Home
USER MANUAL - Mr Security
Contents
1. Fig 1 Layout of the RP208KCL 7 Tamper Keypad Instruction 8 key press 1 Power 9 Stay key press 2 LCD Display 10 Buzzer 3 Am 11 Exit Delete key press 4 Disarm 12 Digit and Function key 5 Bypass press 6 Fire LED Indication and Keys 1 Power LED On The system is operating correctly from commercial AC power and its backup battery is in good condition Off The system is inoperative due to the lack of power from both commercial AC and backup battery Flash Indicates a trouble condition 2 LCD Display The LCD Display on RP208KCL indicates the status of the system including each of the zones Triggered Armed Disarmed system Trouble Time and other programming information If there is only Guard8 on the display this means that all the zones are closed or are not triggered When Z1 Z2 Z3 Z4 Z5 Z6 Z7 or Z8 is are displayed on the display which means the zone is open or triggered Statue Explanation System Disarmed System Armed GUARDS All the zones are secured and working normally Zi Zone 1 was An alarm has occurred on triggered Zonel 22 Zone 2 was An alarm has occurred on triggered Zone2 78 Zone 8 was An alarm has occurred on triggered Zone8 3 ARM LED The ARM LED indicates whether or not the system is armed In armed condition the ARM LED is on in case of any violations there will be an alarm The ARM LED
2. By Roiscok Electronics USER MANUAL FOR MODEL RP208CN 15 11 07 This page is intentionally blank INDEX CHAPTER 1 SUMMARY OF USER S 8 00 3 CHAPTER 2 ABOUT THE KEYPAD uiri ato rte enr tht oed emet 4 RP208KCL LCD KEYPAD 4 LED INDICATION AND KEYS Ier 5 FUNCTION AND OPERATION 7 1 SETTING CHANGING AND DELETING USER S CODE 7 SETTING DATE AND TIME 9 3 DISPLAYING SYSTEM DATE AND 9 4 SETTING FOLLOW ME PERSONAL DIALING NUMBERS 9 5 QUICK ARMINQG iet sat dese n deg bes 10 6 CODE ARBMING ii etm oor iei runde ecb 10 7 BELL SQUAWK ON ARMING eee e eee 11 8 DISARMING irte ae ae E i eG eid i 11 9 ON OFF AUDIBLE KISS OFF et ttn oe dide 11 10 DURESS 11 11 CUTTING OFF SOUNDER AND STOP AUTO DIALING 12 12 BYPASSING UN BYPASSING 2 2 2 12 13 ESCAPE KEY ESO an rrr dioe tee e idt eo cese re Ed ae 12 14 EMERGENCY KEYS oce tet ese lequel ee 13 15 ENTRY AND EXIT 5 0 22 13 16 24 HOUFRCZONE inue iR eA e een ERR eris 13 17 TROUBLE DISPLAY vine uic ec Ee te a ake 13 18 ZO
3. company has investigated and you feel confident that the burglar is no longer on your premises Disarming an armed system Before the Entry expires enter the four digits of your User Code NOTE If you make a mistake when entering your User Code the keypad will produce three short beeps and the LCD keypad will display error If so press ECS and re enter the Code 12 Bypassing Un bypassing a Zone When an intrusion zone is bypassed the zone will not be armed when arming When disarming all the bypassed zones will be automatically un bypassed There are two methods of Bypassing Quick Bypassing It s defaulted that all the zones of GUARDS can be set as Quick Bypass Bypass a zone simply press the corresponding key for or above 2 seconds For example to bypass Zone 3 press digit 3 for 2 seconds then By Pass Z3 will be displayed on the LCD which means Zone 3 has been bypassed successfully Use the same way to un bypass the bypassed zone When Zone 3 is un bypassed Cancel BP Z3 will be displayed on the LCD Code Bypassing If GUARD8 was programmed as code bypassing then press 1 Disarming Code Zone No to bypass the zone Use the same way to un bypass the zone 13 Escape Key ESC Keypad ESC is used for correction 14 Emergency Keys GUARD8 Keypad RP208KCL provides three emergency keys which can be pushed at anytime and the police fire department or medical emergency assistance is required Emergency Alarm is d
4. phone No 1 Set follow me phone no 2 7 2 master code phone No 2 f Set follow me phone no 3 7 8 master code phone No 3 Set follow me phone no 4 7 4 master code phone No 4 On off buzzer 8 master code 1 On off door chime 8 master code 2 Audible kiss off 8 master code 3 Display memory 9 master code enevt number Test system 0 master code keypad panic alarm 1 2 at leadt 2 seconds keypad fire alarm 4 5 at least 2 seconds keypad special emergency 7 8 at least 2 seconds Escape ESC LCD Trouble Battery Low The Backup Battery Power is low AC Power AC Power is lost Trouble Table No Clock Clock have not been set No The Communication is Communication trouble No Siren The Siren connection is in trouble CHAPTER 2 ABOUT THE KEYPAD RP208KCL LCD Keypad The GUARDS supports the LCD Keypad Each control panel can work with four LCD Keypads Each keypad in your system reports its status by its LED lighted indicators and its LCD display Through its keys you can enter commands to Arm and Disarm the system bypass intrusion zones report emergencies stop the siren checking the trouble display programming the system and other functions ROISCOK
5. using the LCD keypad up to 50 events including arm disarm alarm etc Events are presented from the last entered to the first registered The event are listed in chronological order from 1 to 50 using the following codes for identification Press 9 MASTER CODE EVENT No The keypad display format is as follows MM DD HH MM ID CODE Zone No or User Identification Code 11 Zone Alarmed 10 Zone Restore 21 Keypad Panic Alarm 22 Keypad Fire Alarm 23 Keypad Medical Emergency 51 User Arm 50 User Disarm 53 Auto Arm Zone No or User No When the event shows an activation the last code number identifies the activated zone When the event is for arming or disarming the last code number identifies the User No 20 On Off Door Chime Assigned to an opening which when violated during the disarmed state will cause the system s keypad s to beep once When alarm occurs during armed system only the external sounder will be activated Enter 8 Master Code 2 to turn on off the door chime 21 Remote Control System optional If your system has been installed with the remote control option the following buttons may be used and pre programmed as per the following table When arming or disarming a remote control system a confirmation chirp will indicate its status whether it is armed or disarmed Button 1 Button 2 Button 3 Button 4 Arm amp Disarm Panic Button if programmed by installer Ga
6. CS and re enter the above sequence correctly 9 On Off Audible kiss off When the system is disarmed Press 8 User s Code 3 to on off the buzzer 10 Duress Disarming If you are ever coerced to disarm your system you can comply with the intruder s wishes while sending a silent duress alarm to the Central Station To do so you must use a special Duress Code Which when used will disarm the system in the regular manner while simultaneously transmitting a silent alarm to the central station All 10 codes including one Master Code and 9 User Codes can activate the Duress disarming by adding 1 to The last digit of your user codes Example If your code is 1 2 3 4 your duress code is 1 2 3 5 If your user code is 7 8 9 0 your duress code is 7 8 9 1 Note Under no circumstances must the Duress Code be used haphazardly or without reason Central Stations along with Police Departments treat Duress Codes very seriously take immediate action 11 Cutting off Sounder and Stop Auto dialling If outside the premises open an entry door the keypad s will beep indicating that the Entry Delay period has begun The entry delay is defaulted as 30 seconds SILENCING AN ALARM IN PROGRESS Observe the keypad If any of the following conditions is evident an alarm has occurred The ARM LED is flashing 21 22 23 are displayed on the LCD It s best to enter the premises only after police or a security
7. Code 3 press 3 The other Codes can be set deleted in the same way 4 Enter the new User Code For example 3 3 5 5 5 If successful the keypad will emit a confirming tone Beep The selected User Code is now in effect DELETING USER S CODES At times it may be desirable to completely delete a User Code Note that it is impossible to delete the Master Code although it can be changed Step Operation The system must be disarmed Enter the User 1 Functions Mode and choose Codes 5 Press 5 2 Enter the current 4 digit Master Code 5 6 7 181 To delete the User Code1 press 1 To delete the User Code1 press 2 3 To delete the User Code1 press 3 The other Codes can be deleted in the same way 4 Enter the If successful the keypad will emit a one second 5 confirming tone The selected User Code is now deleted 2 Setting Date and Time Set date 6 1 MASTER CODE MM DD YY Month Date and Year should all be two digits Set time 6 2 MASTER CODE HH MM Use a 24 Hour format Hour and Minute should be two digits For example if you want to enter 16 28 August 18 2006 operate as 6 1 MASTER CODE 08 18 06 6 2 MASTER CODE 16 28 3 Displaying System Date and Time Press 4 to check the system time on LCD keypad And the format should be MM DD YY Hour Minute 4 Setting Follow me Number In c
8. NE FEATURES uinea ee tse tasse 14 19 EVENT HISTORY MEMORY 15 20 ON OFF DOOR CHIME nite ttd redit ese tef 15 21 REMOTE CONTROL OPTIONAL HH 16 WARRANTY INFORMATION 20 GUARD8 0 17 CHAPTER 1 SUMMARY of USER S COMMANDS The Summary of User s Commands offers installers and users quick and convenient way to operate the control panel All can be done in the disarmed state and you do not need to enter programming state For detailed information please go chapter 2 Function Procedure Quick arm ARM Arm by code ARM master code Arm within zones STAY Arm within zones by code STAY master code System disarm user code Bypass disarm duress code Free from siren user code Bypass un bypass zone 1 2 user code zone number Quick bypass un bypass zone zone Jat least 2 seconds Display trouble 1513 Display time 144 Set change main code b master code 0 new code Set change a user code b master code 1 9 new code Set date 6 1 master code MM DD Y Y Set time 6 2 master code H H M M Auto arm time 6 3 master code H H IMIIV Set follow me phone no 1 7 1 master code
9. ase of an alarm event a phone call can be made to one or more predefined phone numbers There are three different tone types that represent burglary fire and special emergency alarms The Follow Me function can support four phone numbers for each system Make sure the numbers all correct then enter Operate as Set Follow Me Phone NO 1 7 1 MASTER CODE Phone NO 1 Set Follow Me Phone NO 2 7 2 MASTER CODE Phone NO 2 Set Follow Me Phone NO 3 7 2 MASTER CODE Phone NO 3 Set Follow Me Phone NO 4 7 2 MASTER CODE Phone NO 4 5 Quick Arming GUARD8 can be divided as interior zones and external zones by programming Zone 7 and Zone 8 are defaulted as interior zone Press ARM and all the zones will be armed Press STAY then only the external zones or unoccupied zones will all be armed and the interior zones will be disarmed Step Operation Before you arm your system all of its zones must either be secured or bypassed The keypad s READY 1 LED if lit indicates that all zones are secured If the READY LED is not lit one or more unsecured zone s will be display on the LCD Quick Arming and Code Arming Quick Armed Armed the system just by pressing 2 ARM Quick Stay Armed Stay Arm just by pressing STAY 3 Three short Beep from the keypad when there are some errors in entering Then re operate it When arming the system there will be one co
10. ck Clock have not been set No The Communication is in Communication trouble No Siren The Siren connection is in trouble 18 Zone Features GUARD8 has 8 programmable zones Each zone can be programmed for Entry Exit Delay Zone Instant Intrusion Zone Panic Zone Fire Zone Tamper Zone Remote Zone etc Entry Exit Delay Zone A delay period was setup during your system s installation to provide suitable time to allow for your entry and exit Exit Delay is the time from pressing the ARM key to exiting the armed zones Entry Delay is the time from entering the armed zones to DISARM If the time exceeds the selected entry time the system will alarm at once Instant Intrusion Zone When it is triggered the system will alarm instantly Panic Zone Used for panic button which is 24 Hours Zone Fire Zone Used for smoke detector and gas detector which is 24 Hours Zone Tamper Zone Used for connecting with the tamper connector of detector which is 24 Hours Zone Remote Zone Used for connecting with remote receiver which is 24 Hours Zone For user s convenience all GUARDS zones have been defaulted as following Zone 1 Entry Exit Delay Zone Zone 2 Instant Intrusion Zone Zone 3 Instant Intrusion Zone Zone 4 Panic Zone Zone 5 Fire Zone Zone 6 Tamper Zone Zone 7 Interior Zone Zone 8 Interior Zone 19 Events History Memory Logger You can retrieve events from the events memory logger
11. e about the premises even after the system is armed Stay Arming arms the perimeter detectors eg door and windows lounge while leaving interior detectors eg bedroom motion detectors disarmed bypassed When you press the STAY key the interior or occupied zones will not be armed 10 EXIT DELETE ESC Key ESC is used for correction in the system operation 11 DIGIT KEYS When programming key in 0 9 digits 12 FUNCTION KEY 4 When programming key 4 is for entering function mode and confirmation Function and Operation KEYS AND FUNCTIONS The Keys can support the following functions Enter digit s for Arming Disarming Panic Alarm Programming etc Enter user s function mode Key ARM is for Quick Arming and Code Arming By pressing it the system will be fully armed Key STAY is for Quick Stay Arming and Code Stay Arming By pressing it to arm only some of the zone will be armed Each zone can be set as interior zone or external zone When you use STAY for arming the external zone will be armed and the interior zones will be disarmed Under the disarmed status press to enter user s function mode Reference to CHAPTER 1 SUMMARY of USER S COMMANDS 1 Setting Changing and Deleting User s Code The default Master Code of the GUARDS is 1 2 3 4 Unless your alarm installation company has already changed it to suit your preference It s best to modify this code to one which is unique and personal
12. efaulted as silence alarm Press 1 and 2 simultaneously and for at least two seconds will activate a Panic Alarm note this is silent and cannot be audible Press 4 and 5 simultaneously and for at least two seconds will activate a Fire Alarm This is an audible alarm Press 7 and 8 simultaneously and for at least two seconds will activate a Medical Emergency if system is monitored 15 Entry and Exit Delays Your security system must allow you to enter and leave the premises to give time to arm or disarm the system A delay period was chosen during your system s installation to provide suitable time to allow for your entry and exit Entry Exit Delays can be set by programming and it s defaulted as 30 seconds 16 24 Hour Zone GUARDS can support several kinds of zones All other forms of protection including fire and 24 hour panic alarms le police fire and medical are always ready 24hrs to report alarms whether System is armed or not 17 Trouble Display When the keypad sends out three short beeps regularly this indicates the system has a fault Once the trouble conditions are cleared the system will restore to normal status and stop beeping Troubles include Battery Low AC power No Clock No Communication No Siren etc Press 3 to search on the LCD The troubles displayed as follow LCD Trouble Battery Low The Backup Battery Power is low AC Power AC Power is lost Trouble Table No Clo
13. is flashing which means burglary fire or emergency alarm once has or have occurred in the corresponding zone s The ARM LED is off when the system is disarmed Statue EXPLANATION When the system is armed in case of any emergency an alarm will occur The Siren will sound and system will also dial the follow me numbers and send alarm report to alarm center Off The system is disarmed Flashing Burglar fire and or has have once occurred On 4 READY LED The Ready LED indicates whether the system is working normally or not and also indicates whether system can be armed or not When disarmed the LED will be on when armed the LED will be off STATUS EXPLANATION On All the zones are working normally so the system can be armed now Off 1 Someone is moving in the zone 2 The system is armed Flashing The system is under the programming status 5 BYPASS LED The BYPASS LED Indicate that one or more of the system s intrusion zones have been bypassed See later in this manual for more information 6 FIRE LED When in Fire Alarm the Fire LED will flash 7 TAMPER LED When the detector s or the keypad is are tampered or destroyed a Tamper Code report will be sent and the LED will flash 8 SYSTEM ARMING ARM When you press the ARM key all the zones will be armed 9 STAY HOME ARMING STAY Home Arming or Stay Arming allows individuals to remain inside and mov
14. ised GUARDS can have up to 10 Codes one is Master Code and the other 9 are User s Codes To change the Master Code and or to set up User Codes follow the steps Make sure the system is disarmed when setting the code The User s Codes are only for Arming and Disarming the system Functions of the Master Code Adding changing and deleting User s Code Setting Time Clock Operating and testing Setting the follow me numbers Setting Changing the master Codes Step Operation 1 The system must be disarmed the ARMED LED will be OFF Enter the User Functions Mode 5 2 Enter the current 4 digit Master Code For example Press 1 2 3 4 Press 0 Enter the new 4 digit code selected will emit a one 4 second confirming tone The selected User Code is now in effect For example press 5 6 7 8 5 If successful the keypad will emit a confirming tone Beep The selected User Code is now in effect SETTING CHANGING 1 9 USER CODES At times it may be desirable to completely delete a User Code Note that it is impossible to delete the Master Code although it can be changed Step Operation 1 The system must be disarmed Enter the User Functions Mode and choose Codes 5 Press 5 Enter the current 4 digit Master Code 2 For example 516 1718 To set delete the User Code 1 press 1 To set delete the User Code 2 press 2 3 To set delete the User
15. nfirmation sound which means the exit delay 4 begins now You now leave the premises before the exit delay time is over to avoid false alarm The exit delay time is defaulted as 30 seconds 6 Code Arming Your GUARDS offers two methods of arming Quick Arming and Code Arming Its defaulted as quick arm If the user requires code arm it should be set when programming in advance When GUARDS is set as code arm it can not support ARM and STAY for quick arming And it should be operated as ARM Master Code or STAY Master Code to arm or stay arm 7 Bell Squawk on Arming If selected Bell Squawk on Arming will produce brief confirmation chirp from the system s external sounder s once the system is armed and the Exit Delay expires If you have a remote control system a confirmation chirp will confirm alarm state 8 Disarming GUARDS can set 10 Codes 4 digits one Master Code and 9 User Codes In arming status simply enter any code of the 10 codes to disarm Step Operation When entering the arming zone the keypad wvill beep which means the system is in entry delay status The entry delay time is defaulted as 30 seconds Disarming an armed system Before the Entry Delay expires enter the four digits of your User Code Or it will alarm 2 NOTE If you make a mistake when entering your User Code the keypad will produce three short beeps and the LCD keypad will display error If so press E
16. perty loss as a result Consequently Seller shall have no liability for any personal injury property damage or loss based on a claim that the product fails to give warning However if seller is held liable whether directly or indirectly for any loss or damage arising under this limited warranty or otherwise regardless of cause of origin sellers maximum liability shall not exceed the purchase price of the product which shall be the complete and exclusive remedy against seller No employee or representative of Seller is authorised to change this warranty in any way or grant any other warranty All products should be tested at least once a week This page is intentionally blank ROISCOK Copyright 2007 Mr Secuirty All rights reserved The Manual is not to be reproduced without permission Phone 0800 022 111
17. rage Door Gate Control Garage Door Gate Control GUARD8 Warranty ROISCOK Electronics Ltd Mr Security Ltd and Affiliates Seller warrant its products to be free from defects in materials and workmanship under normal use for 18 months from the date of production or 12 months from date of installation whichever is sooner Because the Seller does not install or connect the product and because the product maybe used in conjunction with products not manufactured by Seller seller cannot guarantee the performance of security system which uses this product Seller s obligation and liability under this warranty is expressly limited to repairing or replacing at Sellers option within a reasonable time after the date of delivery any product not meeting the specifications Sellers obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct indirect or consequential or delay Seller does not represent that its products may not be compromised or circumvented that the product will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the product will in all cases provide adequate warning or protection Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary robbery fire without warning but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or pro
Download Pdf Manuals
Related Search
Related Contents
Lightolier FC28U_3d User's Manual 保証とアフターサービス(つづき) Samsung RT27JARZESP User Manual(INDIA) - VisionID Triarch 31164 User's Manual Density.m4l v.2 - Alessandro Petrolati User Manual Copyright © All rights reserved.
Failed to retrieve file