Home
User Manual
Contents
1. 002 Camera cable MIC004 VGA cable MICOO05 Video cable MICOO06 S Video cable MICO07 IR sensor 008 Remote control MICO10 Docking Station power adapter MICO12 Holder PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera 05528 Wired Docking Station Installation VGA to Monitor If Video Out to TV Monitor t 1 S Video to TV Monitor 1 10 4 Model No MN DS529 With Video S Video Accessories 001 Barrier MICOO2 Camera cable MICOO5 Video cable MICOO06 S Video cable MICOO7 IR sensor 008 Remote control MICO10 Docking Station power adapter MICO12 Holder PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera 05529 Wired Docking Station Installation jp mS 11 E 5 Model No MN DS510 Built in Type with Video S Video Accessories 001 Barrier MIC002 Camera cable MICOO05 Video cable MICOO06 S Video cable MICOO07 IR sensor 008 Remote control MICO10 Docking Station power adapter MICO12 Holder MICO13 Cable PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera DS510 Wired Docking Station Installation Video Out to TV Monitor S Video to TV Monitor cable EEG NOTE The Built in type is designed to be installed inside the dental unit 12 DOCKING
2. TM3 Dimensions L x W x H 5 3cm x 6 6cm x 1 7cm Receiving Channels Frequency 4 channels 2 4 GHz 25 TROUBLESHOOTING When failure or error occurs please refer to following solutions to check the device If problems remain please contact your dealer Description Solution When it is turned on Docking Check if the power adapter is Station does not work connected correctly The camera does not light on 1 Press Freeze or Full Quad 2 Check if the camera cable is connected correctly 3 Check if the transmitter is fully charged or turned on No image on Monitor or TV 1 Check if the cable is connected correctly 2 Check if the signal source on Monitor or TV is set correctly 3 For PC please make sure if Driver is already installed Then check if Driver is selected in the Source 4 Check if the channel setting of Docking Station is correct and Transmitter is well connected Stains on the image 1 Clean the camera lens 2 If stains cannot be eliminated please contact your dealer Blurred or shadowed image 1 Itis normal if it appears in the first or signal disturbance minute for warming up 2 Check if P N PAL NTSC setting is correct 3 Turn off on Docking Station or exit the software for resetting 26 NDUSTRIAL CO LTD 6F 70 GUANG FU ROAD SEC 1 SAN CHONG CITY TAIPEI TAIWAN 886 2 29993869 FAX 886 2 29993647 E mail fomedtai ms21 hinet ne
3. 007 IR sensor MICOO8 Remote control 009 Transmitter Charger MICO10 Docking Station power adapter MICO12 Holder PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera TM2 Wireless Transmitter DS539 Wireless Wired Docking Station Installation B Wired Models 1 Model No MN DS520 Standard Accessories 001 Barrier MICOO02 Camera cable MICO003 USB cable MIC004 VGA cable MICOO05 Video cable MICOO06 S Video cable MIC007 IR sensor 008 Remote control MICO10 Docking Station power adapter MICO11 Software amp Driver CD MICO12 Holder PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera 05520 Wired Docking Station Installation jm 8B 3 Adapter 2 Model No MN DS526 With USB Accessories 001 Barrier MICOO2 Camera cable MIC003 USB cable MICOO5 Video cable MICOO06 S Video cable MICOO07 IR sensor 008 Remote control MICO10 Docking Station power adapter MICO11 Software amp Driver CD MICO12 Holder PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera 05526 Wired Docking Station Installation USB to PC i Video Out to TV Monitor 3 S Video to TV Monitor 9 3 Model No MN DS528 With VGA Accessories 001 Barrier
4. Freeze or Full Quad to power on the camera LED lights of the camera will be on The image will be displayed on the screen NOTE Keep pressing Freeze button for 2 seconds the camera will be off LED lights of the camera wand will be off To restart the camera please press Full Quad button If you want to use USB connection please install Software and Driver See Software amp Driver Installation Then open Monitex Soft Image See Software Application We suggest you use the attached disposable plastic sheath barrier for protection during operation IMPORTANT Please turn off on the Docking Station or exit the Software for resetting 5 Docking Station meni CAT DL nma e FREEZE Choc OOOO MOMTEX Full Quad Press the button to capture image in full screen or quadrant 4 images mode Freeze Press FREEZE to capture image and press it again to save the image automatically and return to the live image The number of the stored image will appear on the upper right corner of the monitor screen While using quadrant mode you have to press FREEZE button four times to freeze all 4 images If you press FREEZE button the fifth time all 4 images will be saved temporarily and the live image will return 20 Choice In quadrant mode press Choice button to highlight the frozen image 1 2 3 or 4 The number will turn GREEN This function only wo
5. Monitor T S Video to TV Monitor IE Adapter JE 2 Model No MN DS535 With USB Accessories 001 Barrier MICOO2 Camera cable MIC003 USB cable MICOO5 Video cable MICOO6 S Video cable MICOO07 IR sensor 008 Remote control 009 Transmitter Charger MICO10 Docking Station power adapter MICO11 Software amp Driver CD MICO12 Holder PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera TM2 Wireless Transmitter 05535 Wireless Wired Docking Station Installation USB to PC Video Out to TV Monitor x S Video to TV Monitor J Ls 5 3 Model No MN DS537 With VGA Accessories 001 Barrier MICOO2 Camera cable MICOOA VGA cable MICOO5 Video cable MICOO6 S Video cable MIC007 IR sensor 008 Remote control MICOO09 Transmitter Charger MICO10 Docking Station power adapter MICO12 Holder PX520 P Optional PAL Intraoral camera PX520 N Optional NTSC Intraoral camera Wireless Transmitter 05537 Wireless Wired Docking Station Installation VGA to Monitor Video Out to TV Monitor O S Video to TV Monitor T J uses 3 6 4 Model No MN DS539 With Video S Video Accessories MICOO1 Barrier MICOO2 Camera cable MICOO5 Video cable MICOO6 S Video cable
6. STATION WIRELESS TRANSMITTER AND TV MONITOR SETTINGS Channel and Transmitter settings are only for Wireless Wired Models MN DS530 MN DS535 MN DS537 and MN DS539 Before operating be sure to set Docking Station Transmitter and TV Monitor as stated below 1 Docking Station setting Please see the bottom of docking station P W L PAL NTSC Switch always remains at W N W Channels on Docking Station 1 4 CHANNEL a Please select No 1 to PAL P or NTSC N according to the system used in your country and switch on b No 2 always remains at W setting no matter wireless transmission or wired camera is used For wireless transmission please connect the wireless receiver to the camera socket 13 2 Wireless Receiver Synchronize the channel selection between Transmitter and Receiver For example if you choose channel 1 of Transmitter you also have to select the same channel 1 of Receiver If you choose channel 2 of denies Transmitter you have to select channel 2 of Receiver So do the other cases 3 Wireless Transmitter Channel Display Battery Indicator B HE ent aim Mais a Connect Transmitter to the camera socket and turn on the power Select the channel to be used b Please ensure to use the same channel with Docking Station 4 TV Monitor Please set S Video Video or VGA on TV Monitor according to the signal source from docking station NOTE You can adj
7. Zoom Power Requirement Input Volt 100 240V AC Output Volt 5 0V DC 2 Specifications of Docking Stations DS520 DS526 DS528 and DS529 Dimensions L x W x H 19 3cm x 9 8cm x 5 1cm 278g Image Input Control Wired camera wand Remote control Pedal Docking Station panel or PC Applicable in USB connection Image Output USB VGA Video S Video Optional System PAL NTSC 28 full images 112 quad images Remote Control Function Freeze Memory Delete Full Quad Zoom Power Requirement Input Volt 100 240V AC Output Volt 5 0V DC Full Quad Zoom Freeze Memory Choice 23 3 Specifications of Built in Type Docking Stations DS510 Dimensions L x W x H 11 2cm x 10 8cm x 3 1cm 118g Image Input Control Wired camera wand Remote control Pedal Docking station panel Image Output Video and S Video Power Requirement Input Volt 100 240V AC Output Volt 5 0V DC 4 Specifications of Intraoral Camera PX520 24 5 Specifications of Wireless Transmitter TM2 Dimensions L x W x H 5 4 x 2 8cm x 3 3cm Weight ooo Transmission Channels 4 channels 2 4 GHz Frequency Rechargeable Battery 1 built in 3 7V 500mAh Li ion battery which can supply 30 minutes of continuous imaging per full charge Charger Input Volt 100 240V AC Output Volt 4 5 9V DC Recharging Time Battery Power Indicator LED Full charge red Insufficient yellow 6 Specifications of Wireless Receiver
8. account Click Search to show all saved accounts Highlight the account and then click Enter into Monitex image NOTE You may use the Edit or Delete to edit saved data or delete data When click Enter into Monitex image press Capture and Still Image Capture window will pop up gt OL s Qs pa H F ama Dogs sor IMPORTANT For the first use of this software please click Source to select Driver Bose view 17 To take pictures press Freeze button on the camera to freeze the image Then click the Capture button on Still Image Capture window to save it and press Freeze to go back to the live image Or use Freeze button to save images temporarily in Docking Station memory Then use the remote control Previous Image Next Image to recall the images and press Capture button to save one by one hadie X nana GO Campa Qh omma To have a full screen of a saved image please highlight the image and click Compare 18 To compare saved images please click Select Cancel Highlight the images and then click Compare 2 4 1mages 19 OPERATION Please properly connect and install MoniCam See Various Models and Installation Ensure the settings are complete See Docking Station Wireless Transmitter and TV Monitor Settings Turn on Docking Station and Wireless Transmitter Press
9. MONITEX Intraoral Camera User Manual TABLE OF CONTENTS PRE RAC orice M E l DS SINI Rie l PRECAUTIONS SI CAUTIONS deer l WORKING ENVIRONMENT ausarai 1 OPHONADACCESSORIBSU 2 CONNECTIONS OF DOCKING STATION 3 VARIOUS MODELS amp INSTALLATIONS 4 DOCKING STATION AND TV MONITOR SETTINGS 13 SOFTWARE amp DRIVER INSTALLATION 15 OPRERATION 222222222222 22 222221212 2 9 1 4 9 00 0 Udo 20 SPECIHIGA IONS z uuu lli 23 TROUBLESHOOTING 26 PREFACE 1 Prior to using MoniCAM intraoral camera please read this User Manual carefully and keep it for future reference 2 If any damage or problem occurs do not continue to use or try to repair by yourself Please contact your dealer 3 Defects ofthe products which caused by natural disasters such as bad weather or improper temperature and by faulty materials will be checked Explanations will be given accordingly 4 The specifications are subject to change and revision without prior notice DISCLAIMER 1 We shall not assume any responsibility if any malfunction or damage caused by improper operation removal modification or maintenance 2 We shall not assume any responsibility if any malfunction or damage caused by operation in improper ambient environment 3 We shall not ass
10. adrant to zoom specific image from the quadrant Press the button again to return to normal size Delete Single Image This function will delete the SINGLE image that 1s displayed on the screen All Clear This will delete all stored images When it is pressed you will be asked ARE YOU SURE To proceed press the All Clear button again and this will delete all stored images Freeze Press this button to capture the image shown on Monitor Press it again to save this image and the live image will return LIE Full Quad Press this button to capture the image in full screen or quadrant 4 images Previous Image and Next Image w Allows you to scroll the stored images IMPORTANT 1 Before using Remote Control please take out the plastic insulating pad from the button battery 2 One button battery is used in Remote Control Please replace it when the battery is low 22 SPECIFICATIONS 1 Specifications of Docking Stations 05530 05535 05537 and 05539 Dimensions L x W x H 19 3cm x 9 8cm x 5 1cm 278g Image Input Control Wireless Wired camera wand Remote control Pedal Docking Station panel or PC Applicable in USB connection Image Output USB VGA Video S Video Optional Function Full Quad Zoom Freeze Memory Choice System PAL NTSC Wireless Channel 4 channels Wireless Wired 28 full images 112 quad images Remote Control Function Freeze Memory Delete Full Quad
11. rks in quadrant mode Zoom In quadrant mode press Choice button to select frozen images when the number is highlighted in GREEN Press Zoom and the selected image will be zoomed in Press Zoom again to return to the normal size This function only works in quadrant mode 6 Camera PX520 Full Quad Choose a full screen mode or a quadrant 4 1mages mode ma n sm Freeze Press Freeze button to capture image Press it again to save automatically and return to the live image While using quadrant mode you have to press Freeze button four times to freeze all 4 images If you press it the fifth time all 4 images will be saved and the live image will return 7 Wireless Transmitter Battery Indicator Charger On Off i 1 gt EGER ip b iHa i Hi pw wass Channel Display Channel Selection a The transmitter has a Battery Indicator When battery capacity is sufficient its light is green When battery capacity is insufficient its light is yellow and you may recharge the battery b Select channels from 1 to 4 The power switch 15 on the side of Transmitter IMPORTANT Before use please remember to set Docking Station and Transmitter TM2 on the same channel 1 2 3 or 4 21 8 Remote Control Delete Press shaded quadrant to delete the specific image from the quadrant Press Freeze to re capture image for the quadrant Zoom Press shaded qu
12. t http www monitex com tw
13. ter MIC011 Software amp Driver CD k i PE m ecd em i MICO12 Holder TM2 Wireless Transmitter PX520 P N Optional Intraoral Camera ave DS520 DS526 DS528 DS529 DS530 DS535 DS537 TM3 Wireless Receiver D S510 Docking Station DS539 Docking Station Built in Type 2 CONNECTION OF DOCKING STATION Camera socket VARIOUS MODELS amp INSTALLATIONS Please check the proper MoniCAM model for connection and installation A Wireless Wired Models IMPORTANT If you do not like to use wireless transmitter camera cable is also available Prior to using the wireless transmitter please charge for two hours When the charging is completed please remove the charger from the transmitter Please switch on the transmitter and press FREEZE button to start your operation LED lights will be on instantly when FREEZE button is pressed 1 Model No MN DS530 Standard Accessories 001 Barrier MICOO9 Transmitter Charger 002 Camera cable MICO10 Docking Station power adapter USB cable MICO11 Software amp Driver CD MIC004 VGA cable MICO12 Holder MICOO5 Video cable PX520 P Optional PAL Intraoral camera MICOO6 S Video cable PX520 N Optional NTSC Intraoral camera 007 IR sensor TM2 Wireless Transmitter MICOO8 Remote control DS530 Wireless Wired Docking Station Installation USB to PC VGA to Monitor Video Out to TV
14. ume any responsibility if any malfunction or damage caused by force majeure PRECAUTIONS amp CAUTIONS 1 The intraoral camera should not be autoclaved Please clean it with mild detergents or disinfectants 2 Please use the attached disposable plastic barrier sheath for protection when operating 3 Do not touch the connectors with conductive material such as metal or with moisture to avoid short circuit or possible damages 4 Do not disassemble the device by yourself which would cause unexpected damages Do not press the device or the accessories such as cables to avoid any damage 6 If this camera will not be used for some time please disconnect the power cord WORKING ENVIRONMENT 1 Please install this device in the dry place Do not expose it to sunlight directly or install it in a dusty or humid place or at the improper temperature too hot or too cold 2 Operating environment Ambient temperature 20 50 Relative Humidity 30 90 3 Transportation and storage environment Ambient temperature 20 60 C Relative Humidity 10 90 OPTIONAL ACCESSORIES 2 2 4 J MICO001 Barrier MICO002 Camera cable MICO003 USB cable MICO004 VGA cable a gt om LU er E Toe c T MIC005 Video cable MIC006 S Video cable MICO007 IR sensor MIC008 Remote control MIC009 Transmitter Charger MICO1I0 Docking station adap
15. ust the brightness contrast or color of TV Monitor to have better effects on images 14 SOFTWARE amp DRIVER INSTALLATION Software and Driver are required ONLY for USB connection T erm EL uE 7 m 1 Driver Installation D When the connections and settings are complete please connect USB cable to PC Win XP WIN 2000 will automatically detect the new EMBED c device MESA pee cae bimi Q Please insert the attached CD to CD ROM PC will search for Driver Click Next Step to finish Driver Installation 2 Software Installation Monitex Soft Image When Driver Installation is complete please open the CD file and double click the Setup PC will start the software installation a Tammi inam Tema mnaman repen eset Pte ay NOTE During the installation please click Setup button to complete the process 15 3 Software Application Power on Docking Station and the camera Press Freeze or Full Quad button LED lights of the camera will be on From the PC Start menu please click Monitex Soft Image to enter Monitex login window For the first time user please enter the new account data and click Add data to establish a new account Then click Enter into Monitex image Enter the saved account number and click Search to find out the
Download Pdf Manuals
Related Search
Related Contents
成 レールカッター 取扱説明書 Samsung GT-S5780 Инструкция по использованию Nah-Projektionssystem SCP725 Copyright © All rights reserved.
Failed to retrieve file