Home

USER'S MANUAL - ao

image

Contents

1. Blue wire of Main Unit to pin number 3 of 9 pin connector Connect RS 232 GND Yellow wire of Main Unit to pin number 5 of 9 pin connector Plug in 9 pin connector to COM1 or COM2 Port of Personal Computer Install and run STAR 100R PIN120 Application Software 9 10 Chime Bell Connection Separate purchase required Connect wire of Chime Bell unit to Bell Output Brown White wire of Main Unit Connect wire of Chime Bell unit to Power GND wire 10 IDTECA o PIN amp Proximity PINPAD IPASS P 100R Single Door Access Controller 10 Initial Setup The Flash memory of each shipped STAR 100R PIN120 contains a minimum set of defaulted values but it does not have any other preprogrammed values or user s data in it therefore Initial Setup is required upon the first time the unit is powered up in order to operate the unit properly 10 1 Registration of RF Cards for RF CARD ONLY MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 4 JEn from the keypad RF CARD ONLY MODE 3 Present RF Cards as follow to register Configuration Card and User Access Cards Configuration Card User Access Cards Configuration Card again to end task X NOTE The user may choose to register the 8 digit card numbers via the keypad instead of presenting the cards to the unit this implies that the user must know the 8 digit representatio
2. 03 sec Soe OW Configuration Card Command TTL time Configuration PIN 12 31 Test Door Open Time Set By Command 21 12 32 Test Alarm Time Set By Command 22 12 33 Test Alarm Time Set By Command 23 12 34 Test Alarm Time Set By Command 24 12 35 Test Alarm Time Set By Command 25 12 36 Test Alarm Time Set By Command 26 12 37 Test Alarm Time Set By Command 27 Outputs set by command will be tested ok Configuration Card Command Configuration PIN 12 39 Change Chime Bell Activating Time tt 00 99 sec Defaulted Chime Bell time 05 sec 3 0 fn Ct t ent Configuration Card Command Chime Bell time Configuration PIN 20 IDTECA pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 12 41 Open Door Unconditional configuration PIN OE 12 42 Close Door Unconditional configuration PIN CEE 12 43 Enable QUICK ACCESS MODE When QUICK ACCESS MODE is enabled Door will open simply by press Ent key Configuration Card Configuration PIN 4 3 Je 12 44 Disable QUICK ACCESS MODE Configuration Card Configuration PIN 4 4 ext Defaulted setting Disable 12 45 Enable Toggle Mode for Lock Control If you set Enable Toggle Mode Door will be toggled open and close function when the registered card or PIN entered You may use this function for Arm Disarm Configuration Card for buglar alarm system 12 46 Disable Toggle Mode for Lock Control Configuration C
3. 1 55 39 5mm 1 85 47mm wi Wi on Do 2 05 52mm 1 52 38 5mm 1 52 38 5mm 3 03 77mm 7 2 Using 2 screws install wall mount to the wall X CAUTIONS Before mounting the STAR 100R PIN120 unit to the Wall Mount bracket operational testing of the unit should be completed as the locking pins will lock the unit to the Wall Mount Removing the unit from the Wall Mount bracket after they have been installed together may cause damages to the bracket and render its effectiveness 7 3 Insert 5 O rings to the wall mount as indicated then route the cable of the main unit through the center hole and push the main unit to wall mount to lock the main unit and make sure that the main unit is locked with wall mount IDTECA tPASS P 100R 8 Color Coded and Wiring Table I O PORT NAME SIGNAL NAME POWER Main Power V 12V Power Ground OV OUTPUT Door RELAY 2A COM Door RELAY 2A NC Door RELAY 2A NO Alarm RELAY 2A COM Alarm RELAY 2A NC Alarm RELAY 2A NO TTL Output TTL CHIME BELL Output BELL INPUT Exit Button EXIT Door Sensor CONTACT Aux Input 1 IN 1 Aux Input 2 IN 2 Aux Input 3 IN 3 WIEGAND INPUT OUTPUT Wiegand Data 0 DATAO Wiegand Data 1 DATA RS 232 INTERFACE RS232 TX TXD RS232 RX RXD RS232 GND GND IDTECA PIN amp Proximity PINPAD Single Door Access Controller COLOR CODED Red wire Black wire Gray wire with Red band Blue wire with White band White wire with
4. 3 Registration of PIN ONLY MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press 0 3 Jn from the keypad PIN ONLY MODE 3 Enter to register Configuration PIN then to register for each subsequent User Access PIN at a time and then enter the Configuration PIN to complete the registration KO Configuration PIN User Access PIN Configuration PIN again to complete the registration 4 The first 4 6 digit PIN becomes the Configuration PIN and the subsequent 4 6 digit PINs are registered as User Access PINs Once all User Access PINs have been registered enter the Configuration PIN again to complete the registration Please store the Configuration PIN for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 4 Registration of RF PIN Combination MODE 1 Apply 12V DC to the unit All 3 LEDs will be flashing with a power up melody Press 0 5 e from the keypad RF PIN Combination Mode Present Configuration Card to register Configuration Card to the unit Present RF Card or enter 4 6 digit PIN number to register user access card or PIN Present Configuration Card to complete the registration 2 3 4 5 Na eer No Hy Configuration Card or or or Configuration Card PIN PIN PIN 10 5 Factory Defaulted Setting Values After the Initial Setup the Main Unit use
5. Card Reading m Engineer Write problem must be Input Output o Keypad o RS 422 Com o Comment detailed Others g others S RS 232 Com o Power o Card Reading o Input Output o Keypad o RS 422 Com o Engineer Comment Others o Po RS 232 Com Power o Card Reading o Engineer Input Output o Keypad o RS 422 Com o Comment Others o RS 232 Com o Power o Card Reading o Input Output o Keypad o RS 422 Com o alll Otheso OC lo Ea a Cee Power o Engineer Input Output o Keypad o RS 422 Com o Comment Others o Manufacturer s Verification Product Defective Installation Error User s Misuse Connection Error Communication Error Others Packing Details Dimension L W H 30 25 80 No of Units 20 Net amp Gross Weight 150g No of Boxes 2 Requested by Received by XXXX YYYY Signature of Buyer Signature of IDTECK 29 IDTECX pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 16 Warranty and Service The following warranty and service information applies only to the United States of America and Republic of Korea For the information in other countries please contact your local distributor To obtain in or out of warranty service please prepay shipment and return the unit to the appropriate facility listed below IN THE UNITED STATES RF LOGICS Inc Service Center Headquarters and Western Region 370 Amapola Ave 106 Torrance CA 90501 Tel 310 782 8383 Fax 310
6. Door time Alarm Time TTL time Configuration PIN 12 23 Change Alarm Time When Try Out Error Detected Refer to Table 1 for OM 14 00 99 sec Defaulted Alarm time 10 sec DOT Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 24 Change Alarm Time When Door Contact Error Detected Refer to Table 1 for OM tt 00 99 sec Door Open Time out setting is required for activating refer to 12 81 DOM Ome Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 25 Change Alarm Time When AUX Input 1 Detected 12 26 Change Alarm Time When AUX Input 2 Detected 12 27 Change Alarm Time When AUX Input 3 Detected Refer to Table 1 for OM tt 00 99 sec o oHm Cos 21177 VENT Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 12 28 Change Alarm Time When Magnet Detected Refer to Table 1 for OM tt 00 99 sec o mEn DOM HE Configuration Card Command Output Mode Door time Alarm Time TTL time Configuration PIN 19 IDTECX pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 12 29 Register 2 Digit Duress Alarm Password ah PW 00 99 Defaulted PW 00 Do not use Ze wes Configuration Card Command Password Configuration PIN Note 00 is registered as defaulted Password 12 30 Change Alarm Time When Duress Alarm Detected tt 00 99 sec Defaulted TTL time
7. Red band White wire Purple wire with White band Purple wire Orange wire with White band Brown wire with White band Yellow wire with Red band Green wire Orange wire Green wire with White band Brown wire Pink wire Cyan wire Grey wire Blue wire Yellow wire o PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 9 System Wiring for Typical Application EXIT riii la EXT L BUTTON _ CONTACT id DOON ng CONTACT PIA SENSOR ALUX INET CHIAE j CHIME MELI DU 12Y SUPPLY 9 1 Power Connection Connect wire of DC 12V power to Red wire and Red White banded wire Connect Power GND wire of DC 12V to Black wire and Black White banded wire 9 2 Door Lock Connection 9 2 1 Connection of POWER FAIL SAFE Door Lock Connect Door RELAY NC Blue White banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY COM Grey Red banded wire Connect wire of Door Lock to Power GND wire 9 2 2 Connection of POWER FAIL SECURE Door Lock Connect Door RELAY COM Grey Red banded wire to DC 12V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Door Lock to Door RELAY NO White Red banded wire Connect wire of
8. gt SETTINGS FOR COMMAND You must add value and Setting value for activating time Activate Mode Activate only in Secure Mode Activate in Safe amp Secure Mode Setting Value for activating Output Port Activate Output Port Activate only Door Relay Activate only Alarm Relay Activate only TTL Output Activate Door Relay amp TTL Activate Alarm Relay amp TTL ttis the activating time value seconds from 01sec to 99sec PW is the 2 digits Password for Duress Alarm MM is activating time value minutes from 01min to 99min Symbol Setting Values Examples Remarks EX1 Activate Door Relay In Safe amp Secure Mode Safe amp Secure Mode 50 Door Relay OL OM 51 EX2 Activate Alarm Relay amp TTL only in Secure mode Secure Mode OO Alarm Relay amp TTL 06 OM 06 tt value 00sec means no operation Do not use 77 for PW as itis used for Secure Mode mm value 00min means no operation 12 21 Change Door Open Time When User Access Card or PIN Is Granted i 46 00 99 sec Defaulted Door Open time 03 sec Configuration Card Command Door open time TTL time Configuration PIN 12 22 Change Alarm Time When User Access Card or PIN Is Denied Refer to Table 1 for OM tt 00 99 sec Defaulted Alarm time 02 sec 18 IDTECA pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller o ar eny Configuration Card Command Output Mode
9. time set by command 24 35 Test Alarm time set by command 25 36 Test Alarm time set by command 26 3 Test Alarm time set by command 27 39 Change Chime Bell activating time 41 Open door unconditionally 15 IDTECA PASS 42 43 44 15 45 46 47 48 51 52 60 61 62 63 64 65 66 67 68 69 70 11 12 ai 18 80 81 82 83 84 88 89 99 PIN amp Proximity PINPAD P 100R Single Door Access Controller Close door unconditionally Enable QUICK ACCESS MODE Disable QUICK ACCESS MODE Add User Access Card PIN RF PIN Combination Mode Enable Toggle Mode for Lock control Disable Toggle Mode for Lock control Enable Unlock followed by Door Contact Disable Unlock followed by Door Contact Disable Melody sound turning off both the melody amp keypress audio feedback Enable Melody sound Change keypad lock out time when Try Out error detected set Aux Input 1 Detection from L to H set Aux Input 1 Detection from H to L set Aux Input 2 Detection from L to H set Aux Input 2 Detection from H to L set Aux Input 3 Detection from L to H set Aux Input 3 Detection from H to L Set Exit Button Input Detection from L to H Set Exit Button Input Detection from H to L set Door Contact sensor Input Detection from L to H Set Door Contact sensor Input Detection from H to L Activate TTL output to H Activate TT
10. 782 8298 E mail rflogics rflogics com Web site www rflogics com OUTSIDE OF THE UNITED STATES IDTECK CO LTD Service Center 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu SEOUL 157 030 KOREA Tel 82 2 659 0055 Fax 82 2 659 0086 E mail webmaster idteck com Web site www idteck com Please use the original container or pack the unit s in a sturdy carton with sufficient packing to prevent damage include the following information 1 A proof of purchase indicating model number and date of purchase 2 Bill to address 3 Ship to address 4 Number and description of units shipped 5 Name and telephone number of person to contact 6 Reason for return and description of the problem NOTE Damage occuring during shipment is deemed the responsibility of the carrier and claims should be made directly to the carrier 30 IDTECA pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 17 Template 6 32 hole 31 IDTECA n PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller The specification contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com Copyright IDTECK Co Ltd
11. D blinking with beep sound indicates success of initialization 1 Main power off 2 Connect the orange and orange with white stripe wire together and power on 3 3 color LED blinking with beep sound indicates the success of initialization 100R Over V5 0 4 4 Disconnect those two wires and wire them as shown above normal connection diagram 100R V5 0 0 V5 0 3 4 Main power off again 5 Disconnect orange wire and orange with white stripe wire as shown above normal connection diagram and power on 26 IDTECA pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 14 FCC Registration Information FCC REQUIREMENTS PART 15 Caution Any changes or modifications in construction of this device which are not expressly approved by the manufacturer for compliance could void the user s authority to operate the equipment NOTE This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interface and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause
12. D is flashing every second When a registered Card or PIN is read the Door will open for 3 seconds along with the do mi sol do melody GLOSS Registered Card or PIN 13 IDTECA PIN amp Proximity PINPAD o PASS P 100R Single Door Access Controller 11 3 Exit Open the Door To request for exit from the inside an Exit Button can be used to open the door C for the same duration as in 11 2 MELZ S Ext Button 11 4 Action and Alarm Caused by Unregistered Card or PIN When an unregistered Card or PIN is read thus access is denied and the Alarm can be activated for 2 seconds along with sol do sol do melody GB Unregistered Card or PIN If you do not want to activate the Alarm in case of unregistered access attempt then you can change this setting as shown in section 12 11 5 Secure Mode The last person to exit can change the operation of the unit from Normal Mode to Secure Mode by entering the Secure Code of onto the keypad gt Change to Secure Mode The Secure Mode will revert back to the normal mode when a registered card or PIN is presented lentered 11 6 DURESS Alarm In case of Duress enter the 2 digit Duress Password P w fem and the door will open as usual however the Duress Alarm TTL Output will activate an external Auto Dialer to notify the appropriate personnel See section 9 7 and 12 29 for more instructions on this feature 11 7 Chime Bell Operati
13. Door Lock to Power GND wire IDTECA o PIN amp Proximity PINPAD APASS P 100R Single Door Access Controller 9 3 Alarm Device Connection Connect Alarm RELAY COM White wire to DC 412V be sure that the existing power supply has enough capacity to support this accessory or upgrade to a sufficient one Connect wire of Alarm Device to Alarm RELAY NO Purple wire Connect wire of Alarm Device to Power GND wire 9 4 Exit Button Connection Connect one of the wires of Exit Button to Exit Button Input Yellow Red banded wire Connect the other wire of Exit Button to Power GND wire If a normally closed Exit button is used then see section 12 67 to change the detection scheme from the defaulted setting 9 5 Door Contact Sensor Connection Connect Door Contact sensor COM wire to Door Contact Input Green wire Connect Door Contact sensor NO wire to Power GND wire If a normally closed Door Contact sensor is used then see section 12 69 to change the detection scheme from the defaulted setting 9 6 Auxiliary Input Device Connection Applied to AUX Input 1 2 3 Connect one wire of the Auxiliary Input Device to the AUX Input wire Input 1 Orange Input 2 Green White banded Input 3 Brown wire Connect the other wire of Auxiliary Input Device to Power GND wire If a normally closed input device is used then see section 12 61 63 amp 65 to change the detection schemes from the
14. L output to L Enable Chime Bell Output Disable Chime Bell Output Set delay time to activate SECURE MODE set Door Open time out for Door Contact sensor set number of times of Try Out Set input key press time out time set Tamper Alarm output port Enable Tamper Alarm Disable Tamper Alarm Re Initialize and erase all setup data 12 11 Add User Access Cards RF CARD ONLY MODE A A oo Configuration Card Command Cards to be registered Configuration Card IDTECA 16 APASS P 100R 12 12 Add User Access Cards RF CARD PIN MODE Aa A ENT a Configuration Card Command 12 13 Add User Access PIN PIN ONLY MODE Configuration PIN 4 b digit PIN Command PINs to be registered Cards to be registered PIN amp Proximity PINPAD Single Door Access Controller Configuration Card Anas 4 6 digit PIN Configuration PIN 12 14 1 Delete User Access Cards RF CARD ONLY MODE amp RF CARD PIN MODE nos 4 a Configuration Card Command Cards to be deleted 12 14 2 Delete User Access PIN PIN ONLY MODE nag Configuration PIN 4 b digit PIN Command PINs to be deleted 12 15 Add User Access Card PIN RF PIN Combination Mode ap 2 B Or Or Configuration Card Command PIN PIN IDTECA 17 4 6 digit PIN Configuration PIN Configuration Card PIN amp Proximity PINPAD Single Door Access Controller APASS P 100R lt TABLE 1
15. ard 12 47 Enable Lock followed by Door Contact If you set Enable Lock followed by Door Contact Door only be locked followed by Door Contact so the door will remain open until the door is completely closed Configuration Card 21 IDTECA pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 12 48 Disable Lock followed by Door Contact Configuration Card 12 51 Disable Melody Sound Configuration Card Configuration PIN 12 52 Enable Melody Sound Configuration Card Configuration PIN Defaulted setting E nable 12 60 Change Keypad Lock out Time When Try Out Error Detected MM 00 99 min Defaulted Keypad Lock out time 01 min 6 0 Enr mi m fen Configuration Card Command Keypad Lock out time Configuration PIN 12 61 Set AUX Input 1 Detection from L to H AUX 1 input is detected on the raising edge of AUX 1 input Configuration Card Configuration PIN 6 4 JEn 12 62 Set AUX Input 1 Detection from H to L AUX 1 input is detected on the falling edge of AUX 1 input Defaulted setting Configuration Card Configuration PIN 6 2 JEn 12 63 Set AUX 2 Input Detection from L to H AUX 2 input is detected on the raising edge of AUX 2 input Configuration Card Configuration PIN 6 3 Jenn 12 64 Set AUX 2 Input Detection from H to L AUX 2 input is detected on the falling edge of AUX 2 input Defaulted setting Confi
16. defaulted settings 9 7 Auto Dialer Connection Separate purchase required The Auto dialer function of this unit has not been evaluated by UL Connect the input wire of Auto Dialer to TTL output Orange White banded wire Connect wire of Auto Dialer to DC 12V be sure that the existing power supply has enough Capacity to support this accessory or upgrade to a sufficient one Connect wire of Auto Dialer to Power GND wire Connect Telephone Line plug RJ 14 to Auto Dialer If an active High Auto Dialer is used then see section 12 71 to change the TTL output level from the defaulted setting 9 8 Wiegand Input Connection From Another Compatible Wiegand Reader Separate purchase required Connect wire of Reader to DC 12V be sure that the existing power supply has enough Capacity to support this accessory or upgrade to a sufficient one Connect wire of Reader to Power GND wire Connect Wiegand output DATAO wire of the additional Reader to DATAO Pink wire IDTECA 9 PIN amp Proximity PINPAD o PASS P 100R Single Door Access Controller Connect Wiegand output DATA1 wire of the additional Reader to DATA1 Cyan wire 9 9 RS 232 Communication Port Connection 9 pin connector COM Port female is required to connect serial communication RS 232 between Main Unit and Personal Computer Connect RS 232 TX Grey wire of Main Unit to pin number 2 of 9 pin connector Connect RS 232 RX
17. er adjustment of other controls that are not covered by this manual may damage the unit and will often require extensive work by a qualified technician to restore normal operation d If the product exhibits a distinct change in performance 2 General A properly configured iPASS IP 100R is an intelligent single door controller that combines the convenience of wireless entry with the security of an alarm system Also the iPASS IP 100R system will give you field proven reliability and cost effective solution anywhere access controls and high security are required Each standard unit can store up to 128 users or card IDs a 512 user version is also available The task of assigning cards and managing a user s database is so simple user friendly and can be accomplished in many ways it could be as simple as presenting each card to the unit or as descriptive as a user s database with an easy to use Graphical User Interface The iPASS IP 100R can interface and operate with these accessories Request for EXIT button Door Contact sensor PIR sensor Fire sensor and other sensors via 5 independent input ports Also output ports which include 2 Relays and 2 TTL outputs can be used to control the operation of other accessories such as Electric Magnetic Door Lock Alarm Chime Bell and Auto Dialer Moreover the status or behaviors of these input and output accessories are configurable to provide the system administrator with complete customized control of t
18. er a Input Output o Keypad o RS 422 Com o Comment Others 0 ar 232 Com o Power o Card Reading o Engineer Input Output o Keypad o RS 422 Com o Comment Others 0 a 232 Com o Power o Card Reading o Ha Input Output o Keypad o RS 422 Com o Orso FP Card Reading o Engineer Input Output o Keypad o RS 422 Com o Manufacture s Verification Product Defective Installation Error User s Misuse Connection Error Communication Error Others Packing Details Dimension L W hH No of Units Net amp Gross Weight No of Boxes Comment Requested by Received by Signature of Buyer Signature of IDTECK IDTECK 28 pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller e RMA REQUEST FORM SAMPLE IDTECK Co Ltd ps ND casa point oF Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea TEL 82 2 2659 0055 FAX 82 2 2659 0086 www idteck com RMA REQUEST FORM Send to RMA No amp Date We will send this No if needed RMA Customer Service Original Invoice No amp Date 00 00 0 000 2005 10 01 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Requested from Seoul 157 030 Korea Mr XXXX YYYY Sales Person in Charge ABC Company Karina Kwak Address Country Shipping Port Narita Air Vessel Ar Departure Date 2005 10 15 Serial Number Error Check Box by Shipper SR 10 XXXXXXXXXXXXX RS 232 Com o Power ml
19. guration Card Configuration PIN 6 4 ent IDTECA 22 pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 12 65 Set AUX 3 Input Detection from L to H AUX 3 input is detected on the raising edge of AUX 3 input Configuration Card Configuration PIN 6 5 fn 12 66 Set AUX 3 Input Detection from H to L AUX 3 input is detected on the falling edge of AUX 3 input Defaulted setting Configuration Card Configuration PIN 6 6 JEn 12 67 Set Exit Button Input Detection from L to H Exit Button input is detected on the raising edge of Exit Button input Configuration Card Configuration PIN 6 _7 Enr 12 68 Set Exit Button Input Detection from H to L Exit Button input is detected on the falling edge of Exit Button input Defaulted setting Configuration Card Configuration PIN 6 8 JEn 12 69 Set Door Contact Sensor Input Detection from L to H Door Contact input is detected on the raising edge of Door Contact input Configuration Card Configuration PIN 6 9 ent 12 70 Set Door Contact Sensor Input Detection from H to L Door Contact input is detected on the falling edge of Door Contact input Defaulted setting Configuration Card Configuration PIN 7 0 JEn 12 71 Activate TTL Output to H TTL output changes the state from logic 0 to logic 1 when it activates Configuration Card Configuration PIN 12 72 Acti
20. harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the radio or television off and on the user is encouraged to try to correct interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on another circuit 4 Consult the dealer or an experienced radio TV technician for help 27 IDTECA PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 15 RMA Request Form e RMA REQUEST FORM ORIGINAL IDTECK Co Ltd yes ID CASH POINT 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea TEL 82 2 2659 0055 FAX 82 2 2659 0086 www idteck com RMA REQUEST FORM Send to RMA No amp Date RMA Customer Service Original Invoice No amp Date 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Requested from Sales Person In Charge Akr Vessel __ Departure Date NO f Model SerialNumber Serial Number Error Check Box by shipper O O OS 232 Com o Power o Card Reading o Engineer i Input Output o Keypad o RS 422 Com o Comment Others 0 RS 232 Com o Power o Card Reading o Engine
21. he system Besides the above configurable I O interfaced behaviors many of the IPASS IP 100R internal behaviors are programmable as well The internal operating parameters include the number of incorrect access attempts before alarm condition is triggered tampering protection from mounting removal and timers Furthermore every event or transaction can be captured and time stamped by the iPASS IP 100R application software via the provided RS 232 wires IDTECK 3 APASS P 100R 3 Feastures PIN amp Proximity PINPAD Single Door Access Controller Single Door Access Controller with PIN amp Proximity PINPAD Basic Time amp Attendance Function 512 Card Holders Built in 4 10cm ASK EM Format RF Reader Operation Mode selectable RF Only PIN 4 6 digits Only RF and P W 4 digits RF or PIN 4 6 digits External Reader Port for Exit 26Bit Wiegand Format Standalone or Communication via RS232 Independent 5 Inputs and 4 Outputs including 2 ouput relays All I O and operating times programmable using keypad Try out error alarm Optional 4ch Voice Auto dialer 3 LEDs for system operation status Back Lighting on Keypad Toggle Mode for Door Opening Closing Function for Lock Control by Door Contact Switch Setting for Safe Secure Mode Duress Alarm Function Chime Bell Available Dual Tamper Switches 4 Specification CPU Memory PIN Number Read Range Reading Time Reading Forma
22. n of each card 4 The first card read becomes the Configuration Card and the following RF Cards are registered as User Access Cards Once all User Access Cards have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in a secure location for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10 2 Registration of RF Cards with PINs for RF CARD PIN MODE 1 Apply 12VDC to the unit All 3 LEDs will be flashing along with a powered up melody do mi sol me do do mi sol do 2 Press o 2 ent from the keypad RF CARD PIN MODE 3 Present RF Cards as follow to register Configuration Card and User Access Cards 4 6 digit Personal Identification Number PIN for each User Access Card 2 Configuration Card User Access Cards PINs Configuration Card again to end task 4 The first card read becomes the Configuration Card and the following RF Cards PINs are registered as User Access Cards with assigned PINs Once all User Access Cards and PINs IDTECX 11 o PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller have been registered present the Configuration Card again to complete the registration Please keep the Configuration Card in a secure location for future changes 5 Now the Main Unit is entered into the normal operation mode with factory defaulted settings 10
23. o PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller USER S MANUAL APASS P 100R PIN amp Proximity PINPAD Single Door Access Controller Rev 5 1 0 Rev 2 1 0 IDTECK PIN amp Proximity PINPAD IPASS P 100R Single Door Access Controller Table of Contents l Important Safety Instructions Laan 3 2 BENG ANAN AA AGA 3 3 Feas tiros wit 4 A SPCCINCAUON drsni net 4 Bs FROME Pall DGS CED UO 0 coin cvsunesansiunexagsinavsevaunvasisusvndtiovusinancauabausnaueareavesseunbuiavainerin 5 IGENUEVING SUP DUCE Pal eS saa AA ANAN 5 Fe NANDO ANAN AA NAA AA 6 8 Color Coded and Wiring Table sssssssssscssscssssscssesessesevsesevsssecaesecessecevsesevassenanas 7 9 System Wiring for Typical Application aaa 8 10 INVALID sini 11 Lk ODETA DO Naa AA AA AA 13 EZ SEUNG CNANOES AA AA AA AA 15 EAE AUG A maa ANAN AA AA 26 14 FCC Registration Information aaa 27 15 RMA Reg uest Fori tireancinariccianerinniannsiniinniiseeneneiieitiD 28 16 Warranty aNd S CIVIC GAAN AA AA 30 LIP Ale NAAN A A AA 31 IDTECA pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 1 Important Safety Instructions When using your iPASS IP 100R basic safety precautions should always be followed to reduce the risk of fire electrical shock and injury to persons In addition the following should also be followed Read and understand all instructions 2 Follow all warnings and instructions marked on the pr
24. oduct 3 Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning If necessary use mild soap 4 Do not use this product near water such as bath tub wash bowl kitchen sink laundry tub in a wet basement or swimming pool maa 5 This product should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your installation site consult your dealer or local power company 6 Never push objects of any kind into this product or through the cabinet slots as they may touch voltage points or short out parts that could result in fire or electric shock Never spill liquid of any kind on the product 7 To reduce the risk of electric shock do not disassemble this product by yourself but take it to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is damaged or frayed b If liquid has been spilled on the product c Ifthe product does not operate normally after following the operating instructions in this manual Adjust only those controls that are covered by the operating instructions in this manual Improp
25. on The key can be used to activate an external Chime Bell for 5 seconds the defaulted value BELL 14 IDTECA pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 12 Setting Changes Configuration Card PIN is required to change existing or defaulted setting values or to manage user s access First present the Configuration Card or enter the Configuration PIN and enter the 2 digit command code RF Only Mode or RF PIN Mode PIN Only Mode or Configuration Card Command Code Configuration PIN Command Code Summary Table of Commands Command Action Change setting values 11 Add User Access Cards RF CARD ONLY MODE 12 Add User Access Cards and PIN RF CARD PIN MODE 13 Add User Access PIN numbers PIN ONLY MODE 14 Delete User Access Cards or PIN 21 Change Door open time when User Access Card or PIN is granted 22 Change Alarm time when User Access Card or PIN is denied 23 Change Alarm time when Try Out error detected 24 Change Alarm time when Door Contact error detected 20 Change Alarm time when Aux Input 1 detected 26 Change Alarm time when Aux Input 2 detected 21 Change Alarm time when Aux Input 3 detected 28 Change Alarm time when magnet detected 29 Register 2 digits Duress Alarm password 30 Change Alarm time when Duress Alarm detected 31 Test Door open time set by command 21 32 Test Alarm time set by command 22 33 Test Alarm time set by command 23 34 Test Alarm
26. s the factory defaulted setting values below to execute the normal operation mode You may want to change these factory setting values or modify your User Access list refer to section 12 for instructions on how to customize the operation of your unit 12 IDTECA PIN amp Proximity PINPAD o PASS P 100R Single Door Access Controller 1 When User Access Card or PIN is granted GEILO3 S Door RELAY activates for 3sec Green LED lights on for 3sec 2 When User Access Card or PIN is not recognized Alarm RELAY activates for 2sec Red LED lights on for 2sec gt B 02 S 3 Duress Password 00 Duress Alarm to TTL output port for 03 sec 4 QUICK ACCESS MODE Disable 5 Chime Bell output Enable Chime Bell activation time 05 sec 6 Melody sound Enable 7 Keypad lock out time when Try Out error detected 01 min 0 1 8 Detect all inputs from H to L 9 Activate TTL output to L 10 Delay time to activate SECURE MODE 00 min 11 Door Open time out for Door Contact sensor 00 sec 12 Number of times of Try out 05 times 13 Input keypress time out time 20 sec 14 Tamper Alarm Disable Tamper Alarm output port 02 Alarm Relay 15 Toggle Mode Disable 16 Unlock followed by Door Contact Disable 11 Operation 11 1 Normal operation Mode Safe Mode When the Main Unit operates in normal mode the yellow LE
27. t Card Holders Input Ports Output Ports External Reader Port Communication Keypads Self Diagnostic LED Indicators Power Operation Environment Reset Color Weight IDTECA IPK50 IPC170 IPC80 Relay Output TTL Output Chime Bell Output Dual 8Bit Microprocessors Program Memory 20KByte ROM Data Memory 2KByte EEPROM 512 PIN Numbers 2 inch 5cm 4 inch 10cm 4 inch 10cm 30ms ASK EM Format 512 Card Holders bea 2ea COM NO NG lea lea 1 ea 26 Bit Wiegand Format RS232 Baud Rate 9600bps 12Key Numerric Keypad with Back Lighting Yes 3 LEDs Red Green Yellow DC12V Max 200mA 35 C 65 C 31 F 149 F 10 90 RH Non Condensing Watch Dog Timer amp Power on Reset Dark Pearl Gray 210g 0 464 Ibs o PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 5 Front Panel Description STAR 100R PIN120 Main Unit LED Display Keypad 6 Identifying Supplied Parts Please unpack and check the contents of the box o O Q O MainUnit Wall Mount O Ring Manual lea lea 5ea lea IDTECA PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 7 Installation 7 1 Tear off page 27 and use the provided template to drill two 6 32 holes and one 1 2 hole on the proper location of the wall to mount the Wall Mount bracket as shown below If the gang box is already installed on the wall then skip this step 6 32 hole
28. vate TTL Output to L TTL output changes the state from logic 1 to logic 0 when it activates Defaulted setting Configuration Card Configuration PIN 12 77 Enable Chime Bell Output Configuration Card Configuration PIN Defaulted setting E nable 12 78 Disable Chime Bell Output Configuration Card Configuration PIN IDTECA 23 pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 12 80 Set Delay Time to Activate SECURE MODE mm 00 99 min Defaulted Delay time 00 min sien mien Configuration Card Command Delay time Configuration PIN 12 81 Set Door Open Time out for Door Contact Sensor tt 00 99 sec Defaulted value 00 sec means no detect Door Contact Sensor refer to 12 24 for Alarm time settings N3 Gua Configuration Card Command Door Open time out Configuration PIN 12 82 Set Number of Times of Try Out NN 00 99 times Defaulted Try out numbers 05 times ooz x Olen Configuration Card Command Try out numbers Configuration PIN 12 83 Set Input Keypress Time out Time tt 10 99 sec Defaulted Keypress time out 20 sec Minimum tt 10 sec Configuration Card Command Keypress time out time Configuration PIN 12 84 Set Tamper Alarm Output Port Refer to Table 1 for OM Defaulted Output port 02 Alarm Relay 8 4 Enr o ma fent Configuration Card Command Alarm Output Port Configuration PIN 12 88 Enable Tamper Alarm To compl
29. y with UL 294 the Standard for Access Control System Units the Tamper Alarm must be enabled IDTECA 24 pa PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller Configuration Card Configuration PIN 12 89 Disable Tamper Alarm Configuration Card Configuration PIN 8 9 Je Defaulted setting 12 99 Re Initialize and Erase All Setup Data Please use this command when you really want to erase all data and start the unit from the beginning Configuration Card Configuration PIN oon p Additional Function 12 73 Enable Keypad Input To Enter ID Number Keypad input is enabled to enter the ID numbers through keypads Configuration Card Configuration PIN 12 74 Disable Keypad Input To Enter ID Number Keypad input is disabled to enter the ID numbers through keypads Configuration Card Configuration PIN AWE Defaulted setting 25 IDTECA o PIN amp Proximity PINPAD PASS P 100R Single Door Access Controller 13 Initialization When you lost the Configuration Card or forgot the Master PIN number you may need to re initialize the unit for new setup There is a hard wired Initialize function on the unit X WARNING You may lose all setup data after execute Initialize 13 1 Hardware Initialization When the master card or ID is lost 1 Open the top case taking out four bolts on the back 2 As the left picture make two jumpers short in state of being on power 3 3 color LE