Home
Network Video Recording Surveillance System User Manual
Contents
1. power off ch 2 Do not cut off the power artificially or give shock or vibration to unit while the hard disk is activating It may cause hard disk failure or loss of data A Remarks X Pictures and buttons are subject to be changed or modified up to different models X Function or configuration is subject to be changed or modified without prior notice for improvement of the product Contents 1 GE FING STARTED EE 2 1 1 CHECKING Supplied A UC E H 1 2 SS UN ER UI cscs sec gece cece ce ses catece cee E 3 1 3 System alt Le sicscssdencasccccccaccscevancsecsanscascsiascdscsiovsdecescasdsescousscuesvansdetsdanedess anes suaigesdesassanceaadeuscedesauessbaasssuneesascasssisesastuacudceixeunscieveieas 3 1 4 SSN NAN EE 4 1 5 System OUI acisna T stan seat ee aoe ac ea ees 7 1 6 PUY TEE 7 2 INITIAL SETUP QUICK CT UTC 8 3 CUSTOM SETUP EN 11 WK WE i Sa EE ROSO E 11 Sde VOCO OCU oran A E E TAE EEE E E EE E E E EA E O 12 3 2 PR ON BEN 12 Sele SNEU SCs EH 12 See Event SeIUD EE 13 S23 INOMMCATON EE 13 3 3 INSEE urona E NEEE A E 14 3 4 e e E E E NE E 15 oP AE O EE 15 GAs NAA REN 15 3 5 EEE olge OM E 16 Sk Pee TMC EH 16 292 HDD CONOUG einn 16 35 3 Conti u raton DacCk UD MeSlOke sdisgucsndiavescinieeuestiaatuteriqutucetiqeiunotudhaurstdeeteseetaatussaien 16 308 Loca USB BACKUP geeiert EE 16 S00 MFilMWare E eet EE 16 Bom Fach RE E 17 3 6 LO e PNE E O OI ian eds eerie aaron 17 SR SVSIOMI EO EE 17 362 Event LOJ NEE 17 3 7 RUN e ai
2. follows 1 2 3 4 NOTE NOTE NOTE NOTE Select channel that selected IP camera would be assigned Enter RTSP HTTP Port amp Stream Name If it only allows registered users check Authentication and enter User ID amp Password Click Get Detail field to get information automatically such as RTSP Port HTTP Port amp Stream Name only available devices If it doesn t get information properly you should enter them manually Use Manual Registration on unsearchable devices you should know all information and enter manually All changes will be applied when click Ok button You must click Ok button when you leave this page The Check mark in the box of Status section means OR iNVR is now communicating with the IP camera properly If there is no check mark in the box please check connection status between OR iINVR amp IP Camera Once the name in Model field is changed it would be applied to the site list It takes a little time to get information after clicking Get Detail so it may be considered as no response But it is a normal operation lt much depends on the camera model and some model requires about 10 seconds 3 1 2 Video Setup Access each devices setup page in OR INVR setup page Built in web browser open pages in OR INVR setup Setup available devices shows mark on Open page field To open camera setup page web page click this field which has
3. LOGIN To RE Only authorized user is allowed to access to the web server due to security reasons When you connect to OR iNVR Log in screen is shown Default User ID is admin and Password is 1234 After log in it requires the process for calling Java program During that time Java logo will be shown on the screen And then the Quick Setup screen will be shown H The first step is for Network Setup Date amp Time Configuration and HDD Information amp Configuration User can setup those items step by step All the setting value changes including HDD format are applied after finish all setting steps 1 BELL LLL om e e jo jem fe ae jae Jom fom fete fe jem Jem fm fem bee Jee fame fee fa fem a User can search and register ONVIF based IP cameras in the second step Click Search button to search ONVIF based IP cameras which are in the same network with OR iINVR d AO Bee Gs vielegle elelegleleeleelele ele eleleiee Following is the procedure of registering searched devices 1 Select channel and assign selected IP camera 2 Enter RTSP Port HTTP Port amp Stream Name In case of the device that allows connection only for the registered users check Authentication and enter User ID amp Password 3 Incase of the device that supports detail informa
4. Network Video Recording Surveillance System User Manual X The picture amp functions amp supplied items might differ according to the specification and model Contents of this user manual are protected under copyrights and computer program laws Model OR INVRO8 amp OR INVR16 ORIGIN TECHNOLOGY Please read this User Manual and retain it for future reference WARNING TO REDUCE FIRE OR SHOCK HAZARD DO NOT EXPOSE THE UNIT TO RAIN OR MOISTURE The installation should be made by a qualified service person and conformed to all local codes Cautions Read Before System Operation Follow these details to prevent material damage or personal injury Signs of Caution and Warning A Warning This sign indicates that the user could die or be seriously wounded if not used or installed properly Caution This sign indicates that the user could be wounded or could expect property damage if not used or installed properly A Warning Do not expose the product to fog rain or too much humid to decrease danger from electric shock or fire General Warning A Warning 1 Use the power cord which is supplied or recommended by the supplier or it may cause fire 2 Do not disassemble or reassemble the product lt may cause malfunction or fire 3 Enquire to your vendor for repair It may cause electric shock or fire if the repair is not done properly 4 Do not touch the product with wet hands It may cause malf
5. a supports multi streams In order to use this function to reduce the system load the IP camera setup should be done properly 20 Full Screen User can switch to full screen 1 Double click the image 2 Select Full Screen on the pop up menu which is shown when the Control button is clicked Direct View fram Camera Relay view from NWF E YOD Full Screen Save Snapshot Channel Tour On Channel Tour Off Retresh Rate Disconnect Video 3 In order to return to normal mode from full screen mode click Exit Full Screen on the upper side of the full screen Save Snapshot User can save current monitoring image as a still image Jpeg file JPEG amp JPG Files Only Select Save Snapshot on the pop up menu which is shown when the Control button is clicked Then the screen for saving path is shown After selecting the folder and file name the image will be saved as Jpeg file format Disconnect Video It disconnects the IP camera connection of the channel Even if channel tour function is being used the relevant channel is not displayed but the channel logo is shown 3 7 3 PTZ Control lf a camera supports ONVIF based PTZ control PTZ control can be done on OR iNVR screen Control it after opening PTZ control panel 21 3 8 VOD Monitoring OR iINVR supports VOD monitoring with built in Java based WEB server Click VOD button on t
6. can install Java by clicking Free JAVA Download button in the main page of Java homepage 2 There are two versions of Java 32bit edition amp 64bit edition It should be followed to that of WEB browser edition not the OS edition NOTE n case of Windows IE Internet Explorer Java detects IE version automatically But in case of the other browsers ex Google Chrome etc it can be installed as plug in type and installation message will be shown in the browser 1 4 System Startup Network setup is necessary before using OR iINVR If you Know the assigned IP to OR iINVR you can connect to OR INVR with the IP and reset it in the setup screen If you don t Know assigned IP run IP Installer to find devices IP installer is included on CD IP Installer amp OR iINVR should be in the same Subnet Mask Device Search 1 Check if OR iINVR is placed in same subnet mask with IP Installer 2 Click Device Search button of IP Installer If TCP Port of OR INVR was changed TCP Port for search should be changed before searching devices 3 IP Installer shows device list which is connected in the same network Note When you execute IP Installer Windows may pop up warning message screen In this case you need to click Yes to run the program If there is no search result shown even though IP Installer amp OR INVR uses same Subnet Mask and OR iNVR is running please check if the firewal
7. cel giae EE 18 EE NOE aa EE 18 37 2 DEUPEACh RE nn 18 Pee P et de EE EE 20 3 8 VOD MOTE OE IA eege 21 1 Getting Started Thanks for purchasing OR iINVR OR iNVR is Network Video recorder from various ONVIF based IP devices and supports remote playback A transmission data OR iINVR is working on Java platform and provides browser free in monitoring amp setup in various WEB browsers 1 1 Checking Supplied Items Make sure that you have following items supplied with your DVR If any of these items is missing or damaged notify your vendor immediately Keep the packing utilities for moving or storage purposes afterwards Items Photo Quantity 3 1 2 System Requirements Windows OS 98 Windows 7 ornigner Windows Tange DAN _ E e 2 Lem with Independent VGA card with Independent VGA card MAC OS GB aga SS M T a Independent VGA card an Independent VGA card Linux Category OS y Linux 2 6 or Higher d t 2 6 or Higher pier Sie Gen Gore 7 3rd Gen Core i7 DAN ab e e 1280x1024 or Higher 1366X768 or Higher with Independent VGA card with Independent VGA card Java version 7 or Higher Java version 6 or Higher 1 3 System Preparation OR iNVR is working on a Java platform Java runtime should be installed in the PC If this is not installed in your PC install Java The latest version of Java can be downloaded from the webpage http java com NOTE 1 User
8. click Apply button 2 If the port is changed the port should be applied to the remote software in order not to have connecting problem IP Setting Multiple Devices IP Installer can assign a specific range of IP address to multiple OR iINVR automatically 1 Check the IP address to be assigned to OR iINVR preventing from IP confliction 2 Click Device Search button and search device in the same Subnet Mask 3 Input Password for the admin account 4 Click Assign IP address Multiple Devices button to open IP assignment screen EI P installer File Command About No of detection 4 LLLLLLLLLLLLI Admin Account ID Password Port Setting Web Port 80 9010 TCP Port 5 Select Assign following IP address Static IP If you want to get the IP automatically select Obtain 192 168 107 55 metteg 2 Nic De ASEA NVR s E E 109 74 16 Static Step 2 1 0 0 MCU 5 3 0 1 1 22 MCU 5 5 0 1 1 2 MCU 4 7 0 192 168 107 1 192 168 109 1 192 168 107 1 00 1C 84 2E 2B EF 00 1C 84 2E C8 49 00 1C 84 01 4D FD 255 255 255 0 255 255 255 0 255 255 255 0 Lamae IRRIERIRRIRII EIERE RRRRIRE Assign IP Address Single Device Obtain IP address automatically DHCP Assign the following IP address Static IP 192 168 107 1 Assign IP Address Multiple Devices Subnet Mask Gateway Go to Web Configuration Mac Address IP address auto
9. ed data If you want to delete all data you need to format HDD and start factory default 3 6 Log User can search System Log and Event Log 3 6 1 System Log User can search system log such as Video Loss disconnection of IP camera Connection history Log in history and so on Set time to search and click Search button to start log search 3 6 2 Event Log User can search event log such as Video Loss disconnection of IP camera Sensor detection Motion detection and so on Set time to search and click Search button to start log search Image Monitoring OR iNVR supports Java based image display at the various browsers through built in WEB server 3 7 Live Monitoring Check the registered camera list in the main screen Select a site and drag amp drop it into an empty screen to start connection Icons which are shown in the list mean as follows IP camera is registered and connected to OR INVR IP camera is registered but not connected to OR iINVR IP camera is not registered Use the control bar on the top of each image Stretch image to fill the image screen 3 7 1 Screen Mode User can change screen mode From Single to 16 display mode To make full screen double click desired channel In order to return to the previous screen mode double click the full screen image or uncheck Full Screen in the menu that is shown when the Control button on the top of the screen is clicked I
10. erver uses SSL encryption BUZZER Check whether you use built in buzzer when the event triggered or no REMOTE NOTIFICATION It is set for network notification to the remote software A ON OFF Check whether you use this function or not B SERVER Input IP address of the PC which will receive the notification The remote software should be running in the PC AMU OWE NOTE All changes will be applied when click Ok button You must click Ok button when you leave this page 3 3 Network It is for Network setup for OR iINVR After finish the setting IP address of OR iNVR will be changed Therefore user needs to connect through the new IP address 1 Network Type A Select either Static IP or DHCP for dynamic IP B Default is DHCP for easy connection C However IP address of OR INVR can be changed by network condition it is recommended to use fixed IP Static IP 2 IP Address Enter IP adress information of this system when you need Generally all these information is entered when you search this by IP finder utility Tor more details about IP information ask your network administrator 3 WEB port A Setup WEB port for connecting to OR INVR through browser Default is 80 changeable Followings are the examples of how to connect i In case of 80 http IP address ii In case of 8088 http IP address 8088 In order to connect to OR iNVR from the outside port forwarding should be requ
11. ff the power shift the power on the rear side of OR iINVR to off position About 3 seconds later OR INVR goes to shutdown mode Since System Shutdown take a little time please wait until the system is turned off completely Note Do not turn off by unplug power cable It may cause damage to the device as well as recorded data Note Before shutdown the system make sure that it is not on firmware upgrading If the system shutdown during firmware upgrade it may cause serious damage to the device 1 6 Factory Default User can make factory default of OR INVR Push WS button on the rear side for about 3 seconds Then OR iNVR goes to factory default mode After making factory default IP address setting should be done again 2 Initial Setup Quick Setup When the power is supplied to OR INVR boot up process is started automatically Boot up process takes time depending on the situation However in general it is finished within 3 minutes OR iINVR supports Java based Web browser setup User can connect to OR INVR and control amp setup it through WEB browser If there is DHCP server in the network and OR iNVR is connected to the network IP address is automatically assigned to OR iNVR after booting NOTE Assigned IP can be checked with DHCP server or IP Installer At the first connection to OR iNVR it goes to Quick Setup mode In the Quick Setup mode network setting amp camera connection setting is available USERID
12. he top or click VOD tab Select a site and drag amp drop it into empty screen to start connection Date amp Time can be selected with search bar in the bottom or calendar which is opened when the VOD Controller tab is clicked Note Screen mode works the same as that of Live Monitoring Note When the date amp time is changed at the calendar or Intelligent search bar the date amp time of all the VOD connected channels is changed Note VOD connection amp date time change takes some time Since it is caused by buffering data at OR iNVR please wait for a while 22 4 Q amp A Q gt o Po I installed Java and connect to OR iNVR but the message pop up and no screen display is shown 1 Java has two editions 32bit amp 64bit The proper edition should be installed according to the WEB Browser It it not related to the edition of the OS When you connect to http java com through WEB Browser to be used to connect to OR iNVR the proper edition will be downloaded automatically 2 In case of the other browsers such as Chrome Firefox and Safari you can download it at the Browser as plug in type 3 OR iNVR is suitable for Java 7 version It might not be possible to work properly with the lower version When I connect to OR iNVR which is in the different network no image is displayed 1 Port forwarding should be required to OR iNVR A WEB port Default is 80 It can be changed B BASE por
13. ilable or the network traffic at the camera is heavy user can connect through OR iINVR B Inthis case View from NVR is shown on the control bar Direct View from Camera C User can choose this method by selecting Relay View from NVR Ee on Control the pop up menu which is shown when the Control button is clicked Channel Tour If user wants to monitor all sites in sequence select Channel Tour On button on the pup up menu To stop the channel tour select Channel Tour Off button on the pop up menu Refresh Rate FPS 30 Refresh Rate 30 H 264 AME SMPEG 4 AVL f MPEG 4 part 10 1920 1080 User can control display frame rate of each channel lt is only for controlling frame rate which is displayed at the WEB Browser and doesn t related to the recording frame rate It is helpful for reducing system load on the PC in case of high resolution site 1 AA Active Adjustment A It displays with full frame when a channel is selected focused B It displays only key frame when a channel is not selected focused 2 FF Full Frame A It displays with full frame regardless channel selection focusing 3 KF Key Frame A It displays only key frame regardless channel selection focusing Stream User can select stream of the connected IP camera when the channel is connected directly to the IP camera Note Stream selection function is available only in the case that the camer
14. ired 4 Base Mobile Port A Setup port for transmitting images from OR iINVR to remote software B Default is 9010 and it can be changed Once this has changed port setup at the remote software should be changed 5 MAC Address Displays MAC address 6 Event Port Set port for event transmission and this uses fixed port 8003 Receiving event from IP camera may not be available depending on the protocol of IP camera Receiving event from OR iNVR is available only at the remote software that is provided with OR iINVR 7 RTSP port Default is 554 and it can be changed It supports connection with the other ONVIF based software and the RTSP port between OR iNVR and the software should be the same 8 DDNS Use Check whether you use DDNS or not A DDNS Type Select DDNS type B DDNS port Set port to connect to DDNS Port number which is designated by DDNS service provider can be used C DDNS Domain Set the subdomain to use DDNS In some case you need to register in advance 15 D DDNS ID Input ID of the registered DDNS E DDNS Password Input Password of the ID NOTE All changes will be applied when click Ok button You must click Ok button when you leave this page 3 4 User Management lt is the menu for setup administrator password amp user registration 3 4 1 Administrator Password management page of administrator Use this page when change password as new 3 4 2 General Use
15. l option is on In this case stop Windows firewall or related program and try it again And IP Installer searches devices with broadcast method So please also check if the firewall or router or switch doesn t allow broadcast communication For the detail please consult your network administrator 5 IP Setting Single Device 1 Check the IP address to be assigned to OR iINVR preventing from IP confliction 2 Click Device Search button and search device in the same Subnet Mask 3 Click OR iINVR in the searched device list 4 Input Password for the admin account Default is 1234 5 Select Assign following IP address Static IP If you want to get the IP automatically select Obtain IP address automatically DHCP and click Apply button 6 Input IP address Subnet Mask amp Gateway and click Apply button to apply IP address to OR iINVR BP installer File Fee About 00 10 84 2F 28 6 255 0 92 168 107 0 0 00 1C 84 2E 2B EF 255 255 255 0 192 168 107 1 1 0 0 5 3 0 00 10 84 2E C8 49 255 255 255 0 192 168 109 1 1 1 22 MCU 5 5 0 00 1C 84 01 4D FD 255 255 255 0 192 168 107 1 1 1 2 MCU 4 7 0 No of detection 4 CITI LLL RIIT Admin Account son IP Address Single Device ID dn f Obtain IP address automatically a Password Port Setting Web Port 80 TCP Port 90 10 Note 1 Web Port amp TCP Port can be changed If you want enter Port and
16. mark After click log in and access setup information NOTE May not compatible if there s restriction in using Active X control 3 2 Record Set recording Schedule event setup and notification in this menu 3 2 1 Schedule Setup Set recording schedule of OR iINVR amp How to set Schedule naa age a MESSE NOTE Select one of record mode top of right Select time block To select all press All on top of left Press day button to apply whole day as same mode Time button is same as day button Colors of each recording mode A White No Record Yellow _ Continuous Green mmm Motion Orange mm Sensor Pink mmm Motion Sensor All changes will be applied when click Ok button You must click Ok button when you leave this page 13 3 2 2 Event Setup Set Sensor Motion Alarm Out relay amp Video Loss options in this menu l NOTE Sensor Assignment A Link sensor to each channel B Ifa certain channels are selected for each sensor those channels are linked with the sensor C Sensor detection recording time follows the set in the Record Duration and the unit is Minutes D It works only when the recording schedule is set as Sensor or Motion Sensor Motion Detection A Set motion detection function on each channel B Only works when recording schedule is set as Motion or Motion Sensor C To u
17. matically DHCP 6 Input the range of IP Address If you select a device in the list the current value of the device will be shown 7 When the Update button is clicked New Address which will be applied is shown It is not applied yet 8 By clicking arrow button in the left side the order of IP Address can be changed After changing order click Update button to see New Address changed 9 When the Apply button is clicked New Addresses are applied to the devices Step 5 Step 6 8 Assign IP Address Multiple Devices e o Sa Obtain IP address automatically DHCP Assign the following IP address Static IP IP Address e 168 107 55 wv fo A Subnet Mask 255 255 255 0 g Gateway 192 168 107 1 IP Address N Subnet Mask Pi 255 255 0 Update y Gateway Current Address 00 1C 84 2E C8 49 192 168 109 74 00 1C 84 2E 2B EF 00 1C 84 2E 2B B2 192 168 107 56 DVR 16 192 168 107 44 NVR IDVR 16 00 1 84 01 4D FD 192 168 107 555 DVR 8 8 Remove Note 1 2 If the device is not shown in the list or there is a device that is added later click lf there is a device that you don t want to change the IP address of it select the device and click Remove button Then IP address for the device will not be changed Refresh button to refresh the list 7 1 5 System Shutdown To turn o
18. n order to view with full screen mode click Full Screen button a In the full screen mode click Exit Full Screen to return to the normal screen 3 7 2 Setup each Channel User can control each channel setting such as connection method and so on during live monitoring Control Bar Display By clicking button user can display or hide the control bar of the channels Default is display of the control bar When LC button is clicked control bar is displayed When SS button is clicked control bar is hidden Site Change 19 If user wants to change into the other channel click KID button to move the desired channel It follows the number of site list and site number is shown on the right side of the control bar Connection Method Change User can choose the connection method between two ways direct connection to IP Camera or connection through OR iNVR It is for choosing the better way depending on the network traffic or performance of OR iNVR amp IP Camera 1 Direct connection to IP Camera A Connection to the IP Camera is made with its information registered in OR INVR B In this case View from Camera is shown on the control bar Direct View fram Camera C User can choose this method by selecting Direct View from Camera Relay iea Mom MR E on the pop up menu which is shown when the Control E button is clicked 2 Connection through OR iNVR A Incase that the direct connection is not ava
19. nction or fire 4 Do not touch the product or the power cord when there is thunder It may cause electric shock 5 Do not install the product near or on top of heating source The internal temperature of the product would be greater than allowable and could cause malfunction or fire 6 Do not install the product on inclined or unstable location or where vibration could be committed It may cause malfunction Cautions about the Power A warning 1 Must use the outlet of the grounding to connect the power cord or it may cause fire 2 Do not connect on the middle of power cord or use extension cord lt may generate heat or cause fire 3 Do not touch the power cord with wet hands lt may cause electric shock 4 Keep power cord dry and protect from humidity lt may generate heat or cause fire The power cord is not waterproof 5 Hold the body of the plug while removing the power plug Do not pull the power cord Damage to the power cord may generate heat or cause fire 6 Check the power plug regularly Humidity and moderation in smoking may cause fire 7 Remove power cord from outlet when product is not used for a long time lt may cause short circuit or electric shock AY Caution Do not turn off the power by removal of the power plug To turn off the power click the power button from the front panel When the system stops abnormally the power button might not work Click power button for 5 full seconds to turn
20. r A Add user as default permission Password E OK Cancel Administrator can add general users General users can use image monitoring only Quick Setup amp Custom Setup are not allowed to general users Administrator can add new users amp edit the setup with the following steps Click Add button in the bottom to add new user A ID Input ID of new user to be added B Password Input password of the new user C Confirm Input the password again to make sure Select channels and function which will be allowed to the user and click Save button The user s password can be changed by clicking Modify button The user can be deleted by clicking Delete button 1 wh 3 5 System Operation User can set various system operation related value in this menu 3 5 1 Date amp Time Set date amp time information To set time correctly don t forget to set Timezone amp Daylight Saving Time where available Note When the Sync with PC button is clicked time information of OR INVR becomes synchronized with that of PC 3 5 2 HDD Configuration HDD Model Mounted Format All HDDs SNE oomo arao E e o oe o es User can check HDD conditions and format it This displays information such as HDD conditions of HDD model Total Capacity Remained Capacity Used Capacity File System and installing connection status Format can be made with follo
21. se this IP camera should have motion detection function and notify it to OR iNVR Relay Assignment A Set relay output on OR iNVR B When event triggered in channel relay output works C To use this IP camera should have event function motion detection sensor detection video loss and so on Video Loss amp Miscellaneous Event A Alarm triggers when OR iNVR amp IP camera connection is unavailable due to some reasons B In case of IP camera when the network is disconnected by some reason it regards it as Video Loss In case of Event Setup changes will be saved individually That is Save button of each function should be clicked before move to another page 3 2 3 Notification Set event notification function for when event triggered in OR iNVR Event notification goes through e mail amp network remote In order to notify event through network IP address of the PC that will receive the notification should be designated and the remote software should be running in the PC esch EVENTS Select event to be notified It is applied to both e mail amp network remote notification E MAIL NOTIFICATION It is set for e mail notification ON OFF Check whether you use this function or not SERVER Enter server to send mail SMTP PORT Enter SMTP port of server to send mail ID Enter ID that is registered in the server to send mail PASSWORD Enter Password of the ID SSL Select it if the mail s
22. sers and No of current users Firmware upgrade can be done with the following steps 1 Click Select button to find a firmware file 2 Click Upload button to upload the selected firmware file to OR iINVR 3 When the Write button is clicked firmware upgrade starts Note Do not turn off the power of OR iNVR while it is being upgraded Otherwise it may cause serious damage on the system Note Firmware upgrade status can be checked through the progress bar If it is stopped and there is no more progress for about 10 minutes close the browser and reconnect to OR iINVR And then try again If the network of OR iNVR is set as DHCP IP address might be possible to be changed and the connection cannot be made In that case please check the IP address of OR iINVR Note Firmware upgrade can be made by CMS software either 3 5 6 Factory Default User can make OR iNVR to factory default Factory default can be made with the following steps 1 Enter Admin Password 2 If you want to keep the current network configuration after making factory default check Keep Network Configuration box 3 When the Reset button is clicked OR iNVR starts factory default Note All the configuration data will be lost with Factory default If Keep Network Configuration box is not checked before starting factory default current network seiting will be disappeared either Note Factory default doesn t delete sav
23. t Default is 9010 It is for Remote Software or Mobile Viewer connection It can be changed C RTSP port Default is 554 It is for general RTSP viewer or WEB browser image transmission It can be changed 2 Try to change connection method A Default connection method is direct connection to the IP Camera B Try to connect to OR iINVR by selecting Relay View from NVR in the menu that is shown when the Control button on the top of the screen is clicked Image is not displayed smoothly 1 Check the specification of the PC Each channel image display requires the same resource as that for playing movie of the same image size 2 Check the network condition In case that the network devices cannot cover the traffic there might be frame loss upgraded the firmware but Java screen is not changed 1 There is the temporary internet file which is used at Java And saved Java application program for OR iNVR is being used 2 Close all browsers and go to Control Panel gt Java After deleting temporary internet file and try to connect to OR iINVR again 3 After the temporary internet file is deleted Java application program is downloaded again when you connect to OR iINVR And it may take time to connect 4 Ifthe problem is not solved please try to connect again after deleting temporary internet file of both Java amp browser
24. tion response function user can get information of RTSP Port HTTP Port A Stream Name by clicking Get Detail button However Get Detail cannot get Authentication information and user needs to enter them manually When registration is finished click Next Step button to move to next page NOTE t would take time to get information with Get Detail Its device dependent Some camera models and others would requires 10 seconds around The final step shows the setting values which the user set at the earlier steps lf there is nothing to be changed close the setting by clicking Finish button If there is something to be changed click Previous Step button to go the setting page and change setting When the Finish button is clicked all the setting values are applied and HDD format is started lt takes time depends on the number of HDD to be formatted Note User can change the setting with Quick Setup function whenever it requires 11 3 Custom Setup OR iINVR supports Java based Web browser setup User can connect to OR INVR and control amp setup it through WEB browser User can register IP devices to OR iNVR and set up through built in Web component 3 1 1 Registration Click Custom Setup and go to Registration screen Display registered camera device list To add more camera device click Search button and add more devices To register IP cameras do as
25. unction or electric shock 5 Product installation must be ensured to a professional for product installation or it may cause malfunction electric shock or fire 6 Ground applies to video products equipped with a 3 wire grounding type plug having a third grounding pin This plug only fits into a grounding type power outlet If grounding is not done it may cause malfunction or electric shock 7 Ground connection must not touch gas pipe water pipe or telephone line If grounding is not done properly it may cause electric shock 8 Prevent metallic foreign substance from going inside the product lt may cause malfunction or electric shock 9 Do not spray insecticide or flammable spray while driving lt may cause fire 10 Place the system in a open place where air ventilation is guaranteed or it may Cause over heating and seriously damage the system to be fired 11 Prevent water from instilling inside electrical parts Clean with a dry towel or malfunction or electric shock could result A Caution 1 Use the power cord which is supplied or recommended by the supplier The internal fan rotates at high speed and may cause an accident 2 Do not drop give strong vibration or shock to the product It may cause malfunction 3 The air inhaler of the front panel and air outlet of the back panel must not be blocked during installation The internal temperature of the product would be greater than allowable and could cause malfu
26. wing steps 1 Click Format All button in order to format all HDDs which are installed in OR iNVR 2 Click Format button of each HDD in order to format that HDD 3 5 3 Configuration Backup Restore Backup OR iNVR configuration and restore Press Backup button and save configuration file When restore click restore button and select backup file No network setup will be changed 3 5 4 Local USB Backup User can backup data from OR iINVR to USB memory Following steps are for backup 1 Insert USB memory to the USB port of OR iINVR 2 Select start point amp end point and channel to backup 3 When the Backup button is clicked OR iNVR starts detecting USB memory And if OR INVR detects USB memory message will be shown 4 OR iNVR compares the remaining capacity of the USB memory with the capacity to backup If the remaining capacity of the USB is enough to backup message will be shown Then click OK to start backup Note USB Memory should be formatted by FAT 32 Note Backup start message will be remained during backup When the backup is finished it will be disappeared Note Ifthe backup is not made the reason of the failure will be displayed Please check if the backup is not made 3 5 5 Firmware Upgrade User can upgrade firmware of OR iINVR 17 In the firmware upgrade menu you can check the current system information such as IP Address Firmware Version MCU Version Maximum u
Download Pdf Manuals
Related Search
Related Contents
Samsung DVD-HR720 MP3 Player User Manual ROBOT魂 SIDE ovid ウォクス・アウラ 取扱説明書 258.0 KB AeroMaskG Equine System ("ES") Sony CDP-CX681 Operating Instructions KonneXion - Kit Videocitofonico "取扱説明書" Chapter One Safety Information Manual - KanexPro SMOKE AND FIRE ALARM USER`S GUIDE 9 Volt Copyright © All rights reserved.
Failed to retrieve file