Home
        INSTALLATION MANUAL
         Contents
1. BE SURE ONLY TO  USE ACCESSORIES MADE BY DAIKIN THAT ARE  SPECIFICALLY DESIGNED FOR USE WITH THE  EQUIPMENT AND HAVE THEM INSTALLED BY A  PROFESSIONAL     IF UNSURE OF INSTALLATION PROCEDURES OR USE   ALWAYS CONTACT YOUR DAIKIN DEALER FOR ADVICE  AND INFORMATION        INTRODUCTION    Thank you for purchasing the EKAC10B address card     This address card will enable you to communicate with your chiller  through a Building Management System or supervisory system   Please refer to the Gateway Installation Manual for more information  and a detailed overview of how the communication works     OR    This address card will enable you to connect a remote user interface   Please refer to the installation manual of the remote user interface  EKRUMC for more detailed information     CHILLER RANGE    This specific address card is designed to function with chillers of the  ranges according to the following table     Range Models Connection Switchbox    EUWA5 12H  Z   EUWY5 10H  Z   EUW5 24HZ  EUWL5 24HZ    Refer to figure 4a    56 51 on terminale Omega rail available    Refer to figure 4a    2   EUWAC5 10FZ 50 51 on terminals    Omega rail available       EUWANS 24KZ  EUWAP5 24KZ    EUWAB5 24KZ Refer to figure 4b    Refer to figure 5a          3 G and GO Installation possible  EUWYN5 24KZ l  EUWYP5 24KZ on I O PCB of omega rail  EUWYB5 24KZ   A Refer to figure 4b Refer to figure 5b  4 E e G and GO Installation possible  on I O PCB of omega rail  Refer to figure 4b  EUW16 24KZ l   5 EUW
2. DAIKIN       INSTALLATION MANUAL    Address card       EKAC10B             Serial module EA  Tj                 Uchiller             Cn          mil    G GO  L power supplv 4                Serial module                   Uchiller                                                                      rd  OO                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                   f a  s  7      4 a e  AH J f E  Z Ann   d  An l 5  J    ag oa    ANa ce    i  Ada T l H  ATA  el E       p i e i  4  dae E mija    JW   mel E   JALI mm A  je 7  i al  SL                                                                                                       DAIKIN    EKAC10B    Address card       T READ THIS MANUAL ATTENTIVELY BEFORE STARTING  UP THE UNIT  DO NOT THROW IT AWAY  KEEP IT IN  YOUR FILES FOR FUTURE REFERENCE     IMPROPER INSTALLATION OR ATTACHMENT OF  EQUIPMENT OR ACCESSORIES COULD RESULT IN  ELECTRIC SHOCK  SHORT CIRCUIT  LEAKS  FIRE OR  OTHER DAMAGE TO EQUIPMENT  
3. L16 24KZ G and GO Omega rail available   on I O PCB                      YOUR ADDRESS CARD KIT    The kit you have just purchased consists of    mM 1 address card  type EKAC10B    B 1 connection wire to controller   B 1 connection wire   1 connection wire with fuse  power supply   B 1omegarail   2 screws    Installation manual    DESCRIPTION OF THE ADDRESS CARD    Measurements     refer to figure 1     Connections on the address card    There are three connections to be made    B to the chillers controller   B power supply   B if the kit is used in combination with gateway  connect to the  serial line of the gateway  OR    if the kit is used in combination with the remote user interface   connect to the remote user interface       A Before starting up the unit for the first time  make sure that  it has been properly installed  It is therefore necessary to  read the installation manual supplied with the unit and the  recommendations listed in    Checks before initial start up     carefully        HOW TO INSTALL THE ADDRESS CARD        A Turn the power off before installing the address card        Install the address card    For range 3 and 4 only    Install the omega rail on the foreseen space  range 3  refer to figure 5a  range 4  refer to figure 5b    For all ranges   refer to figure 2     Place the address card on the upper side of the omega rail  then  push the bottom side of the address card until you hear a clicking  sound  The address card is now locked onto the omega r
4. ail     If you want to remove the address card because it was installed  incorrectly  follow this procedure     1 Pull down the grey lip at the bottom of the address card  using a  screwdriver     2 Keep the lip down and pull the bottom side of the address card  backwards     3 Raise the address card and release the lip        EKAC10B  Address card  4PW16026 1A    DAIKIN    Installation manual    Connect the address card to the controller     refer to figure 3     Use the grey connection wire to connect the address card to the  controller     1 Push the crimp terminal of the connection wire in the 7 pin  header on the upper side of the address card     2 Unplug the wire in the right upper corner at the back of the  controller  This way you will create enough space to plug in the  connection wire     3 Push the crimp terminal on the other side of the connection wire  in the 7 pin header at the back of the controller  The 7 pin  header is called the serial line on the figure at the top of the  controller     4 Plugin the wire you removed to create enough space back in the  top right corner at the back of the controller     Connect the address card to the transfo    For ranges 1 and 2 only   refer to figure 4a     Use the connection wire and the connection wire with fuse to connect  the address card to the transfo     1 Connect screw connection 11 GO on the address card to  terminal 50 on the main rail  Use the supplied connection wire  without fuse     2 Connect screw connectio
5. ctive  0   not active  18 r ri Warning  defrost cvcle not completed 1   warning  0   no warning  19 r A1 Alarm  anti freeze 1  alarm  0   no alarm  21 r EO Alarm  supply voltage is high 1  alarm  0   no alarm  22 r EU Alarm  supply voltage is low 1  alarm  0   no alarm  25 r Output of pump 1   on  0   off  26 r Output of compressor 1 1   on  0   off  28 r Output of reversing valve     1   on  0   off  29 r Output of alarm 1   on  0   off  30 r Output of fan 1   on  0   off        31 r Input of high pressure or discharge protector or overcurrent alarm 1  closed  0   open  32 r Input of low pressure switch alarm 1  closed  0   open  33 r Input of remote on off 1  closed  0   open  34 r Output of compressor 2  b  1   on  0   off  40 r w  d Measurement unit of temperature 0   C 1   F  47 r w H7 Enable disable    remote on off  digital input 1   enable  0   disable  55 r w H6 Enable disable  remote cooling heating  digital input 1   enable  0   disable  57 r n2 Warning  compressor 2 requires maintenance  b  1  warning  0   no warning                          a  Only if model is mentioned in range 1   b  Only available for units with 2 circuits    Integer variables    Parameter    Direct  Comment  Address User Description Unit of measurement       Time delay between the pump startup and compressor startup Seconds                     13 r w c8 Time delay between unit shutdown and the pump shutdown Minutes  14 r c9 Total running hours of the compressor 1 Hours x 100  15 r w cb Timer 
6. e to the chiller s address card     Digital variables          NOTE For the possible values of a direct or user parameter   ch refer to the chiller operation manual                                      Parameter Comment  Water cooled  chillers  Air cooled Air cooled se  20   chillers chillers    ou  Direct  i Remote  User Description ma lk Condenser  1 r w Cooling or heating 1   cooling  0   heating  2 r w On or off 1   On  0   off  5 r H1 Alarm  high pressure or discharge protector or overcurrent 1   alarm  0   no alarm  6 r LI Alarm  evaporating temperature thermostat 1   alarm  0   no alarm  8 r FL Alarm  flow switch 1   alarm  0   no alarm  9 r E3 Alarm Ambient Col i E inlet  temperature  2    temperature  2   temperature  10 r E2 Alarm Water evaporator outlet temperature  11 r E1 Alarm Water evaporator inlet temperature  12 r n1 Warning  compressor requires maintenance 1   warning  0   no warning       13 r EP Alarm  EEPROM defective    1   alarm  0   no alarm                      14 r EE Alarm  EEPROM defective          1   alarm  0   no alarm        a  Only if model is mentioned in range 1       Installation manual    DAIKIN    EKAC10B  Address card  4PW16026 1A    Parameter Comment    Water cooled                                                                   chillers  Air cooled Air cooled Bua  Read  Direct  at mne     Address Write User Description e A  Condenser  15 r EL Alarm  power supply has remarkable noise 1  alarm  0   no alarm  17 r d1 Defrost cycle 1   a
7. n 12 G on the address card to terminal  51 on the main rail  Use the supplied connection wire with fuse     For ranges 3  4 and 5 only   refer to figure 4b     1 Connect screw connection 11 GO on the address card to  terminal GO on the I O PCB  Use the supplied connection wire  without fuse     2 Connect screw connection 12 G on the address card to terminal  G on the I O PCB  Use the supplied connection wire with fuse     HOW TO OPERATE THE ADDRESS CARD WITH  THE GATEWAY     Connect the address card to the gateway or to a  different address card    You have two possibilities     B If the chiller is the first in line or the only one to connect to a  gateway  connect it to the gateway directly     B lf the chiller is a chiller in line and not the first one in line   connect it to another chiller     For more information  consult the following documents    B The chiller operation manual  Defining the unit   s serial address   B Installation manual of gateway    B Operation manual of gateway     HOW TO OPERATE THE ADDRESS CARD WITH  THE REMOTE USER INTERFACE     Read more on this in the installation manual of the remote user  interface EKRUMC        THE VARIABLES DATABASE only for use with Gateway    The BMS or supervisory system and the address card communicate  through a fixed set of variables  also called address numbers   Hereafter  you will find the information you need about the digital   integer and analog variables that the BMS or supervisory system can  read from or writ
8. threshold for maintenance warning Hours x 100       Total running hours of the pump Hours x 100                   piece coco  lt i                      32 r w P4 Enable or disable buzzer   38 r w H9 Lock of user  amp  direct parameters O   keyboard disabled  1   keyboard enabled  39 r HA Serial address   51 r Hg Software release   99 r CA   Total running hours of the compressor 2  2  Hours x 100        a  Only available for units with 2 circuits    Analog variables  Unit of measurement    C x 1 10                                                           Parameter Comment  Water cooled  chillers  Air cooled Air cooled se  chillers chillers k 38  Direct  m Remote  Address User Description jk A Condenser  1 r Analog input 1 Water evaporator inlet temperature  2 r Analog input 2 Water evaporator outlet temperature    Ambient Coil Water    3 r Analog input 3  a   a    condenser inlet  temperature temperature  temperature  10 r w D ri Cooling setpoint  11 r w D r2 Cooling difference  12 r w D r3 Heating setpoint      13 r w D r4 Heating difference       a  Only if model is mentioned in range 1  EKAC10B DAIKIN Installation manual  Address card 3    4PW16026 1A    DAIKIN EUROPE NV    Zandvoordestraat 300  B 8400 Oostende  Belgium APWEN16026 1A    
    