1. Saunders E m EC Actuators Limit Open Travel Stop Operating Instructions E Diaphragm Valves 1 Unscrew the plastic indicator cover 1 4 Rotate the adjustment indicator 3 to by rotating in an anti clockwise the desired travel and hold firmly with direction the correct spanner 2 Using an appropriate spanner hold 5 Rotate the seal locknut 2 clockwise adjustment indicator 3 firmly in until it is seated on the adjustment position indicator 3 and lock them into E position Once tightening torque has 3 Using an appropriate spanner unwind been applied the sealing element is the seal locknut 2 by rotating this in engaged an anti clockwise direction this disengages the locknut sealing 6 Replace the plastic indicator cover 1 element by rotating it in a clockwise direction onto the limit stop indicator 4 M4 thread 10mm on DN15 DN20 amp DN25 amp 16mm on DN40 amp DN50 Crane Process Flow Technologies Ltd Grange Road Cwmbran Gwent UK NP44 3XX Tel 44 0 1633 486666 Fax 44 0 1633 486777 C RA N E e mail technical sales craneflow com www saundersvalves com HC4 135 01 06 04