Home
Ecovector HL Installation and User Guide Feb 012
Contents
1. HL 4000 13500 18000 11300 15100 5100 6800 12V 3500 4700 3100 3800 1300 1800 Heat outputs are tested in accordance with BS4856 The temperature of the water in the Central heating system will affect the heat output of this heaters At 60 C assumes a Mean water Temperature of 80 C and a room temperature of 20 C At 50 C assumes a mean water temperature of 70 C and a room temperature of 20 C At 20 C assumes a Mean water Temperature of 40 C and a room temperature of 20 C 5
2. Model HL 1000 12V This model is designed for use in bathrooms and other high humidity areas For these applications it is essential that the heater transformer and fused spur are installed in line with current regulations relative to fixed current equipment in high humidity areas wet rooms and or bath and shower rooms Electrical installations for these heaters must only be carried out by a suitably qualified person All electrical installations must comply with BS7671 1992 and IEE Regulations Check the voltage on the heater is correct for your supply If in doubt consult a qualified electrician The supplied transformer has been designed to fit into a surface mounted or recessed pattress box not supplied similar to those used for shaver sockets 47mm deep The transformer can be mounted horizontally or vertically however it must not be directly above the heater but should be accessible after completion of installation Supply to the transformer must be via a 3 amp fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation HL 1000 12V should not be earthed 4 Isolate the electrical supply and connect the mains side of the transformer to the fused spur 5 Connect between the 12V side of the transformer and the heater using twin core cable fitted to the product Installation Continued Final Assembly 6 Refit the outer casing to the chassis attaching the ea
3. amp Northern contact MT Agencies on 00 353 1 864 3363 In light of our policy of continuous development Smith s Environmental Products Ltd reserve the right to alter specifications without prior notice 8 Feb 2012 Introduction This heater is primarily intended for installation onto a wall at high level The maximum recommended installation height is 2 1 metres to the underside of the heater There is no clearance required above or to the side of the heater Electrical installations for these heaters must only be carried out by a suitably qualified person Model HL 1000 12V This model is designed for use in bathrooms and other high humidity areas For these applications it is essential that the heater transformer and fused spur are installed in line with current regulations relative to fixed current equipment in high humidity areas wet rooms and or bath and shower rooms The transformer has been designed to fit into a surface mounted or recessed pattress box not supplied similar to those used for shaver sockets 47mm deep The transformer can be mounted horizontally or vertically however it must not be directly above the heater but should be accessible after completion of the installation Supply to the transformer must be via a 3 amp fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation Twin core cable is fitted to the product for connection to trans
4. How an Ecovector fan convector works Hot water from your central heating system passes through the heat exchanger transferring its heat to the aluminium fins Cooler air is drawn in by the fan and heated as it passes through the heat exchanger before being Expelled gently back into the room Fan convectors use around 25 less energy than a radiator to heat up a room give a more even temperature spread and achieve the required temperature in much less time This heater includes a selectable low temperature cut out thermostat set by your installer dependant on the type of heat generator that prevents the fan from operating until the central heating system water passing 6 through the heat exchanger reaches 38 for renewable systems or 52C for boiler systems This prevents Ecovector circulating cooler air at start up Smith s eating first a Versatile energy efficient heating ECOVECTOR High Level Fan Convector Heating Models Ensure your central heating system is on the heat output switch set to normal I and the fan HL 1000 HL 1000 12V only switch set to RED Heating Providing the HL2300 HL2900 HL4000 water temperature in the system is more than O i NORMAL 38 C and the thermostat s controlling your i oe eap ral heati i lling for h r a a o on INSTALLATION amp USER GUIDE CODARN If you require a faster warm up move the heat output switch to boost Il moving the h
5. eat BLYEDOT BOOST output switch to O will turn off the heater jitia hiii Dear Installer Air Circulation summer use Ensure central heating is off Set the fan only switch to BLUE and the heat output switch to The following items should be included in the carton either I or Il Ecovector will run to provide a cooling flow of air If the heater is being used in conjunction with a room thermostat the thermostat must be set to maximum e Product complete with cable Fault Finding e Transformer HL 1000 12V only This heater is covered by a free five year parts and labour guarantee Please refer to the fault finding section of the installation guide for advice In the event of difficulty please contact us In the event of items missing or visible damage please on 01245 324560 it will be helpful if you do not disconnect the heater from the central contact us on 01245 324560 We would be most grateful if heating system you would leave this Installation amp User Guide and the Guarantee Registration Card with the owner of the property SS La a BRITISH MADE Thank you for your co operation BRITISH COMPANY Smith s Environmental Products Ltd Blackall Industrial Estate South Woodham Ferrers Chelmsford Essex CM3 5UW Steve Russell Tel 01245 324900 After Sales 01245 324560 Fax 01245 324422 Technical Services Manager E mail info smiths env com Web www smiths env com 3 For Ireland Republic
6. es to the underside of oii the heater For models SCREW FIXING MEAT POINTS POINTS 2900 amp 4000 we recommend that two persons should lift the heater into position 2 1 METRE MAX HEIGHT FROM FLOOR 3 Connect the heating system flow and return pipes to the heater pipe work Do not use soldered fittings to the heater pipe work as the heat generated could damage internal wiring and components We recommend the use of full flow isolating valves The valves should be accessible after completion of the installation We also advise the fitting of an air vent at the highest point on either the flow or the return pipe to remove any air trapped within the system Check for water leaks Vent any trapped air from the heating system Return Flow in Full Flow Service Valves Ceiling Installation Continued Electrical connection Models HL 1000 HL 2300 HL 2900 HL4000 Electrical installations for these heaters must only be carried out by a suitably qualified person All FUSED SPUR Z electrical installation connections must comply with LB BS7671 1992 and IEE Regulations Check the ZZ ZZ voltage on the heater is correct supply for your suppl Za doubt consult a qualified electrician j 4 Isolate the electrical supply and connect the heater electric cable to the spur 3A The fused spur must not be directly above oe the heater but should be accessible after the installation is complete
7. ffect the heat output of this heaters At 60 C assumes a Mean water Temperature of 80 C and a room temperature of 20 C At 50 C assumes a mean water temperature of 70 C and a room temperature of 20 C At 20 C assumes a Mean water Temperature of 40 C and a room temperature of 20 C Fault Finding 1 Fan does not run on any switch setting a Check the power supply is turned on b Check the fuse in the fused spur c Check the wiring connections at the fused spur 2 No heat output on settings I or Il a Vent any trapped air from the system with the central heating system turned OFF b Check the central heating is turned ON c If fitted ensure the room thermostat is calling for heat d Balance the central heating system if installed on the same circuit as panel radiators and increase the circulating pump speed if required e Increase the boiler water temperature In the event of difficulty please contact us on 01245 324560 It will be helpful if you do not disconnect the heater from the central heating system This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance eS Products with this symbol crossed out w
8. former HL 1000 12V should not be earthed Models HL 1000 HL 2300 HL 2900 amp HL 4000 These models must not be installed in bathrooms or other high humidity areas Ecovector is classified as a fixed appliance and electrical connection should be via a 3A fused spur The fused spur must not be directly above the heater but should be accessible after completion of the installation If the pre wired mains cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons This appliance must be earthed For models HL 2900 and HL 4000 we recommended that when securing the product to the wall two persons should lift the heater into position All models These heaters are designed for use on standard two pipe pumped central heating systems Pipes are 15mm for models HL 1000 HL 1000 12V HL 2300 HL 2900 and 22mm for model HL 4000 Either pipe may be used as flow or return These heaters are not suitable for one pipe systems We recommend the use of full flow isolating valves The valves should be accessible after completion of the installation We also advise the fitting of an air vent at the highest point on either the flow or return pipe to remove any air trapped within the system To avoid the possibility of vibration these heaters must be fitted on a flat even surface To conform to Building Regulations Part L Part J in Scotland these Ecovector heaters can be controlled by a remote wall
9. heelie bin cannot be disposed as household waste Old electrical and electronic equipment must be recycled at a facility capable of handling these products and their waste by products If you are purchasing replacement equipment your retailer may offer a take back scheme or will be able to give details of the nearest approved authorised treatment facility Proper recycling and waste disposal will help conserve resources whilst preventing detrimental effects on our health and the environment WEEE Registered Code WEE ED0093VW Smith s Environmental Products Ltd Blackall Industrial Estate South Woodham Ferrers Chelmsford Essex CM3 5UW Tel 01245 324900 After Sales 01245 324560 Fax 01245 324422 E mail info smiths env com Web www smiths env com For Ireland Republic amp Northern contact MT Agencies on 00 353 1 864 3363 In light of our policy of continuous development Smith s Environmental Products Ltd reserve the right to alter specifications without prior notice 6 Installation Please note the guarantee may be invalidated if this product is not installed and used in accordance with this guide 1 Release the outer casing by removing the screws on the underside of the casing CASING RELEASE SCREWS 2 Secure heater to the wall using fixings suitable for wall and level If necessary use packing to compensate for uneven wall surfaces Maximum recommended installation height is 2 1 metr
10. mounted room thermostat Smith s Environmental Products Part No RT002 For further details please contact us on 01245 324560 Smith s heating first l eee Versatile energy efficient heating ECOVECTOR High Level Fan Convector Models HL 1000 HL 1000 12V HL2300 HL2900 HL4000 USER GUIDE Dear Customer We are delighted you have chosen one of our products and trust you are satisfied with the installation We would ask you to take a few minutes to read the User Guide to help you gain maximum benefit from your Ecovector fan convector As with all our products your Ecovector is covered by a free five year parts and labour guarantee and we would be grateful if you complete and return the Guarantee Registration Card to us as soon as possible This will ensure that should you require assistance we can deal with you quickly and efficiently Thank you for your co operation Steve Russell Technical Services Manager 01245 324900 P s Your Ecovector is designed to operate as part of your central heating system in the same way as a panel radiator Providing you leave the heat output switch in either the normal I or boost position II and the fan only switch set to RED your Ecovector will switch on and off automatically with your central heating system Heat output performance continued from page 5 Heat outputs are tested in accordance with BS4856 The temperature of the water in the Central heating system will a
11. rth bonding connector not model HL 1000 12V to the outer Casing EARTH BONDING COMMISSIONING i Turn on electrical supply at the fused spur 2 Set the left hand fan only switch to the blue dot and the right hand heat output switch to Il the fan should run at boost speed 3 Turn on the central heating system 4 Set the room thermostat if fitted to maximum 5 Set the left hand fan only switch to the red dot and the right hand heat output switch to I or Il heat will flow within a few minutes 6 Balance the central heating system if the heater is installed on the same circuit as panel radiators 7 If the installation is working correctly remember to reset the room thermostat if fitted to its normal setting 8 Please leave this installation amp user guide with the property owner for future reference Heat Output Performance It is recommended that the Ecovector High Level model is capable of maintaining The calculated heat losses at normal heat output I enabling the boost settings II to be Used for faster heat up Heat Output At gee a Lee ogee sid uote Btu h Btu h Btu h Btu h Btu h Btu h mon ote sen chen ote tn a HL 1000 3500 4700 3100 3800 1300 1800 same cle ct e ta oda HL 2300 7800 10500 6400 8500 3000 4000 2 9 4 2 2 5 3 5 1 1 1 6 HL 2900 10000 14500 8500 12000 3800 5500 as Lota on ot ol ln