Home
        SERVICE MANUAL
         Contents
1.  a little refrigerating oil may remain in the  evaporator tubing  and after a longer time of operation  if there is considerable  refrigerating oil left in the evaporator  the heat conduction effect will be severely  affected  thus causing a poor refrigerating effect     It is quite difficult to determine whether this trouble is caused by the refrigerating oil left in  the evaporator tubing    because this kind of phenomenon and other several trouble are  tends to be confused  Generally speaking  you can make a judgment based on the frost  formed on the evaporator  If the frost does not cover the evaporator   and moreover it is  loosely formed  you can make a judgment that the deterioration of refrigerating effect is  due to the accumulation of refrigerating oil left in the evaporator tubing in case no other  troubles have been found   To clear off refrigerating oil left in the evaporator  dismantle the  evaporator  purge it thoroughly and then dry it  In case it is difficult to dismantle it  charge  refrigerant from the evaporator inlet to wash it several times  then purge and dry it with  nitrogen     7  Flowing obstructed in refrigerating system   Analysis of Trouble   Because the refrigerating system was originally not purged thoroughly  some of the filter  screen meshes have been clogged by dirt accumulated in the filter after using it for a  certain time of period  thus resulting in a decrease in flow rate  and hence a poorer  refrigerating effect     The abnormal pheno
2.  and tubing for  cracks  If there is no severer leak point  charge the system with nitrogen and detect leak  points with the commonly adopted method  repair them  evacuate  charge the system with  refrigerant  and then turn on the refrigerator to make a test run         2  Too much refrigerant charged into the system   Analysis of Trouble   a  In case the amount of refrigerant charged into the system exceeds its nominal  capacity  the superfluous refrigerant will of course take some space of the  evaporator  thus reducing its heat dissipation area and hence the refrigerating efficiency  of the system  The abnormal phenomena caused by this reason are as follows  the gas  suction and exhaust pressures are generally higher than their respective normal  values  the temperature of its condenser is higher and the electric current of the  compressor rises  loose frost forms on the evaporator  the refrigerator temperature drops  slowly  and frost appears on the gas return tube     b  In case excessive refrigerant has been charged  the liquid refrigerant that cannot  evaporates in the evaporator will return to the compressor  and thus a phenomenon of     liquid striking    will occur  The liquid refrigerant evaporates and effervesces as soon as it  flows into the refrigerating oil at the bottom of compressor  If the condition is  severe  foams will fill all over inside the compressor housing and be sucked by the  piston  causing damage to the components of compressor     Remed       A
3.  insulation has deteriorated due to being affected with damp  thus resulting in slight  electric leakage    2  Serious electric leakage   Refrigerator case has become live due to faults occurred in some electric devices or the  erroneous wiring in installing power cord plug or outlet by the user  This is very dangerous   3  Electric leakage test   a  Slight electric leakage   A tingle sense will be experienced as soon as you touch the metal parts of the refrigerator  with your hand  When you test them with a test pencil    its neon lamp will come on  In that  case  the first thing you need to do is to determine whether the grounding is perfect  If the  grounding is no problem  turn off the refrigerator immediately    then check the insulation of  electric circuits with an avometer     b  Serious electric leakage   Never touch the case body of the refrigerator  its door handle or other metal parts with  your hand  Test the refrigerator with a test pencil  it will light up intensively  measure the  resistance between the power cord plug and the case body with an avometer  the reading  will be zero  0Q   in the worst case  the fuse will be blown  Check the 3 prong outlet to see  whether the live wire and the null line are inversely connected  this makes the ground  protection lead out from the power cord plug being connected to the live wire  Another  possibility is that the live wire and null line of the outdoor power supply circuit have been  inversely connected accordingly  t
4.  of  order  ii  the control system works normally  and there are troubles in the refrigerating  system or other parts    1  Temperature is set improperly   a  The temperature control knob is set to the    coldest    position  This position is to be used  for fast freezing or continuous running  its temperature for power off is too low  therefore   the compressor won t stop and the temperature in the refrigerator becomes lower and  lower     b  Inspection method  check the temperature control knob to see whether it is set in the  position    coldest       2  Thermostat is malfunctioning and makes the compressor running continuously  Analysis of Trouble   When the thermostat doesn   t work normally  it will make the compressor run continuously   and hence very low temperature will be achieved in the refrigerator  The fault is generally  due to the fact that the contacts of the thermostat cannot be released    Dismantle the thermostat and make a through checkup  if it is totally out of functioning   replace it with a new one    3  evaporation temperature is too high in refrigerating system  resulting in lower  refrigerating capacity and hence continuous running of compressor   Analysis of Trouble   Leakage of refrigerant and clogging in a refrigerating system will directly affect its  refrigerating capacity  Due to the reduction in its refrigerating capacity  the refrigerator  temperature cannot reach its rated value  the thermostat won t work  thus the compressor  runs continuo
5.  to repair  or replace it with a new one    c  Poor electric contactor in thermostat    Analysis of Trouble    Burnout of contactor and leakage of temperature sensing agent may occur generally   Remedy   Replace the old with a new one    d  Check the terminals for loose connection and electric circuits for other abnormal  phenomena    5  Mechanical faults of compressor   a  Seizing of shaft   This phenomenon is caused mostly by poor lubrication  such ad insufficient quantity of  lubricant  clogging in the lubricant oil line  or intermittent lubricant oil supply  Dirt and other  impurities in the lubricant oil will increase its viscosity and cause the shaft to be seized   Copper plating may also result in seizing of shaft    b  Seizing of piston                This is caused by too small fit clearance between the piston and cylinder or expansion due  to heat    Judgement of seizing shaft and piston After the refrigerator has been powered on  the  compressor will not start and run  but a slight hum sound can be heard  and several  seconds later  thermal protective relay will actuate and make the contacts open  this  process will occur repeatedly  but the compressor cannot be started    E  Compressor won   t stop   Sometimes  the compressor will run continuously for several hours or run without end   If  the food placed in the refrigerator is not too much  there may be the following two  situations  i  the refrigerator very low  this means that the control system is probably out
6. CAUTION    READ THIS MANUAL CAREFULLY TO  GC      DIAGNOSE TROUBLE CORRECTLY  BEFORE OFFERING SERVICE    Refrigerator    SERVICE MANUAL       MODEL  HF 113A       Features   1 Optimized condensing system   2 Direct cooling single system refrigerator     Haier Group    Part1 Specifications                                                    photo  Family type Europe style  Type of appliance  FS   free standing  FS   BI   built in    Supplier own brand Haier  Suppliers bar code   Energy efficiency class A  Climate class SN 10 32  C  N 16 32  C    ST 18 38  C  T 18 43  C    SANSI  Freezer compartment star rating Ki  Gross capacity  Total net capacity 83L  Net capacity refrigerator compartment  Net capacity freezer compartment    total    Net capacity adjustable temperature   drawer  Freezing capacity   24 hours kg 24 h 10kg 24 h  Energy consumption   year kWh year 200 75  Energy consumption  EN153  per 24 h kWh 24 h 0 55  Max noise level dB A  42  Max storage time by power failure   Freezer  Foaming components  R141b   R134a   PU Cyclopentane   C P   C P   Approvals  VDE   T  V   IMQ   NF   OVE     DEMKO etc     Certifications   CE   ISO 9001 2   LGA  GS CE   3    Keyfeatures    Cooling system   K   K   Compressor   A   Absorbtion    Number of compressor s  n   1  Defrosting Fridge   Freezer   M manual A automatic           Control system    M   Mechanical   Fuzzy logic  NO FROST   Fridge Freezer   Ventilated   Fridge only   Antibacteria system     E   Electronic        External 
7. alue in the direction of the lower  temperature graduation  then check the contacts to see whether they are closed  If they  are still not closed  dismantle the temperature sensing disc and then immerse it into warm  water to see whether the contacts actuate  if not  it can be preliminarily determine that  temperature sensing agent has leaked out  and it must be replaced with a new thermostat   4  Motor troubles and other electric faults   a  Motor windings have been burned or short circuited between turns   Analysis of Trouble   When motor windings have been burned or short circuited between turns  the fuse will be  blown repeatedly  and the blowout occurs particularly at the instant when you close the  knife switch    Check the terminals and the outer casing to see whether they are short circuited  and  measure the resistance of each phase with an avometer  If short circuit occurs or the  resistance of a certain phase is low  this means that short circuit does exist in the windings  and or between turns  and insulation layers have been burned or deteriorated  A  megameter can be used in this inspection  too    f the insulation resistance is lower than 2  MQ  this means that the insulation layer is already breakdown  If the motor has been  burned  repair it or replaced it with a new one    b  Fault of control relay   Analysis of Trouble   Overheat  burnout or wear of control relay contacts may occur generally  All these will  cause poor contact in electricity    Dismantle it
8. ame symptoms as that with ice  namely  higher gas suction pressure   lower temperature of discharged gas  and no gas flowing sound from the evaporator  The  difference between the both is as follows  if the clogging is caused by dirt   tapping the  suspicious clogged point  generally in the capillary or the connection joint of the filter  may  cause the refrigerant to flow through partially  resulting in some corresponding change   whereas in that case if you heat it with a hot towel  no reaction will happen  no flowing          sound can be heard  moreover  there is no periodic change  After rejecting the possibility  of ice clogging  it can be generally considered as the clogging due to dirt     Dismantle the system  remove the dry filter from it  purge the tubing with nitrogen  install a  new filter  then evacuate it and finally charge it with refrigerant    C  Clogging in filter   Analysis of Trouble   Total clogging of a filter is rarely to occur  This trouble is mostly caused by the paste like  matter formed from the substances filled into the system or other dust after the refrigerator  has been used for a longer time  or by the dirt accumulated gradually inside the filter   Sometimes  tapping the filter nay cause a passage for flowing  Touching it with your hand   you will feel that it is cooler compared with its temperature in the normal state    The same as described in the capillary clogging with dirt    3  Troubles of Compressor   a  Breakage of gas suction and di
9. as valve has deteriorated  resulting in an decrease in its actual gas  discharge capacity     Methods of Judgment   Measure the high and low pressures with pressure gauges to see whether they are  normal  If an abnormal sound comes from the compressor or the temperature of its  causing is too high  Cut the discharge port open and operate the compressor  feel it if  there is pressure at the discharge port with your finger  For a normal compressor  its  discharge port is difficult to be blocked with your finger if you just apply a little effort     5  Too thick frost layer formed on evaporator   Analysis of Trouble   If a direct cooling refrigerator is to be used for a prolonged period of time  be sure to  defrost its evaporator regularly  if you fail to do so  the frost layer on the evaporator tubing  will become thicker and thicker  Heat conduction will be severely affected when the whole  tubing is wrapped with a transparent ice layer  and finally the temperature in the  refrigerator cannot drop down to the prescribed range     Turn the refrigerator off    and make preparations for defrosting  open the refrigerator door  to let the air come in  or use a fan to speed up air flowing so as to shorten the time needed  for defrosting  Never strike the frost layer with any iron tools or wood stick in order to avoid  damage to the evaporator tubing     6  Refrigerating oil left in evaporator tubing    Analysis of Trouble                   During the process of refrigerating cycles 
10. ccording to the operating procedures  it is mandatory to turn the machine off  and  several minutes later  open the refrigerant charging tube and let the refrigerant escape  from it    replace the dry filter  recharge refrigerant after evacuating  and then seal the  charging port     3  There is air left in the refrigerating system   Analysis of Trouble   Residual air in the refrigerating system will reduce its refrigerating efficiency  The  prominent phenomena are the increase in its gas suction and exhaust pressures   however  the gas exhaust pressure will not exceed its rated value   obvious increase in  temperature in the segment from the compressor outlet to the condenser inlet  Because  there is air in the system  both the gas exhaust pressure and temperature will rise  and  moreover  the gas flowing sound is intermittent and obviously louder     After shut down for several minutes  open the tubing  evacuate it and then recharge the  system with refrigerant     4  Low efficiency of compressor   Analysis of Trouble   Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharge  capacity  and hence the corresponding reduction of refrigerating capacity  under the  condition that the refrigerant in the system is unchanged  This phenomenon occurs mostly  when the compressor has been used for quite a long time  its moving parts have worn to a  considerable degree  fit clearance between various parts have increased and sealing  property of its g
11. ce can correctly  locate them and take reasonable remedy measures based on their comprehensive  analysis of trouble characteristics as well as operating conditions for various kinds of  refrigerators    Three Essentials for Checkup  1  Look   a  Check the tubing of refrigerating system for cracks and various welding points for  leaks  if leakage occurs  an oil stain can be seen definitely    b  Check the suction and exhaust pressure values  high pressure and low pressure  of  compressor to see whether they are normal    c  Check the conditions of frost attached to its evaporator and gas return tube  It is  abnormal if frost has formed on part of the evaporator or there is no frost attached to it    d  Pay attention to the speed of temperature drop inside freezer compartment  It is  abnormal if the speed of temperature drop is obviously slower than the corresponding  normal speed    e  Check the environment to see whether it is suitable for placing a refrigerator     f  Check refrigerator door seal  case  table surface and heat insulation layer    g  Look at the main control board to ascertain if various indication states are normal     2  Listen   a  Listen to the noises produced when the compressor is running Hums from a fully  enclosed aggregate unit is the sound caused by overload indicating that the motor cannot  be started normally  meanwhile  a clattering sound can be heard from inside the start  relay  which is produced because the start contacts cannot be released nor
12. control display  Temperature range  from gt to     Super Cooling  Fridge   Super Freezing  Freezer   Stand by function  Holidays    ECO function   Over temperature alarm Red lamp      LCD LED   Acoustic    Adjustable thermostat   Control lamps   Green   yellow   red     Unit dimensions with out handle   H W D    Depth with open door   Net weight   Voltage   frequency    Input power   mains fuse  intensity     Door profile  F   fat   R   rounded   S  streamline   Handle  External Metal Integrated           Available colours    Fridge compartment     Shelves   Number  Total   adjustable   Type  gr grill   g glass    p plastic     Colour  w white  t transparent     Bottle holder   bottle s    Chiller compartment   drawer  Crisper s     Number   colour t   transparent  w            white    cm    cm  kg          below  18  C    505 572 850    572   31kg  220 240 V   50Hz   220    S    Integrated          Shelf  on salad crisper   g glass    p plastic   Door   Storage rack s   Total     Butter and cheese compartment   Type of rack s  g glass   p plastic   Inside colour   Reversible door   Lock   Self closure mechanism   Freezer compartment    Drawer s    Basket s    Flap s    Ice tray   Adjustable temperature drawer   Colour of drawer  w white   t transparent      Shelf  g glass  W wire   Door rack s   g glass    number p plastic     number   p plastic     Defrost water outlet    o    o    N fan   3  o    3 G                 RS     Interior light  fridge freezer  W 0  Special ice 
13. e evaporator  tubing  Because the pressure difference is still greater after the compressor has just  stopped running  the refrigerant will flow for a certain time   therefore  this sound is a  normal phenomenon  2  A click sound can often be heard from the refrigerator  This is a  normal sound produced by the pull in or release of the armature of a current deadweight  start relay when starting the compressor  The compressor motor will produce a slight  and uniform sound while it is running  This sound is not easy to be heard in the  daytime    but of course it can be heard distinctly at night  3   The compressor consists of an  electric motor and a compressing apparatus  During its normal operation    the motor   s  stator core and windings will rise to a temperature in the range of 100  C  110  C    and the  temperature of the piston and cylinder of the compressing mechanism can also reach as  above 100  C due to the heat produced when compressing refrigerant  Most of the heat  radiates to the air through the compressor casing  therefore    its casing is generally at a  temperature between 85  C  90  C it is very hot    particularly in summer when the ambient  temperature is higher  All these are normal phenomena   4  For the direct cooling  refrigerator  a kind of irregular crack sound can be often heard when the compressor is  running for a certain period of time or has just stopped its running  This sound is caused  by the stress relief due to expansion and contraction w
14. er input  and output voltage of main  ontrol board is norma          Main control board is out of work              Whether each  contact of main control board             is normal          Tighten each  contact and test machine  again       Compressor doesn    t start    between starting and stop  temperature  should pay    sometimes because the  temperature in case is    attention when do test          Adjustment of thermostat  Temperature of  environment     gt 30  C 1 3 grade  16 30  C 3 5grade   lt 16C 5 7grad          compressor  a slight and uniform hum sound due to undulation of electric current can be  heard generally    this is a normal phenomenon  However    if it sounds like     tong  tong        i e   an impact sound inside the compressor    this means that a large  quantity of wet vapour of refrigerant or refrigerating oil has come into the compressor  cylinder  if it sounds like    dang  dang        a striking sound of metal parts inside the  compressor  this means that some moving parts have loosened  note to differentiate this  sound from those formed during starting or stopping the compressor     b  Listen to the sound caused by the flowing of gas in the evaporator Open the refrigerator  door while the compressor is in operation  incline your ear and listen attentively the gas  flow sound inside the evaporator  If it sounds like gentle whistling accompanied by a  sound similar to water flowing  this is the sound produced by the normal circulation of  refrig
15. erant within the evaporator  In case only the gas flowing sound can be heard and  there is no water flowing sound  this indicates that the refrigerant has already  percolated  If neither the flowing sound nor the gas sounds from the evaporator can be  heard  this means that the filter or capillary has been clogged      3 Touch and Feel  a  Feel the compressor when running  its temperature should be generally less than 90  C  in the normal state  it may exceed 90  C in case of running for a longer period of time     b  After the compressor has operated normally for 5 10 minutes   ouch and feel the  condenser  the temperature of its upper part should be higher than that of its lower part  or  its right part is hotter than its left part  depending on the type of condenser coil   this  indicates that the refrigerant is circulating   If the condenser is not hot  this means the  leakage of refrigerant  In case the condenser radiates heat for only several minutes and  then cools down  this means that the filter and capillary have been clogged  As for the  forced air cooling condenser    hot air will be blown out of it   this means that the system is  out of order    c  Feel the filter   s temperature  During the normal operation of refrigerating system  the  temperature on the filter s surface should be a little higher than the ambient temperature  if  you touch it with your hand    you will have a sense of slight heat  In case dew condensation  appears due to the fact that its temp
16. erature is obviously lower than the ambient  temperature  this means that most meshes of its screen has been clogged   resulting in an  obstructed flowing of refrigerant  thus causing a drop in temperature due to throttling    d  Feel the temperature of exhaust gas from the refrigerating system  the exhaust gas  should be very hot and this is the normal working state  For those refrigerator with  enclosed type of compressor refrigerating system  no frost or dew drop will from on the  gas suction tube  otherwise  there is something wrong in the system  Frosting and dew  condensation may appear for a very short time period when just starting the machine  this  is a normal phenomenon    Because a refrigerator is a combination of several  components  they are related and have influence on each other  In case an abnormal  phenomenon has been found through the above mentioned checkups  you need not to  make a hasty conclusion based on only one abnormal phenomenon  It is advisable to find  out two or more abnormal phenomenon  or conduct troubleshooting comprehensively with  the aid of instruments or other ways  because several kinds of troubles may share a    common abnormal phenomenon  and two or more abnormal phenomena may occur  simultaneously due to a certain trouble  With this method  you can reject some suspicious  troubles and finally make a correct judgment      Part 5  Analysis of Troubles and Troubleshooting    A  Poor Refrigerating Effect  The so called    poor refrigerat
17. hat case  all the refrigerant will escape swiftly due to  abrupt rupture of system tubing         Symptoms of total leakage of refrigerant are mainly as follows   the compressor can be  started easily  if there is no damage to the compressor parts  and its operating current  becomes low  its gas suction pressure is high and discharge pressure is lower  the gas  discharge tube feels rather cold  no sound of gas eruption from the liquid in the evaporator  can be heard  and no will gush out of the process tube if you cut it open after shutdown    Check the whole machine   particularly those locations which are liable to leak  After leak  points have been found  repair them or replace them with new parts according to specific  circumstances  then evacuate the system and finally charge refrigerant    2  Refrigerating system has been clogged   a  Clogged with Ice   Analysis of Trouble   The dryness treatment for the major parts in the refrigerating system has been performed  improperly  the effect of air purging for the whole system is not good  or the water content  in the refrigerant is out of standard  all these will cause the expansion valve to be clogged  with ice  The symptom for this trouble are as follows  the refrigerator sometimes can  refrigerate and sometimes cannot  the refrigerator compartment works normally at the  beginning  but after working for a certain period of time  frosting begins at the clogged  position  evaporation temperature reaches below 0  C  water wil
18. hen temperature changes  and will  not affect the normal application of refrigerator      4  3 Common Troubles in Refrigerators and Their Remedies    Causes for troubles occurring in refrigerators are closely related to the quality of  components and workmanship in assembling by manufacturers as whether refrigerators  are properly used and maintained  The parameters generally used to express the working  conditions of a refrigerator include the temperature inside the refrigerator  operation  rate    electric power consumption  noise level  and other functional indexes  If any one of  these parameters is beyond its permissible range  this indicates that there is a fault or  trouble in the refrigerator   During the whole service life of a refrigerator  the probability of  troubles occurring within a union time is called its failure rate  Making a comparison  between the control circuit system of a refrigerator and its refrigerating system  we can  find that the failure rate of the former is higher  and that of the thermostat is the highest   In  troubleshooting  the first thing you must do is to determine where the trouble comes from      the control system or the refrigerating system  There is general no trouble indicating  instrument mounted on the domestic refrigerator  locations and natures of troubles should  be determined according to their respective features  therefore  experience in servicing is  very important to troubleshooting  Service technicians with rich experien
19. his makes the null line become a live wire     G  Stronger vibration and loader noise   1  Refrigerator placed improperly   a  Uneven ground   Uneven ground will cause the refrigerator to be placed unsteadily  causing stronger  vibration and noise during its operation     b  Leveling screws not properly adjusted   If the leveling screws on refrigerator legs have not been adjusted properly  vibration and  noise will still occur even if the refrigerator has been placed on a level ground     2  Abnormal noise from compressor    Sincere Forever       Haier Group  Tel 86 532 88938356  Web site http   www haier com    
20. ing effect     refers to the fact that the refrigerator can operate  and refrigerator normally    but the temperature in the refrigerator cannot drop to the  prescribed value under the stipulated working conditions  In view of there are many  causes for this phenomenon  we are going to discuss and analyze it in the following 7  aspects     1  Leakage of refrigerant   Analysis of Trouble   The leakage of refrigerant in the system will result in an insufficient refrigerating  capacity  the resulting phenomena are its lower gas suction pressure and exhaust  pressure as well as higher exhaust gas temperature  The exhaust tube feels rather  hot  and a continuous gas flowing sound louder than usual can be heard at the outlet of  the capillary  and no frost or a smaller quantity of loose frost appears on the  evaporator  After shut down  the balance pressure in the system is usually lower than the  saturation pressure corresponding to the same ambient temperature     In case there is leakage of refrigerant from the system  do not hurry to recharge it with  refrigerant manage to find out leak points immediately    and make a note of from where it  leaks    welding points and parts  After having them repaired  recharge refrigerant    There are so many joints and sealed surfaces in a refrigerator  accordingly  quite a lot  potential leak points do exist in the system  In troubleshooting  pay attention to those parts  that are liable to leak  check main connection points for oil seepage
21. is of Trouble   In case the compressor cannot be started  this will generally exhibit in the power supply  circuit  for instance  power failure  poor contact of switch  and blown fuse  Make a  comprehensive analysis of these phenomena  fine out its real cause and take correct  measures to remove this trouble    a  Check the input power circuit to see whether where is voltage of the power supply   namely  the circuit which is connected to the knife switch  This can be determined with an  avometer or a test pencil  If a blown fuse is found  ascertain and remove its cause  then  replace it with a new one of the same specifications    b  Check the compressor accessories  including its thermal protector and relay  In case  the thermal protector is damaged  the compressor cannot be powered on  If the relay is  out of order  the motor will not run and hum sound can be heard from it after the  compressor is turned on  in that case  shut it down immediately  otherwise  the motor  windings will be burned out in case this condition lasts longer    c  Check the relay contacts and plugs to see if they are perfect and work reliably  Poor  contact may cause the motor not running or humming    2  Check the circuit voltage to see whether it is normal    Analysis of trouble   If the circuit voltage is obviously lower than its rated value  it will be difficult to start the  motor  and a hum sound can be heard from it    Measure the voltage with a voltmeter  if it is really too low  give directi
22. l accumulate at the narrow  part of the capillary and clog it gradually  then frost begins to melt at the evaporator  no  gas flowing sound can be heard  and the gas suction pressure assumes a state of  vacuum  Note that these phenomena will appear intermittently   sometimes the  refrigerator works well  and sometimes not well  In order to determine whether it is  clogged with ice  heat the suspicious points with hot water to make ice melt  and after a  while if a gas flowing sound resulting from an abrupt gush is heard and the gas suction  pressure rises as well  it can be confirmed that the trouble is caused by ice clogging     If there is too much moisture in the refrigerating system  it is advisable to release the  refrigerant  purge the tubing with nitrogen  and then charge the system with the filtered  refrigerant  However  the commonly adopted method is to connect a filter with moisture  absorbers  such as silica gel  anhydrous calcium chloride  to the refrigerating system so  as to filter out the moisture from the system  then replace the filter  evacuate it again and  finally charge the system with refrigerant    b  Clogged with dirt in capillary   Analysis of Trouble   The capillary inlet is a place where coarse grained dirt or refrigerant oil in the system will  tend to settle down and clog it  In case considerable dirt accumulates there  the whole  filter screen may be blocked totally  making the refrigerant unable to go through  Clogging  with dirt exhibits the s
23. maker  T Twist  A    Automatic    Ice cube tray s  n   0  Eggs tray s    Total number of eggs  Adjustable feet  front   rear  n   n   2 0  Castors  front   rear  n   n   0 0  Wall spacer grid or distance holder  Flush back  Length of cable inch  plug cm 200   E E di    Packing dimensions  H W D  cm 525 579 865  Gross weight kg 33  40   Container load  40   HC Container load   as   Packing weight kg 2  Kind of coolant  R134a R600a  R600a 42g  Packing materials   Recycling symbols RS                   Polystyrene  06        Wood    Users instruction     languages              Europe          Part2 Refrigerating Principle    2 1 Schematic Diagram of Refrigerating Principle    1  Compressor  2  Condenser    3  Dry Filter    4  Capillary Tube    5  Evaporator       2 2 Brief Description of System Flow Chart   3 6 series is a direct cooling single system refrigerator which has a freezer compartment   When the refrigerator is just powered on  the refrigerant flows in the sequence   1  gt 2  gt 3  gt 4  gt 5     Part3  Circuit Diagram       A POWER PLUG B THERMOSTAT  C OVERLOAD PROTECTOR  D COMPRESSOR E PTC    Part4  Maintenance Service and Trouble Shooting    4 1 When the refrigerator does not get cold at all    No cooling     If compressor NO Check and repair according to  can run after it stop to     the section of  the compessor  run five minutes and doesn t work    give power   YES     If compressor Refrigerant  can run naturally and NO leak check and  temperature raising       
24. mally  A  whistling sound is caused by the high pressure gas flowing out of the crack of the  pressure tube inside the compressor  and clucks are the sound of striking after the  suspended spring inside the compressor has broken   During the normal operation of    4 4 The compressor doesn   t work       Compressor  doesn    t start             Y                   Whether lighting  and display system is  normal    N       gt      Trouble of lighting and display system                        Whether the  grade of thermostat is  on 0    Y       Adjust the grade according to fact                        Whether the  resistance of compressor is  infinite or O       Compressor is open circuit or short  circuit                              Whether the  starting current is  about 5A       Inner trouble of compressor                                    hether PTC starter  resistance between running jack  d starting jack is 16 50          If it is infinite or 0  then the starter is  out of work                         Measure whether  two ends of heat protector  is through    Heat protector is out of work                        Whether the finge       of multimeter swing to 0 quickly  and then swing back slowly  when measuring two            Capacitance is out of work    J0ssaduu09 mau e JO  abueYyD                         poles of capacitance         Whether       Compressor  ilpin is tight   contact          Insert again  electrify and test                is good                  Wheth
25. mena caused by this kind of slight clogging in the system are as  follows  the gas discharge pressure is lower  the temperature of discharged gas drops  down  the position clogged has a temperature lower than that in normal conditions  and for  a severe clogging  even dew condensation as frosting may appear     Purge the tubing  and after replacing the dry filter with a new one or clearing it  thoroughly  recharge the system with refrigerant and seal the charging port         B  No Refrigerating   The phenomenon that the compressor runs normally  but no frost  or only a little frost    appears on the evaporator  and the refrigerator temperature does not drop down is called     no refrigerating     There are many causes for this trouble and it is relatively complicated    too   In servicing  special attention to finding direct causes for this phenomenon  Three  main potential causes for this trouble are analyzed below     1  All refrigerant in the system has leaked out   Analysis of Trouble   Leak points in the refrigerating system have not been found and repaired timely  thus  resulting in the total escape of refrigerant  There are two kinds of leakage  l  slow leakage  for instance  when we want to use a refrigerator that has been put out of quite a long  time    we find the leakage of refrigerant    or in the course of its operation    we have found  that the refrigerator is gradually becoming not so cold and finally no refrigerating cab be  achieved   ii  fast leakage in t
26. ons to the user for  buying a stabilizer so as to step up the voltage  thus normal operation can be achieved   3  Check the thermal relay to see whether its contacts are closed     Analysis of Trouble                   Three suspended spring inside the compressor case are out of balance  and strike against  the case  moreover  the wear of compressor parts may cause noise sometimes     3  Resonance of tubing and loosening of parts   Improper and compact laying of tubes or the loosening of parts may cause vibration and  noise     4  Inspection method   To find the sources of noise  press the vibration spot with your hand while the refrigerator  is in operation and listen attentively whether the vibration becomes weaker or  vanishes  If the refrigerator has not been levelly placed    put a level meter on its top table  and adjust the leveling screws on its legs  In case noise occurs from the  compressor  strike different locations on the side surface of its case using a rubber  hammer or hand hammer with a wood block in between so as to determine whether  the suspended springs are out of balance or being seized      The contacts of thermal relay sometimes may be open due to the leakage of temperature  sensing agent from the temperature sensor    Remove the relay cover to check up its contacts  if they are open  this means that the  original setting is not properly set or temperature sensing agent has leaked out of the  temperature sensor  Try to turn the adjusting stem of this v
27. otor   Analysis of Trouble   Probably  too many things have been put into the refrigerator  and hence the thermal load  exceeds its refrigerating capacity   or in case the power supply voltage drops considerably   the current flowing through the motor will increase drastically making the thermal protector  actuate and the fuse blown   and hence the motor stops running  If the motor is still  running continuously in such a case   its windings will be burned out      Reduce the thermal load  pay attention to the variation in voltage of the power supply                 c  Abnormal thermal protection   Analysis of Trouble   The compressor current is within its normal range  but the thermal protector actuates  repeatedly    Replace the thermal protector with a new one    3  Sudden stoppage due to other causes   Normal Stoppage   Start and stop of the compressor is generally controlled by a thermostat   When the  temperature in the refrigerator reaches its desired value  the thermostat will shut down the  compressor automatically  Never take this normal operation as a trouble  care should be  taken to differentiate it from other real troubles in servicing    D  Compressor won  t start   In case the compressor cannot be started  you must find out the origins of this trouble  through checkup step by step  because probably there are many causes  including those  electrical and mechanical    1  Inspect the power supply to see whether it is connected to the compressor  circuit    Analys
28. repair charge  of condenser is refrigerant again   very low  YES  T    no When charging refrigerant we must    pipe EYE or dirty   notice to make refrigerant true  things change filter and change i g i    refrigerant again     4 2  Normal Phenomena   Not Troubles for Refrigerators    In a domestic refrigerator  there is not only a complicated electric control system  but  also a refrigerating system that is difficult to discern whether it is in a good working  condition  Both the systems are related and affect each other  If a certain part of a  refrigerator works abnormally  lis refrigerating efficiency will decrease  operation  properties will become unstable  or even it cannot be used normally for those serious  cases  Refrigerators are generally of larger volume  once troubles appear  to send them to  a service department is really a tough thing  if such is the case  the user will always be in  suspense    sometimes  normal phenomena will be erroneously regarded as  troubles  Therefore  before we deal with the topics of frequently occurring troubles of  refrigerators and their remedies  we should firstly give a brief account of some normal  phenomena which are not troubles  In case any one of such phenomena occurs  there is  no need to worry about it and the user can use it at total ease   1  When the compressor  of a refrigerator has just stopped running  a rumbling sound can be heard from inside its  evaporator  This is a sound caused by the flowing of refrigerant in th
29. scharge valve blocks   Analysis of Trouble   The compressor works by means of the opening and closing of gas suction valve and  discharge valve to suck and discharge the refrigerant  If the valve block is broken  the  refrigerant can not be discharged  and hence no refrigerating can be achieved    Method for making judgement   It is quite difficult to differentiate this trouble from others because they often have similar  symptoms  In repairing  firstly  hear attentively if there is some abnormal sound coming  from the compressor  sometimes   the broken pieces of valve block may strike against the  cylinder   and feel the compressor casing with your hand to ascertain whether it is too hot   this is also helpful to the troubleshooting  secondly  measure the pressures at the high and  low pressure ports of the compressor with pressure gauges  if the gas suction valve block  is broken  the suction pressure gauge pointer will swing violently and the suction pressure  is very high  whereas when the gas discharge valve block is broken   the discharge  pressure gauge pointer will swing drastically and the discharge pressure is very high  In  the both cases  stop the compressor at once  and if technique is available  open the  cylinder cover and check up the valve block  repair it  or replace it with a new one    C  Sudden stop of Compressor during Its Running   The cause of sudden stop of a compressor during its running is mostly that the gas  suction pressure and or discharge press
30. ure exceed their respective prescribed ranges   thus making a pressure operated protective relay shut off the power to the compressor  and stop it  In the following we discuss mainly the reasons for causing excessively high  gas discharge pressure and low suction pressure    1  Stoppage due to excessively high gas discharge pressure   A  Too much refrigerant charged into the system   Analysis of Trouble   The phenomenon  such as loose frosting and poor refrigerating effect  may occur if  excessive refrigerant has been charged into the system  Superfluous refrigerant will  occupy a certain space of the evaporator  thus reduce its heat dissipating area  and the                phenomenon of    liquid striking    may occur  too  Meanwhile  dew or frost condensation  may occur on the gas return tube  and the gas discharge pressure will obviously rise   when it reaches the threshold value  the protective relay will actuate and shut off the  power supply to the compressor    Open the tubing  re evacuate and then charge the system with a proper quantity of  refrigerant    b  Air left in the system   Analysis of Trouble   The residual air in the system will circulate together with the refrigerant in the system  The  major symptoms caused by this residual air is higher gas discharge pressure  higher  discharged gas temperature  the gas discharge tubing is considerably hot when you feel it  with your hand   and poorer refrigerating effect  Furthermore  the gas discharge pressure  will e
31. usly  When the evaporation temperature in the system is too high  the  temperature sensing agent in the temperature sensor is also hotter  therefore  the  thermostat is unable to cut off the power supply to the compressor and stop it    If it has been found that the refrigerant in the system is insufficient in quantity  recharge it  with refrigerant  In case clogging occurs  disassemble the part where it is blocked  If the  evaporation temperature is too high  settle this problem with an appropriate quantity of  refrigerant    4  No stoppage of compressor due to damaged heat insulation layer inside case body  and or door seal    Analysis of Trouble                When the heat insulation layer inside the case body deteriorates or the door seal is not  closely touches the door frame  the temperature in the refrigerator will rise and makes the  compressor running continuously    Check the heat insulation layer for its damaged parts  repair it to improve its  heat insulation property  If the door has deformed or the door seal is not tightly sealed  against the case body  repair them  respectively    5  Too much food is placed in the refrigerator  or is placed too densely  resulting in poor  ventilation or poor conditions for temperature sensing  and hence no stoppage of the  compressor    6  Too high ambient temperature  poorer ventilation and heat dissipation make the  compressor running without stop    F  Electric leakage of refrigerator   1  Slight electric leakage   Electric
32. xceed its normal value when the compressor has run for a period not too long  thus  making the protective relay actuate and bring to a stoppage    Check up how the air has been left in the refrigerating system  Generally  there are two  possibilities  one is that the air has been sucked into the system when repairing due to  carelessness  or it has not been purged out totally when evacuating the system  the other  is that there are leak points at the low pressure end of the refrigerating system  Leak  points appear mostly in those low temperature parts or assemblies  because the  evaporation temperature is lower for such low temperature devices  especially at the low  pressure end  it is easier for the air goes into the system  Once it has been ascertained  that air does exist in the system  you have to open the tubing  re evacuate it and then  charge it with refrigerant    2  Stoppage due to electric troubles   a  Thermostat is out of control   Analysis of Trouble   In case the thermostat does not work in its good order or its temperature sensor has not  been installed properly  frequent stoppage is also likely to occur    Remedy   Try to adjust the temperature sensor   s position until the compressor can be started and  stopped normally  If this cannot be achieved  and the stoppage still occurs repeatedly  it is  most likely that the mechanical parts or contacts are out of order  disassemble the  thermostat  make a thorough checkup and repair it    b  Overload of electric m
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Manuel d`utilisation (M98501F00)  Philips DVI to VGA adapter SWX2511  Inversor 150 watts - Manual de instruções  MODE D`EMPLOI - Shoppers Drug Mart  bricosergio - guida all`acquisto di macchine per il legno    DS-4000 Online Instructions (English)  Manual do utilizador do iPhone  fire alarm and detection system. The designer    Copyright © All rights reserved. 