Home
Diver-Mate user manual
Contents
1. indicated in the figure below The cap can be removed from the main body This will allow the connection of the USB cable and removal of the SD card Under the cap are two more LEDs The functions of these LEDs are indicated in the figure below page 1of3 Schlumberger WATER SERVICES DDC connector Red LED Low battery indicator BAT LOW Red LED Error downloading Diver data ERROR Green LED Finished downloading Diver data Ok Yellow LED Busy downloading Diver data DATA Red LED Battery charging CHARGE Main body Yellow LED Connection to PC Memory card BUS miniSD USB connector Cap mini USB Type B 5 pin Using the Diver Mate Use the instrument as follows Charging the Diver Mate Connect the Diver Mate with a PC using the supplied USB cable Leave the Diver Mate connected for 5 hours completely empty battery Downloading data from a Diver to a Diver Mate Keep the cap on the Diver Mate to assure that it is waterproof IP 86 30 minutes for 1 meter Connect the Diver Mate to the DDC The Diver Mate will recognize it is connected to a DDC will start reading the data yellow DATA LED blinking If no Diver is connected to the DDC the error LED will light up after 10 seconds Disconnecting the Diver Mate from the DDC cable will stop the yellow LED from blinking and will also stop the data download from the Diver the Diver Mate will then go into sleep mode The green
2. to 99 as file name The extension is DAT example 12767 01 DAT In case there is already data from one particular Diver on the card the newly generated file will have a higher sequence number The newly generated sequence number will always be higher than the highest found corresponding serial number lf data was not properly downloaded it will be stored in the format seria number xx ERR example 32196 01 ERR The supplied SD card can store more than 1 000 Diver full memory downloads Once the SD card is full data can be deleted as with a normal USB memory stick through a file accessing software Battery With a fully charged battery many Divers can be read approx 500 Divers with full memory The battery is charged when connected to the PC with the USB cable The red LED CHARGE next to the mini USB connector indicates charging When the red LED turns off the battery is fully charged page 3 of 3
3. LED OK is turned on when the download is successfully completed The red LED ERROR will be turned on o if an error occurred during data download or o ifthe Diver Mate is disconnected during reading or page 2 of 3 Schlumberger WATER SERVICES o if no Diver is connected to the DDC or o ifthe SD card is not inserted in the Diver Mate All LEDs are turned off when the Diver Mate is disconnected from the DDC The Diver Mate will go into sleep mode to preserve power Downloading data from the Diver Mate to a PC e Remove the cap e Insert the SD card into a PC or alternatively connect the Diver Mate with a PC using the USB cable The connected SD card or the Diver Mate will act as a USB memory stick If the Diver Mate is connected to a PC the yellow LED BUS will be turned on This indicates that the PC has recognized the unit as a portable disk e With a file accessing software such as Windows Explorer you can copy the stored DAT files anywhere or use Diver Office to download these DAT files into Diver Office and or export them directly to any location as MON files For more details please see the manual of Diver Office LDM can also be used to import the Diver Mate DAT files Data storage The Diver data is stored on a miniSD memory card which is provided with the Diver Mate The data is stored in the format serial number xx DAT using the serial number of the Diver serial number 5 characters and a sequence number xx 01
4. Schlumberger WATER SERVICES Diver Mate user manual The Diver Mate is an instrument which can be used to retrieve data from a Diver in the field The Diver Mate supports the following Diver data loggers e DI7xx Cera Diver measures temperature and groundwater level e DI6xx Micro Diver measures temperature and groundwater level e DI5xx Mini Diver measures temperature and groundwater level e DI24x MTD Diver measures temperature and groundwater level e DI250 DI500 Baro Diver measures barometric pressure and temperature e DI26x CTD Diver measures conductivity temperature and groundwater level The Diver must be connected to a DiverDataCable DDC Upon connection with a DDC the Diver Mate will automatically download the data from the connected Diver This data is stored on a 2 gigabyte memory card miniSD inside the Diver Mate The SD card can be removed from the Diver Mate and inserted into a card reader Alternatively data can also be read by connecting the Diver Mate with the supplied USB cable type USB A to mini USB B 5 pin to a PC Upon connection with a USB cable the battery of the Diver Mate will also be charged Knowing the Diver Mate The Diver Mate see the figure below consists of 3 parts e the main body e the cap e the memory card Two sets of 4 LEDs lights one set on each side of the main body indicate the status and operation of the Diver Mate The functions of these LEDs are
Download Pdf Manuals
Related Search
Related Contents
Gebruiksaanwijzing Vario 6000-8000 Deutsch - Schuss Home Electronic Copyright © All rights reserved.
Failed to retrieve file