User Guide Refrigerant Leakage Detector

image

Contents

1. HCFCs and HFCs Sensor Heated Diode Sensitivity Levels High 0 250z yr 7g yr Medium 0 502 yr 14g yr Low 0 990z yr 28g yr Warm up Time 90 seconds Auto Power OFF Automatic shut off after 10 minutes Low Battery Indication LOW BATT light switches ON Power Supply 9V Battery Battery Life 13 hours of continuous use Operating Conditions 0 C to 50 C 32 F to 122 F lt 80 RH Storage Conditions 10 C to 60 C 14 F to 140 F lt 70 RH Flexible Probe Length 450mm 18 Dimensions Weight 184 x 70 x 40 mm 7 2 x 2 8 x 1 6 Weight 280g 10 0 oz Copyright 2013 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form www extech com 6 RD300 EU EN V1 1 12 13
2. Set the raised point in the same side Notes 1 The life of the sensor is 1 year under normal use if a sensor is exposed to a 100 ppm refrigerant the sensitivity characteristics of the sensor may be affected 2 Make sure there are no water droplets or dust on the surface of the sensor 4 RD300 EU EN V1 1 12 13 Maintenance Cleaning 1 Wipe the meter housing with a damp sponge or soft cloth Use only mild soap and water 2 Never use organic solvents to clean the meter such as thinner benzene etc as they can damage the sensor Battery Replacement When the low battery LED is lit the 9V battery must be replaced 1 The battery compartment is located on the rear of the meter 2 Open the rear battery cover and replace the battery 3 Make sure the battery cover is snapped into place securely before operating the meter Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever mm batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment 5 RD300 EU EN V1 1 12 13 Specifications General Specifications Detectable Refrigerants R 22 R 134a R 404a R 410a and all CFCs
3. The detector will automatically start heating the sensor after power on During the 90 second warm up the Leak Level LEDs and Power LED will be lit in cyclic fashion and the meter After the warm up the audible tone will sound and the Power LED will remain lit At this time the detector is ready to find leaks Sensitivity Range Button Press the Sensitivity Range button to change sensitivity levels The High medium or low LED will light depending upon the user s selection The detector will automatically default to the previous sensitivity level after warm up Reset Button Press the R button once to reset the meter the reset LED will flash once Mute button Press the Mute button to toggle the audio on and off The mute LED is on when the audio is switched OFF muted Tip Work Light LED Button Press tip light LED button to switch the probe tip work light ON or OFF Pass the sensor tip near the potential source of leak and gage the meter s response by observing the color coded LEDs Green LEDs represent the absence of a leak or a very small leak yellow LEDs represent a moderate leak and red LEDs represent the detection of a large leak Probe and LED Work Light Replacement To replace the 3V LED work light or the sensor please refer to the diagram below Please switch off the detector before removing sensor Diode sensor tip part number RD300 S LED work light part number RD300 L Light LED Protector Sensor
4. EXTECH User Guide INSTRUMENTS Refrigerant Leakage Detector Model RD300 Safety Please read the following safety information carefully before attempting to operate or service the meter Only qualified personnel should attempt repairs Safety symbols C CE Certification This instrument complies with the following standards EN61326 Electrical equipment for measurement control and laboratory use equipment EMC test IEC61000 4 2 ESD immunity test IEC61000 4 3 Radiated radio frequency electromagnetic field immunity test IEC61000 4 8 Power frequency magnetic field immunity test Be sure to follow the safety points below Failure to do so could cause personal injury or damage to the meter e Please read this manual carefully to ensure safe and correct use of this meter before using e Do not attempt to repair this device only qualified personnel should repair this device e Do not force the flexible tube to bend over its angle limit Doing so can damage the device e Do not subject the probe tip to shock or severe vibration e Do not use this device near fire or in flammable explosive environments e Do not use this device in ambient conditions outside of the following limits 0 C to 50 C 32 to 122 F e Never use organic solvents to clean the meter 2 RD300 EU EN V1 1 12 13 Introduction Congratulations on your purchase of the Extech RD300 Leakage Detector This handheld meter measures leakag
5. e from air conditioning or cooling systems that use refrigerant The LED work lights allow for viewing in dark or dimly lit environments This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Features e Detects all existing refrigerants using a heated diode sensor e LED work lights with on off switch to allow viewing in dark environments e High Medium Low color coded LED indication with sensitivity of 0 25 oz year e Audible and visual alerts with mute button e Low battery indication e Field replacement sensor and LED work light tip Meter Description 1 ON OFF button hold for 2 seconds 2 Color coded LED Level Indicators bottom LED indicates power on 3 Reset button 4 LED work light on off button 5 Probe tip sensor 6 LED work light 7 Sensitivity Range select button 1 8 Mute sound button 9 Loudspeaker yn 10 Low battery Mute and Reset status lights 11 High Med and Low sensitivity indicators 12 Flexible probe 3 RD300 EU EN V1 1 12 13 Operation 1 Power Button Press and hold the power button for 2 seconds to turn power ON All LEDs will light and the start up tone will sound Press and hold power button for 2 seconds to turn off the meter Check the battery if the meter does not switch ON Warm Up