Home
Operating Instructions - Lock fitting ARV-SG63.1 for
Contents
1. e Documentation this operating instructions manual 3 2 Principle of operation The lock fitting ARV SG63 1 is a threaded fitting and can be used together with a level sensor in tube version VEGA SWING 63 Depending on the version the tube extension of the sensor must have a diameter of 21 3 mm 0 84 in ARV SG63 1 cannot be used in coated tubes The wetted parts of the ARV SG63 1 are made of steel 316L The ARV SG63 1 must only be used in unpressurized vessels With the lock fittings sensors with tube extension can be fixed infinitely The terminal screws protect the tube against sliding through The following versions are available e 221 3 mm G1A or 1 NPT SW 41 e 221 3 mm G1 A or 1 NPT SW 60 3 3 Storage and transport Your instrument was protected by packaging during transport lts capacity to handle normal loads during transport is assured by a test acc to DIN EN 24180 The packaging of standard instruments consists of environ ment friendly recyclable cardboard For special versions PE foam or PE foil is also used Dispose of the packaging material via specialised recycling companies e Storage and transport temperature see Supplement Technical data Ambient conditions e Relative humidity 20 85 Lock fitting ARV SG63 1 unpressurised operation 5 Mounting VEBA 4 Mounting 4 1 Mounting procedure The numbers in brackets refer to the illustration
2. Operating Instructions Lock fitting ARV SG63 1 for VEGASWING 63 unpressurised operation Contents VEBA Contents 1 About this document Jad PONCHO sert aaa iraani oe ee ee de ae 4 1 2 Target groUP zuxwa boca Se cedue decd bada 4 1 3 Symbolism used 4 2 For your safety 2 1 Authorised personnel 5 2 2 Appropriate use 5 2 3 Warning about misuse 5 2 4 General safety instructions 5 2 5 Environmental instructions 5 3 Product description 3 1 Configuration n a aaa aaa aeaa 6 3 2 Principle of operation 6 3 3 Storage and transport 6 4 Mounting 4 1 Mounting procedure 7 5 Maintenance and fault rectification 5 1 Maintenance 000 eee ee 8 5 2 Instrument repair 0 000 ee 8 6 Dismounting 6 1 Dismounting procedure 9 62 Disposal mah KALI KGAD ecu deds 9 7 Supplement 7A Technical data 4 10 7 2 DIMENSIONS mawa DG BAG Oeakeea MD NAG KAG 11 Lock fitting ARV SG63 1 unpressurised operation vO80S0 N3 0S26e 29750 EN 050804 V O br Vv About this document 1 About this document 1 1 Function This operating instructions manual has all the information you need for quick setup and safe operation of AR
3. V SG63 1 Please read this manual before you start setup 1 2 Target group This operating instructions manual is directed to trained personnel The contents of this manual should be made available to these personnel and put into practice by them 1 3 Symbolism used Information tip note This symbol indicates helpful additional information Caution warning danger This symbol informs you of a dangerous situation that could occur Ignoring this cautionary note can impair the person and or the instrument Ex applications This symbol indicates special instructions for Ex applications List The dot set in front indicates a list with no implied sequence Action This arrow indicates a single action Sequence Numbers set in front indicate successive steps in a procedure Lock fitting ARV SG63 1 unpressurised operation 3 For your safety VEBA 2 For your safety 2 1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialised personnel authorised by the operator For safety and warranty reasons any internal work on the instruments must be carried out only by personnel authorised by the manufacturer 2 2 Appropriate use ARV SG63 1 is used for for infinite locking with tube extension Detailed information on the application range of ARV SG63 1 is available in chapter Product description 2 3 Warning about misu
4. ismounting procedure Note chapter Mounting and carry out the described steps in reverse order If you proceed as follows it is not necessary to readjust the switching point and the lock fittings must not be dismounted completely 1 Switch off power supply of the sensor 2 Remove all connection cables 3 Loosen lock fitting with a screwdriver 4 Remove the sensor together with the lock fitting 6 2 Disposal The ARV SG63 1 consists of materials which can be recycled by special recycling companies Mark the instrument as scrap and dispose it according to the legal regulations Materials see Technical data If you cannot dispose of the instrument properly please contact us about disposal methods or return Lock fitting ARV SG63 1 unpressurised operation vO80S0 N3 0S26e 29750 EN 050804 VEBA 7 Supplement 7 1 Technical data General data Supplement Material 316L corresponds to 1 4404 or 1 4435 Process fitting G1Aor1 NPT G1 A or 1 NPT Tube diameter of the sensor Materials Lock fitting Process seal Terminal screws Torque Terminal screws M5 Process conditions Operating pressure Product temperature Approvals The lock fittings have no own approvals 21 3 mm 0 84 in 316L Klingersil C 4400 Pin with hexagon DIN 913 M5 x 8 4 1 Nm 3 0 7 Ibf ft unpressurized 50 250 C 58 482 F D not with thread NPT Lock f
5. itting ARV SG63 1 unpressurised operation 9 VEBA 7 2 Dimensions Lock fitting ARV SG63 1 for VEGASWING 63 20mm 25 32 Fig 2 Lock fitting ARV SG63 1 unpressurized for VEGASWING 63 10 Lock fitting ARV SG63 1 unpressurised operation 708090 NA 05Z6c 29750 EN 050804 VEBA Lock fitting ARV SG63 1 unpressurised operation 11 VEBA VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone 49 7836 50 0 Fax 49 7836 50 201 E mail info de vega com www vega com O CE amp All statements concerning scope of delivery application practical use and operating conditions of the sensors and processing systems correspond to the information avail able at the time of printing Technical data subject to alterations 29750 EN 050804
6. s on the following pages Fig 1 Lock fitting ARV SG63 1 unpressurised 1 2 Lock fitting Terminal screws 3 pcs Screw the lock fitting 1 with a resistant seal ring into the thread of your vessel and tighten the lock fitting 1 on the hexagon Clean the connection tube of the sensor and the lock fitting carefully and remove grease oil and dirt Insert the sensor into the lock fitting Slide the tube into the requested position and hold it Make sure that the sensor is in the correct position height The height adjustment of the sensor determines also the switching point Tighten the terminal screws 2 with a torque of 4 1 Nm 3 0 7 Ibf ft The terminal screws 2 press lightly into the tube and fix the tube of the sensor in this position Lock fitting ARV SG63 1 unpressurised operation vO80S0 N3 0S26e 29750 EN 050804 A l oe W 5 N Maintenance and fault rectification 5 Maintenance and fault rectification 5 1 Maintenance When used as directed in normal operation lock fitting ARV SG63 1 is completely maintenance free 5 2 Instrument repair If a repair of ARV SG63 1 should be necessary please send the instrument to the following address VEGA Grieshaber KG Abteilung Reparatur Am Hohenstein 113 77761 Schiltach Germany Lock fitting ARV SG63 1 unpressurised operation 7 Dismounting VEBA 6 Dismounting 6 1 D
7. se Inappropriate or incorrect use of the instrument can give rise to application specific hazards e g vessel overfill or damage to system components through incorrect mounting or adjustment 2 4 General safety instructions ARV SG63 1 is a high tech instrument requiring the strict observance of standard regulations and guidelines The user must take note of the safety instructions in this operating instructions manual the country specific installation standards e g the VDE regulations in Germany as well as all prevailing safety regulations and accident prevention rules 2 5 Environmental instructions Protection of the environment is one of our most important duties That is why we have introduced an environment management system with the goal of continuously improving company environmental protection The environment man agement system is certified acc to DIN EN ISO 14001 Please help us fulfil this obligation by observing the environ mental instructions in this manual e Chapter Storage and transport e Chapter Disposal Lock fitting ARV SG63 1 unpressurised operation vO80S0 N3 0S26e 29750 EN 050804 VEBA Scope of delivery Area of application Physical principle Packaging Storage and transport tem perature Product description 3 Product description 3 1 Configuration The scope of delivery encompasses e Lock fitting ARV SG63 1 for VEGASWING 63 vibrating level switch
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi www.juwel-aquarium.com 701992 Xviewer ユーザーズマニュアル - Catalogue.bosal.com Philips HTB3280G Scarica l`allegato Copyright © All rights reserved.
Failed to retrieve file