Home
User Manual
Contents
1. e Please use the casters in a fixed position e Install the Soak Tank where the area around it can be cleaned easily e You are only allowed to use the Soak Tank for commercial purposes e An adequate specialist staff member has to operate the Soak Tank e Please use the Soak Tank only for its own special purpose 3 3 Electrical Connection Please learn the electrical connected value and the detailed technical data from the identification plate You will find it on the left side of the switch box The unit has always to be installed by a li censed electrician according to the local regulations In order to connect the Soak Tank to electrical power a power supply plug has to be used so that in case of emergency the unit can be discon nected e Check the correspondence of electricity kind and mains voltage with the relevant information on the type sign e Please be sure that the supply lead 3 core min cross section 1 5 o to the plug box is sepa rately protected with 16 ampere The local electrical connection has to be laid that way that an unintentional contact to hot parts is excluded e Further information please check with the circuit diagram chapter 5 3 printed 09 2010 Subject to change RF8030UserManual doc 6 Installation and Starting Up 3 4 First Operational Test Before starting up the Soak Tank please clean all removable single parts as well as the unit itself with a fat loosening cleaning detergent very
2. e Use only cleaning and maintenance detergents which are completely harmless in connection with food even if there are very persistent dirt residues e After using of detergents all single parts have to be rinsed with clear water and rubbed dry with a towel All detergent residues have to be removed e is to observe the following principles in order to secure the life and durability of a stainless steel unit Keep the stainless steel surface clean Keep the stainless steel surface thoroughly ventilated Avoid any touch of the surface with rusty parts Note Do not use any bleaching or chlorine containing detergents In any case do 54 never use scouring or scraping cleaning detergents equipment for the pipe hea ter 5 1 2 Cleaning and Maintenance Detergents In order to guarantee a quick and easy cleaning we recommend our special cleaning and main tenance detergents being part of our product range e Grill detergent Apply the grill detergent evenly and let it soak for approximately 10 15 minutes Then rinse the part completely with water e Stainless Steel Maintenance Detergent Spray it on the surface with a distance of about 25 cm and then wipe it off with a smooth and dry towel If there are only small surfaces spray directly on a clean duster and wipe So you will achieve an easy cleaning with a gleaming result printed 09 2010 Subject to change lt RF8030UserManual doc Maintenance 5 2 Trouble Shooting If yo
3. thoroughly Note Do not use any inflammable liquids for the cleaning Do not clean the Soak Tank with a jet of water steamjet high pressure cleaner In the chapter Cleaning and Maintenance we will give you detailed instructions With this first basic cleaning the formation of smoke and smell will be minimized So you will work with this Soak Tank in a secure and hygienic manner 3 5 Starting Up e Place the unit at its position and fix the casters e Filla clean pail with approximately 10 liters of hot water e Stir the soda 4kg into the hot water until it is completely dissolved e Pour the suds into the unit Note The bowl faucet has to be closed e The unit has to be filled with water up to the MAX marking e Putin the plug e Switch on the unit the yellow control light on the main switch shows the operating condition of the Soak Tank e The lighting up of the yellow control light on the upper side of the switchbox shows the heating phase e f necessary fill in 1 cup of usual dishwasher detergent corresponds to detergent tabs printed 09 2010 Subject to change lt RF8030UserManual doc Operation 4 Operation As the soda mixture develops its optimal cleaning effect at about 85 C 185 F the control ther mostat is already fixed on this temperature by UBERT If the time of standstill of your RoFry should be often shortly we recommend to switch on the soak ing tank already 3 hours
4. 09 2010 Subject to change lt RF8030UserManual doc 15 Amount map Amount 1 gt RF8030UserManual doc 107920 107927 107928 338132 338133 340715 341108 341301 342211 342225 355313 355314 370108 381113 381119 107920 107927 107928 330401 338132 338133 340715 341136 342211 342225 355314 355315 370108 381113 381119 Maintenance 5 5 2 Spare Parts Lists RF8030 1 Description Access Plate Cover Inner Bottom Charge Strain Relief Counter Nut Strain Relief Control light yellow Main Switch 240V plug Thermostat Safety Temperature Limiter Heating Element 2000W 230V Bowl Faucet Handle Castor Wheel with fixing Support Castor Wheel RF8030 2 Description Access Plate Cover Inner Bottom Charge Field Wire 120V UL Strain Relief Counter Nut Strain Relief Control light yellow Main Switch 120V Thermostat Safety Temperature Limiter Bowl Faucet Heating Element 1900W 120V UL Handle Castor Wheel with fixing Support Castor Wheel printed 09 2010 Subject to change Maintenance Amount 1 gt RF8030UserManual doc 107920 107927 107928 330400 338132 338133 340715 34110
5. 8 342211 342225 355313 355314 370108 381113 381119 16 RF8030 208 Description Access Plate Cover Inner Bottom Charge Field Wire 250V UL Strain Relief Counter Nut Strain Relief Control light yellow Main Switch 240V Thermostat Safety Temperature Limiter Heating Element 2000W 230V Bowl Faucet Handle Castor Wheel with fixing Support Castor Wheel printed 09 2010 Subject to change
6. User Manual RoFry Soak Tank RF 8030 LOW FAT amp MORE TASTE BY UBERT Contents 3 1 Contents Lr 3 27 Important co dioe e Guten 4 2 7 4 E MEN 4 229 Dad oce e 4 24 Product 00900 4 3 4 Installation Sey 5 SO UADACKING nd esas Mu E 5 3 2 AIST ATION PU M 5 EE MEN Electrical Connection T E 5 34 First Op rati nal 6 A 8 8 EE E E E EA DP ESN eee are RC OE ee er 6 LEE ru 7 cinis TIT T 8 5 1 Cleaning and Upkeeping od eet UR tpe pde OR e RP ate le dene etur gus 8 52 SAO OUAG NM ES 9 53 WAG Diagram 120V toro ted d HDi tti tie 10 54 Wiring Diagram 200 240 11 5 5 Spare Parts oe ERE e aa ede due tg b elu ee m Ede pd e eee etx eee 12 printed 09 2010 Subject to change RF8030UserManual doc 4 Important References 2 Important References 2 1 General Before starting up your new Soak Tank you should read this operation manual thoroughly UBERT s machinery is manufactured with high quality materials and therefore meets an excellent quality standard 2 2 Dimensions 2 3 Technical Data Dimensions width x height x depth 455mm
7. before putting in the parts to be cleaned in order to preheat the soda mix ture on operation temperature Depending on the dirtiness of the parts the cleaning should be left in the liquid for 3 4 hours on operation temperature Please proceed the putting in as follows e Take the basket and the basket holder out of the RoFry put these down a convenient place and draw the basket out of the basket holder up to the end Take the airguiding metal and oil drawer out of the RoFry e Remove the knurled nut take it out as well as the fan wheel and put both parts into the basket now push the basket back into the basket holder e Take the drip bowl from the door and empty it e Always put firstly the basket and the basket holder into the soaking tank e Now you can put in all other parts e When you put out the cleaned parts please work reverse i e take the basket and the basket holder out of the soaking tank always last e Rinse all parts with clear water Note The soak tank is not convenient for the fresh air filter of the RoFry as this is made from aluminum printed 09 2010 Subject to change lt RF8030UserManual doc 5 Maintenance Following you will find some important notes concerning the maintenance eventually interference eliminations as well as a service case with your soaking tank 5 1 Cleaning and Upkeeping Note Before you start with cleaning the unit has to be disconnected M 5 1 1 General notes
8. o change lt RF8030UserManual doc Maintenance 11 5 4 Wiring Diagram 208 240V 230V 50Hz 2kW L1 A i T On Off Switch P i yellow Thermostat 185 F 0 High Limit witch 266 F Heating Element 230V 2KW 09 pilot light printed 09 2010 Subject to change lt RF8030UserManual doc 12 Maintenance 5 5 Spare Parts Note Defect parts are only to be replaced with original spare parts of the company 14 Ubert Gastrotechnik GmbH only service technicians of Ubert or service technician of your responsible service company are allowed to carry out replacements If you do not observe this note or in case of manipulation of a third party any claims for guarantee will become invalid 5 5 1 Explosion Drawings RF8030 1 107927 370108 107928 555313 581119 555514 381113 342210 342225 340715 338132 538153 341108 printed 09 2010 Subject to change lt RF8030UserManual doc Maintenance 13 RF8030 2 107927 5 0108 107928 399315 281119 555314 29 T1125 542210 542225 240715 3381352 2358133 041136 107920 n printed 09 2010 Subject to change RF8030UserManual doc 14 Maintenance RF8030 208 107927 5 0108 107928 5595313 581119 555314 581115 542210 542225 540715 200132 238135 941108 107920 530400 printed
9. ur Soak Tank does not work satisfactorily we would like to give a first help with the following checklist Only after checking these points you should contact a your responsible service partner or b directly the company UBERT GASTROTECHNIK GmbH Werk Il Gewerbegebiet Nord Vennekenweg 17 46348 Raesfeld Tel 49 02865 602 226 Service Tel 0172 2 82 86 31 Fax 49 02865 602 102 or 103 Note Only these two companies are allowed to carry out service work and replace ment of defect parts If you do observe this note in case of manipulation of a third party any claims for guarantee will become invalid 5 2 1 Malfunction Check List Interference Possible Cause Soaking Tank does not a Energy supply is not o k Check the plug work Control the automatic cut out b Fuses are defect Inform your local electrician Soak Tank does not heat Safety Temperature Limiter Let the unit cool down unscrew up has tripped the black protective cap at the front of the switch box push the reset button of the STL b Thermostat defect Inform the Service technician c Heating element defect Inform the Service technician printed 09 2010 Subject to change lt RF8030UserManual doc Maintenance 5 3 Wiring Diagram 120V 120V 60Hz 1 9kW N A PE On Off Switch Thermostat T 185 F High Limit beh 266 F Heating Element 120V 1 9kW pilot light printed 09 2010 Subject t
10. x 810mm x 530mm Weight 23 5 kg Power RF 8030 2 0 kW 230 V AC Power RF 8030 2 1 9 kW 120 V AC Noise emission lt 70 dB 2 4 Product Description The Soak Tank is an electrically heated tank with a thermostatically control and a safety tempera ture limiter high limit control It has a capacity of approximately 100 liters The unit is equipped with two casters which can be fixed in order to avoid an unintentional moving The cleaning mixture can be drained off by a bowl faucet at the bottom of the tank It is used for the cleaning of all removable parts of the RoFry except the fresh air filter printed 09 2010 Subject to change lt RF8030UserManual doc Installation and Starting Up 3 Installation and Starting Up In general the RoFry Soak Tank is secured for transportation after the final inspection so that it will reach the place of destination without any damage Nevertheless we recommend to check the unit for its good condition when it is unpacked Note Please inform us immediately about visible damages M 3 1 Unpacking Remove carefully the packaging and filling material from the RoFry Soak Tank to prepare it for the installation Take out all movable parts and check them for completeness Please learn the supply schedule from the delivery note 3 2 Installation During the installation of the Soak Tank please pay attention to the following points e The machine has to be lined up horizontally and vertically
Download Pdf Manuals