User manual Fire alarm system EBL128 EBL128

image

Contents

1. Y Scroll or press 4 to menu H4 Press A to sub menu U1 Press A L This is a list in which you can scroll Press Return P9 to menu U1 C return Scroll to another menu or press Return to menu H4 Scroll to another menu or leave the menu system by pressing Return Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 7 2 Disablement by time channel U2 Only disablements by time channel will be displayed in menu U2 Other disablements will be displayed in menu U1 If the list is empty List is empty will be shown The LED Disablements L8 is indicating one or more disablements in the system and depending on the type of disablements also the LEDs Fault Disablements Alarm devices L13 and or Fire brigade tx L15 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 4 to menu H4 Press A to sub menu U1 Scroll or press 2 to menu U2 Press A L This is a list in which you can scroll Press Return P9 to menu U2 aum Scroll to another menu or press Return to menu H4 Scroll to another menu or leave the menu system by pressing Return 23 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 7 3 Sensor values U3 NOTE The Performance factor and the Min and Max values are upd
2. chapter Service signal Menu U4 is a list of the sensor s activating service signal which is an information only These sensor s have to be replaced Contact Service personnel The service signal has to be acknowledged in conjuction with the replacement but this can only be done by users with access level type Service personnel If there are no sensors activating service signal List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 4 to menu H4 Press A to sub menu U1 scroll or press 4 to menu U4 Press A L This is a list in which you can scroll Press Return P9 to menu U4 __ sun Scroll to another menu or press Return to menu H4 Scroll to another menu or leave the menu system by pressing Return 25 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 7 5 Technical warning U5 One or more Technical warnings in the system are indicated in the display with i Menu U5 is a list of the Technical warnings in the system If there are no Technical warnings List is empty will be shown Oo Log in with a User name and Password for typ Building officer or Service personnel see page 5 ap Scroll or press 4 to menu H4 Press A to sub menu U1 scroll or press 5 to menu US Press A T
3. EBL128 version 2 0 x Daily user s manual 10 2 Activate interlocking output C2 Not available for users with access level type Information only The output in each interlocking combination Area Point can be manually activated via this menu C2 The corresponding interlocking input will be monitored in the same way as if the output was activated by its control expression Reset of the output activated via menu C2 has to be performed via menu C3 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 9 to menu H9 Press A to sub menu Cl Scroll or press 2 to menu C2 Press A Use the keypad to specify Area Point AA and PP for the interlocking output to be activated Press A Interlocking output AA PP activated return Press A If more interlocking outputs shall be activated do as above if not press Return to menu C2 Scroll to another menu or press Return to menu H9 Scroll to another menu or leave the menu system by pressing Return 32 Panasonic Eco Solutions Nordic AB MEW01624 Rev 10 3 EBL128 version 2 0 x Daily user s manual Reset interlocking output C3 Not available for users with access level type Information only Interlocking output activated via its control expression and with latching output selected in EBLWin The output has to be reset via this menu C3 In
4. H3 Set calendar and clock H4 Present system status U1 Disablement U2 Disablement by time channel U3 Sensor values U4 Sensors activating SERVICE signal U5 Technical warning U6 Event log U7 Version and alarm counter H6 FAULT Acknowledge H7 Perform ZONE TEST H9 Interlocking outputs and inputs C1 Activated interlocking outputs inputs C2 Activate interlocking output C3 Reset interlocking output C4 Disable interlocking output C5 Re enable interlocking output H10 Change password Only the Password for the User name that was used for log on to the control unit can be changed Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual Service personnel Same as Building officer but also the following menus H5 Service A1 Calibration of superviced outputs A2 Sensitive fault detection mode A3 Service mode for COM loop A4 Display current consumption in unit A5 Display current consumption on COM loop A6 Display statistics for COM loop A7 Activate address setting mode for DU A8 Show information about site specific data H8 Maintenance S1 Disconnect Re connect COM loop S2 Disconnect Re connect zone line input S3 Disconnect Re connect addressable zone interface input S4 Acknowledge SERVICE signal S5 Restore weekly average to default S6 Test of alarm devices S7 Safe shut down of control unit S8 Activate zone address in alarm mode S9 Activate output S10 Reset activated o
5. S1 Default programmed as type Alarm device i e cannot be individually disabled 2 C i e output RO Default programmed as type Routing equipment Fire brigade tx i e can in that case also be disabled via menu B10 3 C i e expansion board 4581 or 4583 output Press A 6 Depending on the selected type use the keypad to type additional data 0 Output number 0 2 and COM loop technical address 1 Output S number 0 1 2 Output R number 0 3 Output number 0 7 and expansion board number 0 3 Press A Disabled or not disabled output information is shown Press A When required disable more outputs or press Return to menu B3 Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return Regarding the units 3377 4477 and 3379 Output number 0 high priority 1 medium priority and 2 low priority 12 Panasonic Eco Solutions Nordic AB MEW01624 Rev 5 4 EBL128 version 2 0 x Daily user s manual Disable all control ventilation exting or interlocking outputs B4 Not available for users with access level type Information only Outputs programmed as type Control general type Fire ventilation type Extinguishing system and type Interlocking can for the type respectively be collectively disabled all at the same time via menu B4 Disabled output will stay in or return to the normal condition for the output respective
6. device as well as the COM loop units 3377 4477 3379 4380 and 4383 When all outputs of type Alarm devices have been disabled also the LED Fault Disablements Alarm devices L13 will be turned ON When all outputs of type Alarm devices have been re enabled the LED Fault Disablements Alarm devices L13 will be turned OFF NOTE This function for alarm devices is not the same as for push button Silence alarm devices P3 unless the option Button Silence alarm devices disables alarm devices is selected in EBLwin System properties This menu B9 has higher priority than the push button Silence alarm devices 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll or press 9 to menu B9 Press A Alarm devices in normal condition or Alarm devices disabled will be shown Press A The condition changes Press Return P9 to menu B9 _ sete Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 18 Panasonic Eco Solutions Nordic AB MEW01624 Rev 5 10 EBL128 version 2 0 x Daily user s manual Disable re enable outputs for routing equipment B10 Not available for users with access level type Information only Disabled outputs for routing equipment are liste
7. page 5 ap Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll or press 2 to menu B2 Press A Use the keypad to type the zone number 01 99 and the address 01 99 Press A The alarm point can be automatically re enabled If automatic re enabling shall not be used press A Go to If automatic re enabling shall be used press 1 and use the keypad to set the time Press A C meum The alarm point zone address is disabled Press A When required disable more alarm points or press Return to menu B2 Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 11 Panasonic Eco Solutions Nordic AB MEW01624 Rev 5 3 EBL128 version 2 0 x Daily user s manual Disable output B3 Not available for users with access level type Information only Up to 100 control outputs except outputs of type alarm device can be individually disabled via menu B3 Disabled output will stay in or return to the normal condition for the output respectively 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 2 to menu H2 Press A to sub menu B1 scroll or press 3 to menu B3 Press A Use the keypad to select type of output 0 Loop unit 3361 3364 3377 4477 3379 4380 or 4383 output 1 C i e output SO or
8. user s manual 3 Log on to the Control Unit c i e User name Up to ten 10 User names 0 1 2 9 might be programmed Default are three User names available 0 1 and 2 but they might have been changed and or User names 3 9 might have been added during the commissioning of the system User name examples 0 Information only 1 Building officer 2 Service personnel 3 Mr Xxxxxxxxx 4 Miss Yyyyyyyyy etc Password Each User name has a Password that gives access to a user level type i e Information only Building officer or Service personnel User levels access level types Information only Building officer Service personnel Access to menus according to the following pages How to log in __ Access Press the button Access P8 With the keypad select 0 1 2 8 or 9 for a User name Or use gt to scroll through the available User names Press A to accept Type the Password for that User name Six digits For the default 0 Information only is no Password required After typing a correct Password main menu H1 or H4 depending on the user level will be visible Press A to accept scroll with 1 and or do a quick jump to the wanted main menu Press A to accept a jump to the first sub menu e g from menu H4 to U1 gt E g in menu H1 press 6 for a quick jump to menu H6 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 versio
9. Author Jan Pettersson Panasonic User manual MEW01624 Fire alarm system EBL128 E ire EBL128 version 2 0 x Daily user s manual Date of issue 2013 10 18 Date of rev This page has deliberately been left blank Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual Table of contents 1 Introduction 3 2 Front 4 3 Log on to the Control Unit c i e 5 4 Perform monthly test H1 9 5 Disable or re enable H2 10 5 1 Disable zone B1 10 5 2 Disable zone address B2 11 5 3 Disable output B3 12 5 4 Disable all control ventilation exting or interlocking outputs B4 13 5 5 Re enable zone B5 14 5 6 Re enable zone address B6 15 5 7 Re enable output B7 16 5 8 Re enable all control ventilation exting or interlocking outputs B8 17 5 9 Disable re enable alarm devices B9 18 5 10 Disable re enable outputs for routing equipment B10 19 5 11 Disable re enable alert annunciation function B11 20 6 Set calendar and clock H3 21 7 Present system status H4 22 7 1 Disablement U1 22 Lid Disablement by time channel U2 23 73 Sensor values U3 24 1 4 Sensors activating SERVICE signal U4 25 TS Technical warning U5 26 7 6 Event log U6 27 7 7 Version and alarm counter U7 28 8 FAULT Acknowledge H6 29 9 Perform ZONE TEST H7 30 10 Interlocking outputs and inputs H9 31 10 1 Activated interlocking outputs inputs C1 31 10 2 Activate interlocking
10. BS Press A L This is a list in which you can scroll Select a zone To re enable the selected zone press A C return When required re enable more zones or press Return P9 to menu B5 Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 14 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 5 6 Re enable zone address B6 Not available for users with access level type Information only Disabled alarm points zone address are listed in menu H4 U1 Re enabling via this menu has higher priority than automatic re enabling Alarm points zones disabled via the Encapsulation function have to be re enabled via this menu B6 before they can activate a new alarm In this case a zone will be presented as ZZ 00 ZZ 01 99 If there is nothing to re enable List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 D Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll or press 6 to menu B6 Press A L This is a list in which you can scroll Select an alarm point zone address To re enable the selected alarm point press A C etun When required re enable more alarm points or press Return P9 to menu B6 Scroll to another menu or press Return to menu
11. H2 Scroll to another menu or leave the menu system by pressing Return 15 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 5 7 Re enable output B7 Not available for users with access level type Information only Disabled outputs are listed in menu H4 U1 If there is nothing to re enable List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 ap Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll or press 7 to menu B7 Press A Only disabled types will be shown Use the keypad to select type of output 0 Loop unit 3361 3364 3377 4477 3379 4380 or 4383 output 1 C i e output SO or S1 Default programmed as type Alarm device i e cannot be individually disabled 2 C i e output RO Default programmed as type Routing equipment Fire brigade tx i e can in that case also be disabled via menu B10 3 C i e expansion board 4581 or 4583 output Press A L This is a list in which you can scroll Select the output to re enable press A When required re enable more outputs or press Return P9 until C menu B7 is shown Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 16 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 versio
12. amps for fire alarms faults etc will be correct NOTE The RTC component has no built in battery i e if EBL128 has been powerless no mains and no battery backup and after software download the date day of the week and the time have to be set when EBL128 is powered up again 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 3 to menu H3 Press A Use the keypad to set the date time and weekday Step right left with the arrow keys If the changes shall be saved press A if not press Return P9 to menu H3 C Scroll to another menu or leave the menu system by pressing Return Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 7 Present system status H4 7 1 Disablement U1 A list of all disablements done via menu H2 Bx Also alarm points that have been automatically disabled encupsulated in conjunction with fire alarm reset NOTE Disablements by time channel s are listed in menu H4 U2 If the list is empty List is empty will be shown The LED Disablements L8 is indicating one or more disablements in the system and depending on the type of disablements also the LEDs Fault Disablements Alarm devices L13 and or Fire brigade tx L15 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5
13. ated at midnight i e the values are from the previous day If the week average sensor value Weekly is 00 0 m check again approx 2 minutes later If the list is empty List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 ap Scroll or press 4 to menu H4 Press A to sub menu U1 Scroll or press 3 to menu U3 Press A Use the keypad to specify the Start sensor The default zone address 00 00 can be used Press A This is a list in which you can scroll Depending on if it is a heat smoke or multi detector the information is different For a gt multi detector use gt for more information After the last detector sensor No more sensors found in the system will be shown reum Press Return P9 two times to menu U3 Scroll to another menu or press Return to menu H4 Scroll to another menu or leave the menu system by pressing Return The information is described in EBL128 Operating Instructions MEWO01623 24 Panasonic Eco Solutions Nordic AB MEW01624 Rev 7 4 EBL128 version 2 0 x Daily user s manual Sensors activating SERVICE signal U4 Service signal is indicated by LED Service L12 The week average sensor value is over the service level respectively for one or more detectors sensors Regarding the service signal levels see Planning Instructions
14. d edited via this program User levels 1 2A 2 B and 2C according to EN54 2 The menus available are depending on the user level type for the user respectively see chapter Log on to the Control Unit c i e page 4 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 2 Front L1 L2 L3 gt Extinguishing GBD Silence buzzer L4 gt Ventilation Alarms queued Bert eevee L5 gt Fire brigade tx Reset L6 gt Operation Evacuate L7 10 L11 12 L13 14 L15 16 Front upper dark grey part Fire Brigade Panel FBP Front lower light grey part Information LEDs buttons and keypad L1 L16 and P1 P9 refer also to the Operating Instructions MEW01623 Keypad Use the arrow keys 4 4 v gt to step in the menu lists and in the selected menu respectively A quick jump to a menu can be done by pressing the corresponding digit key e g 6 for menu H6 Press A to accept select Press Return P9 to stop the enting of data and to C return jump one step upwards in the menu system e g from a sub menu to a main menu You will normally get some information that the action operation you wanted is performed e g Output xx disabled If not the information will be Operation failed Also e g if you try to disable a unit that doesn t exists in the installation Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily
15. d in menu H4 U1 Outputs for routing equipment fire brigade tx fault tx can be disabled and re enabled via this menu B10 Disabled output will stay disabled until re enabled again via this menu Can be useful during an installation and test period when only local alarms are required Disabled output for routing equipment is also indicated by LED Fault Disablements Fire brigade tx L15 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 2 to menu H2 Press A to sub menu B1 scroll or press 0 to menu B10 Press A The actual status for the output FIRE and FAULT respectively will be shown Use the keypad to select 1 enabled or O disabled for the output respectively Step right left with the arrow keys Press A The new status for the output FIRE and FAULT respectively will be shown Press A and Return P9 to menu B10 ee Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 19 Panasonic Eco Solutions Nordic AB MEWO01624 5 11 Rev EBL128 version 2 0 x Daily user s manual Disable re enable alert annunciation function B11 Not available for users with access level type Information only Normal operation For alarm points zones programmed for Alert Annunciation via EBLWin is normally the AA
16. eturn 27 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 7 7 Version and alarm counter U7 Version The EBL128 software firmware version Alarm counter The alarm counter is increased with 1 every time the c i e enters the real fire alarm condition Fire alarm indication in the display LEDs Fire lit and the c i e buzzer sounding i e not for zones in test mode It starts on 000 and goes to 999 It can be reset to 000 via EBLWin Control unit menu Reset alarm counter It is stored in an EEPROM i e the value will be retained also after the c i e has been powerless 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 4 to menu H4 Press A to sub menu U1 Scroll or press 7 to menu U7 Press A Version and Alarm counter is shown reum Press Return P9 to menu U7 Scroll to another menu or press Return to menu H4 Scroll to another menu or leave the menu system by pressing Return 28 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 8 FAULT Acknowledge H6 Users with access level type Information only can only see the fault messages not acknowledge the faults LED General fault L7 is indicating that not all faults are acknowledged and or corrected LED Fault tx activated L11 is indica
17. function enabled via a time channel e g enabled daytime during working hours and disabled night time As an alternative the AA function can be continuously enabled Turned Off Via this menu B11 it is possible to disable the AA function i e the AA function will be disabled for the alarm points zones programmed for Alert Annunciation in spite of the time channel is on or if they are programmed to be continuously enabled The AA function will stay disabled until re enabled again via this menu NOTE Disabled Alert Annunciation function is indicated by LED Fault Disablements Fire brigade tx delay L16 turned off 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll to menu B11 Press A Alert annunciation function is in normal operation or Alert annunciation function turned off will be shown Press A The status changes Press Return P9 to menu B11 _ eum Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 20 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 6 Set calendar and clock H3 Not available for users with access level type Information only When required the clock can be corrected so that the time st
18. g one or more disabled interlocking outputs 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 9 to menu H9 Press A to sub menu Cl Scroll or press 4 to menu C4 Press A Use the keypad to specify Area Point AA and PP for the interlocking output to be disabled Press A Interlocking output AA PP disabled Press A If more interlocking outputs shall be activated do as above if not press Return to menu C4 Scroll to another menu or press Return to menu H9 Scroll to another menu or leave the menu system by pressing Return 34 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 10 5 Re enable interlocking output C5 Not available for users with access level type Information only Disabled interlocking outputs are listed in menu H4 U1 Individually disabled interlocking outputs Type Interlocking have to be re enabled via this menu C5 All interlocking outputs disabled via menu _H2 B4 has to be re enabled via menu H2 B8 If there are no interlocking outputs to re enable List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 9 to menu H9 Press A to sub menu Cl Scroll or press 5 to menu C5 Press A This is a li
19. his is a list in which you can scroll Press Return P9 to menu US C Scroll to another menu or press Return to menu H4 Scroll to another menu or leave the menu system by pressing Return 26 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 7 6 Event log U6 Presentation of the events in EBL128 is divided into three event lists Alarm Interlocking and General respectively The event lists can also be read via EBLWin and the Web server II Each list can have up to 500 events The most recent event is shown in the top of the list The initials of the person logged on to the system e g JP will also be shown for each event when applicable i e for commands Commands done via EBLWin and the Web server will also be shown NOTE The event logging is disabled as long as this menu U6 is open 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 4 to menu H4 Press A to sub menu U1 Scroll or press 6 to menu U6 Press A Use the keypad to select event log 0 Alarm not control neutral 1 Interlocking 2 General Press A This is a list in which you can scroll Press Return P9 and select another event log or press Return again to menu U6 Scroll to another menu or press Return to menu H4 Scroll to another menu or leave the menu system by pressing R
20. ion 2 0 x Daily user s manual Perform ZONE TEST H7 me i G6 Not available for users with access level type Information only Normally zones are tested during the monthly test via menu H1 Via menu H7 it is possible to solely perform the zone test Up to 99 zones can be set in test mode which is indicated by the LED Test mode L9 In test mode only the alarm points are tested i e no outputs no sounders will be activated during the test except the fire door outputs Each test mode alarm will be automatically reset after approx 10 seconds If a real fire alarm is activated by an alarm point not in test mode the normal fire alarm functions will be activated i e fire alarm presentation outputs sounders activated routing equipment fire brigade tx activated etc but the zone s in test mode will remain in test mode until the test mode is ended There will be an automatic ending of the test mode one hour after the latest tested alarm point zone NOTE If the door in EBL128 is left open the output s for routing equipment fire brigade tx might be disabled if set so in EBLWin 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 7 to menu H7 Press A The sub menu Set zone in test mode D1 opens Press A Use the keypad to set one zone ZZ 01 99 in test mode Press A The zone ZZ is now in test mode Pre
21. ly 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll or press 4 to menu B4 Press A Use the keypad to select output type 0 Outputs type Control not control neutral 1 Outputs type Ventilation 2 Outputs type Extinguishing 3 Output type Interlocking Press A Disabled or not disabled output type information is shown Press A When required disable more output types or press Return to menu B4 Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 13 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 5 5 Re enable zone B5 Not available for users with access level type Information only Disabled zones are listed in menu H4 U1 Re enabling via menu B5 has higher priority than automatic re enabling NOTE Alarm points that have been individually disabled via menu H2 B2 cannot be collectively re enabled via menu B5 They have to be individually re enabled via menu H2 B6 If there is nothing to re enable List is empty will be shown Oo Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll or press 5 to menu
22. n 2 0 x Daily user s manual 5 8 C E Re enable all control ventilation exting or interlocking outputs B8 Not available for users with access level type Information only Disabled outputs are listed in menu H4 U1 If there is nothing to re enable List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 2 to menu H2 Press A to sub menu B1 Scroll or press 8 to menu B8 Press A Only disabled output types will be shown Use the keypad to select output type 0 Outputs type Control not control neutral 1 Outputs type Ventilation 2 Outputs type Extinguishing 3 Output type Interlocking Press A When required re enable more outputs or press Return P9 until menu B8 is shown Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 17 Panasonic Eco Solutions Nordic AB MEWO01624 Rev 5 9 EBL128 version 2 0 x Daily user s manual Disable re enable alarm devices B9 Not available for users with access level type Information only Disabled alarm devices are listed in menu H4 U1 Outputs for alarm devices can be collectively disabled and re enabled via this menu B9 Disabled output will stay disabled until re enabled again via this menu Alarm devices outputs programmed as type alarm
23. n 2 0 x Daily user s manual Log out You will be logged out when you close the door or 60 minutes after the last action i e if the key pad push buttons have not been used for 60 min If you leave the menu system but not close the door press Access P8 to open menu H1 directly i e log in is not required For the different user levels the following menus will be available Information only U1 Disablement U2 Disablement by time channel U3 Sensor values U4 Sensors activating SERVICE signal U5 Technical warning U6 Event log U7 Version and alarm counter H6 Display FAULTS No possibility to Acknowledge the faults H9 Interlocking outputs and inputs Only sub menu C1 available C1 Activated interlocking outputs inputs H10 Change password Only the Password for the User name that was used for log on to the control unit can be changed Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual Building officer Described in this document H2 Disable or re enable B1 Disable zone B2 Disable zone address B3 Disable output B4 Disable all control ventilation exting or interlocking outputs B5 Re enable zone B6 Re enable zone address B7 Re enable output B8 Re enable all control ventilation exting or interlocking outputs B9 Disable re enable alarm devices B10 Disable re enable outputs for routing equipment B11 Disable re enable alert annunciation function
24. nable H2 Not available for users with access level type Information only Any disablement in the system is indicated by the LED Disablements L8 5 1 Disable zone B1 All zones 01 99 can be individually disabled via menu B1 Normally all alarm points within the zone will be disabled except the addressable manual call points 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 2 to menu H2 Press A to sub menu B1 Press A Use the keypad to type the zone number 01 99 Press A The zone can be automatically re enabled If automatic re enabling shall not be used press A Go to 6 If automatic re enabling shall be used press 1 and use the keypad to set the time Press A C The zone is disabled Press A When required disable more zones or press Return to menu B1 Scroll to another menu or press Return to menu H2 Scroll to another menu or leave the menu system by pressing Return 10 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 5 2 Disable zone address B2 Not available for users with access level type Information only Up to 100 addressable alarm points zone address can be individually disabled via menu B2 Also addressable manual call points 1 Log in with a User name and Password for typ Building officer or Service personnel see
25. nasonic se acne rE ISO 9001 NATIONAL ACCREDITATION OFCERTIAOATION BODES
26. output C2 32 10 3 Reset interlocking output C3 33 10 4 Disable interlocking output C4 34 10 5 Re enable interlocking output C5 35 11 Change password H10 36 12 Revision history 37 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 1 Introduction This document is intended to be used for the daily duties like disablements re enablements zone tests etc in the EBL128 system The document describes the main menus incl the sub menus valid for user level type Building officer Due to continual development and improvement different S W versions can be found This document is valid for EBL128 S W version 2 0 x x 0 at the Date of issue or Date of revision This document is less detailed and shorter than the Operating Instruction MEW01623 NOTE In the left margin are pictures of the buttons keys used in the menu respectively Each picture is only shown one time in each menu not each time the button key should be used A User name and a Password is required to Log on to the control unit i e for access to the menu system NOTE In case of fire alarm activated in the system you have access to the special menus X1 X9 without any log on to the control unit The PC program EBLWin is used for commissioning etc User names and Passwords can be added an
27. ss A If more zones shall be set in testmode do like above if not press Return to menu D1 Perform the testing To end the test mode for one zone press The sub menu End zone in test mode D2 opens Press A L This is a list in which you can scroll Select the zone for wich the test mode shall be ended Press A The next zone in the list will be shown End the test mode like above After the last zone List is empty will be shown O Press Return to menu D2 OO Press Return to menu H7 Scroll to another menu or leave the menu system by pressing Return Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 10 Interlocking outputs and inputs H9 Each interlocking combination Area Point normally contains one interlocking output and one interlocking input 10 1 Activated interlocking outputs inputs C1 If there are no interlocking outputs inputs activated List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 9 to menu H9 Press A to sub menu Cl Press A This is a list in which you can scroll C reum Press Return P9 to menu C1 Scroll to another menu or press Return to menu H9 Scroll to another menu or leave the menu system by pressing Return Panasonic Eco Solutions Nordic AB MEW01624 Rev
28. st in which you can scroll Select the Area Point for the interlocking output to be re enabled Press A to re reum enable the output or press Return P9 to menu C5 Press A If more interlocking outputs shall be re enabled do as above if not press Return to menu C5 Scroll to another menu or press Return to menu H9 Scroll to another menu or leave the menu system by pressing Return 35 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 11 Change password H10 You can change the Password for the User name that was used for log on to the control unit An incorrect password will result in no change Y Scroll or press 0 to menu H10 Press A Use the keypad to enter the password that chall be changed the new password six digits and verify the new password Password is changed Press Return P9 to menu H10 Scroll to another menu or leave the menu system by pressing Return Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 12 Revision history 37 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 38 This page has deliberately been left blank Panasonic Panasonic Eco Solutions Nordic AB Jungmansgatan 12 SE 211 19 Malm Sweden Tel 46 0 40 697 70 00 Fax 46 0 40 697 70 99 info pesn eu panasonic com http pesn pa
29. terlocking output activated via its control expression and with latching output not selected The output can be reset via this menu C3 Interlocking output activated via menu C2 has to be reset via this menu C3 If there are no interlocking outputs to reset List is empty will be shown Oo Log in with a User name and Password for typ Building officer or Service personnel see page 5 Scroll or press 9 to menu H9 Press A to sub menu Cl Scroll or press 3 to menu C3 Press A This is a list in which you can scroll Select the Area C E Point for the interlocking output to be reset Press A to reset the output or press Return P9 to menu C3 Press A If more interlocking outputs shall be reset do as above if not press Return to menu C3 Scroll to another menu or press Return to menu H9 Scroll to another menu or leave the menu system by pressing Return 33 Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 10 4 Disable interlocking output C4 Not available for users with access level type Information only Up to 100 Interlocking outputs Type Interlocking can be individually disabled via this menu C4 but not via menu H2 All interlocking outputs can be collectively disabled via menu H2 B4 Disabled interlocking outputs are listed in menu H4 U1 The LED Disablements L8 is also indicatin
30. ting that the output for Fault condition routing equipment Fault tx is activated The LED will be turned off when all faults are acknowledged All faults are normally latched i e all faults have to be acknowledged All fault events are stored in the General event log and can be listed In this menu H6 are up to 200 faults listed e Not corrected and not acknowledged faults no status info e Not corrected but acknowledged faults status Acknowledged e Corrected but not acknowledged faults status Serviced If there are no faults List is empty will be shown 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 Y Scroll or press 6 to menu H6 Press A This is a list in which you can scroll The first fault in the list is the most recent fault Status info see above gt When applicable press gt for more info To acknowledge the fault shown in the display press Fault acknowledge P6 The status will change to Acknowledged if the fault is not corrected serviced If the fault is corrected serviced it will disappear from the list Press Return P9 to leave the list and go to menu H6 Scroll to another menu or leave the menu system by pressing Return 7 If faults are set via EBLWin to be Not latched Serviced will never be shown Panasonic Eco Solutions Nordic AB MEW01624 Rev 9 EBL128 vers
31. utput Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 4 Perform monthly test H1 Not available for users with access level type Information only Regarding the Test mode see 6 below see also page 30 1 Log in with a User name and Password for typ Building officer or Service personnel see page 5 6 Press A Check that all LEDs light up Press A The c i e buzzer sounds all the dots in the display are shown and all LEDs on the front are turned on Press A Up to four zones can be set in test mode Use the keypad to type the zone numbers Press A to start the test Perform the tests Press A to end the test If the routing equipment shall not be tested press A and the monthly test is completed Press A to menu H1 Go to below If the routing equipment shall be tested press 1 To start the test press A Started test is indicated by LED Fault tx activated L11 and after 30 seconds also LED Fire brigade tx L5 After 60 seconds in total the routing equipment test is ended and the LEDs are turned off The monthly test is completed Press A to menu H1 C reum Menu H1 is shown Scroll to another menu or leave the menu system by pressing Return P9 4 If a Fire brigade tx output is programmed Panasonic Eco Solutions Nordic AB MEW01624 Rev EBL128 version 2 0 x Daily user s manual 5 Disable or re e

Download Pdf Manuals

image

Related Search

Related Contents

Installing GFI MailEssentials  Viper S - LOOK Solutions  Emerson T208 Instruction Manual  DEFY Model DGS 150 150 User's Manual  MANUAL DO USUÁRIO  T。SH`BA 取扱説明書/ーNSTRUCT旧N MANUAL  Chapter 6 - AutomationDirect  Adobe Drive CC User Guide  Conduite et entretiena  Gebrauchsanweisung KL 200 LED Apr 11 spanisch  