1. 29 7 5 Maintain Beeper Value Setting seen 30 Ghapter 8 Interface illa pis 31 8 1 OP 01 RS 232 RS 485 Serial Output with RTC 31 Chapter 9 Maintenance iier iiiece Aedes lia eL cce eta ipsa reati 33 9 1 Restore Default Setting for All Parameters General Certification 33 9 2 Restore Default Setting for Parameters OIML Certification 33 9 3 Restore Default Setting for General Function Parameters 33 9 4 Self test Mode a ee is sorrise ee 33 9 4 1 Program Version 35 9 4 2 7 segment Display Testing eese 35 9 4 3 Keypad amp Calibration Switch Testing 35 9 4 4 A D Conversion 35 9 4 5 EEPROM Testing peli aliena ia 35 9 4 6 Time amp Date 35 9 4 7 RS 232 Serial Output Interface Testing OP 01 35 Appendix 7 Segment Display Characters eere 36 1 ZSME300000148 Before using the product Thanks for your purchase of this indicator In order to operate it smoothly extend its durability and reduce the chance of breakdown please read this user manual car
2. 8 ZSME300000148 4 3 Battery Assemblage Pd ZSME300000148 Chapter 5 External Function Parameter Setting 1 Under general weighing condition press and the screen will show ENTER Press key Press key ENTER Press O to escape Back to weighing condition I pro I ril External function setting _ i IT i RS 232 RS 485 interface function 10 ZSME300000148 5 1 11 ri External Function Setting gt Key Disable m 2 ri 7 DSP Update Display Update gt F1 Setting F2 Setting Select the desired parameter code ENTER F2 Setting Backlight Function Setting Beeper Setting Maintain Beeper Value i gt Auto power Off The screen shows previous parameter setting Enter the desired parameter setting Press T F1 I I mo Press 5 to escape the setting Increase the flash value by one Decrease the flash value by one Move the cursor leftward Move the cursor rightward gt Save setting Abort setting or exit 11 ZSME300000148 amp External Function Parameter Settino Parameter Setting Value Default Code Ta Ton POTE coresen ng A Description Setting ds 0000 is corresponding to from left to 00 Key disable fight aero rune SH ra 0 000 i Bio
3. CSP 05 Unstable Detection Setting The symbol is standard for OIML Certification in context 21 ZSME300000148 i i Weight Calibration IIC LI Turn on and warm up the machine for 15 to 30 minutes before calibration Adjust the calibration switch to ON and the screen will show acc LI d 28 I Press or to select 1 1 IT III Procedure ENTER ENTER Zero calibration completed Zero ENTER Place n i ENTER Weight and set Y the 2 weight Set calibration switch to OFF J J and the screen Zero Calibration a Ensure nothing on the platter After the scale being stable press will display The zero calibration will be completed after 5 seconds b abort zero calibration just press ESC Weight Calibration scale to be stable then press The screen will show a Place an object which weight is known on the platter Input the weight value and wait the The weight calibration will be completed after 5 seconds b To abort weight calibration just press EC ZSME300000148 22 Password Setting Adjust calibration switch to ON After 2 seconds Input new password 5 70000 means no password Confirm new password After complete password setting when entering calibration mode or function setting mode the screen shows 1 _ for 1 second and then I LI IL ILL Its necessary to input the correct password t
4. Connection Description RS 485 Terminal Resistant EX0419 10 RS 06 10 Notice terminal resistant is built in the host interface it s not necessary to connect with another one from outside If the host computer is no signal ground SG it s not necessary to connect with it 32 ZSME300000148 Chapter 9 Maintenance 9 1 Restore Default Setting for All Parameters General Certification E calibration switch to ON during the countdown of power on press ES s hold them simultaneously 2 The screen will show 1i HZ FIL i ENTER IT l 3 To confirm press oen nd hold until showing 17111 and then adjust the calibration switch to OFF 9 2 Restore Default Setting for All Parameters OIML Certification 1 Agjust the calibration switch to ON during the countdown of power on press ae and hold them simultaneously 2 The screen will show Tu E I 3 To confirm press Jand hold until showing IL 1 and then adjust the calibration switch to OFF 9 3 Restore Default Setting for General Function Parameters 1 Press and hold simultaneously during the countdown of power on 2 The screen will show 111 ul I7 r4 3 To confirm press and hold until re turning on 9 4 Self test Mode 1 Press and hold it during the countdown of power on Fg 2 The screen will show I which means entered self test mode 3 Use
5. FNC 03 This is general certification option when the parameter is set for 70 in RS1 04 and the parameter is set for 6 RS1 00 amp Transmission Format RS1 00 0 3 S T G S 1 2 3 4 5 6 g CR LF A 1 2 Weight Data 8 digits Unit Terminators Header 1 ST Stable Weight US Unstable Weight OL Weight Overload Header 2 GS Gross Weight NT Net Weight TR Tare Weight Data 8 digits The first digit of weight data indicates value of weight The other 7 digits including decimal point indicate the weight value If the weight is over load Header 1 OL the screen only shows and decimal point Unit kg t or blank or kg Ib t or blank Terminators CR and LF are data termination code RS1 00 4 2 jor ur The symbol is standard for OIML Certification in context 15 ZSME300000148 RS1 00 5 RS1 00 6 telex x xx xx xx xere 5 js 1 2 erl r 2 o fere 2 forte E 2 4 spel RS1 00 7 telex x xx x x ener xx x 2 4 o
6. 2 and Pin 3 of the 9 pin D SUB socket of serial output Showing 7 1 1 1 represents in normal condition Showing represents abnormal condition 2 If connected with a computer protocol must be corresponding the screen will show DI Lg 11 to 1 which means RS 232 output is in normal condition 35 ZSME300000148 Appendix 7 Segment Display Characters Number Display Letter Display Letter EN EN EN Z _ 36 Display ZSME300000148
7. keys to select test program Press key to enter self test and press key to exit 33 ZSME300000148 Testing Program Version Number Displaying 7 Segment Display Testing Keypad and Calibration Switch Testing AID Conversion Value Displaying EEPROM Testing RTC Date amp Time Testing OP 1 RS 232 Serial Output Interface Testing 34 ZSME300000148 9 4 1 9 4 2 9 4 3 9 4 4 9 4 5 9 4 6 9 4 7 Program Version Number 7 Segment display shows program version number Press Een uen to show 1 General certification 2 OIML certification No meaning 7 segment Display Testing 7 Segment display shows LI to and Keypad amp Calibration Switch Testing Adjust calibration switch to ON and press any key the corresponding bit will be changed from to i A D Conversion Value 7 Segment display shows the internal value of the scale EEPROM Testing Dal i a Showing 1 ri _ represents in normal condition Showing ETE represents in abnormal condition RTC Time amp Date Testing Press key to enter the testing mode the screen will show date YY MM DD For example 05 11 03 represents 3rd of November 2005 Press key again to show time HH MM SS For example 09 45 50 represents 9 o clock 45 minutes and 50 seconds RS 232 Serial Output Interface Testing OP 01 1 Short Pin
8. value will be kept on the display if the weight is lower than 10d or you can push Enter key to reset weighing process then the screen will show 21 05 2 Animal Scale Mode 2 The weight value shows stable unstable weighing condition The weight value shows on the display under the stable or unstable weighing condition When the weight value reaches the range of CFN 06 and CFN 07 setting the screen will keep showing the weight value When the weight value is over the range of CFN 06 and CFN 07 setting the screen will show the normal weight measurement For example CFN 06 30 CFN 07 2 WT Weight Holding 30d ancellation of Weight Holding T 27 ZSME300000148 7 2 Dual Range Resolution Switch Function The dual range resolution will be available when the parameter settings of CSP 02 and CSP 03 are different 21 08 0 Multi interval If CFN 09 5 000 WT Division 2 Division 1 C CFN 08 1 Multi range If CFN 09 5 000 Recover when back to zero 28 ZSME300000148 7 3 21 FNC 02 FNC 03 setting is at parameter 6 Pre Tare Function uw 7 Under weight display status press key according to FNC setting the screen will show Input the desired Pre Tare value Press key Back to weight display status PT indication lights up Pre Tare Cancellation When the gross weight column shows 0 press key to
9. 1 Select the desired 1 Division 2 parameter code with ra rnm LUO IT a 0 I I LIU Zero Tracking Setting L1 gt Unstable Detection Setting The screen shows previous parameter setting Enter the desired parameter setting Press Press to escape the setting Increase the flash value by one Decrease the flash value by one Move the cursor leftward Move the cursor rightward Save setting ESC Abort setting or exit 19 ZSME300000148 amp Specification Parameter Description de Function aaa ig ae Setting Value Value Default Code Description j Setting Decimal Refer to descriptions in next page Point Maximum 999999 CSP 01 Weighing Y Max value for weight display 999999 Capacity 000000 CSP 02 Division 1 Min value for weight display Refer to descriptions in next page 0 25d Refer to descriptions in next page 0 25d Zero CSP 04 Tracking Setting Unstable CSP 05 Detectiion Setting BZ 5 B NI Bez L an CSP 03 Division 2 Min value for weight displa 2702 77 20 20 ZSME300000148 amp Parameter Display Description CSP 00 Decimal Point Display Decimal Point Digit d we d 56 at d 26900 Ades CSP 04 Zero Tracking Setting eene med eene IS 4 wn dem do otas E uu d La di NEN Y UN NEED
10. Mini Indicator User Manual Table of Contents Safety Precaution lag i dei 2 Chapter 1 Keypad Instruction c iii alianti niente tan cete rece canas 3 Ghapter 2SpecilicationS iaia iaia 4 Chapter 3 Front and Rear 5 3 1 EE E 5 3 2 Hear Panel a sr EID ATL SIUE 6 Chapter 4 Installation Ee 7 4 1 21212 EIL es 7 422 Dimensions DE 8 4 3 ee 9 Chapter 5 External Function Parameter Setting eese 10 5 1 Li d I 1 External Function Setting s 11 Soda ce cR a R8 232 Settings essen 13 Chapter 6 Internal Calibration 18 6 1 E d 8 Specification Calibration sess 19 6 2 1107 III Weight Calibration s csssssssssssssssssssssssssssssssssssssseessessen 22 6 3 11 1 i_ I r4 Internal Function Setting res 24 6 4 Error Messages iaia 26 Chapter 7 Special Funetion a 2 ee ee 27 7 1 Animal Scale Setting 2 2 ana a el 27 7 2 Dual Range Resolution Switch Function eese 28 7 3 Pre Tare Function ee es ee a 29 7 4 Resolution Switch Function
11. cancel the Pre Tare value 7 4 Resolution Switch Function 21 FNC 02 or FNC 03 setting is at parameter 5 x E Under weight display status press or key according to FNC setting the display will show 10 times of the original division value and it will return back to the original one after 5 seconds 29 ZSME300000148 7 5 Maintain Value Setting Mode 1 RS 232 transmission mode enters into HOLD value transmission mode automatically When the weight is higher than 10d the indicator holds the max value of weight Press key to ani unlock HOLD mode RS 232 tansmits one data of PEAK of HOLD value when press f Display 10d Enter key 835 232 transmission mode enters into HOLD value transmission mode automatically Mode 2 When the weight is higher than 10d the indicator holds the max value of weight When the weight is lower than 10d the indicator unlocks HOLD value automatically and shows the weight value which is lower than 10d RS 232 tansmits one data of PEAK HOLD value The data point is from PEAK HOLD value to lower than 10d Display 30 ZSME300000148 Chapter 8 Interface 8 1 OP 01 RS 232 RS 485 Serial Output with RTC Real Time Clock CN2 CN3 1 1 Short 1 and 2 pins to get RS 485 output Short 2 and 3 pins to get RS 232 output amp Pin Allocation of Rear Panel RS 485 interface is capable to connect up to 10 mini indicators 31 ZSME300000148
12. d Cell no backlight no RS 232 interface NiMH battery 36 hours General battery 60 hours 4 Please charge the Ni MH battery at least 12 14 hours for first use Others Operation Temperature 0 40 C Operation Humidity lt 85 Dimensions W x D x H mm 193 x 49 5 x 94 4 excluding protrusions 225 x 60 x 134 7 including protrusions Weight 700g 4 ZSME300000148 Chapter 3 Front Rear Panels 3 1 Front Panel 23 TARE MOTION M GROSS RANGEI HOLD RANGE2 ESC inim NET n FA pur Indication Battery is charged only available for rechargeable model 1 Battery is charging only available for rechargeable model TARE Tare mode MOTION Unstable weighing M Accumulation mode GROSS Gross weight PT RANGE1 HOLD Dual range resolution indication 1 RANGE2 Dual range resolution indication 2 Description of RANGE1 and HOLD The light is default on When using CFN 05 Animal Scale Mode or FNC 07 Maintain Beeper Value it works as HOLD LED light When opening dual range resolution it works as RANGE1 LED light CFN 05 Animal Scale Mode and FNC 07 Maintain Beeper Value can t be run at the same time Keypad Esc 1 Power OFF Press and hold this key for seconds to shut down 2 Abort or exit when setting N m 2 1 Weight backs to zero 2 Increase the flash value by one when setting TARE 1 Eliminate the gross w
13. efer to 9 3 for details Function Parameters hold During the operation use the following keys to complete all works gt Increase the flash value by one ka gt the cursor rightward ZERO ENTER Decrease the flash value by one Save setting Move the cursor leftward ESC gt Abort setting Exit 3 ZSME300000148 Chapter 2 Specifications Analog Specification Load Cell Current DC 5 V 5 60 mA Up to Four 350 O Load Cells Max Load Cell Input Voltage 16 mV Input Sensitivity 0 15 uV d or more Conversion Rate Approximately 120 times s max Resolution 20 bits Digital Specification Display LCD 6 digits 25 4 x 10 mm W x H LED backlight Display Frequency 50 times s max Display Range 999999 999999 Min Division 1 2 5 10 20 50 Decimal Point 0 0 0 0 00 0 000 0 0000 Memory Calibration parameters and function settings are all stored in EEPROM Optional Interface Card OP 01 RS 232 RS 485 Includes RTC Function Power Requirement Adaptor Spec Input 120 230 V AC 50 60 Hz Output 9 V 1000 mA Optional 2 types of batteries 6 V NiMH rechargeable battery kit 5 pcs 1800 mA hr or general batteries 5 pcs Max Power Consumption 110 mA with 4 Load Cells backlight RS 232 interface NiMH battery 15 hours General battery 24 hours 45 mA with 1 Loa
14. efully Safety Precaution Switch off the indicator before installation or dismantlement LU Keep the indicator away from the direct sun light The operation temperature is between 0 40 C The ground connection of this indicator is necessary and this ground impedance is less than 1000 Do not connect the ground with other equipments which need huge power consumption Non ground or incorrect connection might cause an electric shock or a product breakdown Please wait more than one minute before re power on 2 ZSME300000148 Chapter 1 Keypad Instruction Function Operation Description Press and hold fa General Function Refer to lt Chapter 5 gt External Function Setting Parameter Setting for details then press Setting for decimal point capacity Weighing Parameter Adjust calibration switch division zero tracking and unstable Setting detection etc Refer to 6 1 Specification Setting for details Adjust calibration switch Refer to 6 2 Weight Calibration for Calibration to ON details During the countdown of power on press and Refer to 9 4 Self test Mode Self test Mode hold for details Adjust calibration switch to ON and then Restore Default d Setting for All j Refer to 9 1 for details Parameters hold During the countdown Restore Default 91 Power on press and Setting for General R
15. eight J 2 Decrease the flash value by one when setting 2 o o 1 Switch Gross Net weight shown on display Move the cursor leftward when setting 2 1 Keypad function FNC 02 amp FNC 03 2 Move the cursor rightward when setting Keypad function FNC 02 amp FNC 03 Confirm key 5 ZSME300000148 3 2 Panel 1 Battery Case 2 RS 232 RS 485 Input Output 3 DC 9 V Power Input 4 Calibration Switch 5 Load Cell Connect Socket 6 ZSME300000148 Chapter 4 Installation 4 1 Load Cell Load cable I Loadcell er EXC Shield 4 wired 5 wired Load Cell 6 wired 7 wired Load Cell Pin 1 connects with SIG Pin 1 connects with SIG Pin 2 3 short to connect with EXC Pin 2 connects with SEN Pin 4 5 short to connect with EXC Pin 3 connects with EXC Pin 6 7 8 connect with shield Pin 4 connects with SEN Pin 9 connects with SIG Pin 5 connects with EXC Pin 6 7 8 connect with shield Pin 9 connects with SIG 7 ZSME300000148 4 2 Dimensions Pd EN Dn 1 arg 1 N K a 11 ZA V er NW
16. ferl r N E T 4 sfe 2 4 o ferry Pit o fore Sp oe p 2 4 16 lerr 16 ZSME300000148 amp Command Mode Command Function READ RW Tare Clearing ZERO MZ Weight Re zeroing RI Weight Accumulation TARE MT Times Accumulation NTGS Gross Net Switch MG Gross Weight Indicating Ro e Weight and Times MN Net Weight Indicating Accumulation DT Weight and Times Accumulation Clearing After setting above commands it must add the termination code CR and LF OAH Ifthe command is not correct it shows E Command Unidentified If the command mode is chosen with address RS1 01 4 add address in front of each command Example When RS1 06 1 for reading weight value the whole complete command should be 01RW CR LFY ZSME300000148 Chapter 6 Internal Calibration Adjust calibration switch to ON and the screen displays After 2 seconds Adjust calibration switch back to OFF II i Specification Calibration ili I Ii Weight Calibration I LI og LL rt Internal Function Setting 18 ZSME300000148 Specification Calibration Parameter Code Press ENTER _ LIL gt Decimal Point 5r i f Maximum Weighing Capacity ar LIC Division
17. ndition Animal Scale CFN 05 Mode 1 1 0 Animal Scale Mode 2 Stable Range Setting CFN 06 0 100 parameter is less than 1 Stable Range equal to 10 Animal Scale CFN 07 Sampling Frequency 128 times Multi interval CFN 08 Muti ineva ESON SEINY 1 Multi range Midpoint Setting CFN 09 for Dual Range 0 999999 Sethe demarcation point for dual sooo range resolution Resolution Sa OSA Gravity calibration for the different CFN 10 Gravity Calibration 9 83218 UNG SBOE z006 9 79423 1 Zero when Scale turned on Operation of ON Accumulative 1 Value Times upon Unstable Condition 1 OFF The symbol is standard for OIML Certification in context CFN 11 25 ZSME300000148 6 4 Error Messages 1 LI Load Cell or A D circuit is abnormal 2 c Real weighing value is lower than or equal to zero value 6 Internal resolution is lower than 0 15 pV d range 4 OE Incorrect password 5 E i Internal value is lower than zero range 6 c Internal value is higher than zero range 26 ZSME300000148 Chapter 7 Special Function 7 1 Animal Scale Setting 05 1 Animal Scale Mode1 The weight value won t be shown if the weighing condition is unstable When there is nothing on the platter the screen will show When an object is on the platter take a 20 gram object for example the screen will show The weight
18. o continue each setting If the input password is incorrect the screen shows BR 23 ZSME300000148 6 3 11H LF Internal Function Setting ENTER Press Select the desired parameter code with The screen shows previous parameter setting Enter the desired parameter setting Press ENTER Press O to escape the setting Parameter Code 24 gt Tare or Zero Function under Unstable Status Zero when Scale Turned on Back to Zero Range Filter Sampling Rate Filter Strength Animal Scale Mode Animal Scale Stable Range Animal Scale Sampling Frequency Dual Range Resolution Setting Midpoint Setting for Dual Range Resolution Gravity Calibration Operation of Accumulative Value Times upon Unstable Condition ZSME300000148 amp Internal Function Parameter Description Parameter Setting Value Default Code Parameter Setting Tare or Zero CFN 00 Function under Unstable Status OFF 0 Full range re zero 1 30 Capacity x setting CFN 02 Back to zero range 0 30 value 2 The parameter is less than or equal to 2 Filter Sampling The larger number setting the CFN 03 Rate lower speed rate is 1 1 CFN 04 Filter Strength 0 5 The larger number sening the 2 stronger filter is Mode 1 The weight value won t be shown if the weighing condition is unstable Mode 2 The weight value shows in stable or unstable weighing co
19. s cms FNC 01 DSP Update re ae lene Accumulation Display Switch 6 Pre Tare function ___0 Print printing el Accumulation Display Switch 6 Pre Tare Pre Tare function 0 Print printing ENTER F2 Accumulation Display Switch 6 Pre Tare Pre Tarefuncion Lee 4 Auto Backlight On FNC 05 Backlight backlight on in operation only 1 Setting 2 Bee Setting 1 Beeperon TT Maintain 0 No function FNC 07 Beeper Value 0 Nofuncion Auto power FNC 08 Off Minutes It works when the weight is stable and non key is pressed in weighing mode amp l The symbol is standard for OIML Certification in context 12 ZSME300000148 52 1111 m 1 RS 232 Setting Parameter Code Select the 75227 parameter code with parameter setting Enter the desired parameter setting Press The screen shows previous ENTER Press to escape the setting gt Information Pattern Transmission Method Transmission Rate gt Bit Length Stop Bit Unstable or Over Load Auto Transmission Condition Command Address Output Format Transmission Times Date Setting Time Setting Increase the flash value by one Decrease the flash value by one gt Move the cursor leftward Move the cursor rightward Save
20. setting Abort setting or exit ZSME300000148 amp 01 RS 232 RS 485 Interface Function Setting Value Default Descripion Setting See T1 Information 3 Tee Continuous Transmission Ta Transmission Press or for Command Mode no address Command Mode with address 200 1 400 2 Transmission Method Se Rate 4 800 9 600 No Parity N 8 1 8 Bits Length 1 Stop Bit Parity Odd Parity Bit Length 1 0 7 1 7 Bits Length Stop Bit 1 Stop Bit Even Parity 2 E 7 1 7 Bits Length 1 Stop Bit RS1 04 Unstable or 0 Continuous Output Over Load 1 Stop Output Auto Positive over 10d RS1 05 Transmission Positive Negative Condition over 10d under 104 Command ri Available only if RS1 01 setting is RS1 06 ja Address 4 Standard Format RS1 07 output Fomap _1 The symbol is standard for OIML Certification in context 14 ZSME300000148 __ Transmission 2 2timess Times 3 5 d20timess RS1 09 Date Setting _ 2510 Time Setting Remark This is general certification option when the parameter is set for 0 5 RS1 00 and the data is transmitted to printer This is general certification option when the parameter is set for 6 in RS1 00 and the parameter is set for 6 in FNC 02 or the parameter is set for 6 in