Home
Installation Instructions and User Guide
Contents
1. 7 Kee a OG T Rear bottom left Rear bottom right Top left cable entry cable entry cable entry Note Depending on cable size and entry point used it may be necessary to strip back outer cable sheath sufficiently to allow cables to be directed to the terminal connection block within the unit 12 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Electrical Connections cont Switch OFF the electricity supply at the consumer unit The power cable entry point is shown on the diagram Electrical connection to be made at the terminal block as follows A ise Earth cable to the terminal marked with the Earth symbol G D d fe Neutral cable to the terminal marked N Live cable to the terminal marked L Important Terminals must be fully tightened onto the cables MILLI ensuring that no cable insulation is trapped under the screws It must be metal to metal Loose connections
2. Note The unit can be hung temporarily on the top screws to help with the positioning of the pipe work etc The bottom screw should only be fitted during final installation Important Under no circumstances should this shower unit be recessed it must be fitted onto the finished wall surface or tiled up to or sealed around the unit as this may prevent air circulating and any condensation escaping ie ns L 8 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Plumbing Connections Inlet Entry Options Select the inlet option most suited to your situation S B rs o 5 ORORO ee J NOL O p S E d t Bottom left inlet entry Bottom right inlet entry 4 Sh s S Te o l o J o je o r O T C OLO eeel Aa p cjoe p NOL NOL a
3. Turn on the water supply and inspect for water tightness Turn on the mains electrical supply to the shower Press the STOP START touch button 3 Note The unit has been factory set to first come on in the Cold Power position Only the Cold 8 power touch button 4 should be illuminated when first turned on If not please press the cold power touch button to obtain cold water only Wait approximately 30 seconds for the water to flow correctly Once the water has flowed for a further 10 seconds rotate the emperature control knob 6 from the fully clockwise position to the ully anti clockwise position Repeat this procedure several times until a continuous flow of water with no air bubbles is obtained rom the shower hose Once you are satisfied that the system has been flushed through horoughly press the STOP START touch button 3 to stop the flow Note If the words LOW PRESSURE appear below the large numerical display L his indicates too low a water supply pressure to the unit Please switch off unit until water pressure increases before continuing to use the shower cJ Mu PRESSURE Re fit the showerhead to the hose insert hose rubber washer to seal the joint please ensure that the hose passes through the larger hole in the soap dish The showerhead is attached to the riser rail by inserting the conical hose end into the movable slider Your shower is ready for use N
4. of fuse see table on page 6 Consumer unit For cable capacity see table Mains water supply Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Mains electrical supply Electrical Requirements cont It is a requirement that a residual current device RCD formerly known as an earth leakage circuit breaker ELCB with a tripping current of 30mA is incorporated in the circuit This may be part of the existing consumer unit or a separate unit Please refer to the table below The isolating switch can be a ceiling mounted pull cord switch within the bathroom or wall mounted in an adjacent room The power switch must be easily accessible and identifiable as the supply to the shower The current carrying capacity of the cable must be at least that of the shower circuit Please refer to the table below In domestic installations you must ensure that the electrical supply and existing fuse board are adequately rated Do not turn on the electrical supply until the plumbing has been completed and the shower cover re fitted Twin and Earth PVC Insulated Cable Current Carrying Capacity In an insulated wall In conduit or Clipped direct or trunking buried in a non insulated wall bmm bmm bmm 32A 38A 46A 10mm 10mm 10mm 43A 52A 63A Note Cable selection is dependant
5. 17 Maintena NC eyiini ihulasbahideialaitemstbchtdaned 17 18 TROUBLES MOOUIN eid aa 8 E e E ink nae a En aa E R RENS 9 Service TT 19 Spare Pats escuresir in hd tata e EE E 20 22 Recommended Usage Domestic 4 Heavy Commercial X Light Commercial X Health Care X 2 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Important Safety Information e Please read these instructions thoroughly and retain for future use e All products manufactured and supplied by Bristan are safe provided they are installed used correctly and receive regular maintenance in accordance with these instructions e If you are in any doubt about your ability to install this product safely you must employ the services of an experienced qualified plumber electrically qualified person AN Warning Do not operate the shower unit if you suspect it is frozen Do not site the shower unit where it might be subjected to freezing conditions e Do not install this shower unit in a room environment without adequate ventilation or an extractor fitted This is required to prevent condensation forming within the unit e Do not operate the shower unit if the showerhead or spray hose has been damaged or is blocked e Do not block the flow of water from the showerhead by placing it smothering it on your hand or any other part of your body or oreign object e Do not operate the shower if the wate
6. against the elbow and pull Rar 4 he blanking plug out of elbow VN he elbow p Please note Some water Pull blanking Collet plug from elbow rom factory testing may escape Connect the mains water supply to the inlet port of the shower using 15mm copper pipe BS EN1057 or 15mm plastic pipe with insert Do not use stainless steel pipe work If using chrome plated pipe ensure that the first 25mm of plating is carefully removed to allow push fit fitting to grip the inlet pipe Inlet Entry Options The pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as shown on page 9 To top or bottom left positions The shower unit should come supplied with the inlet connection set for a bottom left position To change it to a top left position swivel the inlet connector elbow from facing downward to facing upward To bottom right position Unfasten the screw 7 securing the inlet connector elbow clamp 8 remove the tab from the slot and keep until the inlet pipe is repositioned Lift the outlet connection 9 up out of the way from its position at the bottom of the unit Pull the inlet connector elbow towards you and over to the right hand side with the inlet entry point facing down Refit the clamp tab 8 into the slot on the right refasten the screw 7 and
7. and operated in accordance with our instructions and has not been misused or damaged Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Service Policy Replacement Parts Policy Important In the event of product or component malfunction DO NOT tamper with or remove the product from site Telephone the Customer Services Department and be prepared with the date of purchase model number and a clear description of the complaint Our service staff are fully qualified to advise on correct installation procedures and will be able to diagnose whether the fault will require a replacement part or a visit from a Bristan engineer If required a service call will be booked and either yourself or an appointed representative who should be a person of 18 years or over must be present during the visit All site visits to product within the guarantee period will be carried out free of any parts or labour charges provided the conditions of the guarantee have been adhered to the second year guarantee is parts only All site visits to product out of guarantee will be subject to charges for parts and labour Charges will also be levied on cancelled appointments unless advised to Bristan at least 24 hours in advance of the agreed date and time Should a product be discontinued spare parts stocks will be maintained but in
8. be a type AUK not less than 20mm or twice the diameter of the inlet pipe to the fitting whichever is the greater Pressure Relief Device PRD A pressure relief device is designed into this shower The pressure relief device provides protection should an excessive build up of pressure occur within the shower unit It is advisable to position he shower unit over a bath or shower tray in the unlikely event the device should discharge Do not use the shower with a damaged or kinked shower hose or blocked handset This may trigger the PRD which will discharge hrough the vent in the bottom right hand corner shown n the event of the PRD activating water will be discharged from the vent If this happens switch off the electricity and water supplies to he shower and contact Customer Services see page 19 Double switc pole Hose _ retainer Bath spillover Shower unit 1m minimum height from shower unit to floor capi i level Shower tray ___ spillover level L Minimum 20mm between showerhead and spillover PRD Vent Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Fixing Your Shower to the Wall Remove A Warning Please check for any hidden pipes and cables before B covers
9. can result in the cables overheating ensure all terminal screws are fully tightened The supply cable earth conductor must be sleeved The supply cable must be secured by routing through conduit or in trunking or by being embedded in the wall in accordance with current E E Regulations A Warning Do not switch on power to the shower unit until the cover has been fully fitted e Plug in the cable from the cover to the connection 10 inside the unit e Rotate the temperature control knob 6 fully clockwise full hot e Rotate the splined temperature control spindle 6a fully clockwise e Locate cover in position ensuring wiring is not trapped Note slight adjustment of the knob may be required to locate cover correctly e Secure using the 4 cover fixing screws supplied Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors 13 Fixing Your Riser Rail to the Wall Fitting the Riser Rail Before proceeding with fitting the rail identify each of the items supplied using the illustration on the right The Slider should not be removed from the rail during fitting The underside of the slider has a button to release the slider and allows the height to be ad
10. replace the outlet connection 9 To rear entry positions Swivel the inlet connector elbow to face a rear entry pipe connection If the pipe work entry is from the rear ensure that there is space left around the push fit elbow for future servicing or alternatively access is possible from the rear Bring the cold water pipe to the shower position and connect to the inlet elbow L E Sy Outlet connection 9 Inlet connector elbow right side down or rear 10 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Plumbing Connections cont Hole Cover Fitting Top left entry Depending on your choice of cold water entry direction you may need to remove thin areas of plastic cover to facilitate pipe work entry down through the top left of the unit Bottom entry Depending on your choice of cold water entry direction fit hole covers to the pipe work slots at the bottom of the unit Note The grey areas shown are tabs that can be removed to allow 6mm cable entry only Water Connection The inlet pipe connection into the elbow is a self seal push fit type All burrs and rough edges must be removed from the end of the pipe before connecting To release the pipe work from the push fit type fitting press and hold the collet against the elbow and pull the pipe out of the elbow Turn on the water supply and inspect for water l
11. the event of a part becoming unavailable Bristan reserve the right to supply a substitute of equal quality For spare parts please contact Customer Services or via the Bristan website Opening times Please refer to the Bristan website Customer Service Tel 0844 7016273 s Fax 0844 7016275 E mail enquirefdbristan com Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors 19 Spare Parts BRISTAN bliss HH No Part No Description Parts List Quantity 01 31 140 S Stabiliser Valve Ass Stabiliser Valve x1 inc O rings x3 02 31 209 Auxiliary Microswitch Auxiliary Microswitch x1 03 31 300 8 5 Heat Exchange Unit Ass 8 5 kW Heat Exchange Unit 8 5 kW x1 Metal Clip x1 inc O rings x2 03 31 300 9 5 Heat Exchange Unit Ass 9 5 kW Heat Exchange Unit 9 5 kW x1 Metal Clip x1 inc O rings x2 03 31 300 10 5 Heat Exchange Unit Ass 10 5 kW Heat Exchange Unit 10 5 kW x1 Metal Clip x1 inc O rings x2 04 31 307 S Thermal Cut Out Ass Thermal Cut Out x1 inc Screws x2 05 31 315 S 2 Outlet Pipe Ass with hole Outlet Pipe x1 Metal Clip x1 inc O ring x1 06 31 309 S Pressur
12. 5kW 10mm The Electrical Installation and Circuit Protection of this shower must comply with current I E E Wiring Regulations and should be installed by a qualified electrician prior to use Important You must switch off the power at the consumer unit isolate the electrical circuit and verify the earth before making any electrical connections The shower must only be connected to a 230 240V AC supply The electrical rating of your shower is on the pack or on the rating plate label The shower must be connected to its own independent electrical supply It must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse box is below 80A you should seek advice from an electrician and may need a new consumer unit specifically for the shower A separate and permanently connected cable must be taken from the consumer unit directly to the shower via a double pole switch with a minimum contact separation gap of 3mm in live lU and neutral N poles Note Voltage drop in the supply to the premises due to heavy local demand will affect the performance of your shower To gain the optimum power possible from this shower unit try to find the shortest possible route from the consumer unit to the shower to run your cable continued on next page 30mA RCD For ampage Shower unit
13. BRISTAN Installation Instructions and User Guide Bliss Electric Showers BRISTAN bliss Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them with the user Contents Welcome to your new Bristan electric shower Featuring a contemporary design with lots of fun features Bristan s electric shower collection has been designed to be enjoyable to fit and to use It has also been designed and tested in the UK to all of the relevant British Standards These instructions contain all of the necessary installation and operating information so please read them thoroughly and keep for future reference These instructions are for your guidance to a safe and successful installation which must be carried out by a suitably qualified person and conform with current I E E Regulations Note An Installation Template is provided in the centre pages of this booklet Important Safety Information esenensiasenensiarssa 3 Product II ee ea 4 Electrical Requirements aaa Saravan avar ayan anava 879 7o 9379 5 6 Water Requirement cccccccecceeceeseeeeeeesetetetteetneeteeees 7 Fixing Your Shower to the Wall sst gt ashen 8 PLUMBING CONMECHONS a aa E 91 S737171 T B aa 9 11 Electrical COMMECtONS adonna ET Hanania 0 2 13 Fitting Your Riser Rail to the Nal 14 Commissioning Testing the System 5 Operating the SHOWED sasesana sa isai 6
14. Bracket Ass Wall Brackets x2 Wall Bracket End Caps x2 Screws x2 Wall Plugs x2 03 207179 Riser Rail Ass Riser Rail x1 Riser Rail End Caps x2 04 1932A0A Slider Handset Holder Slider Handset Holder x1 05 11047A0A Soap Dish Soap Dish x1 06 55023 Handset Handset x1 07 37 3428 1 5001 3R Hose Ass Hose x1 Rubber Washers x2 22 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors 23 Issue FI ES Bliss A Part Number 131 724 BRISTAN Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire dbristan com A Masco Company
15. crews drilling holes in the wall Remove the 4 cover retaining screws and lift off the cover Do not try to remove the control knob from the cover It is an integral part of the cover and must not be removed If you are fitting the unit to a partition wall or a wall of particularly friable crumbly substrate you will need appropriate fixings for the wall type Select the position for the shower unit over a bath or shower tray using the installation template provided in the centre pages of this booklet Important The shower unit must be fitted to a flat waterproof surface Under no circumstances should the shower unit be attached to a wall and then tiled up to the edges The unit must be fixed on top of the wall surface Important Use a spirit level to ensure the template is level Mark the 3 fixing points with a suitable pencil through the paper Remove the template from the wall and drill the wall to suit the wall fixings to be used Tips f Wall fixing points A piece of insulation or masking tape positioned where holes m J are to be drilled and before marking out the exact position for the fixing holes will help stop the drill bit from wandering particularly on a tiled surface When working near a basin bath or shower insert plug or cover waste to prevent losing small parts Take care not to drop tools equipment into basin bath or shower during shower installation
16. d physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Important Children should be supervised to ensure that they do not play with the appliance Important The shower unit must be switched off at the isolating switch pull cord when not in use Operating the Controls Power Control ws Control Q 2 NO Heater Elements ON NO Heater Elements ON 1 Heater Element ON 2 Heater Elements ON OFF COLD Water Medium Temperature Water HOT Water HOT reduced flow COLD increased flow 16 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Operating the Shower cont Adjusting the Showerhead Your Bliss showerhead has 3 spray modes spray jet spray and combination Simply rotate the spray head one way or the other to the desired spray pattern Note The spray head mode may need to be altered during winter conditions low flow conditions to achieve a satisfactory spray Jet spray Combination Maintenance General Cleaning Before attempting to clean your shower unit you must switch off the power at the isolating switch Do not remove the cover Do not use abrasive cleaners or solvents to clean this unit The shower unit and acce
17. e Relief Diaphragm Housing Ass Pressure Relief Diaphragm Housing x1 inc Screws x2 07 31 308 Pressure Relief Diaphragm Pressure Relief Diaphragm x1 08 31 400 S Water Inlet Ass Inlet Elbow x1 Swivel Inlet Pipe x1 Filter x1 inc O rings x3 09 31 406 S nlet Elbow Ass Inlet Elbow x1 inc O ring x1 0 31 404 S Filter Ass Filter x1 inc O ring x1 1 31 402 S Swivel Inlet Pipe Ass Swivel Inlet Pipe x1 inc O ring x1 2 31 401 nlet Pipe Clamp Inlet Pipe Clamp x1 2 3 31 516 BLISS W Bliss Front Cover WHITE White Front Cover x1 3 31 516 BLISS B Bliss Front Cover BLACK Black Front Cover x1 4 31 500 S Control Dial Ass Control Dial x1 Dial Drive x1 inc O ring x1 and Screw x1 5 31 600 S W Fixing Kit Ass WHITE Full Shields x2 Half Shield x1 Wall Screws x3 Wall plugs x3 Cover Screws x4 5 31 600 S B Fixing Kit Ass BLACK Full Shields x2 Half Shield x1 Wall Screws x3 Wall plugs x3 Cover Screws x4 6 31 607 Wire Terminal Mains Terminal Block x1 yi 31 501 Rubber Seal Front Cover Seal x1 20 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Spare Parts 17 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors 21 Spare Parts cont 01 03 02 03 04 s 1 9 02 01 03 No Part No Description Parts List Quantity 01 1578A0A Riser Rail End Cap Riser Rail End Cap x1 2 02 1576A0A Wall
18. eaks at the shower inlet Once inspected turn off the water supply Back of uni Q cover Pipe cover Blanking NETS Pull collet E back towards Ole elbow Pull pipe from elbow Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors joss Collet Electrical Connections A Warning This appliance and all connecting metal pipe work must be earthed e Ensure that an earth continuity conductor is securely and permanently connected to all exposed metal parts of other services and appliances within the room where the shower Is installed e All cables must conform to the relevant tables within the current LEE Regulations The electrical supply cable must be either recessed or in a conduit trunking as detailed in the current E E Regulations Refer to pages 5 and 6 Electrical Connection Entry Point Options Select the cable inlet option most suited to your situation
19. eed help Give us a call on 0844 701 6273 and speak to one of our trained advisors Operating the Shower Please ensure the commissioning procedure has been carried out If you did not fit this shower yourself and you are about to use it for the first time check with the installer to ensure he or she has run the commissioning procedure as described on page 10 To Start the Shower Press the STOP START touch button 3 Note The display will only light up once the STOP START touch button is pressed then the temperature indicator display will start to count up During periods of high ambient temperatures e g hot summer days it may be necessary to select a lower power setting in order to achieve your ideal shower temperature To Stop the Shower Press the STOP START touch button 3 Phased Shut Down When the shower is turned off water will continue to flow for a short period of time while the heater cools down This ensures that the shower is ready for the next user Do not use the isolation switch pull cord to stop the shower use the STOP START touch button 3 It is always advisable to test the water temperature with your hand before stepping under the shower Please note that there is always a delay of a few seconds between you selecting a temperature setting and the selected water temperature starting to flow A Warning This appliance is not intended for use by persons including children with reduce
20. gt L dR F SE S S le x J 4 Rear right inlet entry Rear left inlet entry requiring rear access Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors requiring rear access Top left inlet entry a J e ia o je 6 i o D CLO fi N S L d L LD ka Rear left inlet entry using a 19mm compression elbow not supplied Plumbing Connections cont A Warning The outlet of the shower acts as a vent and must not be blocked restricted or connected to any tap closure device other than the handset supplied Do not solder within 300mm of the shower unit or allow solder or flux to fall onto the casings Important An additional independent stop valve complying with the current water regulations must be fitted in the mains water supply as a means of isolating the supply to the unit for servicing and or maintenance work It is essential that all pipe work is flushed through to remove debris and swarf that could otherwise damage the unit Once the pipe work has been flushed through turn off the water supply at the stop valve Remove the blanking plug rom the inlet connector elbow f J Press and hold the collet Li E
21. hole in the wall or over a tile joint Remove the lower bracket from the rail and unscrew the upper bracket from the wall Mark and drill the lower wall bracket fixing position and fix the bracket to the wall Slide the rail down through the lower wall bracket and reattach the upper bracket Check that the rail is perfectly vertical and tighten the upper fixing screw Insert end caps into the wall brackets at both ends of the rail When fitting the hose it should pass through the larger hole of the soap dish Note The conical hose end and not the handset handle fits into the slider The slider moves more freely on the rail if gripped next to the rail rather than at the handset Slider release Ea button Hose Accessory hooks Conical e hose end L 14 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Commissioning Testing the System A Warning Before using the shower for the first time it should receive a final flush through to remove any remaining debris that BRISTAN bliss may be in the pipe work or hose and to ensure the heater unit contains water before the electrical elements are switched on Remove the showerhead from the hose and if not already attached attach the hose to the outlet port The temperature control knob 6 must be set fully clockwise to minimum flow This is to prevent the PRD activating when water is first turned on
22. hooting Symptom Likely Cause s Action Remedy No water flow Water isolating valve in off position Filter blocked Power supply not on Turn on Turn off water supply remove filter and clean Turn on Water temperature too hot Insufficient water flowing through the shower Clean the handset Increase the flow by adjusting the temperature control knob to cooler setting Reduce the power setting during use Shower runs hot and cold Water pressure is at minimum requirement Check running pressure minimum of 0 7bar Wait until pressure increases Shower temperature cycles Shower temperature is set too high causing between hot and cold the thermal cut out to turn off the heating elements to reduce the water temperature Turn shower temperature control anti clockwise to reduce the water temperature Call Customer Services Water from pressure relief Obstruction in hose or handset outlet PRD activated LOW PRESSURE appear Low Pressure water supply to shower unit in temperature indicator display Low water flow through shower handset Turn off unit and wait until water pressure increases before using again Increase water flow rate by turning temperature control to cooler setting 18 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Guarantee Guarantee Thank you for purchasing a Bri
23. justed Slide the soap dish onto the bottom end of the rail Position a wall bracket onto each end of the rail ensuring the hole through the top of the rail lines up with the hole in a wall bracket Position the rail on the wall bearing in mind the different heights of people likely to use the shower and the length of the hose when connected to the shower and passed through the retaining hole in the soap dish Mark the wall to indicate the upper fixing screw position A Warning Please check for any hidden pipes and cables before drilling holes in the wall Tips A piece of insulation or masking tape positioned where holes are to be drilled and before marking out the exact position for the fixing holes will help stop the drill bit from wandering particularly on a tiled surface When working near a basin bath or shower insert plug or cover waste to prevent losing small parts Take care not to drop tools equipment into basin bath or shower during shower installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the side shown and wall bracket Check that the rail is hanging vertically using a spirit level Slide the lower wall bracket onto the rail and mark its required position onto the wall Note The lower wall bracket does not fix to the riser tube and can be positioned along the riser tube so as to cover either an existing riser
24. lay is an indication of the water temperature Inside the unit not the outlet water temperature Any slight up or down fluctuations on the display during use are normal 2 Medium eco Power Touch Button 3 STOP START Touch Button 4 Cold 26 Power Touch Button 5 High Power Touch Button 6 Temperature Control Adjustable temperature control Note When Power Touch Buttons 2 4 and 5 are selected the appropriate icon will illuminate below the temperature Indication Temperature Control Device The Temperature Control Device will activate when the temperature is set too high and the water inside the water heater gets too hot The Temperature Control Device will switch off the power to the heating elements Once the unit cools down to a safe temperature the elements will come on again and reheat the water within the water heater and the whole cycle will repeat itself until the temperature is manually reduced Phased Shut Down When the shower is turned off water will continue to flow for a short period of time while the heater cools down to approximately 30 on the display before automatically turning off 4 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Electrical Requirements A Warning This appliance MUST be earthed Isolating valve Double pole switch Rating at 240V Rating at 230V Cable Size 8 5kW 7 8kW 6mm 9 5kW 8 7kW 10mm 10 5kW 9
25. on derating factors Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Water Requirements The installation must comply with all Water and Building Regulations England and Water By laws Scotland If the shower is to be installed in a hard water area we recommend that an in line scale inhibitor is fitted which will prolong the life of the shower Please refer to your supplier for advice A Warning The shower must not be installed in an area subject to freezing conditions Do not use if you suspect the shower is frozen this will damage the shower unit The shower must be connected to a mains water supply only with a minimum working inlet pressure of 0 07MPa 0 7bar at a minimum flow rate of 8 litres per minute The maximum static inlet pressure must not exceed 1 0MPa 10bar If it is intended to operate the shower at pressures above the maximum stated a suitable pressure reducing valve PRV should be used Water regulations stipulate that the showerhead be constrained by a fixed or sliding attachment hose retainer so that it can only discharge water at a point not less than 20mm above the spill over level of the bath or shower tray or other fixed appliance If a showerhead can sit within a bath basin or shower tray you must fit a double check valve in the supply pipe work to prevent back siphonage If the showerhead can sit within a WC then the air gap should
26. r stops flowing during use or if the water is leaking from the shower unit itself Turn off at the mains electrical supply and refer to the Troubleshooting section see page 18 or contact Bristan Customer Services see page 19 e Do not crush or kink the shower hose this could damage the hose cause leaks and activate the pressure relief device PRD General Safety e Always switch off the power at the consumer unit and Isolate the electrical supply before making any electrical connections or if you have to remove the cover of an installed unit The unit must be mounted on the finished wall surface usually tiled Under no circumstances must you tile up to or seal around the unit as this may prevent air circulating and condensation escaping e This shower unit must not be modified in any way as this will invalidate the guarantee Except for top left pipe entry see page 9 where the product has been designed to be modified by the installer BEAB Approved BEAB British Electrotechnical Approvals Board approval of safety Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Product Features 1 Temperature Indication Water temperature indication display The display will only light up once the STOP START touch button is pressed then the temperature display will start to count up depending on the position of control 6 Note The digital disp
27. ssories should be cleaned with a soft clean damp cloth Bristan recommend E cloth for cleaning all of our bathroom and Kitchen products Using just water E cloth gives smear free deep clean by breaking up and holding dirt which normal cloths leave behind Order through your Bristan stockist Order code Ecloth Cleaning the Showerhead Your Bristan showerhead has a rub clean pad for easy cleaning Simply rub your fingers across the rubber spray jets regularly and before you turn the shower on to remove any scale or debris The hardness of the water in your area will determine how often you should clean your showerhead Build up of scale in particularly hard water areas combined with constant use means you may need to clean your showerhead once a week To ensure continued performance of your electric shower the showerhead needs to be regularly descaled continued on next page Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors Maintenance cont Cleaning the Filter Periodically remove the inlet filter and rinse under clean running water First isolate the electrical and water supply to the unit To remove Turn anti clockwise using a large flatblade screwdriver Note A small amount of water will be discharged when the filter is removed this is normal To clean Wash under clean running water Refit the filter and gently tighten S OOO Troubles
28. stan product This product has been designed and tested in the UK to the highest standards Guarantee 2 Year parts 1 Year labour subject to registration This guarantee applies to products purchased within the United Kingdom or Republic of Ireland but does not apply to products used commercially This is provided that The guarantee registration card is completed and returned within ten days complete with a copy of proof of purchase Proof of purchase is required for any servicing requirements 2 The product is installed and operated in accordance with our instructions and has not been misused or damaged This in no way affects your statutory rights as a consumer The information on the Guarantee card helps Bristan to process any claims and contact you about your product and its maintenance if required The registration of your personal details is purely for Bristan use and the remaining information helps us to make products for the future Should a complaint arise products are guaranteed against faulty workmanship and materials for a period of 12 months from the date of purchase when in domestic use second year guarantee is parts only For your guarantee to be valid your shower must be installed by a competent person in accordance with the instruction manual Bristan will repair or replace at our option free of charge any faulty components during the guarantee period provided it has been maintained
Download Pdf Manuals
Related Search
Related Contents
Gainward 426018336-3392 NVIDIA GeForce GTX 960 2GB graphics card DoubleBed™ Trampoline User`s Manual UM SA-80 - Suisse Daray VISION100 Digital Microscope Mogul User Guide and Tutorials 2010 CSDS Release Moniteur de chevet portable Capnographe/Oxymètre de pouls Multi-Mixer mit Kochfunktion VME Interface VC16 User Manual - W-IE-NE Salmonella Real Time PCR Kit User Manual For In Vitro Diagnostic Copyright © All rights reserved.