        Operating Instructions iMotion® 2301 Sliding Door Drive
         Contents
1.     T1242_4    Photocell    An activated photocell prevents the closing of the door  Depending on the system  one or two  photocells are installed on the left and right hand side of the passageway of the sliding door     Checks     e Trigger an opening impulse       The door opens     e Shortly after the door commences to close again   cover the photocell with your hand       The door must open again     e Perform the check with the second photocell  if avail    ae  able         Combined sensors with motion detectors and presence detectors  These sensors prevent being hit or squeezed by the moving leaves     Checks       Walk slowly towards the door       The door opens  Stop between the door leaves  and wait max  1 min       The door must not close                                   e Perform this check at the entrance and exit sides of  the door     T1242_3    10 Operating instructions iMotion 2301 2401 T 1321 e    Mechanical Emergency Opening Facility     Checks       Simulate a power failure  pull the power plug or switch off the main system switch  or select  operating mode P       The door leaves must open fully     Electrical Emergency Opening Facility    Checks     e Simulate a power failure  pull the power plug or switch off the main system switch          The door behaves according to the programmed operating function of the battery unit  see  section 3 6      e Restore mains supply     Manual Disengagement  Checks     e Switch off mains supply       Check that the d
2.  6 2  EN 61000 6 3  UL 325    9 2 Warranty Claims    Malicious or wilful damage to and contamination of system components as well as modifications  to the drive and control system by third parties renders all warranty claims null and void     9 3 Optional Extras    The following are some of the optional extras which are available  electro magnetic lock  key switch   security features and a range of activators  Please ask your TORMAX dealer for more information     9 4 Disposal    This system must be properly dismantled at the end of its working life and its disposal carried  out in accordance with national regulations  We recommend that you contact a specialist dis     posal company     When disassembling the battery module  there is a potential hazard from acid     The tension of the rubber cord must be relaxed carefully     Contents subject to technical changes     14 Operating instructions iMotion 2301 2401 T 1321 e     X   x x   gt i    T    R M AX Your First Choice for Automatic Doors    AUTOMATIC    TORMAX Sliding Doors  TORMAX Swing Doors  TORMAX Folding Doors  TORMAX Revolving Doors    TORMAX Slide Swing Doors    Manufacturer  Advice  sales  installation  Repairs and service     TORMAX   CH 8180 B  lach Z  rich    Phone  41  0 44 863 51 11  Fax  41  0 44 861 14 74  Homepage  www tormax com  E Mail info tormax com    TORMAX is a Division and a registered trademark of Landert Motoren AG    
3.  Lock is jammed or defective  In operating mode OFF and   OFF  closed door  Press the door  leaves for a few seconds  against the closed position    Lock is jammed or defective  Select operating mode AUTO   MATIC 1  Press the door  leaves briefly against the  closed position     Door does not open af   ter changing from OFF  to AUTOMATIC   Lock produces periodic  switching noise     Door does not open in Lock is jammed or defective  Turn on key switch and subse   OFF through the key quently press the door leaves  switch  briefly against the closed posi   Lock produces switch  tion    ing noise     Door remains closed  Safety facility in opening direction is Remove the objects within the  permanently active range of the sensor     gt  1 min   or defective     Safety facility in closing direction is per    Remove the objects within the  manently active range of the sensor     gt  1 min   or defective     Safety facility in opening direction is Remove the objects within the  permanently active range of the sensor     gt  1 min   or defective     Door does not open or E Safety facility stop is permanently active   Remove the objects within the  close   gt  1 min   or defective  range of the sensor     Door remains open  E41 Activator inside is active  gt  1 min  Get sensor adjusted by a pro   E42   Activator outside is active  gt  1 min  fessional   E43 J Key switch is active  gt  1 min  Reset key switch     Door stops  Deviation in the travelling path  Remove firm obstacle in th
4.  safety fa   cilities  Thus  functional disturbances or safety endangering changes to the system can be  detected early     If faults are determined during the periodic checks  arrangements for getting these repaired by  a TORMAX dealer  address see back page of these instructions  must be made immediately     When performing these checks  consider always the possibility of a malfunction of the system   If sufficient free space is not available  do not use any parts of your body for operational tests   use a Suitable object as a substitute  e g  polystyrene or cardboard      Operating instructions iMotion 2301 2401 T 1321 e 9    The checks to be carried out by the system operator require only a very low expenditure of time  but are essential for a safe and sound operation of the system     The checks by the system operator include     Checking the Sensors    Set operating mode to AUTOMATIC 1     Automatic Motion Detector   The motion detector triggers the automatic opening of the door  The sensor must be effective  over the total door width  The general flow of traffic and direction of traffic for the given situation  are to be considered during these checks     Checks       Walk through the door in a normal speed       The door starts to open approx  1 5    2 m before  it is reached  Immediately before reaching the door   it must already be open to at least 80   of the open   ing width                          e Perform this check at the entrance and exit sides of  the door 
5.  work is not carried out by the designated person  the  manufacturer will reject any product liability and warranty     2 2 Permissible Use    The door automation system TORMAX iMotion 2301 and iMotion 2401 Sliding Door Drive is  built according to the current state of technology as well as the recognized safety relevant  rules     The sliding door system is intended exclusively for the deployment in dry rooms and or  for  outer doors  at the inside of a building in the pedestrian passageway  The operator can only be  used at the exterior of a building if additional protective measures are taken and under observ   ance of the acceptable environmental conditions     Any other use  or any use exceeding this aim  is deemed as not used in accordance with its  intended purpose  The manufacturer will not be liable for damages resulting from such applica   tions  The risk will be borne entirely by the operator of the door system  i e  the system operator     Arbitrary changes to the system will exempt the manufacturer from any liability for damage re   sulting from this     2 3 Taking the System Out of Service in Case of Fault    The door automation system must be taken out of service as soon as faults or deficiencies  occur that may impair the safety of people     e Switch off the mains supply to the system    e Select operating mode    P    if system operation will be continued by means of the internal  battery backup system     e Open the door manually if it is installed in an es
6. F and optionally also in other operating modes  e g  EXIT      Operating instructions iMotion 2301 2401 T 1321 e 5    The locking facility is monitored  A possible fault in the lock operation can thus be displayed  immediately on the user interface  Details see chapter 8    Trouble Shooting        On power failure the locking facility can be activated directly through the optional manual con   trol     3 6 Operation on Power Failure   The following functions are possible according to specifications    e Immediate emergency opening activated through a mechanical energy storage   e Immediate emergency closing through a mechanical energy storage    e Immediate unlocking  if programmed by the fitter      e Continued operation of the system through a battery unit during a determined time with door  opening before the battery shuts down  In operating mode OFF the door remains locked     e Unlocking and opening of the from the outside through the key switch and through the battery  unit     4 Commissioning    Before switching on mains supply   e Unlock the optional mechanical locking mechanisms e g  floor lock       Make sure that the operating range of the door leaves is free of items such as umbrella stands  or trolleys       Check if the floor guide  particularly a continuous guide  is clean and free from items  e g   pebbles or snow      e Switch on mains voltage and select the operating mode  e g  AUTOMATIC 1         The first motion after switching on mains supply for the firs
7. KKK KK    TORMAX    AUTOMATIC T 1321 e 10 08                             Operating Instructions    for Automatic Sliding Doors    iMotion   2301 Sliding Door Drive  iMotion   2401 Sliding Door Drive    Content    2 1  2 2  2 3    3 1  3 2  3 3  3 4  3 5  3 6    5 1  5 2  5 3    7 1  7 2  7 3    9 1  9 2  9 3  9 4    Regarding these Instructions    Safety   Preconditions for the Operation of the System  Permissible Use   Taking the System Out of Service in Case of Fault    Functions of the System  Operating Modes   Automatic Door Operation with Sensors  Traffic Control   Automatic System Monitoring  Electromechanical Lock   Operation on Power Failure    Commissioning    Operation   Operation Through TORMAX User Interface  Operation through 3 Position Switch  Operation on Power Failure    Operating Modes    Maintenance   Cleaning and Maintenance   Checks by the System Operator  Annual Maintenance and Inspection    Trouble Shooting  Additional Notes    Technical Data  Warranty Claims  Optional Extras  Disposal    First edition  10 08    We print on environment friendly paper bleached without chlorine     The companies Landert Motoren AG and Landert GmbH are certified according to ISO 9001     2 Operating instructions iMotion 2301 2401 T 1321 e    CONN OD    9 9         Q        QI A KR S   oO      o o O   O    14  14  14  14  14      eL  gt  gt     wA A    1 Regarding these Instructions    Addressee Status    The person responsible for operation and maintenance of the system is 
8. System    The door system was planned  installed and checked by qualified professionals with regard to  performance and safety before it was handed over to the system operator    The system operator was instructed by the installation company concerning operation and  maintenance of the system as well as the dangers associated with system operation     Prior to commissioning of the door  these operating instructions     in particular the safety notes      are to be perused and they must be observed     In addition to the operating instructions  the generally applicable legal and the safety relevant  regulations and rules of industrial medicine for accident prevention and for environmental pro   tection in the respective country  in which the system is operated  are also applicable     The responsibility for the instruction of the service personnel  the permissible use and the ad   herence to the maintenance regulations lies with the system operator  Get acquainted with the  operation of the system by studying the operating instructions     Use the system only in a technically sound condition  Safety devices may not be removed or  made ineffective  Make sure that possible fault situations are eliminated immediately by qualified  professionals     For a most secure and reliable operation of the system  the door automation system must be  serviced at least annually and submitted to a safety relevant examination by a qualified profes   sional trained for this kind of work  If this
9. cape route   For information relating to fault indication and trouble shooting see chapter 8     4 Operating instructions iMotion 2301 2401 T 1321 e    3 Functions of the System    3 1 Operating Modes    The door automation system can be operated through the TORMAX user interface   with 6  operating modes and status display or optionally through a simple rocker switch    with 3 oper   ating modes     3 2 Automatic Door Operation with Sensors    In automatic operation  operating mode AUTOMATIC 1   the door opens automatically to both  sides through sensors when a person approaches  In exceptional cases  it opens through de   liberately to be activated switching devices such as push buttons or card readers for controlled  access     A key switch usually permits access to the door from the outside also in operating mode EXIT  or OFF  The door unlocks  opens and closes again as soon as no further sensors are activated  any more after expiry of a separately adjusted hold open time     The sensors for the door opening and the maintained opening of the door are arranged and  adjusted in such a way that the door opens promptly and remains open as long as a person is  within the operating range of the door leaf  The door can close nevertheless but only after an  attendance time of approx   gt  1 minute     The reduced closing speed  which is adjusted by the fitter and adapted to the door weight  in  combination with a force of  lt  150 N  prevents an excessive impact on a person by th
10. e    Door remains open     Door does not open or  close    E11  E11  E31  E32  E33   34    Fixed obstacle in the travelling range  travelling range of the door   Perform a software reset     Door stops  E61 Power supply is overloaded or voltage Get the power supply and con   E62   too low  nections checked by a profes   sional   Perform a software reset     Drive control system is overheated  Wait for the automatic reset  E65 after cooling down   Avoid exposure to the sun   E8    ae    are   see section 2 3        Operating instructions iMotion 2301 2401 T 1321e 13    A    9 Additional Notes    9 1 Technical Data    Door operator types    Drive system    Control system  Mains connection  Power consumption  iMotion 2301  iMotion 2401  Sensor power supply  iMotion 2301  iMotion 2401    Protective class of drive  Ambient temperature  Outputs   iMotion 2301   iMotion 2401  Approvals  Standards    iMotion 2301 Sliding Door Drive  iMotion 2401 Sliding Door Drive    Electromechanical sliding door operator with direct drive through  AC permanent magnet synchronous motor with external rotor    Control Unit MCU32  1 x 230 1 x 115VAC  50  60 Hz  10A    max  190 W  max  310 W    24 V DC   0 5   1 5V  0 75 A    24 V DC   0 5   1 5V  1 5 A  in battery operation min  16 5V    IP 22     20   C to  50   C    24 VDC short circuit proof  within power supply 0 75 A in total   24 VDC short circuit proof  within power supply 1 5A in total   CE incl  RoHS  TUV  ETL   DIN 18650  EN 60335 1  EN 61000
11. e moving  leaf  Additionally  the obstacle is detected by the control system and an automatic reversal of  the door is initiated     Sensors for safeguarding the moving leaves can also be present in opening direction depending  upon the surrounding conditions  e g  column near the operating range  and design of the  system  safety clearances   When a person moves into the danger area  the door leaf stops or  slows down to a very low speed depending upon the adjustments performed by the fitter     3 3 Traffic Control    The passageway can optionally be blocked in one direction  operating mode EXIT  or be com   pletely closed  operating mode OFF   In these operating modes  an optional electromechanical  lock can be used for protection from unauthorized access     For protection from environmental influences  wind   cold weather   heat   the door can be oper   ated with a smaller opening width  operating mode AUTO MATIC 2      3 4 Automatic System Monitoring    The control system monitors the safety sensors by cyclic active testing  Further  the control  system performs continuously internal system tests  On failure of a safety relevant component   the system changes automatically into a safe state  Thereby  the fault number is displayed on  the user interface    Please refer to chapter 8    Trouble Shooting    for further information     3 5 Electromechanical Lock    The system can be locked in the closed position through an optional electromechanical lock in  operating mode OF
12. erating mode can be used for the cleaning of the  door leaves and floor guide or for a temporary shut down of the system     A system reset takes place after quitting this operating mode     7 Maintenance    The system was inspected and accepted by a qualified professional before initial operation  The  manufacturer recommends making arrangements for a service contract so that the value of the  system is maintained for as long as possible and the system operates reliably and safely in the  long term     The following maintenance work is to be carried out   e Regular cleaning of external system parts and floor guides   e Checks by the system operator at least every 3 months       Annual maintenance and inspection of the system by qualified professionals     Genuine spare parts are to be used exclusively     7 1 Cleaning and Maintenance    e In operating mode    P     clean the door leaves  casing parts and user interface with a damp  cloth using a commercial cleaning agent     e In operating mode    P     remove dirt from the floor guide and clean it with a damp cloth     e Check the door system and operating devices outside visually for recognisable damages and  deficiencies     e Check whether unusual noises can be heard during the motional sequence     7 2 Checks by the System Operator  Extent of the Checks    The system operator of an automatic door system must check in periodic time intervals   however at least every 3 months  the performance of the automatic door and the
13. list  Address see back page or service label at the system     Fault Table    Door stops during Electronic obstacle recognition on Remove obstacle  Clean floor   opening  opening by a person  wind pressure  guide in operating mode P  ventilation or dirt in the floor guide    Door reverses during Electronic obstacle recognition on clos    Remove obstacle  Clean floor   closing  ing by a person  wind pressure  ventila    guide in operating mode P  tion or dirt in the floor guide    Door stops repeatedly Electronic obstacle recognition on Remove obstacle  Clean floor    during opening  opening in the same position by station    guide in operating mode P  ary obstacle    Door stops repeatedly Electronic obstacle recognition on clos    Remove obstacle  Clean floor   during closing  ing in the same position by stationary guide in operating mode P  obstacle     een for search H61 Search run of the door after reset or af    Allow the search run to be  H62   ter power recovery  completed    Door functions with re  Battery operation Wait for power recovery   duced speed  Switch on mains supply        12 Operating instructions iMotion 2301 2401 T 1321 e    Behaviour of the Cause Remedial Action   Reset   System   Door remains closed  Operating mode like for instance    OFF      E g   select operating mode     EXIT     or    P    AUTOMATIC 1    Door remains open  Operating mode like for instance E g   select operating mode     OPEN     or    P    AUTOMATIC 1     Door does not lock in E11
14. onds     The software is restarted  Subsequently  the control system performs a calibration run  checks  the travelling path and searches again for the end positions  The display shows H61 and H62     5 2 Operation through 3 Position Switch    Selection of the Operating Mode    OFF    AUTOMATIC 1    OPEN O    The operating mode can be set directly        T1165_10     System reset by separating the system from mains supply for at least 5 seconds      Operating instructions iMotion 2301 2401 T 1321 e T    5 3 Operation on Power Failure    Manual Lock      1  Turn manual control in clockwise direction    2  Push the door closed by hand until the lock bolt latches   When the power returns  operating mode OFF is selected automatically due to the engaged    door lock     Manual Disengagement  1  Turn manual control in the counter clockwise direction    2  Push the door open by hand     Opening Through Key Switch with Battery Unit     e Actuate the key switch for at least 3 sec  and turn it back again         The battery is switched on through the wake up function       The door is unlocked and opened         The battery switches off again     6 Operating Modes    Operating Mode OFF   The activators inside and outside are not observed  The door is pushed close by the motor and  is locked by the electromechanical door lock    Access is only possible through the key  switch       After the operating mode OFF has been selected  the door can still be used for 5 seconds  The  i door lock
15. oor can be locked and unlocked       Open the door and lock the lock with the rotary knob       The door must be able to be locked by pushing it closed     e Restore mains supply     7 3 Annual Maintenance and Inspection    Service Interval    Service interval is defined under consideration of the frequency of use  However  mainte   nance and inspection must take place at least once annually by a qualified professional  trained for that purpose     Requirements for Maintenance Staff    Qualified professionals are persons who have adequate knowledge in the discipline of power  operated doors based on their vocational training and experience and who are acquainted with  the applicable accident prevention regulations  guidelines and generally recognized rules of that  technology to such an extent that they can appraise the safe working condition of power oper   ated doors  These persons include for example professionals of the manufacturing or supplying  company and experienced professionals of the system operator     Qualified professionals have to submit their expertise objectively from the point of view of ac   cident prevention and must not be influenced by other requirements  e g  financial demands     Maintenance work on electrical parts must be performed by an electrical fitter     Extent of Maintenance Work    The extent of maintenance work is set out by the manufacturer  The inspection may only be  carried out by a person trained for that purpose as specified by the man
16. referred to as    system  operator     The system operator is responsible for the operation and maintenance of the sys   tem     Area of Application  This document is applicable for sliding doors with TORMAX automatic door operator of type     iMotion   2301 Sliding Door Drive  iMotion   2401 Sliding Door Drive    Explanation of Symbols    In these instructions we have marked all positions which concern your safety with this symbol     This symbol warns of electrical voltage   Text passages in grey background must be absolutely observed for sound operation of the  system  Disregard may cause material damage     Operating functions that are marked by the accompanying symbol correspond to the basic set   tings  however  the fitter can reprogram them     This symbol marks optional components  which are not installed in all systems     Symbols for Operating Modes    Operating mode OFF O Operating mode EXIT   Operating mode AUTOMATIC 1 C  Operating mode OPEN   Operating mode AUTOMATIC 2 P Operating mode P Manual Operation  Languages    These instructions are available in different languages  Please ask your TORMAX dealer     Applicable Documents    In the system test book  checks are listed that must be performed on periodic examination of  the system  see also section 7 3   The location of the test book is at the respective door sys   tem     System test book  T 879 e    Operating instructions iMotion 2301 2401 T 1321 e 3    2 Safety    2 1 Preconditions for the Operation of the 
17. s after this time has expired and as soon as it is closed  This transition is indicated on  the user interface by a flashing display of the operating mode OFF     Operating Mode AUTOMATIC 1    The operating mode AUTOMATIC 1 is commonly used for operation during the day  The door  opens automatically to both sides through the inside and outside sensors and usually to the full  Opening width     Operating Mode AUTOMATIC 2    The operating mode AUTOMATIC 2 is commonly used for operation during the day  The door  opens automatically to both sides through the inside and outside sensors and usually to a re   duced opening width  If necessary  the hold open time can be adjusted by the fitter  different  from AUTOMATIC 1                  Operating Mode EXIT    The operating mode EXIT is commonly used for operation before closing time  The door opens  automatically only through the sensor inside  During the door opening  the sensor outside is  observed likewise for safety reasons  The opening width is determined by the preceding selec   tion of the operating mode AUTOMATIC 1 or AUTOMATIC 2  Aditionally the door can be locked  automatically by the door lock       1       8 Operating instructions iMotion 2301 2401 T 1321 e    Operating Mode OPEN    The door opens and stops in the open position  The opening width is determined by the preced   ing selection of the operating mode AUTOMATIC 1 or AUTOMATIC 2     Operating Mode P Manual Operation    The door leaves are freely movable  This op
18. t time takes place slowly with in   dication of H61 and H62  Thereby  the control system checks the travelling path of the door leaf  and determines the end position         The door is now ready for use     5 Operation   The following operating devices are available for the operation of the system depending upon  outfit      TORMAX user interface        Lock for user interface        TORMAX 3 position switch        Key switch    or card readers outside         Manual control for door lock       6 Operating instructions iMotion 2301 2401 T 1321 e    Systems without user interface or 3 position switch are either provided with a fixed operating mode   e g  AUTOMATIC 1  or are centrally controlled by a time clock  e g  OFF   AUTOMATIC 1      Push buttons  elbow switches etc  can be installed in place of  or in addition to the sensors     5 1 Operation Through TORMAX User Interface  Selection of the Operating Modes       Symbols for  operating mode  Selection  key 1     el upwards  AUTOMATIC 1    eql  C   ae Electr  door lock  ER ku Additional operating  ol  e      P  EXIT    section  OPEN www tormax com key 2  downwards    T1321_1e    e Unlock optional lock for user interface     e Press selection key 1 or 2 briefly  The corresponding operating mode is displayed     Indication of Faults  E g  H31 or E11    For the significance of the indication see chapter 8     e Reset the indication by briefly pressing selection key 2    System Reset  e Press selection key 2 for at least 5 sec
19. ufacturer     Test Book    The findings of the inspection are finally entered into the test book  The test book is to be kept  by the system operator at a save place     Operating instructions iMotion 2301 2401 T 1321e 11    8 Trouble Shooting    Malfunctions become evident by unusual behaviour of the door and or as a result of an error  message on the user interface  Error messages appear on the user interface as a flashing    E     or    H    followed by two figures     Indication H   information     the operation of the system can be continued   Indication E   fault  gt  the system has stopped  It must be repaired     Some malfunctions can be quickly rectified by restarting the door drive with a software reset  and or briefly switching off the power supply to the door drive     Display and reset of the error with TORMAX user interface    Step through the faults on the display  if several faults are displayed     1  Reset the error message       g   ai    2  Push 5 s for software reset    T1242_2    Fault reset with 3 position switch    Software reset in the event of a breakdown  change operating mode        T1238_4    Fault reset by cutting off the power supply  Installations without battery unit  cut off power supply for approximately 10 s    If the malfunction cannot be rectified or if it re occurs after a short time  you should arrange for  it to be rectified by a fitter from your TORMAX dealer  In this case  note the error number and  pass the information to the specia
    