MOVITRAC® B - Compact Operating Instruction - SEW

image

Contents

1. 37 F102 oil 9 37 F103 oil 37 F104 oil ageing overtemperature 37 F105 oil ageing ready signal 37 F106 brake 37 F11 Overtemperature 35 F110 error Ex e 37 F111 System bus SBus error 37 F116 Timeout MOVI PLC 37 F17 F24 system 35 F25 EEPROM sue uda 35 F26 External 35 F31 TF TH sensor tripped 35 F32 IPOS index 35 F34 Ramp 35 F35 operating mode Ex e protection 35 F36 Option 35 F37 System Watchdog 35 F38 System 36 F43 RS485 36 F44 Unit utilization 36 F45 36 F47 System bus 1 timeout
2. 12 Notes Designation the documentation 4 Operating mode VEC 18 Operating mode 18 Other applicable publications 8 P Parameter list cccecceceeeeeeeeeeeeeeeeeeneeeeees 20 Publications applicable 8 R Repair service 38 Return code 19 Parameter lock active 31 20 Factory setting in progress 31 23 Option card missing 31 27 Option card 31 28 Controller inhibit required 31 29 Invalid value for parameter 31 32 Enable cte t etie 31 34 Error during execution 31 38 FBG11B incorrect data set 31 Return codes ssssssssssesseeenne 31 S Safety notes eet detested 6 Designation in the documentation 4 Structure of the embedded safety notes 5 Structure of the section related safety notes 4 Section related safety notes 4 Signal words in the safety 4 Speed Manual sett
3. 34 Error in sequence Error while saving in FBG11B Startup not performed with FBG Perform startup with MotionStudio or select a new motor 38 FBG11B incorrect data set Stored data set does not match the unit Compact Operating Instructions MOVITRAC B 6 31 32 e AS lt Operation i Status displays 6 2 Status displays 6 2 1 Basic unit keypad FBG11B The status displays on the unit are as follows State Display optionally with Basic unit status LED flash Unit status high FBG11B key pad code byte in status word 1 ENABLE Speed Constant green light 4 ENABLE at current limit Speed flashes Rapid green flashing CURRENT AT STAND dc Slow green flashing 3 STILL NO ENABLE Stop Constant yellow light 2 FACTORY SETTING SEt Rapid yellow flashing 8 CONTROL INHIBIT oFF Rapid yellow flashing 1 24 V operation 24U flashing Slow yellow flashing 0 SAFE STOP U flashing or 24U flashing Slow yellow flashing 17 FBG manual mode active or inverter stopped using STOP button FGB manual operation sym bol or stop is flashing Yellow on long off briefly Timeout Errors 43 47 Flashing green yellow Copy Error 97 Flashing red yellow System error Error 10 17 24 25 32 Constant red light 37 138 1 45 1 77 80 94 Overvoltage phase failure Errors 4 6 7 Slow red flashing Overload Errors 1 3 11 44 84 Rapid red flashi
4. eres 36 F77 IPOS control word 36 F80 RAM test cien eds 36 F81 Start 36 F82 Open 36 F84 motor 36 F97 Copy 36 F98 CRC Error Flash 36 eii e et stent ete 34 39 40 Index F Fault F01 Overcurrent sss 34 Ground fault 34 F113 Wire breakage analog input 37 F94 EEPROM 36 FBG11B keypad Startup ati Ae E e 17 Status of binary inputs outputs 33 G Group drive mtm dan edis 19 K Keypad FBG11B Ola MU Pes is oe tonne eee ia 17 Status 32 L LED NaS Codes icr tee es 32 M Manual operation FBG11B 16 Manual speed control module 16 Maximum 16 Minimum 16 Multi motor drive cccccecceeeeeeseeeeeeeeceeeeeeeeeees 19 N
5. Drive Technology Drive Automation System Integration Service UUM AA OAT A A EURODRIVE Compact Operating Instructions MOVITRAC B Edition 10 2011 19363613 EN SEW EURODRIVE Driving the world Lu i25 Contents Contents 1 General Information idend dete etre nite red ioa ker c 4 1 14 Scope of this documentation ssssssssssssssseeeeeee 4 1 2 Structure of the safety 4 2 Safety Notes 2 aa ie en etal Ga Ree 6 2 1 Preliminary information 6 2 2 General information 6 2 9 Target group i deed c ieai a Aet iced eda led 7 2 4 Designated usesis iini asia aate 7 2 5 Applicable documentation ssssssssssseeenenenneee 8 2 6 Transport storage eke ee Pad ee Re eee ee Le e a 8 2T JInstallatlOn iere eret tear at ditate 9 2 8 Electrical connection eene 9 2 9 Safe disconnection one eee t cette te ee 9 2 10 Operatlori s ior cest ti e ee etu eet are i vert et bL ue 10 2 11 Unit temperature ssssssssssesssssee eene nennen nnne 10 3 Unit Designation Nameplate eene nennen 11 3 1 desino
6. CCW stop _ DI 2_ 3 r Binary Enable stop t __ 0103 4 outputs n11 n21 4 04 5 nig ntt nt2 DI 5TF 6l Supply voltage for TF TH VOTF 7 H 2 24V input output 24VIO 8 4 Reference can be switched off with P808 GND 9 i binary outputs Reference potential binary signals H X13 EN Reference potential GND 1 i A Jon AC 3 Brake released 0002 2 l Ready for operations DO 3 3 i i i Reference potential GND 4 bord Relay contact malfunction DO 1 C 5 i i Relay NO DO 1 NO 6 i i X17 Relay NC DO 1 NC 7 MM X17 Safe stop Ox x bd i 3 x 400 V ZASS iG 5 5 75 kW standard ggz QO 8 x 400 V 9 II 0 55 4 0 kW MCO7B S0 N O x2 3x230 V X2 PE U V R R 3 7 30 kW standard n 3 x 230 V 1 i 0 55 2 2 kW 7 50 Section Brake rectifier connection IU Section BW BW T BW P brake rectifier connection Factory setting 1 In sizes 1 2S and 2 there is no PE connection next to the power supply connection terminals and motor connection terminals X1 X2 Use the PE terminal next to the DC link connection X4 only size 1 5 For size 0 the plate is the PE connection 2 The MCO7B SO unit type must always be supplied with external voltage X4 is only available in sizes 1 5 From size 3 onwards there are two additional
7. Extend deceleration ramps Braking resistor circuit inter Check supply cable to the brak rupted ing resistor Short circuit in the braking resis Rectify the short circuit tor circuit Brake resistance too high e Check technical data of braking resistor Brake chopper defective Replace the MOVITRAC B Ground fault Eliminate ground fault 06 Mains phase Immediate switch Phase failure e Check the line cable failure off with inhibit only 3 with 3 phase Supply voltage too low Check the supply voltage inverter 07 DC link over Immediate switch DC link voltage too high Extend deceleration ramps voltage off with inhibit e Check supply cable to the brak ing resistor e Check technical data of braking resistor Ground fault Eliminate ground fault 08 Speed monitor Immediate switch Current controller works at the set ing off with inhibit limit due to Mechanical overload Reduce load Check current limitation Extend deceleration ramps Increase set deceleration time P501 Phase failure in supply system Check line phases Phase failure in motor e Check motor cable and motor Maximum speed for VFC oper Reduce maximum speed ating modes exceeded 09 Startup Immediate switch Inverter not started yet Start up the inverter off with inhibit Unknown motor selected Select another motor 10 IPOS ILLOP Stop with inhibit Wrong command during pro e Check the program
8. Please also observe the supplementary safety notes in the individual sections of this publication General information During operation frequency inverters can have live bare parts according to their degree of protection Severe or fatal injuries All work related to transportation storage setup mounting connection startup maintenance and repair may only be carried out by qualified personnel in strict ob servance of Therelevant detailed operating instructions The warning and safety signs on the motor gearmotor All other project planning documents operating instructions and wiring diagrams related to the drive The specific regulations and requirements for the system The national regional regulations governing safety and the prevention of acci dents Never install damaged products Submit a complaint to the shipping company immediately in the event of damage Removing covers without authorization improper use as well as incorrect installation or operation may result in severe injuries to persons or damage to property This document provides further information Compact Operating Instructions MOVITRAC B Safety Notes Target group 2 3 2 4 Target group Any mechanical work may only be performed by adequately qualified personnel Quali fied personnel in this context are persons who are familiar with the setup mechanical installation trouble shooting and maintenance for
9. 8336 Binary input 0102 0 No function assignment 1 Enable stop factory setting DIO3 602 8337 Binary input DIO3 2 CW stop assignment 3 CCW stop factory setting 0102 603 8338 Binary input DIO4 4 n11 n21 factory setting D104 Short assignment 5 n12 n22 factory setting 0105 604 8339 Binary input 0105 n13 11 n12 assignment 6 Changing the fixed setpoint 608 8844 Binary input DIOO T Parameter set switchover assignment 8 Ramp switchover 61 Binary inputs 9 Motor potentiometer up option 10 Motor potentiometer down 11 External error 919 99340 12 Error reset factory setting 0100 611 8341 Bi IRSUFDH 19 Slave free running 20 Setpoint acceptance active 26 TF signal only with 0105 612 EUNT nete Binary input 0112 27 Vibration warning assignment 28 Vibration error 613 8343 Binary input 0113 29 Brake wear assignment 30 Controller inhibit 614 8344 Binary input 0114 33 Oil aging warning assignment 34 Oil aging error 615 8345 Binary input DI15 35 Oil aging overtemperature assignment 36 Oil aging ready 616 8346 Binary input DI16 assignment Compact Operating Instructions MOVITRAC B Startup Parameter list ago No FBG Index dec Name Range factory setting Display MOVITOOLS MotionStudio 62 Binary outputs 620 621 622 8350 Binary output DOO1 assignmen
10. Brake lining worn Replace brake lining see Motors operating instructions 110 Ex e protection Emergency stop Duration of operation below 5 e Check configuration Hz exceeded Shorten duration of operation below 5 Hz 111 System bus This error number signals the EtherCAT or fieldbus mas Check FSE24B plug connection SBus error ter that the communication between FSE24B and MOVITRAC B is interrupted MOVITRAC B would detect error 47 113 Analog input Programmable Al1 analog input open circuit Check wiring open circuit 116 Error application module Suberror 14 Encoder error 29 Limit switch contacted 42 Lag error 78 Software limit switch reached 1 Change parameters P500 P502 and P501 P503 to set the speed monitoring The sagging of hoists cannot be avoided safely when monitoring is deactivated or the delay time is set too long 2 Noreset required error message disappears after communication is reestablished Compact Operating Instructions MOVITRAC B 37 7 38 e S 4 Service List of Errors 20 SEW electronics service 7 2 SEW electronics service 7 2 1 Hotline Call the Drive Service Hotline to talk to an SEW EURODRIVE service specialist on 365 days a year 24 hours a day Simply dial the prefix 01805 and then enter the key combination SEWHELP Or simply dial 01805 739 4357 7 2 2 Sending a unit in for repair Consult SEW Electronics Service i
11. main menu level by pressing the OUT button You can then perform startup only with motor parameter set 1 INFORMATION The SEW motor startup is designed for 4 pole motors It may be useful to start up 2 pole or 6 pole SEW motors as non SEW motors 5 3 3 Operating mode V f The default setting for the operating mode is V f Use this operating mode if you have no particular speed quality requirements and for applications that require a maximum out put frequency 150 Hz 5 3 4 Operating mode Start up the inverter in or amp DC brake operating mode for the following require ments High torque Continuous duty at low frequencies Accurate slip compensation More dynamic behavior For this purpose you will have to choose the VFC or VFC amp DC brake operating modes from P07 at startup 18 Compact Operating Instructions MOVITRAC B Startup go Startup using the FBG11B keypad 5 3 5 Multi motor drive startup Multi motor drives are mechanically coupled to each other e g chain drive with multiple motors Observe the notes in the MOVIDRIVE Multi Motor Drives manual 5 3 6 Group drive startup Group drives are mechanically decoupled from each other e g different conveyor belts In this operating mode the inverter operates without slip compensation and with a constant V f ratio Observe the notes in the MOVIDRIVE Multi Motor Drives manual 5 3 7 Startup with
12. operated in climate class 3K3 to EN 60721 3 3 Usein non stationary applications which are subject to mechanical vibration and im pact loads in excess of the requirements in EN 61800 5 1 onnection Observe the applicable national accident prevention guidelines when working on live frequency inverters e g BGV A3 for Germany During installation observe the specifications regarding cable cross sections fusing and protective conductor connection This publication contains additional information In this documentation you will find notes on EMC compliant installation such as shield ing grounding arrangement of filters and routing of lines The manufacturer of the sys tem or machine is responsible for maintaining the limits established by EMC legislation Protective measures and protection devices must comply with the regulations in force e g EN 60204 or EN 61800 5 1 Ground the unit Safe disconnection The unit meets all requirements for safe disconnection of power and electronic connec tions in accordance with EN 61800 5 1 All connected circuits must also satisfy the re quirements for safe disconnection Compact Operating Instructions MOVITRAC B 10 Safety Notes Operation 2 10 Operation Systems with integrated frequency inverters must be equipped with additional monitor ing and protection devices as applicable according to the relevant safety guidelines and regulations such as legislation gove
13. system bus connection timeout inhibit system bus Check P808 Check voltage supply of FSE24B e Check EtherCAT communica tion with connected FSE24B 77 IPOS control Stop with inhibit e System malfunction Contact SEW Service word 80 RAM test Immediate discon Internal unit error RAM defec Contact SEW Service nection tive 81 Start condition Immediate switch Only in hoist operating off with inhibit mode The motor could not be supplied with the correct amount of current during the pre magnetizing time Rated motor power too smallin Check connection between relation to rated inverter power inverter and motor Check startup data and perform new startup if necessary Motor cable cross section too e Check cross section of motor small cable and increase if necessary 82 Open output Immediate switch Only in VFC hoist operating off with inhibit mode e 2orall output phases inter Check connection between rupted inverter and motor Rated motor power too small in Check startup data and perform relation to rated inverter power new startup if necessary 84 Motor protec Stop with inhibit Motor utilization too high e Check P345 P346 Iy UL moni tion toring Reduce load Extend ramps Longerrest periods 94 EEPROM Immediate switch Defective EEPROM Contact SEW Service checksum off with inhibit 97 Copy error Immediate switch Parameter module is removed Prior to acknowledgement
14. 0 701 8574 8575 Operating mode 1 2 VFC VFC amp Hoist VFC amp DC braking VFC amp flying start function V f characteristic curve V f amp DC braking SIS N gt AONO Compact Operating Instructions MOVITRAC B 5 9 27 5 28 nr Startup Parameter list No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 71 Standstill current 1 2 710 711 8576 Standstill current 0 50 Imot Lang 8577 1 2 72 Setpoint stop function 1 2 720 723 8578 Setpoint stop func oFF Off 8581 tion 1 2 on On 7211724 8579 Stop setpoint1 2 0 30 500 rpm Lani 8582 7221725 8580 Start offset 1 2 0 30 500 rpm 8583 73 Brake function 1 2 731 734 8749 Brake release time 0 2s 8750 1 2 732 735 tonb 8585 Brake application 0 25 8587 time 1 2 74 Speed skip function 740 742 8588 skip window center 0 1500 5000 rpm 8590 1 2 741 743 tanb 8589 skip width 0 300 rpm 8591 1 2 75 Master slave function 750 8592 Slave setpoint 0 Master slave off 1 Speed RS485 2 Speed SBus Lonk 3 Speed RS485 SBus 751 8593 Scaling slave set 1 00 point 76 Manual operation 760 8798 Lock RUN STOP oFF Off Lent RESET keys on On 77 Energy saving function 77
15. 0 8925 Energy saving func oFF Off Lonk tion on On 8 Unit functions on FBG only parameter set 1 80 Setup 800 Quick menu long Short 801 DBG language 802 8594 Factory setting No No Shark Hours Standard ALL Delivery state NEMA Delivery state NEMA 803 8595 Parameter lock oFF Off on On 804 8596 Reset statistics data No action Error memory 805 8660 Rated line voltage 50 500 V Compact Operating Instructions MOVITRAC B Startup Parameter list ago No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 806 Copy DBG Yes MOVITRAC B No 807 Copy MOVITRAC Yes B DBG No 808 10204 3 24 V output voltage Off Off On On 809 10204 1 IPOS enable Off On 81 Serial communication 810 8597 RS485 address 0 99 811 8598 RS485 group 100 199 address 812 8599 RS485 Timeout 0 650s interval 819 8606 Fieldbus timeout Fieldbus timeout interval display interval 82 Brake operation 1 2 820 821 8607 4 quadrant opera oFF Off L 8608 tion 1 2 on On 83 Error responses 830 8609 Response terminal 2 Immediate stop malfunction external error 4 Rapid stop Malfunction Factory setting for 833 8612 Response timeout 7 P830 Lonk RS485 Rapid stop Warning Factory setting for P833 836 8615 Response to SBus F836 timeout 84
16. 022 2 B 1 4 O0 T Design Design Quadrants Connection type Radio interfer ence suppres sion Supply voltage Recommended motor power Version B T Technology unit L Paint partially coated circuit boards S SBus address 1 00 Standard SO Safe stop 4 4Q with brake chop per 3 3 phase 1 1 phase 0 No radio interference suppression A Radio interference suppression C2 B Radio interference suppression C1 2 AC 200 240 V 5 AC 380 500 V 0022 2 2 kW Series and generation MOVITRAC type Compact Operating Instructions MOVITRAC B 11 12 3 2 Unit Designation Nameplate Nameplate Nameplate The following figure shows a nameplate Eingangs Input Made in Geraany i TELL TT MC07B0005 2B1 4 00 FSC118 508 01 1359334901 0001 10 Auageng Output U 1x200 240V U J 0 UN Ws D 76646 Bruchsal _ f 0 600Mz Unr ichter 1 5A 230V 1 3 38 AC 230V MOS eo MOVITRAC B T 1D0 50 IP 20 0 5544 0 7 n LOOO1 ii 3185547659 Input U Rated line voltage Rated line current 100 operation f Nominal line frequency Output U Output voltage 100 operation l Nominal output current 100 operation f Output frequency T Ambient temperature P motor Recommended motor power 100 operation The unit status is indicated above the lower barcode It document
17. 11 3 2 Nameplate as cenae c edenda ce ed geh ar aod uae ae es 12 MED ETCIEU DL RETE 13 4 1 Wiring diagram seni e t ae et UO EET en ieee 14 MEE LCS 15 5 1 Startup with factory setting brief description 15 5 2 Manual operation with FBG11B speed control 16 5 3 Startup using the FBG11B keypad 17 5 4 Parameter 6 occ roi abr e Hatte Nae tede ebbe tdeo tee pad itta 20 6 ice De 31 6 1 Return codes r 19 38 nennen 31 6 2 Status displays iia ite p RE EH HERE LUE vies 32 7 Service l List of Error S nee ei eee car e e ora inaona KR AeKa aA 34 7 1 Errorlist F 00 13 eer at ener nee 34 7 2 SEW electronics seinieni anaa a ea a a a aaaea 38 a dE EP CE 39 Compact Operating Instructions MOVITRAC B General Information Scope of this documentation 1 General Information 1 1 Scope of this documentation This documentation comprises the general safety notes and a selected information re garding the device Please note that this documentation does not replace the detailed operating instruc tions Read the detailed operating instructions before you start working with the devic
18. 42 8535 Motor protection 2 OFF ON ASYNCHRONOUS ON SERVO 343 8536 Cooling type 2 FAN COOLED FORCED COOLING 345 346 9114 Ij UL monitoring 1 0 1 500A Lani 9115 2 24 Compact Operating Instructions MOVITRAC B Startup Parameter list ago No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 4 Reference messages 40 Speed reference signal 400 8539 Speed reference 0 750 5000 rpm value 401 8540 Hysteresis 0 100 500 rpm 402 Loni 8541 Deceleration time 0 1 9s 403 8542 Message 1 if 0 n lt 1 n gt Nref 43 Current reference signal 430 8550 Current reference 0 100 150 Iu value 431 8551 Hysteresis 0 5 30 IN 432 Loni 8552 Deceleration time 0 1 9s 433 8553 Signal 1 when 0 L5 leer 1 gt 44 Imax Signal 440 8554 Hysteresis 0 5 50 IN 441 8555 Deceleration time 0 1 9s 442 tonb 8556 Signal 1 when 0 L lt Imax 1 gt Imax 45 PI controller reference message 450 8813 PI actual value ref 0 0 100 0 96 erence 451 Loni 8796 Message 1 if 0 PI Actual value PI ref 1 PI Actual value gt PI ref 5 Control functions on FBG only parameter set 1 50 Speed monitoring 1 2 500 502 8557 Speed monitoring 1 0 O
19. 62 Front module 073 8364 Firmware front module 076 8300 Basic unit firmware Part number and version 077 DBG firmware Only in DBG60B 08 Error memory 080 084 8366 Error 1 0 t 4 Error Background information for previous errors Lan amp 8370 code Compact Operating Instructions MOVITRAC B 5 9 21 5 22 ago Startup Parameter list No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 09 Bus diagnostics 090 8451 PD configuration 091 8452 Fieldbus type 092 8453 Fieldbus baud rate 093 8454 Fieldbus address 094 8455 PO 1 setpoint hex 095 8456 PO 2 setpoint hex 096 tenb 8457 PO 3 setpoint hex 097 8458 PI 1 actual value hex 098 8459 PI 2 actual value hex 099 8460 PI 3 actual value hex 10497 1 Bus status 10497 3 Device identification 1 Setpoints ramp generators on FBG only parameter set 1 10 Setpoint selection frequency input 100 8461 Setpoint source 0 Bipolar fixed setpoint 1 Unipolar fixed setpoint 2 RS485 fixed setpoint 4 Motor potentiometer fixed setpoint 6 Fixed setpoint 11 7 Fixed setpoint Al1 8 MASTER SBus1 9 MASTER RS485 10 SBus 1 fixed setpoint 11 Frequency setpoint input fixed setpoint 14 Bipolar Al2 Fixed setpoint 101 8462 Contro
20. MOVITRAC B operating instructions and limits the ap plication notes according to the following information It can only be used in conjunction with the following publications MOVITRAC B compact operating instructions MOVITRAC B communication manual The respective manual of the used option card Transport storage Inspect the shipment for any damage that may have occurred in transit as soon as you receive the delivery Inform the shipping company immediately It may be necessary to preclude startup Observe the climate conditions according to chapter General techni cal data Compact Operating Instructions MOVITRAC B Safety Notes Installation 2 7 2 8 2 9 Installation Electrical c The units must be installed and cooled according to the regulations and specifications in this documentation Protect the frequency inverters from excessive strain Do not twist any components and do not modify the insulation spaces Do not touch any electronic components or con tacts Frequency inverters contain components that can easily be damaged by electrostatic energy and improper handling Electric components must not be mechanically damaged or destroyed The following applications are prohibited unless the unit is explicitly designed for such use Usein potentially explosive atmospheres Usein areas exposed to harmful oils acids gases vapors dust radiation etc fre quency inverter may only be
21. No function 1 0 10 V setpoint 2 0 10 V current limit 121 8811 Addition FBG 0 Off ae speed control mod 1 2 On without fixed setpoint 122 8799 Direction of rotation 0 Unipolar CW FBG manual opera 1 Unipolar CCW tion 2 Bipolar CW and CCW 126 10247 1 Al2 char curvex1 100 96 0 100 C10 V 0 10 V 127 10247 2 AI2 char curve y1 100 0 100 Nmax 0 Nmax 0 Imax 128 tanb 10247 3 Al2 char curve 2 100 0 100 C10 V 0 10 V 129 10247 4 Al2 char curve y2 100 0 100 Nmax 0 O max 0 Imax 13 14 Speed ramps 1 2 130 140 8807 Ramp 111 021 up 0 1 2 2000 s 9264 131 141 z 8808 Ramp t11 t21 0 1 2 2000 s 9265 down 134 144 8474 Ramp t12 t22 0 1 10 2000 s 8482 135 145 8475 S pattern 112 t22 0 Off 8483 1 Weak 2 Medium Lonk 3 Strong 136 146 8476 Stop ramp t13 t23 0 1 2 20s 8484 139 149 8928 Ramp monitoring 1 0 YES 8929 12 1 15 Motor potentiometer 150 8809 Ramp t3 up down 0 2 20 50 152 Lang 8488 Save last setpoint oFF Off on On Compact Operating Instructions MOVITRAC B 9 23 Startup Parameter list ago No FBG Index Name Ran
22. PE ter minals 14 Compact Operating Instructions MOVITRAC B Startup 5 Startup with factory setting brief description 5 Startup 5 1 Startup with factory setting brief description You can directly connect the MOVITRAC B frequency motor to a motor with the same power rating For example A 1 5 kW 2 0 HP motor can be connected directly to a MCO7B0015 5 1 4 Procedure 1 Connect the motor to MOVITRAC B terminal X2 2 You have the option of connecting a braking resistor terminal X2 X3 3 The following signal terminals must be controlled with your control system Enable 0123 Asrequired CW STOP DI 1 or CCW STOP DI 2 Setpoint Analog input X10 and or DI 4 11 150 rpm and or DI 5 n12 750 rpm and or 0104 DI 5 n13 1500 rpm For brakemotors DO 2 brake control via brake rectifiers 4 You have the option of connecting the following signal terminals 0100 error reset malfunction designed as a relay contact DO 3 ready 5 Check the controller for the required functionality 6 Connect the frequency inverter to the mains X1 5 1 2 Notes Signal terminal functions and setpoint settings can be modified using the FBG11B key pad or a PC A PC connection requires the FSC11B front option or one of the following interface adapters UWS21B UWS11A USB11A Compact Operating Instructions MOVITRAC B 15 5 16 gu 5 2 Startup Manual opera
23. Reset behavior 840 8617 Manual reset Yes No 841 8618 Auto reset Off Off 842 8619 Restart time 1 3 30s 85 Scaling actual speed value 850 8747 Scaling factor 1 65535 can be set with SHELL only numerator 851 8748 Scaling factor 1 65535 can be set with SHELL only denominator 852 Lonh 8772 User unit Text 8773 853 9312 Scaled speed FBG Speed Alo Scaled speed Compact Operating Instructions MOVITRAC B 5 9 29 5 30 qv Startup Parameter list No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 86 Modulation 1 2 860 861 8620 PWM frequency 4 4 kHz 8621 1 2 8 8 kHz 12 12 kHz Lond 16 16 kHz 862 863 8751 PWM fix 1 2 on On 8752 OFF Off 87 Process data parameter setting 870 8304 Setpoint descrip 0 No function factory setting P872 tion PO1 1 Setpoint speed factory setting P871 871 8305 Setpoint descrip 5 Max speed tion PO2 8 Ramp 872 8306 Setpoint descrip 9 Control word 1 factory setting P870 tion PO3 10 Control word 2 11 Setpoint speed 12 IPOS PO data 13 Pl controller setpoint 96 873 tonb 8307 Actual value 0 No function description PI1 1 Actual speed factory setting P874 874 8308 Actual value 2 Output current factory setting P875 description PI2 3 Active current 875 8309 Actu
24. With IPOS only gram execution e Incorrect conditions during pro Check program run gram execution Function does not exist is not Use another function implemented in the inverter Compact Operating Instructions MOVITRAC B Service List of Errors M VR Error list F 00 F113 N Y 7 No Designation Response Possible cause Measure 11 Overtempera Stop with inhibit Thermal overload of inverter Reduce load and or ensure ade ture quate cooling Ifa braking resistor is integrated in the heat sink Install braking resistor externally 17 System mal Immediate switch Inverter electronics is faulty Check grounding and shielding function off with inhibit possibly due to EMC influence and improve if necessary 24 e Contact SEW Service for advice if this error reoccurs 25 EEPROM Stop with inhibit Error while accessing EEPROM Restore factory settings per form reset and reset parame ters Consult SEW Service if the error reoccurs 26 External termi Programmable e Read in external error signal via Eliminate respective cause nal programmable input reprogram terminal if necessary 31 TF TH sensor Stop without inhibit Motor too hot TF sensor has Let motor cool off and reset tripped Ready signal tripped error is maintained TF sensor of motor not con Check connections links nect
25. al value 6 Status word 1 factory setting P873 description PI3 7 Status word 2 8 Actual speed 9 IPOS PI DATA 10 PI controller actual value 96 876 8622 PO data enable No No Lonk Yes Yes 88 Serial communication SBus 880 8937 SBus protocol 0 MOVILINK tai 1 CANopen 881 i 8600 SBus address 0 63 882 8601 SBus group 0 63 address 883 8602 SBus timeout inter 0 650 s val 884 8603 SBus baud rate 125 125 kBd vu 250 250 kBd Lene 500 500 kBd 1000 1 Mbaud 886 8989 CANopen address 1 2 127 Compact Operating Instructions MOVITRAC B Operation go 6 Operation 6 1 Return codes r 19 r 38 Return codes when entering editing a unit parameter in the FBG11B Return codes r 19 r 38 No Designation Meaning 18 Only read access Parameter cannot be changed 19 Parameter lock activated Parameters cannot be changed 20 Factory setting in progress Parameters cannot be changed 23 Option card missing The option card required for the function is missing 27 Option card missing The option card required for the function is missing 28 Controller inhibit required Controller inhibit required 29 Invalid value for parameter Invalid value for parameter FGB manual operation selection invalid as PC is in active manual operation 32 Enabled You cannot perform this function in ENABLED status
26. d source of danger Possible consequence s if disregarded e Measure s to prevent the danger Compact Operating Instructions MOVITRAC B General Information Structure of the safety notes 1 2 3 Structure of the embedded safety notes Embedded safety notes are directly integrated in the instructions just before the descrip tion of the dangerous action This is the formal structure of an embedded safety note A SIGNAL WORD Nature and source of hazard Possible consequence s if disregarded Measure s to prevent the danger Compact Operating Instructions MOVITRAC B 2 2 1 2 2 Safety Notes Preliminary information Safety Notes The following basic safety notes must be read carefully to prevent injury to persons and damage to property The operator must ensure that the basic safety notes are read and adhered to Make sure that persons responsible for the plant and its operation as well as persons who work independently on the unit have read through the operating instruc tions carefully and understood them If you are unclear about any of the information in this documentation or if you require further information please contact SEW EURO DRIVE Preliminary information The following safety notes predominantly refer to the use of frequency inverters Addi tionally when using drives with motors or gearmotors observe the corresponding safety notes in the respective operating instructions
27. e Observe the information instructions and notes in the detailed operating instructions This is essential for fault free operation of the unit and fulfillment of any rights to claim under warranty The enclosed CD or DVD contains PDF files of the additional operating instructions as well as further documentation regarding the device All technical documentation from SEW EURODRIVE is available as individual PDF files via the SEW EURODRIVE website www sew eurodrive de 1 2 Structure of the safety notes 1 2 1 Meaning of the signal words The following table shows the grading and meaning of the signal words for safety notes notes on potential risks of damage to property and other notes Signal word Meaning Consequences if disregarded A DANGER Imminent danger Severe or fatal injuries WARNING Possible dangerous situation Severe or fatal injuries CAUTION Possible dangerous situation Minor injuries NOTICE Possible damage to property Damage to the drive system or its envi ronment INFORMATION Useful information or tip Simpli fies the handling of the drive system 1 2 2 Structure of the section related safety notes Section related safety notes do not apply to a specific action but to several actions per taining to one subject The used symbols indicate either a general or a specific hazard This is the formal structure of a section related safety note SIGNAL WORD Type an
28. ed or connected incorrectly between MOVITRAC B and TF Connection of MOVITRAC B and TF on motor interrupted 32 IPOS index Stop with inhibit Programming principles violated Check user program and correct overflow leading to internal stack over it flow 34 Ramp timeout Immediate switch Set ramp time exceeded Extend the ramp time gib withrinnibit Ifyou remove the inhibit and the Extend the stop ramp time drive exceeds the stop ramp time t13 by a certain time the inverter will signal F34 35 Exe protection Immediate switch Wrong operating mode selected Permitted modes operating mode off with inhibit 6 VEC hoist Incorrect modes Flying start function DC braking Group operation Non permitted parameter set Use parameter set 1 only No Ex e motor started up Startup Ex e motor Incorrect parameterization of Frequency A lt frequency B the frequency points Frequency B lt frequency Incorrect parameterization of Current limit A lt current limit B the current limits Current limit B current limit C 36 Option missing Immediate switch Type of option card not allowed Use correct option card off with inhibit z Setpoint source control signal Set correct setpoint source source or operating mode not Set correct control signal source permitted for this option card Set the correct operating mode Check parameters P120 and P121 R
29. equired option missing Check the following parameters P121 for FBG11B P120 and P642 for FIO12B Front module FIO21B not sup Set P808 to On or supply plied basic unit with external 24 V 37 System watch Immediate switch Fault system software Check grounding and shielding dog off with inhibit sequence and improve if necessary Contact SEW Service for advice if this error reoccurs Compact Operating Instructions MOVITRAC B 35 36 e ww Service List of Errors A Error list F 00 F113 No Designation Response Possible cause Measure 38 System soft Immediate switch System malfunction e Check grounding and shielding ware off with inhibit and improve if necessary Contact SEW Service for advice if this error reoccurs 43 RS485 timeout Stop without lock Connection between inverter Check connection between ing and PC interrupted inverter and PC Communication to FSE24B Check voltage supply interrupted Check P808 44 Unit utilization Immediate switch Unit utilization I x t value Decrease power output off with inhibit exceeded Extend ramps fneither is possible Use a larger inverter 45 Initialization Immediate switch Error during initialization Contact SEW Service off with inhibit 47 System bus 1 Stop without Error during communication via Check
30. eter set set 014 8327 Heat sink tempera C Lont ture 02 Analog setpoints 020 8331 Analog input Al1 V 021 Lang 8332 Analog input Al2 V optional 03 Binary inputs see parameter P60 030 8844 Binary input DIOO Error reset 031 8335 Binary input DIO1 CW STOP fixed assignment 032 8336 Binary input 0102 CCW stop 033 8337 Binary input DIO3 Enable stop 034 8338 Binary input D104 n11 n21 035 8339 Binary input 0105 n12 n22 Compact Operating Instructions MOVITRAC B Startup Parameter list ago No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 039 8334 Binary inputs DIOO Collective display of binary inputs Lon 0105 04 Binary inputs option see parameter P60 040 Binary input DI10 No function 041 Binary input DI11 No function 042 Binary input DI12 No function 043 Binary input DI13 No function 044 Binary input DI14 No function 045 Binary input DI15 No function 046 Binary input DI16 No function 048 8348 Binary inputs DI10 Collective display of binary inputs Lonk DI15 05 Binary outputs see parameter P62 051 8349 Binary output DOO1 Fault 052 8349 Binary output DOO2 Brake released 053 8349 Binary output DOO3 Ready 059 8349 Binary outputs Collective display of binary outputs Lon DO01 0003 07 Unit data 070 8301 Unit type Text 071 8361 Nominal output cur A rent 073 83
31. f you are unable to rectify the error Please always specify the unit status code number when you contact the SEW electron ics service so that our service personnel can assist you more effectively Provide the following information when sending the unit in for repair e Serial number see nameplate Type designation Short description of application application control via terminals or serial Connected motor motor voltage star or delta connection Nature of the fault Accompanying circumstances Your own presumptions as to what has happened Unusual events preceding the problem Compact Operating Instructions MOVITRAC B Index Index C Content of this D Documentation E Electronics service 38 Embedded safety notes Compact Operating Instructions MOVITRAC B Error F04 Brake 34 F06 Mains phase failure 34 F07 DC link overvoltage 34 F08 Speed monitoring 34 FOS st rtupi nee mu rei 34 F10 IPOS ILLOP 34 F100 vibration warning 36 F101 vibration error
32. ff 8559 12 3 Motor regenerative 501 503 tonb 8558 Delay time 1 2 0 1 10s 8560 54 Gear unit motor monitoring 540 9284 Response to drive 1 Display error vibration warning 541 9285 Response to drive 7 Rapid stop warning vibration error 542 9286 Response to oil 1 Display error aging error 543 9287 Response to oil 1 Display error Lonk aging warning 544 9288 Oil aging overtem 1 Display error perature 545 9289 Oil aging ready 1 Display error signal 549 9290 Response to brake 1 Display error wear Compact Operating Instructions MOVITRAC B 5 9 25 Startup Parameter list ago 26 No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 56 Ex e motor current limitation 560 9293 Ex e motor current ON OFF limit ERES 561 9294 Frequency A 0 5 60Hz 562 9295 Current limit A 0 50 150 563 9296 Frequency B 0 10 104 Hz 564 9297 Current limit B 0 80 200 96 565 9298 Frequency C 0 25 104 Hz 566 9299 Current limit 0 100 200 96 567 10247 20 Frequency D 0 50 104 Hz 568 10247 21 Current limit D 0 100 200 96 57 570 10247 22 Frequency E 0 87 104 Hz 571 10247 23 Current limit E 0 100 200 6 Terminal assignment 60 Binary inputs 601
33. ge factory setting dec Display MOVITOOLS MotionStudio 16 17 Fixed setpoints 160 170 8489 Internal setpoint 0 150 5000 rpm 8492 n11 n21 161 171 8490 Internal setpoint 0 750 5000 rpm 8493 n12 22 162 172 8491 Internal setpoint 0 1500 5000 rpm 8494 n13 n23 163 173 f 8814 n11 n21 PI control 0 3 100 96 8817 ler 164 174 8815 n12 n22 PI control 0 15 100 96 8818 ler 165 175 8816 n13 n23 PI control 0 30 100 96 8819 ler 2 Controller parameters 25 PI controller 250 8800 PI controller 0 Off 1 Normal 2 Inverted Lonk 251 8801 PI gain 0 1 64 252 8802 component 0 1 2000s Motor parameters on FBG only parameter set 1 30 31 Limits 1 2 300 310 8515 Start stop speed 1 0 150 rpm 8519 2 301 311 Lonh 8516 Minimum speed 0 15 5500 rpm 8520 1 2 302 312 H 8517 Maximum speed 0 1500 5500 rpm SM 8521 112 303 313 8518 Current limit 1 2 0 150 Lan amp 8522 32 133 Motor adjustment 1 2 320 330 8523 Automatic adjust oFF Off 8528 ment 1 2 on On 321 331 8524 Boost 1 2 0 100 8529 322 1 332 8525 IxR compensation 0 100 Loni 8530 1 2 323 333 8526 Premagnetization 0 2s 8531 time 1 2 324 334 8527 Slip compensation 0 500 rpm 8532 1 2 34 In UL monitoring 340 8533 Motor protection 1 OFF ON ASYNCHRONOUS ON SERVO 341 8534 Cooling type 1 FAN COOLED FORCED COOLING 3
34. ing 16 MaximuM ect ed 16 MIDITIUITIS is Loci oti yr ERROR 16 Speed control module Man al atre orietur dae 16 Startup Brief 15 FBG11B keypad 17 Status displays Basic unit oot ee RU ette aco 32 Keypad nien cae aei tete dea adde 32 LED flash CodeS ci eet cr 32 Status of binary inputs outputs 33 T Type designation 11 U Unit Status x 4er e Aik DR eec a 11 12 Unit status codes 32 V loe is 18 iM 18 Wiring 14 Compact Operating Instructions MOVITRAC SEW EURODRIVE Driving the world B I de 14 EP i S am SEW EURODRIVE Driving the world EURODRIVE SEW EURODRIVE GmbH amp Co KG P O Box 3023 D 76642 Bruchsal Germany Phone 49 7251 75 0 Fax 49 7251 75 1970 sew sew eurodrive com www sew eurodrive com
35. ive 2006 42 EC machine directive observe EN 60204 Startup i e the start of designated use is only permitted under observance of the EMC 2004 108 EC directive The frequency inverters comply with the requirements of the Low Voltage Directive 2006 95 EC The harmonized standards of the EN 61800 5 1 DIN VDE T105 series in connection with EN 60439 1 VDE 0660 part 500 and EN 60146 VDE 0558 are ap plied to these frequency inverters Observe the technical data and the connection requirements specified on the nameplate and the operating instructions Compact Operating Instructions MOVITRAC B 2 4 1 Safety Notes Applicable documentation Safety functions Frequency inverters from SEW EURODRIVE must not perform any safety functions un less the inverters are subordinate to other safety systems Use higher level safety systems to ensure protection of equipment and personnel When using the Safe stop function you must observe the following publications MOVITRAC B functional safety This documentation is available via Documentation Software CAD on the SEW EU RODRIVE web site 2 4 2 Content of this publication 2 5 2 6 This publication contains conditions and amendments related to MOVITRAC B in safety oriented applications The system comprises a frequency inverter with asynchronous motor and safety tested external disconnecting device Applicable documentation This document supplements the
36. l signal 0 Terminals Short POUrCE 1 RS485 3 SBus 1 4 3 wire control 102 8840 Frequency scaling 0 1 10 120 00 kHz 103 10247 15 reference 0 Nmax 1 Nreference 104 10247 10 Setpoint reference 0 3000 6000 rpm Speed Nreference 105 10416 1 Wire breakage 0 No response detection 2 Immediate stop malfunction 4 Rapid stop malfunction 7 Rapid stop warning 106 10247 11 FI1 char curve x1 0 100 107 10247 12 FI1 char curve y1 100 96 0 100 96 108 tenb 10247 13 FI1 char curve x2 0 100 109 10247 14 FI1 char curve y2 100 0 100 96 Compact Operating Instructions MOVITRAC B Startup Parameter list ago No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 11 Analog input 1 0 10 V 112 8465 Al1 operating mode 1 10 V reference potential maximum speed hart 5 0 20 mA reference maximum speed 6 4 20 mA reference maximum speed 7 0 10 V n reference 8 0 20 mA n reference 9 4 20 mA n reference 116 10247 6 11 char curve x1 0 100 117 10247 7 char curve y1 100 0 100 96 118 10247 8 char curve 2 0 100 96 119 10247 9 char curve y2 100 0 100 96 12 Analog input AI2 FBG speed control module option 120 8469 AI2 operating mode
37. large load mass moment of inertia such as with pumps and fans The slip compensation is designed for a load mass moment of inertia to motor moment of inertia ratio smaller than 10 If the ratio is larger and the drive vibrates then slip com pensation must be reduced and even be set to 0 if necessary Compact Operating Instructions MOVITRAC B 5 19 5 20 nr Startup Parameter list 5 4 Parameter list All parameters that can also be displayed and edited using the keypad are indicated as follows in the FBG keypad column Selection in the long menu P800 long Lonk Selection in the short or long menu P800 short Shock Ee Display in the pictogram menu in the FBG11B keypad 4TT Selection within FGB motor startup If there are several options the factory setting is underlined No FBG Index Name Range factory setting dec Display MOVITOOLS MotionStudio 0 Display values read only 00 Process values 000 8318 Speed signed rpm z 001 8501 User display for Text DBG11B 002 8319 Frequency signed Hz z 004 8321 Output current IN absolute value 005 8322 Active current N signed 008 8325 DC link voltage V Short 009 8326 Output current A S 01 Status displays 010 8310 Inverter state Text 011 8310 Operating state Text 012 8310 Error status Text 013 8310 Current parameter Current param
38. ng Monitoring Errors 8 26 34 81 82 2 x red flashing Motor protection Errors 31 84 3 x red flashing 1 U flashing status 17 if connected to supply system 24U flashing status 0 if in backup mode A WARNING Incorrect interpretation of display U Safe stop active Severe or fatal injuries The display U Safe stop is not safety related and must not be used as a safety function Compact Operating Instructions MOVITRAC B Operation SS Pr 6 Status displays lt Cause for control The controller inhibit OFF can be caused by the following conditions ler inhibit OFF Binary input terminal 0100 0102 0105 programmed to controller inhibit and acti vated Controller inhibit due to PC manual mode via MOVITOOLS MotionStudio Temporary controller inhibit Is triggered if a change of parameter P100 setpoint source would directly cause an enable signal The temporary controller inhibit is re moved once the enable signal is reset for the first time Controller inhibit set via IPOS control word H484 6 2 2 Status of binary inputs outputs The following parameters are available in the parameter menu as display parameters P039 Binary inputs of basic unit P048 Binary inputs option P059 binary outputs The status is displayed as binary Every binary input or output has two segments verti cally on top of one another of the 7 segment display assigned
39. off with inhibit during copying process Load factory setting or complete Switching off on during copying data set from parameter module process 98 CRC error flash Immediate discon Internal unit error flash memory Send unit in for repair nection defective 100 Vibration warn Display error Vibration sensor warning see Determine cause for vibration ing DUV10A diagnostics unit operation possible until F101 operating instructions Compact Operating Instructions MOVITRAC B Service List of Errors MY VR Error list 00 F113 NY 7 No Designation Response Possible cause Measure 101 Vibration error Rapid stop e Vibration sensor signals error SEW EURODRIVE recom mends that you remedy the cause of the vibrations immedi ately 102 Oil aging warn Display error e Oil aging sensor warns Schedule oil change ing 103 Oil aging error Display error Oil aging sensor signals error SEW EURODRIVE recom mends that you change the gear unit oil immediately 104 Oil aging over Display error Oil aging sensor signals over Letoil cool down temperature temperature e Check if the gear unit cools properly 105 Oil aging Display error e Oil aging sensor is not ready for Check voltage supply of oil ready signal operation aging sensor e Check and if necessary replace the oil aging sensor 106 Brake wear Display error
40. otor Operating mode selection U f characteristic curve U f DC current braking VFC VFC DC current braking VFC flying start function VFC hoist Enter gt Power in KW HP kW x 1 33 Enter Motor voltage V Enter gt Nominal motor frequency Hz Enter Nominal motor speed rpm ap Nominal motor current A aw Enter gt out Enter gt only available with third party motor startup motor noSEW COS phi 4Q mode out Enter gt Number of motors for multi motor drives Compact Operating Instructions MOVITRAC B 27021597782442891 17 Startup 5 D Startup using the FBG11B keypad 5 3 1 Required data The following data is required to ensure startup is successful Motor type SEW or non SEW motor Motor data Rated voltage and rated frequency Additionally for non SEW motors Nominal current nominal power power factor COS and nominal speed Rated line voltage 5 3 2 Activating startup Requirements Drive no enable Stop If a smaller or a larger motor is connected maximum difference one size then you have to choose the value closest to the rated motor power The startup procedure is not complete until you have returned to the
41. rning technical equipment accident prevention regulations etc Do not touch live components or power connections until 10 minutes after disconnecting the frequency inverters from the supply voltage because there may still be some charged capacitors Observe the corresponding labels on the frequency inverter Keep all covers and housings closed during operation The fact that the status LED and other display elements are no longer illuminated does not indicate that the unit has been disconnected from the supply system and no longer carries any voltage Mechanical blocking or safety functions inside the unit may cause a motor standstill Eliminating the cause of the problem or performing a reset may an automatic restart If for safety reasons this is not permitted for the driven machine disconnect the unit from the supply system before correcting the error 2 11 Unit temperature MOVITRAC B frequency inverters are usually operated with braking resistors The braking resistors are usually installed on the control cabinet The braking resistors can reach a surface temperature of significantly more than 70 C Never touch the braking resistors during operation or in the cool down phase once the unit has been switched off Compact Operating Instructions MOVITRAC B Unit Designation Nameplate Type designation 3 Unit Designation Nameplate 3 1 Type designation The following diagram shows a type designation MC 07 B 0
42. s the hardware and software states of the unit Compact Operating Instructions MOVITRAC B Installation 4 Installation The surface temperatures of the heat sinks can exceed 70 Danger of burns Do not touch the heat sink Compact Operating Instructions MOVITRAC B 13 Installation Wiring diagram 4 1 Wiring diagram 3 x AC 400 500 V PE 1xAC 230 V N PE 3 x AC 230 V PE N L3 M PE MOVITRAC B 1 ON X44 9 1 1 F11 F12 F13 K11 ane K11 FSC11B AC 3 oi AC 3 xi L N Qo x1 L1 L2 ep Switchover v l signal gt U signal mA X10 A111 A112 S11 X10 RTI OV 10V 0 4 20mA 10V REF1 U 0 10 V Am 2 A Ci e 0 20 4 20 AM2 3h Reference potential analog sinals 34 GND 4 Higher level i controller X12 Binary Errorreset Diao 1 i input CWistop a DIg1 2
43. t 8351 Binary output 0002 assignment 8916 Binary output assignment No function Malfunction factory setting DOO1 Ready factory setting 0003 Output stage ON Rotating field ON Brake released factory setting DOO2 Not with DOO3 Parameter set Speed reference signal Setpoint actual value comparison signal Current reference message Imax signal IPOS output IPOS fault PI controller actual value reference Ex e current limit active Safe stop Ixt warning Ixt fault WWNHNHNNDND WN CO o 64 Analog outputs AO1 optional 640 anb r 641 642 8568 AO1 analog output No function Ramp generator input Setpoint speed Actual speed Actual frequency Output current Active current Unit utilization Actual speed signed Actual frequency signed X Loca 10248 5 AO1 reference 3000 rpm 100 Hz 150 Nmax Nset reference 8570 AO1 Operating mode No function 0 20 mA 4 20 mA 0 10V NOIN ANDAR 646 647 648 Lonk 649 10246 1 AO1 char curve x1 100 0 100 10246 2 AO1 char curve y1 100 100 10246 3 1 char curve 2 100 0 100 96 10246 4 AO1 char curve y2 100 100 T Control functions on FBG only parameter set 1 70 Operating modes 1 2 70
44. this product Further they are quali fied as follows Training in mechanical engineering e g as a mechanic or mechatronics technician final examinations must have been passed They are familiar with these operating instructions Any electronic work may only be performed by adequately qualified electricians Quali fied electricians in this context are persons who are familiar with the electronic installa tion startup trouble shooting and maintenance for this product Further they are qual ified as follows Training in electrical engineering e g as an electrician or mechatronics technician final examinations must have been passed They are familiar with these operating instructions All work in further areas of transportation storage operation and waste disposal must only be carried out by persons who are trained appropriately Designated use Frequency inverters are components for controlling asynchronous AC motors Fre quency inverters are components intended for installation in electrical systems or ma chines Never connect capacitive loads Operation with capacitive loads results in over voltages and may destroy the unit The following standards apply if the frequency inverters are marketed in the EU EFTA Incase of installation in machines startup of the drive inverters meaning the start of proper use is prohibited until it is determined that the machine meets the require ments stipulated in Direct
45. tion with FBG11B speed control module Manual operation with FBG11B speed control module FBG11B speed control module of the keypad local manual operation LED Z flashes The only relevant parameters in FBG speed control module operating mode are P122 Direction of rotation FBG manual operation RUN key and STOP RESET key Speed control module potentiometer When the FBG speed control module is activated the symbol flashes You limit the smallest speed with P301 Minimum speed and the largest speed with the Nmax Symbol After an error a reset can be performed using the STOP RESET button via the terminal or the interface After a reset the manual setpoint generator operating mode will be active again The drive remains stopped The Stop display flashes to indicate that you have to re enable the drive via the RUN button The parameter P760 Locking RUN STOP keys does not have any effect in manual speed control module operating mode Removing the FBG11B keypad will trigger a stop response Compact Operating Instructions MOVITRAC B Startup using the FBG11B keypad Startup a 5 Level 3 9 Motor selection L SEW DT DV motor Non SEW motor Enter gt 1 IU SEW DRS motor 5 3 Startup using the FBG11B keypad Level 2 WS Haba nu I c SEEuP LES 1D c e Ente Enter gt SEW DRE m
46. to it The upper segment lights up when the binary input or output is set and the lower segment lights up when the binary input or output is not set The two 7 segment displays on the right indicate whether P039 di binary inputs basic unit P048 dl binary inputs option or P059 do 7 binary outputs are output 1761603083 If no FIO21B with binary inputs is available the display will show d1 Compact Operating Instructions MOVITRAC B 33 7 34 e ww Service List of Errors is Error list F 00 F113 7 Service List of Errors 7 1 Error list F 00 F113 No Designation Response Possible cause Measure 00 No error 01 Overcurrent Immediate switch Short circuit at output e Rectify the short circuit e Switching at the output Switching with inhibited output stage only Motor too large Connect a smaller motor Faulty output stage Consult SEW Service if the error cannot be reset 03 Ground fault Immediate switch Ground fault in motor Replace motor off with inhibit ar e Ground fault in inverter e Replace the B e Ground fault in the motor supply Eliminate ground fault lead e Overcurrent see F01 See F01 04 Brake chopper Immediate switch Too much regenerative power