Home
Installation and User Manual ROCHER DET
Contents
1. Check page 9 Table 2 for a suitable fuse size A and the correct diameter of the power supply cable mm for the sauna heater in question Conform to the specified safe clearance around the sauna heater Please refer to Table 1 on page 9 There should be enough room around the sauna heater for maintenance purposes Also a doorway can be considered as a maintenance area 2 8 Installation Follow the safety clearance specifications on page 9 when installing the sauna heater The sauna heater is a floor standing model The base must be solid because the sauna heater weighs about 120 kg The sauna heater is levelled by the adjustable legs The sauna heater is fixed on the floor from its legs by the provided metal fasteners 2 pcs This will keep the safety clearances intact during use Mounting of the sauna heater to the wall or the sauna benches available as an accessory metal fastenings S ZH 58 0043272 Walls or ceilings must not be clad with fibre reinforced plaster board or other light weight cladding because they may cause a fire hazard Only a single sauna heater is allowed per sauna room Installation and User Manual ROCHER DET 2 9 Preparing for piling the stones Removing of the supporting bars to pile the stones Unscrew the bars mounting screws 2 pcs Lift the support bar s locking plate up from its normal position Lift off the support bars Pile stones up to the Helo marker Reinstall the supp
2. fuses O O O O aA A A C 0 wo C CO N O O O 12 13 14 14 11 12 13 Installation and User Manual ROCHER DET 3 1 Quick instructions for use of the sauna heater 1 1 Check before taking a sauna bath 1 The sauna room is suitable for taking a sauna bath 2 The door and the window are closed 3 The sauna heater is topped with stones that comply with the manufacturer s recommendations the heating elements are covered with stones and the stones are piled sparsely NOTE Ceramic rocks are not allowed 1 2 Operation of the sauna heater controls Refer to the specific control panel operating instructions For additional information about enjoying a sauna bath please visit our website at www helo fi 2 Information for users Persons with reduced physical and mental capacity sensory handicap or little experience and knowledge about how the device is operated e g children should only operate the device while supervised or according to instructions given by the persons in charge of their safety Make sure that children aren t playing with the sauna heater 2 1 Sauna room The walls and ceiling of a sauna room should be thermally well insulated All surfaces that store heat such as tiled and plastered surfaces must be insulated It is recommended to use wooden panel cladding inside the sauna room If there are heat storage elements in the sauna room such as decorative stone glass etc note that these ele
3. 1 Safety clearances 2 12 Connection of the sauna heater to the mains The sauna heater must be connected to the mains by a qualified electrician and in compliance with current regulations The sauna heater is connected with a semi permanent connection Use HO7RN F 60245 IEC 66 cables or a corresponding type Other output cables signal lamp electric heating toggle must also adhere to these recommendations Do not use PVC insulated cable as a connection cable for the sauna heater A multipolar e g 7 pole cable is allowed if the voltage is the same In the absence of a separate control current fuse the diameter of all cables must be the same i e in accordance with the front fuse The connecting box on the sauna wall should be located within the minimum safety clearance specified for the sauna heater The maximum height for the connection box is 500 mm from the floor See page 10 Image 4 Location for the connection box If the connection box is located at over 500mm distance from the heater the maximum height is 1000mm from the floor Sauna heater insulation resistance The sauna heater heating elements may absorb moisture from air e g during storage This may cause leakage currents The moisture will be gone after a few heating sessions Do not connect the heater power supply through a ground fault interrupter However adhere to the effective electrical safety regulation when installing the sauna heater Sauna heaters
4. S hk l mmityksen vuorottelu El f rregling av annan el f rbrukare Signal kontakt Signal contact 3 Saunavalo Bastu belysning Saunabeleuchtung Sauna light max 100W 4 Ohjauskeskus Styrpanel Steuerger t Control panel 5 Tuntoelin Sensor F hler Sensor 354 SKLT 10 A Image 8 Wiring diagram for the sauna heater Installation and User Manual ROCHER DET 3 Rocher DET spare part list 4 ROHS 14 Heating element SEPC 200 3500W 230V Ymp rist n suojeluun liittyvi ohjeita T m n tuotteen k ytt i n p tytty sit ei saa h vitt normaalin talousj tteen mukana vaan se on toimitettava s hk ja elektroniikkalaitteiden kierr tykseen tarkoitettuun ker yspisteeseen Symboli tuotteessa k ytt ohjeessa tai pakkauksessa tarkoittaa sit Valmistusaineet ovat kierr tett viss merkint ns mukaan K ytettyjen laitteiden uudelleenk yt ll materiaalien hyd ynt misell tai muulla uudelleenk yt ll teet arvokkaan teon ymp rist mme hyv ksi Tuote palautetaan ilman kiuaskivi ja verhouskivi kierr tyskeskukseen Tietoa kierr tyspaikoista saat kuntasi palvelupisteest Instructions for environmental protection This product must not be disposed with normal household waste at the end of its life cycle Instead it should be delivered to a collecting place for the recycling of electrical and electronic devices The symbol on the product the ins
5. Sauna heater s Sauna heater s connection cable connection cable connection cable HO7RN F HO7RN F HO7RN F 60245 IEC 66 60245 IEC 66 60245 IEC 66 mm j mm 230 240V 1N 2 Table 2 Connection cable and fuses Installation and User Manual ROCHER DET 10 2 13 Locating the connecting box for the connection cable in the sauna room 500 mm Image 4 Location for the connection box 100 mm Specified minimum safety clearance 1 Recommended location for the connecting box 2 Silumin box recommended in this area 3 This area should be avoided Always use a silumin box In other areas use a heat resisting box T 125 C and heat resisting cables T 170 C The connection box must be clear of obstacles When installing the connection box to zones 2 or 3 refer to the instructions and regulations of the local energy supplier Installation and User Manual ROCHER DET 11 2 14 Safety distances Corner and wall installation OLET 28 N Absolute measurement must not be exceeded or undershot Safety clearances between the bottom of the sauna heater and a wall Fixing the sauna heater on the floor NOTE fixing of two 2 legs N Middle installation I N Hearters leg Floor zu E ed pem Metal fastener OLET28 Adjustable B leg j X u F A TP 60 OLET 28 NOTE All the dimensions are minimum dimensions unless otherwise mentioned NOTE If the sauna he
6. anty does not cover defects resulting from poor ventilation caused by small and tightly packed stones Ceramic rocks are not allowed They may cause damage to the sauna heater that will not be covered by the warranty Installation and User Manual ROCHER DET 6 2 5 Electric heating toggle The electric heating toggle applies to homes with an electric heating system Sauna heater has a connection marked 55 for controlling the electric heating toggle Connector 55 and the heating elements are simultaneously live 230V 2 6 If the sauna heater will not heat up If the sauna heater will not heat up please check that the power is on the main fuses of the sauna heater are intact is there any error messages on the control panel In case of an error message on the control panel please refer to the control panel instructions THE PERSON INSTALLING THE SAUNA HEATER SHOULD LEAVE THESE INSTRUCTIONS AT THE PREMISES FOR THE FUTURE USER 2 7 Preparing for sauna heater installation Check the following before installing the sauna heater The ratio of the heater s input KW and the sauna room s volume m Volume recommendations are presented in Table 1 on page 9 The minimum and maximum volumes must not be exceeded The sauna room height must be a min of 1900 mm Uninsulated and masonry stone walls extend the preheating time Each square metre of plastered ceiling or wall surface adds 1 2 m to the sauna room s volume
7. ater is installed further than 60mm off a wallora corner the installation method is always middle installation The thermostat must be installed in the ceilina as per instructions Installation and User Manual ROCHER DET 12 2 15 Principle image when T1 is used as control panel Connector strip Limiter ee 11 Valk Vit White Weiss Heater 12 Musta Svart Black Schwarz TN 13 Vihrea Gr n Green Gr n 14 Kelt Gul Yellow Gelb a MAMIL ULL A 15 Harm Gr Grey Grau 4 16 Rosa Ljusr d Pink Rose SENSE ue E 17 Sin Bl Blue Blau EE 18 Pun Rod Red Rot opolo 11 12 13 14 15 16 17 18 19 20 21 Control panel T1 Sensor OLET 28 i Control panel T1 NOTE See the sauna heater instruction for correct installation location P d Silicone 4 x 0 25 N LiYCY 10 x 0 25 Sauna heater Input 230 240V 1N 2 230V 3 Image 7 Principle istallation Installation and User Manual ROCHER DET 2 16 Wiring diagram Teho Effekt Lampovastukset Varmeelement Tennid Input Potencia Heating elements Heizeelement Resistores Termicos Leistung 230 V Voimsus SEPC 199 SEPC 200 BENE ENEEIESXM 1112 1314 1516 ic deo amp n L1 L2 L3 dy aw N 55 NI Katso ohjauskeskuksen kayttoohje 1 I I I Se styrpanelens bruksanvisning Sehe die Bedienungsanleitung des Steuerger tes See the control panel manual ZZ 3 1 Sy tt N tet Stromnetz Power input 2
8. helo GENUINE SAUNA amp STEAM Installation and User Manual ROCHER DET ELECTRIC SAUNA HEATER 1118 701 040518 1118 1051 040518 CONTROL PANEL 1601 27 RA 27 T 1 314 SKLT 51 3 A Installation and User Manual ROCHER DET Contents 1 Quick instructions for use ofthe sauna heater 1 1 Check before taking a sauna bath 1 2 Operation of the sauna heater controls 2 Information for users 2 1 Saunaroom 2 2 Recommended sauna room ventilation 2 3 Heating the sauna 2 4 Sauna heater stones 2 5 Electric heating toggle 2 6 Ifthe sauna heater will not heat up 2 7 Preparing for sauna heater installation 2 8 Installation 2 9 Preparing for piling the stones 2 10 Installing the support for heating elements 2 11 Sauna heater safety clearances 2 12 Connection of the sauna heater to the mains 2 13 Locating the connecting box for the connection cable in the sauna room 2 14 Safety distances 2 15 Principle image when T1 is used as control panel 2 16 Wiring diagram 3 Rocher DET spare part list 4 ROHS Images and tables Image 1 Recommended sauna room ventilation Image 2 Preparing for piling the stones Image 3 Installing the support for heating elements Image 4 Location for the connection box Image 5 Corner and wall installation Image 6 Middle installation Image Principle istallation Image 8 Wiring diagram for the sauna heater Table 1 Safety clearances Table 2 Connection cable and
9. ments may extend the pre heating period even though the sauna room is otherwise well insulated see page 6 section 2 7 Preparing for sauna heater installation Installation and User Manual ROCHER DET 4 2 2 Recommended sauna room ventilation j B lll v HHH 6 AAAA No Rf uf Nr AF FE aA NE Image 1 Recommended sauna room ventilation 1 Sauna room 3 Electric sauna heater 5 Exhaust flue or channel 2 Washroom 4 Exhaust valve 6 Door to the sauna room 7 A ventilation valve can be installed here to be kept closed while the sauna is heated and during bathing Inlet vent can be positioned in the A zone Make sure the incoming fresh air will not interfere with i e cool down the sauna heater s thermostat near the ceiling The B zone serves as the incoming air zone if the sauna room isn t fitted with forced ventilation In this case the exhaust valve is installed min 1m higher than the inlet valve DO NOT ISTALL INLET VALVE WITHIN ZONE C IF THE SAUNA HEATER S CONTROL THERMOSTAT IS LOCATED IN THE SAME ZONE 2 3 Heating the sauna Before turning the sauna heater on make sure the sauna room is suitable for taking a sauna bath When heated for the first time the sauna heater may emit some odour If you detect any odour while the sauna heater warms up disconnect the sauna heater briefly and air the room Then you can turn the sauna heater on again The sauna heater is turned on from the control panel that has controls for the hea
10. odukt der Gebrauchsanleitung oder der Verpackung weist darauf hin Die Werkstoffe sind gem ihrer Kennzeichnung wiederverwertbar Mit der Wiederverwendung der stofflichen Verwertung oder anderen Formen der Verwertung von Altger ten leisten Sie einen wichtigen Beitrag zum Schutze unserer Umwelt Dieses Produkt sollohne Steine und Specksteinmantel an dem Sammelpunkt f r Recycling zur ckgebracht werden Bitte erfragen Sie bei der Gemeindeverwaltung die zust ndige Entsorgungsstelle
11. ort bars Install the support bars as above in the reversed order Pile the stones so that they cover the heating elements For specific instructions refer to section 2 4 Sauna heater stones Image 2 Installation and User Manual ROCHER DET 2 10 Installing the support for heating elements Note that heating element support should always be used in order to prevent the heating elements from being bent into each other or out sideways Installation of the heating element support Pile in stones up to halfway of the provided space Position the support so that the heating elements stay between the openings Tilt the support and press the pivots at each end of the support to the grooves in the inside of the heater s vertical beams one end at a time The support for heating elements should stay levelled Push the pivots at one end of the support to the grooves in the vertical beams Press the pivots at the other end of the support to the grooves in the heater s vertical beams Subsequently pile in stones up to the upper edge so that they cover the heating elements Image 3 Installation and User Manual ROCHER DET 2 11 Sauna heater safety clearances Sewer Saunaroom Safety clearances min Adequate ee o of stones C T Oo D s x 98 s3 6 EE C gt T oO D EJ EILE 55 c Fre H A D F KW mm mm mm mm Approx kg m m 6 8 5 9 1900 60 60 770 100 10 5 9 15 1900 60 60 770 Table
12. ting temperature and time The heating of a sauna should be started roughly an hour before you plan to take a sauna bath so that the stones have time to heat up properly and the air warms up evenly in the sauna room Do not put any objects on the sauna heater Do not dry clothes on the sauna heater or anywhere in its vicinity Installation and User Manual ROCHER DET 5 2 4 Sauna heater stones Quality stones meet the following requirements Sauna stones should withstand heat and heat variation caused by vaporisation of the water thrown on the stones Stones should be rinsed before use in order to avoid odour and dust Sauna stones should have an uneven surface to supply a larger surface for the water to evaporate from Sauna stones should be large enough measuring about 50 100 mm to allow good ventilation between the stones This extends the useful life of the heating elements Sauna stones should be piled sparsely in order to enhance ventilation between the stones Do not bend the heating elements together or against the frame Rearrange the stones regularly at least once a year and replace small and broken stones with new larger stones Stones are piled so that they cover the heating elements Do not however pile a large heap of stones on the heating elements For a sufficient amount of stones refer to Table 1 on page 9 Any small stones in the package of stones must not be piled on the sauna heater The warr
13. truction manual or the package refers to this The materials can be recycled according to the markings on them By reusing utilising the materials or by otherwise reusing old equipment you make an important contribution for the protection of our environment Please note that the productis returned to the recycling centre without any sauna rocks and soapstone cover Please contact the municipal administration with enquiries concerning the recycling place Anvisningar f r milj skydd Denna produkt f r inte kastas med vanliga hush llssopor n r den inte l ngre anv nds Ist llet ska den levereras till en tervinningsplats f r elektriska och elektroniska apparater Symbolen p produkten handboken eller f rpackningen refererar till detta De olika materialen kan tervinnas enligt m rkningen p dem Genom att teranv nda nyttja materialen eller p annat s tt teranv nda utsliten utrustning bidrar du till att skydda v r milj Produkten returneras till tervinningscentralen utan bastusten och eventuell t ljstensmantel V nligen kontakta de kommunala myndighetema f r att ta reda p var du hittar n rmaste atervinningsplats Hinweise zum Umweltschutz Dieses Produkt darf am Ende seiner Lebens Dauer nicht ber den normalen Haushaltsabfall Entsorgt werden sondern muss an einem Sammelpunkt f r das Recycling von elektrischen und elektronischen Ger ten abgegeben werden Das Symbol auf dem pr
Download Pdf Manuals
Related Search
Related Contents
Linksys USB100H1 User's Manual Samsung GT-I9003/M4 Manual de utilizare(Froyo ver.) Graco Inc. 309412F Paint Sprayer User Manual AXIS M11 Series Installation Guide POWERPOD 410 MultiSite Suite: General Ledger User`s Manual Neutralizador de ácidos para aceites frigoríficos minerales Betriebsanleitung Gas-Infrarot-Dunkelstrahler infraSchwank D 取扱説明書 Copyright © All rights reserved.