1. using the DAY 1 7 button 7 Move the slider to AUTOmatic position when you have completed steps 6a or 6b The Chronotherm Modulation will now control the room temperature to match your program What do do if do not want to use all 6 temperature changes times The built in program uses only 4 temperature change times as indicated in section How do get started with the built in temperature program The unwanted change times can be deleted by moving the slider to PROGRAM position and holding the appropriate button 1 2 3 4 5 6 for a few seconds The change time will be removed and the display will show dashes instead of time temperature display Deleted temperature change times can be brought back by pressing the appropriate 1 2 3 4 5 6 button and then TEMPerature a or 9 button with slider set to PROGRAM position OPERATING YOUR THERMOSTAT With the operating mode slider in AUTOmatic position Chronotherm Modulation will control the room temperature to match your heating program Manual Override When the slider is in AUTOmatic position the temperature can be adjusted temporarily by pressing the TEMPerature a or button The temperature will return to program at the next temperature change time How do I set the temperature for the whole day To operate as a simple thermostat with one temperature throughout the day move the slider to the MANUAL position Adjust the manual temperature by pressing the T
2. change time can be adjusted to any time up to 02 50 on the next morning so you can maintain evening temperature after midnight NOTE If you attempt to move a change time past the next change time both times will be moved 3 Press the TEMPerature a or W button to adjust the first temperature level Holding the button down will change the temperature quickly The temperature can be set in 0 5 C steps from 5 C to 30 C 4 Press the program 2 button to display the second temperature change time and temperature level for Monday Set these by pressing the or button and the TEMPerature or button 5 The remaining temperature changes for Monday can be displayed by pressing program buttons 3 4 5 and 6 and adjusted by using or button and the TEMPerature A or button if you don t want to use all temperature change times 2 3 4 5 and 6 refer to the next question What if don t want to use all 6 time temperature change times You now have a choice of two methods to set the program for the next day 6 a Press the COPY DAY button to copy Monday s program into Tuesday To set several days of the week to the same program press the copy day button repeatedly 6 b Press the DAY 1 7 button to step the day marker to Tuesday Day 2 The program for Tuesday can be then set as described in steps 2 to 5 1 2 3 4 5 6 7 Programs for Wednesday Day 3 to Sunday Day 7 can be set in the same day
3. the boiler and the thermostat broken Boiler not operating Inertia of the heating system Adaptive Intelligent Recovery action Adaptive Intelligent Recovery action Temperature level set incorrectly Thermostat is powered but receives no information from the boiler There is a short or open circuit between the boiler and thermostat Boiler is in lockout condition NOTE Pressing the you can read the fault code transmitted by the boiler The fault code depends on the boiler type refer to the boiler User Manual for more information Remedy Switch the boiler on Restore power supply Call installer to check the wiring Refer to the boiler User Manual Allow more time for the system to heat up This is normal behavior of your thermostat after installation It takes a few days before AIR function will adjust itself to your house When the temperature level changes upward the thermostat will automatically adjust the temperature level to reach the new required level on time Press the button to check the programmed temperature level Re program the unit if necessary Call installer Call installer to check the wiring Press the reset button to restart the boiler If the symptom appears again call installer immediately
4. EMPerature J or button The manual temperature can be set anywhere from 5 C up to 30 C How can switch the Chronotherm Modulation off Move the slider to the position Thermostat has built in frost protection feature so that if temperature will drop below 7 C it will automatically switch back on to prevent pipes from freezing NOTE The frost protection activation level can be adjusted from 7 C to 10 C using TEMPerature a or button How do I check the programmed temperature In normal operation the temperature displayed is the actual room temperature To check the programmed temperature press the i button once NOTE During upward temperature level change the temperature on the display may not correspond with the programmed level of the current period The reason is that during warm up the thermostat gradually increases the temperature level setting to the next temperature change level During the warm up period the number of the next period is flashing How can I check the outside temperature Press the button twice The outside temperature code T3 will be displayed together with current outside temperature value NOTE This option is available only if the heating appliance provides the outside temperature information to the thermostat I am going on holiday for a couple of weeks How do I save energy when am away 1 Move the slider to the operating position you require on returning from your holiday AUTO
5. USER GUIDE Chnonothown MODULATION Made by Honeywell Chneonothoun MODULATION Ov J Honeywell The Chronotherm Modulation is designed to provide automatic time and temperature control of heating systems These instructions explain how to program and operate your Chronotherm Modulation 42008847 021 R1 Chronotherm Modulation can be used with all OpenTherm compatible boilers The OpenTherm compatible boilers are marked with OT logo shown below A OpenTherm communication Chronotherm Modulation is a programmable thermostat that controls your heating system so that you can have comfortable temperatures when you are at home and energy savings when you are out To ensure that your heating system is operating in most efficient way Chronotherm Modulation not only switches the boiler on and off but also modulates the flame to finely match the heating output of the heating appliance to the current heat demand To maximise energy efficiency Chronotherm Modulation has build in Adaptive Intelligent Recovery function Instead of switching the heating on at the set time every day the controller will delay the start time to the latest possible moment so that unnecessary heating is avoided All you have to do is set the time by which you want to be warm and Chronotherm Modulation will then decide when to turn the heating on CONTROLS LAYOUT These two buttons can also be used when the ew flap is closed Day button
6. allows you to set correct day of the week nE The display continuously shows information about time day of the week and temperature The Energy meter allows you to see the current firing rate of the boiler A radiator or tap symbol is shown when boiler is servicing central heating or domestic hot water o These buttons are used to adjust the temperature level You can operate these buttons also when the flap is closed B Enquiry button is used to display the set room temperature level and the outside temperature only if the outside temperature sensor is connected to your boiler el The holiday function allows setting of a setback temperature for a period of maximum 99 days The same function can also be used as timed program override providing energy savings or extended comfort period These buttons are used to program up to six temperature changes per day gt Slider position defines the operating mode When slider is set to AUTO the Chronotherm will operate according to the program Time adjustment buttons are used for clock and temperature change settings The copy button allows you to copy the time temperature program to the next day SPECIAL FUNCTIONS Modulating control The Chronotherm Modulation continuously adapts the firing rate of the boiler to the required heat demand This results in a very accurate control of the room temperature The modulating control is only possible if the heating appl
7. iance is supporting OpenTherm communications OpenTherm communication The Chronotherm Modulation exchanges information with the heating appliance using OpenTherm two way communication protocol NOTE The amount and type of information that can be displayed as well as appliance specific information codes may vary Refer to the user manual of the appliance for this specific information Optimizing through the intelligent adaptive recovery AIR feature To achieve the required temperature in the house we typically set the on time for the heating system earlier than required In this way we can be sure that we will have the comfortable temperature when we wake up As we never can guess precisely when the heating should come on we tend to stay on the save side setting the on time earlier then required Consequently we have to pay for keeping the house at comfort temperature longer then necessary The Chronotherm Modulation solves this problem completely It checks every day how much time is required to heat up your home Using this data the Chronotherm Modulation calculates the precise moment when to start the heating up the next day to achieve comfort temperature exactly when you want it Consequently you do not have to take the warm up time into account when programming The Chronotherm Modulation activates adaptive intelligent recovery function before every programmed temperature level increase NOTE After installation Chronotherm wil
8. icates if energy is being used for central heating or the domestic hot water if applicable Unique holiday timer function The holiday button allows you to override your normal temperature profile and set the fixed temperature level for a defined time You can set the required temperature for as long as 99 days or as short as 1 hour Intelligent DHW control If you own a boiler that also provides hot water combi boiler then the Chronotherm Modulation can provide additional savings In the FROST PROTECTION or HOLIDAY TIMER function the Chronotherm Modulation will switch off the DHW function or dependant of the appliance will switch to a savings mode In this way the DHW storage will not be kept on a high comfort temperature if this is not necessary If desired it is possible to switch off the DHW during the night setback period Your installer can set this for you NOTE This function is only available if your boiler is suitable for this communication Consult the user manual of the boiler or ask your installer PROGRAMMING YOUR THERMOSTAT Before you start programming You can program your Chronotherm Modulation only if the mains supply of the boiler is switched on the electrical connection to the boiler is made and the thermostat has been mounted on the wall plate When the power for the thermostat is present the display will be activated and the clock will start NOTE Operate the keypad with your fingertips only Sharp objec
9. l require a couple of days to learn how to calculate ON times for a particular house Program up to six time temperature periods per day You have the possibility to set 6 different periods for each day of the week The time temperature periods are marked with numbers 1 to 6 The start time and temperature level for each period is programmable within the temperature setting range of 5 to 30 C Backup during power supply failure Your Chronotherm Modulation operates without batteries The power is supplied through the communication connection In case of the mains power loss a rechargeable backup power supply is sufficient to keep the program and the clock settings for at least 8 hours If the backup supply is exhausted the display will be blank and the individual program will be deleted After the mains supply has been reestablished the factory program will be activated and the display will flash at 12 00 It will take between 10 and 60 minutes dependant on the operating conditions to charge the backup supply The energy meter A a Ih A A JA N A A A I Off Lowfire 40 60 80 100 If the burner of the boiler is energized a bar of flames will be shown on the left side of the display This allows you to check at all times at what firing rate your boiler is operating The percentages in the above graph are indicative only Dependant on the modulation band of your boiler the in between values may vary The radiator or tap symbol ind
10. matic or MANUAL 2 Press the i HOLIDAY button to display the holiday days counter and the temperature 3 Press the or button to set the holiday time 1 99 days An extra flashing day marker shows the day of the week representing the holiday return day Today is counted as the first day of holiday The holiday temperature is set using the TEMPerature a or mP button At midnight of the last day of your holiday the thermostat will return to the normal control as set by the slider position OPERATING YOUR THERMOSTAT CONTINUED I m planning to go out for the weekend would like to save energy when am away but I would like to be sure that my house would be at comfortable temperature on Sunday at 17 00 1 Follow the same procedure as described above to select number of days you will be away 2 Press the l HOLIDAY button a second time to display the holiday return time The time displayed is current time 1 hour rounded off to 30 minutes The return time can be adjusted using the or button in 30 minutes steps 3 At the programmed return time the thermostat will return to the normal control as set by the slider position I m having some friends round for party How can I extend my heating program for a few hours 1 Press the tt HOLIDAY button twice to display the time when you would like to switch the heating off The time displayed is current time 1 hour rounded off to 30 minutes The ret
11. rotect the electronic components from contact with any paint chemicals dust etc that could cause damage to the thermostat Mounting the thermostat on the wall plate 1 Check the wall plate and make sure that the contacts are clean and dry 2 Hang the thermostat in the holes on top of the plate 3 Move the thermostat downwards and push it gently towards the wall until thermostat locks into the wall plate YOUR INDIVIDUAL TEMPERATURE PROGRAM You can use the tables below to record your weekly temperature profile Please note that period 1 must always be programmed MONDAY TROUBLE SHOOTING GUIDE Chronotherm Modulation is able to provide you with fault diagnostic information Please note that the type of data sent from the boiler determines the way the boiler faults are displayed Review the boiler user manual for more information Symptom Blank display The energy meter and radiator symbol are on but radiators are still cold At the programmed time the temperature is too high or too low comparing with programmed values Change of temperature level at the wrong time Temperature too high or too low Display shows day time and amp symbol Display shows only symbol and spanner Ae every 5 SEC Currently displayed segments and spanner symbol are flashing Possible Cause No power from the boiler Mains power loss lasting more then 8 hours Wired connection between
12. ts like pens or pencils can damage the keypad How do I set the time and the day 1 Move the slider to DAY position The time and the day marker will flash indicating that they can be changed 2 Press the or button until the correct time is displayed Each button press will change the time by one minute and stop the display from flashing Holding the button down for a few seconds will change the time slowly at first then quickly 3 Press DAY 1 7 button until the day marker is positioned under the correct day DAY1 is Monday Each button press moves the day marker by one day E S i 4 a Fur ee BE a S How do get started with the built in temperature program Move the slider to the AUTOmatic position The Chronotherm Modulation will now control your heating system using the built in temperature program Monday to Friday How do I set my own temperature program for each day of the week 1 Move the slider to PROGRAM position You will see the first temperature change time and temperature e level for Monday s program the two small arrows rir are displayed only when the programmed T us Lf temperature level is shown The flashing display indicates that you can make changes N 2 Press the or button to adjust the first temperature change time Holding the button down will change the time quickly The change time can be set in 10 minutes steps from 03 00 in the morning The
13. urn time can be adjusted using the or button in 30 minutes steps 2 Adjust your room temperature using TEMPerature or button 3 The thermostat will maintain the set temperature level until specified time At the programmed time it will return to the normal control as set by the slider position How can restore the factory program setting The factory program is restored when the RESET key located at the back of the thermostat is pressed NOTE Before removing the thermostat from the wall review the section MAINTAINING YOUR THERMOSTAT LJ Reset key RESET g pree MAINTAINING YOUR THERMOSTAT Chronotherm Modulation is made from high quality plastics and does not require special maintenance if used under normal operational conditions In case you have to remove your thermostat temporarily for purpose of wall decoration or alterations follow the guidelines below Remove the thermostat from the wall plate 1 Switch off the electrical supply of the thermostat by isolating the heating system 2 Remove the thermostat by pressing the plastic lid with a screwdriver and gently pushing it up This will loosen the thermostat from its wall plate 3 Always protect the contacts in the wall plate from paint or other substances IMPORTANT The wall plate terminals must not be connected to any other voltage sources Applying voltage to wall plate terminals can seriously damage your heating boiler P