Home

808273 - Spot Thermometer User Guide

image

Contents

1. Page 16 User Guide SPOT Thermometer 4 7 Time Functions The Time Functions menu allows you to select which time functions are applied to the thermometer temperature readings Menu Option Output Time The Output Time option allows you to specify a time interval over which temperature measurements are averaged The range of possible measurements is 1 to 10 000 milliseconds 10 seconds The Averager option allows you to specify a further number of values over which the temperature measurement is averaged i e smoothed The number you specify corresponds to the number of Output Time intervals over which the measurement is averaged i e Averager set to n smooths over n output time intervals This is useful if you want to smooth out any intermittent spikes or troughs in the target temperature The range of possible measurements is 1 to 255 values ModeMaster The ModeMaster option is a function which can be used in applications such as viewing a stream of hot metal In such applications there is likely to be occasional obscuration of the target by smoke or other interference this would lead to lower and extremely variable temperature readings Conversely sparks or cavitation in the metal stream would lead to high but short lived readings The ModeMaster function minimises both types of error by continuously buffering and filtering batches of temperature readings over a specific time period approx
2. LAND AMETEK PROCESS amp ANALYTICAL INSTRUMENTS SPOT Thermometer User Guide Publication N 808273 Issue 4 07 March 2014 Language English Land Instruments International 2014 AMETEK IMPORTANT INFORMATION PLEASE READ Health and Safety Information Read all of the instructions in this booklet including all the WARNINGS and CAUTIONS before using this product If there is any instruction which you do not understand DO NOT USE THE PRODUCT Safety Signs NOTE Indicates a potentially hazardous situation which if not avoided could result in damage or the loss of data Equipment Operation Use of this instrument in a manner not specified by Land Instruments International may be hazardous Read and understand the user documentation supplied before installing and operating the equipment Protective Clothing Face and Eye Protection It is possible that this equipment is to be installed on or near to machinery or equipment operating at high temperatures and high pressures Suitable protective clothing along with face and eye protection must be worn Refer to the health and safety guidelines for the machinery equipment before installing this product If in doubt contact Land Instruments International Electrical Power Supply Before working on the electrical connections all of the electrical power lines to the equipment must be isolated All the electrical cables and signal cables must be c
3. detector to be used for temperature measurement Duo In thermometers with more than one detector fitted the Duo option selects the longest wavelength detector at lower temperatures and switches smoothly and automatically to the shorter wavelength detector at high temperatures Ratio In thermometers with more than one detector fitted the Ratio option selects both detectors to be used for temperature measurement The thermometer will operate as a ratio thermometer which allows measurement on partially obscured targets or targets which do not fill the thermometer field of view completely and of processes where emissivity changes across the wavelength band of both detectors When the Ratio option is selected an extra Signal strength output is available Multi This option enables the extended temperature range of a thermometer It uses the Ratio mode at higher temperatures where both detectors measure and uses the longer wavelength detector coupled with signal measurement from the ratio algorithm to give a temperature output when measuring below the normal minimum temperature limit APP The APP option allows you to select the Application Specific temperature regime of your thermometer if configured This is used in conjunction with App 1 X setting App 1 X The App 1 X option allows you to select the particular application specific temperature measurement mode for your thermometer This is used in con
4. configure your system and display temperature readings on your PC See Section 3 2 3 3 Connecting to a Windows 7 PC when the firewall is blocking access You need to configure the connection as a work network so that it will permit access 1 2 3 Page 6 Set the IP address and Subnet mask on your computer as normal similar but not the same as the instrument e g 10 1 10 52 subnet mask 255 255 0 0 Then set the Default Gateway as the IP address of the instrument e g 10 1 10 50 When you click OK and close the box a box should open asking you to select the network location select Work network Otherwise double click on the network in the Network and Sharing Centre to select the network location If the firewall is still blocking access open Windows Firewall from the Control Panel The first menu item is Allow a program or feature through Windows Firewall which may be necessary for the System 5 SPOT Calibration software It is also a good idea to click on Change Notification Settings make sure that Block all incoming connections is not ticked User Guide SPOT Thermometer 3 1 Using the Thermometer Controls Using the Display and Keypad The thermometer has a back panel display which when used in conjunction with the keypad buttons can be used to Display the Target temperature and the internal ambient temperature of the instrument as shown in Fig 3 1 Display the alarm status of the target and the
5. finde ssi lee P Select Google wo search Hg shee More Signin A WE Sr Lan SPOT TN wmemater Fig 3 2 Web Server Interface Refer to Section 3 3 for a key to the items Page 8 User Guide SPOT Thermometer 3 3 Display and Web Server interface components The following table give a description of the items shown in Figs 3 1 and 3 2 Item Name Description Up Down Keys On the Home screen i e Temperature display pressing either key toggles between the Temperature display screen and the Info screen The Info screen will time out and revert to the Temperature display When in the menu system scrolls up down to the previous next menu On the thermometer display only Pressing either key cycles through the Temperature display Camera display and Info screens When a menu option is selected highlighted either increases decreases the value of the item or scrolls up down through the options available for that item Name User defined name for thermometer measurement location IP Address The IP address of the thermometer set by user LAND logo On the Web Server only Click to open an online Web Server simulator and help pages SPOT logo On the Web Server only Returns you to the Web Server Home screen i e Temperature display Target Temperature Displays the target temperature by default or Displays the Info screen if either the Up or Down key Menu Display is pressed Switches to the men
6. option resets the thermometer settings to factory default values Note selecting this option will lose any changes that you have made to the thermometer settings This option allows you to specify a name label or location identifier for the thermometer connected to the Web Server e g Furnacel The maximum name length is 8 characters The Lock option allows you to password protect the screens on the SPOT Web Server so that changes cannot be made to any of the settings When the Lock function is enabled you will have to enter the correct Unlock code in order to make any further changes to the system Page 19 LAND AMETEK PROCESS amp ANALYTICAL INSTRUMENTS PRODUCT WARRANTY Thank you for purchasing your new product from Land Instruments International This Land manufacturer s back to base warranty covers product malfunctions arising from defects in design or manufacture The warranty period commences on the instrument despatch date from the Land Instruments International Ltd factory in Dronfield UK 36 MONTHS WARRANTY Building upon the reputation for reliability and longevity that System 4 and UNO thermometers have earned Land are delighted to be able to provide our customers with an industry leading 36 month warranty for the following products e SPOT thermometers accessories and mountings and special instruments based on SPOT e System 4 thermometers processor
7. settings will be available The emissivity of an object varies with wavelength A Ratio thermometer uses two detectors at different wavelengths Therefore a ratio thermometer sees two different emissivity values one detector tends to see more energy than the other Traditional ratio instruments only require a non greyness input the actual emissivity for each detector is not required The new SPOT algorithm uses both 61 and amp 2 to allow calculation and output of the signal strength If you don t know the 1 and 2 values explicitly set 1 NG and 2 1 The temperature measurement depends only the ratio of emissivities The signal strength output will reflect both obscuration and the true emissivity of the target If you have a query regarding the emissivity of the target in your measurement application contact Land Instruments International Non Greyness If the instrument is used in Ratio mode the non greyness is calculated from the 61 amp 2 value and is displayed on the Info screen If you have a query regarding the non greyness value of the target in your measurement application contact Land Instruments International Units The Units option allows you to specify whether temperature is displayed in C Celsius or F Fahrenheit Background The Background menu option allows you to specify the temperature of the surroundings of the target object being measured This is especially useful if the surroun
8. to advise you on the correct returns procedure Any item returned to Land Instruments International should be adequately packaged to prevent damage during transit You must include a written report of the problem together with your own name and contact information address telephone number email address etc Design and Manufacturing Standards The Quality Management System of Land Instruments International is approved to BS EN ISO 9001 for the design manufacture and on site servicing of combustion environmental monitoring and non contact temperature measuring instrumentation 150 Approvals apply the USA BARRAGE EAT YETH C This instrument complies with current European directives relating to Electromagnetic Compatibility 89 336 EEC and Low Voltage Directive 73 23 EEC The Quality Management System of Ametek Motors Shanghai Co Limited is approved to ISO9001 2008 for the Design and Manufacturing of Motors and the Manufacturing of Gas Analysers Operation of radio transmitters telephones or other electrical electronic devices in close proximity to the equipment while the enclosure doors of the instrument or its peripherals are open may cause interference and possible failure where the radiated emissions exceed the EMC directive The protection provided by both CE and IP classifications to this product may be invalidated if alterations or additions are made to the structural electrical mechanical or pneumatic parts
9. to enable disable the use of the CMD output as a watchdog output which toggles between open and closed every 1 second Page 14 User Guide SPOT Thermometer 4 4 Network The Network menu allows you to specify the mode of network connection and to set the default IP Address for the thermometer The MAC address of the thermometer is displayed on this screen as read only information Menu Option The Mode option allows to specify whether the network mode is Set IP or DHCP The Set IP option allows you to set an IP Address manually The DHCP option enables IP addresses to be assigned automatically by the network on which the thermometer is installed DHCP allows a computer to join an IP based network without having a pre configured IP address DHCP is a protocol that assigns unique IP addresses to devices then releases and renews these addresses as devices leave and re join the network The default IP address is used if the Set IP option is selected and is also used if the network cannot assign one via DHCP Default IP The Default IP option allows to specify the default network IP address of the thermometer 4 5 Focus The Focus menu allows you to adjust the focus and switch on the integral LED which can be used as an aid to focusing the thermometer It will switch off automatically after 30 seconds Menu Option LED The LED check box allows you to switch on off the integral LED which can be used as an aid to f
10. 2 seconds The average temperature over this time period is calculated and displayed Page 17 SPOT Thermometer User Guide Menu Option Description Peak Picker Adjustable decay rate Delay Threshold level OFF Delay Time The Peak Picker function can be used to monitor the highest temperature measured by the thermometer This feature is useful especially for moving targets and or where the target is obscured partially e g a steel slab on a rolling mill where parts of the surface are covered with scale The clean area will be at the higher i e true temperature The Peak Picker has the following features Mode Peaks or Valleys Peaks this mode measures and tracks the highest temperature as illustrated Valleys this mode measures and tracks the lowest temperature Threshold level Temperature above which the Peak Picker is active used in conjunction with the ON and OFF delay On Delay Time period between the temperature rising above the threshold level and the Peak Picker function switching on Decay Time A user adjustable value at which the stored temperature output signal decays Off Delay Time period between the temperature falling below the threshold level and the Peak Picker function switching off Off Mode Hold Reset or CMD In Reset Hold at the end of the Off Delay the temperature output value is held constant until the temperature input next rises above
11. cal Area Connection option and select Properties EJ Broadcom Mebstreme 57x Gigabit This connection uses the following items File and Printer Sharing for Microsoft Networks aos Packet Scheduler Internet Protocal TCP IP 4 Inthe Local Area Connection Properties dialog select the Internet TCP IP Protocol option and click the Properties button 5 Inthe Internet Protocol TCP IP Properties dialog select the Use the following IP address option and set the IP address to one similar to but not the same as the IP address of the thermometer The current IP address is shown on the rear display when in temperature measurement mode The default address is 10 1 10 50 6 Setthe Subnet mask to 255 255 0 0 and click OK 7 Click OK to close the Local Area Install Uninstall Description Transmission Control Pratacnl Intermet Protocol The default wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited er no cennectivity Intermer Protocol TCISIIP Properties MIR Dira You can get IP cating i y your E li ss pou remm bo ach your Pai the ced rage C btsn ars aides anctor tac ale e LH ie Hess ole nce E IP aT 10 57 Connection Prope
12. ccess the system click on the Enter key The Up and Down keys are used to either navigate through the menu system or to change the value of a selected item on the display The Enter key is used either to select a menu item or confirm a new value setting for a selected item The main menu gives access to a series of sub menus which allow configuration of all the instrument settings Advanced n Setings lo Focus EXIT Alam Tire Functions Adhanced Exit Thermometer menu Web Server menu Fig 4 1 A graphical representation of the menu system is given in Fig 4 2 overleaf and the various settings are explained in the following sections Page 10 SPOT Thermometer User Guide oJnjonajs J9AJeS q M pue Ae dsip T p ierg aeg APA Avr 3ususnuisug Pm uDu4 sbuniss m Page 11 SPOT Thermometer User Guide 4 2 Settings The Settings menu allows you to specify basic measurement options for your System Menu Option Emissivity In order to obtain accurate temperature measurements the Emissivity value of the target surface must be known If you are using a single detector thermometer or using a dual detector thermometer in Mono mode only one Emissivity setting will be available If you are using a dual detector thermometer both the Emissivity 1 and Emissivity 2
13. dings are at a higher temperature than the target object e g when measuring a steel slab in a reheat furnace The Background temperature value you set will be used by the thermometer to compensate for the effect of the hot surroundings on the temperature measurement Process Window The Process Window option allows you to specify whether or not the thermometer is viewing the target through a sealed to process window If there is a window between the thermometer and the target there will be a decrease in the signal received by the thermometer due to transmission losses in the window By specifying that a process window is present in your measurement application the instrument will compensate automatically for the transmission losses and the correct temperature will be displayed Continued Page 12 User Guide SPOT Thermometer Menu Option Mode The Mode menu option allows you to specify the temperature measurement mode of the thermometer A description of each mode available for SPOT is given below The Mode options available in your thermometer will depend upon the type of thermometer you are using and the detectors fitted in the thermometer Mono 1 In thermometers with more than one detector fitted the Mono 1 option selects the shortest wavelength detector to be used for temperature measurement Mono 2 In thermometers with more than one detector fitted the Mono 2 option selects the longest wavelength
14. easier to use than ever before Ethernet Modbus TCP Video and analog communications are combined within one thermometer and all are available to the operator All essential operator information can be viewed either on the sensor s rear display panel remotely in a control room or via a web server Features Through the lens integrated camera Easy target alignment in low and high temperature environments o Rear display e Target focusing temperature reading and set up through simple menu driven software LED Sighting no laser safety requirements the sensor confirms the focus distance and spot size pulsing green red LED simplifies sighting on all targets e Single person installation at sensor location no need to verify control room readings Industry standard 4 to 20mA temperature output e Single Sensor Solution Ideal for use with customer PLCs or DCS systems no requirement for a separate processor The focus display LED is a unique feature which provides a precise confirmation of the thermometer focus distance and target spot size at that distance This function replaces target size tables and takes the math or guesswork out of this calculation Flexible design provides multiple form factors resulting in simplified replacement of older thermometers SPOT is designed to be fully interchangeable with existing LAND fixed spot thermometers e g System 4 Page 1 SPOT Thermometer User Guide SPOT cable o
15. et 2 2 Connecting the Thermometer to a Computer Using the Digital Cable Kit 1 Insert the end of the cable RJ45 to M12 Digital Instrument Cable into the connector on the thermometer Fig 2 3 2 Insert the mains lead into the PoE Injector unit Fig 2 4 Fig 2 4 Page 3 SPOT Thermometer User Guide 3 Insert the other end of the RJ45 to M12 Digital Instrument Cable into the P DOUT connector of the PoE Injector Fig 2 5 4 Insert one end of the RJ45 cable into the Data IN connector of the PoE Injector Fig 2 6 Fig 2 6 5 Insert the other end of the RJ45 cable into the Ethernet connector on the Computer Fig 2 7 In order for the SPOT thermometer to communicate with the computer you will now need to set an appropriate IP address on the computer See Section 2 3 Page 4 User Guide SPOT Thermometer 2 3 Setting the IP address In order for the thermometer to communicate with the computer you must set an appropriate IP address on the computer The example below shows how to set the IP address in Windows XP and Windows 7 For other version of Windows refer to the user documentation or online help supplied with the Windows software 2 3 1 Windows XP 1 Open the Start menu and select the Control Panel option 2 Select the Network Connections Local Area Connection Properties General Advanced Connect using 3 option Right click on the Lo
16. instrument Display a video image of the target from the instrument s internal camera Activate the focusing LED which can be used to align and focus the instrument on the target Access the instrument menu system including the Info screen 10 1 10 50 MillExit 255 0 Typical Info screen Focusing LED display Fig 3 1 Rear panel controls and displays Refer to Section 3 3 for a key to the items Page 7 SPOT Thermometer User Guide 3 2 Using the Web Server Software The thermometer incorporates Web Server software which allows you to use a web browser to view temperature readings from the thermometer The browser display updates automatically every 5 seconds effectively turning the PC into a remote back panel for the thermometer The Web Server software interface is designed to mimic the controls on the rear panel of the SPOT thermometer and allows you to access the thermometer s menu structure and configure your temperature measurement system to your requirements 1 Ensure that your thermometer is installed correctly and connected to the PC Refer to Section 2 2 Open a web browser window e g Internet Explorer and type the IP address of the thermometer default 10 1 10 50 into the address bar The Web Server interface will open Fig 3 2 The interface mimics the rear panel of the thermometer shown in Fig 3 1 hermometer Windows Internet Explorer provided by Land Instruments 3 chp B0 2 10 SO
17. junction with APP setting Range The Range of the thermometer will depend on the Mode and is displayed for information purposes only You cannot change the range of the thermometer Page 13 SPOT Thermometer User Guide 4 3 I O The I O menu allows you to specify the settings for the current inputs and outputs from the thermometer Menu Option Mode The Mode option allows you to specify whether the analog output is 4 20mA or 0 20mA OmA or 4mA This option will depend up on the value you selected for the analog output in the Mode option It allows you to set the lower temperature limit of the analog current output i e the temperature that corresponds to an output of either OMA or 4mA This option allows you to set the upper temperature limit of the analog current output i e the temperature that corresponds to an output of 20m4A The Logic option allows to specify whether the Command input and output relays are Normally Open N Open or Normally Closed N Closed The CMD In option allows you to enable disable the Command Input and configure it to be either be a Sample amp Hold input or a Reset Peak Picker input A graphical representation of the Reset Peak Picker input is shown below Output Target temperature Time OV Command CMD Out If any alarms are in use the CMD Out relay is used as an alarm output If alarms are not used the CMD Out option allows you
18. ocusing the thermometer When focused correctly the LED pattern will be as shown below The central circle is aligned with the infrared detector and represents the temperature measurement area Flash Rate The Flash Rate setting allows you to specify the rate at which the focus LED flashes when enabled The Flash Rate can be set to between 1 and 30 Hz Set Focus The Set Focus option allows you to set the thermometer focus to any value within the focal range of the thermometer Page 15 SPOT Thermometer User Guide 4 6 Alarms The Alarms menu allows you to set high and low alarm temperature values for both the target being viewed and the ambient temperature of the thermometer When active an alarm state is indicated by red bars next to the camera image on the rear panel display or a red box around the data view on the display or Web Server Menu Option High Target The High Target option allows you to enable and set the high alarm threshold value for the target being viewed by the thermometer Low Target The Low Target option allows you to enable and set the low alarm threshold value for the target being viewed by the thermometer High Ambient The High Ambient option allows you to enable and set the high alarm threshold value for the ambient temperature of the thermometer Low Ambient The Low Ambient option allows you to enable and set the low alarm threshold value for the ambient temperature of the thermometer
19. of this system Such changes may also invalidate the standard terms of warranty Copyright This manual is provided as an aid to owners of Land Instruments International s products and contains information proprietary to Land Instruments International This manual may not in whole or part be copied or reproduced without the expressed written consent of Land Instruments International Ltd Copyright 2013 Land Instruments International SPOT Thermometer User Guide User Guide SPOT Thermometer Contents 1 Introduction 1 1 1 About the Spot Thermometer 2 Getting Started 3 2 1 Installing the Thermometer 3 2 2 Connecting the Thermometer to a Computer 3 2 3 Setting the IP address 5 3 Using the Thermometer Controls 7 3 1 Using the Display and Keypad 7 3 2 Using the Web Server Software 8 3 3 Display and Web Server interface components 9 4 Thermometer Web Server Menu 10 4 1 About the Thermometer menu Web Server menu system 10 4 2 Settings 12 4 3 I O 14 4 4 Network 15 4 5 Focus 15 4 6 Alarms 16 4 7 Time Functions 17 4 8 Advanced 19 SPOT Thermometer User Guide User Guide SPOT Thermometer 1 1 Introduction This User Guide gives you instructions on how to install and operate a LAND SPOT Thermometer About the Spot Thermometer SPOT Thermometers are high performance pyrometers featuring advanced integrated processing capabilities SPOT utilizes the latest technology to make spot temperature measurement more accurate and
20. onnected exactly as indicated in these operating instructions If in doubt contact Land Instruments International Storage The instrument should be stored in its packaging in a dry sheltered area Unpacking Check all packages for external signs of damage Check the contents against the packing note Lifting Instructions Where items are too heavy to be lifted manually use suitably rated lifting equipment Refer to the Technical Specification for weights All lifting should be done as stated in local regulations Contact Us UK Dronfield USA Pittsburgh Land Instruments International AMETEK Land Inc Tel 44 0 1246 417691 Tel 1 412 826 4444 Email land infrared ametek co uk Email irsales ametek com land combustion ametek co uk combsales ametek com Web www landinst com Web www ametek land com For further details on all LAND Ametek offices distributors and representatives please visit our websites Return of Damaged Goods IMPORTANT If any item has been damaged in transit this should be reported to the carrier and to the supplier immediately Damage caused in transit is the responsibility of the carrier not the supplier DO NOT RETURN a damaged instrument to the sender as the carrier will not then consider a claim Save the packing with the damaged article for inspection by the carrier Return of Goods for Repair If you need to return goods for repair please contact our Customer Service Department They will be able
21. ptions Digital Cable RJ45 Connector PoE Instrument Connector Digital cable options Digital Cable Part Cable length 807944 5 m 16 ft 5 in 807945 20 m 65 ft 7 in 807946 100 m 328 ft Analogue Cable LT Analogue Instrument Connector Free Ends Analogue cable options Analogue Cable Part Cable length 807950 5 m 16 5 807951 20 65 ft 7 in 807952 100 m 328 ft Analogue cable pin out details Red 24V Brown mA Out Blue mA Out Purple Relay 1A Green Relay 1B Yellow Trigger in White Trigger in Screen Screen Fig 2 1 Spot Cable Options Page 2 User Guide SPOT Thermometer 2 Getting Started A typical temperature measurement system incorporating a SPOT thermometer will include SPOT Thermometer o A thermometer mounting accessory such as a mounting bracket or water cooled jacket A computer running the Spot Web Server software Spot Viewer software e Cable s connecting the thermometer to the computer Cable details are given in Fig 2 1 opposite 2 1 Installing the Thermometer If you are using the thermometer in conjunction with a mounting accessory refer to the accessory s Installation Guide for help on choosing a location for the thermometer mounting dimensions and aligning the thermometer on the target Fig 2 2 shows a thermometer installed in Mounting Brack
22. rties dialog UT xx E a The IP address has been set Delal gatat You will now be able to use the Web Server software incorporated in the thermometer to configure your system and display temperature readings on your PC See Section 3 Use the hbraga DHS penser adheme Pitan sene Almere DNS sense J Cae Page 5 SPOT Thermometer User Guide 2 3 2 Windows 7 If you have problems connecting to a Windows 7 PC due to Firewall blocking access see Section 2 3 3 1 2 3 4 5 6 7 Open the Start menu and select the Control Panel option Select the Network and Internet option then select Network and Sharing Center Select the Change adapter settings option Right click on the Local Area Connection option and select Properties In the Local Area Connection Properties dialog select the Internet TCP IP Protocol option and click the Properties button In the Internet Protocol TCP IP Properties dialog select the Use the following IP address option and set the IP address to one similar to but not the same as the IP address of the thermometer The current IP address is shown on the rear display when in temperature measurement mode The default address is 10 1 10 50 Set the Subnet mask to 255 255 0 0 and click OK Click OK to close the Local Area Connection Properties dialog The IP address has been set You will now be able to use the Web Server software incorporated in the thermometer to
23. s accessories and mountings and special instruments based on System 4 e UNO thermometers accessories and mountings and special instruments based on UNO e Application dedicated processors based on LANDMARK Graphic e ABTS S and ABTS U e FTS e VDT S and VDT U e DIT e FLT5 A This 36 month warranty is provided as standard for all orders for the products listed above received from 1st May 2002 We believe that our customers expect us to set the standard in terms of performance quality reliability and value for money This 36 months warranty as a part of an on going program of continuous improvement is just one way in which Land strive to maintain our position as the temperature measurement partner of choice 24 MONTHS WARRANTY The following Land Instruments International products are provided with a 24 months warranty e e FTI E e 12 MONTHS WARRANTY All Land Instruments International products not provided with either a 36 month or 24 month warranty see lists above are provided with a 12 months warranty PRODUCT WARRANTY EXCLUSIONS FROM WARRANTY It should be noted that costs associated with calibration checks which may be requested during the warranty period are not covered within the warranty Land reserve the right to charge for service calibration checks undertaken during the warranty period if the cause is deemed to fall outside the terms of the warranty This Land manufacturer s warran
24. the threshold level Reset at the end of the Off Delay the temperature output signal falls to under range until the temperature input next rises above the threshold level CMD In reset Selecting this option allows you to reset the peak Picker at any time via the command input Page 18 User Guide SPOT Thermometer 4 8 Advanced The Advanced menu contains items which are likely to be used only occasionally These items control the look and feel of the Web Server interface and may be useful during set up Menu Option Language This option allows you to select the language for the Web Server interface screens LED This option allows you to switch on the LED which illuminates the thermometer s field of view and defines the target size This is useful for aligning the thermometer on the required target You can also define the frequency at which the LED flashes Demo LED When the Demo LED option is selected the LED is activated each time a key is pressed on the rear face of the thermometer The LED switches off automatically after a preset time Test Output This option allows you to switch on a test current output from the thermometer This is useful for confirming that the thermometer is operating correctly You can also specify the current in mA for the test output The test current output switches off automatically after 15 minutes Reboot This option restarts the thermometer Reset This
25. ty does not cover product malfunction arising from incorrect electrical wiring connection to electrical power sources outside the rating of the product physical shock being dropped etc and impact damage inappropriate routing Support physical shock amp strain protection etc of the lightguide Fibroptic thermometers only environmental conditions exceeding the IP NEMA rating of the product environmental conditions outside the Ambient Temperature Humidity and Vibration rating of the product environmental contamination solvent vapours deposition of airborne contamination cooling liquids of non neutral pH etc overheating as a result of interruption of water air flow through cooling jackets or of incorrect installation inappropriate modification of product drilling holes in thermometer bodies etc inappropriate recalibration which results in product calibration being taken outside specification improper resealing of thermometer following parameter adjustment UNO FLT5 A etc attempted repair by a non Land authorised repair centre Land Instruments International Ltd Dronfield S18 1DJ England e Tel 44 0 1246 417691 e Fax 44 0 1246 410585 Email land infrared ametek co uk www landinst com AMETEK Land Inc 150 Freeport Rd Pittsburgh PA 15238 U S A Tel 1 412 826 4444 Email irsales ametek com www ametek land com For a complete list of our international offices please visit
26. u system when the Enter key is pressed Enter Key On the Home screen i e Temperature Info display pressing the Enter key accesses the menu system When in the menu system pressing the Enter key selects the highlighted menu item for adjustment When a menu item is selected pressing the Enter key sets the menu item to the selected value An update to any menu item is confirmed by Internal Temperature Display Displays the internal temperature of the instrument Alarm Status Indicators High and low alarm values for both target temperature and instrument temperature can be set by the user Colour coded alarm status Green OK Red Alarm Signal strength indicator Only applicable if Ratio or Multi measurement mode is selected If Emissivities E1 and E2 are set correctly this value gives a measure of the reduction of signal strength due to obscuration e g when viewing through a dirty window Alternatively if the view is unrestricted this value gives a measure of the emissivity variation in the target surface Page 9 SPOT Thermometer User Guide 4 Thermometer Web Server Menu 4 1 About the Thermometer menu Web Server menu system The SPOT thermometer incorporates an internal menu system which can be accessed and viewed via the controls on the rear panel of the thermometer The menu system can also be accessed via the Web Server software built in to the thermometer Fig 4 1 To a
27. www landinst com Issue 2 27 July 2013

Download Pdf Manuals