Home

Added and Changed Features for Installation Manual and

image

Contents

1. PSQX1385ZA KW1297KMO
2. Are the accessed digits abc or de found in a TIE Line Routing Table Checks in program 340 Yes Modifies the dialed number if a removed or added number is assigned Checks in program 341 NG Reorder tone Your extension no TIE or CO call no Calls an extension Routes to the TIE or CO line 17 E 3 Features Receiving a Call through a TIE Line A call is received through a TIE line as follows XXXX abc xxxx dexx Y Is the system allowed to receive TIE dial numbers Checks in program 445 No DIL 1 1 or DIL IN l Yes Modifies the dialed number if a removed or added number is assigned Checks in programs 43 1 436 XXXX Extension no Y dexx abcxxxx Found in a TIE Line Routing Table Checks in program 340 Checks the PBX code abc Checks in program 128 Does the corresponding extension exist No y Modifies the dialed number if a removed or added number is l Yes assigned Checks in program 341 y Disable XXXX Line access Ext no code Checks the code in Calls an program 100 extension Yes Is the TIE to CO Transfer Checks in program 438 or TIE to TIE Transfer Checks in pro
3. 2 Press NEXT Display Location NO gt 5 3 Enter a location number To enter location number 01 you can also press NEXT Display example 01 S 4 Enter a TIE line access code To delete the current entry press CLEAR To change the current entry press CLEAR and enter the new number 5 Press MP to program the CO line group hunt sequence number 6 Entera CO line group hunt sequence number To delete the current entry press CLEAR To change the current entry press CLEAR and enter the new number de Press STORE 8 To program another location press NEXT or PREV or SELECT and the desired location number 9 Repeat steps 4 through 8 10 Press END e Each TIE line access code has a maximum of three digits consisting of 0 through 9 and The character can be used as a wild card character e Program 341 TIE Removed Digit Added Dial is used to modify the TIE line access code 4 341 System Programming TIE Modify Removed Digit Added Dial Description Assigns the removed digits and added numbers of a received TIE call Digits are removed and added from the beginning of the dialed digits Selection e Location number 01 through 32 e Number of digits to be deleted O to 4 O no deletion e Number to be added 4 digits max Default All locations Deleted digit 0 Added Dial Blank Programming 1 Enter 341 Display TIE Remove Add 2 Press NEXT Display Locatio
4. gt n a gt n a gt n a gt gt n a gt n a gt gt TR gt n a gt n a gt Sends OGM 4 and then disconnects the line Sends OGM 4 and then transfers to an overflow extension Sends OGM 4 Music on Hold for 16 seconds and then disconnects the line Sends OGM 1 OGM 2 OGM 3 and then disconnects the line Sends OGM 4 Music on Hold for 16 seconds OGM 1 and then disconnects the line Sends OGM 4 Music on Hold for 16 64 seconds and then OGM 4 again Sends OGM 4 repeatedly Directly transfers to an overflow extension Waits for an idle extension The caller hears a ringback tone IRNA works Waits for an idle extension The caller hears a ringback tone IRNA works Waits for an idle extension The caller hears a ringback tone IRNA does not work Waits for an idle extension The caller hears a ringback tone IRNA does not work Waits for an idle extension for 16 seconds and then transfers to an overflow extension n a not available for assignment 26 3 Features U Note e The UCD Time Table is not available for incoming extensions or transferred calls If the overflow extension or Time Table number is not assigned the system does not answer the call and waits for any extension to be idle In this case IRNA will be employed If the system sends the OGM after queuing the OGM answering time is subject to the time
5. S4 TR RT 1T 2T 3T 4T Blank 127 lt Note gt Available for KX TD1232 only 6L 106 109 128 129 220 106 Station Hunting Type 128 PBX Code 129 E amp M Signal Assignment Selection EE Parameter Default Selection all 1121314151617 18 Default 1 3 digits 0 9 Disable Vv Nob sigicd Continuous Vv Terminate ati Seip ae ene fi Pulsed Ans Circular Pulsed No Ans Voice Mail We Pa ae OW aa Automated Attendant E CR ES E EH UCD ERES 109 Extension Card Unit Type 220 TIE First Inter Digit Time TD816 Area No 1 2 Selection C aire EMEA CISIIS EMI EIA Default 10s Default W Y Parameter Parameter i MA TE Master System Selection 3 30 Area No 1 2 3 Selection C S1 S2 EM El E2 A1 A2 C S1 2 EM E1 E2 A1 A2 C S1 2 EM El E2 A1 A2 Det vi fi tit AA AE E E AM E Slave System Area No 1 2 3 Selection C ai S2 EM El E2 AL A2 CI SI S2 EM EI E2 A1 A2 C S1 2 EM E1 E2 A1 A2 PEE A Ee ae Hae Elo SS poi ii lt Note gt TD816 C 4CO S1 2S0 2 6S0 EM 4E amp M E SEXT A 16SLT TD1232 C 4C0 S1 2S0 S2 6S0 EM 4E amp M El SEXT 1 E2 8EXT 2 A1 16SLT 1 A2 16SLT 2 117 119 117 Voice Mail Number Assignment Jack No 02 64 TD1232 Parameter Jack
6. When extension C is busy or UCD log out has been set in extension C the call arrives at extension A 25 U 4 When all extensions in a UCD group are busy or not available the incoming outside call will be handled by the UCD Time Table An example is shown below UCD Time Table Assignment 3 Features Sequence Assignment UCD FN OFN TT TT SEQUENCE 1 191 101 1 1 S1 gt 4T gt 4T gt TR gt 2 192 291 2 S1 gt 2T gt gt gt 3 193 3 S4 gt RT gt gt gt 4 194 4 TR gt gt gt gt 5 291 6 292 S1 Send OGM 1 7 293 S2 Send OGM 2 294 S3 Send OGM 3 S4 Send OGM 4 UCD UCD Group Number 1 8 TR Transfer to overflow extension FN Floating Number of the UCD Group RT Return to top OFN Overflow Extension Number Blank Disconnect the line TT Time Table Number 1 4 IT Timer 16 seconds 2T Timer 32 seconds 3T Timer 48 seconds 4T Timer 64 seconds Sequence Activation Examples O S4 O S4 O S4 REN O S4 O S4 O S4 O TR O RT O O 1T OUT OIT gt gt gt gt gt TR gt n a gt gt n a gt n a gt gt gt IT gt S2 gt S3 gt IT gt S1 gt IT gt RT gt n a gt RT gt n a gt n a gt n a gt n a gt n a gt n a gt gt n a gt n a gt n a gt
7. Grp 4 UCD Grp 5 UCD Grp 6 UCD Grp 7 UCD Grp 8 e DDI Number 1 through 6 digits 811 Installation Manual This program has been changed to the new one See DISA User Codes Section 4 page 71 813 Installation Manual This program has been changed to the new one See Floating Number Section 4 pages 72 and 73 Assignment 990 Installation Manual The default of Field 24 has been changed from 0 to System Additional Section 4 1 allow Information Fields 39 40 and 41 are added to Area 6 See pages 74 and 75 for details 60 3 Features S Station Message Detail Recording SMDR Description Station Message Detail Recording SMDR automatically records detailed call information for outside calls A printer connected to the EIA RS 232C port can be used to print incoming and outgoing outside calls as well as print a hard copy of the System Programming To print the call records use the program 800 SMDR Incoming Outgoing Call Log Printout which allows you to print out the following records e Records of all outgoing outside calls or outgoing toll calls e Record of incoming outside calls There are three types of the call record which are the regular call record the charge call record and the meter call record An example of a printed regular call record When selected for the regular display by Program 815 SMDR Output Mode 06 24 93 06 24 93 06 24
8. KX TD816 05 through 08 x x all CO lines KX TD1232 09 through 12 Master 21 through 24 Slave X all CO lines 2 wire 4 wire All CO lines 2 wire 1 Enter 442 Display Voice Path Type 2 Press NEXT Display CO Line NO gt 3 Enter a CO line number To enter CO line number 09 you can also press NEXT Display example CO09 2 Wire 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 Press END To assign all CO lines to one selection press the key in step 3 54 System Programming 443 Description Selection Default Programming Conditions Voice Level Transmit Assigns the transmitted voice level on a CO line port basis This program is valid only when the voice path type is set to 4 wire e CO line number KX TD816 05 through 08 X all CO lines KX TD1232 09 through 12 Master 21 through 24 Slave X all CO lines e 6 db 3 db 0 db 3 db All CO lines 3db 1 Enter 443 Display Voice Level TX 2 Press NEXT Display CO Line NO gt 3 Enter a CO line number To enter CO line number 09 you can also press NEXT Display example CO09 3db 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 Press END To assign all CO lines to one selection press the key in step 3 55 444 Description Selection Default Programming
9. Press STORE 5 Press END If the overflow extension or Time Table number is not assigned the system does not answer the call and waits for any extension to be idle In this case IRNA will be employed Section 3 Features in this manual Uniform Call Distribution UCD 34 4 3 System Programming 127 Description Selection Default Programming Conditions Feature Reference UCD Time Table Assigns the queuing sequence in the UCD time table The queuing sequences are as follows S1 Sends DISA outgoing message 1 Si Sends DISA outgoing message 2 S3 Sends DISA outgoing message 3 S4 Sends DISA outgoing message 4 TR _ Transfers to the overflow extension RT Returns to the top of the sequence Blank Disconnects IT Timer 16 seconds 2T Timer 32 seconds 3T Timer 48 seconds 4T _ Timer 64 seconds e Time table number 1 through 4 e S1 5S2 83 S4 TR RT 1T 2T 3T 4T Blank All time tables Not stored 1 Enter 127 Display UCD Time Table 2 Press NEXT Display Table NO 5 3 Enter a time table number To enter time table number 1 you can also press NEXT Display example 1 gt gt gt gt 4 Keep pressing SELECT until the desired selection is displayed Display example 1 S4 gt gt gt gt Press gt 5 6 Repeat steps 4 and 5 4 Press STORE 5 Press END e Sx can be assigned in a space other than in the first on
10. 2 through 4 digits Extension number 84 Two Way Transfer 2 through 4 digits Extension number 85 Live Call Screening None 86 Live Call Screening Cancel None 87 Alert None 88 Phantom 2 through 4 digits Phantom extension number Loop CO 1 through 8 CO line group number Group CO 1 through 8 ring tone type number CO ringer frequency For more information about this programming refer to the program 005 Flexible CO Button Assignment in the main Installation Manual f Available when the Digital Super Hybrid System is connected to a Digital 65 Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 100 4 2 Manager Programming Flexible Numbering The following new features have been added Selection Selection number 67 through 85 Feature number 1 to 3 digits for selection number 67 consisting of O through 9 1 or 2 digits for selection numbers 68 through 83 consisting of 0 through 9 1 to 3 digits for selection number 84 and 85 consisting of 0 through 9 Default Number Feature Default 67 TIE line access code None 68 Other PBX Extension 01 None 69 Other PBX Extension 02 None 70 Other PBX Extension 03 None 71 Other PBX Extension 04 None 72 Other PBX Extension 05 None 73 Other PBX Extension 0
11. CO line group TRG number 1 through 8 x x all CO line groups Enable Disable All CO line groups Disable 1 Enter 438 Display TIE CO Transfer 2 Press NEXT Display TRK GRP NO gt 3 Entera CO line group number To enter CO line group number 1 you can also press NEXT Display example TRG1 Disable 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 To program another CO line group press NEXT or PREV or SELECT and the desired CO line group number 7 Repeat steps 4 through 6 8 Press END To assign all CO line groups to the same selection press the key in step 3 In this case the display shows the contents programmed for CO line group number 1 50 System Programming 439 Description Selection Default Programming Conditions TIE to TIE Transfer Enables or disables transferring TIE calls to a TIE line on a CO line group basis This restriction applies to the following 1 A TIE call through another PBX 2 Call Forwarding to a TIE line 3 Call Transfer to a TIE line e CO line group TRG number 1 through 8 x x all CO line groups Enable Disable All CO line groups Enable 1 Enter 439 Display TIE TIE Transfer 2 Press NEXT Display TRK GRP NO gt 3 Entera CO line group number To enter CO line group number 1 you can also press NEXT Display example TRG1 Enable 4 Keep pressing SELECT
12. No 02 16 TD816 Default Ttem Not Stored Master Not Stored TD1232 01 16 lt Note gt VM No TD816 01 08 Slave TD1232 only a gel E E oe gel Lem oo E E EA IO AAA cole SA EES DEE io Ss e ll Y L a E aq A RN O A A E E eo E O A PI E BKS a e a ZS 29 2 5 of wu sa Sjaj S o m soj sb E E EE E E E E O ec ree EEE E eee A a KREMER SS x 3 O GEMA E E EE de E E da E E dn 2 o a 9 g E a A pe 2 amp E S os Bd T se 5 O ss 2 ge do o GI E gj SE SIS Oo gt S Zj z g mnuolirleolalco rlolrlalo n ovlalo EE E E E EE au E GI A KI s gt E ls E a 28 Aan I El TRS INIHI INI EaI INIHI INI aI NI OIL NI COIN iy E a a at ESSE aE E e Ehre EEN E EE h aE i Q bel ka e sc Z SZ jalol lnle l celalola jalol nlo s as S S o o S S o S S alatajalala Is gt e lt 80 18 130 130 Phantom Extension Number Assignment Parameter 2 4 digits consisting of 0 9 Default all Not Stored Item Location Parameter Item Location Parameter Item Location Parameter Item Location Parameter 001 033 065 097 002 034 066 098 003 035 067 099 004 036 068 100 005 037 069 101 006 038 070 102 007
13. Programming 44 Description Selection Default Programming Conditions Line Hunting Sequence Assigns the hunting sequence of idle lines seizing from the smallest to the largest line number or vice versa in a CO line group on a CO line group basis e CO line group TRG number 1 through 8 x x all CO line groups e Small gt Large Large gt Small All CO line groups Small gt Large 1 Enter 441 Display Line Hunting 2 Press NEXT Display TRK GRP NO gt 3 Enter a CO line group number To enter CO line group number 1 you can also press NEXT Display example TRG1 Large gt Small 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 To program another CO line group press NEXT or PREV or SELECT and the desired CO line group number 7 Repeat steps 4 through 6 8 Press END e The default setting Small Large often may cause a busy situation between two PBXs as the same line may be seized by both sides simultaneously In this case we recommend changing the setting of either PBX to Large Small e To assign all CO line groups to the same selection press the key in step 3 In this case the display shows the contents programmed for CO line group number 1 53 442 Description Selection Default Programming Condition System Programming Voice Path Type Assigns the voice path type on a CO line basis e CO line number
14. Transfer Item CO Line Parameter TIE Table No Selection Selection Selection Group No 1 4 Enable Disable Enable Disable Enable Disable Default all Not Stored Y Y Vv all CO line groups 1 2 3 4 5 6 7 8 440 TIE Security 441 Line Hunting 432 TIE Incoming 433 TIE Outgoing Type Sequence Assignment Assignment Item CO Line Selection Selection Item TIE Selection Selection Group No Non Trunk Small Large Large gt Small Table No Immediate Wink Immediate Wink Default all Y Default all v Y all CO line groups all tables 1 1 2 2 3 3 4 4 5 6 7 8 98 434 436 442 445 24 434 TIE Subscriber 435 436 TIE Wink Time Out Number Removed Digit TIE Added Number Assignment Item Parameter Parameter Selection TIE Table No No of digits to be No to be added 1 127 X 64 msec deleted 0 6 4 digits max consisting of O 9 Default all 0 Not Stored 16 all tables 1 2 3 4 442 Voice 443 444 445 TIE Path Type Voice Level Transmit Voice Level Receive Receive Dial Item Selection Selection Selection Selection CO Line No 2 wire 4 wire 6 db 3 db 0 db 3 db 6 db 3 db O db 3 db Yes No Default all Vo xw v i vo all lines 05 TD816 06 SEJE SS 07 os E all lines i i i i i
15. a certain extension receives a high volume of calls compared with other extensions If all extensions in a UCD group are busy or not available the incoming outside call will be handled by the UCD Time Table 24 f Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 3 Features U An outline sketch of UCD is shown below 1 When a number of calls have arrived at a 2 When the Ist call arrives at extension A UCD group the Ist call arrives at the 2nd call arrives at extension B extension A first O lt lt 3rd call in queue Calls have arrived at a UCD group O 2nd call in queue 3rd call in queue O UCD group 2nd call in queue O Extension B Ist call in queue gt q O When extension B is busy or UCD log out has been set to extension B the call arrives at extension C UCD group gt Extension A When extension A is busy or UCD log out has been set in extension A the call arrives at extension B Extension C Extension A y Extension B When extension B is busy or UCD log out has been set in extension B the call 3 When the 2nd call arrives at extension C arrives at extension C the 3rd call will arrive at extension A Extension C
16. caller dials the phone number and the call is forwarded or transferred to extension 1011 of the other PBX which has PBX code 952 Note Setting the destination of Call Forwarding to the TIE line is the same as Call Forwarding to a CO Line Transferring a call to the TIE line is the same as a Call Transfer to a CO Line 13 E 3 Features 2 2 TIE to CO Transfer The system transfers TIE calls to the CO line of the other PBX through the TIE line The following patterns are available E Outside call through the other PBX lt Example gt eee eee ese E E he a E PR DANE E A E EP E R KX TD816 1232 Other PBX TIE Line CO Line DISA E amp M CO 9 DISA TIE User Code phone no PBX Code 951 PBX Code 952 Ext 1011 TIE Line Network Outside party Explanation Extension 1011 dials as follows 1 TIE line access code 7 PBX code 952 and CO line access code 9 and a special dial tone is heard 2 The DISA TIE user code if required and desired phone number Extension 1011 is connected to the desired outside party through the other PBX which has PBX code 952 Note The DISA TIE user code assigned in program 811 is required when the CO line security mode is selected in program 439 E Call Forwarding Call Transfer to CO line lt Example gt KX TD816 1232 Other PB
17. entry examples are 10 and 106 210 and 21 In order not to make an invalid entry check the other extension numbers in programs 003 Extension Number Set 012 ISDN Extension Number Set 118 Voice Mail Extension Number Assignment and 813 Floating Number Assignment Section 3 Features in this manual Phantom Extension 38 4 3 System Programming 131 ISDN DDI Number Phantom Extension Number Transformation Description Selection Default Programming Conditions Feature References Used to convert a DDI number to a phantom extension number in order to put an incoming DDI call to a specific extension e Location number 001 through 128 e DDI Number 1 through 6 digits Blank no number All locations Blank 1 Enter 131 Display Phantom DDI NO 2 Press NEXT Display Location NO gt 3 Enter a location number To enter location number 001 you can also press NEXT Display 001 4 Entera DDI number To delete the current entry press CLEAR 5 Press STORE 6 To program another jack press NEXT or PREV or SELECT and the desired location number 7 Repeat steps 4 through 6 8 Press END e There is a maximum of 128 phantom DDI numbers Each DDI number can be one through six digits consisting of 0 through 9 Section 3 Features in this manual Direct Dialing In DDI 39 220 System Programming TIE First Inter Digit Time Descripti
18. i i 09 10 EE TD1232 12 D 21 Ed ee 23 i E L8 611 616 611 ISDN DDI Number Floating Number Transformation 616 Live Call Screening Recording Mode Assignment Default All not stored Default All not stored Item Selecti Item Selection tem Item election e TO Selection ee Selection e ie Stop R T Keep R a pr Stop R Soen R Ext N 8 Parameter 1 through 6 Ext N Parameter 1 through 6 Ua top Seg i sep Rete Se PSs ai O digits consisting of 0 9 SKS digits consisting of 0 9 Default all Y 32 All jacks i 33 i Operator UCD Gip 1 01 34 Pager 1 UCD Grp 2 02 35 7 03 i 36 i Pager 2 UCD Grp 3 04 i 37 Pager 3 UCD Grp 4 05 38 7 06 39 Pager 4 UCD Grp 5 07 40 i DISA 1 UCD Grp 6 08 i 41 DISA 2 UCD Grp 7 09 10 43 i MODEM UCD Grp 8 11 44 ISDN 1 12 45 lt Note gt 13 i 46 i RENO available for the KX TD1232 14 47 16 49 ISDN 4 17 50 ISDN 5 18 j 51 ISDN 6 19 52 20 53 i ISDN 7 21 34 ISDN 8 22 55 23 56 ISDN 9 24 57 ISDN 10 25 58 26 59 I I ISDN 11 27 60 ISDN 12 28 61 29 62 616 30 63 lt Note gt Jack No TD816 01 16 31 64 TD1232 01 32 for Master 33 64 for S
19. in this manual Voice Mail Integration 68 4 3 System Programming 109 Description Selection Default Programming Expansion Unit Type Assigns the type of expansion units to be used in the system This allows the system to identify the unit in each expansion unit location KX TD816 e Areas 1 2 C 4 CO S1 2 S0 S2 6 S0 EM 4 E amp M E EXT A 16 SLT KX TD1232 e Master Slave e Areas 1 2 3 C 4 CO S1 2 S0 S2 6 S0 EM 4 E amp M El EXT1 E2 EXT2 Al 16 SLT1 A2 16 SLT2 KX TD816 C E KX TD1232 Master and Slave C E1 E2 KX TD816 1 Enter 109 Display Expansion Card 2 Press NEXT Display example Master C E 3 Keep pressing SELECT until the desired selection of Area 1 is displayed 4 Press m to program Area 2 if required 5 Keep pressing SELECT until the desired selection of Area 2 is displayed 6 Press STORE 7 Press END KX TD1232 1 Enter 109 Display Expansion Card 2 Press NEXT to program the Master System To program the Slave press NEXT again Display example Master C E1 E2 69 109 Conditions 43 System Programming Expansion Unit Type 3 Keep pressing SELECT until the desired selection of Area 1 1s displayed 4 Press m to program another Area if required 5 Keep pressing SELECT until the desired selection of the Area is displayed 6 Repeat steps 4 and 5 until all of the re
20. more PBXs which provides cost effective communications between company members at different locations The TIE lines can be used to call through your system to reach another switching system PBX or CO By utilizing TIE lines your system can support not only communications with the public network but with other company locations in the private network where your system is included System Explanation 1 Making a TIE Call One of the following two methods can be used to make a TIE call 1 1 Extension Number method Dial the Extension Number only to make a TIE call lt Example gt KX TD8 16 1232 Other PBX TIE Line E amp M 2011 E af A a A a ae O AE gt Ext 1011 Ext 2011 Explanation To use this method it is necessary to change the first one or two digits of extension numbers of either PBX to avoid having the same extension number 1 Extension 1011 dials extension number 2011 2 Extension 1011 is connected to extension 2011 of the other PBX 11 3 Features 1 2 PBX Code method Dial the TIE Line Access Code PBX Code Extension Number to make a TIE call lt Example gt KX TD8 16 1232 Other PBX TIE Line 7 952 1011 Ext 1011 Ext 1011 Explanation To use this method it is necessary to have each PBX code in order to identify the location of an extension 1 Extension 1011 dials TIE line access code 7 PBX code
21. station access e Floating station KX TD816 Pagerl DTA UCD Grp group 1 through 8 KX TD1232 Pager1 through 4 DISA1 DISA2 MODEM DTA UCD Grp group 1 through 8 e Floating number 2 through 4 digits KX TD816 Pager 1 196 DTA 199 UCD Grp 1 191 UCD Grp 2 192 UCD Grp 3 193 UCD Grp 4 194 UCD Grp 5 291 UCD Grp 6 292 UCD Grp 7 293 UCD Grp 8 294 KX TD1232 Pager 1 196 Pager 2 197 Pager 3 296 Pager 4 297 DISA 1 198 DISA 2 298 MODEM 299 DTA 199 UCD Grp 1 191 UCD Grp 2 192 UCD Grp 3 193 UCD Grp 4 194 UCD Grp 5 291 UCD Grp 6 292 UCD Grp 7 293 UCD Grp 8 294 1 Enter 813 Display FLT EXT NO 2 Press NEXT to program Pager 1 Display example Pagerl EXT196 To program another floating station for KX TD1232 keep pressing NEXT or PREV until the desired floating station is displayed 3 Enter a floating number To change the current entry press CLEAR and enter the new floating number 4 Press STORE 5 To program another floating station keep pressing NEXT or PREV until the desired floating station is displayed 6 Repeat steps 3 through 5 12 Available for the KX TD1232 only 4 8 Resource Programming 413 Floating Number Assignment 7 Press END Conditions e A floating number is composed of two to four numerical digits 0 through 9 e The first one or two digits of the floating numbers are subject to program 100 Flexible Numbering 01
22. until the desired selection is displayed 5 Press STORE 6 To program another CO line group press NEXT or PREV or SELECT and the desired CO line group number 7 Repeat steps 4 through 6 8 Press END To assign all CO line groups to the same selection press the key in step 3 In this case the display shows the contents programmed for CO line group number 1 51 440 Description Selection Default Programming Conditions System Programming TIE Security Type Assigns the security mode for TIE calls There are two modes Non Security and Trunk Security CO line security Non Security mode allows the caller to access a CO line without dialing a TIE user code Trunk Security mode requires the caller to enter a TIE User Code assigned in program 811 DISA TIE User Codes before making a TIE call e CO line group TRG number 1 through 8 x x all CO line groups e Non non security Trunk trunk security Non 1 Enter 440 Display TIE Security 2 Press NEXT Display TRK GRP NO gt 3 Entera CO line group number To enter CO line group number 1 you can also press NEXT Display example TRG1 Non 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 Press END To assign all CO line groups to the same selection press the X key in step 3 In this case the display shows the contents programmed for CO line group number 1 52 System
23. 039 071 103 008 040 072 104 009 041 073 105 010 042 074 106 O11 043 075 107 012 044 076 108 013 045 077 109 014 046 078 110 015 047 079 111 016 048 080 112 017 049 081 113 018 050 082 114 019 051 083 115 020 052 084 116 021 053 085 117 022 054 086 118 023 055 087 119 024 056 088 120 025 057 089 121 026 058 090 122 027 059 091 123 028 060 092 124 029 061 093 125 030 062 094 126 031 063 095 127 032 064 096 128 T8 131 131 ISDN DDI Number Phantom Extension Number Transformation Parameter 1 6 digits consisting of 0 9 Default all Not Stored Item Location Parameter Item Location Parameter Item Location Parameter Item Location Parameter 001 033 065 097 002 034 066 098 003 035 067 099 004 036 068 100 005 037 069 101 006 038 070 102 007 039 071 103 008 040 072 104 009 041 073 105 010 042 074 106 O11 043 075 107 012 044 076 108 013 045 077 109 014 046 078 110 015 047 079 111 016 048 080 112 017 049 081 113 018 050 082 114 019 051 083 115 020 052 084 116 021 053 085 117 022 054 086 118 023 055 087 119 024 056 088 120 025 057 089 121 026 058 090 122 027 059 091 123 028 060 092 124 029 061 093 125 030 062 094 126 031 063 095 127 032 064 096 128 8 340 340 TIE Line Routing Table Item L
24. 1 TR 001 FW Di RM 7 8 An example of a printed meter call record When selected for charge by Program 815 SMDR Output Mode and selected for meter display by Program 120 Charge Display Selection Date Time Ext CO Dial Number Duration Cost Acc code CD 06 24 93 10 03AM 101 01 12345678901234567890 00 05 12 15 1234567890 06 24 93 10 07AM 103 20 lt I gt 0123456789 00 00 56 0 06 24 93 10 08AM 104 10 lt I gt 00 00 20 0 431211 06 24 93 10 08AM 105 10 lt I gt 00 10 01 0 431211 TR 06 24 93 10 09AM 280 14 10222P1 202 346 7890 00 09 18 520 001 FW 06 24 93 10 10AM 103 20 lt I gt 1234567890 00 01 24 0 06 24 93 10 11AM 280 12 lt b gt 00 00 24 0 06 24 93 10 11AM 280 22 0924312111 00 03 02 0 DI 06 24 93 10 20AM 120 13 lt I gt 00 21 46 1040 RM 1 2 O 4 5 6 10 7 8 62 3 Features S Example of SMDR printout format Explanation 1 Date shows the date of the call as Month Day Year 2 Time shows the start time of a call as Hour Minute AM or PM 3 Ext shows the extension number floating number etc that engaged in a call 4 CO shows the CO line number used for the call 5 Dial Number Outgoing call shows the other party s telephone number Regular call record Max 30 digits Charge or Meter call record Max 20 digits Valid digits are O through 9 x P if PAUSE button is pressed or the mark if a host PBX access code is entered Received
25. 33 through 64 Slave Default Master and Slave Blank Programming KX TD816 1 Enter 117 Display VMS Port Asn 2 Press NEXT Display example M 3 Enter a jack number To delete the current entry press CLEAR To change the current entry press CLEAR and enter the new jack number 4 Press m to enter another jack number 5 Repeat steps 3 through 4 to enter another jack number 6 Press STORE S Press END KX TD1232 1 Enter 117 Display VMS Port Asn 2 Press NEXT to program the Master System To program Slave press NEXT again Display example M A f Available when the Digital Super Hybrid System is connected to a Digital 29 Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 117 43 System Programming Voice Mail Number Assignment Conditions Feature References Ge Enter a jack number To delete the current entry press CLEAR To change the current entry press CLEAR and enter the new jack number 4 Press mp to enter another jack number 5 Repeat steps 3 through 4 to enter another jack number 6 Press STORE 7 Press NEXT to program the Slave System Display example S 4 8 Repeat steps 3 through 4 to enter another jack numbers 9 Press END e Neither Jack number 01 nor the manager extension can be assigned as a voice mail port jack The voice mail port jac
26. 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 Press END To assign all CO lines to one selection press the X key in step 3 57 616 4 8 Extension Programming Live Call Screening Recording Mode Assignment Description Selection Default Programming Conditions Feature References Assigns whether to close the mailbox or to continue recording the conversation after a call is intercepted e Jack number KX TD816 01 through 16 x KX TD1232 01 through 64 x all jacks Stop Record Keep Record All jacks Stop Record Stop recording 1 Enter 616 Display LCS Rec Mode 2 Press NEXT Display Jack NO gt 3 Enter a jack number To enter jack number 01 you can also press NEXT Display example 01 Stop Record 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 To program another jack number press NEXT or PREV or SELECT and desired jack number 7 Repeat steps 4 through 6 8 Press END e For the KX TD1232 jack numbers 01 through 32 are for the Master System and 33 through 64 are for the Slave if available e For an explanation of jack numbering see Rotation of jack number on page 4 7 in the main installation manual e To assign all jacks to the same selection press the X key at step 3 In this case the display shows the contents programmed for jack 01 Section 3 Features in th
27. 6 None 74 Other PBX Extension 07 None 75 Other PBX Extension 08 None 76 Other PBX Extension 09 None 77 Other PBX Extension 10 None 78 Other PBX Extension 11 None 79 Other PBX Extension 12 None 80 Other PBX Extension 13 None 81 Other PBX Extension 14 None 82 Other PBX Extension 15 None 83 Other PBX Extension 16 None 84 LCS password set cancel 799 85 log in log out 45 For the programming sequence and more information refer to the program 100 Flexible Numbering in the main Installation Manual 66 f Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 4 3 System Programming Description Selection Default Programming 106 Station Hunting Type Used to enable or disable hunting and set the Station Hunting type for each extension group There are six Station Hunting types available Circular Termination Voice Mail VM Automated Attendant AA and Uniform Call Distribution UCD If circular hunting is assigned for a group all the extensions in the group are hunted until an idle one is found If termination hunting is assigned hunting stops at the extension which has the largest jack number in the group If VM hunting is assigned all the VM ports of an extension group are hunted until an idle one is found which permits Voice Mail Service If A
28. 7 952 xxxx Lt gt qo b 7 953 xxxx a 952 xxxx c 2xx Ext IXxx pex Code 951 PBX Code 952 Pat Xxxx 7 TIE line access code 3 Features TIE Line Routing Table of PBX 1 Location PBX Code Removed Added co Line Group Hunt Sequence No Ext No Digit Digit 01 02 03 04 05 01 952 0 5 6 02 953 0 6 5 03 2xx 0 7 Explanation Location 01 The hunt sequence by dialing 7 PBX Code 952 The Ist route CO line group TRG 5 The 2nd route CO line group TRG 6 Location 02 The hunt sequence by dialing 7 PBX Code 953 The Ist route CO line group TRG 6 The 2nd route CO line group TRG 5 Location 03 The hunt sequence by dialing Ext no 2xx The Ist route CO line group TRG 7 If the received number does not match the PBX Code the system checks the number in the routing table If it is found the system automatically sends the number to the corresponding PBX For example if PBX 1 receives the number 952 xxxx from PBX 4 PBX 1 automatically sends the number through CO line group 5 4 TIE Call Dialing Method The following patterns are TIE call dialing methods The dial number modification depends on the dialing method Your telephone Dialing Method Dial Modification APT DPT Extension no Enable CO button PBX code Extension no Disable TIE line access code PBX code Extension no Enabl
29. 93 06 24 93 06 24 93 06 24 93 06 24 93 06 24 93 06 24 93 a 10 03AM 10 07AM 10 08AM 10 08AM 10 09AM 10 10AM 10 11AM 10 11AM 10 20AM 2 104 3 CO Dial Number Duration Acccode CD 01 123456789012345678901234567890 00 05 12 1234567890 20 lt INCOMING gt 0123456789 00 00 56 10 lt INCOMING gt 00 00 20 431211 10 lt INCOMING gt 00 10 01 431211 TR 14 10222P1 202 346 7890 00 0918 001 FW 20 lt INCOMING gt 1234567890 00 01 24 12 lt INCOMING gt 00 00 24 22 0924312111 00 03 02 Di 13 lt INCOMING gt 00 21 46 RM 4 5 6 7 8 61 3 Features An example of a printed charge call record When selected for charge by Program 815 SMDR Output mode and selected for charge display by program 120 Charge Display Selection Date 06 24 93 06 24 93 06 24 93 06 24 93 06 24 93 06 24 93 06 24 93 06 24 93 06 24 93 Time 10 03AM 10 07AM 10 08AM 10 08AM 10 09AM 10 10AM 10 11AM 10 11AM 10 20AM Ext 101 103 104 105 280 103 280 280 120 Dial Number 12345678901234567890 lt I gt 0123456789 lt b gt lt I gt 10222P 1 202 346 7890 lt I gt 1234567890 lt I gt 0924312111 lt I gt 5 Duration 00 05 12 00 00 56 00 00 20 00 10 01 00 09 18 00 01 24 00 00 24 00 03 02 00 21 46 6 Cost 382 81KC 0 00KC 0 00KC 0 00KC 560 00KC 0 00KC 0 00KC 128 00KC 0 00KC 9 Acc code CD 1234567890 431211 43121
30. 952 and extension number 1011 2 Extension 1011 is connected to extension 1011 of the other PBX which has PBX code 952 2 TIE Line and CO Line Connection To connect the TIE line with the CO line the following patterns are available 2 1 CO to TIE Transfer The system transfers incoming outside calls to the other PBX through the TIE line The following patterns are available E TIE call using DISA lt Example gt KX TD8 16 1232 Other PBX CO Line TIE Line CO 7 DISA TIE User Code DISA 952 1011 PBX Code 952 phone no E dp Sh edi ie dy ih Elk O gt Outside party TIE Line Network Ext 1011 12 3 Features E Explanation The outside caller dials as follows 1 The DISA phone number and the DISA OGM is sent 2 TIE line access code 7 and a dial tone is heard 3 The DISA TIE user code if required PBX code 952 and extension number 1011 The outside caller is connected to extension 1011 of the other PBX which has PBX code 952 E Call Forwarding Call Transfer to the TIE line lt Example gt KX TD816 1232 Other PBX CO Line CO E amp M Forwarded Transferred PBX Co to 952 1011 PBX Code 952 phone no 4 gt Outside party Ext 1011 Ext 1011 TIE Line Network Explanation The outside
31. A hunting is assigned all the AA ports of an extension group are hunted until an idle one is found which permits AA Service If UCD is assigned group members are hunted in a circular way e Extension group number 1 through 8 x x all extension groups Disable no hunting Terminate termination Circular VM voice mail AA automated attendant UCD All extension groups Disable 1 Enter 106 Display Call Hunting 2 Press NEXT Display EXT GRP NO gt 3 Enter an extension group number To enter extension group number 1 you can also press NEXT Display example Groupl Disable 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 To program another extension group press NEXT or PREV or SELECT and the desired extension group number 7 Repeat steps 4 through 6 8 Press END 67 106 Conditions Feature References 4 3 System Programming Station Hunting Type e Program 602 Extension Group Assignment is used to assign the extension group members e The system supports a maximum of eight jacks 16 jacks during System Connection for KX TD1232 for connection to a Voice Processing System as VM or AA ports e To assign all extension groups to the same selection press the key at step 3 In this case the display shows the contents programmed for extension group 1 Section 3 Features Station Hunting Uniform Call Distribution UCD
32. Conditions System Programming Voice Level Receive Assigns the received voice level on a CO line basis This program is valid only when the voice path type is set to 4 wire e CO line number KX TD816 05 through 08 X all CO lines KX TD1232 09 through 12 Master 21 through 24 Slave X all CO lines e 6 db 3 db 0 db 3 db All CO lines 3db 1 Enter 444 Display Voice Level RX 2 Press NEXT Display CO Line NO gt 3 Enter a CO line number To enter CO line number 09 you can also press NEXT Display example CO09 3db 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 Press END To assign all CO lines to one selection press the X key in step 3 56 System Programming 445 Description Selection Default Programming Conditions TIE Receive Dial Assigns whether the system receives TIE dial numbers on a CO line basis If No is selected the dialed number is treated as a local number and sent to DIL 1 1 or DIL 1 N e CO line number KX TD816 05 through 08 x all CO lines KX TD1232 09 through 12 Master 21 through 24 Slave X all CO lines e Yes No All CO line ports Yes 1 Enter 445 Display TIE Receive Dial 2 Press NEXT Display CO Line NO gt 3 Enter a CO line number To enter CO line number 09 you can also press NEXT Display example CO09 Yes
33. IE features If this assignment is changed it affects other programming 432 through 436 e To assign all CO line groups to the same selection press the key in step 3 In this case the display shows the contents programmed for CO lind group number 1 43 432 Description Selection Default Programming Conditions System Programming TIE Incoming Assignment Assigns a TIE incoming method immediate or wink to each TIE table according to your central office service Immediate Incoming TIE calls can be received right after the receiving signal arrives Wink Incoming TIE calls can be received after the wink signal is transmitted to the central office after the receiving signal arrives TIE table number 1 to 4 x all TIE tables e Immediate Wink All DID TIE tables Wink 1 Enter 432 Display TIE Signal In 2 Press NEXT Display Table NO 3 Enter a TIE table number To enter TIE table number 1 you can also press NEXT Display example 1 Wink 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 To program another TIE table press NEXT or PREV or SELECT and the desired TIE table number 7 Repeat steps 4 through 6 8 Press END To assign all TIE tables to one selection press the key in step 3 In this case the display shows the contents programmed for TIE table number 1 44 System Programming 433 Description Selec
34. Panasonic Digital Super Hybrid System KX TD816CE KX TD1232CE Added and Changed Features for Installation Manual and Programming Tables Vol 3 Please read this manual first and then the Installation Manual In this manual the last letter CE of each model number is omitted ROM Version KX TD816CE P341A KX TD1232CE P24 1B and later versions Table of Contents Additions to KX TD816 1232 Section 1 System Outline 1 4 Options E amp M LIB Tete Unit a dacs 4 Section 2 Installation 2 4 Installation of Optional Cards and Units E amp M TIE Line Unit Connect ea reinas 5 Installing Expansion Unit OKX TDISA A 6 Section 3 Features Automatic CONUS UTA ON veritas 10 E amp M TIE Line Service sanieren decantan alacena ieee 11 ARAS NO 20 Logan Together EES ENEE EES 22 Phantom EXtension i llei asocia 23 Two Way Recording into the Voice Mal 24 Uniform Call Distribution UCD 24 Voice Mail Integration for Digital Proprietary Telephones nono cnncnnoos 28 Section 4 System Programming 117 Voice Mail Number Asstenment ceeceeeecceseceececsseeecceeeeeeneceececeaeceaeeceeessaeeeeeesaeeeeaeceeeecaeeeaeees 29 118 Voice Mail Extension Number Asatgnment rr rrereecereceeeaceraneeracreneenanees 31 119 Voice Mail Extension Group Assignment cee eeceecesceseceeceseeeeceeeeeeeeseecsecseecsecsaecsecnaeeseesaeenees 33 126 UCD Overflow AA ON 34 127 UCD Time KEE 35 128 PBX Cod laica 36 129 E amp M
35. RI 13 ORN RED 25 3 NO3 E Lead 38 ORN BLK 26 3 SG Lead 14 YEL RED 27 3 SB Lead 39 YEL BLK 28 3 MI Lead 15 GRY RED 29 3 SGO 40 GRY BLK 30 3 M Lead only for Type 5 16 WHY RED 31 4 T 3 Al WHY BLK 32 4 R 2 wire or 4 wire send 17 ORN RED 33 4 Tl 4 wi wire receive 42 ORN BLK 34 4 R1 18 YEL RED 35 4 E Lead 43 YEL BLK 36 4 Nog SG Lead 19 GRY RED 37 4 SB Lead 44 GRY BLK 38 4 MI Lead 20 WHY RED 39 4 SGO 45 WHY BLK 40 4 M Lead only for Type 5 Note 21 25 46 50 Cannot be connected Installing Expansion Unit KX TD184 EH Cable Pins to be Connected E amp M Line e E amp M Line Wiring 50 pin Connector Block Terminal 3 3 2 5 8 O E amp MLinel 6 6 7 7 O 8 8 O 9 9 CO so Ty 11 1 AFO El Bridging Clips E Connecting to another KX TD816 KX TD1232 system KX TD184 1 2 wire voice path KX TD184 Another KX TD184 To oT RA RR E E SG SG SB SB 2 4 wire voice path KX TD184 Another KX TD184 T T R R T1 T1 R1 R1 E E M1 i M1 SB SB Installing Expansion Unit KX TD184 EH Connecting to the E amp M Central Office 1 2 wire voice path KX TD184 E amp M Central Office GROUND GROUND 2 4 wire voice path KX TD184 Another KX TD184 Voice Transmit 3 z Voice Receive 48V Voice gt Receive no lt Voice CO E EIS emi
36. Signal Assignment ssis ienesa i apa e EER EE EEEE EEEE EEE SEELEN 37 130 Phantom Extension Number Asatgnment er rercrreceraccerncaraceernceenacananes 38 131 ISDN DDI Number Phantom Extension Number Transformation 39 220 TIE First Inter Digit Tame Zeen erg Ae edert O 40 340 TIE Line AAA ds 41 341 TIE Modify Removed Digit Added Dal 42 431 TIE Table Number Asetenment csceececescesceceececsseeeecensecesaecescecsaeceaceceeecsaeeeneesseeeeeeceeeecsaeeeneees 43 432 TEE 44 433 TIE Outgoms ASsignMent c0ic cscs dolencias spnosieecdsosnsctecvna ii is gear 45 434 TIE Subscriber Number Removed ue 46 435 TIE Added Number diia aca 47 436 TIE Wink Time Out Assignment 20 0 0 ceeceescesceceececsseeeeceeseeeeneceseeceaeceseeceeecsaeeeeeesseeeeaeceeeessaeeeaee ss 48 437 1COsto IE Trasteros esse ads eee ES 49 ESTI AA 50 439 TIE tO TIE Transfer nr e ones oe 51 440 TIE eh EE 52 441 Line Hunting Sequence r ea rea eE recono neon ener on none nan none ran non nr non ron enn concern concen nera ia 53 442 e Vice Paths Type ca fair 54 443 Voice Level Transmit ccccccccsccecsssecessececsesececsececeeseeecesaececesaecesaeeecesaeceseaeeseseeesesaeseseaaeeeseeseeeaes 55 4441 Voice Level Rec iii anki heen oe casa 56 445 TIE Receive Dial A A A EEEN 57 616 Live Call Screening Recording Mode Asatgmment non nonnc on nora con ncn nero ncnnoo 58 Changes Section 3 Features Station Message Detail Reco
37. TIE Table Number Assignment TIE Incoming Assignment TIE Outgoing Assignment TIE Subscriber Number Removed Digit TIE Added Number TIE Wink Time Out Assignment CO to TIE Transfer TIE to CO Transfer TIE to TIE Transfer TIE Security Type Line Hunt Sequence Voice Path Type Voice Level Transmit Voice Level Receive TIE Receive Dial Call Transfer to CO Line Call Forwarding to CO Line DISA TIE User Codes System Additional Information Field 41 19 L 3 Features Live Call Screening LCS Description Allows a digital proprietary telephone user to monitor his her voice mailbox while an incoming caller is leaving a message and if desired intercept the call The voice mailbox can be monitored in one of two ways Hands free or Private Hands free Mode The voice mailbox is monitored through the built in speaker of the proprietary telephone Private Mode When callers are connected to a voice mailbox a proprietary telephone user will hear an alert tone To monitor the call the user goes off hook on the handset or speakerphone Alert Tone i i i i i i Lef ls y 1 f E E i i E M E E i i i l l l l l l l l l l l l l l i To intercept the call in either Hands Free or Private mode press the LCS button A single line telephone which is connected with a proprietary telephone in parallel can be also used to monitor a recording message Be sure that the Live C
38. X CO Line 7 952 1011 Forwarded Transferred GEERT Ext 1011 Ext 1011 i Outside party TIE Line Network A A A A IA 14 3 Features E Explanation Extension 1011 dials as follows 1 TIE line access code 7 PBX code 952 and extension number 1011 2 The call is forwarded or transferred by extension 1011 of the other PBX which has PBX code 952 to the designated CO line 3 TIE Line Routing Table The TIE Line Routing Table is referenced by the system to identify the CO line route when an extension user makes a TIE call It is necessary to make unified routing tables with each PBX in your TIE line network A routing pattern appropriate for each call is decided by the first three digits except the TIE line access code of the dialed number There are two system programs for the tables 340 TIE Line Routing Table used to assign the access number PBX code or extension number and CO line group hunt sequence 341 TIE Modify Removed Added Digit used to assign removed and added digits of the dialed digits of the TIE call Programming Example lt Example gt Your system is PBX 1 and there are four PBXs in your TIE line network To identify the CO line route as illustrated below you should make the following routing table EE Ext 2xx PBX Code 953 Ext xxxx TRG7 b 953 xxxx If you dial a
39. a 48V GROUND GROUND Installing Expansion Unit KX TD184 E E amp M Sequences You can choose one of the following E amp M sequences by System Programming 129 E amp M Signal Assignment 1 Continuous E amp M T UUU N E Wire Wink M Wire If you select Immediate this signal will not appear 2 Pulsed E amp M with Answer signal ep do o Pk ACK M Wire Answer signal zs If you select this sequence then you must select Wink as the start type 3 Pulsed E amp M without Answer signal E Wire Ir Mio f L ACK M Wire zs If you select this sequence then you must select Wink as the start type A 3 Features Automatic Configuration Description The system sends the VPS data which contains the extension number configuration information and the VPS automatically creates mailboxes with this data Quick Setup Conditions e The data is transmitted to the VPS on the lowest jack port Programming References No programming required Feature References None Operation References Not applicable 10 Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 3 Features E E amp M TIE Line Service Description An E amp M TIE line is a privately leased communication line between two or
40. all Screening on the connected proprietary telephone has been activated This feature is useful when you are out with a portable handset of a cordless telephone SLT The handset emits an alert tone to let you know that a message is being recorded To intercept the call flash the hookswitch Conditions If the extension user is having a conversation a call waiting tone is sent The user can put an existing call on hold before accessing LCS e A flexible CO and DSS button can be assigned as a Live Call Screening button e To prevent unauthorized monitoring a three digit password must be set by the LCS user If the user forgets his password it can be cleared by the operator or manager e Each extension can be programmed to either close the mailbox or continue recording the conversation after the call is intercepted 20 f Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 3 Features L Programming References Section 4 System Programming in this manual 005 Flexible CO Button Assignment 616 Live Call Screening Recording Mode Assignment Station Programming Added and Changed Features for User Manual Vol 4 Flexible Button Assignment Live Call Screening Button Live Call Screening Cancel Button Live Call Screening Mode Set Feature References None Operat
41. an arrive at an extension in log in status within the UCD group but cannot arrive at extensions in log out status If the extension would like to leave the group temporarily the extension sets the log out status by the feature number to prevent UCD calls being sent to their extensions When the extension re joins the group the extension sets the log in status e There should be at least one extension that is in log in status Programming References Section 4 System Programming in this manual 106 Station Hunting Type 126 UCD Overflow 127 UCD Time Table 611 ISDN DDI Number Floating Number Transformation 813 Floating Number Assignment 27 U V 3 Features Feature Reference Section 3 Features Extension Group Station Hunting Log In Log Out in this manual Operation References DPT Features SLT Features Added and Changed Uniform Call Distribution UCD Features for User Manual Vol 4 Voice Mail Integration for Digital Proprietary Telephones Description A Digital Proprietary Telephone capable Panasonic Voice Processing System can be connected to a Digital Super Hybrid System DSHS in a tightly integrated fashion The system sends the VPS data which contains the extension number configuration information and the VPS automatically creates mailboxes with this data Automatic Configuration Quick Setup Conditions e A maximum of one VPS can be connected to each DSHS cabinet e A maximum of
42. as the corresponding Phantom button A phantom button can be assigned by Station Programming e Types of calls whose destination can be the phantom extension are Outside calls DIL 1 1 DDI IRNA UCD Overflow Intercom calls Extension Transfer e You can call the phantom extension by pressing the Phantom button or by dialing the phantom extension number If several extensions have the same phantom extension number they will ring simultaneously A phantom number must be assigned by System Programming before assigning the Phantom button by Station Programming There is a maximum of 128 phantom numbers Each number has two to four digits consisting of numbers 0 through 9 The phantom number cannot be used for feature settings such as Call Forwarding The lighting patterns and status of the Phantom button are shown below Lighting pattern Phantom Extension Status Off Idle Red on Calling a phantom extension Green rapid flash Incoming call A DSS button can be assigned as the Phantom button so that the operator can use the button for transferring a call Programming References Feature References Section 4 System Programming in this manual 130 Phantom Extension Number Assignment Station Programming Added and Changed Features for User Manual Vol 4 Flexible Button Assignment Phantom Button None Operation References DPT Features Added and Changed Phantom Extension Features for U
43. assigned in program 213 DISA Delayed Answer Time e Dialing is disregarded during an OGM e In sequence assignment Sx can be assigned in a space other than the first only when another Sx is assigned in the first space e In sequence assignment an assignment after TR RT or Blank is not available e An OGM is only available for KX TD1232 e If a timer is the first item in a Time Table sequence it will delay answering according to the Timer s time setting The caller will hear a ringback tone e Music on Hold after an OGM can be changed to a ringback tone by program 990 System Additional Information Field 1 Conditions e UCD can be used in the following cases a The floating number of UCD is assigned as the DIL 1 1 destination b The floating number of UCD is assigned as the Intercept Routing destination c The floating number of UCD is dialed from an extension d The floating number of UCD is dialed from DISA e The floating number of UCD is assigned as the UCD Overflow destination f The floating number of UCD is assigned as the Direct Dialing In destination This feature requires assignment of a UCD group in System Programming An extension cannot belong to two or more UCD groups The floating number can be assigned on a UCD group basis The UCD group is based on the extension group It is possible to set the log in or log out status on an extension basis A UCD call c
44. call shows lt INCOMING gt and lt I gt If the call is carried by an ISDN network also shows the telephone number of the calling party 6 Duration shows the duration of the call as Hours Minutes Seconds 7 Acc Code Account Code shows the account code appended to the call 8 CD Condition Code shows call handling type with the following codes TR Transfer FW Call Forwarding to CO Line DO Non Security CO Line Access using DISA D1 through D4 DISA User Codes 1 through 4 RM Remote access to a modem To print out the record of System Programming items that have been assigned use the program 802 System Data Printout 9 Cost shows the charge 10 Cost shows the meter Conditions e Connect a printer provided with an EIA RS 232C interface to the EIA RS 232C connector located on the main unit e When programmed for outgoing toll calls only printing occurs only for calls which start with the numbers stored in any Denied Code Table from levels 2 to 6 If ARS is employed not the user dialed but modified number is checked against these tables Available for KX TD1232 only 63 S 3 Features e This system can store information on up to 100 calls If more calls are originated or received previous records are deleted starting from the oldest one e This data is not deleted when you reset the system e If the system clock is not set by System Programming or if the calendar IC is out of order th
45. ce mail port programmed in 117 1 of YY 1 means the first part of jack number in digital line Y Y 2 means the second part of the jack number in digital line To assign all voice mail numbers to the same selection press the key in step 3 In this case the display shows the contents programmed for TIE table number 1 Section 3 Features in this manual Voice Mail Integration for Digital Proprietary Telephones f Available when the Digital Super Hybrid System is connected to a Digital 33 Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 126 Description Selection Default Programming Conditions Feature Reference 4 3 System Programming UCD Overflow Assigns the destination where the call is transferred to when all extensions in the UCD group are busy The Time Table number of the overflow extension must also be assigned e UCD group number 1 through 8 e Overflow extension number 2 through 4 digits e Time table number 1 through 4 All UCD groups Not stored 1 Enter 126 Display UCD Overflow 2 Press NEXT Display UCD NO gt 3 Enter an UCD group number To enter UCD group number 1 you can also press NEXT Display example UCDI y TT 4 Enter an overflow extension number Display example UCD1 102 TT 5 Press wb 4 Enter a time table number Display example UCD1 102 TT 1 4
46. ch area Default See Default shown in the lists 75 Programming Tables for Added and Changed Features 8L 100 126 127 100 Flexible Numbering 126 UCD Overflow Ttem Feature Default Parameter Parameter 7 TTE line access code None UCD Group No Overflow Extension Time Table Lt None _ No 2 4 digits No 1 4 69 Other PBX Extension 02 None Default all Not Stored 70 Other PBX Extension 03 None 1 71 Other PBX Extension 04 None 0 72 Other PBX Extension 05 None 1 73 Other PBX Extension 06 None 1 74 Other PBX Extension07 None sO 75 Other PBX Extension08 None 76 Other PBX Extension09 None 0 77 Other PBX Extension 10 None 78 Other PBX Extension 11 None 9 Other PBX Extension 12 None 127 UCD Time Table 80 Other PBX Extension 13 None 81 Other PBX Extension 14 None si SS Sequence g2 OtherPBXExtension1S None 83 Other PBX Extension 16 None Table 1 e 7 Ei 84 LCS password set cancel 799 J 85 UCDlog in log out 45 EE Ei R ER Selection No 67 1 3 digits Valid Entries 0 9 No 68 83 1 or 2 digits Valid Entries 0 9 Table Wa e ad No 84 85 1 3 digits Valid Entries 0 9 X t Table 4 S gt RE q Sud Selection S1 S2 S3
47. d and DPT Integration disable AA service mode enable The mode will change to the VM service mode and a Follow On ID 1s sent When the voice mail port is in VM service mode this program is not affected 40 Selects the result when a CO call is routed 0 Enable 1 Voice Mail to a voice mail port by IRNA For both 1 Disable Integration Inband and DPT Integration When the voice mail port is in VM service mode enable VM service mode disable The mode will change to the AA service mode Only when Inband When the voice mail port is in AA service mode enable The mode will change to the VM service mode and a Follow On ID 1s sent disable AA service mode 41 Enables or disables sending CO line access 0 Enable 1 None code 9 to a TIE line When you dial CO 1 Disable line access code 9 and the CO line is busy the system can automatically send CO line access code 9 to a TIE line so that you can access the CO line through another PBX 74 4 10 Optional Programming 990 System Additional Information The Selection section is changed as follows Selection e Area code 01 area 1 02 area 2 03 area 3 04 area 4 05 area 5 06 area 6 1 e Field number 1 through 22 26 and 36 for areas 1 and 2 23 through 25 and 27 for areas 3 and 4 28 through 34 and 37 for area 5 35 and 38 through 41 for area 6 e Selection See Selection shown in the lists for ea
48. e CO button PBX code TIE user code Phone no Disable TIE line access code PBX code TIE user code Enable Phone no Select CO line group PBX code Extension no Disable Select CO line group PBX code TIE user code Disable Phone no 16 3 Features E Your telephone Dialing Method Dial Modification SLT Extension no Enable TIE line access code PBX code Extension no Enable TIE line access code PBX code TIE user code Enable Phone no Select CO line group PBX code Extension no Disable Select CO line group PBX code TIE user code Disable Phone no In addition to the methods above the system can use the TIE line for sending CO line access code 9 through other PBX When you dial the CO line access code and the CO line is busy the system automatically sends CO line access code 9 to a TIE line so that you can access the CO line through other PBX This is enabled by program 990 System Additional Information Field 41 5 TIE Line Routing Flow Chart Making a TIE Call from an Extension A TIE call is made as follows PBX Code Method 7 abc xxxx Extension No Method dexx y Is the dialed number identified with the stored Not treated as a TIE numbers Checks in program 100 call Yes TIE line access code 7 Other PBX extension no de No Reorder tone
49. e date and time is not printed out e If FLASH Signal is manually sent out during a conversation the call record is printed and a new record is started Connection References Section 2 Installation 2 3 10 Printer Connection Programming References Section 4 System Programming 000 Date and Time Set 120 Charge Display Selection in this manual 212 Call Duration Count Start Time 800 SMDR Incoming Outgoing Call Log Printout 801 SMDR Format 802 System Data Printout 806 807 EIA RS 232C Parameters 815 SMDR Out put Mode in this manual 990 System Additional Information Field 38 Ea kel kel kel kel kel Feature References None Operation References Not applicable 64 4 2 Manager Programming 005 Flexible CO Button Assignment Description As the new features are added the assignable flexible buttons are changed as shown below Selection e Jack number KX TD816 01 through 16 KX TD1232 01 through 64 e Button Code plus parameter if required Button Code Parameter 0 Single CO KX TD816 01 through 08 CO line number KX TD1232 01 through 24 CO line number 1 DSS 2 through 4 digits Extension number 2 One Touch 16 digits max Telephone number 3 Message Waiting None 4 FWD DND None 5 Save None 6 Account None 7 Conference None 80 Log In Log Out None 82 Voice Mail Transfer 2 through 4 digits Extension number 83 Two Way Record
50. enter the new number 5 Press STORE 6 To program another TIE table press NEXT or PREV or SELECT and the desired TIE table number 7 Repeat steps 4 through 6 8 Press END Each added number has a maximum of 4 digits consisting of 0 through 9 47 436 Description Selection Default Programming Conditions System Programming TIE Wink Time Out Assignment The TIE outgoing method can be set to the wink mode in program 433 TIE Outgoing Assignment This program sets the time the system waits for the confirmation wink signal after a CO line is seized according to your central office service The system disconnects the CO line when the time out expires TIE table number 1 to 4 X all TIE tables e Time 1 through 127 x 64 milliseconds is the actual time All TIE tables 16 1 Enter 436 Display TIE Wink Timeout 2 Press NEXT Display Table NO 3 Entera TIE table number To enter TIE table number 1 you can also press NEXT Display example 1 16 4 Enter the time To change the current entry press CLEAR and enter the new number 5 Press STORE 6 To program another TIE table press NEXT or PREV or SELECT and the desired TIE table number 7 Repeat steps 4 through 6 8 Press END e You cannot leave the entry empty e To assign all TIE tables to one selection press the X key in step 3 In this case the display shows the contents programmed for TIE table nu
51. four DSHS jacks can be connected to a digital proprietary telephone capable VPS Because a digital proprietary telephone connection supports up to two simultaneous voice calls only one DSHS jack needs to be connected to two VPS ports e Connect the jacks and ports in ascending order In other words the lowest number DSHS jack used for VPS connection must be connected to the lowest number VPS port e The VPS data is transmitted to the VPS via the lowest jack port Programming References Section 4 System Programming in this manual 117 Voice Mail Number Assignment 118 Voice Mail Extension Number Assignment 119 Voice Mail Extension Group Assignment 616 Live Call Screening Recording Mode Assignment Feature References Section 3 Features Voice Mail Integration Operation References Not applicable 28 f Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 4 2 System Programming 117 Voice Mail Number Assignment Description Assigns the jack number corresponding to the voice mail port for data transmission to the Voice Processing System The voice mail port is expandable to four ports 8 ports during System Connection for KX TD1232 Selection KX TD816 e Jack number 02 through 16 KX TD1232 e M Master S Slave e Jack number 02 through 32 Master
52. gram 439 enabled Enable No No Is the corresponding extension idle Is there a hunt sequence assignment Checks in program 340 l Yes No Calls an extension A ringback tone is sent Calls an extension Call Waiting Reorder tone e Busy tone Did you employ the CO line security mode Checks in program 440 li Yes Is a DISA TIE user code received Programs in program 811 Yes Routes to a CO or TIE line Local TRG routing 18 3 Features E Conditions e It is possible to program the E amp M signal voice path type and voice level transmit receive of the E amp M Line Unit by system programming For details about the E amp M signal voice path type and voice level refer to Installation in this manual e The FLASH button does not function as the disconnection key e The ability to perform Call Forwarding Call Transfer to TIE line is determined on a Class of Service basis See programs 503 and 504 Programming References Section 4 System Programming 100 109 128 129 220 340 341 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 503 504 811 990 LL Flexible Numbering Expansion Unit Type PBX Code E amp M Signal Assignment TIE First Inter Digit Time TIE Line Routing Table TIE Modify Removed Added Digit
53. he beginning of the received digits Selection e TIE table number 1 to 4 e Number of digits to be deleted 0 through 6 O no deletion Default All TIE tables 0 Programming 1 Enter 434 Display TIE Remove Digit 2 Press NEXT Display Table NO gt 3 Entera TIE table number To enter TIE table number 1 you can also press NEXT Display example 1 1 4 Enter the number of digits to be deleted To change the current entry press CLEAR and the new number 5 Press STORE 6 To program another TIE table press NEXT or PREV or SELECT and the desired TIE table number 7 Repeat steps 4 through 6 8 Press END Conditions You cannot leave the entry empty 46 System Programming 435 Description Selection Default Programming Conditions TIE Added Number Assigns the added number to the TIE subscriber number which is determined in program 434 TIE Subscriber Number Removed Digit This makes the final number which serves as the extension number Note that digits are inserted at the beginning of the number e TIE table number 1 to 4 e Number to be added 4 digits max All DID TIE tables Not Stored 1 Enter 435 Display TIE Add Dial 2 Press NEXT Display Table NO gt 3 Enter a TIE table number To enter TIE table number 1 you can also press NEXT Display example 1 2 4 Enter the number to be added To change the current entry press CLEAR and
54. ion References DPTe Features Added and Changed Live Call Screening LCS Features for Operator Service Features User Manual Vol 4 Live Call Screening Password Control 21 L Log In Log Out Description Conditions 3 Features Assigns an extension to join log in or leave log out a hunting or UCD group Extensions in log out status receive no calls by Station Hunting but can receive other calls unlike the DND feature e There should be at least one extension that is in log in status e The lighting patterns of Log In Log Out button and the status are shown below lighting CO Line Status pattern UCD Station Hunting Red on Log Out Log Out Red flash Log In waiting calls off Log In no calls Log In no calls Programming References Feature References Operation References Section 4 System Programming in this manual 100 Flexible Numbering UCD log in log out Station Programming Added and Changed Features for User Manual Vol 4 Flexible Button Assignment Log In Log Out Button Section 3 Features Station Hunting Uniform Call Distribution UCD in this manual DPT Features SLT Features Added and Changed Log In Log Out Features for User Manual Vol 4 22 3 Features P Phantom Extension Description Conditions Allows the system to route the calls to a phantom extension A call to a phantom extension arrives at an extension who h
55. is manual Live Call Screening LCS Voice Mail Integration for Digital Proprietary Telephones 58 f Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 Changes FEATURE TITLE Station Message Detail Recording SMDR SECTION OF THE MANUAL Installation Manual Section 3 REVISION This feature has been changed to the new one See pages 61 through 64 005 Flexible CO Button Assignment Installation Manual Section 4 The Selection section is changed as shown on page 65 100 Installation Manual The new features have been added See page 66 for Flexible Numbering Section4 details 106 Installation Manual This program has been changed to the new one See Station Hunting Type Section 4 pages 67 and 68 109 Installation Manual This program has been changed to the new one See Expansion Unit Type Section 4 pages 69 and 70 611 Installation Manual The Selection section has been changed as follows ISDN DDI Number Section 4 e Floating Station Operator Pager 1 Pager 2 Floating Number Pager 3 Pager 4 DISA 1 Transformation DISA 2 MODEM ISDN 01 ISDN 02 ISDN 03 ISDN 04 ISDN 05 ISDN 06 ISDN 07 ISDN 08 ISDN 09 ISDN 10 ISDN 11 ISDN 12 UCD Grp 1 UCD Grp 2 UCD Grp 3 UCD
56. jack number in digital line Section 3 Features in this manual Voice Mail Integration for Digital Proprietary Telephones 32 f Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 4 2 System Programming 119 Voice Mail Extension Group Assignment Description Selection Default Programming Conditions Feature References Assigns each voice mail number to a voice mail extension group number e Voice mail number VM KX TD816 01 through 08 x KX TD1232 01 through 16 x x all voice mail number e Voice mail extension group number EXG 1 through 8 All voice mail numbers EXG 1 1 Enter 119 Display VM EXT Group Asn 2 Press NEXT Display VM NO gt 3 Enter a voice mail number To enter voice mail number 01 you can also press NEXT Display example VM 01 02 1 EXG1 4 Enter the voice mail extension group number To delete the current entry press CLEAR To change the current entry enter the new number 5 Press STORE 6 To program another voice mail number press NEXT or PREV or SELECT and the desired voice mail number 7 Repeat steps 4 through 6 8 Press END e The display shows VM XX Y Y 1 EXG Z in step 3 XX means a voice mail number Y Y means the jack number of the voi
57. k cannot be assigned to a manager extension e The jack numbers correspond to the voice mail port in numerical order Example Stored jack numbers Jacks 02 03 05 08 Jack 02 Voice mail numbers 01 02 Jack 03 Voice mail numbers 03 04 Jack 05 Voice mail numbers 05 06 Jack 08 Voice mail numbers 07 08 None 30 f Available when the Digital Super Hybrid System is connected to a Digital Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 4 2 System Programming IIS Voice Mail Extension Number Assignment Description Assigns the extension number for the voice mail number These numbers can be used the same way extension numbers are used for station access Selection e Voice mail number VM KX TD816 01 through 08 KX TD1232 01 through 16 Extension Number 2 through 4 digits Default KX TD816 VM 01 165 VM 02 166 VM 03 167 VM 04 168 VM 05 169 VM 06 170 VM 07 177 VM 08 178 KX TD1232 VM 01 165 VM 02 166 VM 03 167 VM 04 168 VM 05 169 VM 06 170 VM 07 177 VM 08 178 VM 09 171 VM 10 172 VM 11 173 VM 12 174 VM 13 175 VM 14 176 VM 15 179 VM 16 180 Programming 1 Enter 118 Display VM EXT NO Set Di Press NEXT Display VM NO gt 3 Enter a voice mail number To enter voice mail number 01 you can also press NEXT Display VM 01 02 1 165 4 Enter an extension number To change the cur
58. lave 88 813 990 813 990 System Additional Information Floating Number Assignment AREA 06 Fields 35 and 38 through 41 Selection Field Unused 41 40 39 Unused Item Default Ce Default ba ils p 2 through 4 digits Selection Pager 1 196 lt Selection gt Pager 2 197 SS S l g ee geed printed out Pager 3 296 39 0 Disable 1 Enable er E eee DISA1 198 DISA2 298 MODEM 299 DTA 199 UCD Grp 01 191 UCD Grp 02 192 UCD Grp 03 193 UCD Grp 04 194 UCD Grp 05 291 UCD Grp 06 292 UCD Grp 07 293 UCD Grp 08 294 813 lt Note gt Available for KX TD1232 only 68 811 811 DISA TIE User Codes Default Parameter Default Parameter Item Code COS 4 to 10 digits COS 1 8 Item Code COS 4 to O digits COS 1 8 Code 1 0001 1 Code 17 0017 1 Code 2 0002 1 Code 18 0018 1 Code 3 0003 1 Code 19 0019 1 Code 4 0004 1 Code 20 0020 1 Code 5 0005 1 Code 21 0021 1 Code 6 0006 1 Code 22 0022 1 Code 7 0007 1 Code 23 0023 1 Code 8 0008 1 Code 24 0024 1 Code 9 0009 1 Code 25 0025 1 Code 10 0010 1 Code 26 0026 1 Code 11 0011 1 Code 27 0027 1 Code 12 0012 1 Code 28 0028 1 Code 13 0013 1 Code 29 0029 1 Code 14 0014 1 Code 30 0030 1 Code 15 0015 1 Code 31 0031 1 Code 16 0016 1 Code 32 0032 1
59. le 22 AWG Under 9 6 km 3 Transmission levels 2 wire voice D th 3 db transmit receive 4 wire voice path 3 db normal transmit receive Programmable 6 db 3 db O db 3 db 4 Signaling DTMF or Pulse 5 E lead Battery 48 VDC 20 mA to ground max Sensitivity 5 mA or 2000 Q to ground max min 6 M lead Available current 30mA max Available voltage 100V max 2 4 Installation of Optional Cards and Units E amp M TIE Line Unit Connection Note Step 6 Installing one unit to the system allows four E amp M TIE lines to be connected to CO lines 05 through 08 for the KX TD816 or CO lines 09 through 12 or 21 through 24 for the KX TD1232 This unit can be installed to any of the expansion areas provided on the front of the system For unit installation refer to the procedure Section 2 4 4 Installing Expansion Unit KX TD170 KX TD180 in the main Installation Manual Steps 1 through 5 and 7 through 10 of the installation procedure are the same as other expansion units Step 6 is different for each unit Please note the following instructions below instead of step 6 Installation Manual for this unit e System Programming 109 Expansion Unit Type is required for expansion unit location identification E If the KX TD184 is installed use an Amphenol Connector to connect the E amp M TIE lines Insert the connector into the jack Connector type 50 pin Amphenol 57JE series or
60. ly when another Sx is assigned in the first space e An assignment after TR RT or Blank is not available Section 3 Features in this manual Uniform Call Distribution UCD Available for KX TD1232 only 35 128 Description Selection Default Programming Conditions 4 3 System Programming PBX Code Assigns the PBX Code as your location number if the PBX Code method is employed for TIE Line Network calling PBX Code 1 to 3 digits Not Stored 1 4 5 Enter 128 Display PBX Code Press NEXT Display Code Enter a PBX Code To change the current entry press CLEAR and enter the new code Press STORE Press END Valid numbers for the PBX Code are 0 through 9 The PBX Code method is PBX Code Extension number 36 4 2 System Programming 129 E amp M Signal Assignment Description Selection Default Programming Conditions Assigns the E amp M signal There are three signals available Continuous Continuous E amp M Wink Immediate Pulsed Ans Pulsed E amp M with Answer Signal Wink only Pulsed No Ans Pulsed E amp M without Answer Signal Wink only Continuous Pulsed Ans Pulsed No Ans Continuous 1 4 5 Enter 129 Display E amp M Signal Press NEXT Display example Continuous Keep pressing SELECT until the desired selection is displayed Press STORE Press END If you select Pulsed An
61. mber 1 48 System Programming 437 Description Selection Default Programming Conditions CO to TIE Transfer Enables or disables transferring an incoming outside call to the TIE line on a CO line group basis This restriction applies to the following 1 A TIE call using DISA 2 Call Forwarding to a TIE line 3 Call Transfer to a TIE line e CO line group TRG number 1 through 8 x X all CO line groups e Enable Disable All CO line groups Disable 1 Te 8 Enter 437 Display CO TIE Transfer Press NEXT Display TRK GRP NO gt Enter a CO line group number To enter CO line group number 1 you can also press NEXT Display example TRG1 Disable Keep pressing SELECT until the desired selection is displayed Press STORE To program another CO line group press NEXT or PREV or SELECT and the desired CO line group number Repeat steps 4 through 6 Press END To assign all CO line groups to the same selection press the key in step 3 In this case the display shows the contents programmed for CO line group number 1 49 438 Description Selection Default Programming Conditions System Programming TIE to CO Transfer Enables or disables transferring TIE calls to a CO line on a CO line group basis This restriction applies to the following 1 An outside call through another PBX 2 Call Forwarding to a CO line 3 Call Transfer to a CO line e
62. n NO gt 3 Enter a location number To enter location number 01 you can also press NEXT Display example 01 0 4 Enter the number of digits to be deleted To change the current entry press CLEAR and enter the new number 5 Press m to program the number to be added 6 Enter the number to be added To change the current entry press CLEAR and enter the new number 7 Press STORE 8 To program another location press NEXT or PREV or SELECT and the desired location number 9 Repeat steps 4 through 8 10 Press END Conditions Each added number has a maximum of 4 digits consisting of O through 9 42 System Programming 43 TIE Table Number Assignment Description Assigns a TIE table number to each CO line group Selection e CO line group TRG number 1 through 8 x all CO line groups e TIE table number 1 to 4 Default All CO line groups Not stored Programming 1 Enter 431 Display TIE Table NO 2 Press NEXT Display TRK GRP NO gt 3 Entera CO line group number To enter CO line group number 1 you can also press NEXT Display example TRG1 Not Stored 4 Enter a TIE table number To change the current entry press CLEAR and the new number 5 Press STORE 6 To program another CO line group press NEXT or PREV or SELECT and the desired CO line group number 7 Repeat steps 4 through 6 8 Press END Conditions e This is the first and basic programming for the T
63. ocation No Parameter TIE line access code 3 digits max consisting of 0 9 x Parameter CO line group hunt sequence no 1 8 5 entries max Item Location No Parameter TIE line access Parameter CO line group hunt code 3 digits max consisting of 0 9 x sequence no 1 8 5 entries max Default all Not Stored Not Stored Default all Not Stored Not Stored all locations 17 ElsSlojelajaftujajoln m a N he LA D a Nn hn O v8 341 341 TIE Modify Removed Digit Added Dial Parameter Parameter No to be added Parameter Parameter No to be added Item No of digits to be deleted 4 digits max consisting of Item No of digits to be deleted 4 digits max consisting of Location No 0 4 0 9 Location No 0 4 0 9 Default all 0 Not Stored Default all 0 Not Stored all locations 17 1 18 2 19 3 20 4 21 3 22 6 23 7 24 8 25 9 26 10 27 11 28 12 29 13 30 14 31 15 32 16 68 431 433 437 441 431 TIE Table Number 437 CO to TIE 438 TIE to CO 439 TIE to TIE Assignment Transfer Transfer
64. on Assigns the maximum time allowed between the start of the dial tone and the first digit dialed First Digit Time and between digits Inter Digit Time on an TIE call If an extension user fails to dial any digits during this time the DTMF receiver is released This timer applies until the Toll Restriction check is completed Selection Time seconds 3 to 30 Default 10s Programming 1 Enter 220 Display TIE Timer 2 Press NEXT Display example Time 10 sec 3 Enter the time To change the current entry press CLEAR and enter the new time 4 Press STORE 5 Press END Conditions e This timer is used for toll restriction checking e You cannot leave the entry empty Feature References Section 3 Features Toll Restriction 40 System Programming 340 Description Selection Default Programming Conditions TIE Line Routing Table The TIE line routing table can be programmed This table is referenced by the system to identify the CO line route when an extension user makes a TIE call A routing pattern appropriate for each call is decided by the first three digits except the TIE line access code of the dialed number This program assigns the TIE line access code and CO line group hunt sequence e Location number 01 through 32 e TIE line access code 1 to 3 digits e CO line group hunt sequence number 1 through 8 5 entry max All locations Not stored 1 Enter 340 Display example TIE Route
65. quired entries are completed if required 7 Press STORE If only one system is in operation go to step 10 8 Press NEXT to program the Slave System Display example Slave C E1 E2 9 Repeat steps 3 through 7 if required 10 Press END e Each parameter corresponds to an expansion unit as follows C KX TD180 S1 KX TD280 S2 KX TD286 E El and E2 KX TD170 A Al and A2 KX TD174 EM KX TD184 There are two expansion areas in the KX TD816 areas 1 and 2 from bottom to top Either one 8 Station Line Unit or 16 SLT Line Unit and either one 4 CO Line Unit 4 E amp M Line Unit 2 ISDN SO Line Unit or 6 ISDN SO Line Unit can be installed e There are three expansion areas in each system for the KX TD1232 areas 1 2 and 3 from bottom to top Either up to two 8 Station Line Units or 16 SLT Line Units and either one 4 CO Line Unit 4 E amp M Line Unit 2 ISDN SO Line Unit or 6 ISDN SO Line Unit can be installed in each system e An out of service system is unassignable In this case skip steps 8 and 9 for the KX TD1232 e For the KX TD1232 if only the Slave System is in operation the display shows Slave in step 2 e After changing the setting turn the Power Switch off and on once Otherwise the previous setting will remain 70 4 9 Resource Programming 811 Description Selection Default Programming Conditions DISA TIE User Codes Assigns the DISA and TIE User Codes and a Class of Se
66. rding SMDR A 60 61 Section 4 System Programming 005 Flexible CO Button Assignment eeen a i ei e A a i 60 65 100 Flexible Numbering o ei it 60 66 106 Station Hunting Types aE aa erie rio eA EE EEE EEEE EEEa E ESSES 60 67 109 Expansion Unit Nype cas cse mise cegus cries iesse rires iosep EEr cvs SEE esas dicta s 60 69 611 ISDN DDI Number Floating Number Transformation cooooccnoccconcconnncnonconnnonnncnnnnonnncnnnccnnnronnccnnnnos 60 811 ICH NNN EBEN 60 71 813 Floating Number Aestenment cee cecesecsecsseeseceseeecescesecnseeseseeeeseseaeeseecsessaecaecsaecaecaeeseenaeeaees 60 72 990 System Additional Information Fields 39 through 41 eee 60 74 Programming Tables for Added and Changed Features 000001011111111111115111111510 77 2 Additions to KX TD816 1232 14 Options E amp M TIE Line Unit KX TD184 This unit can be used for E amp M Line Service and has four ports c Four ports for E amp M Line Service can be added Specifications 1 E amp M TIE Line Types Type 5 only 2 Transmission ooococcncnonoononnnonncnnnonnnononcnnonananoss 2 wire or 4 wire voice path Programmable Note Maximum cabling distance of the E amp M line cord twisted cab
67. rent entry press CLEAR and enter the new number 5 Press STORE 6 To program another voice mail number press NEXT or PREV or SELECT and the desired voice mail number 7 Repeat steps 4 through 6 8 Press END f Available when the Digital Super Hybrid System is connected to a Digital 31 Proprietary Telephone capable Panasonic Voice Processing System one that supports digital proprietary telephone integration e g KX TVP200 118 43 System Programming Voice Mail Extension Number Assignment Conditions Feature References You cannot leave an entry empty The first one or two digits of the voice mail extension numbers are subject to program 100 Flexible Numbering 01 through 16 1st through 16th hundred extension blocks Double entries and incompatible entries for extension numbers are invalid Valid entry examples are 10 and 11 10 and 110 Invalid entry examples are 10 and 106 210 and 21 In order not to make an invalid entry check the other extension numbers in programs 003 Extension Number Set 012 ISDN Extension Number Set 130 Phantom Extension Number Assignment and 813 Floating Number Assignment The display shows VM XX Y Y 1 ZZZ in step 3 XX means the voice mail number Y Y means the jack number of the voice mail port programmed in 117 1 of YY 1 means the first part of jack number in digital line YY 2 means the second number of the
68. rvice COS to each code The code COS determines the toll restriction level of the DISA and TIE caller e DISA TIE user code number 01 through 32 e DISA TIE user code 4 to 10 digits e COS number 1 through 8 Code 01 0001 COS 1 Code 02 0002 COS 1 Code 03 0003 COS 1 Code 32 0032 COS 1 pu Enter 811 Display User Code 2 Press NEXT Display User Code NO gt 3 Enter a DISA TIE user code number To enter user code number 01 you can also press NEXT Display example 01 0001 Est 4 Enter a DISA TIE user code To change the current entry enter the new code 5 Press mp to program the COS 6 Entera COS number To change the current entry enter the new COS number 7 Press STORE 8 To program another user code press NEXT or PREV or SELECT and the desired DISA TIE user code number 9 Repeat steps 4 through 8 10 Press END e This setting is required if the Trunk CO line Security mode is selected in programs 440 TIE Security Type and 809 DISA Security Type e Each user code should be unique and composed of eight numerical digits 0 through 9 You cannot leave an entry empty 71 813 4 9 Resource Programming Floating Number Assignment Description Selection Default Programming Assigns the floating numbers for External Pagers DISA messages modem and UCD groups These numbers can be used the same way extension numbers are used for
69. s or Pulsed No Ans you must select Wink as the start type 37 130 4 3 System Programming Phantom Extension Number Assignment Description Selection Default Programming Conditions Feature References Assigns the phantom numbers Each number will be assigned to a flexible CO or DSS button and used as a Phantom button e Location number 001 through 128 e Phantom number 2 through 4 digits All locations Not stored 1 Enter 130 Display Phantom NO 2 Press NEXT Display Location NO gt 3 Enter a location number To enter location number 001 you can also press NEXT Display example 001 Not Stored 4 Enter a phantom number To delete the current entry press CLEAR To change the current entry press CLEAR and enter the new number 5 Press STORE 6 To program another location press NEXT or PREV or SELECT and the desired location number 7 Repeat steps 4 through 6 8 Press END e There is a maximum of 128 phantom numbers Each number has two to four digits consisting of numbers 0 through 9 e The first one or two digits of the phantom extension numbers are subject to program 100 Flexible Numbering 01 through 16 Ist through 16th hundred extension blocks e Phantom extension numbers and other extension numbers should be unique Double entry and incompatible entry for these numbers are invalid Valid entry examples are 10 and 11 10 and 110 Invalid
70. ser Manual Vol 4 23 T U 3 Features Two Way Recording into the Voice Mail Description Allows a proprietary telephone user to record the conversation into one s mailbox or another mailbox while talking on the phone Note When you record Two Way telephone conversations you should inform the other party that the conversation is being recorded Conditions e A flexible CO and DSS button can be assigned as a Two Way Record button or a Two Way Transfer button e When all the voice mail ports are busy pressing the Two Way Record button sends an alarm tone e When all the voice mail ports are busy pressing the Two Way Transfer button followed by an extension number sends an alarm tone Programming References Section 4 System Programming in this manual 005 Flexible CO Button Assignment Station Programming Added and Changed Features for User Manual Vol 4 Flexible Button Assignment Two Way Record Button Two Way Transfer Button Feature References None Operation References DPT Features Added and Changed Two Way Recording into the Voice Mail Features for User Manual Vol 4 Uniform Call Distribution UCD Description Allows incoming calls CO line extension to be distributed uniformly to a specific group of extensions called UCD group Calls to a UCD group hunt for an idle station in a circular way starting at the extension following the last one called This UCD feature is particularly helpful when
71. the equivalent 25 1 50 26 To terminal Board from the E amp M TIE Line e Be sure to secure the inside screw or the unit may not work properly e To fix the connector refer to Section 2 4 4 Installing Expansion Unit KX TD170 KX TD180 Amphenol 57 Type screw attach type 50 pin connector Connection for KX TD170 in the main Installation Manual e For jack connection please see Cable Pin Numbers to Be Connected on the next page e The KX TD1232 is illustrated above Installing Expansion Unit KX TD184 EH Cable Pins to be Connected E amp M Line e nnect Cable Color Clip No e E amp M Line l ORIYRED l E 2 wire or 4 wire send 26 ORN BLK 2 1 R 2 YEL RED 3 1 T1 4 wi wire receive 27 YEL BLK 4 1 RI 3 GRY RED 5 1 NO 1 E Lead 28 GRY BLK 6 1 SG Lead A WHY RED H 1 SB Lead 29 WHY BLK 8 1 MI Lead 5 ORN RED 9 1 SGO 30 ORN BLK 10 1 M Lead only for Type 5 6 YEL RED a a E 2 wire or 4 wire send 31 YEL BLK 12 2 R 7 GRY RED 13 2 Tl 4 wi wire receive 32 GRY BLK 14 2 RI 8 WHY RED 15 2 E Lead 33 WHY BLK 16 2 NO 2 SG Lead 9 ORN RED 17 2 SB Lead 34 ORN BLK 18 2 MI Lead 10 YEL RED 19 2 SGO 35 YEL BLK 20 2 M Lead only for Type 5 11 GRY RED 21 3 T a 36 GRY BLK 22 3 R 2 wire or 4 wire send 12 WHY RED 23 3 Tl 4 wi wire receive 37 WHY BLK 24 3
72. through 16 1st through 16th hundred extension blocks e Floating numbers and extension numbers should be unique Double entry and incompatible entry for these numbers are invalid Valid entry example 10 and 11 10 and 110 Invalid entry example 10 and 106 210 and 21 In order not to make an invalid entry check the other extension numbers in programs 003 Extension Number Set 012 ISDN Extension Number Set 118 VM Extension Number Assignment and 130 Phantom Extension Number Assignment The default of each extension number is as follows 003 Extension Number Set KX TD816 101 through 116 201 through 216 KX TD1232 101 through 164 201 through 264 012 ISDN Extension Number Set Not stored 118 VM Extension Number Assignment 165 through 180 130 Phantom Extension Number Assignment Not stored You cannot leave an entry empty Feature References Section 3 Features Floating Station 73 990 4 10 Option Programming System Additional Information Description Field 39 40 and 41 are added to Area 6 Area 6 Display sample EEN y bli y LN Field number unused 41 40 39 unused 38 35 Explanation for Area 6 Field Description Selection Default Reference 39 Selects the result when a CO call is routed 0 Disable 1 Voice Mail by Call Forwarding to a voice mail port 1 Enable Integration which is in AA service mode For both Inban
73. tion Default Programming Conditions TIE Outgoing Assignment Assigns a TIE outgoing method immediate or wink to each TIE table according to your central office service Immediate Outgoing TIE numbers can be transmitted right after seizing the CO line Wink Outgoing TIE numbers can be transmitted after receiving the wink signal from the central office after seizing the CO line e TIE table number 1 to 4 x all TIE tables e Immediate Wink All TIE tables Wink 1 Enter 433 Display TIE Signal Out 2 Press NEXT Display Table NO 3 Enter a TIE table number To enter TIE table number 1 you can also press NEXT Display example 1 Wink 4 Keep pressing SELECT until the desired selection is displayed 5 Press STORE 6 To program another TIE table press NEXT or PREV or SELECT and the desired TIE table number 7 Repeat steps 4 through 6 8 Press END e The time the system waits for the confirmation wink signal can be programmed in program 436 TIE Wink Time Out Assignment The system disconnects the CO line when the time out time expires e To assign all TIE tables to one selection press the X key in step 3 In this case the display shows the contents programmed for TIE table number 1 45 434 System Programming TIE Subscriber Number Removed Digit Description Assigns the removed digits of the received TIE subscriber numbers to each TIE table Digits are removed from t