Baxi Combi 130 HE Owner's Manual
Contents
1. Ensure that the electricity and gas supplies are Domestic Hot Water turned on Control Button Reset Button 2 Remove the lower door panel Fig 1 Temperature F Central Heating i Control Buttons I Aessen F l Control Button 3 Press the Summer Winter mode button 842W Fig 2 until the required setting is shown on the Summer Winter Parodi oao Buto Control Panel Fig 2 indicates the summer setting and only hot water will be provided when a tap or shower is turned on indicates the winter setting and the central heating will operate on demand or the hot water will be provided when a tap or shower is turned on 4 Priority is given to domestic hot water The boiler control system has an automatic time delay built in for central heating It is normal that following a shutdown by the boiler thermostat timer or roomstat there is a delay of approximately 3 minutes before relighting 5 The boiler will light automatically on demand 6 The orange indicator on the badge will light when the boiler is operating and the main burner is on Fig 2 7 When there is no demand the boiler remains permanently in standby mode NOTE The boiler is still live The boiler can only be turned off by means of the isolation switch 3 1 0 Operating the Boiler GE Temperature Control Central Heating The boiler will automatically achieve the optimum flow temperature for maximum comfort a
2. Regulations The Building Regulations Scotland Building Regulations Northern Ireland The WATER FITTINGS REGULATIONS OR WATER ByeELaws in Scotland The current 1 E E WIRING REGULATIONS Where no specific instructions are given reference should be made to the relevant BRITISH STANDARD CODES OF PRACTICE Reference should also be made to BRITISH Gas GUIDANCE NoTEs FOR THE INSTALLATION OF Domestic Gas CONDENSING BOILERS In IE the installation must be carried out by a competent person and installed in accordance with the current edition of 1 S 813 Domestic Gas INSTALLATIONS The current BUILDING REGULATIONS Reference should also be made to the current ETCI rules for electrical installation 2 This appliance must be installed in accordance with the manufacturer s instructions and the rules in force and only used in a suitably ventilated location 3 Read the instructions before installing or using this appliance 4 Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction E Electricity Supply 1 THIS APPLIANCE MUST BE EARTHED 2 A standard 230V 50H supply is required The appliance must be protected by a 3 amp fuse STANDARD Domestic Gas Installations The following BS standards give valuable additional information B S 5546 Installation of hot water supplies for domestic purposes B S 7074 Expansion vessels and ancillary equip
3. during the guarantee period as a result of faulty workmanship or material whilst in normal use will be repaired or replaced free of charge Eo Servicing your Appliance 1 For reasons of safety and economy your boiler should be serviced annually Servicing must be performed by a competent person see Definition of competence page 9 5mm Min 490mm 5mm Min e N 200mm y E i 850mm y A 200mm f y Fig 8 For Servicing Purposes lt lt 320mm gt 5mm Fig 9 In Operation 1 in 20 3 0 Clearances ERM Clearances around the Boiler Figs 8 amp 9 1 The minimum clear spaces needed around the boiler measured from the casing are as follows Top 5 200mm Bottom 200mm Both sides 5mm Front 500mm For Servicing 5mm In Operation 2 These areas must not be obstructed in any way Blocking the clearance spaces may result in the boiler overheating and damage may occur 3 The gas burning compartment of your boiler is completely sealed from the room in which it is fitted Products from the combustion of gas are vented to the outside through the flue terminal which must be kept free from obstruction as this would interfere with the correct operation of the boiler 4 Where the appliance is installed in a cupboard or compartment no air vents are required The label affixed to the front of the boiler must not be removed The information will be
4. orange Burner Central Heating ON indicator Control Button _ summer Winter Mode Button Temperature Control Buttons Reset Button EEJ Resetting the Appliance 1 The appliance only needs resetting if the red flame failure light is on Fig 3 Fig 4 2 If the red flame failure light is on press the Reset button Reset Fig 4 until the red flame failure light goes off Control Panel 3 If this occurs persistently consult a competent person see Definition of competence page 9 2 0 Care of the Boiler ES Central Heating System Pressure 1 The water pressure in the central heating system is indicated by the pressure gauge 2 The normal operating pressure is in the range between 1 and 2 5 bar Fig 5 3 A pressure of 3 bar or greater indicates a fault Fig 6 The safety pressure relief valve will operate at a pressure of 3 bar It is important that a Competent Person see Definition of competence page 9 is contacted as soon as possible Lower Door Panel 4 The MINIMUM pressure for correct operation is 1 bar If the pressure falls below this it may indicate a leak on the central heating system Fig 7 5 The system must be re pressurised by a Competent Person see Definition of competence ieeeute Gauge page 9 BB Frost Protection 1 If a frost thermostat has been fitted or the system frost protection has been enabled then to op
5. required by service engineers in the future The compartment should be large enough to house the boiler and ancillary equipment only 5 IT SHOULD NOT BE USED AS A STORAGE CUPBOARD 4 0 Check List Emergency CAN Check List 1 If a fault develops or is suspected a Competent Person see Definition of competence page 9 as soon as possible 2 Go through the following check list before you make contact a Is the electricity supply on b Is the boiler set for both Central Heating and Domestic Hot Water Showing On c Is the red Flame Failure indicator illuminated if so press the Reset Button d Is the gas supply on e Is the mains water supply turned on f Are the boiler temperature controls set high enough g Is the time clock if fitted calling for central heating h Is the room thermostat if fitted set high enough i Are the radiator valves open LJ IN AN EMERGENCY If a water or gas leak occurs or is suspected the boiler can be isolated at the inlet valves as follows 1 Turn off the electrical supply 2 The isolating valves are positioned under the boiler and can be closed using either a flat headed screwdriver or a 7mm open ended spanner across the flats 3 Turn the gas tap clockwise to the stop position to isolate the gas supply at the boiler 4 To isolate the water system close the four valves fully by turning clockwise 5 Call a Competent Person see
6. BAXI User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe Should you move house please hand them over to the next occupier Natural Gas Baxi Combi 130 HE G C N 47 075 04 Baxi is one of the leading manufacturers of domestic heating products in the UK Our first priority is to give a high quality service to our customers Quality is designed into every Baxi product products which fulfil the demands and needs of customers offering choice efficiency and reliability To keep ahead of changing trends we have made a commitment to develop new ideas using the latest technology with the aim of continuing to make the products that customers want to buy Everyone who works at Baxi has a commitment to quality because we know that satisfied customers mean continued success We hope you get a satisfactory service from Baxi If not please let us know FOS WRAS 3 Apes pro RECOMMENDED nN benchmark Baxi is a BS EN ISO 9001 Accredited Company The boiler meets the requirements of Statutory Instrument The Boiler Efficiency Regulations 1993 N 3083 and is deemed to meet the requirements of Directive 92 42 EEC on the energy efficiency requirements for new hot water boilers fired with liquid or gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0086 Product
7. Definition of competence page 9 as soon as possible IMPORTANT Installation Commissioning Service amp Repair This appliance must be installed in accordance with the manufacturer s instructions and the regulations in force Read the instructions fully before installing or using the appliance In GB this must be carried out by a competent person as stated in the Gas Safety Installation amp Use Regulations Definition of competence A person who works for a CORGI registered company and holding current certificates in the relevant ACS modules or valid ACoP equivalents is deemed competent In IE this must be carried out by a competent person as stated in S 813 Domestic Gas Installations Lifting This product should be lifted and handled by two people Stooping should be avoided and protective equipment worn where necessary Carrying amp lifting equipment should be used as required The addition of anything that may interfere with the normal operation of the appliance without express written permission from the manufacturer or his agent could invalidate the appliance warranty In GB this could also infringe the Gas Safety Installation and Use Regulations Warning Check the information on the data plate is compatible with local supply conditions Benchmark Installation Commissioning and Service Record Log Book Please ensure that your installer has completed the Installation and Commissioning sec
8. Production certified by Notified Body 0086 Ref 86 BL 647 For GB IE only 1 0 Operating the Boiler ERN Introduction 1 Your Baxi Combi 130 HE is a gas fired room sealed powered flue condensing combination boiler providing central heating for your home and mains fed domestic hot water It is fully automatic and does not have a pilot light Frost and pump protection are an integral part of the appliance 2 Priority is given to the hot water mode when a hot water tap is turned on the supply of heat to the Lower Door Panel R central heating circuit is interrupted 3 Intelligent Pre Heat The boiler incorporates an intelligent pre heat feature This ensures that the domestic hot water to the tap is pre heated only when the user required hot water the previous week The pre heat switches the boiler on for Fig 1 approximately 1 minute every 40 minutes when required This function can be switched off if not Burner ON Indicator Flame Failure Indicator required During the first week of operation from Orange Light Red Light q g P n power on no pre heating will occur pO oO 3 A shortened version of these operating Pressure Gauge instructions appears on the reverse of the lower LCD Display door panel A label gives details of the model serial number G C N and the manufacturer s name and address EEJ Operating the Boiler 1
9. erate correctly and protect your system the gas and electricity must be left on and the appliance set in the winter mode see section 1 2 Fig 5 Normal Pressure BEBE Cleaning the Outercase The painted panels should be wiped with a damp cloth and then dried completely DO NOT USE ABRASIVE CLEANING AGENTS BAXI EZE Spare Parts Fig 6 1 Any repairs to the boiler will usually be the Fault responsibility of the Installer during the guarantee period after which spare parts may be obtained through approved Baxi stockists if required 2 Quote the appliance name model number and where possible the part number when ordering spares A short parts list is included in the ON Installation and Servicing Instructions BAXI Never Hang Any Items Over The Appliance Fig 7 Below Minimum 2 0 Care of the Boiler BJ Guarantee 1 Your Baxi Combi 130 HE is designed and produced to meet all the relevant Standards 2 Baxi provide a 12 month guarantee on the boiler The guarantee operates from the date installation is completed for the customer who is the original user 3 To maximise the benefit from our guarantee we urge you to return the reply paid guarantee registration 4 This does not in any way prejudice your rights at Common Law Such rights between the customer and the installer or supplier from whom the unit was purchased remain intact Any component or part which becomes defective
10. ment for sealed water systems Forced circulation hot water systems Treatment of water in domestic hot water central heating systems 6 0 Notes Baxi manufacture a comprehensive range of products for the domestic heating market Gas Central Heating Boilers Wall Floor and Fireside models Independent Gas Fires Renewal Firefronts Gas Wall Heaters Solid Fuel Fires If you require information on any of these products please write telephone or fax to the Sales Department 11 BAXI POTTERTON A Trading Division of Baxi Heating UK Ltd Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN After Sales Service 08706 096 096 Technical Enquiries 08706 049 049 Website www baxi co uk A BAXI GR UP company When contacting Baxi Potterton please have the following information to hand Appliance Name Model Number Serial Number A label giving these details is situated on the rear of the lower door panel attached to the users operating instruction label Users Operating Instruction Label Lower Door Panel Comp N 245737 Iss 02 11 03
11. nd efficiency 1 However in the case of the elderly infirm or very young a lower radiator surface temperature may be desirable If so the central heating flow temperature can be adjusted between 45 C 3 C minimum and 82 C 5 C maximum Lower Door Panel 2 To set the required temperature press and hold the Central Heating Control Button T whilst adjusting the necessary Temperature Control Button Fig 4 Domestic Hot Water The boiler will automatically achieve the optimum flow Burner ON Indicator i Flame Failure Indicator temperature for maximum comfort and efficiency Orange Light Red Light k i 7 1 The temperature of the domestic hot water can 2 JO be adjusted between 35 C 5 C minimum and Pressure Gauge 55 C 5 C maximum 2 To set the required temperature press and hold the Domestic Hot Water Control Button F8 whilst adjusting the necessary Temperature Control Button Fig 4 3 Ata DHW temperature set point of 45 C the flow rate can be reduced down to as low as 3 5 litres min without any degradation of the hot water control No DHW will be provided at less than 3 5 a a litres min Fig 3 p NOTE Two status indicators can be seen through the badge Fig 3 The right hand symbol is the red Flame Failure indicator Domestic Hot Water Control Button The left hand symbol is the
12. tions of the Log Book and hands the Log Book over The details of the Log Book will be required in the event of any warranty work Keep the Log Book in a safe place and ensure that the relevant sections are completed at each subsequent regular service visit All CORGI registered installers carry a CORGI identification card and have a registration number Both should be recorded in your boiler Log Book You can check your installer is registered by telephoning 44 0 1256 372300 or writing to 1 Elmwood Chineham Business Park Crockford Lane Basingstoke RG24 8WG In GB the following Codes of Practice apply In IE STANDARD B S 6891 Gas Installation B S 5440 Pt 1 B S 5546 Installation of hot water supplies for domestic purposes B S 7074 Expansion vessels and ancillary equipment for sealed water systems Forced circulation hot water systems Installation of gas fired hot water boilers Treatment of water in domestic hot water central heating systems 798 B S 5793 13 B S 5449 5 0 Legislation E Safe Installation 1 The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force In GB the installation must be carried out by a CORGI Registered Installer It must be carried out in accordance with the relevant requirements of The Gas Sarety Installation and Use REGULATIONS The appropriate BulLDING REGULATIONS either the Building