Home
CR-R885-SB : Installation and Operating Instructions
Contents
1. User Operation User Access x Panic Alarm User Code Table 24 Warranty 26 PosiPIN 1 INSTALLATION To select an installation site Avoid wiring the PosiPIN cables in the same conduit as AC power cables lock power or signal wiring Reader wiring must remain a minimum of 30cm 12in away from other wiring such as wiring for AC power computer data telephones electric locks etc Avoid sites within 1 1m 3 5ft of computer monitors or CRTs Avoid sites near sources of broad spectrum EMI noise such as motors pumps generators DC to AC converters AC switching relays power supplies and light dimmers Avoid sites near potential sources of RF signals such as cellular phones two way radios etc MOUNTING AND WIRING Use the mounting plate as a guide to drill two holes to secure the mounting plate and a hole for the cable 0 95cm to 2 54cm 0 375in to lin wide Place a grommet around the edge of the hole for the cable Prepare PosiPIN s cable by cutting the cable jacket back 3 175cm 1 25in and stripping the wires back 0 635cm 0 25in Splice PosiPIN s wires with a recommended cable wire See page 7 and connect as shown in Figure 1 on page 5 2 Installation and Operating Instructions MOUNTING ON METAL SURFACES Although the read range may dec
2. Enter Description 0 Display on Card Read disabled 1 Red Status LED flashes 2 Green Status LED flashes 3 Red and green Status LEDs flash 4 Face Light flashes 5 Face Light and red Status LED flash 6 Face Light and green Status LED flash 7 Face Light and both Status LEDs flash 12 Installation and Operating Instructions Select 0 in Section 103 Face Light Operation on page 14 to enable options 0 to 3 in section 004 or select 1 in Section 103 Face Light Operation on page 14 to enable options 4 to 7 in section 004 SECTION 005 KEYPAD LOCKOUT When Keypad Lockout is enabled and the Installer Code is entered incorrectly 3 consecutive times the keypad ignores all entries for 60 seconds Option 0 by default Enter Description 0 Keypad Lockout disabled 1 Keypad Lockout enabled SECTION 101 BUZZER SETTING The number of beep tones emitted as a response to a card being presented to the reader can be adjusted from 0 disabled to 7 7 rapid beep tones Option 3 by default SECTION 102 FACE LIGHT INTENSITY The Face Light s illumination can be adjusted according to the installation s requirements from 0 extinguished to 8 brightest Option 4 by default PosiPIN 13 SECTION 103 FACE LIGHT OPERATION The Face Light can be set to remain illuminated continually or can follow the state o
3. RESETTING TO DEFAULT To reset all sections to factory defaults disconnect reader s power supply Press and hold the 1 and 2 keys simultaneously while re connecting its power supply The reader will emit a confirmation beep Repeat this procedure a second time holding the 3 and 4 keys Sections are reset when the reader emits the second confirmation beep PosiPIN 7 CARD PRESENTATION TEST Place the card paralleltothe PosiPIN reader as shown in the figure and move it toward the reader until the reader provides audio or visual feedback 8 Installation and Operating Instructions SYSTEM PROGRAMMI NG The Installer Code default 000000 can program a new Installer Code PIN in section 200 and program all the system sections from 001 to 005 and 101 to 104 To Enter System Programming Mode 1 Press and hold the CLEAR key for 4 seconds The reader emits a confirmation beep the green LED illuminates and the red LED extinguishes Enter the INSTALLER CODE and press the ENTER key Reader emits a confirmation beep and the green LED flashes Enter the 3 digit SECTION and press the ENTER key Reader emits a confirmation beep and green LED becomes constant Enter the required DATA and press the ENTER key The reader emits a confirmation beep and the green LED flashes To program another section repeat steps 3 and 4 To exit press and hold the CLEAR key for 4 sec
4. CLEAR and ENTER keys for 2 seconds The Panic Alarm will activate the panic output see Figure 1 on page 5 Access will not The second user s card and or User Code must be different from the first 22 Installation and Operating Instructions be granted to users until the Panic alarm is disarmed Disarming a Panic Alarm depends on the Card Code Option see page 10 and Access Granted Option see page 11 To disarm a Panic Alarm Single Dual Dual Access Access Access Granted with Granted Granted Dual Panic Disarm Reader Present 1 valid 2 users each user Only card to the reader presents a valid card to the reader Keypad Enter 1 valid User 2 users each user Only Code and enters a valid User press the ENTER Code and presses key the ENTER key Reader Present 1 valid 2 users the first and card to the reader user presents a Keypad then enter 1 valid valid card to the User Code and press the ENTER key reader then must enter a valid User Code and press the ENTER key The second user has 30 seconds to present a valid card to the reader and then enter a valid User Code The second user s card and or User Code must be different from the first PosiPIN 23 USER CODE TABLE Use this table to keep a record of the User Codes If you require extra pages photocopy this table The PIN column is provided for your convenience however we recommend not using i
5. including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold Notwithstanding the preceding paragraph the Seller s maximum liability will be strictly limited to the purchase price of the defective product Your use of this product signifies your acceptance of this warranty BEWARE Dealers installers and or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller 2001 2003 Postion Technology Inc PosiPIN is a trademark or registered trademark of Position Technology Inc or its affiliates in Canada the United States and or other countries All rights reserved Specifications may change without prior notice APPROVAL c O Compliant to all EU and EFTA countries except Greece according to RTT amp E directives 26 Installation and Operating Instructions Notes PosiPIN 27 5 Position Technology s an affhated company of KA KAS DO S secueity systrina ww paradox ca 780 Industriel Bivd Saint Eustache Quebec J7R 5V3 CANADA Tel 450 491 7444 www postech ca Fax 450 491 2509 Printed in Canada 12 2003 CRR885SB EI02
6. programming The reader emits a confirmation beep once the modification is complete USER OPERATION USER ACCESS Access is granted according to the Card Code Option see page 10 and the Access Granted Option set see page 11 Single Access Dual Access Granted Granted Reader 1 user user 2 users each user Only presents a valid presents a valid card card to the to the reader reader Keypad 1 user user 2 users each user in Only enters a valid turn enters a valid User Code on User Code on the the keypad and keypad and presses presses the the ENTER key ENTER key PosiPIN 21 Single Access Granted Dual Access Granted Reader and Keypad 1 user user presents a valid card to the reader The reader emits a confirmation beep and the green Status LED flashes User must enter a valid User Code on the keypad and press the ENTER key within 10 seconds 2 users the first user presents a valid card to the reader The reader emits a confirmation beep and the green Status LED flashes The first user must enter a valid User Code on the keypad and press the ENTER key within 10 seconds The reader will emit a Confirmation Beep and the red Status LED flashes slowly The second user has 30 seconds to present a valid card to the reader and then enter a valid User Code PANIC ALARM A panic alarm can be generated by pressing and holding the
7. CTION 003 ACCESS GRANTED OPTIONS The Access Granted Options depend on the Card Code Options set in section 001 Option 0 by default Enter Description 0 Single Access Granted 1 Dual Access Granted 2 Dual Access Granted with Dual Panic Disarm Single Access Granted When 0 is programmed one user can obtain Access Granted by using a valid card code or both depending on the Card Code Option set Dual Access Granted When 1 is programmed two users are required to obtain Access Granted Each user must use a valid card code or both depending on the Card Code Option set Only one user is required to disarm a Panic Alarm PosiPIN 11 Example When the reader and the keypad are enabled User 1 must present a valid card and enter a valid code and then User 2 must present a valid card and enter a valid code for Access Granted Dual Access Granted with Dual Panic Disarm When 2 is programmed two users are required to obtain Access Granted same as Dual Access Granted and two users are required to disarm a Panic Alarm For example a Panic Alarm is triggered User 1 must present a valid card and enter a valid code and then User 2 must present a valid card and enter a valid code to disarm the alarm SECTION 004 DISPLAY ON CARD READ The visual feedback when a card is presented to the reader can be adjusted according to the installation s requirements Option 3 by default
8. ILD PIN and Proximity Reader Stand alone CR R885 SB S DI o B008088 Installation and Operating nstructions v1 1 Position Technology TABLE OF CONTENTS Installation Mounting and Wiring r Mounting on Metal Surfaces e Technical Specifications Feedback Resetting to Default RE 3 Card Presentation Test nennen System Programming 9 Section 001 Card Code Options 10 Section 002 Door Lock Control 10 Section 003 Access Granted Options 11 Single Access Granted 11 Dual Access Granted rr 11 Dual Access Granted with Dual Panic Disarm 12 Section 004 Display on Card Read aace 12 Section 005 Keypad Lockout te Section 101 Buzzer Setting Section 102 Face Light Intensity Section 103 Face Light Operation Section 104 Face Light Colour Section 200 Changing the Installer Code 14 Resetting the Installer and Master Codes to Default 15 Master Programming 16 Sections 201 and 202 Changing the Master Codes aan gen Section 203 User Code Programming Deleting a User Code S Section 204 User Code Reset
9. ING Master Programming Mode is used to program Master and User Codes SECTIONS 201 AND 202 CHANGING THE MASTER CODES Master Code 1 default 111111 is used to program both Master Codes the User Codes and the Section 002 Door Lock Control see page 10 Master Code 2 default 222222 can program the User Codes and change its own PIN Master Code 2 cannot program Master Code 1 or the Door Lock Control In the desired section enter the 6 digit personal identification number PIN where each digit can be any value from O to 9 To Change the Master Codes 1 Press and hold the CLEAR key for 4 seconds The reader emits a confirmation beep the green LED illuminates and the red LED extinguishes 2 Enter MASTER CODE 1 or MASTER CODE 2 and press the ENTER key Reader emits a confirmation beep and the red and the green LEDs flash simultaneously 3 Enter 201 to change Master Code 1 or 202 to change Master Code 2 and press the ENTER key Reader emits a confirmation beep and the green LED becomes constant 4 Enter the new PIN and press the ENTER key 16 Installation and Operating Instructions The reader emits a confirmation beep and both LEDs flash 5 To exit press and hold the CLEAR key for 4 seconds The reader emits a rejection beep and the green LED extinguishes SECTION 203 USER CODE PROGRAMMING Master Code 1 and 2 can activate cards and program the personal identification numbers PIN fo
10. f the Status LEDs Option 1 by default Enter Description 0 Face Light constant 1 Face Light follows Status LEDs If 0 in section 103 is selected this will override options 4 to 7 in Section 004 Display on Card Read on page 12 In addition if 1 in section 103 is selected this will override 0 to 3 in Section 004 Display on Card Read on page 12 SECTION 104 FACE LIGHT COLOUR The Face Light s colour can be modified as desired Option 0 by default This feature only applies when Face Light Operation programmed in Section 103 is set for Option 0 Face Light constant Enter Description O Blue Face Light 1 Green Face Light SECTION 200 CHANGING THE INSTALLER CODE The Installer Code 000000 by default is used to program all the system s sections but cannot program the Master and User Codes see 14 Installation and Operating Instructions page 16 In section 200 enter six digits where each digit can be any value from 0 to 9 RESETTING THE INSTALLER AND MASTER CODES TO DEFAULT To reset the Installer Code Master Code 1 and Master Code 2 to factory defaults disconnect the reader s power supply Press and hold the 3 and 4 keys simultaneously while re connecting its power supply Installer Code Master Code 1 and Master Code 2 are reset when the reader emits a confirmation beep PosiPIN 15 MASTER PROGRAMM
11. h alternately Enter the number of the desired User Code Press the ENTER key The reader emits a confirmation beep and the green LED illuminates If the number is available the red LED illuminates If the red PosiPIN 19 LED remains extinguished a User Code is already programmed using that number Press the CLEAR key The red LED flashes Press the ENTER key to confirm the removal and advance to the next section Press and hold the CLEAR key to exit the section Press and hold the CLEAR key for 4 seconds to exit SECTION 204 USER CODE RESET User Code Reset is used to delete all the User Codes from User Code 000 to 999 To Reset all User Codes l Press and hold the CLEAR key for 4 seconds The reader emits a confirmation beep the green LED illuminates and the red LED extinguishes Enter MASTER CODE 1 or MASTER CODE 2 and press the ENTER key Reader emits a confirmation beep and the red and the green LEDs flash simultaneously Enter 204 and press the ENTER key Reader emits a confirmation beep and the red and the green LEDs flash alternately Press the 1 key and then press the ENTER key to confirm the reset This may take a few seconds then the reader emits a confirmation beep when the User Codes are deleted 20 Installation and Operating Instructions When the User Codes are reset it may require several seconds for the system to update the
12. onds The reader emits a rejection beep and the green LED extinguishes PosiPIN 9 SECTION 001 CARD CODE OPTIONS PosiPIN can function as a reader only as a keypad only or as acombined reader and keypad Option 3 by default Enter Description 0 Keypad and reader disabled For programming only 1 Reader only Present valid card to the reader for Access Granted 2 Keypad only Enter valid code on the keypad for Access Granted 3 Keypad and reader enabled A user must present BOTH a valid card AND enter a valid code to receive an Access Granted When a Card Code option is set it may require several seconds for the system to update the programming The reader emits a confirmation beep once the modification is complete SECTION 002 DOOR LOCK CONTROL The Door Lock Control determines the length of time the locking device remains unlatched after an Access Granted When 0 is programmed the lock is unlatched after an Access Granted and remains unlatched until it receives a second Access Granted functions like a key When 1 to 5 is programmed the lock remains unlatched for the defined time period Option 2 by default 10 Installation and Operating Instructions Enter Description 0 Card Code Controlled Free Access Latched 1 1 second 2 5 seconds 3 10 seconds 4 20 seconds 5 60 seconds SE
13. r the User Codes PosiPIN includes 1000 User Codes User Code 000 to 999 can be 1 to 8 digits in length where each digit can be any value from 0 to 9 You can use the table on page 24 to record the User Codes To Program User Codes 1 Press and hold the CLEAR key for 4 seconds The reader emits a confirmation beep the green LED illuminates and the red LED extinguishes 2 Enter MASTER CODE 1 or MASTER CODE 2 and press the ENTER key Reader emits a confirmation beep and the red and the green LEDs flash simultaneously 3 Enter 203 and press the ENTER key Reader emits a confirmation beep and the red and the green LEDs flash alternately 4 Enter the User Code number from 000 to 999 Press the ENTER key The reader emits a confirmation beep and the green LED illuminates If the red LED PosiPIN 17 illuminates the section is empty If the red LED stays extinguished a User Code is already programmed in the section 5 Program the card access code or both combined according to the option selected in section 001 see page 9 Then enable one of the following options e Reader only present the card to the reader without pressing the ENTER key The reader will automatically advance to the next User Code e Keypad only PIN is less than 8 digits enter PIN and press the ENTER key to advance to the next User Code e Keypad only PIN is more than 8 digits enter PIN the reader will automatically advance
14. rease PosiPIN can be mounted on metal However do not box in or surround the card reader with any kind of metal If the reader must be installed in a metal enclosure ensure that the face of the card reader is not covered and that at least 1 6 4cm remain between the card reader and the metal on all sides of the card reader TECHNICAL SPECI FI CATIONS Input Voltage Input Current Consumption Frequency Operating Temp Cable Distance Suggested Cables Indicators Typical 13 8Vdc min 11 0Vdc max 14 5Vdc Typical 65mA E 12 5Vdc with card 105mA Typical 812mW E 12 5Vdc with card 1 31mW Exciter Field 125kHz Pulse Modulated receive low 12 5kHz Receive high 15 625KHz 25 C 13 F to 65 C 149 F 152 4m 500ft 22AWG 0 8mm Multi conductor Alpha 5196 5198 18AWG 1 2mm Multi conductor Alpha 5386 5388 Belden 9553 18AWG 6 conductor stranded w overall shield Beeper red LED and green LED PosiPIN 3 For CR R885 S red and green Face Light For CR R885 SB blue and green Face Light Weight 280g 9 8 oz Material Black UV resistant ABS plastic Dimensions 99 5mm 5 75 x 118 5mm 2 x 19 5mm 1 Wire Function Brown Not used Black Ground Green Panic Out White COM Yellow Normally Closed N C Orange Normally Open N O Red 12Vdc 4 Installation and Operating Instructions Figure 1 Connection drawing 12V Locks sq31 Snes 46N 9984 CON
15. t for security reasons User Name Card PIN Code Number optional 24 Installation and Operating Instructions User Code Name Card Number PIN optional PosiPIN 25 WARRANTY Paradox Security Systems Ltd Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product s inability to operate Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications Returns must include proof of purchase and be within the warranty period In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental
16. to the next User Code after you have entered the 8th digit e Keypad and reader present the card to the reader followed by the PIN Press the ENTER key to advance to the next User Code 6 Return to step 5 to program another card otherwise to exit e Press CLEAR key The red and green LEDs will flash alternately e Press the CLEAR key a second time Both LEDs will flash simultaneously Press and hold the CLEAR key a third time to exit this section 18 Installation and Operating Instructions When you press the CLEAR key in step 5 If the User Code is not programmed PosiPIN will revert to step 4 If a card or PIN was entered press the Enter key to confirm the removal and advance to the next user code or press the CLEAR key to enter a new user code If you press and hold the CLEAR key you will exit this section entirely DELETING A USER CODE User Codes can be deleted individually When the User Code is deleted a new card and or PIN can be programmed in the section To Delete User Codes 1 Press and hold the CLEAR key for 4 seconds The reader emits a confirmation beep the green LED illuminates and the red LED extinguishes Enter MASTER CODE 1 or MASTER CODE 2 and press the ENTER key Reader emits a confirmation beep and the red and the green LEDs flash simultaneously Enter 203 and press the ENTER key Reader emits a confirmation beep and the red and the green LEDs flas
17. usdo Ajlew uon Bue4o C N Pasoj Alewuaon mollaA WOD SYUM MO lueg u 1i9 punoig M9e 9 pasn Joy UMO1g PISIUS pi us uorpung SIM ind3ino 3lued 104 ejay g e ON OH WOD jddns Jamod AZT Ajuo S420 AZT YUM Sen 40 papuajul s UoIP3UU09 paujino PosiPIN 5 Figure 2 Connection Drawing 24V Locks 503 Stee nd no 3lued 104 Aejay YN OH WOD A ddns J93MO0d Apz 14611 3924 PAZT Den O N u do ewJoy bueJo O N pasoj Allew uon moljaA WOD YUM MO Ued U33419 puno49 mpeg pasn JON umoug AJUO 5190 ABZ UA Sen Dous pi us 104 papuayu si uo 2 uuo2 paulino uopung SIM A ddns Jamod AZT 6 Installation and Operating Instructions FEEDBACK Depending on the programming mode chosen the feedback will differ In the section System Programming on page 9 and Master Programming on page 16 the combinations of visual feedback and beep tones are specified step by step Visual Feedback When information is entered on the reader s keypad the red and or green LEDs will flash remain constant or extinguish depending on the step reached in programming Confirmation Beep When an operation is successfully entered the reader emits a rapid series of beep tones beep beep beep beep beep Rejection Beep When the system reverts to a previous status or an operation is incorrectly entered the reader emits one long beep tone beeeeeeeeeep