Home
Aperio Online Mechanical Installation Manual - Ruko e-shop
Contents
1. hardware used and the level of integration Please contact your OEM for details Abbreviation Definition EAC Electronic Access Control The system controlling the access rules which is then conveyed to user cards through the Offline Updater RFID Radio Frequency Identification The credential technology used References 1 ST 001321 Aperio Programming Application Manual 2 Aperio Offline System Description Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 3 Aperio Offline Figure 1 Aperio technology overview 2 System Overview Programming application m IEEE802 15 4 2 4GHz Aperio OFFLINE The Aperio system The Aperio system is used in the following way The user holds an RFID card in front of an offline lock Access decision is taken locally by lock Result of decision depends on access rights stored on the card and also on lock configuration received from the EAC through offline updaters with setup or user cards Aperio online locks communicate to the EAC through communication hubs for more information refer to the Programming Application manual ref 1 EAC system Electronic Access Control The Aperio Programming Application The Programming Application is used for the configuration of a door installation It is normally installed on a laptop and is used with an Aperio USB radio dongle connected to one of the USB ports The USB radio
2. the Aperio Programming Application File Installation Help New Installation Ctrl N OFFLINE Open Installation Ctrl O Import Installations Ctrl I Connect Di Preferences Exit Ctrl F4 ou 3 Entera name for the installation a password matching the requirements and finally click the button in the Key file field to add the Encryption key Installation An installation represents a complete Aperio system The password is used to securely encrypt all settings and configurations for the installation A minimum of 8 characters with uppercase lowercase and numbers is required It also can t be the same as the installation name The key file contains unique keys that are used to secure the radio communication and prevent unauthorized reconfiguration ofthe system Do notuse the same key file for different installations Installation Name new installation Password m Repeat Password eeeeeeeee Key File iolMjukvarallicence xm m e Proper handling of encryption keys is essential to lock sensor security Itis absolutely necessary to use the customer encryption key by setting all communication hubs and locks sensors in Customer mode to ensure a secure and encrypted communica tion with the lock sensor 4 Select the key file and click Select The xml file key file containing the encryption keys 5 Click Create Aperio Offline Quick Installatio
3. the Physical location data Show cardiengage sensor Time remaining until timeout 12 seconds u Step 5 Applying a stored configuration to a lock Ifyou have more than one lock that will use the same configuration you can apply the previously saved configuration on any lock in your installation 1 Connectto another lock that you want to apply a saved configuration on In the Installation view right click the new lock and select Apply configuration and choose an earlier stored configuration File Installation Help ONLINE OFFLINE N amp amp e a lt Quick sean Refresh Connect Disconneet Lock Lock Id Lock Group Assigned Address General Information SE TUS M Floor 1 Offline L ati Apply Configuration loor 1 Offline Leck configuration 00 17 7A 01 02 01 99 66 BE UhfAddress Ow1001 Retrieve System Information Physical Location Office A Retrieve Event Log Radio Channels 11 16 25 Ret RADICE Tai Active Channel 16 2 430 GHz Security Mode Customer Mode Change Lock Identification Details Time Zone UTC Europe Dublin Change Radio Channels Site Code 1010 Switch to Manufacturer Mode Toggle Mode Disabled Upgrade Firmware Device Details Factory Reset Default Scheduled Open Start Time End Time Door information Lock Id Lock Group MIFARE Classic Configuration Total number of sectors 4 Number of alarm sectors 1 Number of Scheduled Open sectors 1 S
4. 322 G Date 4 July 2014 Aperio Offline Step 6 Testing after configuration Follow these steps to test that the configuration of each lock has been performed correctly and that the hardware is working 1 Hold a credential that is invalid in the EAC system in front of the lock Result Access is denied and the lock LED flashes red once Access adus One red flash denied S 1 second 2 Hold a credential that is valid in the EAC system in front of the lock Result Access is granted and the lock LED flashes green once Access Ad One green flash granted 1 second See section 4 LED Indications on page 22 for details on the different LED indications Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 21 Aperio Offline 22 4 LED Indications Offline Lock LED Indication The Aperio Offline lock has a single LED that supports an optical scheme with red green and yellow The indication scheme differs depending on the credential type presented at the lock Access a One green flash granted n 1 sec Access adult One red flash denied AN 1 sec Open lock Au One green flash permanently M 1 sec In toggle Close N One yellow flash mode lock e 125 sec Access s Ad S One red flash denied M IL 1 sec Scheduled open enabled card first swipe Scheduled open zt One yellow flash unlocked s 125 sec Second swipe
5. Aperio Offline Quick Installation Aperio 9 Offline Table of Contents Aperio support in the EAC system Abbreviations and Definitions nanan annnanannsssnnsnsnssssssssssss MUN OS che ss TEE w an waters dan Qa Wale k n asqa FE eu DY A NN ree e r zl waw The ADERIOSVSEGITI n kiyan T E W diyne ea N bebin du dern ya i yeee n kein aenan The Aperio Programming Application Regulatory and security information 3 Quick Installation of Aperio offline locks Information of encryption key Checklist for quick installation of offline locks Preparation before quick installation tete erk EEE terre ua ade Step 1 Creating a new installation essent ttt ses kasik z otte b se tesaks y Step 2 Connecting to an offline lock Step 3 Configuring locks Wizard zt rte dere t te RE WER REID COMPIS tr GEL OM cis E General settings Scheduled Open amp Schedule Data a nama anaq etin h deed kS rain kk W n aA a iy Mode Settlig octets a umasa unamasa inina a A EE REA Device update page Saving Configuration Step 4 Adding Lock Identification Details u u u a a Step 5 Applying a stored configuration to a lock esent 19 Step 6 Testing after config UFatIOIu ya ananas awana ua Rete REK A N tn 21 LD 6 ii DD
6. Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline 7 Click Close to exit the wizard Device update result The result of the device update will be presented below Successful Time zone daylight saving time data Time and date UTC MIFARE Key Default scheduled open security mode 4 Back Close Cancel Step 4 Adding Lock Identification Details 1 Select the lock right click and select Change lock identification details File Installation Help ONLINE OFFLINE de R e Quick sean Sean Refresh Connect Disconnect Lock Lock Id Lock Group Apply Configuration Configure Retrieve System Information Retrieve Event Log Retrieve Audit Trail _ Change Lock Identification Details Change Radio Channels Switch to Manufacturer Mode Upgrade Firmware Factory Reset Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio 9 Offline 18 2 Enter the lock identification details either Manually or through Imported data by selecting one of the radio buttons a Manually Enter Physical Location max 21 alpha numeric characters Lock Id max 5 numeric characters 2 bytes 0 65535 Lock Group max 5 numeric characters 2 bytes 0 65535 amp max value decided by RFID configurations Change lock identification details manually or through imported data Enable choosing l
7. ata Protection Level Security level for the communication between lock and card Choose one of the two options Data Authenticity by MAC Full Encryption depending on how the cards used in the system are configured Number of alarm slots Numeric value representing number of alarm slots on access cards used in the system Number of scheduled open slots Numeric value representing number of scheduled open slots on access cards used in the system Number of lock groups Numeric value representing maximum number of allowed lock groups on access cards used in the system Key Type Choose one of the three options 2K3DES 3K3DES AES 128 depending on the cryptographic algorithm used to read write data from to the card Type the key value in hexadecimal 2K3DES and AES 128 are 16 byte keys 3K3DES is a 24 byte key Key MIFARE DESFire key that applies for the user cards in your installation in HEX format Example 0 0112233445566778899aabbccddeeff Key Number Each application can use up to 14 keys Key 0 is always the Application s Master Key Type here which key number that is used for the Programming application on the MIFARE DESFire cards Key numbers range from 0 to 13 System limitation It is up to the system owner to assure that there is space enough on the access cards used for the actual system configuration Possible configurations are dependent on the size of the MIFARE DESFire EV1 cards used in the system and if they are used fo
8. chedule xml data Select an appropriate file containing schedule data Currently Lock 019966 contains no valid schedule data Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline 14 Change Scheduled open settings A Start Time hr min O End Time hr 17 gt min O gt O J lt J Start time Start time for when the lock can be activated for scheduled open For when access cards with scheduled open functionality can set the lock to be open End time End time for when the lock responds to scheduled open attempts It is also the time when the lock goes back to locked state after being scheduled open unlocked The schedule open function has several options please refer to the Aperio Offline System Description manual for more details Security Mode Settings Security Mode Setting Set the security mode that will be used for radio communication Should be switched to Customer mode to ensure secure radio communication E Mode Setting Security mode will not be changed Change 1 Click Change in the Security Mode Setting area if you want to change the security mode or click Next 2 Tochange to customer mode click the check box and click OK Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Off
9. connecting to a lock Problem indication The lock is not found when All radio channels are busy 1 Click Connect again trying to connect no The programming application 2 Change the radio channels See the Programming connection between the and the lock have different radio Application manual programming application channels laptop and the lock The lock is not working The lock is not powered The lock is out of range of the USB dongle Unstable communication A probable cause is bad radio Try moving the USB radio closer to the lock Either by between lock and Radio conditions or limited radio range moving the laptop or by using an A A USB extension dongle even though the cable to distance the USB radio from the PC MAC address is displayed after connecting to lock The device update fails Radio not activated in lock Perform device update again and show the radio activation card to the lock During normal operation Problem indication The lock LED is flashing red The battery of the lock sensor has Change the battery of the lock See the run out Programming Application manual Hardware failure Lock jammed Service the lock Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 25 ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience Contact www assaabloy com aperio Wi
10. ct the number of lock groups that can be used see sec e tion Step 4 Adding Lock Identification Details on page 17 Plan your sector configuration with the following limitations in mind IEEE MIFARE Classic 1K MIFARE Classic 4K Max lock units 65536 65536 Max lock groups 1344 5088 Max alarms 84 420 Having max lock groups means no alarms and vice versa since they share the same storage space on the credential It is up to the system owner to ensure that the appropriate number of sectors needed to represent all doors are reserved on all user credentials in the system It is recommended to add extra sectors not reserved for alarms schedules in order to obtain space for lock group addressing Each free sector allows 96 lock groups MIFARE Classic 1K card Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 11 Aperio 9 Offline 12 DESFire Configurations lt MIFARE DESFire Configuration Application ID 1 File Data Protection Level Full encryption Number of alarm slots 0 Number of scheduled open slots 0 Number of lock groups 32 Read Key Configuration Key Type AES 128 gt 00112233445566778899aabbccda Key deeff Key Number 1 Application ID Identification number for the Programming application on the MIFARE DESFire cards used in the system A MIFARE DESFire card can have up to 32 applications Application ID s range from 0to 16777215 File D
11. d Card read OK Card read FAILED Figure 5 Offline lock LED indication Void list card Card detected Card read OK Card read write FAILED Figure 6 Offline lock LED indication Audit Trail card Lock Maintenance LED Indication One yellow flash 1 sec Yellow flashes 25 second repeated for 1 min Green flashes 25 second every sec for 1 min One yellow flash 0 125 sec One green flash 1 second One red flash 1 second One yellow flash 0 125 sec One green flash 1 second One red flash 1 second Some special LED indication schemes are used during lock maintenance actions Enter configuration mode Na a a 9 0070 e Five yellow flashes 125 second each Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 23 Aperio 9 Offline 24 Lock self test LED indication After replacing the battery a Power on Self Test POST is performed The result is indicated using a series of red and green LED flashes as is described by the figure below A X SA ahs One red one green flash 1 second POST Successful AM m 9 andyellow flashes for 20 seconds UHF activated SELL Vous ul ts One red flash 16 red or green flashes 5 second Failure during POST m ert IN i and yellow flashes for 20 seconds UHF activated Battery not fully charg
12. dongle enables the programming application to connect to an offline lock Regulatory and security information Refer to the Aperio Programming Application manual ref 1 for regulatory and security information Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline 3 Quick Installation of Aperio offline locks After the hardware installation of the locks the Aperio Programming application is used to configure the locks for use in an access control system Optionally a lock setup card might be used as a first step to make a fast but limited configuration before the configuration with the Aperio Programming application is done This chapter will guide installation personnel to configure Aperio Offline locks using the Programming Application with default settings for an offline access control system RFID user card setting of RFID Key and configuration scheduled open and secure communication Perform all instruction steps in this chapter to complete an installation All advanced settings are described in the Aperio Programming Application manual ref 1 Information of encryption key To obtain secure communication between the Programming Application and locks an Encryption key is used This Encryption Key Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 should be handled with the same care as the Master Key in a traditional Master Key Syst
13. ed 10 red flashes 125ms followed Energy counter not reset s _ _ by yellow flashes for 20 seconds UHF activated No power on self test done Figure 7 Lock POST LED indication amp If the battery is not accepted as new after a power on reset no POST is performed instead the 10 quick red flashes used to indicate Error in lock is shown The first flash is always red If the POST fail the color of the 16 trailing flashes indicate the status of each individual test as described by the following table Blink Meaning if red Code in event log 1 POST initiation flash 2 Main board firmware corrupt 0x0001 3 Reserved for future use 0x0002 4 Production data corrupt 0x0004 5 Production data corrupt 0x0008 6 Configuration data corrupt 0x0010 7 Load circuit corrupt 0x0020 8 Configuration data corrupt 0x0040 9 Secure area key error 0x0080 10 Secure area motor error 0x0100 11 Secure area Communication error 0x0200 12 Secure area memory error 0x0400 13 Secure area motor sensor error 0x0800 14 Radio modem communication error 0x1000 15 Radio modem memory corrupt 0x2000 16 Radio modem EEPROM corrupt 0x4000 17 Radio modem RF error 0x8000 Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline 5 Troubleshooting The tables below show possible problems when using the Aperio technology and how to solve them When
14. em A person with access to the Encryption key can gain unauthorized access to any Aperio door in the system Once loaded into the Programming Application it will be stored encrypted in a local database and any copy should be erased from the hard drive or e mail It is however recommended that a copy of the encryption key is stored in safe The encryption key file is delivered from your local ASSA ABLOY company and should be requested on a customer site basis Proper handling of encryption keys is essential to lock sensor security It is absolutely necessary to use the cus tomer encryption key by setting all locks in Customer mode to ensure a secure and encrypted communication with the lock Aperio 9 Offline Checklist for quick installation of offline locks To communicate with and configure locks you need the following Aperio Programming application USB Radio dongle Radio activation card RFID MIFARE Classic DESFire user card for testing Encryption key from your local ASSA ABLOY company Figure 2 Equipment needed Programming application Lock Tritech TriBee USB dongle N Radio activati d hak adio activation car card A complete quick installation includes the For some configurations a number of additional following steps advanced settings can be necessary such as advanced lock settings and configuration of the Preparation Installation of software and radio communication powering
15. line The default mode is Manufacturer mode but you should always change it to Customer mode If you change to Manufacturer mode the lock will no longer be using secure radio communication Device update page Saving Configuration The Device Update dialog box shows a summary of the configuration tasks that will be downloaded to the lock The configuration may be saved to facilitate configuration of additional devices with the same information Device Update The configuration is ready to be transmitted You might need to show a card to the lock or engage the sensor Click Next to transmit the configuration The following updates will be transmitted to the Aperio Lock sensor Time zone UTC 01 00 Central European Time Europe Berlin Daylight saving time data Time and date UTC MIFARE Key Key B 222222222222 Default scheduled open Start time 07 00 end time 17 00 Security mode Customer Mode Save Configuration 1 2 Ezan xg Cms Click Save configuration Enter a unique and suitable name for this configuration in the Configuration name field Choose this name carefully to make it clear what settings are changed in the lock sensor or communication hub You could for instance name it according to the different configuration tasks or if applicable use a name that reflects the specific door type Save configuration to local storage Selectthe configurations i
16. lowing settings RHD user card setting of RFID Key and configuration RFID configuration dialog Site code and time zone General settings dialog Scheduled open Configure Schedule open settings amp schedules dialog Secure communication Security Mode Settings dialog Everything is skipped without changes in this workflow by clicking Next except Time zone Daylight saving time data and Time and date UTC For other settings other than mentioned here refer to the Aperio Programming Application manual ref 1 Before configuration check that default radio channels are used 11 16 and 26 On the menu bar click Settings Offline Installation settings to enter this dialog MIFARE Classic UID format Select how the MIFARE Classic UID should be Formatted in the audit trail and when configuring override credentials USB radio dongle channels Select the radio channels to use when connecting to Aperio Offline locks Hexadecimal Format i e 25A78FA4 Teste Decimal Format i e 631738276 13 2 415 GHz E Hexadecimal Format reverse byte order i e A48FA725 14 2 420 GHz 15 2 425 GHz V 16 2 430 GHz 17 2 435 GHz Decimal Format reverse byte order i e 2760877861 18 2 440 GHz 19 2 445 GHz 20 2 450 GHz 21 2 455 GHz 22 2 460 GHz 23 2 465 GHz 24 2 470 GHz 25 2 475 GHz WV 26 2 480 GHz Follow the
17. n Guide Document No ST 001322 G Date 4 July 2014 y Aperio 9 Offline Step 2 Connecting to an offline lock Follow these steps to connect to an offline lock 1 Click Connect in the Offline section of the menu bar Eile Installation Help ONLINE OFFLINE e a Quick scan Scan Refresh Connect wk Disconnect 2 Hold the radio card at the lock or remove and reinsert battery Show card engage sensor Time remaining until timeout 12 seconds Result Detailed information is downloaded and the Programming application connects to the lock File Installation Help ONLINE OFFLINE e e a lt lt Quick scan Scan Refresh Connect Disconnect AN agarig Lock Lock Id Lock Group Lock 019966 MAC Address Physical location Radio channels Active Channel Security mode Site code Toggle Mode Default Scheduled Open Start Time End Time Door Information Lock Id Lock Group MIFARE Classic Configuration Total number of sectors Number of alarm sectors Number of Scheduled Open sectors System sector Used sectors 00 17 7A 01 02 01 99 66 Office A 11 16 26 26 2 480 GHz Customer Mode 42 USB radio dongle COM 7 Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline Step 3 Configuring locks Wizard This instruction describes a default configuration of a lock and includes the fol
18. n the table below that you want to save Then choose a name for the setting and click OK to save Configuration name Floor 1 Offline Lock configuration r Include Configurations Time zone Daylight saving time data Time and date UTC Default scheduled open MIFARE Key Security mode Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 15 Aperio Offline 16 3 Exclude configurations settings by clicking the check boxes Only save settings that are general for all locks in your installation A recommendation is a RFID configuration b Change security mode c Device time update d And optionally some advanced features like Battery Alarm Status configuration and Locking parameters 4 Click OK Result The configuration is saved in the local storage and you are back in the Configuration Wizard Choosing Cancel on the Device Update page does not affect the locally stored configuration 5 Click Next to download the configuration to the lock 6 Hold the radio card at the lock or remove and reinsert battery Device update result The result of the device update will be presented below Show cardiengage sensor Time remaining until timeout 14 seconds o o OCOU n QoQFRAaaM mQ gt U 4 Bak Acoe Cancel Aperio Offline
19. ock details through imported data by using menu option File Manage Offline Lock Identification Data All the fields are mandatory Both Lock id amp group accept max 5 digits Physical location should not be more than 21 characters Current RFID configurations allow lock group field max value to be 96 Select lock details using Imported data M Physical Location Office A Lock Id 2 Lock Group 1 b Imported data This is an advanced option where imported door data XML format can be used to configure locks see ref 1 ST 001321 Aperio Programming Application manual Change lock identification details manually or through imported data Enable choosing lock details through imported data by using menu option File Manage Offline Lock Identification Data All the fields are mandatory Both Lock id amp group accept max 5 digits Physical location should not be more than 21 characters Current RFID configurations allow lock group field max value to be 96 Select lock details using Imported data Manually Physical Location Group MAC Address Office B Office B Floor 3 Lock Id 1 is available 3 Click OK Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline 4 Hold the radio card at the lock or remove and reinsert battery to download
20. r other applications than Aperio Offline Plan your sector configuration with the following limitations in mind MIFARE DESFire 2K MIFARE DESFire 4K MIFARE DESFire 8K Max lock groups 4000 8096 16288 Max alarm slots 250 506 1018 Max scheduled openslots 500 1012 2036 Having max lock groups means no alarms and vice versa since they share the same storage space on the credential Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline General settings General Settings General settings for the lock Select an appropriate time zone Lock time amp daylight saving data will be calculated on the basis of selected time zone Time zone settings Time zone UTC Greenwich Mean Time Europe Dublin B code settings Site code settings Each site has a unique code that all credentials within the system share It is a mandatory field on the screen where the user is allowed to enter up to 4 bytes 9 10 digits Time zone settings Select the time zone where the access system is located Configure Scheduled Open settings amp schedules Configure Scheduled open settings amp schedules Provide start and end interval time for scheduled open settings Uploading schedule xml data to the lock will set schedule for the lock Change scheduled open settings Scheduled open Start Time 07 00 End Time 17 00 r Upload s
21. reless lock aperio technology x
22. sectors Number of Scheduled Open sectors Sector number Physical number Sector type System sector Default X X Alarm Scheduled Open Default 10 Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline MIFARE Classic configurations is a part of the lock setup information that describes the sector layout of access cards used on the site This configuration screen allows the user to specify a MIFARE B key and configure the MIFARE sector usage alarm sectors and schedule open sectors e If MIFARE Classic RFID configuration is done wrong the lock may become inoperable Key configuration MIFARE Key B Enter the 6 byte long hexadecimal MIFARE Classic Key B that applies for the user cards in your installation Example AABBCCT 12233 Sector configuration Total number of sectors Enter the total number of sectors to be used on the card Number of alarm sectors Enter the number of alarm sectors reserved on access cards used on the particular site Number of scheduled open sectors Enter number of scheduled open sectors reserved on access cards used on the particular site After adding the number of sector used click the Physical number drop down menu to select change a physical number for each sector Physical numbers not used are free to be used by other applications System limitation The sector configuration settings affe
23. steps below to perform a default configuration of locks The changes you make during the update of the door configuration are not carried out until you perform the device update on the last page in the wizard 1 Selectthe lock in the scan result table right click and select Configure Lock Lock Id Lock Group Assigned Addr Configure Retrieve System Information Retrieve Event Log Retrieve Audit Trail Change Lock Identification Details Change Radio Channels Switch to Customer Mode Upgrade Firmware Factory Reset Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 9 Aperio 9 Offline 2 Click Next after completion of each dialog in the Configuration Wizard RFID configuration Select the tab depending upon the lock type Only one type of configuration can be sent to the Lock Click Add Change to enter the settings for each card format RFID Configuration The RFID configuration must be selected depending upon the type of firmware Changes to be sent Total number of sectors Number of alarm sectors Number of Scheduled Open sectors System sector Used sectors Remove changes Add Change 4 Back gt Next Cancel MIFARE Classic configuration r Key Configuration Key B 222222222222 r Sector configuration Total number of sectors Number of alarm
24. the Aperio hardware These and other settings are described in the Step 1 creating a new installation Aperio Programming Application manual ref 1 Step 2 connecting to an offline lock Step 3 configuring locks Wizard RFID The quick installation process does NOT configuration scheduled open setting security require that the Aperio hardware is mode configured in the EAC nor mechanically Step 4 adding lock identification data lock id installed and lock group Step 5 apply saved configuration to several locks Step 6 testing after configuration 6 Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline Preparation before quick installation Install the Programming Application on your laptop Refer to ref 1 Aperio Programming Application manual for instructions The software and encryption key file is delivered from your local ASSA ABLOY company The encryption key file is provided via encrypted e mail or on a USB memory stick Make sure that batteries are installed in the lock Step 1 Creating a new installation The first step is to create a new installation which is a password protected set of settings you need to communicate with a lock The installation is linked to the encryption file that is needed in order for the communication to work 1 Insert the USB Radio dongle and start the Aperio Programming Application 2 Select File New Installation in
25. u x oan nner Urner ree RII E UI etree Offline Lock LED Indication Lock Maintenance LED Indication Lock self test LED indiCatiOn u lk EE W Walk tnnt Sa ak R MENA Maka S CADRE CUI sa AK u uuu u eee MM When connecting to a lock During normal OP Sra ON sas y thee qaqaqa qaa Sua saa HERA Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline 1 Introduction Purpose The main purpose of this manual is to provide necessary information for a quick installation of Aperio Offline based products using the Aperio Programming Application The manual is intended for installation personnel project managers and people with similar responsibilities Scope This quick installation guide covers a standard installation of a complete Aperio offline system For acomplete description of all functionality and possible settings in an Aperio Offline installation refer to the Aperio Programming Application Manual ref 1 This manual is applicable to version 2 6 6 of the Aperio Programming Application Abbreviations and Definitions Applicable Products This manual can be used for all Aperio Offline locks Product availability The products included in this manual may not be available on all markets Please check your local ASSA ABLOY company for details Aperio support in the EAC system Note that the Aperio support may vary depending on the Aperio
26. within 2 5 s Scheduled open i it tts Four green flashes unlocked locked Z 9 gt 70 25 sec Lock mechanism is l l l l l Continuous red flashes Se w m m M a m blocked when closing I I 125 seconds every 1 sec Error in lock maintenance required 7 7 E S AS Al AA AA Ten red flashes 125 sec each VN QN IS rwv Repeated every 10 sec if lock can t close AIAN IN INCI Ten red flashes 125 sec each Tamper gt P Xia 72 Ze 71 Y repeated every 10 sec Time to replace _ Continuous yellow flashes n n 4 the battery gt Ee 25 seconds every 5 sec Battery reached end _ _ lt i Continuous red flashes of life lock disabled 9 as 25 seconds every 5 sec Figure 3 Offline lock LED indication Access cards 1 If LED or LED Buzzer is configured as card read indication an extra yellow indication will be shown compared to description above 2 When the lock mechanism is blocked lock jammed the knob must be turned to release it 3 The Error in lock indication is also shown instead of the POST flashes if the battery is not accepted as new after a power on reset ecc Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 Aperio Offline Radio activation card read UHF transceiver activated Programming Application connected to lock Figure 4 Offline lock LED indication Radio activation card Card detecte
27. ystem sector 1 Used sectors 1 2 3 4 Daviicht Savina Data USB radio dongle COM 7 Aperio Offline Quick Installation Guide Document No ST 001322 G Date 4 July 2014 19 Aperio 9 Offline 20 2 Click Confirm to start the transfer The following configuration is ready to be transmitted You might need to show a card to the lock or engage the sensor Click Confirm to transmit the configuration Time zone UTC Greenwich Mean Time Europe Dublin Daylight saving time data Time and date UTC MIFARE Key Key B 222222222222 Security mode Customer Mode Radio channels 11 16 25 3 Hold the radio card at the lock or remove and reinsert battery to download the configuration Show cardiengage sensor Time remaining until timeout 12 seconds _ _ 4 After download the result is shown The settings that could not be downloaded to the specific hardware are ignored Click OK to finish Successful Time zone Daylight saving time data Time and date UTC MIFARE key security mode Radio channels Cx 5 Add Physical location Lock id and Lock Group according to section Step 4 Adding Lock Identification Details on page 17 6 Repeat all the steps from the beginning of this section for every lock you want to configure with a saved configuration Aperio Offline Quick Installation Guide Document No ST 001