1. Lab Gruppen is kept near the maximum value e g around 10 dB Thereafter the channels can be separately fine tuned with Lab Gruppen amplifier
2. ADU2a User Manual Control room DVD player NAD Power amplifier e Lab Gruppen Stimulus PC f Ai Optical connection hole ferrites units tubes j Safety Precautions It is important to make sure that the measurement subject is protected against any possible hearing damage Therefore one should always go by the following safety precautions 1 the noise of the scanner should be dampened by using double hearing protection earplugs eartips of the correct size please make sure that the plugs tips are properly inserted into the ear canal and external earmuffs which should fit tightly and cover the whole earlobe The effectiveness of the eartips should be beefed up with tufts of cotton wool the area volume inside the earlobe is filled with cotton wool Additional attenuation of the scanner noise can be achieved by installing sheets of Eterlon Formax FX 65S on both sides of the 8 channel EXCITE brain coil and by covering the orange tubes carrying the stimulus sounds to the eartips with a towel 2 The sound volume of the stimuli should not be too high One should start with very low volume level and if needed increase the level of volume with great care so that the sound level will never be too loud Also the subject should always be informed that he she must report immediately if the stimuli or the noise from the scanner feels unpleasantly loud The volume of the stimulus sound and thus the maximum SPL Sound Pressure L
3. amplification Second desired SPL over threshold is added However in a noisy environment such as the MR scanner room the hearing threshold is shifted upwards which should be taken into account when adjusting the volume The dB scale of the Denon amplifier is linear from 55 to 10 dB but user should only use volume range from 55dB to OdB because higher volumes may cause hearing defect One should make sure that both speakers A and B are switched off in the amplifier front panel in order to get the output to the ADU2a system 3 Audio System Selector Sound signal is lead from the amplifier front panel stereo headphones connector to an audio system selector and further to the audio stimulator systems In audio system selector there is a switch to select ADU2a stimulator 4 Power Amplifier Lab Gruppen The signal is led from the audio system selector to a Lab Gruppen iP 900 power amplifier Because the input resistance of the ADU2a transducer elements is 8 Q the maximum output power from the amplifier is 99 4 W The maximum power that the ADU2a elements can tolerate is 100 W The signal amplification is mainly adjusted from the Denon amplifier In that case the gain of the Lab Gruppen amplifier is kept at 0 dB However the gain of both left and right channels can be separately adjusted from the Lab Gruppen amplifier In this case the output SPL should be adjusted to a comfortable listening level with the Denon amplifier while the
4. evel of the whole sound system is dependent on the amplification set in the Denon and Lab Gruppen amplifiers recording level of the original sound signal and volume settings in the stimulus PC If you are uncertain of the correct procedures please contact AMI personnel for more information Equipment used for auditory stimulation in the AMI Centre ADU2a Stimulator The ADU2a stimulator consists of an electrodynamic transducer unit and 5 meters of silicon tube one set for each ear The transducer and related stimulator electronics are shielded in an aluminum box The sound is transmitted from the transducer as an acoustical signal through plastic and silicon tubes to the subject s ear using replaceable porous eartips at the end of the tubes In the tubes there are marks to indicate which tube is left right The transducer elements are protected with a thermal resistance to prevent the stimulator units from over heating due to excessive input power If the thermal resistance is activated it takes a while before the transducer units become functional again The researcher should not feed any signal to the stimulators until the thermal resistors have cooled down 1 Stimulus PC amp CD DVD player At AMI Centre the most commonly used sound source is stimulus PC Windows 98 SoundBlaster sound card From the stimulus PC soundcard the signal is led to a Denon AVR 1802 audio amplifier The connection between PC and amplifier is opt
5. ic to prevent the formation of humming sound caused by ground currents between the devices Another sound source connected to the Denon amplifier is a NAD CD DVD player Also the CD DVD player output is connected to the amplifier input optically The frequency response of the ADU2a stimulators is limited below 10 kHz Hence the stimuli should not contain frequencies above 10 kHz When a high frequency stimulus is played at high intensity the resulting sound has a nonlinear distortion and may even break the transducer elements Currently the frequency range of the stimuli have to be limited below 10 kHz before the signal is fed to the ADU2a stimulators 1 e when creating the stimuli but in the near future an analog low pass filter will be added to the ADU2a system To reach the maximum output volume of the ADU2a system the input signal must be recorded at the maximum level in the wave file and the PC volume settings should be at the maximum position 2 Denon Amplifier To use the sounds from the stimulus PC select the input marked as STIM PC in the front panel of the Denon amplifier For the NAD CD DVD player use the input marked as CD DVD You can also use the internal tuner of the Denon amplifier by selecting the input marked as RADIO The Denon amplifier can be used to define the sound pressure level with respect to individual hearing threshold First the hearing threshold is determined by adjusting the

Download Pdf Manuals

image

Related Search

Related Contents

2. Operation Guide    User Manual  Astro Romano 1200  2010.6月号 兵ト協ニュース287  LG WM3070HVA washing machine  User Manual - Pressure Care  議事録 - 国土交通省  Gruppo manuale OptiFlex S - parti di ricambio  INFOMEX-GOBIERNO FEDERAL  

Copyright © All rights reserved.
Failed to retrieve file