Home

DIGIVIEW USER'S GUIDE V2.6

image

Contents

1. NE system 1 users from 1000 1998 are users in System 2 etc If You select a user from a table on the left side You can see it s location in Digiplex systems on top of the right half of the Manage User window o DigiView v2 6 Manage users g File Tools Errors Setup Windows About _ 5X Digi amp OBO 2 Sl AE C mm Current J Dean E User 998 i User 999 User 999 mf gf From panel To panel Control panel 2 User 1 w User name Mester Ur Hed arae U le 123400 _ User 1001 User 1001 W E User 1002 User 1002 Card code 075 65188 ff User 1003 User 1003 User access level 0 User 1004 User 1004 User schedule 0 ff User 1005 User 1005 User assignment _ User 1006 User 1006 Partition 9 Partition 13 _ User 1007 veer 1T Partition 10 Partition 14 User 1008 User 1008 REC E aai User 1009 User 1009 pee one User 1010 User 1010 2 Partition 12 z Partition 16 User 1011 User 1011 GE ae Luk ma MIE Master code Arm only User 1013 User 1013 4 Code only Code assign v Stay ar E User 1014 User 1014 Coe SRODA gn PSmy arm i User 1015 User 1015 Duress code Force arm i User 1016 User 1016 Bypass access Code follows keypad ass User 1017 User 1017 FE E User 1018 User 1018 aep ON V Access card enabled 4 Add tolerance window User 1019 User 1019 ser ser i User 1020 User 1020 Card can disarm Access code follows sch fi User 1021 User 1021 Extended d
2. panel settings and security systems in a graphical user friendly environment The end user can manage the entire system simply clicking the mouse Simple user friendly and easy to navigate security systems PREPARING DIGIVIEW The DIGIVIEW software offers a complete supervision of security systems to the users The software displays the system events in graphic mode and stores them in database The users can manage these systems depending on their authority After purchasing the CD the user has a software which runs in demo mode after installation This mode means full access to the software features Gncluding 4 DigiplexNE control panels and operation of maximum 15 minutes In order to use the software without limitation you have to register the software For the registration process see document DigiView registration process disabling the time limit Getting started LOGIN At the start of the program the login window appears In this window username and password must be given By default master authority username and password are demo demo In order to launch the Digiview software the SQL server must be running on some computer in the network If You have used the Check Digiview_4 software the checked server with password were entered in these fields so You do not need to change anything in the Login window just type the username password If You want to change or check database server settings manually click
3. 13 10 59 39 4 27 3 as Particio Auto arm engaged 2006 04 13 10 59 55 1 User code entered on Keypad 2 1 es part 2006 04 13 10 59 57 1 User Card access on door 2 Door2 2 1 es part 2006 04 13 11 00 03 1 User code entered on Keypad 3 2 es part 2006 04 13 11 00 04 1 User Card access on door 2 Door 2 3 2 es part 2006 04 13 11 00 38 4 27 3 as Partici System end of exit delay 2006 04 13 11 00 38 4 27 3 as Partici End of auto arm engaging 2006 04 13 11 00 38 4 27 3 as Partici System armed 2006 04 13 11 00 47 4 25 1 es Partici System is not ready 2006 04 13 11 01 01 4 25 1 es Partici System is ready 2006 04 13 11 01 31 4 25 1 es Partici System is not ready 2006 04 13 11 01 53 4 25 1 es Particio System is ready 2006 04 13 11 02 22 4 Module disconnected 2006 04 13 11 02 22 4 Software disconnected from ca 2006 04 13 11 08 59 0 Software logout b 2006 04 13 11 08 59 1 OBR Software disconnected from ca v eed 15 58 05 Event filter setup ATTENTION Using Empty log button will erase the whole event database Use the Export to txt file button to save the displayed events in txt format To exit the window click the Close window 14 The menu File Import DXF file An exists dxf file may be imported as floorplan Exit Quit the software Tools Login The software tries to connect to the configured panels through the configured COM ports Logout All of the communication to the panels w
4. DIGIVIEW USER S GUIDE Digi Viw TABLE OF CONTENTS INTRODUCTION POR nenneee emeentartceen ertser E Riemer rete er sner settee meee l PREPARING DIGIVIEW a nR tee etme Pers fers AO ac da 2 CEIVED SAITO LOGIN daw iP Wa AE W COO a 2 CUSTOMIZING plan drawing eee aaa 3 CUSTOMIZING ADELS ek O AR oO PA AAU od WA 6 DEN Z UDANE SONWATE USCIS onesna pni AA Zo Ac WE Akona 7 PREPARING PLANS EDIT WINDOW ue ueaa wawa owa a wawa aaa zaszaczacwae 9 USING THE DIGIVE W sud di RCA AOR O 11 DUMENGNCEN MIO Week KA EO 11 Wat hi e MCNOOFDlaAfzew a CEE AGE ia dc a 11 Partition t OIDAC ei nant oi wiedza 12 LOC WINGO cenia AH PA AW AO 12 Mandec Users WNI WA w E esha as cee at ose ween ade 12 TOS UCT WIN OW ssa NEAR CAO A GA 14 AAA CZ EEEE 15 PIECZE get eae nae et Laue AE eee Or ORA E E 15 MOOR id epee en ents spect id epee ent persian Sed gerne cena es Gaia 15 Eiro A RY 15 BO NO acsearle O NE ceria ciate ese EWIE 15 Wadon Sea R ecco as Acca at sean cae ae arash eee 15 INTRODUCTION DIGIVIEW is an surveillance software for online monitoring and management of DIGIPLEXNE security systems The software is developed by Pragma Informatics Ltd especially for DIGIPLEXNE security panels and accessories The purpose of DIGIVIEW is to provide the end user direct and full control over several security systems by a single computer The software is designed to operate on Microsoft Windows operating system DIGIVIEW displays control
5. blue Click the left mouse button on the partition button to select all zones on floorplan that are assigned to that partition To deselect all click the left mouse button again on the name Click the right mouse button on the partition label A menu appears In this menu user can monitor the status of the partition Full Arm Stay Arm Instant Arm Force Arm Disarm Log window The events appear right away as they occur User can scroll search among events If the last event has been selected the new events will scroll the event list and the last event that happened will be always placed in the last visible line of the log window If not the last event has been selected the event list window will not scroll when new event is added to the list Only the events that happened since the last starting of the DigiView will be available in this log screen Events that happened before can be reached only with the Log query window If You double click left mouse button on some event in this window a floor plan will jump to default view for the affected zone this view can be saved in Edit mode pencil icon in toolbar with the right click on the desired zone door If the event was nat affecting just one zone but a whole partition armed ready double click on the event will cause the floor plan would jump to position so all zones in floor plan that are assigned to the affected partition will be visible on screen and each zone icon will be
6. communication to each systems but after 15 minutes it will shut down To run the full program a registration code must be given To complete registration restart the software A toolbar appears with the partitions of the successfully connected control panels with the imported floorplan in background o DigiView v2 6 Map X g Fie Tools Errors Setup Windows About x Digi k OQ 2 BH ZLTO Cala Partitions Part 1 Midle Area 1 Right Area 2 Right Area 3 Right Area 4 Right Partition 1 left Partition 3 left PPE 1 es Partici is TIE I 14 24 02 Control panel 1 Part 8 Midle System is ready 14 24 02 Control panel 1 Part 8 Midle Partition trouble end 14 24 02 Control panel 1 Part 8 Midle End of zones tampered 14 24 11 Control panel 1 User code entered on Keypad 2 es partici 14 24 16 Control panel 1 Part 2 Midle System in exit delay u 14 24 23 Control panel 1 Part 2 Midle System armed 14 24 23 Control panel 1 Part 2 Midle System end of exit delay Floorplan with the successfully connected Panels You can toggle on of the log window and partition buttons with the two icons on the right side end of the 1con line lt gt DigiView v2 6 Map 7 File Tools Errors Setup Windows About Toggle buttons EEEH 55113 Buttons for toggling Log window and partition buttons Customizing labels Click on the Configuration icon a configuration win
7. dow will appear You can set up the Partition Zone User names in appropriate tab by clicking the Import names button for each labels group The program reads the names from panels at about 2 labels second speed In case of importing user names the procedure can take up to one hour 3996 user names The imported labels appear in a separate window O DigiView v1 7 Map e x Digiw OQ 9 Kj EE oO j J Partitions TER E Partition 1 Partition 2 Partition 3 Partition 4 Partition 6 Partition 7 Partition 8 Partition 9 Partition 10 Partition 11 Partition 12 Partition 13 Partition 14 Partition 15 Partition 16 e A E o Configuration fx j gt Imported partition names TER _ Module Partition Newname 1 1 es Bel ptet 2 2 es Bel pteto 3 3 as Bel pteto 4 4 es Bel ptet 5 5 s Beleptet j Partition 4 6 6 os Bel ptet 49 12 Partition 5 7 7 es Bel ptet Partition 6 8 8 as Bel ptet 12 Partition 7 Partition 8 Select all Deselect all Accept we a a a a a i 12 49 36 Time remaining 815 seconds fr ANGOL DIGIVIEW M Total Commander 6 0 n vtelen Paint o Digiview_4 Label import window In this window You can select each line by double click or use the Select all button The selected names get blue background After selecting those labels You want to use in Digiview software click on the Accept butt
8. elay card Can access armed door it User 1022 User 1022 Arming with card disabled v User 1023 User 1023 E User 1024 User 1024 User 1025 User 1025 lt gt M 9 50 11 Manage users window After the user s settings were uploaded You can edit the settings or change the name label for this user Each setting in this field corresponds to User options in Digiplex NE system For explanations please check the System manager manual for Digiplex NE systems In order to these changed settings and labels become valid You must download all to the live systems Naturally the settings and label are treated separately so You must download both same as for upload using two buttons next to Upload buttons for name and for settings To change the name of the user in DigiView software used in the event list use the Store in DB button next to user name field When You click on it the label that was entered in the User name field will be stored in database and this name will be used from that moment for all events that contain this user At the same moment this name will replace the previous one in the Current row of the table on left side of User manage window 13 Log query window o Click on the magnifier icon and a new window appears Use the checkboxes and roll down menus to configure the Log filter When all checkboxes are empty and You click on the Start button all logged events
9. ical presentation of the system Description Front door Adding a door To grab and move the Device Door Text use the left mouse button To move the whole floorplan click the left mouse button outside the devices Click the right mouse button on the device and a menu appears DigiView v2 6 Map g Fie Tools Errors Setup Windows About BX Digikw amp OO HPS BM Fu WINLOAD lt gt Digiview_4 6 alarmbox Paint ig Adddoorbox P Total Command tal DIGIYIEWUSER HU je 16 44 Device modification In this menu You can choose to delete the selected item from the plan to modify the settings zone label shape or to set the view as default zoom for this device Click on the Set as default zoom for this device and the program will save the current position and zoom to be displayed as default view for the selected zone When You click on some event in the log window that was affecting some concrete zone the screen will jump to the saved Default zoom view for that device After these operations the default settings have been configured the software is ready to use 10 USING THE DIGIVIEW Surveillance window Watching the floor plan The colours of the detector s icon indicate the status of the detectors VVVVV WV Zone closed normal state icon presented only Zone opened a green corner is blinking armed red background is added to the icon bypassed a yellow corner is bli
10. ill be stopped Configuration Switch to Configuration window Manage users Switch to Manage users window Surveillance Switch to Surveillance window Edit devices The floorplan editor window appears Show log Latched If ticked the Log displayed in the bottom of the screen If not ticked no log will be displayed Log query The log filter setup window appears Errors To display the troubles that are present in some system select the appropriate sub menu line If there is an error in some system the relating icon will be activ and You will be aqble to click on it and see the error You can change the presented system in the menu and only those errors that are active in the selected system will be highlighted with red Setup Login as different User A different user may log in Change user password Change current user s username and password User groups See above Windows Contains tools for arranging opened windows About Provides DigiView version number and information about the software creators 15
11. in the Details checkbox and required information will become visible Digi 5 OO 9 Sl FTO Cae Username demo r sock Password Server TECH SUPPORT Database idigiview 4 l tok Server username Server password ij 4 Details 16 32 31 3 Start Total Commander 6 0 ia DIGIVIEWLISER_v3 HU i Login Into the server field the name of the computer which has the SQL server must be given If the server is running on the user s computer on the Windows tray at the bottom right hand corner move the mouse onto the SQL server icon leave it on the name of the server computer will appear This name must be entered into the server field The name of the Database digiview_4 The server username and password are depending on the server s settings Click on the OK button to log in Customizing plan drawing At first the software will try to connect to the systems through the configured COM ports default 1 2 3 4 There is the communication status field in the bottom left hand corner These four tetragon indicate the communication status of the four systems 1 2 3 4 by color The colors are Green Communication ok Red There is no DGP NE panel on the configured COM port Yellow System exists connection failure panel ID PC password registration code not acceptable The next window appearing is the log window containing text format informatio
12. marked and connected to other zones with blue line same as left click on partition button in partition toolbar You can disable this marking with a left click on affected partition button in partition toolbar Manage users window G l The Window that provides comfortable handling of all users in the system can be reached from a menu Tools Manage users or by clicking on the icon in toolbar On the left side there is a list of all users in the system The second row of the table is the label that is used in Digi View for this user All labels can be imported from the configuration window On the right side of the screen all parameters of the selected user from the table on the left are presented Boxes that are grey mean that settings and User name that are valid for this user were not uploaded yet and You should double click the user in the table on left or use the buttons marked on the picture ko DipiView v2 6 Manage users a File Tools Errors Setup Windows About Digikwik SY User 1 1 a Upload label from 1 es partici JE a 9 es particia panel to Digiview User 4 User 5 Sza Upload settings from User schedule panel to Digiview Upload buttons for user settings and names 12 Although their default name in Digiview is a simple count from 1 to 3996 physically each user is present in only one of four systems This means users from 1 999 are users that are set in Control panel 1 Digiplex
13. n time event of events occurred o DigiView v2 6 Map g File Tools Errors Setup Windows About o X s Sh a zi cy 6 AR zap 2 On ia GA Digkw gt 9 50 FE FO 2006 04 05 16 34 09 Software login Demo Start Total Commander 6 0 ia DIGIVIEWLISER_v3 y 15 Login Paint Starting window Click on the Configuration icon on the toolbar Configuration window will appear In the Module tab select the desired COM ports see Appendix and give the Panel ID and PC password Click on the OK button to exit and save After all the floorplan dxf must be imported Click on the DXF icon A notice will appear to close the open floorplan Click on the OK button then close the floorplan window o DigiView v1 7 Map g Fie Tools Errors Setup Windows About Digi gt lt V4 L amp ih Pa to close floorplan 11 37 05 Time remaining 715 seconds w ANGOL DIGIVIEW Total Commander n vtelen Paint Digiview telepit readme Jegyzett Default floorplan closing Click on the OK button to confirm Click again on the DXF icon a textbox will appear Click on the Browse button and select the correct dxf file To activate the changes restart the software If there is no green square in the communicaton status field change the configuration settings The software is running in demo mode now It means the software establishes
14. nking in alarm a red corner is blinking trouble a blue corner is blinking Using the mouse or the Zoom buttons left bottom of screen You can change the change the area of the plan that is presented You can also change the presented area of the plan using a left mouse button anywhere on the plan grab and move the whole plan in any direction You can toggle On Off the Partition toolbar and the log window using the icon buttons to use the whole screen for plan viewing 6 K gt DigiView v2 6 Map EES a X g File Tools Errors Setup Windows About Digiw DQ 2 BH 0 Toggle buttons a v MMMM 15 51 13 Buttons for toggling Log window and Partition buttons In case of alarm a new textbox appears containing all alarm events This box wil dissapear when the alarm was acknowledged by clicking on the button on bottom of the box Alarm events 2006 04 13 16 07 19 Control panel z rea 1 Aight Burglary alarrnone 01 2006 04 13 16 01 13 Lontrol panel 4rea 1 Aight Burglary alarrrmZone D OK and delete events Alarm events window 11 Partition toolbar Each on line panel has a row of buttons so does up to 4 x 8 buttons Each button has label as defined in the configuration window The colour of the button indicates the status of the partition gt Disarmed normal state grey colour gt Armed red gt In alarm black red blinking gt trouble light
15. on to overwrite the labels in Digiview database and close this window You can also edit each label in the Configuration window to change the label of every Partition Zone Door and User in Digiview program Under the Current heading in the Events Commands and Errors tabs You can change labels that will be stored in the event list In the same table there is a Soundfile column that presents a path of the wav file that will be played when the mentioned event command or error happens Digi w amp OO 2 BN EE e Partition a s Panton Patton Panton3 Pansona Pannon Pamong Partson 10 Pa non12 Pa ton13 Pa moni Pammonis Pannonie i x Partitions Zones Events Commands Colours Communication Errore Soundfile of event 4 mieuratw Alarm duration finished Alarm duration finished Alarm was generated by Alarm was generated by 12 Armed system with remo Armed system with remo Auto arm engaged Auto arm engaged gt Auto arm time reached Auto arm time reached i 4 Burglary alarm Burglory alarm Burglary alarm restore Burglary alarm restore Cancel alarm reporting o Cancel alarm reporting o End of alarm duration fin End of alarm duration fin ELA 1251 05 Time remaining 726 seconds Sound import for Events Selecting a file can be done by clicking in the Soundfile column next to the event Command Error we want to set up and after that on the binocular icon on top of
16. or use the two buttons in the bottom left corner After setting the right view click the right mouse button onto the place where the item would be placed A menu appears providing a choice to Add device zone Add door or Add text lt gt DigiView v2 6 Map g Fie Tools Errors Setup Windows About x Digi fk QQ 9 Si CTO Cas Add text Add door Normal size A EBU 16 36 29 Placing a device Click on Add text to put a new label in the floorplan Click on Add device and a new window appears In this window in the roll down list You can choose one from the four systems and after that select the zone You would like to place on drawing Control panel Partition Label Glyph ggi BOO O g Adding a device The software automatically selects the right partition the zone belongs to In the Description field user may type a text such as the name of the zone which will appear in the floor plan Select the desired icon that will present tis zone on the floorplan and confirm all settings by clicking on the OK button If You select the Add door from the menu similar window will appear where You can select the parameters panel door and a description of the door You would like to place on the plan as a new icon This icon will present the door s state with it s colour Repeat these procedures to insert another device Door Label until You have added all zones doors and labels You would like to see in graph
17. roup have the same permissions use the buttons under Users tab When You add new or edit an existing user a new window will appear with more information about the selected user Full name User name and password DER ill Te Permissions File Edit devices EJ Setup e og query EE Tools w Login A Logout L Preferences L Toggle log window on off Log query Toggle partition buttons on off User groups User management Wi Watching devices Configuring Permissions You can configure the selected group s permissions in the right side window under Permissions tab Click in the checkboxes on the right side window to add the described right to every user in the selected group After the modification click Close in the bottom right hand corner to quit settings To activate changes restart the software PREPARING PLANS EDIT WINDOW 74 Switching to Edit mode selecting the pencil icon can be done only if the logged user has the permission to edit see setting up the software users section Click on the Edit pencil icon The Partition toolbar disappears only the header of the window is visible You can toggle on of the log window and partition buttons with the last two icons see page5 The floor plan can be grabbed and moved with the left mouse button To zoom in and out use the mouse roll
18. the table A browse window will open and You can find and open the desired audio wav file The software will play the selected audio when the specific event command or error occurs To activate changes restart the software Setting up the software users Click on the Setup in the toolbar select User groups In this panel user can define user groups with permissions gt DigiView v2 6 Map g Tools Errors 5 Digi SO SP PSEUDO CRS Partitions Part 1 Midle UK6RFUR GEF Part 5 Midle Part 6 Midle Area 1 Right _Area 2Riaht Area 3Rioht area 4 Richt MAE area 6 Riaht Partition 1 left P 5 Part 7 Midle Part 8 Midle _Area 7 Rioht_ Area 8 Right Vie e9 Partition s let Users Permissions a Name 2 i User John Smith User John Doe i System administrators Full name User John Doe user2 Username Password u2 5 alarmbox Paint s configureicon Total Command ta DIGIYIEWUSER HU Managing users Click on the button in the Group heading on the left side to create a group To delete selected group use button To change the name of the group use the third buttton The black triangle and the blue color shown next to the name of the group indicates the currently selected group To add delete or modify users that are in the selected g
19. will be displayed The listed events can be filtered by three limitations 1 Time interval 2 Affected object Panel Partition Zone Door or User 3 Type of desired event Event Command or Error To activate flitering click in the checkboxes of the desired filtering select the limits and use the Start button to list all events from database that fulfill selected criteria You can also use multi layer filtering for example Check when did the User 33 John Smith approached Door 33 during last week time interval 2006 04 10 2006 04 16 Or check the Errors in Partition 28 that belongs to Panel 3 A Partition or zone can be selected ONLY after the corresponding Control panel has been selected o DigiView v2 6 Log query File Tools Errors Setup Windows About BX Digiw gt 9Q CP PG RM CUNO fas Time interval from to Control panel L Door User Events Commands Errors og Start Export to txt file Empty log Close window Time Control panel Partition Partition Zone Zone Message Door _ Door_ Usert User 4 2006 04 13 10 59 31 4 29 5 6s Partici System is ready 2006 04 13 10 59 31 4 30 6 os Partici System is ready 2006 04 13 10 59 31 4 31 76a sodtifoguheja System is ready 2006 04 13 10 59 31 4 32 86AUSODUFOGUHE System is ready 2006 04 13 10 59 31 4 32 86AUS DUF GUHE Partition in trouble 2006 04 13 10 59 39 4 27 3 as Particio System in exit delay 2006 04