Home
CELLROUTE-GSM Installation & User Guide
Contents
1. If NO RED LED with low pitch Interrupted Tone when handset lifted e Cannot detect a network signal See Reception is poor If RED LED flashing at 100ms on off e CellRoute is networked locked and does not recognise the networked SIM Installed GPRS unit Only RED amp GREEN LEDs flash 5 times e CellRoute is Initialising RED amp GREEN LEDs flashing on off at the same rate e Missed call Indicator RED amp GREEN flashing alternately at the same rate e CellRoute in data mode operation e Dial Tone Is Not Heard 1 2 3 Check that Power is connected Are batteries charged Min 30 minutes before use Check L E D status Both battery and signal strength LED should be lit 4 Check SIM lock is deactivated 5 6 During a power failure when battery back up is in use you may Check that the telephone connected is working correctly experience a delay of up to 4 seconds before dial tone is heard CELL ROUTE GSM WW alacomey Troubleshooting e Noise Is Heard during a Call This maybe due to poor signal strength or the unsuitable location of the CellRoute GSM It is recommended that CellRoute GSM is positioned a minimum of 1 meter away from other telephones and other electronic devices e Reception is Poor The CellRoute GSM comes with a built in antenna However If you are experiencing problems with poor reception check that you are getting adequate signal strength This can be achieved
2. e EN 301 419 1 Global System for Mobile Communications e ETS 300 342 1 Radio Equipment and Systems CELL ROUTE GSM ii Technical Specification telecomrm Features Overview High Ringer Equivalence POTS Interface Supports up to 4 additional extensions Highly compatible POTS user interface Integral Battery Back up Caller Line ID Presentation Bellcore Additional GSM network features may be available Subject to network availability and support RS232 Data Port for emails web and transmission reception of PC faxes using WinFax Pro SIM lock for asset protection For details contact your service provider Network Lock for asset protection For details contact your service provider Remote Software Upgrades Remote Antenna facility Off hook Howler Gain adjustment on microphone 1 gt 5 Gain adjustment on speaker 1 gt 5 Power Supplies Primary 110 240Vac 47 63Hz Secondary 2xA size NiMH rechargeable batteries with Auto switch over to mains failure Performance 11 hours standby time subject to Humidity and temperature Up to 2 hours Talk time subject to Humidity and temperature Physical Specifications Height 150mm Width 122mm Depth 42mm Weight 460gm Operational Temperature Range OC to 45C
3. lock feature This is a network security function For further details please contact your service provider SIM PIN Lock The CellRoute GSM has a SIM card PIN lock feature This is a SIM card security function For further details please contact your service provider Confidence Tone It is possible to turn confidence Tone ON or OFF Confidence Tone ON dial O 561 Confidence Tone OFF dial O 560 You will hear an acceptance tone once the digits have been dialled Ringing Cadence It is possible to adjust the ringing cadence for incoming calls to cell route To change dial O 8 1 4 1 USA 2 UK 3 SPAIN 4 ETR You will hear an acceptance tone once the digits have been dialled e Data Please refer to Data documentation e PC Fax Please refer to Fax documentation A 4 telecomrm T CELL ROUTE GSM ii Troubleshooting e First Things to Check If No Operation l 2 3 Check that Power is connected Check that SIM card is installed correctly Check that the telephone is connected correctly e LED Status l 2 If NO LED s are lit e Check for mains power If RED LED is flashing with high pitch Interrupted Tone when handset lifted check the following e No SIM connected e SIM has a PIN set and this is not recognised in Cellroute memory e SIM has been swapped with a SIM that has a PIN set which is not Recognised in Cellroute memory e Network lock is set to on with incorrect network SIM connected
4. CELLROUTE GSM Fixed Wi reless Terminal www discountcomms co uk di CellRoute GSV P telecomri Installation amp User Guide Version 05 Jan 2006 telecomey CELL Route GSM Document Control Date Doc Change Authority Version Apr 2003 1 release of document CH TB une 2003 Asset protection added CH TB Dec 2003 Adjustable gain settings amp line reversal CH TB Jan 2004 Selectable confidence tone amp Power fail Voltage CH TB Jan 2006 Notices amp WEEE Directive symbol added Notices Note The cellRoute GSM unit must be connected to the mains power and allowed to charge for a minimum of 30 minutes before use Emergency Calls This terminal operates using GSM signals which cannot guarantee connection in all conditions Therefore you should never rely solely on the terminal equipment for essential communications such as medical or emergency services If the mains plug is removed from the power socket the unit will switch to an internal battery supply As there will not be an Earth connection the output voltage to the telephone line will automatically be reduced This is to comply with the European Low Voltage Directive This may result in miss operation when using in some types of telephone This condition also applies for mains failure No responsibility is assumed by TFM for the use or reliability of the CellRoute GSM when used in a situation or with other equipment not supplied or specif
5. by moving the CellRoute GSM to another location for examples move closer to a window or higher up in the building In some locations your Coverage area may require a higher gain external antenna for optimal Call clarity and performance An external 3Db antenna is supplied with the unit see Connecting external Antenna Contact your service provider for advice on other types of external high gain antenna that can be connected to CellRoute GSM Call Control Line Voltage Loop Current Line impedance Ring Voltage Ring Load CLIP Transmit Power Speech Codecs Data Rate SIM Card Antenna Telephone Data Port GSM Antenna SIM Card Indication Telephony Interface DTMF 48v on hook 40mA off hook 600 ohm complex 70Vrms REN 4 Bellcore FSK GSM Interface E GSM 900MHz GSM 1800MHz GSM Phase 2 Class 4 2W for E GSM 900 MHz Class 1 1W for GSM 1800MHz Half Rate ETS 06 20 Full Rate ETS 06 10 Enhanced Full Rate ETS 06 50 06 60 06 80 2400 4800 9600 Baud 3V Integral Omni directional Antenna With MCX connector for external Antenna option Physical Interfaces Analogue RJ 11 RS232 RJ 45 with optional DB 9 Converter An SMA male connector 3V Small card retained under rear panel 2 x LED indication for battery Transmission Status Approvals CE Certification to R amp TTE directive 1999 S SEC GSM Certifications e ETS 300 607 1 Digital Cellular Telecommunications Systems
6. er Supply Provided e Connect a telephone to the CELLRoute GSM e Check Signal Strength e Make a test call Note The cellRoute GSM unit must be connected to the mains power and allowed to charge for a minimum of 30 minutes before use However for maximum battery standby performance the CellRoute GSM must be connected to the mains for a minimum of 4 hours Installing the SIM card Slide open the SIM cover Slide back the SIM door and lift it up Slide the SIM into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM Holder Close the SIM door Slide SIM door to lock the SIM in place Then replace SIM cover telecomey CELL ROUTE GSM Getting Started Location Of Cell Route For best reception locate your CellRoute GSM close to a window or on an external wall within a minimum of 330mm from any metallic object The unit must be a minimum of 1 meter from any other sensitive electronic equipment DO NOT locate in direct sun light or near any direct heat source Mounting the CellRoute GSM and Power Supply Bracket a ETETE ah Using the template provided mark piz location and fix with screws supplied Mount the Power Supply bracket within 1 meter from the CellRoute GSM Connecting a telephone or Computer e Connect your telephone s Into the RJ 11 socket provided e Connect your Computer into the RJ 45 socket provided Connectin
7. g the power Supply e Connect the Mains lead into the power supply unit then into the AC outlet e Connect the power cord from the power supply unit to the CellRoute GSM Connecting external Antenna if required To activate the external antenna move the antenna switch to the up position and screw the external antenna into the SMA connector provided External Internal B Antenna B Antenna SMA SMA Connector Connector CELL ROUTE GSM U Getting Started 7 telecom EM Powering Up CellRoute GSM Note The cellRoute GSM unit must be connected to the mains power and allowed to charge for a minimum of 30 minutes before use On power up the RED and GREEN LEDs will flash 5 times The Green LED will come on and remains on The RED LED will light up for approximatelv 10 seconds and then go out for approximatelv 10 seconds Once the unit has logged onto the GSM Network the Red LED will come back on Making a test call Make a test call with the phone connected to the CellRoute GSM On completion of dialled digits vou will hear a confidence tone indicating the call is successful Pressing the key after the dialled digits results in a faster dial up The RED LED will start to flash when the handset is lifted on the telephone indicating signal Strength Once the call is connected the RED LED will flash for 45 seconds indicating signal strength then stop leaving both RED and Green LED lit Number of flashes Signal stre
8. ied by TFM TelecomFM shall accept no liability for any error or damages of any kind resulting from the use of this document or the equipment it relates to The wording in this document may change from time to time Please refer to the TelecomFM web site WWW telecomfm co uk for the latest release Declaration of Conformity tela COM raa Applicant lelecomFM Ltd Address B95 Plymouth Road Slough L1 ALP Berkshire U K Product Gell Route www discountcomms co uk This equipment complies with the European R amp TTE Directive no 1999 S EC on radio and telesammunication herria equl prrerit lelec omit Signed JINSA May 2002 Roger Lew mgton telecoMem CellRoute GSM Introduction Thank you for the purchasing the Cell Route GSM terminal The CellRoute GSM incorporates e CellRoute GSM terminal 1 e Internal Antenna 2 e RJ 11 Telephone connector 3 e RJ 45 Data port 4 e L E D Indicators 5 e Power Connection 6 e External Antenna Connection amp Switch 7 CELL ROUTE GSM YielecoMev Getting Started Setting up the terminal Remove the CELLROUTE GSM from the packaging and proceed as follows Warning To avoid damage do not connect power until you have inserted the SIM card e Install the SIM card Making sure the PIN lock is deactivated if applicable e Install the CELLRoute GSM in preferred location following guidelines e Connect Power to the CELLRoute GSM using Pow
9. ngth in dB lt 81dB KT s 81dB 5 lt 67dB gt 67dB amp lt 59dB gt 59dB It is possible to Set Incoming amp Outgoing volumes on CellRoute Outgoing volume adjustment on microphone To adjust the microphone level e Lift the receiver e Dial O 6 e Dial 1 to 5 followed by 1 sets lowest volume 5 sets highest volume You will hear an acceptance tone once the digit has been dialled Incoming volume adjustment on speaker To adjust the Speaker level e Lift the receiver e Dial O 3 e Dial 1 to 5 followed by 1 sets lowest volume 5 sets highest volume You will hear an acceptance tone once the digit has been dialled 7 CELL ROUTE GSM 7 telecom EM ri Getting Started Answering Incoming calls Lift handset and call is connected Missed Call If both L E Ds are flashing simultaneously this is identifying a missed call Switching Off the CellRoute When switching off the CellRoute GSM you must first unplug the power cord from the CellRoute GSM itself otherwise this will activate Battery back up Battery Backup In the event of mains failure the CellRoute GSM s battery backup will automatically activate giving a standby time of approximately 12 hours anda talk time of 2 hours these figures are subject to humidity and temperature During a power failure when battery back up Is in use you may experience a delay of up to 4 seconds before dial tone is heard Network Lock The CellRoute GSM has a network