Home
USER MANUAL
Contents
1. You can also use the supplied touch pen to select and confirm you selection Lock Press this key to lock the keypad and press again to unlock by entering the unlock password with the number pad To set the password please see Set Password at page 17 Joystick Movement Camera Control Tilt up Move the camera up Tilt down Move the camera down Tilt left Move the camera left Tilt right Move the camera right Turn clockwise Zoom In Turn counter clockwise Zoom Out General NOTE The actual operation varies depending on the device you switch to e Menu Press this key to show the main menu of the connected device O and press again to go to the upper level of the menu list or exit NS N the menu Dr e Navigation 5 A Press lt D to move the cursor or highlight up down left right To enter or confirm your L selection press amp 7 Enter Press to change the setting of the menu O O e Number Pad 0 9 Used to enter the camera ID DVR ID channel number password etc 1 5 O To Confirm your key in ESC Clear your key in O O 0 tO QO O g Camera Control Press Q device selection key to switch to the speed dome camera mode and you can control the following function keys and perform certain functions by some certain keystroke combinations NOTE You can also use the camera control keys FOCUS QA D TRACK and STOP when the DVR device
2. Figure 3 Solder side of this product s NORMALLY is triggered by a momentary short supplied 9 pin D Sub connector OPEN in a normally open N O circuit 5 N C When N C is connected an alarm NORMALLY is triggered by a momentary break CLOSED inanormally closed N C circuit Table 2 PIN configuration c RS485 Port DVR P T Z Two RS485 ports used to connect to a speed dome camera or DVR e Port Connection amp System Mode Selection Device Connection Method Port Mode A DVR and a DVR DVR Mode1 camera Camera P T Z A DVR DVR Mode1 Two DVRs or a parallel DVR Mode more DVR Mode2 A camera PTZ Both Mode1 and Mode2 are OK DVR amp P T Z Mode2 Two cameras Parallel DVR Mode2 or more Parallel DVR Both Mode1 and Mode2 are OK Table 3 RS485 port connection and system mode selection d LAN Connect to the local area network LAN or Internet through a network cable with RJ 45 connectors This port can be used for firmware upgrade and extend the scalability of this product e Power Connector DC 12V Connect to the supplied adapter To select the mode press FUNT key on this product and go to System gt Mode For details please see Mode at page 17 For parallel connection details please see Parallel Connection With Two Or More Cameras at page 6 and Parallel Connection With Two Or More DVRs at page 8 Ans 3 Speed Dome Camera Connection There are only two
3. Mode Selection Live Mode Playback Mode AUDIO OFF AUDIO OFF AUDIO 1 L AUDIO 1 P AUDIO 2 L AUDIO 2 P AUDIO 3 L AUDIO 3 P AUDIO 4 L AUDIO 4 P Table 4 Audio channel switch 14 Q O LAST 1 gt NEXT e Playback Keys EA Press to open the search list in which you can find the C recorded events and play the corresponding video clip QZ YW J 4 i gt gt Select one event from this list by using the navigation keys and press to play the video clip gt Press to play the selected video clip gt gt Press to fast forward the video clip from 4X to 32X Press to fast rewind the video clip from 4X to 32X l Press to pause the video play MW Press to stop the video play and go back to the live view e Display Mode Selection Keys Press to display a single channel Press to display the 4 cut view Press to display the 8 cut view Press to display the 9 cut view Press to display the 16 cut view C EB BH RJ a Press to display each channel one by one i Shortcut Keys wmm Press and hold ey and press FUN 1 SET SEQ GOTO and EE respectively to quickly perform different functions as follows Key Combination Description C This keystroke combination will show the camera S gt OW MY and FUN 1 ID display on the monitor if the ID is hided This keystroke combination will clear the camera sWe and SET Clear ID ID
4. RS485 ports DVR P T Z for camera connection For the normal camera connection please see Normal Camera Connection at page 5 For the parallel connection with two or more cameras please see Parallel Connection With Two Or More Cameras at page 6 NOTE You need a RJ11 line to connect this product and a speed dome camera Different RJ11 connector may have different line layout so the connection might be different If you cannot control the camera after connection please reverse the RJ11 line connection with the camera a Normal Camera Connection Step1 Before connecting this product to your speed RJ 4 4 Line RED RS485 dome camera finish the camera connection and setup first as described in your camera s user in manual lt lt E Step2 Get a RJ11 line with the proper length for your G A connection GREEN 485 B Step3 Remove one end of the insulating coating of the RJ11 line to reveal four wires Find the RS485 A and the RS485 B wires and remove the Figure 4 RJ11 Line insulating coating to reveal the naked wires for further connection For example in Figure 4 the RS485 A wire is the red one and the RS485 B wire is the green one NOTE RJ11 line is not supplied in the sales package Step4 Find the RS485 A and RS485 B wires from your speed dome camera Figure 5 For details please check your camera s user manual Step 5 Twist the red and green wires of the RJ
5. aiii 3 ale JP OMG UO HIO Fl oocken E a a oan osse enfe tton foo c ten tea ai cnt Ina n ELEC 3 C E5495 Port A A dastdetiun RE tea 4 Port Connection amp System Mode SelectiON cccccoocnnccncccccconccnnncononononnncnnoonnnnnnonnonnnnnononnnnnnnnnnnononcnnnnos 4 de LAN dt ld eo 4 e Power Connector DG 12V cit ocio ite e Lc UU alae 4 2 opeed Dome Camera CAM Na 5 a Normal Gamera Gonrneclob a5 e o dee qu 5 b Parallel Connection With Two Or More CamMeraS c coccnccnoccnccoccncccccnnnoncnononnnononnnononnnonnnnnonnnnnonnnrnnnnrnnonarennnnnens 6 4 TVR AG ORMOCUOMN e ed 7 a Single DVR COMO CI OM srta tia olas 7 b Parallel Connection With Two Or More DVRS cccccccseeeeeeceeeeeeceeeeeeeseaseeeeseaeeeesseuseeessaueeeeseeeeesseeeeeesanes 8 PARTSAND KEYS cui 10 T ASA uolo a 10 EGDEDIIS Kc ia 10 FUNCION OF Each CY RN e E o M 11 a Device Selecliobii desinis de adu A MM I Cid M LM LEE MI d E UE 11 Dj DEVICE CORTON napa E TT 12 6 Gontroller COMNOUNAUOM NM ERE m e 12 Gye LOGI quM o yen 12 COMM Io A A MUERE EE 12 DEEST T E Nd 12 EE E AE Mo o PE CO 12 INIA id 13 EI R rm 13 BEIC Padian mmm 13 ad Camera COn tol n R a a 13 Me DYR GOTO Ncc 14 ET Audio Channel Selection da 14 Ei Playback A T LE 15 Display Mode Selection Keys cccccccccssssscceeceaees
6. information saved in the camera and restore to the default setting 00 This keystroke combination will hide the camera ID CJ display on the monitor To show the ID again press SW and SEQ Hide ID CJ SWS and FUN 1 Show Firmware This keystroke combination will show the current S nJS WS and GOTO Version firmware version for your reference This keystroke combination enables the reset of SWE and EN Reset Default this product to the factory settings Then it will prompt you to shut down and power up again Table 5 Shortcut Keys 15 PROGRAMMING Press FUN 1 key to configure the controller system connected camera s and connected DVR s You can use the following keys or the supplied touch pen to make your settings Key Nagivation Number Pad Menu 1 Menu Tree Function Wi JJ to enter or confirm Number 1 9 to key in the digits such as the host ID D to move between each selection your selection 4 to confirm your key in ESC to clear your key in A to go to the previous menu level Table 6 Keys for programming 16 2 Menu List a System In this menu list you can set the password to unlock this product System set the host ID turn on off the buzzer select the mode and set the CAM network DVR Exit Menu Figure 11 System e Set Password Set the password for the keylock function When the keypad is locked press Oal and enter the password you s
7. is switched to sias h NOTE SET SEQ GOTO FOCUS a a TRACK STOP DVR Control DVR tt Press with M to enable the shortcut key function for clearing ID Enable the cruising function of the speed dome camera if you have set any sequence group For details of how to set a sequence group please refer to your camera s user manual Press and enter the sequence group you want to see from 1 to 8 by using the number pad For details of the number pad please see Number Pad at page 13 Press and enter the preset point you want to see from 1 to 255 by using the number pad For details of the number pad please see Number Pad at page 13 Adjust the focal length Zoom out in Press to start tracking and press again to quit and return to the live view Press to stop the PTZ auto tracking or cruising M SEQ f j Focus Press _ device selection key to switch to the DVR mode and you can control the following functions You can also use the camera control keys FOCUS Q A TRACK and STOP when the mE l DVR device is switched to e Audio Channel Selection Keys Press NEXT or LAST to choose the next previous audio channel to hear the live sound in the live mode or the recorded sound in the playback mode For example if the connected DVR supports 4 audio channels
8. x 1 Adapter x 1 User Manual x 1 CONNECTION AND SETUP 1 General Connection 16CH DVR HTA p Eds 0Os 00O eO ee ee es es T E E 8 o l Y i Y uy y PL eee WY Il MEM ULM m x U 3X 3X 22X pe m PTZ camera PTZ camera PTZ camera a SX MEC MEN E niim alarm device l I DC12V Adapter s speaker BH 9 2 L I O O o o Last 1 nexr GOD OO g P4 o lt o NE ms 0000 0000 QOO 0000 Figure 1 Example of keyboard controller connection connect up to 64 devices 2 Connectors on Rear Panel LAN AUDIO EXTERNAL I O DVR P T Z Figure 2 Connectors on the rear side a Audio Out AUDIO Audio out connector used to connect to an audio device such as a speaker b External I O Port EXTERNAL I O RS 232 port used to connect to an external alarm device with the supplied 9 pin D Sub connector e PIN Configuration Only PIN 1 3 and 5 are functional Connect to PIN 1 amp 3 or PIN 1 amp 5 depending on your situation PIN FUNCTION DESCRIPTION 1 COM COM is used with N O or N C for COMMON the N O or N C circuit to take effects For the N O or N C connection and the alarm triggered criteria see the description below COM N O N C 3 N O When N O is connected an alarm
9. 11 line to the corresponding wires of your camera Figure 5 Example of Take Figure 4 amp 5 as an example the connection RS485 A and RS485 B wires will be as follows RJ11 Line Camera Red wire RS485 A Brown wire Green wire RS485 B Orange wire Step6 To protect the naked wires use the insulation tape to cover on the twisted wires Step7 Connect the RJ11 connector to the RS485 port DVR and or P T Z on the rear side of this product depending on your connection needs For details please see Table 3 RS485 port connection and system mode selection at page 4 for details Step8 Press FUN1 key on this product and go to System and CAM to make related settings e System See System at page 17 for details Mode Select Mode1 or Mode2 depending on your connection needs For details please see Table 3 RS485 port connection and system mode selection at page 4 for details Net Setup Check if this product is under the same domain as the connected speed dome camera e CAM See CAM at page 18 for details Baud Rate Check and select the baud rate the same as the connected speed dome camera is used Protocol Choose the proper camera protocol depending on the camera type AVP321 AVP311 PELCO PELCO D CAM ID Assign a unique ID This ID is important for this product to identity the camera you want to control if two or more speed dome cameras are connected b Parallel Con
10. 195Z USER MANUAL CONTROL DEVICE WITH FULL FUNCTIONALITY Thank you for choosing this keyboard controller Before attempting to connect or operate this product please read the instructions thoroughly and save this manual for future reference AVP101_V0 9 IMPORTANT SAFEGURARD CAUTION CAUTION RISK OF ELECTRIC SHOCK To reduce the risk of electric shock do not expose this apparatus to rain or moisture Only operate this apparatus from the type of power source indicated on the label The company shall not be liable for any damages arising out of any improper use even if we have been advised of the possibility of such damages AN A A C The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons This exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance ROHS Announcement All lead free products offered by the company comply with the requirements of the European law on the Restriction of Hazardous Substances RoHS directive which means our manufacture processes and products are strictly lead free and without the hazardous subst
11. System See System at page 17 for details Mode Select Mode1 Net Setup Check if this product is under the same domain as the DVR e DVR See DVR at page 19 for details Baud Rate Check and select the baud rate the same as the DVR is used Protocol Choose the proper DVR protocol depending on the DVR type DVR 16 16CH DVR 8 8CH DVR 4 ACH DVR ID Assign a unique ID This ID is important for this product to identity the DVR you want to control b Parallel Connection With Two Or More DVRs Step1 Step2 Step3 Before connecting this product to your DVR finish your DVR connection and setup first as described in your DVR s user manual Get enough RJ11 lines with the proper length for your connection If you want to connect two DVRs three RJ11 lines will be needed if you want to connect three DVRs four RJ11 lines will be needed and etc The following description will take two DVR connection as an example Remove one end of the insulating coating of the RJ11 line to find the RS485 A and the RS485 B wires and remove the insulating coating to reveal the naked wires for further connection For example in Figure 6 the RS485 A wire is the red one and the RS485 B wire is the green one NOTE The RJ11 line is not supplied in the sales package Step4 Stepb otep6 otep Steps Step9 Solder the red and green wires of the RJ11 line to the corresponding pins of the D Sub connector su
12. ances cited in the directive The crossed out wheeled bin mark symbolizes that within the European Union the product must be collected separately at the product end of life This applies to your product and any peripherals marked with this symbol Do not dispose of these products as unsorted municipal waste CE Mark This apparatus is manufactured to comply with the radio interference We reserve the right to make improvements to the documentation software and firmware of its products without notice In order to provide users with better operation of this product information in this manual is intended to be accurate and reliable However we assume no responsibility for its use nor for any infringements of rights of third parties whom may result from its use Any changes of this manual are subject to the actual product without further notification Firmware Version 1 041 E aud aad TABLE OF CONTENTS INTRODUC ON rusarii oo 1 Te OVVIO v est o A E E ET 1 VNEE I II P 1 SWE s eije ep fet M T O TEES 1 Me packages OMOCM nisi ode deett roo ETE ta etant cU den ttes a eed iieri lich cc TE rE Pede 2 CONNECTION AND SETUP una 3 EE Falls COMMO CI OM PA UU E m 3 2 Golinectors on Rear PAN li tees teile era atero A Sede eevee dee eae ne SUN ele 3 ay Audio OUR AU DIO cicistinc octies uoce a ea 3 b External VO Port EXTEIRINAE TIG isc itat eda tu eet Da me pal be be eua
13. cceeeeeeeeeceeecaeseseceesseueseeeeeesseeseeeeessueueeeessausaeaeeees 15 e SS note IE SS dll illo 15 gisiSIC Asl cm pci uadoacanaant sanscedeauinindacenecasie 16 EM WOT INC A E P pen 16 PB MENU Said 17 AA 17 El SUIS WO a cas 17 OSI c cer 17 Lee UZ OM AA A on E a A A a 17 E A Gloss E A Boal Dekh aed ae ln aa n id alee 17 CE UNV ee CUNO TUO RE NU nn EN 18 RA 18 MES Mii ad 18 El Baud Rate UT a a a 19 E A T T r S S E E 19 PEA E A M P eee 19 A A cee ae edes ous hin dh aanietdeadees bin ca eiee H 19 A Mr a E 19 PS e a a r EE 20 aod it ana 20 BK Cp EE EMEN TN 20 BERI I Um TC 20 o NM oM UM EC e e 8 20 7 7 LIST OF TABLES Table 1 Keyboard controller specificatiONS oooccocccocncccncocnnonononocanonanconononnnnononcnnaronaronaronoss 1 Table ih Keoniletr iepem tt EM 4 Table 3 RS485 port connection and system mode selectiON ooccooncconcocncccncccnnnononcnnanonanonos 4 Table 4 Audio channel switch ccccccceccececeeceeceeeseeceeeeeecaeeseeseeeaeeseesaeeseetaseseesaeeeeesensueeseeess 14 lso ea LL E TE 15 Table 6 Keys Tor programimibig sisi 16 Table 7 RS 485 port connection and system mode selection seseeeesessss 18 Figure 1 Example of keyboard controller connection connect up to 64 devices 3 Figure 2 Connmnecters on TNE Fear SIGO iis ace her hataiu etel ae aed
14. e tod nud dl Ru Ead 3 Figure 3 Solder side of this product s supplied 9 pin D Sub connector 4 meis SUE cc H RHET 5 Figure 5 Example of RS485 A and RS485 B wires eese nennen 5 A ITEN E C Geeeses T Figure 7 Solder side of the DVR s supplied D Sub connector eeseeeeeeeeeeeeeese T Figure 8 Example of Parallel Connection with Two DVRS occcocncccncccncocococococonoconanonanonanonanonoos 8 Figure 9 Controller Keypad Layout cccccccseccescceeecseeceeeceecceeeceeseuecegesaeesaeesaeeseeeseessensaeesaes 10 Figure TO LED Display S Touch Panels asiatico delos alot Dias eR eio T 10 Foure Mel IR NN S T TU TT 17 Figure T2 ASMA SSelllliQ s d d cix Aaah ocu temo hee ea lo eee dee he ch 17 FIS To reru BE ELE ai 17 Foure T4 EUZZC D o OC PR adsit o 17 meis oxueoc T HA ee 17 Figure 16 Example IP Address Sel Oricon cid eee 18 AO IN PER 18 FOUE rome GAVE UR a mn Serie ers TUS 19 FIgure 19 CAM ProlOCO lssi dde 19 FIGURE 20 CAMA A 19 FOUG 21 REU Ee MERE 19 FOWO yd Bi e o 19 FIgure z9 DYR Balla ale e ed ed 20 PIQUIC 24 DVR ProtOCOl RR 20 mios cc Zo DYR A teats 20 INTRODUCTION 1 Overview This product is designed for use with all our speed dome cameras DVRs and the door access control syste
15. er length to your connection Remove one end of the insulating coating of the RJ11 line to find the RS485 A and the RS485 B wires and remove the insulating coating to reveal the naked wires for further connection For example in Figure 6 the RS485 A wire is the red one and the RS485 B wire is the green one The RJ11 line is not supplied in the sales package Solder the red and blue wires of the RJ11 line to the corresponding pins of the D Sub connector supplied with the connected DVR Figure 7 RJ11 Line DVR Sub Connector Red wire 15PIN Connector PIN11 RS485 A 25PIN Connector PIN12 Green wire 15PIN Connector PIN10 RS485 B 25PIN Connector PIN24 Table 4 RJ11 line to DVR Connection lt lt RJ11 Line RED RS485 A GREEN RS485 E m LR ca wma RJ11 Connector Figure 6 RJ 11 Line oolder Side of 15 pin D Sub connector RS485 A PIN11 RS485 B PIN10 8 T 6 5 4 3 2 1 Oo0O000000 0 O O O OOOO 15 14 13 12 11 10 9 16 17 Solder Side of 25 pin D Sub connector RS485 A PIN12 RS485 B PIN24 Figure 7 Solder side of the DVR s supplied D Sub connector To protect the naked wires use the insulation tape to cover on the twisted wires Insert the connector to the DVR s external I O port Connect the RJ11 connector to the Port1 on the rear panel of this product Press FUN1 key on the keyboard and go to System and DVR to make related settings e
16. et here to unlock the keypad Select Set Password Enter the old password first 4 digits and enter the new password The default password is 0000 gt Set Password Old Password New Password Confirm Confirm Host ID 00 Buzzer On p p Mode Model Save OK ZN ats t 5 Figure 12 Password Setting y e Host ID Set the ID of this product when the connected device is also Set Password Host ID 00 Buzzer On Mode Model connected to other device s The connected device needs this ID to identify this product Use the number pad to assign and enter an ID for this product and press Hi confirm The default setting is 00 OSHO e Buzzer Select to enable On or disable Off the buzzer of this product Set Password Host 1D 00 gt Buzzer On The default setting is ON Mode Model by pressing Figure 14 Buzzer o J and select Mode or Mode2 depending on the set Password Host TDr00 devices you re connected For details please see Table 6 at Bovpapssn page 18 gt Mode Model The default setting is Mode Figure 15 Mode 17 Device Connection Method Port Mode A DVR and a DVR DVR Mode camera Camera P T Z A DVR DVR Mode1 Two DVRs or mote parallel DVR Mode Srs DVR Mode2 P T Z Both Mode1 and Mode2 are OK E DVR amp P T Z Mode2 wo cameras ar more parallel DVR Mode2 parallel DVR Both Mode1 and Mode2 are OK Table 7 RS 485 port connecti
17. he default setting is 2400 Return NOTE The setting here must be the same as the setting in the DVR system configuration for the control of the Figure 23 DVR Baud Rate DVR to work properly e Protocol Select the appropriate protocol for the connected DVR The options are DVR 16 DVR 8 DVR 4 16CH 8CH 4CH pene Rae gt Protocol DVR 16 The default setting is DVR 16 DVR ID 00 Return Figure 24 DVR Protocol e DVRID Set the ID of the connected DVR when this product is Baud Rate 2400 Protocol DVR 16 identify each connected DVR gt DVR ID 00 connected to two or more DVRs This product needs this ID to Return Use the number pad to assign and enter an ID for the camera and press a to confirm The default setting is 00 Ao e Return Select to go to the previous menu level d Exit Menu Quit the programming and return to the standby mode 20
18. m It can serve as a control console to manage your surveillance system and is able to control up to 64 devices with the convenient 3D joystick and functional keypad design Accurate control of the pan tilt zoom movement for a speed dome camera becomes easy and you can operate other devices via this product conveniently Features Control up to 64 devices through one keyboard controller Devices such as the PTZ camera DVR and door access control etc User friendly button placement amp touch LCD panel 128 64 pixels for easy operation Network upgrade available for future scalability Support our own protocol and PELCO D Password protection to prevent unauthorized users Built in microphone for broadcast function Specifications Keyboard Controller Device Control PTZ camera DVR and door access control etc Remote Control RS 485 Protocols Our own protocol and PELCO D Baud Rate 2400 115200 LCD Display 128 64 pixels Ethernet Port 10 100 Base T Serial Port 9 Pin D Sub Input Voltage DC12V Power Consumption lt 2W Operating Temperature 0 C 40 C Operating Humidity lt 95 Dimension 380 W mm x 180 H mm x 95 D mm The specifications are subject to change without notice Table 1 Keyboard controller specifications 4 Package Content Please make sure you have the following items in your sales package 2 i LH Keyboard Controller x 1 Touch Pen x 1 9 pin D Sub Connector and its accessories
19. nection With Two Or More Cameras Step1 Before connecting this product to two or more speed dome cameras finish the camera connection and setup first as described in your camera s user manual Step2 Get a RJ11 line with the proper length for your connection Step3 Remove one end of the insulating coating of the RJ11 line to find the RS485 A and the RS485 B wires and remove the insulating coating to reveal the naked wires for further connection For example in Figure 4 the RS485 A wire is the red one and the RS485 B wire is the green one NOTE RJ11 line is not supplied in the sales package Step4 Find the RS485 A and RS485 B wires Figure 5 from all your speed dome cameras For details please check your camera s user manual Step 5 Twist the red wire of the RJ11 line and the RS485 A wires of all the cameras together Then twist the green wire of the RJ11 line and the RS485 B wires of all the cameras together Step6 To protect the naked wires use the insulation tape to cover on the twisted wires Step7 Connect the RJ11 connector to the RS485 port DVR or P T Z on the rear side of this product depending on your connection needs For details please see Table 3 RS485 port connection and system mode selection at page 4 for details Step8 Press FUN1 key on this product and go to System and CAM to make related settings e System See System at page 17 for details Mode Select Mode1 or Mode2 de
20. on and system mode selection e Net Setup Set the IP address subnet mask and gateway of this product Move to the item you want to set and press to enter the selection and make settings The default settings are as follows IP Address 192 168 1 90 Subnet Mask 255 255 255 000 Gateway 192 168 1 1 Buzzer On gt Set IP Address Set IP Address Mode Model Set Subnet Mask gt 192 168 000 090 gt Net Setup Set Gateway Return Return Return Figure 16 Example IP Address Setting e Return Select to go to the previous menu level b CAM When this product is connected to a speed dome camera go to u ystem this menu list to set the baud rate protocol and ID of the gt CAM connected camera for the camera control to take effect DVR Each camera must be assigned a unique ID and the baud rate Exit Menu and protocol settings must be chosen correctly for the camera control to work properly For details please check the Figure 17 CAM description below For parallel connection details please see Parallel Connection With Two Or More Cameras at page 6 and Parallel Connection With Two Or More DVRs at page 8 18 e Baud Rate Select the baud rate for the connected camera by pressing gt Baud Rate 2400 Protocol AVP321 iJ The options are 2400 4800 9600 19200 38400 CAM ID 00 5 600 Return The default setting is 2400 Note The setting here must be the same as
21. pad layout of this product from which you can briefly check the functions of this product For details of each key function please see Function of Each Key at page 11 LAST 1 next Q 44 gt gt Q gt m 000 Focus QQ OO TRACK STOP e Q o O N Figure 9 Controller Keypad Layout 2 LCD Display Device LED Indicate which device this product is controlling right T Fg now WwW X The icons from left to right represent the PTZ camera door access system lighting system microphone and CAM ID 00 DVR respectively DVR 1D 00 To switch between each device please see Device Selection at page 11 for details Figure 10 LED Display amp Touch Panel 10 Touch Panel In the standby mode it shows the latest camera ID and DVR ID this product controlled When you press any key the command sending status will be shown below the ID information When the key FUNT is pressed for programming you can move between each option amp confirm your selection by using the navigation keys see Navigation at page 13 amp the number pad see Number Pad at page 13 NOTE You can also use the supplied touch pen to select and confirm you selection To switch between the connected cameras or DVRs A7 DVR press SW or 57 first and the corresponding LED will be lit P
22. pending on your connection needs For details please see Table 3 RS485 port connection and system mode selection at page 4 for details Net Setup Check if this product is under the same domain as the connected speed dome camera e CAM See CAM at page 18 for details Baud Rate Check and select the baud rate the same as the connected speed dome camera is used Protocol Choose the proper camera protocol depending on the camera type AVP321 AVP311 PELCO PELCO D CAM ID Assign a unique ID This ID is important for this product to identity the camera you want to control if two or more speed dome cameras are connected 4 DVR Connection There is only one RS 485 port available for DVR connection Port1 For the single DVR connection please see Single DVR Connection at page 7 For the parallel connection with two or more DVRs please see Parallel Connection With Two Or More DVRs at page 8 NOTE You need a RJ11 line to connect this product and a DVR Different RJ11 connector may have different line layout so the connection might be different If you cannot control the DVR after connection please reverse the RJ11 line connection with the DVR a Single DVR Connection Step1 Step2 Step3 NOTE Step4 Stepb Step6 Step7 Steps Before connecting this product to your DVR finish your DVR connection and setup first as described in your DVR s user manual Get a RJ11 line with the prop
23. pplied with the connected DVR Figure 7 Twist the red wire of the RJ11 line and the RS485 A wires of the two DVRs together Then twist the green wire of the RJ11 line and the RS485 B wires of the two DVRs together AUDIO EXTERNAL O DVR P T Z LAN RJ11 Jack RS485 A Red RS485 B Green 25 pin D Sub connector 15 pin D Sub connector PIN12 RS485 A PIN11 RS485 A PIN24 RS485 B PIN10 RS485 B Figure 8 Example of Parallel Connection with Two DVRs To protect the naked wires use the insulation tape to cover on the twisted wires Insert the D Sub connector to the DVR s external I O port Connect the RJ11 connector to the port DVR on the rear panel of this product Press FUN1 key on the keyboard and go to System and DVR to make related settings e System See System at page 17 for details Mode Select Mode Net Setup Check if this product is under the same domain as the DVR e DVR See DVR at page 19 for details Baud Rate Check and select the baud rate the same as the DVR is used Protocol Choose the proper DVR protocol depending on the DVR type DVR 16 16CH DVR 8 8CH DVR 4 ACH DVR ID Assign a unique ID This ID is important for this product to identity the DVR you want to control PARTS AND KEYS This chapter describes the keypad layout and the function or usage of each key and the combination keys 1 Keypad Layout Figure 9 shows the key
24. ress and the selection icon will be shown on the LCD screen Move the selection to CAM ID or DVR ID by using the a navigation keys J and enter the ID number of the camera or DVR you want to control by using the number pad NOTE When a speed dome camera or a DVR is connected press FUN1 to program the connected device including the ID setting Please see the chapter PROGRAMMING at page 16 for details 3 Function of Each Key a Device Selection l Choose from the device selection keys s based on the connected device The keys on the right hand side represent the devices this product can control speed dome camera WS door access control t lighting system nen 0 DVR microphone 50 and DVR l _ Je iy e b Device Control C d f This key set is designed to use with the control of the door access O O e Q 0 OFF 0ON LI lighting system Y and microphone 36 Press ON OFF to turn the device on off Lighting system control and microphone control will be ready soon Controller Configuration FUN1 Press to configure the controller system and the connected camera s and DVR s For configuration details please see the chapter PROGRAMMING at FUN 1 page 16 Use the nagivation keys see Navigation at page 13 amp number pad see Number Pad at page 13 to select modify or confirm the setting you want NOTE
25. the setting F gure 18 CAM Baud Rate in the connected speed dome camera for the control of the camera to work properly e Protocol Select the appropriate protocol for the connected speed dome camera The options are AVP321 AVP311 PELCO acid gt Protocol AVP321 PELCO D CAM ID 00 The default setting is AVP321 Return Figure 19 CAM Protocol e CAM ID Set the ID of the connected speed dome camera when this Baud Rate 2400 Protocol AVP321 needs this ID to identify each connected camera gt CAM ID 00 product is connected to two or more cameras This product Return Use the number pad to assign and enter an ID for the camera and press Hi confirm The default setting is 00 Figure 20 CAM ID e Return Select to go to the previous menu level Buzzer On Mode Model Net Setup gt Return Figure 21 Return c DVR When this product is connected to a DVR go to this menu list to oystem set the baud rate protocol and ID of the connected DVR for the 2 DVR control to take effect gt DVR Each DVR must be assigned a unique ID and the baud rate and Exit Menu protocol settings must be chosen correctly for the DVR control to work properly For details please check the description below Figure 22 DVR 19 e Baud Rate gt Baud Rate 2400 Protocol DVR 16 Select the baud rate for the connected DVR by pressing amp The options are 2400 4800 9600 19200 38400 57600 DVR ID 00 T
Download Pdf Manuals
Related Search
Related Contents
Hitachi KP-F500WCL User's Manual Model 750C User`s Manual Sweex Optimuo MP4 Player Green 4 GB 5400C Series DVR User Manual DETECTEUR PLAFOND MANUEL D`INSTALLATION Philips AZ5738 DVD CD Soundmachine BDF2015029 IM 21B04C50-01(5版) 変更票No.12-027 Manuel d`installation et de mise en service du contrôleur pour Wooden Camera 159500 Copyright © All rights reserved.