und Montageanleitung Installation and Operating

image

Contents

1. Zum START des Ger tes muss die Klemme S33 mit S34 ber einen Schlie Berkontakt berbr ckt werden Danach sind die Kontakte 13 14 23 24 33 34 geschlossen der Kontakt 41 42 ge ffnet Die LED s Channel 1 und Channel 2 leuchten In Reihe zu dem START Taster kann die Schaltung eines externen Sch tzes berwacht werden siehe Anwendungsbeispiel 3 BERNSTEIN safe solutions Assembly and function function circuit diagram 1a 24 34 42 Output contacts safety circuits normally open auxiliary circuits normally close START button EMERGENCY STOP channel 1 and 2 The supply voltage must be applied at terminals A1 and A2 The Power LED illuminates Terminals S11 S12 S21 and S22 have to be wired up as shown in the corre sponding application examples To START the device terminals S33 and S34 must be bridged with a normally open contact The device operates when you close this contact After that the contacts 13 14 23 24 and 33 34 are closed contact 41 42 is opened The LED s Channel 1 and Channel 2 illuminate Connected in series to the START button the circuit of an external contactor can be monitored see application example 3 Ausgabedatum Date of issue 21 06 2005 Seite Page 3 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein ag de Vorlag
2. Carry out the wiring according to the intended the use Follow the application examples In general the safety relay has to be wired acc to the following instructions 1 Close the feedback control loop and the activation circuit Automatic activation Bridge terminals S33 834 Conditional activation amp Connect START button to S33 S34 no bridge on 833 834 N C contacts of external contac tors are wired in series with the START button at the terminals 833 834 automatischer Start without start control Start ber Start T ste und Anschlu Maschinenfreigabekreise Sch tzkontrolle Start with start bottom and detection of external Ausgabedatum Date of issue 21 06 2005 Seite Page 4 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein ag de Vorlage Template 0850174292 Orig 2 Bedienungs und Montageanleitung Installation and Operating Instructions 2 Eingangskreis schlie en amp Einkanalig Schlie en Sie den Kontakt des Ausl se elementes an die positive Versorgungsspannung und die Anschlussklemme A1 an amp Zweikanalig Schlie en Sie die Kontakte des Sicher heitsschaltger tes an S11 S12 und S21 S22 an Ausl se element trigger element A1 A2 einkanalig single channel Die Verdrahtung der Versor gungsspannung ist abh ngig vom Ger tetyp
3. 50 C 32 122 F 25 55 C 13 F 131 F IP 20 DIN VDE 0470 Teil 1 part 1 IP 40 DIN VDE 0470 Teil 1 part 1 Sto festigkeit Schlie er ffner shock resistance 8g 2g N O N C contacts CE Konformit t Conformity ja yes Zulassungen Approvals TUV UL C UL Subject to technical modifications all information are supplied without liability Ausgabedatum Date of issue 21 06 2005 Seite Page 7 von of 9 Technische nderungen vorbehalten alle Angaben ohne Gew hr Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein ag de Vorlage Template 0850174292 Orig 2 Bedienungs und Montageanleitung Installation and Operating Instructions START NOT AUS EQ STOP n amp 2 2 2 0 0 0 0 0 0 0 8 AM AA S21 S22 Sit S12 1323334 Me ee ee Bis Steuerungskategorie 2 Up to control category 2 Siehe Hinweis auf Seite 9 See note on page 9 24V ACDC Bis Steuerungskategorie 4 Up to control category 4 Bis Steuerungskategorie 4 Up to control category 4 24V ACDC START OPETE ETE E S33 S4 At Aal S S2 S S2 1 E m Bis Steuerungskategorie 2 Up to control category 2 Siehe Hinweis auf Seite 9 See note on page 9 Subject to technical modifications all information are supplied without liability Technische Anderungen vorbehalten all
4. ag de Vorlage Template 0850174292 Orig 2
5. f r NOT AUS und Schutzt ranwendungen Installation and Operating instruction Safety controller for E STOP and safety guard monitoring applications Introduction This installation and operating instruction shall make you familiar with tne emer gency stop and safety guard monitoring relay SCR 4 W22 3 5 D The operating instruction is addressed to the following persons Qualified professionals who plan and develop safety equipment for ma chines and plants and who are famil iar with the regulations for occupa tional safety and accident prevention Qualified professionals who install safety equipment into machines and plants and put them into operation This operating instruction contains sev eral symbols which are used to highlight important information This symbol is placed in front of text which has to be strictly noticed Nonobservance leads to serious injuries or damage to property This symbol is placed in front of text which contains important information This sign marks operations to be exe cuted After this sign follows a description on how the status has changed after execu tion of the operation Ausgabedatum Date of issue 21 06 2005 Seite Page 1 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein ag de Vorlage Template 0850174292 Orig 2 Bedienungs und Montageanleitung
6. the safety guard switches are closed the output contacts remain unchanged After the release of the device the con tacts 13 14 and 23 24 close After open ing the safety guard switches the con tacts return to their normal position with out delay Example 6 Dual channel safety guard monitoring with automatic activation and with opposite polarity between channels The activation works automatically since the terminals S33 S34 are bridged When the safety switches at the safety guard are closed the contacts 13 14 23 24 and 33 34 will close When the safety switches at the safety guard are opened the contacts return to their normal posi tion without delay The automatic START already takes place when the device is connected to the supply voltage Wiring notes for the output terminals 13 14 23 24 33 34 and 41 42 The voltage L respective 24 V DC and not GND should be routed via the outputs in order to recognize shorts to GND or earth To reduce the wear of the contacts we recommend the use of an R C combina tion connected in parallel to the load Additional note With a wiring according to application example 1 and 4 the user must provide a connection to the machine control for cyclic testing Ausgabedatum Date of issue 21 06 2005 Seite Page 9 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein
7. Bedienungs und Montageanleitung Installation and Operating Instructions Zielgruppe Target group Zeichenerkl rung Signs and symbols Subject to technical modifications all information are supplied without liability Technische nderungen vorbehalten alle Angaben ohne Gew hr Einleitung Diese Bedienungs und Montageanlei tung soll Sie mit dem NOT AUS Sicher heitsrelais und Schutzt rw chter SCR 4 W22 3 5 D vertraut machen Die Bedienungsanleitung richtet sich an folgende Personen Qualifizierte Fachkr fte die Sicher heitseinrichtungen f r Maschinen und Anlagen planen und entwickeln und mit den Vorschriften ber Arbeitssi cherheit und Unfallverh tung vertraut sind Qualifizierte Fachkr fte die Sicher heitseinrichtungen in Maschinen und Anlagen einbauen und in Betrieb nehmen In dieser Bedienungsanleitung werden einige Symbole verwendet um wichtige Informationen hervorzuheben Dieses Symbol steht vor Textstellen die unbedingt zu beachten sind Nicht Be achtung f hrt zur Verletzung von Perso nen oder zu Sachsch den Dieses Symbol kennzeichnet Textstellen die wichtige Informationen enthalten Dieses Zeichen kennzeichnet auszuf h rende T tigkeiten Nach diesem Zeichen wird beschrieben wie sich der Zustand nach einer ausge f hrten T tigkeit ndert BERNSTEIN safe solutions SCR 4 W22 3 5 D 607 5111 009 Bedienungs und Montageanleitung Sicherheitsschaltger t
8. Installation and Operating Instructions Bestimmungsgem e Verwendung Intended Use Q Zu Ihrer Sicherheit For your safety Subject to technical modifications all information are supplied without liability Technische nderungen vorbehalten alle Angaben ohne Gew hr Sicherheitshinweise Das Sicherheitsrelais SCR 4 ist be stimmt f r den Einsatz in Einkanalige und zweikanalige Schal tungstechnik f r NOT AUS oder Schutzt r berwachungen ohne berwachung des Start Tasters Personen und Sachschutz sind nicht mehr gew hrleistet wenn das Sicher heitsrelais nicht entsprechend seiner bestimmungsgem en Verwendung eingesetzt wird Beachten Sie unbedingt die folgenden Punkte Das Ger t darf nur unter Beachtung dieser Betriebsanleitung von Fach personal installiert und in Betrieb ge nommen werden das mit den gel tenden Vorschriften ber Arbeitssi cherheit und Unfallverh tung vertraut ist Elektrische Arbeiten d rfen nur von Elektrofachkr ften durchgef hrt werden Beachten Sie die jeweils g ltigen Vorschriften insbesondere hinsicht lich der Schutzma nahmen 5 Reparaturen insbesondere das Off nen des Geh uses d rfen nur vom Hersteller oder einer von ihm beauf tragten Person vorgenommen wer den Ansonsten erlischt jegliche Ge w hrleistung Vermeiden Sie mechanische Er sch tterungen beim Transport oder im Betrieb St e gr er 5g 33Hz k nnen zur Besch dig
9. e Angaben ohne Gew hr Anwendungsbeispiele 1 6 ohne Uberwachung des START Tasters Beispiel 1 Einkanalige NOT AUS Schaltung ohne Quer schlusssicherheit Mit dem Starttaster wird das Ger t akti viert Die Kontakte 13 14 23 24 und 33 34 schlie en ber den NOT AUS Tas ter fallen die Kontakte in ihre Grundstel lung zur ck Beispiel 2 Zweikanalige NOT AUS Schaltung mit Querschlusssicherheit Bei der zweikanaligen NOT AUS Schal tung mit Querschlusssicherheit wird der Klemmenanschluss S11 S12 S21 und S22 verwendet Mit dem START Taster wird das Ger t aktiviert Die Kontakte 13 14 23 24 und 33 34 schlie en Uber den NOT AUS Taster fallen die Kontakte in ihre Grundstellung zur ck Beispiel 3 Zweikanalige NOT AUS Schaltung mit externer Kontakterwei terung 2 Sch tze Kontakt berwa chung und Querschlusssicherheit In diesem Beispiel werden zwei externe Sch tze mit Kontaktzwangsf hrung ver wendet Je ein Offnerkontakt dieser bei den Sch tze muss in Reihe zum START Taster an die Klemmen S33 und S34 angeschlossen werden Uber einen Schalter S ext k nnen die externen Sch tze zu einem beliebigen Zeitpunkt dazugeschalten bzw abgeschalten wer den wenn das SCR 4 aktiviert ist Die Anschlussleitungen f r die Sch tze soll ten zur Vermeidung von Querschl ssen getrennt verdrahtet werden Beispiel 4 Einkanalige Schutzt r berwachung ohne Querschlusssi cherheit Wird d
10. e Template 0850174292 Orig 2 Bedienungs und Montageanleitung Installation and Operating Instructions Mechanische Montage Mechanical installation Ag Elektrischer Anschluss Electrical connection f Subject to technical modifications all information are supplied without liability Technische Anderungen vorbehalten alle Angaben ohne Gew hr Montage und Inbetriebnahme F r eine sichere Funktion muss das Si cherheitsrelais in ein staub und feuchtig keitsgesch tztes Geh use eingebaut werden IP54 Montieren Sie das Sicherheitsre lais auf eine Normschiene F hren Sie die Verdrahtung entspre chend des Verwendungszweckes durch Orientieren Sie sich dabei an den An wendungsbeispielen Generell ist das Sicherheitsrelais nach folgenden Anga ben zu verdrahten 1 Aktivierungs und R ckf hrungskreis schlie en Automatische Aktivierung Br cken Sie die An schlussklemmen S33 S34 Bedingte Aktivierung amp START Taster an S33 S34 anschlie en keine Br cke an S33 S34 Ex terne Sch tze werden in Reihe zum START Taster an die Klemmen S33 S34 angeschlossen A a COREE NAAN S33 534 Start ber Start Taste with start control BERNSTEIN safe solutions Installation and initial operation The device should be panel mounted in an enclosure rated at IP 54 or better otherwise moisture or dust can lead to malfunction e7 Attach the safety relay to a DIN Rail
11. er Schutzt rschalter S1 geschlos sen bleiben die Ausgangskontakte un ver ndert Erst mit Freigabe wird das Ger t aktiviert Die Kontakte13 14 23 24 und 33 34 schlie en Beim ffnen des Schutzt rschalters S1 die Kontakte in ihre Grundstellung zur ck Achtung Die Abfallverz gerung kann sich bei 230V AC Ger ten bis zu 100 ms vergr ern BERNSTEIN safe solutions Application examples 1 6 without monitoring the START button Example 1 EMERGENCY STOP circuit without opposite polarity between channels Pressing the START button the device will be activated The contacts 13 14 23 24 and 33 34 close Pressing the EMERGENCY Stop button initiates a stop and the output contacts open Example 2 Dual channel EMERGENCY STOP circuit with op posite polarity between channels For this application the terminal wiring S11 S12 S21 and S22 must be used With the START button the device will be activated The contacts 13 14 23 24 and 33 34 are closed Pressing the EMER GENCY Stop button initiates a stop and the output contacts open Example 3 Dual channel EMER GENCY STOP with external contact extension 2 contactors contact monitoring and opposite polarity be tween channels This application uses two external con tactors with forcibly guided contacts One normally closed contact of each external contactor must be connected in series with the START button to the terminals S33 and S34 Through the swi
12. ernstein ag de Vorlage Template 0850174292 Orig 2 Bedienungs und Montageanleitung BERNSTEIN Installation and Operating Instructions safe solutions Technische Daten Technical Data Elektrische Daten Electrical data Versorgungsspannung Uv supply voltage Spannungsbereich voltage range Frequenz AC Variante frequency AC type Leistungsaufnahme ca power consumption appr Leitungsdaten Conductor data Leiteranschlu conductor connection Max Leitungsl ngen Eingangskreis max conductor length input circuit Leiterquerschnitt conductor cross section Kapazit t capacity Temperatur temperature Kontaktdaten Contact data Kontaktbest ckung contact configuration Kontaktart contact type Kontaktmaterial contact material Schaltspannung switching voltage Schaltstrom switching current Max Schaltverm gen max switching capability DIN EN 60947 5 1 Schaltleistung max max switching capacity Mechanische Lebensdauer mechanical life Elektrische Lebensdauer electrical life Kriech und Luftstrecken creapage and clearance distances Kontaktabsicherung contact protection Wiederbereitschaftszeit ready after time delay R ckfallverz gerung K1 delay on deenergisation K1 Mechanische Daten Mechanical data Geh usematerial enclosure material Abmessungen BxHxT in mm dimensions WxHxD Befestigung mounting Luftfeuchtigkeit air humidity Umgebungsdaten Env
13. f the device we advise to unscrew the cables 1 to 1 from the de fective device and to screw them in place again on the exchange device 1 You must screw of the cable and screw on the exchange device 2 Take away the defective device from the DIN Rail 3 Mount the exchange device on the DIN Rail Fehler St rungen Auswirkung und Ma nahmen Die Sicherung l st aus Die Ausgangs kontakte ffnen Nach Wegfall der St r ursache und Einhalten der Betriebsspan nung ist das Ger t wieder betriebsbereit Bei verschwei ten Kontakten ist nach Offnen des Ausgangskreises keine neue Aktivierung m glich Externer Beschaltungsfehler oder inter ner Fehler Externe Beschaltung pr fen Wenn Fehler immer noch vorhanden Ger t an BERNSTEIN AG einschicken Faults effects and measures The electronic fuse releases The output contacts open Once the cause of the failure is removed and the supply voltage is observed the device is ready for op eration In case of welded contacts and next to opening of the input circuit a further acti vation is not possible An external wiring fault or an internal fault is present Verify the external wiring When the fault is still present send the device to BERNSTEIN AG Ausgabedatum Date of issue 21 06 2005 Seite Page 6 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www b
14. ironmental data Umgebungstemperatur operating temperature range Schutzart Klemmen degree of protection terminals Schutzart Geh use degree of protection enclosure Version 24V AC DC or Version 230V AC or Version 110V AC 0 90 1 1 Uv 50 60 Hz 110 230V ca 3 7 VA 24V DC 3 W 24V AC 5 VA 2x 1 5 mm Massivdraht solid wire 2x1 5 mm Litze mit H lse strand with wire end ferrule DIN VDE 46228 2 x 100m einkanalig single channel 4 x 100m zweikanalig dual channel 2x 1 5 mm 4 x 1 5mm 150 nF km 25 C 77F 3 Schlie er 1 ffner 3 N O contacts 1 N C contact Relais zwangsgef hrt relay forcibly guided contacts AgSnO oder vergleichbares Material AgSnO or comparable material 230V AC 24V DC 5A AC 15 230 V 5A DC 13 24V 5A 1250 VA ohmsche Last 1250 VA ohms load 107 Schaltspiele operations 10 Schaltspiele operations DC 24V 2A DIN VDE 0160 f r Verschmutzungsgrad 2 berspannungskategorie 3 250 V DIN VDE 0160 at pollution grade 2 over voltage category 3 250 V Basisisolierung berspannungskategorie 3 250 V basis isolation over voltage category 3 250 V Schlie er 6 3A flink NO contact 6 3A brisk ffner 4A Neozed gL gG NC contact 4A Neozed gL gG lt 1s lt 30 ms 24V AC lt 50ms Polyamid polyamide PA 6 6 22 5 x 114 5 x 99 Schnappbefestigung f r Normhutschiene click fastening for DIN Rail Wechselklima swap climate 95 0
15. peration Shocks greater than 5 g 33 Hz may lead to damage of the device The device shall be panel mounted in an enclosure rated at IP 54 or better otherwise moisture or dust can lead to malfunctions Adequate fuse protection must be provided on all output contacts with capacitive and inductive loads The emergency stop relay shall be test in regular time intervals at least every six month or along with the maintenance cycle of the installa tion Ausgabedatum Date of issue 21 06 2005 Seite Page 2 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein ag de Vorlage Template 0850174292 Orig 2 Bedienungs und Montageanleitung Installation and Operating Instructions 13 14 23 24 33 34 41 42 S33 534 S11 S12 S21 522 Subject to technical modifications all information are supplied without liability Technische nderungen vorbehalten alle Angaben ohne Gew hr Aufbau und Funktionsweise U berwachunggslogik monitoring logic Ausgangskontakte Sicherheitsstrompfade Schlie er Signalisierungsstrompfad ffner Start Taster NOT AUS Kanal 1 und 2 F r das Betreiben des Ger tes muss eine Hilfsspannung an die Klemmen A1 und A2 angelegt werden Die LED Po wer leuchtet Die Anschlussklemmen S11 S12 S21 und S22 werden nach den entsprechen den Anwendungsbeispielen beschaltet
16. siehe Typen schild am Ger t 3 Versorgungsspannung Uv 24V AC DC oder 115V AC 230V AC amp Einkanalig Schlie en Sie die Versorgungsspannung Uv L Phase ber den Sicherheitskontakt des NOT AUS bzw Schutzt rschalters an die Klemme A1 an Schlie en Sie den Uv Uvn Nullleiter direkt an die Klemme A2 an Bei 115V und 230V Ger ten muss der Erdanschluss an S21 angeschlossen werden Zweikanalig Schlie en Sie die Versorgungsspannung an die Klemmen A1 und A2 an Beachten Sie unbedingt die maximalen Leitungsl ngen Subject to technical modifications all information are supplied without liability Technische nderungen vorbehalten alle Angaben ohne Gew hr BERNSTEIN safe solutions 2 Close input circuit amp Single channel Connect contacts from trigger element to positive supply voltage and Al amp Dual channel connect the contacts from the safety switching device safety switching device to S11 S12 andS21 S22 Ausl se element trigger element De W no dependent on the device version see type plate on the device Supply voltage Uv 24V AC DC or 115V AC 230V AC S Single channel The supply voltage Uv L has to be routed over the safety con tact from the E STOP safety guard switch to terminal A1 Connect Uv Uvn neutral wire directly to ter minal A2 amp With 115V and 230V devices the gro
17. tch S ext the external contactors can be operated or turned off at any time if the SCR 4 is activated To avoid short circuits across the connecting lines of the contactors a separated wiring shall be used Example 4 Single channel safety guard monitoring without opposite polarity between channels If the safety switch S1 at the safety guard is closed the output contacts do not change Pressing the START button activates the SCR 4 The contacts 13 14 23 24 and 33 34 close When opening the safety switch at the safety guard the contacts return to their normal position without delay Attention The fall back time can in crease up to 100 ms with 230V AC ver sions Ausgabedatum Date of issue 21 06 2005 Seite Page 8 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein ag de Vorlage Template 0850174292 Orig 2 t l L Bedienungs und Montageanleitung Installation and Operating Instructions 24V ACDC a an A AA SS S se 13 Bis Steuerungskategorie 4 Up to control category 4 24V AC DC S33 S34 dG AX S21 S22 S S2 13 23 Bis Steuerungskategorie 4 Up to control category 4 Subject to technical modifications all information are supplied without liability Technische Anderungen vorbehalten alle Angaben ohne Gew hr R 1 I Beispiel 5 Zweikanalige Schutzt r berwach
18. und wire has to be connected to S21 Dual channel The supply voltage has to be connected to the terminals A1 and A2 cables Ausgabedatum Date of issue 21 06 2005 Seite Page 5 von of 9 Dokument Document 0800000434_01 doc Stand Updated 1 Mittlg Published 0368 05 Bernstein AG Tieloser Weg 6 D 32457 Porta Westfalica www bernstein ag de Vorlage Template 0850174292 Orig 2 Bedienungs und Montageanleitung Installation and Operating Instructions Erdschluss bei AC DC Variante mit elektr Sicherung Earth fault AC DC version with electronic fuse protection Fehlfunktion der Kontakte Contact malfunction Nur eine oder keine LED brennt Only one or no LED illuminates Subject to technical modifications all information are supplied without liability Technische nderungen vorbehalten alle Angaben ohne Gew hr Wartung und Reparatur Das Sicherheitsrelais arbeitet wartungs frei Eine Reparatur durch den Anwender ist nicht zul ssig Zum Austausch des Ger tes empfehlen wir die Kabel 1 zu 1 abzuschrauben und an das Austauschger t anzuschrauben 1 Kabel abschrauben und an dem Aus tauschger t anschrauben 2 Defektes Ger t von der Hutschiene nehmen 3 Austauschger t auf Hutschiene mon tieren BERNSTEIN safe solutions Maintenance and repair The safety relay operates maintenance free Any repair work carried out by the user is not permitted For exchange o
19. ung mit Querschlusssicher heit Werden die Schutzt rschalter S1 und S2 geschlossen bleiben die Ausgangskon takte unver ndert Erst mit Freigabe wird das Ger t aktiviert Die Kontakte13 14 23 24 schlie en Beim ffnen des Schutzt rtasters fallen die Kontakte un verz gert in ihre Grundstellung zur ck Beispiel 6 Zweikanalige Schutzt r berwachung mit automatischer Akti vierung und Querschlusssicherheit In diesem Beispiel erfolgt die Aktivierung des Ger tes automatisch da S33 und S34 berbr ckt sind Werden die Schutz t rschalter geschlossen schlie en die Kontakte 13 14 23 24 und 33 34 Beim ffnen der Schutzt rschalter fallen die Kontakte unverz gert in ihre Grundstel lung zur ck Der automatische Start erfolgt schon beim Anlegen der Versorgungsspan nung Verdrahtungshinweis f r die Ausgangs klemmen 13 14 23 24 33 34 und 41 42 Es sollte die Spannung L Leiter bzw 24V DC und nicht NULL ber die Aus g nge geschaltet werden um Erd Mas seschl sse erkennbar zu machen Zur Schonung der Kontakte empfehlen wir ein RC Glied parallel zum Verbrau cher zu schalten Erg nzender Hinweis Bei entsprechender Verdrahtung nach Applikationsbeispiel 1 und 4 muss durch den Anwender eine Anbindung an die Maschinensteuerung f r die zyklische Testung erfolgen BERNSTEIN safe solutions Example 5 Dual channel safety guard monitoring with opposite polarity be tween channels If
20. ung des Ger tes f hren Montieren Sie das Ger t in einem staub und feuchtigkeitsgesch tzten Geh use Staub und Feuchtigkeit k nnen zu Funktionsst rungen f h ren Sorgen Sie f r eine ausreichende Schutzbeschaltung bei kapazitiven und induktiven Lasten an den Aus gangskontakten n regelm igen Zeitabst nden sollte das NOT AUS Relais ausgel st wer den und auf richtige Funktion gepr ft werden mindestens jedes halbe Jahr oder im Wartungszyklus der Anlage BERNSTEIN safe solutions Safety instructions The safety relay SCR 4 is determined for the use in Single and dual channel control cir cuits for monitoring EMERGENCY STOP devices or safety guards without monitoring the START button Personnel protection and the protection of goods are no longer guaranteed if the safety relay is not applied according to its intended use Please strictly note the following points The device shall only be installed and operated by persons who are familiar with the regulations for occu pational safety and accident preven tion Electric work shall only be carried out by qualified personnel Follow the applicable regulations in particular regarding the protective measures Repair work and especially opening the enclosure may only be carried out by the manufacturer or an author ized representative Otherwise any guarantee is void Avoid mechanical vibrations during transport and o

Download Pdf Manuals

image

Related Search

Related Contents

Ninestar NH-R8728CMY ink cartridge  EVGA e-GeForce 8800 GTS SSC NVIDIA GeForce 8800 GTS  Minimum SNPs version 2043 user manual  子どもの命を守るチャイルドシート 子どもの命を守る  Manual do utilizador FLIR ix series  Bushnell 98-0917/04-09 Binoculars User Manual  Transmissor por Radar de Ondas Guiadas  Samsung SF-650 用戶手冊  Samsung T220P Instrukcja obsługi  Manual de Utilização  