Home

Aiphone GF-1D Installation Manual

image

Contents

1. Blank panel Address panel Address module Joint pipe x 2 i Directory card Metal plate GF H Rain hood plate amp paper 1 GF C 80cm 3 1 8 i Connector connecting wire Do not discard Open a hole in the wall for mounting back box es It is suggested to mount the back box at the height of 150cm 5 up to box center Allow a space of 2mm 1 8 or more on each side of back box in the wall BACK BOX DIMENSIONS BANT Module back b bled Two module back boxes x2 Three module back boxes x3 DM RU KON een Joint pipe ea 2 Back boxes W mm W inch fv One row 110 4 5 16 Joint pipe 2 Two rows 245 9 5 8 Three rows 380 15 Four rows 515 20 1 4 275mm Five rows 650 25 9 16 11 5 8 Six rows 785 30 7 8 Seven rows 920 36 1 4 Eight rows 1055 41 9 16 Nine rows 1190 46 1 8 anpa Fonsi 25mm For best results the back box es must be 15 1 1 1 mounted strictly horizontally w 44mm W 44mm 1 3 4 Mount back box e than Mount back box not more than m 1 2 in recess 2 MOUNTING ENTRANCE STATION Front frame amp panels Modules on bracket jj pea Insul Sins EIL pause 3o Vy OOOO a Assemble panels of speech amp call SW modules into front frame from the back i Hexagonal wrench supplied w GF BC a i o Se cee los
2. 0801 A e Al PHONE TWO WIRE BUS APARTMENT SYSTEM GF SYSTEM This Manual is enclosed in GF BC Bus Control Unit box Operation Manual is enclosed in GF 1D Apartment Station box Before actually installing the equipment the contents of this Manual must be thoroughly read and understood Installation Manual containing instructions for wiring amp programming INSTALLATION MANUAL GF DA amp GF DP Eum Speech module amp Panel Sum GF SW amp GF 1 4P Lu Call SW module amp Panel E J9 GF 2F or GF 3F Lo 2 or 3 module Front frame L 36 GF 1D n After installation please keep the O GF BC Apartment station Lo GF 2B or GF 3B Bus control unit 9 2 or 3 module Back box Z as well as WARRANTY Precautions on Installation amp Wiring A WARNING Negligence could result in death or serious injury to people A CAUTION Negligence could result in injury to people or damage to property N WARNING 1 These devices are electrical Wiring must be performed by qualified personnel S 2 Do not modify or alter the equipment 3 Do not connect any power source other than specified to terminals Doing so may Q cause fire or damage the unit 4 The equipment must not be exposed to water or any other liquid 9 5 Make sure wires are connected properly before plugging the power supply into an electrical outlet S 6 AC outlet must be away from moisture and dust S ZN CAUTI
3. to each apartment consecutively and program each handset station in the same manner as in Step 2 Step 4 when completed press PROGRAM switch on E BN Do not forget to replace GF DA Speech Module again to finish the the rubber cap programming To correct wrong setting Apartment station Entrance station Lift handset Keep pressing a call button to clear until a continuous tone is heard Consecutively operate same way for next call button if any Following Step 2 gt Reset on apartment station s that have been cleared For 2 station apartment e Clearing a call button cancels programming for two stations correctly set or not Individually reprogram both stations TECHNICAL PRECAUTIONS Temperature GF Entrance station 10 C 60 C 14 F 140 F GF BC 0 C 40 C 32 F 104 F GF 1D 0 C 40 C 32 F 104 F Rain hood option GF Entrance station is weather resistant but for best results it should be protected from direct weather conditions Install a rain hood GF H to protect it from direct rainfall Filling in name amp Fill in directory or address on the transparent plate with an oil soluble pen etc and attach the address plate to module Plate or paper y Plate or paper Pressing on either side Pressing on either side idR Maio ebd recon plate doting address plate or Pooler OMEN M iu Setting up after In case an apartment station is replaced after all the
4. ON 1 Do not install or make any wire terminations while power supply is plugged in or it could cause QO electrical shock or damage the unit 2 Mount the intercom on wall in a convenient location but not where it could be bumped or jarred 3 Do not install the unit in any of the following locations as it may cause the system to malfunction High or extreme cold temperature area under direct sunlight near equipment that varies in temperature in front of air conditioner inside a refrigerated area etc Places subject to moisture or humidity extremes Places subject to environmental conditions such as oil dust chemicals salt etc Places subject to constant vibration or impact GENERAL PRECAUTIONS 9 General Prohibitions S Prohibitions to subject the unit to water Q Prohibitions to dismantle the unit 1 The equipment except the entrance station is designed for indoor use only Do not install them outdoors 2 The system is not operable during a power failure 3 In areas where broadcasting station antennas are close by intercom system may be affected by radio frequency interference 4 Keep all wiring at least 30cm 1 away from AC100 240V wiring fluorescent lighting or dimmer switches Otherwise cross AC wiring at a 90 angle SYSTEM COMPONENTS Apartment station NI OPTION Doorbell Button GF 1D Apartment station Packet of screws OPERATION MANUAL Entrance sta
5. d Open the rubber cap Then push pP a Ee E LU PROGRAM SW momentarily When front panels are already mounted open unscrewing the bottom screw Turn on power switch of GF BC Power switch Breaker Hexagonal wrench SETTING FOR LIGHT button OPTION In use LED Lj In use LED Wait for approx 15 sec and see the LED steadily lit ie S While In use blinks iet SII Or ly within 15 sec press an ae 9 assigned call button A 2N Note At the rest Entrance stations the in use LED is steadily lit and blocks out any calling pA Unscrew Hexagonal wrench oS SER eet seas E a Step 2 At an Apartment station 1 lift handset Communication channel is established with Entrance station instantly Hearing single BEEP tone means the station correctly set Hang up handset Apartment station 1 Entrance station BEEP TONE E Call button 1 Apartment 1 is set BEEP tone b LIGHT button is set 5 Turns on entrance light 6 controlled by MAW B EPUM e relay S Hexagonal wrench WP Press a first call button For a second station if installed lift second handset and press the same call button 1 Beep tone sounds twice Second Apartment station 1 Entrance station DOUBLE BEEP TONE Call button 1 Apartment 1 2 is set Hexagonal wrench Press a first call button Step 3 Go
6. e ooo See eo te Roe ee SC ice m Qa e micum eee mimm e ee i E Ey i I M eme Remp eg Jui SoS ee oa E E a A a ee Become Cm aS eee a Sem ee ees Oo eee Attach the Modules onto Plug the wires into connectors Mounting Bracket between the Modules System wiring Remove terminal cover Ls Always run the wire under the plastic cover for drainage Interconnecting Modules with Plug in Connectors As shown the Modules 1 Connect the Modules 2 Pass the connecting wire through joint pipe pre must be connected in a as shown in drawings opened and plug to CN1 of Call SW of next row daisy chained manner us ji Next Speech module Back view f l CN4 i CN1 l CN2 Call SW CN1 osos CalSW CN2 modules CN1 p CN2 CN1 CN2 P Back view CN2 Plug into CN1 Locating Speech module GF DA in the middle row GF C 80cm 3 1 8 1 7 connecting wire In advance pass a 80cm 3 1 8 long connecting wire through joint pipes MOUNTING amp WIRING GF Entrance Station SETTING Entrance Z SET switches To set for Entrance stations 1 5 set DIP switches on Speech Module GF DA as shown below All the Entrance stations will malfunction if positioned in any o
7. me panel to To release a conductor Metal plat the bracket press UNLOCK button TAIP ae then pull the conductor Mounting eS j Light bracket 1 ge Adjustable screw holes UNLOCK button 9 9 00 99 6 9 l 9 9 9 o6 9 9 Hexagonal Metal plate l wrench SCT next apartmens 3 2 1 Ri NP APARTMENT r See next page T Y d g GF 1D GF 1D GF 1D 1 ii e Mii To next apartmens L A L A l Qa GF 1D GF 1D GF 1D AC power line CONTROLE APRO E 4 PS 24ME AC 230V input POWER o JU eo CO SUPPLY 0HH0HH00 UUUUUUU fe o O ToS 000000 ERE BR i e Ll Do 92 DC 24V np R1 i R2 CERES ra 0 9A output E Red Black white O Blue x uum Option unused Ju
8. nction point MAW B Helay R2 Light control Orange Orange uer ome For controlling light at the entrance AC use Aiphone s MAW B relay which provides dry closure contact MOUNTING Me Reit UNE m 77 s 777 ITE Switch Power on LED green LE DIN rail Y Pull down lever k gt nnd DIN rail for GF BC inal W DIN11 available from Aiphone Use when DIN rail is not provided Terminal cover HOW TO RESET BREAKER Power switch ON n Power When system malfunctions check the wiring Check the fuse of power supply OFF switch Turn off the power switch of GF BC and turn on again resetting the whole am system operation eo Green LED lit Ln Apartment station Apartment 3 Apartment 1 Apartment 2 Chassis inside view 1 Doctor call Auto door strike upon visiting patient call in JPi c At the Apartment station remove JP1 jumper Press LIGHT button and see Call tone off indicator blinks Press LIGHT again to release Call tone off indicator goes out Note At the station set for Doctor inlPethole a eee 1 call it is not possible to control entrance light with LIGHT button 2 Connect Doorbell Button only to either one of two apartme
9. nt stations to avoid malfunction Provides dry closure contact for ringing while the Doorbell button is held down to Bus control unit Junction point Employ a terminal block of adequate size to distribute multiple Bus lines to GF DA Speech Module Adjusting call tone volume or off MOUNTING Call tone volume can be adjusted to 3 positons It is suggested to mount the station at the height of 150cm 5 from the floor MUTED MID HIGH When the control is set to MUTED position Call tone off indicator blinks 1 Cable ta Notes inlet hole fs 1 Cut out a hole for surface Call tone volume Single gang box cable run l control 2 SERVICE button terminal E block amp switch is optional 7 83 5mm 3 To avoid pinching keep wires 3 5 16 away from PC board section V i dec H rm A d iad gea 2 cd e i w 1 or round X gang box MUTED HIGH 60mm U MID G 2 31a Bottom view Loosen a screw on front case Lift the front case off the chassis and pull it away Mount chassis on an electrical box Connect incoming wires on terminal block Remount front case on chassis tightening the screw SETTING UP SYSTEM Prior to setting up GF system make sure all the stations have been installed and wired in proper manner Leave the front frame amp module panels unattache
10. point to GF 1D farthest 300m 980 Junction point to Entrance station 300m 980 Total wiring distance 2 900m 1 5 miles GF BC to Power supply 5m 16 GF BC to Junction point bm 16 MAW B to each GF DA light amp power supply 300m 980 Bus line capacity Multiple Bus lines divided at junction point Apartment station max 50 on a Bus line sin ity Entrance station max 3 on a Bus line station capacity Per system 150 pcs in total Apartment station Ber apartment max 2 pcs Per system max 5 pcs GF DA Per panel max 25 pcs GF SW Door release terminals EL EL rated less than 4A resistance load AC DC 24V for dry closure contact for door release Si i lS iS i dep dob op qoc op do Moe de qo Qo opp i eaae aiid 4 WARRANTY Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period 4 of one year after delivery to the ultimate user and will repair free of charge or replace at no charge should it become defective upon which examination shall disclose to be defective and under warranty Aiphone reserves unto itself the sole right to make the final decision whether there is a defect in materials and or workmanship and whether or not the product is within the 4 warranty This warranty shall not apply to any Aiphone product which has been subject to misuse neglect accident or to use in violation of instructions furnished no
11. r extended to units which have been repaired or altered outside of the factory 4 This warranty does not cover batteries or damage caused by batteries used in connection with the unit This warranty covers bench repairs only and any repairs must be made at the shop or place designated in writing by Aiphone T Aiphone will not be responsible for any costs incurred involving on site service calls sete ste cde ede ofe ede nde ofe ole nde ole ole ate ole ale te de de ede nde ofe ojo ofe ndo ofo ndn ofe ofe ole de dn de de cde efo ode ede ale ole ofe ofe aie to tn on do cde cde do cde ede odo ofe ale ale steele ele ofoofo ofe AIPHONE CO LTD NAGOYA JAPAN AIPHONE CORPORATION BELLEVUE WA USA o Al p iad Oo N E AIPHONE EUROPE N V ANTWERP BELGIUM Providing Peace of Mind PEERS 8 Printed in Thailand E Entrance station FEEEEEES SESE SEES
12. ther manner Entrance station 1 Entrance station 2 Entrance station 3 Entrance station 4 Entrance station 5 GF DA Speech Module Shipped in 1 position Back view Door release timer Mid point Momentary 0 range Shipped in Momentary position 0 5 sec duration Turn counterclockwise completely Tm Turn clockwise to obtain longer second 0 5 20 sec duration of duration 20 sec duration Turn up to the mid point Momentary activation Turn to any point between 20 M Activated as long as the door release button is held down Entrance station 2 Roe GF DA a A pad d d d Speech Module Em i Back view to MAW B Light of Entrance 1 IU See page 5 for wiring 5P connector s from upper socket AC DC 24V AC DC 24V of a module below less than 4A less than 4A coat resistance load resistance load AC PT E Doar relesi Ac PT Electric Door release PT Power transformer Put a conductor into insert When mounting multiple rows of panels After wiring amp setting mount the lock terminals attach the metal plates and tighten screws on module mounted bracket to back box the brackets Finally attach front fra
13. tion FRONT FRAME GF 3F 3 module fro Mounting b nt frame racket Packet of screws Weather stripping for reinforcement GF 2F 2 module fro Mounting b nt frame racket Packet of screws Bus control unit amp Power supply p OPTION o m GF BC PS 24ME AC 230V PS 2410LC AC 120V MAW B Two wire Bus control unit Power supply PS 2410LD AC 230V Relay for Packet of screws Packet of screws external light INSTALLATION MANUAL e DIN rail Be Hexagonal wrench Terminal cover Fuse PANEL MODULE BACK BOX a nmm j MEZ j 0 W fial GF DP GF DA Panel only Speech module if T Connector d M S90 GF 1P 1 call button panel GF 2P GF 4P 4 call button panel GF 3P 3 call button panel 2 call button panel GF SW Call switch module Directory card plate amp paper Connector m GF 3B 3 module back box Packet of screws Joint pipe x 2 Metal plate pe Do not discard GF 2B 2 module back box Weather stripping for reinforcement GF BP GF AP GF AD Packet of screws OPTION
14. wiring is done turn the power switch off replacement and back on again on GF BC Then reprogram that apartment station only Operations At the end of communication hang up the handset on cradle If a handset is off the hook call tone will still ring at two stations But for approx 45 sec after called the inside audio is activated on that apartment station and heard at the entrance Momentarily hang up handset and resume communication While an apartment station rings with a call from an entrance station a call from the doorbell button will not be heard Cleaning Clean GF equipment with a soft cloth dampened with neutral household cleanser Never use any abrasive cleaner or cloth SPECIFICATIONS Power source DC 24V GF BC supplied by PS 24ME or a power supply as specified Current consumption Max 700mA Standby 30mA 8 call one entrance Call in tone Two types of call tones one from entrance station the other from doorbell button distinguishable Talk path Single channel non open Communication Simultaneous with handset no calling or communication between apartment stations Wiring 2 wires common Bus GF BC to Entrance station s amp Apartment stations via junction point throughout system Type of Cable 2 conductors solid copper amp non braided polyethylene insulation 0 8mm dia 1 6mm dia 20AWG 14AWQ Wiring distance Diameter of wires 0 8mm dia 20AWG Junction