PWR-60 charger manual
Contents
1. 2 24 48V selector switch adapts the wind battery charger unit to various battery voltages The wind charge controller has a battery overcharge protection function using the so called dump load technique The excess energy of the generator is transferred to a resistive dump load e g heating element which keeps the generator under loaded condition This prevents the rotor from overspinning and saves it fro any resulting damages 12 24 48 V selector switch The unit can be used for charging 12V 24V and 48V battery banks Please switch the selector to the appropriate position prior to connecting the charge controller to any system component The selector switch is located beneath the cover on the PCB Battery overcharge protection and dump load When the battery has reached a fully charged state the excess current from the generator is transferred to a dump load heat element via solid state MOSFETs The filament of DL 24 dump load is made of NiCr material which prevents the humming noise during operation which is a typical characteristic of ferrite based heating elements LCD indication The actual battery voltage and the actual battery charging current is shown on the two LCD displays Protections A blocking diode protects the batteries from alternating DC currents which has a lifetime decreasing effect on the batteries A capacitor permits the disconnection of the battery terminals in all circumstances Connection and operating elem
2. Specifications Nominal battery charging voltage Minimum battery charging voltage Typical generator voltage Maximum charging current Max generator current Regulator s cut off voltage at 25 C Max open circuit voltage Max short circuit current Max current consumption Operating temperature Enclosure Screw terminals Dimensions Hx WxL Weight Voltage and Current meters Measuring voltage Voltage resolution range Measuring current Current resolution range Suggested dump load Weight Switching frequency Subject to alteration 12 24 48V switch selectable switch located beneath cover 9 18 36V 3 x 120VAC unloaded other rating upon request 60A all voltages higher rating upon request max 50A phase 14 1 28 2 56 4V 60 80V 200A 3mA 20 50 C Metal housing with paint finish 16 mm reachable from outside 125 x 400 x 325 mm 6 kg 10 icon DUY 0 1 V 0 60A 100mA DL 24 24V 60A NiCr 80 in aluminium touch free cage 2 kg Approx 1 kHz June 2004 Panelectron Ltd R zsa u 3 9 52 H 1045 Budapest Hungary Tel Fax 36 1 370 8007 E mail info panelectron hu URL http www panelectron hu OPERATING INSTRUCTIONS Ce PWR60 type wind charge controller 12 24 48 V 60A Dear Customer Thank you for buying our product You have bought one of the most powerful compact and reliable units of its class Please read the operating ins
3. ble end into two parts and connect them to the screw terminals after preparing them appropriately To prevent voltage losses in the cabling please use min 16 mm cable diameter up to 1 2 m Only when an additional short circuit protection device is already installed can the battery be operated without a fuse Otherwise a fuse must be connected to the battery pole in order to prevent possible short circuit of the battery cables Both components must be installed close together in the same room 3 Connect the dump load to the corresponding terminals Extra load When charging a 12V battery bank use two DL 24 dump load connected in parallel when charging a 24V battery bank use one DL 24 dump load and when charging a 48V battery bank use two DL 24 dump load connected in series see picture below The dump load can be any 12 24 48Vdc max 60A rated equipment such as lights water pump motors etc SUITABLE DUMPLOAD THIS WOULD CAUSE GENERATOR OVER SPINNING AND WOULD DESTROY BOTH WIND GENERATOR AND THE CHARGE CONTROLLER ELECTRONICS 4 Connect the AC generator to the corresponding terminals L1 L2 L3 Please use a 3 phase AC generator with typical 1400W output shown on the right unless otherwise agreed with manufacturer Diagram kW per m s 5 You can start the unit by turning the main switch 2 into position 1 Before turning on the unit please make sure that all conditions are safe and appropriate for starti
4. ents 1 LCD display for battery voltage and current 1 oo 2 Main switch 3 Generator input 3 phase 4 Battery terminals 2 5 Extra load output 6 Heat sinks L1 L2 L3 Extraload voy Installation Warning Make sure of the right polarity The wind charge controller unit should be placed in close proximity to the battery and be sufficiently protected against the weather Make sure to place the battery in a well ventilated place To guarantee that the unit functions properly it must be connected to the wind or hydro generator the lead battery bank and the extra load dump load at the same time Each part of the system wind or hydro generator lead battery and extra load should have the appropriate nominal ratings Please carefully check each component before connection when in doubt contact a specialist Take careful attention of the following installation instructions l Make sure that the main switch 2 is in 0 position This switch operates as a break switch which short circuits the 3 phases of the AC generator 2 Connect the battery to the corresponding terminals on the wind charge controller In order to prevent the screw terminals to overheat at high currents the power is shared between four terminals two positive two negative Divide each battery ca
5. ng the operation Maintenance As the cooling of the wind charge controller is achieved by convection cooling no fans no moving parts inside the charger basically does not require maintenance The two heat sinks 6 should occasionally be made free of dust to allow free air movement
6. tructions carefully before use WARNING Safety Instructions Do not use the unit In places which are dusty damp in a high humidity area over 80 rel humidity at temperatures above 50 C in areas containing inflammable materials liquids solvents gas Do not immerse in water Use only in closed dry and hot areas Should the unit fail to operate or show signs of not operating properly disconnect it immediately and make sure that the unit is not put into further operation Do not use the unit when visible signs of damage due to transport or inadequate storage are noticeable Use only wind or hydro generators with corresponding characteristics as power source To prevent the risk of explosion install the battery in a well ventilated place To prevent a short circuit between wind charger unit and battery always install a fuse on the positive battery pole Follow installation instructions strictly when connecting the unit The unit should be disconnected in reverse order see installation procedures Description of operation Wind Charge Controller Unit 12 24 48V 60A with 12 24 48V selector switch LCD display for system voltage and current Dump load protection against battery overcharging Convection cooled The PWR60 wind charge controller is suitable of charging lead battery banks with max 60A nominal charging current which is supplied by an AC 3 phase permanent magnet generator The 1