Contents
1. 2 5 variation around the current measured ambient temperature HI indicates plus variation LOW indicates minus variation Current ambient To enter DELAY setting screen press SET seven 7 temperature times TEMP DIFF setting symbol Variation TEMP DIFF screen with 1 5 C adjustment above the measured ambient TEMP DIFF screen with 1 00 adjustment bellow the measured ambient US ONLY B22 ENABLE Enable Disable B22 Offset Use this screen to enable or disable temperature offset for B22 boilers US and Canada models only 10 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT MANUAL OVERRIDE Manual Override Symbol 35 6 24 Ii 35 gazon To temporary switch from COMFORT mode to ECONOMY mode press ECONOMY mode button ALE To temporary switch from ECONOMY mode to COMFORT mode press COMFORT mode button Manual Override Quite often it is required to change temperature set point in flight without actually changing already active program Ts930 allows seamless temporary set point adjustment For either COMFORT or ECONOMY modes press adjust buttons to alter the current set point temperature Manual Override during COMFORT program Simply use adjust buttons to increase or decreas
2. ADJUST TURN ON TURN OFF 2 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT COMFORT MODE Comfort TEMP determines state of the output Current room temperature is displayed in the middle current time at the bottom of the screen Top right corner presents COMFORT MODE Set Point with its adjustment keys The FAN symbol indicates an active output Note that hour bar graph is enabled between 6AM and 11AM 24 hour bar graph clear fields indicate ECONOMY MODE filled entries indicate COMFORT MODE ECONOMY MODE Economy TEMP determines state of the output Current room temperature is displayed in the middle current time at the bottom of the screen Bottom right corner presents ECONOMY MODE Set Point with its adjustment keys Note that hour bar graph is clear between 9AM and 4PM 24 hour bar graph clear fields indicate ECONOMY MODE filled entries indicate COMFORT MODE DEFROST FEATURE DEFROST active See section DEFROST FEATURE CURRENT MODE OFF CLOCK CONFIGURATION Press TIME button at the toolbar The display changes as depicted bellow Use upper adjustment keys for setting the day of the week and lower adjustment keys for setting current time Press and hold for high speed scan to commence Once the setting is complete press to TUE revert back to no
3. ROOM THERMOSTAT Select HEAT OFF or COOL plus Defrost Feature ele pee This section deals with operating mode selection and DEFROST feature Choose between HEAT OFF or COOL plus enable or disable DEFROST feature DEFROST feature is intended to keep ambient temperature above 7 C at all times Once enabled and the system is in HEAT mode Ts930 will engage the output if ambient temperature falls bellow 7 C To start press SET button on the command bar as depicted to the left Display will now change to mode selection screen where SELECTION symbol is shown At the same time current operational mode symbol will also be shown As default this will be the HEAT mode symbol as MODE Selection Screen with presented to the left HEAT as current active mode Jd 4 GE SELECT HEAT COOL OFF DEFROST To shuffle between modes press SELECT button until next mode symbol appears and the current one turns off Repeat the procedure until Press SELECT BUTTON to change current MODE required mode symbol is displayed To save the chosen operating mode press SET User now have option to proceed with DEFROST feature enable disable option by pressing SELECT or simply to return to normal operating mode by pressing OK Defrost feature can be disabled or enabled status of which is indicated by presence of a defrost symbol snowflake at the lower right corner of the screen After pressin
4. TOUCH SCREEN ROOM THERMOSTAT TIME PRoG Crags Cic 5s IG Ci ERE meret BALAZ Features BLUE BACK LIT Touch Screen Comfort and Economy Mode Set Points Anti Frost Feature Vacation Setting Simple To Program Fits Conventional Wiring Display Symbols Oo 85 1115 24 Hour Clock Week Days 24 Hour Bar Graph Empty Hours Economy Mode Filled Hours Comfort Mode Current Room Temperature Economy Temperature Set Point Comfort Temperature Set Point Comfort Set Point Adjust Keys Economy Set Point Adjust Keys Week Days Adjust Keys 0 Clock Adjust Keys 1 System Heat Cool Symbols within Select Button Area ei Output Active Symbol 13 Low Battery Indicator Time Setting Symbol Program Setting Symbol 16 SET Mode Symbol 17 Manual Override symbol Defrost symbol TOUCH SCREEN ROOM THERMOSTAT Heating or cooling program Feature program sequence STANDARD USER STANDARD USER SCREEN MODE SCREEN MODE YE SELECT Q COMFORT MODE OPERATING MODE ECONOMY MODE SELECTION SCREEN OFF ENABLE DISABLE SET VACATION DURATION VACATION SET UP SCREEN SET VACATION SET POINT TEMPERATURE CHOOSE FURTHER DAYS SET DIFERENTIAL 1 C HEAT COOL CYCLE TEMPERATURE DIFFERENTIAL STORES NEW PROGRAM SETDIFERENTIAL 2 C ENABLE DISABLE ENABLE DISABLE SET TEMPERATURE
5. e current set point Ts930 will display manual override symbol Manually adjusted set point will remain active until end of COMFORT time frame Manual Override during ECONOMY program Simply use adjust buttons to increase or decrease current set point Ts930 will display manual override symbol Manually adjusted set point will remain active until end of ECONOMY time frame Manual Override Reverse Status It is very simple to switch between COMFORT and ECONOMY modes by selecting COMFORT or ECONOMY buttons from the command bar The action is followed by manual override symbol being displayed and this mode will remain active until the current hour ending 11 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT TS930 DIMENSIONS 32 SET so SEES MG TO WE THER SAS po mn 96 28 80 gt WIRING DIAGRAM TECHNICAL DATA Power Rating 230VAC 50Hz Switching Capacity 4A Resistive Temperature Range 0 C 35 C Setting Temperature Range 5 C 30 C Power 2x AA Alkaline Batteries Data Subject to Change Without Notice X PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK
6. g SET DEFROST symbol will appear flashing at the lower right corner of the screen Flashing of the defrost symbol indicates defrost currently disabled To enable press SELECT button Defrost symbol will now stop flashing defrost thus being enabled To alternate defrost mode press SELECT as required Once complete press at the command bar to exit configuration mode and return back to normal display ese ceps e COOL selected SET r ser ok TIME HA Press OK to exit configuration A and revert back to normal operating mode Press SET to confirm and Press SELECT BUTTON to save enter defrost configuration DEFROST Symbol Flashing Disabled Solid Enabled 5 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT VACATION SETTING Time PROG SET Vacation Setting is provided to allow special temperature set point to be 5 ae GE et gi active during several consecutive days without changing normal COMFORT and ECONOMY settings This is useful when property is not rei to be occupied for several days but the system is still required to T MO TU WE TH FR SA SU ce maintain certain ambient temperature 4 d 18 88 B Vacation setting can be enabled for a maximum off 99 consecutive days To configure vacation setting press SET at the command bar several t
7. imes until symbol UC appears on the screen see left To enter Vacation Setting screen press SET three 3 2 Vacation Setting Symbol times Vacation Duration Days Vacation Set Point Temperature Use left right vacation duration adjust keys to set the required vacation period maximum 99 days Use up down vacation set point adjust keys to program the vacation set point temperature This set point will become immediately active and will remain such for the duration of the vacation period Press OK to confirm and return to the normal display mode Screen will now show UC vacation symbol and vacation set point temperature bellow it The current ambient temperature and clock are displayed as normal This screen will remain for the duration of the vacation period Screen will now show UC To cancel vacation setting enter the vacation setting screen and set the vacation symbol and vacation vacation duration to zero 0 set point temperature 6 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT COOLING or HEATING TEMP DIFFERENTIAL n T 88 Cooling or Heating temperature differential This setting be adjusted E t BE to 1 or 2 C When enabled it will exclude potential temperature Li MM oscillations near to set point temperature MO TU WE TH FR SA SU 88 88 y To configure
8. ol FR for Friday is blinking underneath the current day program bar Use left and right adjustment keys to select day in the week and then press SELECT button above the current day program bar Note that once SELECT button has been pressed the day symbol stops blinking and new day symbol appears Now you can select further days to contain the same program by again clicking adjust keys followed by SELECT button Repeat this procedure to select all desired days Note at least one day in the week has to be selected to enable further steps of the programming sequence To continue to Schedule Programming press button at the command bar For this specific setting COMFORT and ECONOMY hours have to be specified The selection is displayed on current day program aoc WES Mo GM PE bar COMFORT hour entries are indicated with black rectangle while 15 00 D ECONOMY hour entries are empty hour slots Use cursor to select specific hour by pressing adjustment keys left and right from the current clock Once at the required hour slot press SUN to select COMFORT or MOON to select ECONOMY mode Repeat the procedure for all hours of the day Once complete press OK button at the command bar to revert back to the normal operating mode Jua 10 35 EXIIT IS 4 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN
9. rmal operating mode wg Os 55 Day adjust keys pe pere Time adjust keys 3 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT 7DAY PROGRAM EXAMPLE Time mi This section deals with 4 th mim 86 Adjusting comfort and economy temperature set points for single or m 5 sequence of days a week Also see Heating or Cooling Program Chart a Page 2 MO TU WE TH FR SA SU ce ad 18 88 B Comfort temperature is household target temperature during the hours of occupancy and is generally assumed to be the temperature for which the heating system is to be active Economy temperature is assumed to be the temperature during hours when heating system is not required usually during daytime on workdays To start press PROG key at the command bar Top right corner shows COMFORT set point temperature SUN symbol as COMFORT MODE symbol and its related adjustment keys Centre temperature presents ECONOMY MODE set point with its MOON symbol and related adjustment keys wee ix uum x ser ox c Directly press the adjustment keys to configure the required set points for a specific day in the week Once completed press PROG button on the toolbar Select Button Area PROG SET The screen now changes to allow selection of the day in the week Symb
10. temperature differential press SET button at the command bar four 4 times The status is displayed as ON or alternatively OFF Use the SELECT button to alternate Once configured press OK to return to normal mode screen To enter TEMP DIFFERENTIAL setting screen press SET four 4 times TEMP DIFF screen with 1 C setting TEMP DIFF screen with 2 C setting Bono Press OK to confirm and return to the normal display mode 7 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT TIME 7 E A Cj 8 Use to enable or disable Back Light dans mm MO TU WE TH FR SA SU Xd 88 88 C The status is displayed as ON or alternatively OFF Use the SELECT button to alternate Once configured press OK to return to normal mode screen To enter DELAY setting screen press SET five 5 SELECT Back Light status times Set UL Back Light symbol Back Light activated ON Use SELECT to alternate Back Light de activated OFF Use SELECT to alternate Press to confirm and return to the normal display mode 8 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT TIME 7 E 4 Cas Cycle Start Delay This feature ensures 5 minute delay between s
11. ystem wil cycles For instance during HEAT mode if the ambient temperature falls on bellow set point minus the temperature differential Ts930 will delay gen en ar add heating for 5 minutes This feature is useful for areas with rapid short duration oscillations in temperature For instance in case window or door is opened for short period of time in TS930 s vicinity 88 88 C The status is displayed as ON or alternatively OFF Use the SELECT button to alternate Once configured press OK to return to normal mode screen To enter DELAY setting screen press six 6 SELECT DELAY status times DELAY symbol DELAY active ON Use SELECT to alternate DELAY disabled OFF Use SELECT to alternate spe e pee Press OK to confirm and return to the normal display mode 9 PHASELINER LTD 17 HERVEY CT 20 SURREY LANE LONDON SW113PT ENGLAND TEL 02072231069 FAX 02078019131 EMAIL SUPPORT PHASELINER CO UK TOUCH SCREEN ROOM THERMOSTAT Display TEMP Adjust TIME Sit E Displayed temperature adjust e 24 Cas This feature is available to allow modification of the displayed m 5 gr temperature Ts930 has been accurately calibrated before dispatch but in WE THER go LS I case displayed temperature is needed to be corrected for instance when ag oc C match has to be made with an old or other local thermostats this feature oo y can be used It will allow