Home
        Operators Manual
         Contents
1.                www alltraxinc com    Operators Manual    Model  AXE Series    Series Wound DC Electric Motor Controller       2005 ALLTRAX INC     AllTrax inc   1111 Cheney Creek Rd  Grants Pass  OR 97527  USA  Phone  541 476 3565   Fax  541 476 3566  www alltraxinc com    PN  Doc100  003 A_OP AXE Operators Manaul doc  Rev A     Table of Contents    1  AXE MOTOR CONTROL PRODUCT OVERVIEW                     cccccccccccccccccccccccccccccccccccccccccccccccccccccccccecs 3  Ze REQUIRED ACCESSORIES oia A A A canines 4  Ss BATTERY CONTACTOR  SOEPNOID OR RELAY Mision 4  Dee MAIN FUSE  PROVIDED WITH CONTROLLER EE 4  e SAFETY EE nee eer eebe 5  2 4 DEVEM TOR So haste ake dca al ps ase pan a ce clado a ees 5   3  CONTROLEER INSTALLATION oda is 5  3 1 CONTACTOR    OUD ODEs a a a Shas a aa esos Gauls 5  32 TORE  C HAR GE RESISTOR nia Mee E 5   4  LEDSTA TUS INDICA  TOR a eset en areas 6  SOFTWARE USE AND CALIBRA TION EE T   6  PROGRAMMING THE CONTROLLER    consi ee Ee 8  6 1 CONTRO ANE De  AB sms ebro entran 9  6 1 1 SWHCHES E 9   6 1 2 SETLINOS EE 10   6 2 THROTTLE RESPONSE  TAB dates 11  OZ e EE ll   6 3 MONITOR TAB EE E 12  6 3 1 MOn TOT E 12   6 3 2 TECH EE 12  EE Eege 13   7 LIMITED WARRANTY una ida 14    Keep this manual    All Trax Inc  Doc100 003 A_OP AXE Operators Manual Page  2 of 14    1  AXE Motor Control Product Overview    Thank You for purchasing the Alltrax motor controller  We design and manufacture products for  a variety of electric vehicles and markets  This motor cont
2.      C Progressive    f    Inductive  e       6 2 1 Throttle Sensor Type    0 1K Ohm  Yamaha type    When selected  the controller interprets 0 80 ohms   throttle off  1K ohms   full on     0 5K Ohm   When selected  the controller interprets 0 ohms   full off throttle  5K ohms equals full on   Specifically  Zero ohms to 180 ohms   full off  4 7K to 5K   full on     5K 0 Ohm   When selected  the controller interprets 5K ohms   full off throttle  0 ohms equals full on   Specifically  Zero ohms to 250 ohms   full on  4 3K to 5K   full off     0 5V   This selects a voltage controlled type of throttle input  OV   full off output from  controller  5V   full on  Actual operating range is 0 15    4 90V     6 10 5V  Taylor Dunn type    This throttle sensor is voltage controlled  0 6V   throttle off  10 5V   full on     5K 0  3 wire  Club Car type    This throttle sensor employs a 3 wire potentiometer  or the V Glide throttle position unit   5K   throttle off   lt 200 ohms   full throttle     EZ GO ITS   This throttle sensor type is compatible with the EZ Go type of inductive throttle position  sensor  ITS     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  11 of 14    Throttle Sensor Type Continued   Pump   This throttle setting allows the AXE controller to power pumps used on fork lifts and  other hydraulic applications where pumps are used  The controller turns on 100  output  when the Pin   spade lug sees pack voltage  The ramp up and ramp down rate is still  controlled by 
3.  input to B  bus  bar of the AXE controller  Accuracy      5     Output Current   This is the measured output or motor current of the controller  accuracy    10     Battery Current   This is the calculated input or battery current to the controller  It is calculated as  Battery  current   motor current x throttle position    Itis accurate  given that motor current is  continuous  which it generally is with any series motor   not discontinuous  Accuracy       10     Error Flags   This register should display as 0x00 during normal operation  Any value greater than  zero is an error  and the controller will not provide any output power   At the moment  this data is in hexadecimal format  If the two right most hex digits  those  to the right of Ox  are converted to an 8 bit binary value  the individual bit positions  with  bit O being the right most digit  when set represent the following error flags     Bit O set   Throttle Position Sensor Over Range   Bit 1 set   Under Temperature  Controller below  25C   Bit 2 set   HPD  Throttle hasn   t gone to zero during this power on cycle   Bit 3 set   Over Temperature  Controller over 95C   Bit 4 set   unused   Bit 5 set   Battery Under Voltage detected  Battery V  lt  under voltage slider  Bit 6 set   Battery Over Voltage detected  Battery V  gt  over voltage slider  Bit 7 set   Controller in boot sequence  Occurs within 25mS of power up     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  13 of 14    7  LIMITED WARRANTY    Allt
4.  portion of this program will enable the software to work on most PCs  However  in  some very electrically noisy systems  it may be necessary to increase the write delay above 20mS  or increase the number of retries  such that communications errors are eliminated     Tools  This function of the program allows you to modify the main executable program that  operates the controller  to modify the behavior of a standard controller by adding special features  like increased throttle response speeds for go karts  or extract an error log from the controller for  diagnostics     Upgrade  This function loads a new executable program into the controller    Reset  Restarts the controller without cycling the power    Write error log  This function downloads the last 32  if any  errors that the controller has logged  into it   s EEPROM memory  These are things like HPD  hi low battery voltage  and  over under temperature     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  8 of 14    6 1 Control Panel Tab    This tab allows you to alter the operating characteristics of the AXE  Changes made on this pane  only take effect after the    SET    button is pressed     Refresh    will read the current settings from  the controller  After any changes have been    SET     always click    REFRESH    to confirm the  changes were accepted by the controller  Note  HPD and Plug Brake switches only take effect at  power up  the power to the controller will have to be cycled before these two cont
5. 03 A_OP AXE Operators Manual Page  14 of 14    
6. altering the controller  For bench programming prior to installation  two 9V batteries  in series may used to power up the controller  Connect battery negative to the B  bus bar  battery  positive to pin 1   spade tab closest to the LED      When the AXE is connected to the PC  and both units are energized  launch ControllerPro EXE   If you see an error    Motor Controller Not Responding     it means the Controller and PC are not  communicating  Hit    OK     and the Controller Pro will display a window  Recheck the cable  connections then close and re open Controller Pro  Controller Pro automatically determines  which com port the controller is connected to  If  after going through this the controller will still  not establish communications with the PC  try turning the AXE controller off  then back on   Observe the LED on the AXE went out  then came back on  indicating you cycled the power     Restart the Controller Pro program   NW AllTrax ControlPRO    Seite Tos Hem    Conti are   rege Berg   Montar      When communications is established  with the controller  a Model number   like AXE4844  should be displayed    Cariri    ANE oer    in the Control Panel pane  along with  the current configuration of the AXE  motor controller     Hie Duinat Curreri w       Lar aii HED Wen    Tre Wih ED We              breee LE er  Tee Cicer Sen  Beste    Tay Eee                   The top row of functions 1s Settings  Tools and Help  The normal parameters of the    settings   program      
7. breaker  a mechanical switch  or a large removable connector   Make sure it is rated for the current capacity and DC Voltage of your system  Some  installations disconnect both the positive and negative leg of the battery pack  Most Golf type  vehicles do not have a battery disconnect     2 4 Drive Motors    The motor controller is designed to operate with series wound brush commutated and permanent  magnet motors rated for operation from 12 72 VDC  Operation with compound motors is  possible  Contact Alltrax  Inc  for information on using compound motors     3  Controller Installation    Choose a location outside the driver   s compartment to mount the controller  Any mounting  position is acceptable  It is recommended that you protect the controller from direct contact with  water  as the electrical connections can corrode  In high moisture environments  seal the  electrical connections with silicone or grease     Mount the controller as close to the motor as is reasonably possible  Ideally  your motor leads  should be less than 4 feet long  Making a twisted pair out of the motor leads will reduce RF  emissions    e Most car employ small  6AWG  battery interconnect wiring    e For 400A controllers  a minimum of 4AWG wire should be used in light weight carts    e 2AWG to 1 0 is appropriate for higher amperage controllers and heavier vehicles     High current wiring to the motor controller should use 5 16    mounting hole ring terminals of  tinned copper  Bolt them to the con
8. led    Logs     in the same directory as the program Motorcontrol exe    6 3 2 Interval Section     This checkbox selects the update rate  or frequency of data collection  For real time display   select continuous  When used in conjunction with    Log to File     a slower update rate may be  more desirable to reduce the amount of raw data being gathered     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  12 of 14    6 3 3 Gauges Section     These are the motor controller parameters which are to be monitored  Checking an adjacent box  enables that measurement  Clicking    Refresh    will perform a one time update to the gauges  which are selected  It is generally recommended that you select all the gauges  as this will  provide the most insight into the operation of the controller     Throttle Position   This gauge displays the   modulation of the controllers PWM output  For example 50   would be L   throttle  The displayed parameter is the actual throttle position  limited by  the fact that the controller could be in current limit  If the controllers output current  reaches the maximum rating  the throttle position won   t advance any further  regardless if  the throttle is full on     Controller Temperature   This is the internal temperature of the controller  in Celsius  Accuracy      5      Battery Voltage   This is the voltage present across the B  and B  bus bars of the controller  Exception   Club Car compatible models  This is the voltage present across the KSI
9. n 6 10 5V   7 Green   CLUBCAR 5K 0  3 wire   Normal display status    solid Green  Controller ready to run   Solid Red  Controller in programming mode   Solid Yellow  Controller throttle is wide open  controller is supplying max  output  and is not in current limit     Error code display   Number of RED blinks indicates any error conditions that might exist     1 Red   Throttle Position Sensor Over Range  Check for open wires    2 Red   Under Temperature  Controller below  25C    3 Red   HPD  Throttle hasn t gone to zero during this power on cycle    4 Red   Over Temperature  Controller over 95C    5 Red   unused for series controllers    6 Red   Battery Under Voltage detected  Battery V  lt  undervoltage slider   7 Red   Battery Over Voltage detected  Battery V  gt  overvoltage slider     Errors are self clearing when the fault is corrected     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  6 of 14    5  Software Use and Calibration    The Alltrax Motor controllers utilize a computer program to provide the motor drive functions  motor field  current mapping  and a myriad of other customizable features such as speed  current  throttles  etc     A majority of the Alltrax motor controllers also have the ability to be re programmed with upgraded  software  In most cases  it is not necessary to upgrade the unit s software for stock or aftermarket  replacements unless a specific revision is needed for a particular application     See Controller Pro Operators manual for mo
10. n damage to the controller  and serious injury or death to vehicle  occupants or bystanders    2 1 Battery Contactor  Solenoid or Relay   The main battery contactor needs to be rated correctly in terms of amps and volts  in order to   safely carry the intended continuous battery current  and to interrupt the pack DC voltage  It   s  coil voltage should also be rated for the pack voltage        2 2 Main Fuse  Provided with Controller   e The main fuse needs to be sized to protect the wiring in  the drive system     e Fuse DC voltage rating must be greater than the peak  battery voltage        e Fuse current rating equal to or less than amperage  rating of controller     Most high current fuses have very long tolerance  2 minutes or more  up to 50   100  overloads   Thus a 300A fuse likely won   t open in a 500A vehicle application  Most Golf OEM vehicles  may not have a fuse and must be added with these performance controller upgrades  When carts  are equipped with large controllers  the wire gauge must be made larger  This in turn permits  higher fault currents  due to the reduced wiring resistance  Under these conditions  we strongly  recommend the addition of a fuse to prevent catastrophic battery failure or fire m the event of an  electrical system failure     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  4 of 14    2 3 Safety Disconnect    The safety disconnect provides a way to disconnect the battery pack from the controller and  contactor  It may be a circuit 
11. rax  Inc  warrants every product it sells to be free from defects in materials or workmanship  for a period of 2 years from the date of manufacture  This warranty does not apply to defects  due directly or indirectly to misuse  abuse  negligence  accidents  repairs or alterations  We shall  in no event be liable for death  injuries to persons or property or for incidental  contingent or  consequential damages arising through the use of our products  Alltrax  Inc  specifically  disclaims the implied warranties of merchantability and fitness for a particular purpose  however  some areas do not allow limitations on how long an implied warranty lasts  so the preceding  exclusion may not apply to you  This is Alltrax  Inc  sole written warranty  no other warranty is  expressed or implied    In the event you should need warranty repair  Please see the Return Procedure below  Alltrax  reserves the right to repair or replace merchandise at its option  Alltrax reserves the right to  make changes to any of its products or specifications without notice     Return Procedure     Call Alltrax  Inc  at  541  476 3565  Fax us at  541  476 3566  Or visit us on the Web at www alltraxinc com    Explain the nature of the problem to our service personnel and we will provide you with  return directions You pay shipping to us  we pay the return shipping  Package the  device securely in original shipping box if at all possible  we are not responsible for  damage in shipping     AllTrax Inc  Doc100 0
12. re detailed operation   Software     e Controller Pro Software  see www alltraxinc com and download    http   www  alltraxinc com old Software WEBControllerPRO zip             Through may customer service calls we have found 90  of the problems with communicating  between the computer and the motor controller was the inability of the windows software to  assign communications ports  We found using a USB to Serial Adapter eliminated any  communications port issues with success to connect properly the first time     Recommended serial to USB adapter     e Cables to Go  Port Authority    2 USB to Serial Adapter  www cablestogo com  shown  above     e Radio Shack  6 Ft   1 8m  USB to Serial Port Cable  Model  26 183  Catalog    26 183   Shown below     WARNING  Disconnect all battery charging sources  while programming your Axe Controller    The controllers RS 232 serial port is referenced to the B   battery connection     Beware any possible ground loop faults between your  computer and the controller which could damage both the  Axe Controller and PC  plus the person doing the work        AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  7 of 14    6  Programming the Controller     The AXE controller must be powered up before the Controller Pro program will have any effect   Any programming changes done in the vehicle should be performed with the vehicle safely  disabled  Either put the drive wheels on jack stands  or position the vehicle where it is safe to  drive while 
13. roller employs modern power  MOSFETs to provide extremely low    on    resistance  in both the main switch function and  freewheel diode     Synchronous freewheel rectification permits extended high power operation  over similar sized controllers due to increased efficiency  A microprocessor  based control system monitors numerous functions  and a windows interface  allows the user to change numerous operating parameters and perform status  monitoring           Replaces Curtis Replaces Curtis  1204  6 5    long  1205  8 5    long        AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  3 of 14    2  Required Accessories    These components are not supplied with the controller  except the main fuse  For your safety  and that of others  some basic precautionary measures must be employed when designing   working on  and driving electric vehicles     e Use a contactor in the battery circuit  rated for the amperage and voltage of the system    e Use a fuse rated for the voltage and available fault current of the battery  such as the one  provided    e Safety interlocks must be employed to prevent enabling the controller while the vehicle is    unoccupied or charging     Controllers have failure modes which can result in runaway  stuck throttle  conditions  This  controller has been designed to prevent and preclude as many of those from ever occurring as  possible  Please follow the Recommended Controller Wiring System document in this manual   Failure to do so could result i
14. roller reduces it   s output current in response  to a decrease in throttle position  O is the slowest  15 the fastest  It is recommended that  this parameter typically be set to twice the value of the throttle up rate  when throttle up  rate is less than 7  Lower values of Throttle Down Rate can result in the vehicle feeling  as if their were a large flywheel connected to the motor     Brake Current    On those models equipped with a plug brake  suffix    P    in the model number   this slider  adjusts the amount of brake current as a percent of maximum available brake current   Refer to AXE specifications for maximum available brake current depending on the  model of controller   Top Speed    Top speed of the controller can be limited from 100  down to 50   This is a helpful  tool for elderly or handicapped drivers     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  10 of 14    6 2 Throttle Response Tab    This pane allows you to select which type of throttle position sensor the controller is working  with and what type of throttle response profile to use with the sensor  Changes to throttle sensor  type check boxes must be SET to take effect  and then only after the power to the Axe has been  cycled do they actually change the sensor type     Control Panel Throttle Response   Monitor      Throttle Sensor Type Set        Yamaha 0   1K   Ce 0 5K Ohms Refresh  C 5K 0 Ohms   f   0 5 Volts   f   6 105 Volts   C Club Car 5K   0   f   EZGOITS   C Pump    Throttle Response
15. rols have any  effect on the machines operation  The    DEFAULTS    button will restore the factory default  values of the sliders  note that    SET    must still be pressed for these parameters to be stored in  the AXE controller     Control Panel   Throttle Response   Monitor      Controller Switches  Model UNKNOWN M High Pedal Disable   Serial E   Plug Brake  Field Map     Turbo         1 2 Speed Reverse    Settings   Max Output Curent D   In  Under Voltage 16 0 Volts Te   Over Voltage 30 0 Volts    _   _   _   _   _   _   _   _   _   _   _   __  Throttle Up Rate D Te  Throttle Down Rate D In  Brake Current DS     Top Speed 50 0   Blom   L        Fast       6 1 1 SWITCHES     High Pedal Disable  Checking this box enables HPD  which will prevent the controller from providing output  power in the event the throttle is applied when the controller is powered on  When this  box is clear  the controller will start up and provide output power  when KSI energized   regardless of initial throttle position     Plug Brake  Checking this box enable plug braking on those controllers equipped with an A2 bus bar  terminal  Plug braking on AXE controllers is proportional to throttle position  reaching  full braking force at about 25  of throttle travel  Deselecting this box disable plug  braking  the unit will apply normal power to motor if direction is reversed   vehicle may  jerk or spin tires if motor direction is reversed while in motion     Turbo  A feature that allows DCX controller
16. s  not AXE controllers  to go faster if under light  load and 100  throttle        Y Speed Reverse  Limits speed of golf car to 50  of throttle setting when pack   is applied to this pin     AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  9 of 14    6 1 2 SETTINGS     Maximum Output Current    This slider adjusts the maximum output current that the controller can provide to the  motor  Output current is adjusted as a percent of the maximum rating of the controller  For example  an AXE4844 will provide a maximum of 400A to the motor when this  slider is set to 100   A 75  setting on Maximum Output Current will limit the  controller to 300A  50  will limit the max output current to 200A and so forth     Under Voltage    This slider sets the under voltage shutdown of the controller  in units of 1 10ths Volt   Generally speaking  it is undesirable to pull the terminal voltage of a 6V lead acid  battery below 4 0V  for example 24V on a 36V system     Over Voltage    This slider sets the maximum operating voltage of the controller  If the voltage present  across the B  to B  bus bars exceeds this setting  the controller will not produce output   given that DC voltage is below the absolute ratings of the controller     Throttle Up Rate    This slider adjusts the rate at which the controller increases it   s output current in response  to an increase in throttle position  1 is the slowest  15 the fastest     Throttle Down Rate    This slider adjusts the rate at which the cont
17. the two sliders on the Control Panel     6 3 Monitor Tab    This screen is the status monitor of the Axe controller  it gives you the ability to measure and  record numerous operating parameters of the Axe motor controller and the vehicle in which it is  installed  When used with a Notebook computer  both real time data display and data logging  may be performed while the vehicle is in use  This gives the vehicle designer significant insight  to the interaction of the motor controller with other system components  Log files may be used  for problem analysis and diagnostics  You can email the log file to Alltraxinc com for a detailed  analysis by our applications engineers     Control Panel   Throttle Response Monitor          Monitor Gauges  Start   lf Throttle Position Mia  if Controller Temperature 2730 TC     W Battery Voltage 00 Volts  Clear All     Output Current 0 0 Amps   Logto He lf Battery Current 0 0 Amps    Error Flags  00  Interval  f    Continuous Refresh   e 1 Second  f   5 Seconds      10 Seconds      30 Seconds      1 Minute       6 3 1 Monitor Section     Start Stop  This starts and stops the data measurement process   Select All  Checks all the gauges   Clear All  Deselects all the gauges   Log to File   This checkbox will log all of the selected gauge values to a file when selected  The file is  in a comma delimited format  CSV  which can be imported into a spreadsheet program  like Excel and viewed  The resulting file will be placed into a subdirectory cal
18. troller using 5 16    hardware     3 1 Contactor Coil Diode     CAUTION  A Diode  1A  100V  MUST BE USED across the solenoid contactor coil  and any  other relays that may be installed to control lights or accessories   The Cathode or banded end  faces the positive terminal  These diodes are required to prevent the speed sensor from  producing erroneous signals     3 2 Pre charge Resistor     The controller has a fair amount of DC filter capacitance  When the contactor closes to apply  power to the controller  the capacitors can arc the contactor  The pre charge resistor wil apply a  low current to the capacitors to prevent any arcing and keep the capacitors at bus voltages  It  also acts as a discharge snubber that helps dissipate the arc when the contactor disengages   see  schematics for proper value      AllTrax Inc  Doc100 003 A_OP AXE Operators Manual Page  5 of 14    4  LED Status Indicator    The AXE controller has a bicolor front panel LED  This LED displays a variety of  information each time the controller is powered up  by series of blinks  Count the  number of green blinks to identify the type of throttle the controller is configured for   After the blink code indicating throttle type  the LED will stay green if there are no errors        LED Blink Codes   At power up the number of green blinks indicates the configured throttle type     1 Green   0 5k  2 Green   5k 0  3 Green   0 5V    4 Green   EZ GO inductive  ITS    5 Green   Yamaha 0 1K   6 Green   Taylor Dun
    