Home
Avaya P117F(R) Installation Manual
Contents
1. gt gt gt PRESS Enter to continue You will need to reset the unit in order to implement the change 32 P117F R Stackable Switch Installation Guide Chapter 3 Configuration 10 7 ILMI ATM Address This option allows you to define how the ATM address prefix will be allocated to the P117F R unit To access the ATM address prefix menu select ATM Address ILMI ATM address menu Visage 16155 R S W Version Slot 4 CR Refresh the screen 0 Return to Previous Menu 1 Display current ATM address prefix 2 Display configured ATM address ILMI 3 Display default ATM address ILMI 4 Change configured ATM address ILMI gt gt gt Enter your choice Changing configured ATM address ILMI 1 Tochange the configured ATM address prefix select Change configured ATM address ILMI You can define the ATM address in two ways either e Type 0 for the P117F R to use the ILMI protocol to obtain the 13 byte ATM prefix from the ATM switch or Enter 19 bytes manually the 13 byte ATM prefix and the 6 byte ATM ESI The manual option is intended for switches that do not support the ILMI protocol Current ATM address prefix 39 00 00 00 00 00 00 00 00 6 07 c0 cb Configured ATM address using ILMI Default ATM address using ILMI gt gt gt Enter ATM address xx xx 19 bytes 0 for using ILMI 39 00 00 00 00 00 00 00 00 5a 07 cf cb gt gt gt PRESS Enter to continue
2. 2 Press Enter to return to the ATM address prefix menu 3 Reset the module for the changes to take effect press 0 to return to Main Menu and then 1 to Reset P117F R Stackable Switch Installation Guide 33 Chapter 3 Configuration 11 8 LECS ATM Address This option allows you to change using the following algorithm 1 Address entered by the user the LECS ATM address This address is derived 2 ILMI if the user has not entered a value 3 Well known address WKA 4 VPOVC17 It is therefore not necessary to To access the LECS ATM address LECS ATM Visage 16155 R S W Ve lt CR gt Refresh the screen Return to Previous Menu Display LECS ATM address Display configured LECS ATM address Display Default LECS ATM address Change configured LECS ATM address Enter your choice Changing the Configured LECS ATM enter the well known address in this screen menu select the LECS ATM address option address menu rsion Slot d address 1 Tochange the configured LECS ATM address select Change configured LECS ATM address LECS ATM address 47 00 79 00 00 a0 3e 00 00 01 00 Configured LECS ATM address us Default LECS ATM address us gt gt gt Enter LECS ATM address xx xx gt gt gt PRESS Enter to continue 34 00 00 00 00 00 00 00 00 00 ing ILMI WKA PVC ing ILMI WKA PVC 20 bytes 0 for using ILMI WKA PVC P117F R Stackable Switch
3. This option returns Ethernet port parameters such as VLAN number and enable status to their default values It does not affect agent access parameters such as IP addresses IP Routes and Permanent Managers It does not set the ATM port parameters to their default values Use this option if for example in using device management you accidentally disabled the port to which the management station is connected If you disable the Ethernet port to which the management station is connected you will no longer be able to contact the P117F R from the device manager Enter your choice WARNING Port parameters were changed Reset the agent Enter to continue P117F R Stackable Switch Installation Guide 39 Chapter 3 Configuration 40 P117F R Stackable Switch Installation Guide Chapter 4 Terminal Connector Pin Assignments Figure 6 Terminal port RS 232 Wiring Connection to Console Terminal RJ45 1 E Ps 2 Rx gt P 3 h TX 4 ES M 5 Ground 6 7 i P P117F R Stackable Switch Installation Guide 41 2003 Avaya Inc All rights reserved All trademarks identified by the or TM are registered trademarks or trademarks respectively of Avaya Inc All other trademarks are the property of their respective owners Document number 130001 Rev A
4. 27 Chapter 3 Configuration 1 Select Update to change the community Trap Community Menu Visage 16155 R S W Version lt CR gt Refresh the screen Return to Previous Menu Save the Session Update Enter your choice 2 Trap Community name is public gt gt gt Enter Trap Community name 24 char hardware alpha 2 Enter the community name or Enter to leave it unchanged 3 Select 0 Return to Previous Menu to return to the previous menu without saving the changes 4 Select 1 Save the Session to save the changes then 0 Return to Previous Menu to return to the previous menu A similar procedure is used to change the Read Only and Read Write communities 28 P117F R Stackable Switch Installation Guide Chapter 3 Configuration 6 Permanent Managers Not applicable for P117F R Stackable Switch in a stack This option allows you to define up to ten management stations which can receive gt gt gt PO ON HD Ul P t NN FP 0 gt gt gt alarms Permanent Managers Menu Visage 16155 R S W Version lt CR gt Refresh the screen Return to Previous Menu Save the Session List Add Delete Update Enter your choice Listing Permanent Managers 1 To list permanent managers select List Permanent Managers 149 49 42 90 oo o oooooooo oooooooo oooooooo 0 0 0 0 Enter CR to continue Slot 2 Press Enter to r
5. gt gt gt Enter gt gt gt Enter 26 32 74 12 149 43 63 123 32 74 53 149 43 69 1 000 000 000 149 43 63 123 000 000 000 000 000 000 000 000 000 000 000 000 000 000 route destination address nnn nnn nnn nnn 150 61 23 18 route gateway IP address nnn nnn nnn nnn 135 49 50 1 Type the Gateway IP address address of the router and press Enter To review your changes select the List command To save your changes select Save the Session Type 0 to return to the Setup main menu Changes to IP Routes do not require you to reset the agent NS STE P117F R Stackable Switch Installation Guide Chapter 3 Configuration 5 SNMP Community Not applicable for P117F R Stackable Switch in a stack This parameter defines the trap read only and read write communities The community name can be up to 24 characters in length The default community for all three options is public SNMP Community Menu Visage 16155 R S W Version CR Refresh the screen 0 Return to Previous Menu 1 Trap Community 2 Read Only Community 3 Read Write Community gt gt gt Enter your choice Slot Select Trap Community to change the Trap community the SNMP community to which traps are sent Trap Community Menu Visage 16155 R S W Version CR Refresh the screen 0 Return to Previous Menu 1 Save the Session 2 Update P117F R Stackable Switch Installation Guide Slot
6. Bits 8 Stop Bit 1 Parity none Refer to your console terminal s user manual for instructions on how to set these parameters 2 Insert the RJ 45 cable into the Console port of the P117F R cable pinouts can be found in the Appendix to this guide 3 Insert the other end of the cable into the terminal s RS 232 port 4 Press Enter to verify that the cabling process was successful P117F R Stackable Switch Installation Guide 13 Chapter 3 Configuration Software Download Summary Below is a procedure checklist for successfully configuring a P117F R for SNMP management Instructions for each item in the list can be found in the pertinent sections of this guide Y If necessary enter an IP address for the P117F R and reset the switch Y If you re using routers set up a default gateway Y Perform software download Y Set SNMP Community Setup Menus Setup Main Menu A series of menus guides you through the configuration process After the switch enters setup mode the first screen of the setup session is automatically displayed It shows the current configuration of the agent Underlined spaces in the example screens represent variables Description of Agent Parameters S W Version Slot d HUB Type Cajun P110 Trap Community Name Read Write Communities Wy 4 Interfaces Physical Address IP Address Netmask InBand Interface 00 40 0d 00 00 05 000 000 000 000 000 000 000 000 0x00000000 E
7. latest available software The P110 on board agent software is stored in flash memory and can be upgraded via software download using the TFTP protocol In the P110 on board agent the flash memory contains two independent software versions the Basic and the Application version The Application version is the one that the P117F R will use in normal operation If the Application version is found to be faulty the Basic version will be used instead if a failure occurs during download Caution Download the Basic version only when the new Application version is working correctly This will ensure that if there is a problem with the application version the agent will be able to switch to a valid Basic version 18 P117F R Stackable Switch Installation Guide Chapter 3 Configuration The TFTP Process The agent software file should be placed on a computer that can be located anywhere on the network During the TFTP process the computer acts as the Server and the agent as the Client From the Terminal the user configures the agent with the IP address of the TFTP server the file name to be downloaded and the download destination bank The Agent then gets the specified file from the server During the download process the user can monitor the process status parameters by using the Monitor Software Download Process sub menu The agent remains fully functional during the download process At the end of a successful download the whole sta
8. of the front panel P117F R Stackable Switch Installation Guide 9 Chapter 2 Installation Diagnostics Tables 2 and 3 explain the meaning of the P117F diagnostic LED indicators Figure 4 The P117F Front Panel LEDs and Buttons O O O O 6 9 PWR NMA RED OPR LNK COL Tx Rx FDX O0 OO 0 000 0 NMA Figure 5 The P117FR Front Panel LEDs and Buttons O PWR NMA RED OPR LNK COL Tx Rx FDX O O O 000008 NMA 10 P117F R Stackable Switch Installation Guide Chapter 2 Installation Table 2 Meaning of the P117F Front Panel Buttons Button Function Meaning o O Select The buttons determine what function will be displayed by the 17 Port LEDs the top two rows of LEDs The five Function LEDs above the Select buttons show which function is currently displayed by the Port LEDs The Port LEDs can display either Link Collision Transmit Receive or Full Duplex If for example the Link LNK LED is lit then LEDs 1 to 17 will display the Link status of every port For P117FR ATM port LEDs see also Table 4 Press left or right button to toggle the Port LED display between functio Reset Press and hold both buttons simultaneously for two seconds to reset the entire P110 stack In a Reset all LED indicators turn on Pressing Reset does not affect configuration settings Table 3 Meaning of the P117F R Stackable Switch front panel LEDs LED Indicator Power Mains power not connected Mains power connec
9. 17FR jointly referred to as the P117F R e Installation Instructions for getting the P117F R Stackable Switch and P110 stack up and running e Software Download Step by step guide to downloading a new software version to the P117F R Stackable Switch on board agent e Appendix Pin Assignments for the console RJ45 connector Description The P117F R is part of the P110 Switching System family of switches The P110 family is composed of high performance switches which may be used singly or stacked in any combination to make up a multi protocol non blocking scalable switch The P117F has 16 Ethernet 10BASE T ports and one 155 Mbps ATM port The P117FR has an additional ATM port for redundancy The 10 Mbps ports are typically used for workgroup connectivity while the ATM port s can be used as an uplink to an ATM backbone The P117F R can operate standalone or as part of a stack A stack can be made up of any combination of two three or four P110 switches and up to 32 000 MAC addresses per stack are supported A stack requires a P110 NMA to link the switches The units are physically linked using the P110 Exoplane which makes up a multi gigabit non blocking backplane The P117F R can use Avaya automatic fairness mechanism on the Ethernet ports to ensure that all ports gain fair access to the P110 Exoplane even at very high network utilization Congestion management works both on full and half duplex ports and ensures no pack
10. Denotes a sequence number To select an item from any menu etc type its sequence number e Setup sub menus display the following standard functions This function Return to Go back one menu level Previous Menu List the current values for the selected parameter Save the Save and store changes to the selected parameter and activate Session changes When saving the session the changes become active no need for reset and stored in the non volatile memory Reset the This is needed when assigning an IP address and ATM Agent parameters to the Agent In other cases the Agent will activate new parameter values when the user chooses the Save the Session option e If you forget to save changes or reset the agent when necessary the following warnings will remind you to do so before exiting the relevant sub menu of the Setup session This WARNING No save since last Type lt y gt to save parameter changes If you change Save y n type n all changes will be lost IP address was changed Agent must be reset in order to activate IP Reset the agent changes Reset may be done after each change or at the end of the entire Setup session P117F R Stackable Switch Installation Guide Chapter 3 Configuration Parameter configuration The following sections provide step by step instructions for configuring each parameter In many module configuration menus the following parameters are displayed e D
11. Installation Guide Chapter 3 Configuration 2 Enter the new address and press Enter If you enter 0 as the new address the procedure will use the ILMI WKA or PVC in that order as explained at the top of the page 3 Press Enter to return to the LECS ATM address menu 4 Reset the module for the changes to take effect press 0 to return to Main Menu and then 1 to Reset Enter a specific address only for an ATM switch that does not support ILMI protocol or P V C s and its LECS address is not Well Known Address WKA 12 9 ELAN Configuration This option allows you to display ELAN VLAN associations and display and change the default ELAN name To access the ELAN configuration menu select ELAN configuration ELAN Configuration menu Visage 16155 R S W Version Slot 4 CR Refresh the screen 0 Return to Previous Menu 1 Display ELAN VLAN associations 2 Display default ELAN information 3 Change default ELAN name gt gt gt Enter your choice P117F R Stackable Switch Installation Guide 35 Chapter 3 Configuration Display ELAN VLAN associations 1 To view current ELAN VLAN assocations select Display ELAN VLAN associations An example is shown here ELAN VLAN Associations Assoc LecIF Status Status IfIndex Active Active Active Active Active Active Active 1 0 2 1 4 3 5 4 6 5 7 6 8 7 9 8 0 9 nd Active gt gt gt Press Enter to contin
12. Installation Guide P117F R STACKABLE ETHERNET SWITCH WITH ATM UPLINK AVAVA Important Information SAFETY PRECAUTIONS CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK AND FIRE 1 e All servicing should be undertaken ONLY by qualified personnel The parts inside the unit CANNOT be serviced or repaired by the end user Please call your service representative for assistance Do NOT plug in turn on or attempt to operate a damaged unit Ensure that the chassis ventilation slots in the unit are NOT BLOCKED Replace a blown fuse only with the same type and rating as is marked on the safety label adjacent to the power inlet housing the fuse DO NOT operate the unit in a location where the maximum ambient temperature exceeds 50 C Be sure to unplug the power supply cord from the wall socket BEFORE attempting to remove and or check the main power fuse PRECAUTIONS DE SECURIT AVERTISSEMENT POUR R DUIRE LE RISQUE DE CHOC LECTRIQUE ET D INCENDIE 1 2 3 Tout entretien doit tre fait UNIQUEMENT par un personnel de service qualifi Aucun l ment ne peut tre r par par un particulier NE PAS brancher allumer ou essayer de faire fonctionner une unit sur laquelle un doute existe quant son bon fonctionnement S assurer que les ouvertures d a ration du ch ssis dans l appareil NE SONT PAS OBSTRUEES Remplacer un fusible d faillant UNIQUEMENT par un mod le du m me type suivant les recommandations ind
13. NIX or MSNM or CajunView Manager on Windows or see the setup main menu of the P110 NMA 1 Turn off the main power to the stack by individually switching off each switch 2 Placethe P110 NMA in the top switch of the stack if it is not already there 3 Ifthe P110 NMA and P117F R on board agent contain the latest software version go to step 4 If the P110 NMA does not contain the latest software version you have to perform software download of the latest version The software is on the diskette that came with the P117F R Download is performed via the Software Update Manager in MSNM or in CajunView or via TFTP using a terminal details can be found in the P110 NMA Installation Guide The download procedure itself is the same as that described in Software Download on page 18 of this document If the P117F R on board agent does not contain the latest version perform the download as described in Software Download to the On Board Agent on page 13 6 P117F R Stackable Switch Installation Guide Chapter 2 Installation 4 Place the P117F R or other P110 switches in the stack The P110 NMA must be in the top switch of the stack To ensure proper ventilation ensure that all empty P110 NMA slots in the stack are closed 5 Connect P110 switches using the supplied P110 Exoplane cables as shown in Figure 2 A switch connects to its upper neighbor through two Exoplane cables and to its lower neighbor through another two Exoplane cab
14. Press Enter to return to the ELAN configuration menu P117F R Stackable Switch Installation Guide 37 Chapter3 Configuration 13 10 ATM Redundancy This menu only appears for the P117FR which has a redundant ATM port This menu enables and disables the redundancy mechanism Redundancy can be Enabled or Disabled and the Active port can be either the Upper or the Lower port ATM Redundancy menu S W Version CR Refresh the screen Return to Previous Menu Display Current redundancy parameters Display Default redundancy parameters Change redundancy mode Enter your choice e To display Current Redundancy Parameters select 1 e To display Default redundancy parameters select 2 e To set redundancy parameters to their default values select 3 You must Reset the module after changing to the default values e To change redundancy mode select 4 38 P117F R Stackable Switch Installation Guide Chapter 3 Configuration 14 11 Set ATM Port Parameters to their Default Values This option returns the ATM port parameters to their default values ATM port default values UNI Version a al Physical Media SONET ATM Address Using ILMI LECS ATM Address Using ILMI WKA PVC ELAN Configuration default ELAN Default Redundancy Mode ENABLE Default Active ATM Port UPPER Set ATM port to default values 15 12 Set Ethernet Port Parameters to their default values
15. When you receive the P117F R its on board agent comes pre loaded with fully functional software New software is made available at regular intervals You should make sure that all P110 units contain the latest available software Software download to the P117F R is performed via a console terminal connected to the serial port on the rear panel of the P117F R or via SNMP using a CajunView or MSNM network management station Instructions can be found in the appropriate documentation The following sections explain how to download software to the P117F R via a console terminal When working in a stack 2 3 or 4 P110 switches a P110 NMA should be inserted into the topmost switch of the stack and the appropriate software version downloaded separately to it The software is on the diskette that came with the P117F R For instructions on how to download software to the P110 NMA see the P110 NMA Installation Guide the download procedure itself is the same as that described below You must first update the P110 NMA before you add the P117F R to the stack Connecting the Console Terminal Software download to a P117F R Stackable Switch can be performed via a console terminal connected to the serial port labeled Console on the P117F R To connect the P117F R to a console terminal 1 Turn on the VT52 or VT100 terminal or PC in terminal emulator mode and set its communication parameters to Baud Rate 9600 bps Start Bit 1 Data
16. ck resets automatically Software Download Procedure Before starting the download procedure do the following 1 Ensure that the supplied agent software file resides on a computer with TFTP server capabilities 2 Ensure that the file is accessible to the agent Contact the agent from the TFTP server by typing ping ip address of agent Download software to the agent as follows 1 Select Software Download from the Setup Main Menu This opens the Software Download menu shown below Software Download Menu Using TFTP IP Visage 16155 R S W Version Slot 4 CR Refresh the screen Return to Previous Menu Save the Session TFTP Server and File parameters Start Software Download process Monitor Software Download process Enter your choice 2 Select TFTP Server and File parameters from the Software Download menu This opens the menu shown below P117F R Stackable Switch Installation Guide 19 Chapter 3 Configuration TFTP Server IP address 000 000 000 000 File Name Destination Flash B Application gt gt gt Enter Server IP address 000 000 000 000 135 49 60 115 gt gt gt Enter File Name home v16155 gt gt gt Enter Destination 1 Flash A Basic 2 Flash B Application 2 3 Type the IP address of the TFTP server and press Enter 4 Type the full Path and File Name v16155 of the agent software and press Enter 5 Type the destination memory location of the so
17. et loss should the buffers become saturated during peak load conditions A backup power supply P110 BUPS can be used for increased fault tolerance P110 switches are fully manageable using MSNM the Avaya SNMP based management system or CajunView and may be monitored using the SMON Manager Switch Monitoring Application P117F R Stackable Switch Installation Guide 3 Chapter 1 Description 4 P117F R Stackable Switch Installation Guide Chapter 2 Installation setting the DIP switches First set the DIP switches The position of the switches depends on the application The drawing below shows the default positions of the DIP switches on the rear panel of the P110 switch Figure 1 The P117F R Stackable Switch Rear Panel Showing the DIP Switches in their Default Positions m HOLIMS 3SN r um SNC Cy Cy e LSV Last SW Version The on board agent of the P117F R can use either the latest downloaded software or a Basic version The Basic version is factory loaded Ensure the Use Switch is set to the OFF position Once you have set the DIP switch you may proceed with the physical installation of the switch Table 1 DIP Switches on the P117F R Stackable Switch Function OFF ON Default Last SW Version Use the Basic Use the latest software downloaded version This is agent software kn
18. eturn to the Permanent Managers Menu P117F R Stackable Switch Installation Guide 29 Chapter 3 30 Configuration Adding Permanent Managers 1 2 To add permanent managers select Add Type in the IP address of the permanent manager and press Enter Deleting Permanent Managers 1 2 Select Delete from the Permanent Managers Menu Select the index number 1 10 of the permanent manager you wish to delete and press Enter Updating Permanent Managers 1 2 Select Update from the Permanent Managers Menu Select the index number 1 10 of the permanent manager you wish to update and press Enter Enter the new IP address and press Enter Press Enter to return to the Permanent Managers Menu P117F R Stackable Switch Installation Guide Chapter 3 Configuration 7 Module Advanced Configuration Not applicable for P117F R Stackable Switch in a stack This option is not currently implemented 8 5 UNI Version This option determines the UNI version used for the P117F R Before changing the UNI Version check that the ATM switch supports this version To display or update the UNI version select UNI Version UNI version menu Visage 16155 R S W Version Slot lt CR gt Refresh the screen 0 Return to Previous Menu 1 Display current UNI version 2 Display configured UNI version 3 Display default UNI version 4 Change configured UNI version gt gt gt Enter your choice Changi
19. etwork To assign an IP address and or Netmask 1 Select Agent Access Addresses from the Setup Main Menu This opens the sub menu shown below Agent Access Addresses Visage 16155 R S W Version Slot 4 CR Refresh the screen 0 Return to Previous Menu Save the Session Interfaces IP Address Netmask 2 InBand Interface 149 049 150 101 255 255 255 000 Oxffffff00 gt gt gt Enter your choice 2 Select InBand Interface The following prompt line displays InBand Interface IP address 149 049 150 101 netmask 255 255 255 0 gt gt gt Enter InBand Interface IP address 149 49 150 101 149 49 39 85 gt gt gt Enter InBand Interface netmask 255 255 255 0 255 255 0 0 22 P117F R Stackable Switch Installation Guide Chapter 3 Configuration 3 Type the new IP address as shown in the example above and press Enter Leading zeroes may be omitted 4 After the IP address is accepted the Netmask prompt is automatically displayed The prompt has a default value based on the IP address 5 Type the new Netmask value in the correct format or press Enter to accept the default value 6 Type 0 to return to the main menu Changes to IP Addresses and Netmasks require you to reset the agent You may reset the agent now or at the end of the entire Setup session P117F R Stackable Switch Installation Guide 23 Chapter 3 Configuration 4 IP Routes 24 When the P117F R is in stand alone conf
20. ftware The Application version is stored in Flash memory bank B and the Basic version is stored in memory bank A If you wish to download a new Application version type 2 Flash B as the destination and press Enter Caution Do not download the Basic version until the Application version is working correctly 6 Select Save the Session 7 Select Start Software Download process You will get a warning and a confirmation prompt as follows 8 Select y 9 Keep track of the progress of the software download by selecting Monitor Software Download process Press Enter to get an update of the download process 20 P117F R Stackable Switch Installation Guide Chapter 3 Configuration Agent Software Download Monitoring Screen Visage 16155 R S W Version Slot 4 TFTP Server 135 49 60 115 File Name c home v16155 Destination Flash Bank B Application Download State tftp running ip Activity Status Download Process Started Download Size CR Refresh the screen 0 Return to previous menu gt gt gt Enter your choice 10 The P110 will now automatically Reset itself Troubleshooting Software Download The following are Activity Status messages that can appear during software download their meanings and what you should do about them Activity Status Description Suggested action message file format Ensure that the correct agent unknown software file is being downloaded to the agent fi
21. he packet will not be sent If an agent or P110 stack does not appear on a management station as expected it may be as a result of the agent not including this station in its IP Route table Ping the agent to see if the agent is active The agent and stack may be operating normally even though the management station is not communicating with the agent To define an IP route you must supply e The IP address of the station or the network not subnet e The IP address of the gateway router P117F R Stackable Switch Installation Guide Chapter 3 Configuration To define an IP Route 1 Select IP Routes from the Setup Main Menu This opens the IP Routes sub menu shown below IP Routes menu Visage 16155 R S W Version Refresh the screen Return to previous menu Save the Session List static routing table Delete gt gt gt Enter your choice 2 Select Add to define a new IP Route Select Delete to remove an existing IP Route P117F R Stackable Switch Installation Guide 25 Chapter 3 Configuration 3 Type the destination address of a host IP address of the management station or a network IP of management network as shown in the menu below and press Enter For a default gateway leave the destination address as 000 000 000 000 IP Route parameters menu Visage 16155 R S W Version Slot 4 Refresh the screen return to the previous menu Destination Gateway 154 154 000 10 000 11 000
22. iguration and is connected to one side of a router on one network and the file containing the new software is located on the other side of the router on a different network you must set up a communication path via the IP Routes parameter An IP Route determines which gateway i e router will be used to communicate with the P117F R Whenever the agent sends a packet to a management station that does not reside on the same network the agent searches an internal table to determine via which router the packet should travel Part of this internal table is built from the data you enter for the IP Routes parameter The IP Routes parameter correlates host or network destination addresses of management stations with gateway addresses You may define multiple IP Routes from the agent to the management station As the agent searches the IP Routes table it will select the gateway that was added last If that gateway is unavailable it will proceed to the gateway added before the last one and so on You may also define a default gateway for all management stations rather than define a specific gateway for each possible destination If the agent cannot find a particular network or host destination address in its IP Routes table it will use the default gateway the default gateway is correlated with destination address 000 000 000 000 If the agent cannot find a particular network or host destination address and no default gateway has been defined t
23. iqu es sur l tiquette de securit pos e dans le logement du fusible NE PAS faire fonctionner l appareil dans un endroit o la temperature d passe les 50 C S assurer de d brancher l alimentation lectrique AVANT toute manipulation sur le fusible principal SICHERHEITSVORKEHRUNG ACHTUNG ZUR VERHINDERUNG DES RISIKOS VON ELEKTRISCHEM SCHLAG UND FEUER 1 P117F R Stackable Switch Installation Guide Die Ger te enthalten keine Bauteile die au erhalb des Avaya Servicezentrums gewartet oder repariert werden k nnen Die Wartung darf NUR von qualifiziertem technischem Personal durchgef hrt werden NIEMALS ein besch digtes Ger t einschalten oder versuchen es zu bedienen Vergewissern Sie sich dass die Chassis Ventilations ffnungen des Ger tes NICHT BLOCKIERT sind Preface Safety Instructions Austauschen einer durchgebrannten Sicherung NUR mit der gleichen Sorte und Belastbarkeit wie sie auf der Sicherheitsaufschrift markiert ist Die Aufschrift befindet sich neben der Stromzufuhr wo sich auch der Sicherungskasten befindet Bedienen Sie das Ger t NICHT an einer Stelle an der die Umgebungstemperatur 50 C bersteigt Ziehen Sie das Netzkabel raus BEVOR Sie versuchen die Hauptsicherung zu kontrollieren oder auszutauschen P117F R Stackable Switch Installation Guide Chapter 1 Overview This guide is divided into four main sections e Overview A general description of the features of the Avaya Stackable Switch and P1
24. isplay Current Version shows the active configuration e Display Configured Version shows the new configuration which will take effect after a reset has been made e Display Default Version shows the system default configuration CR Refresh The Screen Type Enter to clear the screen and re display the current displayed Menu with the updated parameters 1 Reset the Module If you have changed certain parameters of the P117F R the P110 NMA or other switches in the stack you must reset the agent before you exit the Setup session The following lists the resets you must initiate and the resets performed automatically by the agent Resets the user must initiate Resets performed automatically by the agent After setting ATM port The first time you set VLANS parameters to their default values Change in the Use switch Set Ethernet ports parameters to or any other DIP switch of their default values any other switch After changing the LSV DIP Switch position Resetting does not affect any other parameters You will be asked to confirm the reset before it is executed Reset the Agent Confirm y n P117F R Stackable Switch Installation Guide 17 Chapter 3 Configuration 2 Software Download General When you receive the P117F R its on board agent comes pre loaded with fully functional software New software is made available at regular intervals You should make sure that all P110 units contain the
25. le not found Failure of TFTP Get Type in the correct filename server is Failed to find the Type in the correct TFTP Server IP unreachable server after 1 minute address Ensure the server is accessible to the agent by typing ping ip address of agent Alternatively if a router is required to reach the server type in the router address from the IP Routes menu explained on page 24 P117F R Stackable Switch Installation Guide 21 Chapter 3 Configuration 3 Agent Access Addresses This parameter stores IP addresses for the P117 agent s communication interfaces in stand alone mode The interface addresses facilitate communication between the agent and the management station By assigning an IP address to the agent interface you make that interface available for agent manager communications The agent also stores a Netmask for each communication interface The Netmask defines which portion of the IP address represents the network ID and which portion represents the Host ID or network node Bits in the Netmask are set to one for all bits that correspond to the network portion of the IP address i e 255 in decimal Bits in the Netmask are set to zero for all bits that correspond to the Host ID of the IP address i e 000 For example if IP address 135 49 60 115 is assigned a Netmask of 255 255 255 000 it means that 135 49 60 defines the network in this case a subnet and 115 defines the actual node host on that n
26. les Make sure you securely fasten the cables to the connectors Cabling Requirements e For correct operation the P110 Exoplane must be fully connected with all units powered up In a stack configuration the P110 NMA must be installed and connected to the P110 Exoplane Failure to observe this requirement will cause the P110 units to block all traffic on attached stations and segments e When using the P114T or P114F in the stack make sure all switches in the stack are connected using P110 Exoplane cables part number 108362203 with white connectors and marked C S B of the type supplied with the new P110 switch Extra cables can be ordered from your local Avaya representative Figure 2 Rear view of a P110 stack showing how the switches are linked via the P110 Exoplane cables A P110 NMA resides in the uppermost switch MN P110 Exoplane Cables e 3 Gk E Co CETTE fer HERE Terminators on 6 Two terminators are supplied with the P110 NMA Insert the two terminators into the lowest two connectors at the bottom of the stack as shown in Figure 2 7 Turn on the mains power to the stack by individually switching on each switch 8 Connect the cables to the front panel
27. ng the UNI Version 1 Select Change configured UNI version Current UNI version 0391 Configured UNI version 2 333 Default UNI version NEC sil gt gt gt Enter new version 0 for 3 0 1 for 3 1 0 gt gt gt PRESS Enter to continue 2 Enter the new version 0 for UNI version 3 0 or 1 for UNI version 3 1 and press Enter to cancel do not enter a value and press Enter 3 Press Enter to return to the UNI version menu You will need to reset the unit in order to implement the change P117F R Stackable Switch Installation Guide 31 Chapter 3 Configuration 9 6 ATM Physical Media This option allows you to change the ATM media to be SONET or SDH To access the ATM physical media menu select ATM Physical Media Before choosing the ATM Physical Media check that the ATM switch supports this media type ATM physical media menu Visage 16155 R S W Version Slot d CR Refresh the screen Return to Previous Menu Display Current M Physical Media Display Configured M physical media Display Default M physical media Change ATM physical media Enter your choice Changing the ATM Physical Media 1 Tochange the media choose Change ATM physical media Current ATM Physical media Configured ATM Physical media Default ATM Physical media gt gt gt Enter new value SDH or SONET Updated Now SDH WARNING ATM physical media changed Reset the agent
28. nter 0 to return to the previous menu or lt CR gt to continue 14 P117F R Stackable Switch Installation Guide Notes Chapter 3 Configuration Press Enter to view the Setup Main Menu e The following Setup Main Menu is correct for a stand alone P117F R module without an NMA agent card inserted e An NMA module is required in a stack configuration In this case options 5 and 6 are set via the P110 NMA setup menus and options 8 through 15 are renumbered 6 to 12 e The ATM Redundancy option appears only in the P117FR The numbering of the menu items will change accordingly Setup Main Menu Cajun P117F S W Version Return to Agent Description screen Reset 1 2 3e 4 5 6 7 8 9 10 11 12 the Module Software Download Agent Access Addresses IP Routes SNMP Community Permanent Managers Module Advanced Configuration 5 UNI Version 6 ATM Physical Media ILMI ATM Address ECS ATM address ELAN configuration ATM Redundancy Set ATM port parameters to their default values Set Ethernet Ports parameters to their default values Enter your choice P117F R Stackable Switch Installation Guide 15 Chapter 3 Configuration How to Navigate through the Setup menus 16 e All Setup menus conform to the following display conventions This symbol Ba EJ This item has a sub menu This item has a sub menu to insert parameter values 1 5243
29. own as This is known Bank A as Bank B USE SWITCH Not applicable for future use only P117F R Stackable Switch Installation Guide 5 Chapter 2 Installation Installing the P117F R Stackable Switch The procedure for getting the P117F R Stackable Switch up and running depends on whether the switch is to operate in standalone or as part of a stack Standalone Operation Plug n Play Getting the P110 switch working is quick and easy 1 Connect the power cable to the switch 2 Connect the cables to the front panel ports The switch is now fully operational To ensure proper ventilation ensure that the P110 NMA slot is closed Keep the P110 Exoplane cables that came with the P110 switch in a safe place You will need them when you add another switch to the P110 stack The P117F R contains an on board agent The Software Download section on page 13 explains when you need to upgrade the on board software to a higher version Stacking Operation Before beginning to operate with the P117F R you need to allocate it an IP address Please refer to Agent Access Address on page 22 To make the P117F R work as part of a stack the P110 NMA with the correct software version is required See the P117F R Stackable Switch Release Notes for the required version Also the on board agent must have the same agent version number as the P110 NMA To check what software version you have see the agent configuration window in CajunView on U
30. ports P117F R Stackable Switch Installation Guide Chapter 2 Installation The P110 NMA and the on board agent in all P110 switches e g P117F R and P113F must have the same version number 8 P117F R Stackable Switch Installation Guide Chapter 2 Installation Rack Mounting P110 switches slot into a standard 19 inch rack If the switches are to be rack mounted first place them in the rack then connect the P110 Exoplane as follows 1 Snap open the ends of the front panel to reveal the fixing holes 2 Slotthe switch into the rack Insert the switches into the rack so that the switches in a logical stack lie directly on top of each other Ensure that the P110 screw holes are aligned with the rack hole positions exactly as shown in Figure 3 Stacking them in this way will allow the switches to be easily connected using the Exoplane cables 3 Secure the switch in the rack using the screws Use one screw on each side Do not overtighten the screws to avoid damaging the plastic Figure 3 P110 rack mounting arrangement e Use only one of the two holes e o e Key Hole in rack Screw hole in P110 Screw position 4 Connect the P110 Exoplane cables as described above and as illustrated in Figure 2 5 Snap closed the hinged ends
31. ted Working on back up power supply Agent OFF No agent in this module ON This module contains an active agent RED REDNMA Reserved for future use CPU OFF CPU is OK Eee Blink CPU is faulty Function LED sd LED Port LED 1 to 17 Link status Port Disabled Port is enabled and link is OK Blink once Link Test Fail Blink Partition Ethernet only twice Collision OFF No Collision ATM is always OFF ON Collision occurred on line Ethernet only Transmitto OFF No activity line ON Data transmitted Receive OFF No activity from line ON Data Received Half Full Half duplex connection to port P117F R Stackable Switch Installation Guide 11 Chapter 2 Installation LED Indicator duplex Ethernet only ON Full duplex connection to port ATM is always ON Table 4 Meaning of the additional P117FR front panel LEDs LED Function Status Meaning Indicator Master port Port LEDs These Port LEDs indicate status Upper ATM for the according to the functional LEDs see connector ATM ports Table 3 Secondary port Lower ATM connector Redundancy status Redundancy is disabled Upper port active Redundancy is enabled Upper port active Redundancy is enabled and secondary port Lower ATM connector is active 12 P117F R Stackable Switch Installation Guide Chapter 3 Software Download to the On Board Agent The P117F R contains an on board agent This agent does not use the same software as the P110 NMA
32. ue These parameters allow you to view the status of the connection between each LEC and its ELAN The Association Status column will always display Active This column is reserved for future use The Leclf status column displays the status of the LEC The status may be one of the following states e Initial State e Initial Registration e Configure e BUS Connect e Join e Operational 2 Press Enter to return to the ELAN configuration menu 36 P117F R Stackable Switch Installation Guide Chapter 3 Configuration Displaying Default ELAN information The default ELAN is the ELAN associated with VLAN 0 1 To display the default ELAN information select Display default ELAN information Default ELAN information VLAN 0 Association 1 Elan name default Assoc Status Active LecIf Status operational IfIndex 1028 Enter CR to continue 2 The Association value is the Index value which appears in the left hand column of the ELAN VLAN associations list 3 Press Enter to return to the ELAN configuration menu Changing the Default ELAN Name 1 To change the default ELAN name select Change default ELAN name ELAN information for VLAN 0 Association T Elan name default Assoc Status Active LecIf Status operational IfIndex 1028 gt gt gt Enter new default ELAN name alpha gt gt gt Enter CR to continue 2 Enter the new default name and press Enter 3
Download Pdf Manuals
Related Search
Related Contents
Page 1 Page 2 このたびはカワイ電子ピアノを お求めいただきまして H:\国际销售部\亚洲区\PO#1B0634 BS-705\bs-705 user manual-说明书 BKM-21D - BroadcastStore.com Notice d'utilisation Operating instructions CoolMax NB-400 Xerox WorkCentre 6505 User's Manual Fukui Computer Application Gembird A4-BT-630-3 mice LG 47LA6205 47" Full HD 3D compatibility Smart TV Wi-Fi Silver LED TV Copyright © All rights reserved.
Failed to retrieve file