1. e 7 0 7 5 mm ID for nasal intubation e 8 0 9 0 mm ID for oral intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices Air Bronchi The AirSim Bronchi unit will provide a solution to your training needs in e Diagnostic bronchoscopy e Lung isolation techniques using left and right endobronchial tubes and bronchial blockers e Lung suctioning techniques e For clinicians and industrial clients the AirSim Bronchi is a leading choice for demonstration of items such as e Fibreoptic bronchoscopic equipment e Single and double lumen tubes and bronchial blockers 33 e Specialised bronchial stents The AirSim Bronchi can also be used in a similar manner to the AirSim Multi and can cover an extensive range of training requirements Trucorp recommend the following equipment sizes for optimal performance e 7 0 7 5 mm ID for nasal intubation e 8 0 9 0 mm ID for oral intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices e Size 35F 37F for endobronchial tubes Air Advance The AirSim Advance can be used in the training of all the procedures facilitated by the AirSim multi which includes e Naso tracheal intubation e Awake fibreoptic examination e Bag amp mask ventilation techniques TruCorp recommend the following equipment sizes for optimal performance e 7 0 7 5 mm ID for nasal intubation e 8 0 9 0 mm ID for ora
2. dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents 18 Quick Set up Guide Air Advance and Air Advance Bronchi Remove the AirSim unit from the black carrier case with the lung bags Connect the lung bags to the open end bronchus sections of the AirSim airway The Bronchi model comes with the lung bags already attached Attach a lung bag onto the oesophagus to illustrate stomach inflation Ensure that the tongue is inflated with approx 20ml of air This will create normal lingual tension Increasing the amount of air will create a more difficult airway management scenario Using Trucorp s silicone lubricant ensure that the internal airway and Nasal passage are well lubricated Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the AirSim airway Please ensure that the AirSim airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed The head and neck skin of the models are made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material Please replace the models unit back into the car
3. one piece and seamless construction for real life functionality roaucing the Airsim Range AirSim Standard The AirSim Standard is uniquely constructed to allow realistic feedback during airway management procedures and provides true anatomically correct and visually accurate internal features The neck construction allows the head to be moved and secured in a number of positions This ranges from the standard sniffing position to more difficult scenarios The AirSim Standard also features an inflatable tongue with real life size and texture There is also an option to include breakout teeth to simulate the effects of bad practice in laryngoscopy Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 3 Blue adult lung bags AirSim Multi The AirSim Multi is uniquely constructed to allow realistic feedback during airway management procedures and provides true anatomically correct and visually accurate internal features The addition of a nasal passage and chin facilitates training in nasal intubation procedures as well as bag and mask ventilation techniques Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 3 Blue adult lung bags AirSim Bronchi The AirSim Bronchi provides internal anatomically correct features down to th
4. that the internal airway and Nasal passages are well lubricated Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the AirSim airway Please ensure that the AirSim Baby and Pierre Robin airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed The head and neck skin of the AirSim Baby and Pierre Robin is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material Please replace the AirSim Baby and Pierre Robin unit back into the carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents 31 Quick Set up Guide Air Child Remove the AirSim Child from the black carrier case with blue lung bag Connect both ends of the lung bags to the open sections of the bronchi Using Trucorp s silicone lubricant ensure that the internal airway and Nasal passage are well lubricated Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used
5. to cover the surfaces in contact with the AirSim airway Please ensure that the AirSim Child airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed The head and neck skin of the AirSim Child is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material Please replace the AirSim Child unit back into the carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents 32 Airway Management Air Standard The AirSim Standard is ideal for training in the use of e Laryngeal Masks e Full range of supraglottic devices e Laryngoscopes e Tracheal Tubes e Fibreoptic Laryngoscopes e Needle Cricothyroidotomy Systems TruCorp recommend the following equipment sizes for optimal performance e 8 0 9 0 mm ID for oral intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices Air Multi The AirSim Multi can be used in the training of all the procedures facilitated by the AirSim Standard with the addition of e Naso tracheal intubation e Awake fibreoptic examination e Bag amp mask ventilation techniques TruCorp recommend the following equipment sizes for optimal performance
6. 1 Remove the AirSim unit from the black carrier case with the lung bags 2 Connect the lung bags to the open end bronchus sections of the AirSim airway The Bronchi model comes with the lung bags already attached 3 Attach a lung bag onto the oesophagus to illustrate stomach inflation 4 Ensure that the tongue is inflated with approx 20ml of air This will create normal lingual tension Increasing the amount of air will create a more difficult airway management scenario 5 Each model shipped will be able to begin usage immediately with the addition of the appropriate vocal cord insert but please ensure that the larynx is in its secured resting position and that the skin is attached to all the Velcro points to enable a fully functioning product 6 Ensure that the shelf accompanied with the model is secured and positioned correctly so that it is facing away from the head so that the laser securing apparatus can be mounted Also please ensure the screw nut is secured and in place 7 When choosing on the appropriate vocal cord insert please ensure that if a laser is being used for laser techniques that only to use the TLT material serial codes LVC This material has been tested to not give out toxic fumes upon Co laser ablation and is safe to use Using a CO laser on the silicone surgical inserts will be potentially harmful and your warranty will be affected and you will not be viable for replacements 8 When choosing the voc
7. AirSim User Manual Version 4 3 tru true training t t corpo rue anatomy true to life Table of Contents Introduction Introducing the AirSim range Quick set up guides AirSim Standard Multi amp Bronchi AirSim Advance AirSim Advance Bronchi AirSim Advance Crico AirSim Advance Crico Bronchi AirSim Advance Traci AirSim Advance Traci Bronchi AirSim Advance Combo AirSim Advance Combo Bronchi AirSim Advance Larynx AirSim Baby AirSim Pierre Robin AirSim Child Airway management Care and maintenance Warranty 18 19 19 21 21 23 23 25 25 27 31 31 32 33 40 41 Designed and produced by TruCorp the AirSim range brings highly realistic and fully functional airway training systems to the market The main and most important component of the AirSim range is the unique AirSim airway This is a faithful reproduction of the human airway anatomy and as such is invaluable as a training aid to facilitate the learning and development of airway management skills for all health professionals The innovated development and manufacture approach used makes the AirSim airway unique The main features of the AirSim Airway which makes it unique include The airway is moulded from a master which was created from data collected from a CT scan of a person The one piece mould together with the sophisticated dipping procedure during manufacture makes possible much of the realism offered Integrated
8. TruCorp recommend the following equipment sizes for optimal performance e Size 3 5 4 tracheal tubes e Size 1 for LMA laryngeal masks similar respective sizes for other supraglottic devices e Size 1 for video laryngoscopes Air Child The AirSim Child can be used in the training of all the procedures facilitated by child airway management which includes e Naso tracheal intubation e Positive pressure ventilation e Bag amp mask ventilation techniques Endotracheal intubations TruCorp recommend the following equipment sizes for optimal performance 39 e Size 5 5 6 oro tracheal tubes size 4 5 5 0 naso tracheal tubes e Size 2 for LMA laryngeal masks similar respective sizes for other supraglottic devices e Size 2 for video laryngoscopes Care and Maintenance Cleaning and Storage Store in clean dry conditions away from heat and direct sunlight avoid contact with metals solvents oils or greases and strong detergents Thoroughly wash the AirSim airway in warm water using a dilute 8 10 w w sodium bicarbonate solution until all visible foreign matter is removed Mild detergents or enzymatic cleaning agents may be used on the airway in accordance with the manufacturer s instructions and at the proper dilution The detergent must not contain skin or mucous membrane irritants Clean the device using a small soft bristle brush approximately 1 2 inch or 12 5mm in diameter Gently insert the brush through t
9. VC P2 Polyp 2 Two small polyps opposing on the vocal cords SVC C2 Cancer 2 One single large Tumour LAR200 Larynx cover RS1005 Overlaying Neck Skin Attachments pack of 5 29 Disclaimer The AirSim Advance Larynx has materials that with misuse or misdirection of a laser can cause very damaging effects to the model and destroy the outer silicone facial skin and the internal latex airway Also there is a high risk chance of fire damage to the models when exposing the laser to the areas mentioned above other than on the vocal cord inserts The vocal cord inserts should be the only area that is in direct contact with the laser Misuse or application of the laser at any other location on the model other than the designated TLT vocal cord insert will result in warranty being void The laser should only be used for the TLT vocal cord inserts and not the silicone vocal cords inserts Again this would make the warranty void Adequate ventilation is required when using the model in a theatre environment when ablating the TLT inserts with a CO laser The potential gases released have not been fully characterized and please ensure minimal exposure 30 Quick Set up Guide Air Baby and Air Pierre Robin Remove the AirSim Baby and AirSim Pierre Robin from the black carrier case with blue lung bag Connect both ends of the lung bags to the open sections of the bronchi Using Trucorp s silicone lubricant ensure
10. al cord for surgical techniques please use the silicone vocal cord inserts with serial codes SVC as these are specifically designed for surgical procedures only and NOT laser techniques 9 When ordering the vocal cord inserts please ask for guidance upon your intended purpose and we can guide you on the best inserts for your application We do advise that the inserts are only ordered as and when for demand purposes and not ordered to build up stock as the shelf life is short on the laser inserts 10 When the TLT material for laser techniques is not being used or is not needed please ensure that is it kept in the air tight 11 12 13 14 15 16 17 container The material can dry out rapidly if not stored correctly or left open We also advise not ordering delivering the vocal cord inserts until a week or two before you re intended purpose based on this fact Your warranty will be affected if the TLT inserts have found to be stored incorrectly To insert the vocal cords peel back the neck skin remove the larynx cover and in the space provided in the larynx place the appropriate vocal cords Ensuring that the lower location point lines up with the location hole in the larynx Re attach the larynx cover and secure the neck skin into please at all the Velcro locations Full care is needed when using the laser on the model and that only the vocal cord area with the TLT material is used for ablation Using Trucorp
11. brochure 1 CD user manual 1 Bottle of lubrication 1 Blue adult lung bag 2 Blue baby lung bags 1 roll of airway sealing tape 1 combo larynx cover as supplied on manikin 1 wrap around neck skin as supplied on manikin OO0000000 13 AirSim Advance Larynx KW The AirSim Advance Larynx is uniquely constructed to offer realistic training in microlaryngeal surgical and laser techniques Evolving from Trucorp s AirSim Advance Crico it has been uniquely designed to give optimal realism while training in a theatre environment The AirSim Advance Larynx comes with disposable silicone vocal cord inserts for training in surgical techniques for removing cancerous pathologies on the vocal cords It also comes with Trucorp s new specially developed TLT material vocal cords which highlight a range of cancers and polyps for the use of training in CO2 laser removal techniques Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 3 Blue adult lung bags 3 overlay neck skins 1 supplied on model and two spare 1 of each type of silicone insert O00000 14 AirSim Baby The AirSim Baby based on a 0 6 month old provides a realistic and anatomically correct peadriatric manikin for airway management training The manikin facilitates training in the use of bag mask ventilation supraglottic airway insertion and both naso and orotracheal intubat
12. ces Direct laryngoscopy Endotracheal tube insertion Awake fibre optic examination Single lung isolation techniques Combi tube insertion Video laryngoscopy including Sellick Manoeuvre Naso gastric tube insertion techniques TruCorp recommend the following equipment sizes for optimal performance 7 0 7 5 mm ID for nasal intubation 8 0 9 0 mm ID for oral intubation Size 3 5 for LMA laryngeal masks Similar respective sizes for other supraglottic devices Advance Combo Bronchi The AirSim Advance Combo Bronchi is ideal for training in Needle and surgical cricothyroidotomy 37 Air Percutaneous tracheostomy Double naso tracheal intubation Diagnostic bronchoscopy Lung isolation techniques Lung suctioning techniques Bag and Mask ventilation techniques Full range of supraglottic devices Direct laryngoscopy Endotracheal tube insertion Awake fibre optic examination Single lung isolation techniques Combi tube insertion Video laryngoscopy including Sellick Manoeuvre Naso gastric tube insertion techniques TruCorp recommend the following equipment sizes for optimal performance 7 0 7 5 mm ID for nasal intubation 8 0 9 0 mm ID for oral intubation Size 3 5 for LMA laryngeal masks Similar respective sizes for other supraglottic devices Advance Larynx and Advance Larynx Bronchi The AirSim Advance Larynx can be used in the training of all laser techniques for removing cancerous pathologies on the vocal cords using a C
13. copes e Tracheal Tubes e Fibreoptic Laryngoscopes e Naso tracheal intubation e Awake Fibreoptic examination e Bag amp mask ventilation techniques TruCorp recommend the following equipment sizes for optimal performance e 7 0 7 5 mm ID for nasal intubation e 8 0 9 0 mm ID for oral intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices Air Advance Traci Bronchi In addition to percutaneous Tracheostomy the AirSim Advance Traci Bronchi is also ideal for training in e Full range of supraglottic devices e Laryngoscopes 36 Air Air Tracheal Tubes Fibreoptic Laryngoscopes Naso tracheal intubation Awake Fibreoptic examination Bag amp mask ventilation techniques The AirSim Advance Traci Bronchi unit will provide a solution to your training needs in Diagnostic bronchoscopy Lung isolation techniques using left and right endobronchial tubes and bronchial blockers Lung suctioning techniques For clinicians and industrial clients the AirSim Bronchi is a leading choice for demonstration of items such as Fibreoptic bronchoscopic equipment Single and double lumen tubes and bronchial blockers Specialised bronchial stents Advance Combo The AirSim Advance Combo is ideal for training in Needle and surgical cricothyroidotomy Percutaneous tracheostomy Double naso tracheal intubation Bag and Mask ventilation techniques Full range of supraglottic devi
14. e fourth generation bronchi The model provides exceptional detail in both internal and external features the carina the bronchus and bronchials can be clearly identified through the use of a fibre optic laryngoscope Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 1 Blue adult lung bag 2 Blue baby lung bags AirSim Advance The AirSim Advance features the uniquely constructed AirSim airway designed to provide true anatomically correct and visually accurate internal features to allow for airway management techniques The addition of a real feel skin covering provides a more realistic bag mask ventilation training allowing for accurate articulation Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 3 Blue adult lung bags AirSim Advance Bronchi The AirSim Advance Bronchi provides internal anatomically correct features down to the fourth generation bronchi together with the addition of the real feel skin covering This model combines together the skin covering of the AirSim Advance with all the combined features of the AirSim Bronchi to provide a true anatomically correct and visually accurate trainer for bronchoscopy techniques Contents Included in the black carry case are the following items 1 Shipping br
15. he airway taking care not to damage the material Extra care must be taken when cleaning around the vocal cords Thoroughly rinse the airway in warm flowing tap water to remove cleaning residues Carefully inspect the device to ensure that all visible foreign matter has been removed The head and neck skin of the AirSim Advance is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material Germicides disinfectants or chemical agents such as glutaraldehyde e g Cidex Ethylene oxide phenol based cleaners or _ iodine containing cleaners Such substances are absorbed by the AirSim materials resulting in exposure of the user to unnecessary risk and possible deterioration of the device Do not use a device that has been exposed to any of these substances Warranty TruCorp warrants this unit to be free of defects in materials and workmanship and to give satisfactory service for a period of 1 year from the date of delivery The TruCorp warranty can now provide an additional 2 or 3 year warranty onto the products which will ensure full model repairs and returns and any other issues with the model at an extra premium price Please contact sales for more details This ensures that our customers receive maximum coverage on each product If the unit should malfunction it must be returned to the factory fo
16. he carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents Trucorp provide the following spare parts for the AirSim Advance Crico These can be ordered while purchasing using the following codes RSN1005 Wrap around Neck Skin Attachments pack of 5 LA1000 Replaceable Crico Larynx Anatomical Larynx containing the Thyroid Cartilage Cricothryoid membrane and Cricothryoid cartilage ST1000 Sealing Tape Sealing tape used to replicate the Cricothryoid membrane This interchangeable part is used to cover the cricothryoid hole in the airway and is replaced after every surgical procedure SFT1005 Subcutaneous Fat Tissue pack of 5 22 Quick Set up Guide Air 10 11 Advance Traci and Air Advance Traci Bronchi Remove the AirSim unit from the black carrier case with the lung bags Connect the lung bags to the open end bronchus sections of the AirSim airway The Bronchi model comes with the lung bags already attached Attach a lung bag onto the oesophagus to illustrate stomach inflation Ensure that the tongue is inflated with approx 20ml of air This will create normal lingual tension Increasing the amount of air will create a more difficult airway management scenario Each model shipped will be able to begin the tracheostomy procedure immediately but please ensure that the airway has sealing tape covering the Traci hole
17. ion Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 2 Blue baby lung bags 15 AirSim Pierre Robin oC The AirSim Pierre Robin based on a 0 6 month old was developed in collaboration with clinicians from Children s Hospital Los Angeles to highlight difficult airway management techniques on infants with Pierre Robin Sequence Syndrome The AirSim Pierre Robin s anatomically correct airway has been constructed from real CT data allowing realistic training in all aspects of difficult infant airway management Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 2 Blue baby lung bags 16 AirSim Child A The AirSim Child which has been developed in conjunction with the Children s Hospital Los Angeles is based on true CT data This anatomically correct 6 year old has both realistic and anatomical features perfect for practicing basic paediatric airway management skills Contents Included in the black carry case are the following items 1 Shipping brochure 1CD user manual 1 Bottle of lubrication 2 Blue child lung bags 17 Quick Set up Guide Air Standard Multi and Bronchi Remove the AirSim unit from the black carrier case with the lung bags Connect the lung bags to the open end br
18. l intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices Air Advance Bronchi The AirSim Advance Bronchi can be used in a similar manner to the AirSim Advance and can cover an extensive range of training requirements including e Naso tracheal intubation e Awake fibreoptic examination e Bag amp mask ventilation techniques The AirSim Advance Bronchi unit will provide a solution to your training needs in e Diagnostic bronchoscopy e Lung isolation techniques using left and right endobronchial tubes and bronchial blockers e Lung suctioning techniques e For clinicians and industrial clients the AirSim Bronchi is a leading 34 choice for demonstration of items such as e Fibreoptic bronchoscopic equipment e Single and double lumen tubes and bronchial blockers e Specialised bronchial stents TruCorp recommend the following equipment sizes for optimal performance e 7 0 7 5 mm ID for nasal intubation e 8 0 9 0 mm ID for oral intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices e Size 35F 37F for endobronchial tubes Air Advance Crico In addition to Needle Surgical Cricothryoidotomy the AirSim Advance Crico is also ideal for training in e Full range of supraglottic devices e Laryngoscopes e Tracheal Tubes e Fibreoptic Laryngoscopes e Naso tracheal intubation e Awake Fibreoptic examination e Bag amp ma
19. located between the 2 and 3 Tracheal ring the larynx is in its secured resting position and that the skin is attached to all the velcro points to enable a fully functioning product After a nominal amount of procedures ensure that the airway sealing tape is replaced as this will affect the airtight quality of the product The larynx can be removed easily and another piece of sealing tape cut to approx 5 6cm and attached over the Traci hole in the airway Please ensure that the airway is clean and dry before attaching the tape to ensure secure tape adhesion To ensure the larynx is in it s secure and correct resting position line up the gap on the larynx that resembles the 2 and 3 tracheal ring and line up with white sealing tape Each replaceable neck skin can be easily removed and a new piece attached To ensure a completed fully functional neck skin all velcro locations must be attached to the skin Using Trucorp s silicone lubricant ensure that the internal airway and the nasal passage is well lubricated Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the AirSim airway and the Tracheal rings 23 12 Please ensure that the AirSim airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign
20. matter and residue is removed 13 The head and neck skin of the AirSim Advance Traci is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material 14 Please replace the AirSim Advance Traci unit back into the carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents TruCorp provide the following spare parts for the AirSim Advance Traci These can be ordered while purchasing using the following codes RSN1005 Wrap around Neck Skin Attachments pack of 5 TT100 Replaceable Traci Larynx Anatomical Larynx containing the Thyroid Cartilage and tracheal rings ST1000 Sealing Tape Sealing tape used to replicate the Tracheal ring membrane This interchangeable part is used to cover the space between the 2 and 3 tracheal ring hole in the airway and is replaced after every surgical procedure SFT1005 Subcutaneous Fat Tissue pack of 5 24 Quick Set up Guide Air Advance Combo and Air Advance Combo Bronchi Remove the AirSim unit from the black carrier case with the lung bags Connect the lung bags to the open end bronchus sections of the AirSim airway The Bronchi model comes with the lung bags already attached Attach a lung bag onto the oesophagus to illustrate stomach inflation Ens
21. o laser Applicable Co laser companies are to be used for this application On top of this the model can still be used to facilitate procedures which includes Full range of supraglottic devices Laryngoscopes Tracheal Tubes Fibreoptic Laryngoscopes Needle Surgical Cricothryoidotomy Naso tracheal intubation Awake Fibreoptic examination Bag amp mask ventilation techniques TruCorp recommend the following equipment sizes for optimal performance 7 0 7 5 mm ID for nasal intubation 8 0 9 0 mm ID for oral intubation Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices 38 Air Baby The AirSim Baby can be used in the training of all the procedures facilitated by infant airway management which includes e Naso tracheal intubation e Positive pressure ventilation e Bag amp mask ventilation techniques e Endotracheal intubations TruCorp recommend the following equipment sizes for optimal performance e Size 3 5 4 tracheal tubes e Size 1 for LMA laryngeal masks similar respective sizes for other supraglottic devices e Size 1 for video laryngoscopes Air Pierre Robin The AirSim Pierre Robin can be used in the training of all the procedures facilitated by a difficult infant with congenital defects for airway management which includes e Naso tracheal intubation e Positive pressure ventilation e Bag amp mask ventilation techniques Endotracheal intubations
22. ochure 1 CD user manual 1 Bottle of lubrication 1 Blue adult lung bag 3 Blue baby lung bags Please note bag mask ventilation cannot be achieved on this model due to the closed cell Bronchi features Additional lung bags can be attached onto the bronchioles to highlight successful bag mask ventilation but please ask your distributor representative or Trucorp for this feature if applicable as this is not a product feature that comes as standard with the Bronchi range of models AirSim Advance Crico The AirSim Advance Crico combines the uniquely constructed AirSim airway with the enhanced addition of simulated cricoid and laryngeal cartilages With the added advantage of a wraparound replaceable neck skin and palpable tracheal rings the AirSim Advance Crico provides a solution for delivery of effective emergency Cricothyroidotomy training Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 3 Blue adult lung bags 1 roll of airway sealing tape 1 crico larynx cover as supplied on manikin 1 wrap around neck skin as supplied on manikin 10 AirSim Advance Traci The AirSim Advance Traci combines the uniquely constructed AirSim airway with the enhanced addition of tracheal rings and laryngeal cartilages This combination of features delivers a high quality solution for realistic Percutaneous Tracheos
23. of lubricant should be used to cover the surfaces in contact with the AirSim airway the cricothryoid membrane and tracheal rings 25 Please ensure that the AirSim airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed The head and neck skin of the AirSim Advance Combo is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material Please replace the AirSim Advance Combo unit back into the carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents TruCorp provide the following spare parts for the AirSim Advance Combo These can be ordered while purchasing using the following codes RSN1005 Wrap around Neck Skin Attachments pack of 5 CL100 Replaceable Combo Larynx Anatomical Larynx containing the Thyroid Cartilage cricothryoid membrane cricothryoid cartilage and tracheal rings ST1000 Sealing Tape Sealing tape used to replicate the Tracheal ring membrane This interchangeable part is used to cover the landmarks in the airway and is replaced after every surgical procedure SFT1005 Subcutaneous Fat Tissue pack of 5 26 Quick Set up Guide Air Advance Larynx and Air Advance Larynx Bronchi
24. onchus sections of the AirSim airway The Bronchi model comes with the lung bags already attached Attach a lung bag onto the oesophagus to illustrate stomach inflation Ensure that the tongue is inflated with approx 20ml of air This will create normal lingual tension Increasing the amount of air will create a more difficult airway management scenario The neck can be adjusted and locked using the Wing nut tensioner Using this neck lock system the head can be accurately placed in the sniffing the morning air position This is achieved when the head is moved so that the red marks on the fixed neck joint are in alignment For more difficult airway management scenarios the head can be fixed in a more forward position Using Trucorp s silicone lubricant ensure that the internal airway is well lubricated including the tongue hard palate back of the mouth and epiglottis If appropriate ensure that the nasal passage is lubricated Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the AirSim airway Please ensure that the AirSim airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed Please replace the AirSim unit back into the carrier case and store in clean
25. r evaluation Upon examination by TruCorp if the unit is found to be defective it will be repaired or replaced at no charge However this warranty is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged by excessive heat the use of sharp instruments misapplication misuse or other operating conditions outside of TruCorp s control Components which wear or are damaged by misuse are not warranted and will charged if repair has been approved Before returning any models please contact TruCorp To avoid delays please ensure the following information is available 1 Returnee s name address and phone number 2 Model and serial numbers 3 Repair instructions with potential issues with images if possible 4 Apparatus devices and number of uses on the model Please direct all warranty and repair requests inquires to The Mount Business Park 2 Woodstock Link Belfast BT6 8DD and or Tel 44 0 28 9073 7281 Fax 44 0 28 9073 7282 Every precaution for accuracy has been taken in the preparation of this manual however TruCorp neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual 41
26. rier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and strong detergents 19 Removing the AirSim Advance and AirSim Advance Bronchi head from base The head can be detached from the base by removing the 3 bolts from the underside of the base as shown below The head can be reattached to the base by attaching screws in positions 1 amp 2 before attaching 3 20 Quick Set up Guide Air Advance Crico and Air Advance Crico Bronchi Remove the AirSim unit from the black carrier case with the lung bags Connect the lung bags to the open end bronchus sections of the AirSim airway The Bronchi model comes with the lung bags already attached Attach a lung bag onto the oesophagus to illustrate stomach inflation Ensure that the tongue is inflated with approx 20ml of air This will create normal lingual tension Increasing the amount of air will create a more difficult airway management scenario Each model shipped will be able to begin Cricothyroidotomy procedure immediately but please ensure that the airway has sealing tape covering the Cric hole the larynx is in its secured resting position and that the skin is attached to all the velcro points to enable a fully functioning product After a nominal amount of procedures ensure that the airway sealing tape is replaced as this will affect the airtight quality of the product The larynx can be removed easil
27. s silicone lubricant ensure that the internal airway and Nasal passage is well lubricated if used for airway management If applicable Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the AirSim airway Please ensure that the AirSim airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed The head and neck skin of the AirSim Advance Larynx is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material Please replace the AirSim Advance Larynx unit back into the carrier case and store in clean dry conditions away from heat and light avoid contact with metals solvents oils or greases and storing detergents 28 Trucorp provide the following vocal cord inserts and parts for the AirSim Advance Larynx These can be ordered while purchasing using the following codes For laser procedures LVC C1 Cancer 1 Single small cancer on vocal cords LVC P2 Polyp 2 Two small polyps opposing on the vocal cords LVC C2 Cancer 2 One single large Tumour For Surgical procedures SVC C1 Cancer 1 Single small cancer on vocal cords S
28. sk ventilation techniques TruCorp recommend the following equipment sizes for optimal performance e 7 0 7 5 mm ID for nasal intubation e 8 0 9 0 mm ID for oral intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices Air Advance Crico Bronchi In addition to Needle Surgical Cricothryoidotomy the AirSim Advance Crico Bronchi is also ideal for training in e Naso tracheal intubation e Awake fibreoptic examination e Bag amp mask ventilation techniques The AirSim Advance Bronchi unit will provide a solution to your training needs In 35 e Diagnostic bronchoscopy e Lung isolation techniques using left and right endobronchial tubes and bronchial blockers e Lung suctioning techniques e For clinicians and industrial clients the AirSim Bronchi is a leading choice for demonstration of items such as e Fibreoptic bronchoscopic equipment e Single and double lumen tubes and bronchial blockers e Specialised bronchial stents TruCorp recommend the following equipment sizes for optimal performance e 7 0 7 5 mm ID for nasal intubation e 8 0 9 0 mm ID for oral intubation e Size 3 and 4 for LMA laryngeal masks similar respective sizes for other supraglottic devices e Size 35F 37F for endobronchial tubes Air Advance Traci In addition to percutaneous Tracheostomy the AirSim Advance Traci is also ideal for training in e Full range of supraglottic devices e Laryngos
29. tomy training Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 3 Blue adult lung bags 1 roll of airway sealing tape 1 traci larynx cover as supplied on manikin 1 wrap around neck skin as supplied on manikin 11 AirSim Advance Combo E a p The AirSim Advance Combo combines the uniquely constructed AirSim airway with the enhanced addition of simulated cricoid tracheal rings and laryngeal cartilage This combination of features delivers a high quality solution for realistic needle surgical Cricothyroidotomy and Percutaneous Tracheostomy training Contents Included in the black carry case are the following items 1 Shipping brochure 1 CD user manual 1 Bottle of lubrication 3 Blue adult lung bags 1 roll of airway sealing tape 1 Combo larynx cover as supplied on manikin 1 wrap around neck skin as supplied on manikin 12 AirSim Advance Combo Bronchi The AirSim Advance Combo Bronchi is the All in one trainer for your airway management needs providing anatomically correct detail down to the fourth generation bronchi together with the addition of our real feel skin Therefore facilitating airway management bronchoscopy cricothyroidotomy and percutaneous tracheostomy training Contents Included in the black carry case are the following items 1 Shipping
30. ure that the tongue is inflated with approx 20ml of air This will create normal lingual tension Increasing the amount of air will create a more difficult airway management scenario Each model shipped will be able to begin the cricothyroidotomy and tracheostomy procedures immediately but please ensure that the airway has sealing tape covering the Crico and Traci holes the larynx is in its secured resting position and that the skin is attached to all the velcro points to enable a fully functioning product After a nominal amount of procedures ensure that the airway sealing tape is replaced as this will affect the airtight quality of the product The larynx can be removed easily and another piece of sealing tape cut to approx 5 6cm and attached over the holes in the airway Please ensure that the airway is clean and dry before attaching the tape to ensure secure tape adhesion To ensure the larynx is in it s secure and correct resting position line up the gap on the larynx and line up with white sealing tape Each replaceable neck skin can be easily removed and a new piece attached To ensure a completed fully functional neck skin all velcro locations must be attached to the skin Using Trucorp s silicone lubricant ensure that the internal airway and the nasal passage is well lubricated Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts
31. y and another piece of sealing tape cut to approx 5 6cm and attached over the Cric hole in the airway Please ensure that the airway is clean and dry before attaching the tape to ensure secure tape adhesion To ensure the larynx is in it s secure resting position line up the gap on the larynx that resembles the cricothryoid membrane to the white sealing tape Each replaceable neck skin can be easily removed and a new piece attached and we hope that it will last up to 25 times before needing replaced To ensure a completed fully functional neck skin all velcro locations must be attached to the skin Using Trucorp s silicone lubricant ensure that the internal airway and the nasal passage is well lubricated Ensure that all airway devices are prepared to the manufactures recommendations and instructions Before insertion of the device generous amounts of lubricant should be used to cover the surfaces in contact with the AirSim airway and Cricothyroid membrane 21 Please ensure that the AirSim airway is cleaned after use Please use warm water of a dilute 8 10 w w Sodium Bicarbonate solution until all visible foreign matter and residue is removed The head and neck skin of the AirSim Advance is made from durable and very elastic polyurethane material It can be cleaned using a lightly soaped damp cloth Please do not use and detergents or cleaning agents on the skin material Please replace the AirSim Advance Crico unit back into t