components  they are related and have influence on each other  In case an  abnormal phenomenon has been found through the above mentioned checkups  you need not to  make a hasty conclusion based on only one abnormal phenomenon  It is advisable to find out two or  more abnormal phenomenon  or conduct troubleshooting comprehensively with the aid of instruments  or other ways  because several kinds of troubles may share a common abnormal phenomenon  and  two or more abnormal phenomena may occur simultaneously due to a certain trouble  With this  method  you can reject some suspicious troubles and finally make a correct judgment     5 4 Compressor doesn t start       Compressor  doesn    t start    Y
18. e suction pressure gauge  pointer will swing violently and the suction pressure is very high  whereas when the gas discharge  valve block is broken   the discharge pressure gauge pointer will swing drastically and the discharge  pressure is very high  In the both cases  stop the compressor at once  and if technique is available   open the cylinder cover and check up the valve block  repair it  or replace it with a new one    C  Sudden stop of Compressor during Its Running   The cause of sudden stop of a compressor during its running is mostly that the gas suction pressure  and or discharge pressure exceed their respective prescribed ranges  thus making a  pressure operated protective relay shut off the power to the compressor and stop it  In the following we  discuss mainly the reasons for causing excessively high gas discharge pressure and low suction  pressure    1  Stoppage due to excessively high gas discharge pressure   A  Too much refrigerant charged into the system   ANALYSIS OF TROUBLE   The phenomenon  such as loose frosting and poor refrigerating effect  may occur if excessive  refrigerant has been charged into the system  Superfluous refrigerant will occupy a certain space of  the evaporator  thus reduce its heat dissipating area  and the phenomenon of    liquid striking    may  occur  too  Meanwhile  dew or frost condensation may occur on the gas return tube  and the gas  discharge pressure will obviously rise  when it reaches the threshold value  the protective r
19. elay will  actuate and shut off the power supply to the compressor    REMEDY   Open the tubing  re evacuate and then charge the system with a proper quantity of refrigerant    b  Air left in the system   ANALYSIS OF TROUBLE   The residual air in the system will circulate together with the refrigerant in the system  The major  symptoms caused by this residual air is higher gas discharge pressure  higher discharged gas  temperature  the gas discharge tubing is considerably hot when you feel it with your hand   and poorer    refrigerating effect  Furthermore  the gas discharge pressure will exceed its normal value when the  compressor has run for a period not too long  thus making the protective relay actuate and bring to a  stoppage    REMEDY   Check up how the air has been left in the refrigerating system  Generally  there are two possibilities   one is that the air has been sucked into the system when repairing due to carelessness  or it has not  been purged out totally when evacuating the system  the other is that there are leak points at the low  pressure end of the refrigerating system  Leak points appear mostly in those low temperature parts or  assemblies  because the evaporation temperature is lower for such low temperature devices   especially at the low pressure end  it is easier for the air goes into the system  Once it has been  ascertained that air does exist in the system  you have to open the tubing  re evacuate it and then  charge it with refrigerant    2  Stopp
20. h are not  troubles  In case any one of such phenomena occurs  there is no need to worry about it  and the user  can use it at total ease     1  When the compressor of a refrigerator has just stopped running  a rumbling sound can be heard  from inside its evaporator  This is a sound caused by the flowing of refrigerant in the evaporator  tubing  Because the pressure difference is still greater after the compressor has just stopped  running  the refrigerant will flow for a certain time   therefore  this sound is a normal phenomenon    2  A click sound can often be heard from the refrigerator  This is a normal sound produced by the  pull in or release of the armature of a current deadweight start relay when starting the  compressor  The compressor motor will produce a slight and uniform sound while it is running  This  sound is not easy to be heard in the  daytime  but of course it can be heard distinctly at night    3  The compressor consists of an electric motor and a compressing apparatus  During its normal  operation  the motor   s stator core and windings will rise to a temperature in the range of 100  C  110       and the temperature of the piston and cylinder of the compressing mechanism can also reach as  above 100  C due to the heat produced when compressing refrigerant  Most of the heat radiates to the  air through the compressor casing  therefore  its casing is generally at a temperature between 85   C 90 C    itis very hot  particularly in summer when the ambient te
21. igerating system  There is general no trouble indicating instrument mounted on the  domestic refrigerator locations and natures of troubles should be determined according to their  respective features    therefore    experience in servicing is very important to troubleshooting  Service  technicians with rich experience can correctly locate them and take reasonable remedy measures  based on their comprehensive analysis of trouble characteristics as well as operating conditions for  various kinds of refrigerators     Three Essentials for Checkup   1  Look   a  Check the tubing of refrigerating system for cracks and various welding points for leaks  if  leakage occurs  an oil stain can be seen definitely     b  Check the suction and exhaust pressure values  high pressure and low pressure  of compressor  to see whether they are normal         Check the conditions of frost attached to its evaporator and gas return tube  It is abnormal if frost  has formed on part of the evaporator or there is no frost attached to it     d  Pay attention to the speed of temperature drop inside freezer compartment  It is abnormal if the  speed of temperature drop is obviously slower than the corresponding normal speed         Check the environment to see whether it is suitable for placing a refrigerator     f  Check refrigerator door seal  case  table surface and heat insulation layer     g  Look at the main control board to ascertain if various indication states are normal     2  Listen   a  Listen
22. it after the compressor is turned on  in that case  shut it  down immediately  otherwise  the motor windings will be burned out in case this condition lasts longer   c  Check the relay contacts and plugs to see if they are perfect and work reliably  Poor contact may  cause the motor not running or humming    2  Check the circuit voltage to see whether it is normal    ANALYSIS OF TROUBLE   If the circuit voltage is obviously lower than its rated value  it will be difficult to start the motor  and a  hum sound can be heard from it    REMEDY   Measure the voltage with a voltmeter  if it is really too low  give directions to the user for buying a  stabilizer so as to step up the voltage  thus normal operation can be achieved    3  Check the thermal relay to see whether its contacts are closed    ANALYSIS OF TROUBLE   Three suspended spring inside the compressor case are out of balance  and strike against the  case  moreover  the wear of compressor parts may cause noise sometimes     3  Resonance of tubing and loosening of parts   Improper and compact laying of tubes or the loosening of parts may cause vibration and noise     4  Inspection method   To find the sources of noise  press the vibration spot with your hand while the refrigerator is in  operation and listen attentively whether the vibration becomes weaker or vanishes  If the refrigerator  has not been levelly placed  put a level meter on its top table and adjust the leveling screws on its  legs  In case noise occurs from
23. izing shaft and piston After the refrigerator has been powered on  the compressor will  not start and run  but a slight hum sound can be heard  and several seconds later  thermal protective  relay will actuate and make the contacts open  this process will occur repeatedly  but the compressor  cannot be started    E  Compressor won t stop   Sometimes  the compressor will run continuously for several hours or run without end   If the food  placed in the refrigerator is not too much  there may be the following two situations  i  the refrigerator  very low  this means that the control system is probably out of order  ii  the control system works    normally  and there are troubles in the refrigerating   system or other parts    1  Temperature is set improperly   a  The temperature control knob is set to the    coldest    position  This position is to be used for fast  freezing or continuous running  its temperature for power off is too low  therefore  the compressor  won t stop and the temperature in the refrigerator becomes lower and lower     b  Inspection method  check the temperature control knob to see whether it is set in the position   coldest     2  Thermostat is malfunctioning and makes the compressor running continuously   ANALYSIS OF TROUBLE   When the thermostat doesn t work normally  it will make the compressor run continuously  and hence  very low temperature will be achieved in the refrigerator  The fault is generally due to the fact that the  contacts of the therm
24. mperature is higher  All these are  normal phenomena     4  For the direct cooling refrigerator  a kind of irregular crack sound can be often heard when the  compressor is running for a certain period of time or has just stopped its running  This sound is caused  by the stress relief due to expansion and contraction when temperature changes  and will not affect  the normal application of refrigerator    5 3  Common Troubles in Refrigerators and Their Remedies   Causes for troubles occurring in refrigerators are closely related to the quality of components and  workmanship in assembling by manufacturers as whether refrigerators are properly used and  maintained  The parameters generally used to express the working conditions of a refrigerator include  the temperature inside the refrigerator  operation rate  electric power consumption  noise level  and  other functional indexes  If any one of  these parameters is beyond its permissible range  this indicates that there is a fault or trouble in the  refrigerator   During the whole service life of a refrigerator  the probability of troubles occurring within a  union time is called its failure rate Making a comparison between the control circuit system of a  refrigerator and its refrigerating system  we can find that the failure rate of the former is higher  and  that of the thermostat is the highest   In  troubleshooting  the first thing you must do is to determine where the trouble comes from     the control    system or the refr
25. n to play     SPECIFICATIONS          REFRIGERATOR          Photo               Ll o oo                                     Commercial brand Haier  Product description REFRIGERATOR  Type of Appliance  FS  freestanding       built in  FS  Energy efficiency class A  Climate class  N    18 32   C T   18 43   C  N  Freezer compartment   Star rating   Gross capacity   277  Total net capacity l 213  Defrosting  H manual A automatic  Fridge Freez H  Defrost water outlet           circulating ventilator Yes  Kind of coolant  R134a R600a  R600a  Foaming components C P          Colours  see L      Voltage   frequency V Hz 220 240 V   50  Input power   mains fuse minimum W A 100W 0 5A  Temperature range  from gt to  Fridge   Freez   C 0 10  C    lt  18  C                Top cover White  Cabinet White  Door Frame White  Fascia panel   Handle White       Inside door  drawers    Door            w white t transpar      F  Flat   R  Rounded   S  Streamline                               Hinged  r  right    left    reversible  r   reversible   Lock Cyes not  No  Drawers  CRISPER    Number n   1  Crisper     Salad crisper s     Control Panel     transparent   white     t                             Thermometer interior   exterior interior  Control lamps green   yellow   red    Over temperature ALARM LED   acoustic    Adjustable thermostat Yes  Fast freeze switch    Interior light W YES  Adjustable feet front   rear n   front  Castors front   rear                  10     Unit dimensions H W D cm
26. normal       If 1 mechanical refrigerator  change the tache of display  to overhaul of thermostat   1 If the compressor starts when switch of fast freezer is  open  it Hthe complaint of thermostat    2  Adjust the thermostat properly  3 Temperature induction probe placed properly  4 Temperature induction loose or desquamate             Adjust grate of thermostat    Temperature  gt 30  C    16 30 C    lt 16    refrigeration 0 10  C  freezer  16     24    soft freezer  3     7    1   3 grade  3   Sgrate  5   7 grate            Unitary poor    cooling cooling             efrigeration normal  cooling    efrigeration poor  cooling                  isplay sectio  for freezer appear  F1 or F3    aintain technics o  sensor        Enclosed bar of  refrigeration broken        Repair the Enclosed bar             f 7    Croom norma  cooling       Freezer poor  cooling    isplay section for  freezer appear F4           sensor    enclosed bar of freeze  gap or broken       isplay section for  reezer appear 82       enclosed bar of freezer  gap or broken    Repair the Enclosed bar    aintain technics o    Repair the Enclosed bar                                      aintain technics  of sensor    Sincere Forever       Haier Group  Tel 86 532 88938356  Web site http   www haier com    
27. ostat cannot be released    REMEDY   Dismantle the thermostat and make a through checkup  if it is totally out of functioning  replace it with a  new one    3  evaporation temperature is too high in  refrigerating system  resulting in lower refrigerating  capacity and hence continuous running of compressor   ANALYSIS OF TROUBLE   Leakage of refrigerant and clogging in a refrigerating system will directly affect its refrigerating capacity   Due to the reduction in its refrigerating capacity  the refrigerator temperature cannot reach its rated  value  the thermostat won t work  thus the compressor runs continuously  When the evaporation  temperature in the system is too high  the temperature sensing agent in the temperature sensor is also  hotter  therefore  the thermostat is unable to cut off the power supply to the compressor and stop it   REMEDY   If it has been found that the refrigerant in the system is insufficient in quantity  recharge it with  refrigerant  In case clogging occurs  disassemble the part where it is blocked  If the evaporation  temperature is too high  settle this problem with an appropriate quantity of refrigerant    4  No stoppage of compressor due to damaged heat insulation layer inside case body and or door  seal   ANALYSIS OF TROUBLE   When the heat insulation layer inside the case body deteriorates or the door seal is not closely  touches the door frame  the temperature in the refrigerator will rise and makes the compressor running  continuously    R
28. ower  than the saturation pressure corresponding to the same ambient temperature     REMEDY   In case there is leakage of refrigerant from the system  do not hurry to recharge it with  refrigerant  manage to find out leak points immediately  and make a note of from where it leaks     welding points and parts  After having them repaired  recharge refrigerant   There are so many joints  and sealed surfaces in a refrigerator  accordingly  quite a lot potential leak points do exist in the  system  In troubleshooting  pay attention to those parts that are liable to leak  check main connection  points for oil seepage and tubing for cracks  If there is no severer leak point  charge the system with  nitrogen and detect leak points with the commonly adopted method  repair them  evacuate  charge the  system with refrigerant  and then turn on the refrigerator to make a test run    2  Too much refrigerant charged into the system  ANALYSIS OF TROUBLE      In case the amount of refrigerant charged into the system exceeds its nominal capacity  the  superfluous refrigerant will of course take some space of the evaporator  thus reducing its  heat dissipation area and hence the refrigerating efficiency of the system  The abnormal phenomena  caused by this reason are as follows  the gas suction and exhaust pressures are generally higher than  their respective normal values  the temperature of its condenser is higher and the electric current of  the compressor rises  loose frost forms on the eva
29. porator  the refrigerator temperature drops  slowly  and frost appears on the gas return tube     b  In case excessive refrigerant has been charged  the liquid refrigerant that cannot evaporates in the  evaporator will return to the compressor  and thus a phenomenon of  liquid striking  will occur  The  liquid refrigerant evaporates and effervesces as soon as it flows into the refrigerating oil at the  bottom of compressor  If the condition is severe  foams will fill all over inside the compressor housing  and be sucked by the piston  causing damage to the components of compressor     REMEDY  ccording to the operating procedures  it is mandatory to turn the machine off  and everal minutes  later  open the refrigerant charging tube and let the refrigerant escape om it  replace the dry    filter  recharge refrigerant after evacuating  and then seal the harging port    3  There is air left in the refrigerating system  ANALYSIS OF TROUBLE  residual air in the refrigerating system will reduce its refrigerating efficiency  The rominent phenomena  are the increase in its gas suction and exhaust pressures however  the gas exhaust pressure will not  exceed its rated value   obvious increase in emperature in the segment from the compressor outlet to  the condenser inlet  Because here is air in the system  both the gas exhaust pressure and temperature  will rise  and oreover  the gas flowing sound is intermittent and obviously louder    REMEDY  After shut down for several minutes  open 
30. pped with a  transparent ice layer  and finally the temperature in the refrigerator cannot drop down to the prescribed  range    REMEDY  turn the refrigerator off and make preparations for defrosting  open the refrigerator door to let the air  come in  or use a fan to speed up air flowing so as to shorten the time needed for defrosting  Never  strike the frost layer with any iron tools or wood stick in order to avoid damage to the evaporator  tubing    6  Refrigerating oil left in evaporator tubing  analysis of Trouble  During the process of refrigerating cycles  a little refrigerating oil may remain in the evaporator  tubing  and after a longer time of operation  if there is considerable refrigerating oil left in the  evaporator  the heat conduction effect will be severely affected  thus causing a poor refrigerating  effect      REMEDY   It is quite difficult to determine whether this trouble is caused by the refrigerating oil left in the  evaporator tubing  because this kind of phenomenon and other several trouble are tends to be  confused  Generally speaking  you can make a judgment based on the frost formed on the  evaporator  If the frost does not cover the evaporator   and moreover it is loosely formed  you can  make a judgment that the deterioration of refrigerating effect is due to the accumulation of refrigerating  oil left in the evaporator tubing in case no other troubles have been found   To clear off refrigerating oil  left in the evaporator  dismantle the evapor
31. rt circuit occurs or the resistance of a certain phase  is low  this means that short circuit does exist in the windings and or between turns  and insulation  layers have been burned or deteriorated  A megameter can be used in this inspection  too    f the  insulation resistance is lower than 2M   this means that the insulation layer is already breakdown  If the  motor has been burned  repair it or replaced it with a new one    b  Fault of control relay   ANALYSIS OF TROUBLE   Overheat  burnout or wear of control relay contacts may occur generally  All these will cause poor  contact in electricity    REMEDY   Dismantle it to repair  or replace it with a new one    c  Poor electric contactor in thermostat   ANALYSIS OF TROUBLE   Burnout of contactor and leakage of temperature sensing agent may occur generally    REMEDY   Replace the old with a new one    d  Check the terminals for loose connection and electric circuits for other abnormal phenomena    5  Mechanical faults of compressor   a  Seizing of shaft   This phenomenon is caused mostly by poor lubrication  such ad insufficient quantity of lubricant   clogging in the lubricant oil line  or intermittent lubricant oil supply  Dirt and other impurities in the  lubricant oil will increase its viscosity and cause the shaft to be seized  Copper plating may also result  in seizing of shaft    b  Seizing of piston   This is caused by too small fit clearance between the piston and cylinder or expansion due to heat   Judgement of se
32. sorbers  such as silica gel  anhydrous  calcium chloride  to the refrigerating system so as to filter out the moisture from the system  then  replace the filter  evacuate it again and   finally charge the system with refrigerant    b  Clogged with dirt in capillary   ANALYSIS OF TROUBLE   The capillary inlet is a place where coarse grained dirt or refrigerant oil in the system will tend to settle  down and clog it  In case considerable dirt accumulates there  the whole filter screen may be blocked  totally  making the refrigerant unable to go through  Clogging with dirt exhibits the same symptoms as  that with ice  namely  higher gas suction pressure  lower temperature of discharged gas  and no gas  flowing sound from the evaporator  The difference between the both is as follows  if the clogging is  caused by dirt   tapping the suspicious clogged point  generally in the capillary or the connection joint  of the filter  may cause the refrigerant to flow through partially  resulting in some corresponding change   whereas in that case if you heat it with a hot towel  no reaction will happen  no flowing sound can be  heard  moreover  there is no periodic change  After rejecting the possibility of ice clogging  it can be  generally considered as the clogging due to dirt     REMEDY   Dismantle the system  remove the dry filter from it  purge the tubing with nitrogen  install a new filter   then evacuate it and finally charge it with refrigerant    C  Clogging in filter   ANALYSIS O
33. the tubing  evacuate it and then recharge the System with  refrigerant    4  Low efficiency of compressor  ANALYSIS OF TROUBLE  Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharge  Capacity  and hence the corresponding reduction of refrigerating capacity  under the Condition that the  refrigerant in the system is unchanged  This phenomenon occurs mostly When the compressor has  been used for quite a long time  its moving parts have worn to a Considerable degree  fit clearance  between various parts have increased and sealing Property of its gas valve has deteriorated  resulting  in an decrease in its actual gas Discharge capacity    METHODS OF JUDGMENT  Measure the high and low pressures with pressure gauges to see whether they are Normal  If an  abnormal sound comes from the compressor or the temperature of its Causing is too high  Cut the  discharge port open and operate the compressor  feel it if There is pressure at the discharge port with  your finger  For a normal compressor  its Discharge port is difficult to be blocked with your finger if you  just apply a little effort    5  Too thick frost layer formed on evaporator  ANALYSIS OF TROUBLE   If a direct cooling refrigerator is to be used for a prolonged period of time  be sure to defrost its  evaporator regularly  if you fail to do so  the frost layer on the evaporator tubing will become thicker  and thicker  Heat conduction will be severely affected when the whole tubing is wra
34. und produced by the normal circulation of refrigerant within the evaporator  In case only the  gas flowing sound can be heard and there is no water flowing sound  this indicates that the refrigerant  has already percolated  If neither the flowing sound nor the gas sounds from the evaporator can be  heard  this means that the filter or capillary has been clogged      3 Touch and Feel  a  Feel the compressor when running  its temperature should be generally less than 90  C in the    normal state  it may exceed 90      in case of running for a longer period of time      b  After the compressor has operated normally for 5 10 minutes   ouch and feel the condenser  the  temperature of its upper part should be higher than that of its lower part  or its right part is hotter than  its left part  depending on the type of condenser coil   this indicates that the refrigerant is circulating   If  the condenser is not hot  this means the leakage of refrigerant      case the condenser radiates heat for  only several minutes and then cools down  this means that the filter and capillary have been  clogged  As for the forced air cooling condenser  hot air will be blown out of it  this means that the  system is out of order         Feel the filters temperature  During the normal operation of refrigerating system          temperature on the filter s surface should be a little higher than the ambient temperature  if you touch it  with your hand  you will have a sense of slight heat      case dew 
35. yzed  below     1  All refrigerant in the system has leaked out   ANALYSIS OF TROUBLE   Leak points in the refrigerating system have not been found and repaired timely  thus resulting in the  total escape of refrigerant  There are two kinds of leakage 21  slow leakage for instance when we want  to use a refrigerator that has been put out of quite a long time  we find the leakage of refrigerant  or in  the course of its operation  we have found that the refrigerator is gradually becoming not so cold and  finally no refrigerating cab be achieved   ii  fast leakage in that case  all the refrigerant will escape  swiftly due to abrupt rupture of system tubing     Symptoms of total leakage of refrigerant are mainly as follows   the compressor can be started easily   if there is no damage to the compressor parts  and its operating current becomes low  its gas suction  pressure is high and discharge pressure is lower  the gas discharge tube feels rather cold  no sound of  gas eruption from the liquid in the evaporator can be heard  and no will gush out of the process tube if  you cut it open after shutdown     REMEDY   Check the whole machine   particularly those locations which are liable to leak  After leak points have    been found  repair them or replace them with new parts according to specific circumstances  then  evacuate the system and finally charge refrigerant    2  Refrigerating system has been clogged   a  Clogged with Ice   ANALYSIS OF TROUBLE   The dryness treatment for
    