        InstallatIon & User GUIde thermostatIc mIxers mIra
         Contents
1.        SHOWERS                         MIRA INFUSE  amp  MIRA MINIBELLE  THERMOSTATIC MIXERS  INSTALLATION  amp  USER GUIDE                      These instructions must be left with the user           CONTENTS             INTRODUCTION          Introduction  Patents  Safety Warnings  Pack Contents  Specifications  Pressures  Temperatures  Thermostatic Shut down  Connections  Dimensions  Installation  Suitable Plumbing Systems  General  Flow Regulator  Installing the Thermostatic Mixer  Commissioning  Maximum Temperature Setting  Operation  Temperature Control  Flow Control  User Maintenance  Fault Diagnosis  Lubricants  Cleaning  Spare Parts  Customer Service    oOo o Oo oc OonaMonan A FP PHP HR PWOWN DN         Oo    10  10  10  11    Back Page       If you experience any difficulty with the  installation or operation of your new  thermostatic mixer  please refer to    Fault  Diagnosis     before contacting Kohler Mira Ltd   Our telephone and fax numbers can be found    on the back cover of this guide           Thank you for purchasing a quality Mira product  To  enjoy the full potential of your new product  please  take time to read this guide thoroughly  having  done so  keep it handy for future reference     The Mira Infuse and Mira Minibelle are thermostatic  mixers which have separate flow and temperature  controls  They are supplied complete with Mira  L98B Shower Fittings     The thermostatic mixers incorporate a wax  capsule temperature sensing unit  which provides  a
2.   C hot and nominally equal pressures      9 Recommended Hot Supply  60  C to 65  C  Note  The mixing valve can operate at  higher temperatures for short periods without  damage  however this could detrimentally  affect thermostatic performance  For safety  and performance reasons it is recommended  that the maximum hot water temperature is  limited to 65  C        Cold Water Range  up to 25  C     Minimum Recommended Differential between  Hot Supply and Outlet Temperature  12  C     Thermostatic Shut down    For safety and comfort the thermostat will  shut off the mixing valve within 2 Seconds if  either supply fails   achieved only if the blend  temperature has a minimum differential of  12  C from either supply temperature      Connections    The thermostatic mixer can only be installed with   rear supply inlets and the supply pipework must   be connected as follows    9 Hot  Bottom  side nearest flow control    15 mm compression     Cold  Top  side nearest temperature control    15 mm compression     9 Outlet       BSP Male to flexible hose     Note  This product does not allow for reversed  inlets and will deliver unstable temperatures if  fitted incorrectly     Dimensions     42                                                   _ 047    All dimensions in mm                                                    174             INSTALLATION  Suitable Plumbing Systems          Gravity Fed    The thermostatic mixer must be fed from a cold  water cistern  usually fitted in the 
3.   The chrome plated parts should be cleaned using  a mild washing up detergent or soap solution   rinsed and then wiped dry with a soft cloth   Warning  Many household cleaners contain  abrasive and chemical substances  and should not  be used for cleaning plated or plastic fittings   These finishes should be cleaned with a mild  washing up detergent or soap solution  and then  wiped dry using a soft cloth    Use your thumb or a soft cloth to wipe any  limescale from the soft nozzles and the front  surface of the handset spray plate    Do not use descalents on this product              SPARE PARTS       1660 156  Temperature Knob  Pack  Infuse     1660 155  Temperature Knob  Pack  Minibelle     1660 150    Backplate  1660 151 CD  Concealing Plate CO  SST    1660 152  Filter Pack  x2                            1660 158  Flow Knob Pack  Infuse    also includes Securing Nut         1660 153  Inlet Nuts  amp  Olives  x2   1660 157   Flow Knob Pack  Minibelle    also includes Securing Nut     1660 154  Mixer Valve Assembly    1663 213  12 L Min Flow Regulator    Not illustrated   1660 159 Screw Pack  1660 175 Seal Pack             1660 168 1660 169  Outlet Shroud and Outlet Shroud and  Securing Nut  Minibelle  Securing Nut  Infuse     11       CUSTOMER SERVICE  Guarantee of Quality    Mira Showers guarantee your product against any defect  in materials or workmanship for the period shown in the  Guarantee Registration Document included with your  shower    Alternatively  to confir
4.  manual to see whether simple home maintenance is  required  Please call our Customer Services Team to talk  the difficulty through  request a service under guarantee  if applicable  or take advantage of our comprehensive  After Sales service    As part of our quality and training programme calls may be  recorded or monitored    Our Customer Services Team is comprehensively trained to  provide every assistance you may need  help and advice   spare parts or a service visit     5 013181 038330 gt     1084102 W2 A  B94E   1663              Mira is a registered trade mark of  Kohler Mira Limited     The company reserves the right to alter  product specifications without notice   www mirashowers com    Spare Parts   We maintain an extensive stock of spares and aim to provide  support throughout the product s expected life    Spares can be purchased from approved stockists or  merchants  locations on request  or direct from Customer  Services    Spares direct will normally be despatched within two working  days  Payment can be made by Visa or MasterCard at the  time of ordering  Should payment by cheque be preferred   a pro forma invoice will be sent    All spares are guaranteed for 12 months from date of  purchase  Spares that have been supplied directly form us  can be returned within one month from date of purchase   providing that they are in good order and the packaging  is unopened    Note  Returned spares will be subject to a 15  restocking  charge and authorisation must be 
5.  suitable position for the Mixer   The position of the Mixer and the Shower  Fittings must provide a minimum gap of 25 mm  between the spill over level of the shower  tray bath and the handset  refer to illustration    This is to prevent back siphonage  For further  information on the installation of your Shower  Fittings  refer to the Fittings Installation and  User Guide    Note  Only use Shower Fittings recommended  by the manufacturer or supplier     O                                           25 mm  Spill Over  Level             Flow Regulator    Site conditions will determine the flow regulator  requirements    For gravity fed   other low pressure systems   0 5 bar or below  remove the outlet flow  regulator     Outlet Flow  Regulator       Hose  Washer    Installing the Thermostatic Mixer    1     The thermostatic mixer must be fitted vertically  as illustrated and can only be installed with  rear supply inlets  The supply pipework must  be connected as follows      Hot to Bottom Inlet      Cold to Top Inlet     Bottom Outlet    Important  This product does not allow for  reversed inlets       Determine the route for the hot and cold supply    pipework           Outlet      Loosen the 2 backplate grubscrews with    the 2 mm hexagon key  supplied  and pull  the mixer and concealing plate from the  backplate       Unscrew the inlet nuts from the backplate     Backplate        Concealing Plate  Inlet Nuts          6  Using the backplate as a guide  mark the    positions o
6. e   i e  fully anticlockwise  and allow the  temperature to stabilise    2  Test that the temperature of the water from the  shower outlet is hot enough   If the temperature is too hot or too cold adjust  as follows    3  Carefully remove the concealing cap using a  suitable tool  i e  stanley knife   thin blade     4  Unscrew the securing screw and remove the  temperature lever bearing    5  Lift the temperature lever and move it back one  serration on the temperature control gear    6  Return the lever to the maximum temperature  stop and check the temperature  if it is still not  hot enough repeat the procedure     Stanley Knife   Concealing Cap    Thin Blade   Cc Rubber Seal   Ss   A YZ Lift the temperature lever   a and move back one serration  SN    Temperature  Lever  Bearing    Securing  Screw         Re engage with the control  gear and return to the  maximum temperature stop    7  Once the maximum temperature is satisfactory   refit the temperature control bearing and fit and  tighten the securing screw    8  Refit the concealing cap  make sure that the  rubber seal is correctly fitted           Caution  Care is required when adjusting flow  or adjusting temperature  Make sure that the  temperature has stabilised     The thermostatic mixers have separate control  levers for temperature and flow     Temperature Control    Turn the temperature control lever clockwise to  decrease the temperature and anticlockwise to  the preset maximum temperature    Off       Flow Co
7. f the fixing holes and the pipe  centres    Note  Make sure that the backplate is the  correct way up  refer to illustration            Large boss must be  fitted at the bottom          LOAL                7  For solid walls drill the fixing holes for the  backplate with a 6 mm drill and insert the  wall plugs  supplied   For other types of wall  structure alternative fixings may be required   not supplied     8  Drill the holes for the supply pipes and fit the  supply pipework    Hot to Bottom Inlet  Cold to Top Inlet   Note  The inlet pipework should extend  between 12 and 18 mm from the finished wall  surface    Caution  Make sure that the pipework is not  damaged otherwise the olives will not seal    9  Fit the backplate over the inlet pipes and  secure to the wall using the fixing screws   supplied    Note  Make sure that the backplate is the  correct way up  refer to illustration     10 Caution  It is essential at this point  that the supply pipework is thoroughly  flushed through before connection to the  mixer  Failure to do so may result in product  malfunction and will not be covered under the  guarantee    11 Fit the olives onto the inlet pipework and tighten  the inlet nuts using a suitable spanner   Caution  Do not overtighten    Important  Make sure that the inlet filters are  fitted in the inlet nuts as illustrated     Fixing Screws          Large boss must be  fitted at the bottom    12 Make sure that the concealing plate  with    the hole at the bottom  is lo
8. loft space  and  a hot water cylinder  usually fitted in the airing  cupboard  providing nominally equal pressures     Mains Pressurised Instantaneous Hot Water  System  Combination Boiler      The thermostatic mixer can be installed with  systems of this type with balanced pressures    Recommended Minimum Maintained Pressure   1 0 Bar      Unvented Mains Pressure System     The thermostatic mixer can be installed with an  unvented  stored hot water system     Pumped System     The thermostatic mixer can be installed with an  inlet pump  twin impeller   The pump must be  installed in a suitable location and in accordance  with its instructions     General    Installation must be carried out in accordance  with these instructions  and must be conducted by  designated  qualified and competent personnel   The installation must comply with the    Water  Supply Regulations 1999  Water Fittings     or any  particular regulations and practices  specified by  the local water company or water undertakers   Note  Make sure that all site requirements  correspond to the information given in section      Specifications        1  The Mixer must not be installed in an area  where it may freeze    2  For stud partitions alternative fixings may be  required    3  Isolating valves must be installed close to the  Mixer for ease of maintenance    4  Pipework must be rigidly supported and avoid  any strain on the connections    5  Pipework dead legs should be kept to a  minimum     6  Decide on a
9. m the applicable guarantee period  please contact Customer Services    To validate the guarantee  please return your completed  registration card    Within the guarantee period we will resolve defects  free  of charge  by repairing or replacing parts or modules as  we may choose    To be free of charge  service work must only be undertaken  by Mira Showers or our approved agents    Service under this guarantee does not affect the expiry  date    The guarantee on any exchanged parts or product ends  when the normal product guarantee period expires    Not covered by this guarantee    Damage or defects arising from incorrect installation   improper use or lack of maintenance  including build up  of limescale    Damage or defects if the productis taken apart  repaired or  modified by any persons not authorised by Mira Showers  or our approved agents    This guarantee is in addition to your statutory and other  legal rights     What to do if something goes wrong  If when you first use your shower  it doesn   t function  correctly  first contact your installer to check that installation  and commissioning are satisfactory and in accordance with  the instructions in this manual  We are on hand to offer you  or your installer any advice you may need    Should this not resolve the difficulty  simply contact our  Customer Services Team who will give every assistance  and  if necessary  arrange for our service engineer to  visit  If the performance of your shower declines  consult  this
10. n almost immediate response to changes in  pressures or temperature of the incoming water  supplies  to maintain the selected temperature  An  adjustable maximum temperature stop is provided  which limits the temperature to a safe level   Inlet filters are fitted to protect the thermostatic  cartridge     Patents    Patents    GB  2 340 210  2 392 223  2 392 224  Patent Applications   Euro  1 672 257   US  2006 0124758 A1          SAFETY WARNINGS          PACK CONTENTS             Mira thermostatic mixers are precision engineered  and should give continued safe and controlled  performance  provided     1     They are installed  commissioned  operated and  maintained in accordance with manufacturers  recommendations       Periodic attention is given  when necessary     to maintain the product in good functional  order     Caution     1   2   3     Read all of these instructions    Retain this guide for later use    Pass on this guide in the event of change of  ownership of the installation site       Follow all warnings  cautions and instructions    contained in this guide       Anyone who may have difficulty understanding    or operating the controls of any shower should  be attended whilst showering  Particular  consideration should be given to the young   the elderly  the infirm or anyone inexperienced  in the correct operation of the controls       Rapid Excessive movement of the flow and     or temperature control levers may result in  momentary unstable blend temperature
11. ntrol    Turn the flow lever clockwise to the maximum  flow           USER MAINTENANCE          If you require a Mira trained service engineer or  agent  refer to section     Customer Services        Fault Diagnosis    Symptom     Only hot or cold water from the mixer outlet   Outlet temperature too hot   too cold     Cause Rectification     Inlets reversed  hot supply to cold supply    Rework inlet pipework     No hot water reaching mixer   Check the filters for any blockage     Installation conditions outside operating  parameters  refer to sections     Specifications     and    Commissioning        Symptom     Fluctuating or reduced flow rate     Cause Rectification     Check the shower handset  hose and filters  for any blockage     Make sure that the maintained inlet pressures  are nominally balanced and sufficient  refer  to section     Specifications        Make sure that the inlet temperature  differentials are sufficient  refer to section      Specifications       Flow regulator fitted incorrectly    Air lock or partial blockage in the pipework     Symptom     Water leaking from shower handset     Cause Rectification     Normal for a short period after shut off     Check that the pressures are not in excess of  the specifications for the product     Renew the mixer valve assembly     10    Lubricants    Silicone based lubricants must only be used on  the rubber seals    Caution  Oil based or other lubricant types may  cause rapid deterioration of seals     Cleaning  
12. obtained before return   Please contact our Customer Services Team    Note  In the interests of safety  spares requiring exposure  to mains voltages can only be sent to competent persons     Service   Our Service Force is available to provide a quality service  ata reasonable cost  You will have the assurance of a Mira  trained engineer agent  genuine Mira spare parts and a  12 month guarantee on the repair    Payment should be made directly to the engineer agent  using Visa  MasterCard or a cheque supported by a  banker s card     To Contact Us   England  Scotland  Wales and Northern Ireland   Mira Showers Customer Services   Telephone  0870 241 0888  Mon to Fri 8 00 am   5 30 pm  Sat 8 30 am   3 30 pm    E mail  technical  mirashowers com   Fax  01242 282595   By Post  Cromwell Road  Cheltenham   Gloucestershire  GL52 5EP   Eire    Modern Plant Ltd  Dublin     Telephone  01 459 1344  Mon to Fri 9 00 am   5 00 pm    E mail  sales  modernplant ie  Fax  Dublin 01 459 2329  Post  Otter House  Naas Road     Clondalkin  Dublin 22  Modern Plant  Cork   Telephone  021 496 8755  Mon to Fri 9 00 am   5 00 pm    E mail  cork  modemplant ie  Fax  021 496 8607  Post  Tramore Road  Cork    mira  AS    SHOWERS       FM 14648       Kohler Mira Limited  October 2007    plumbworld    Big brands  small prices     Pdf Supplied By http   www plumbworld co uk       
13. osely fitted over  the mixing valve inlets and align the mixer  with the inlet nuts  Push on fully and tighten  the grubscrews to secure the mixer to the  backplate  Make sure that the grubscrews are  engaged fully in the valve body grooves     Inlet Filters       Concealing Plate          13 Push the concealing plate onto the backplate     secure with the M4 x 12 mm grubscrew     Single grubscrew secures  the top inlet to the backplate       Two grubscrews securing both the  bottom inlet and the concealing  plate to the backplate     14 Fit the shower fittings  refer to your shower  fittings installation and user guide for  instructions   Important  A 12 litre minute flow regulator  is fitted inside the outlet nipple  This can be  removed for gravity fed   other low pressure  systems  0 5 bar or below           12 L Min Flow  Regulator    Hose  Washer    15 Turn on the hot and cold water supplies and  check for leaks    16 Before using the shower  refer to section      Commissioning           COMMISSIONING             OPERATION             Maximum Temperature Setting    Before using the shower the maximum temperature   must be checked to make sure that it is at a   safe level  It has been preset to approximately   43  C at the factory but due to variations in site   conditions the maximum temperature may need   adjustment    Note  Make sure that the hot water temperature is   at least 55  C and that there is sufficient supply    1  Turn on the mixer to the maximum temperatur
14. s       Care is required when adjusting flow or    temperature  make sure that the temperature  has stabilised       Do not remove or tighten the body grubscrews              Caution  Do not remove or  tighten these grubscrews     ae                     When this product has reached the end of its    serviceable life  it should be disposed of ina  safe manner  in accordance with current local  authority recycling  or waste disposal policy           Tick the appropriate boxes to familiarise yourself  with the part names and to confirm that all of the    parts are included     U 1 x Thermostatic Mixer           supplied fitted to the backplate     g    0 1 x Concealing Plate    QQ L 1 x M4x 12 mm Grubscrew       OO U 2x Olives    Tess T 4 x Wall plugs    RPP CO 4 x Fixing Screws  VA L 1 x 2 mm Hexagonal Key       Documentation    U 1 x Guarantee Registration Document          SPECIFICATIONS    Pressures          Max Static Pressure  10 Bar   Max Maintained Pressure  5 Bar     Min Maintained Pressure  Gravity System    0 1 Bar   0 1 bar   1 Metre head from cold  tank base to shower handset outlet      Note  For gravity fed   other low pressure  systems  0 5 bar or below  remove the outlet  flow regulator  Refer to section     Installation   Flow Regulator        For optimum performance supplies should be  nominally equal     Temperatures    9 Factory Pre set  Blend  Shower  43  C     9 Optimum Thermostatic Control Range  35  C  to 43  C  achieved with supplies of 15  C cold   65
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Passion Architecture N°51  Aqua2Go GD86 high-pressure cleaner  Finisar XFP 1310nm 10km SMF  DCR45 主要諸元 安全に関するご注意  eprofile guidance 20110504 - Medway Council  V I AT User's Guide v0.3  marque: brandt reference: wtd 6084 sf blanc codic: 3286959  F3说明书.indd 2-3 2014-1  Manual - KanexPro  Siemens WD14H420 washer dryer    Copyright © All rights reserved. 