Home
B-100 Series Ultraviolet Lamps Operating Instructions - Cole
Contents
1. allow approximately five minutes to reach full brilliance When use is intermittent it is preferable to leave the lamp burning This assures longer bulb life and avoids delay in restarting Restarting does not take place immediately as the mercury vapor within the bulb must cool Delay is typically 4 to 8 minutes Any interrup tion in the power supply such as an excessive drop in voltage will extinguish the arc Restarting typically will be delayed while the mercury vapor cools Full voltage must be restored to permit the arc to strike While mounted on the transformer base the lamp housing can rotate 360 For handheld use detach the lamp housing from the transformer Q 5 l U V ULTRA VIOLET PRODUCTS Replacement Parts List Parts lists are provided for the B 100 lamp models Two parts lists are shown one for the Cool Touch housing lamps and one for the aluminum housing lamps For additional ordering information or an authorized dealer contact UVP Inc in Upland Cali fornia at 800 452 6788 or 909 946 3197 Ultra Vio let Products Limited in England at 44 0 1223 420022 B 100AP B 100AP R AND B 100YP LAMPS 115 VOLT 60 Hz 220 VOLT 50 Hz PART NO PART NAME 34 0054 01 SPOT BULB 36 0043 02 SOCKET MEDIUM BASE 38 0168 01 BEZELAND UV FILTERASSEMBLY 38 0168 02 BEZEL amp YELLOW FILTERASSEM 88 0016 01 BALLAST REPLACEMENT KIT 115V 88 0016 02 BALLAST REPLACEMENT KIT 220V 77 0007 01 B 100AP LAMP HEAD ASS
2. 77 0005 02 LAMP HEAD ASSEMBLY WITH 8ft CORD 220V 77 0005 03 LAMP HEAD ASSEM WITH 20ft CORD 115V 77 0005 04 LAMP HEAD ASSEM WITH 20ft CORD 220V 88 0016 01 BALLAST REPLACEMENT KIT 115V 88 0016 02 BALLAST REPLACEMENT KIT 220V 19 0124 01 LAMP VISOR Accessories The Lamp Visor shields the user s eyes from the UV and directs the UV on the object of analysis Vi sor clips onto the sides of the lamp head Side and front facing views shown Front view Clips a UVP Inc The Lamp Visor shields the user s eyes from the UV and directs the UV on the object of analysis Vi sor shown below is used with Cool Touch lamps Visor clips onto the top of the lamp head Front and side facing views shown Front view Clip Side view PART NAME PART NO 19 0125 01 LAMP VISOR for B 100AP YP models Bulb Replacement and Repairs 1 To replace the bulb first remove the filter assembly a Expand front bezel retainers over circular plastic holders and slide front bezel forward and off b Expand the two silver filter assembly spring clips outward to release filter assembly from lamp body 2 The bulb can be replaced after filter assembly has been detached When replacing the bulb screw bulb in tightly to prevent loosening from heat expansion and contraction during operation Prior to returning any lamps to the UVP factory for repair contact UVP s customer service department to obta
3. B 100 Series Ultraviolet Lamps Operating Instructions These Operating Instructions cover UVP s high intensity UV lamp models 115V and 220V B 100AP B 100AP R B 100YP B 100Y B 100A B 100A R The B 100AP B 100AP R and B 100YP models are manufactured with UVP s Cool Touch plastic hous ing B 100A B 100A R and B 100Y models are manu factured of a durable scratch resistant powder painted aluminum The B 100Y and B 100YP mod els feature a yellow filter Lamp and accessory draw ings and replacement parts lists for each model are included in these instructions General Information for Ultraviolet Inspection Make tests in a darkened area for best contrast Fluo rescence may be bright or dim depending on amount of fluorescing agent present Be careful to distinguish fluorescence from blue light reflection on polished metal surfaces UVP Model UVC 503 Safety Goggles are recommended to eliminate blue haze resulting from eye fluorescence caused by reflected longwave ultraviolet radiation Installation An 8 foot primary and secondary line cord is supplied on all units except the B 100AP R and B 100A R which come with 8 foot primary and 20 foot secondary line cords If the receptacle is not fitted with 3 prong plug use a 2 prong adapter and attach grounding lead to screw center of receptacle plate Operation Turn on off switch on transformer base to ON position for starting Although a cool lamp starts immediately
4. EMBLY 115V 77 0007 04 B 100AP LAMP HEAD ASSEMBLY 220V 77 0007 05 B 100AP LAMP HEAD ASSEMBLY 115V 77 0007 06 B 100AP R LAMP HEAD ASSEMBLY 220V 77 0007 07 B 100YP LAMP HEAD ASSEMBLY 115V 77 0007 08 B 100YP LAMP HEAD ASSEMBLY 220V Bezel amp Filter Assembly Transformer Ballast BENE NRE Accessories The Lamp Funnel for use with the Cool Touch models can be used to direct the UV source directly where you want it eliminating stray UV radiation To attach remove plastic bezel from unit by pulling tabs aparat and sliding bezel out Next insert retaining clips in the four slots of the interior bezel as shown in Section A AA Hold funnel in place and reattach assembled bezel over funnel to unit by pulling tabs apart and snapping into place B 100 Lamp Funnel Retaining Clips Section A A PART NO PART NAME 19 0126 01 LAMP FUNNEL for B 100AP YP models The Finger Guard to keep fingers away from the filter glass easily snaps into place on the face of the Cool Touch lamps A PART NO PART NAME 89 0068 01 LAMP FUNNEL for B 100AP Page 2 B 100A B 100A R AND B 100Y LAMPS 115 VOLT 60 Hz 220 VOLT 50 Hz Note B 100A R NSN 6635 611 5617 ordering number PART NO PART NAME 34 0054 01 SPOT BULB 36 0043 02 SOCKET MEDIUM BASE 38 0168 03 BEZEL amp UV FILTERASSEM 38 0168 04 BEZEL amp YELLOW FILTERASSEM 77 0005 01 LAMP HEAD ASSEMBLY WITH 8ft CORD 115V
5. e warranty period UVP shall examine the inoperative equipment and have the option of repairing or replacing any part s which in the judgment of UVP were originally defective or became so under conditions of normal usage and service No warranty shall apply to any instrument or part thereof that has been subject to accident negligence alteration abuse or misuse by the end user Moreover UVP makes no warranties whatsoever with respect to parts not supplied by UVP or that have been installed used and or serviced other than in strict compliance with the instructions appearing in the operational manual supplied to the end user In no event shall UVP be responsible to the end user for any incidental or consequential damages whether foreseeable or not including but not limited to property damage inability to use equipment lost business lost profits or inconvenience arising out of or connected with the use of instruments produced by UVP Nor is UVP liable or responsible for any personal injuries occurring as a result of the use installation and or servicing of equipment This warranty does not supersede any statutory rights that may be available in certain countries SUVP ULTRA VIOLET PRODUCTS Corporate Headquarters UVP Inc 2066 W 11th Street Upland California 91786 Tel 909 946 3197 or Toll Free 800 452 6788 Fax 909 946 3597 E mail uvp uvp com European Operations Ultra Violet Products Ltd Unit 1 Trinity Hall Farm Esta
6. in a Return Goods Authorization RGA number Page 3 Bulb Standardization For testing uniformity a standard bulb intensity is required A special light meter calibrated for measuring ultraviolet intensity is required to check bulb standardization The UVX Radiometer and UVX 36 sensor or the J 221 UV Meter employ a dense ultraviolet filter and is specifically calibrated to read ultraviolet intensity of 365nm in mW cm from a line source lamp An ordinary light meter will not deliver readings of ultraviolet energy CAUTION 1 Wear hand and eye protection if filter glass is cracked Replace broken filter as soon as possible 2 To avoid electrical shock hazard unplug lamp before servicing 3 Bulb runs very hot allow unit to fully cool before servicing 4 Bulb contains mercury If bulb breaks wear gloves to remove 5 B 100A B 100A R and B 100Y lamp housings become hot during operation and care should be taken not to touch them Lamp handles do not heat even after several hours of use PRODUCT WARRANTY UVP s products are guaranteed to be free of defects in materials workmanship and manufacture for one 1 years from the date of purchase transilluminators are guaranteed for 2 years Consumable and disposable parts including but not limited to bottles tubes and filters are guaranteed to be free from defects in manufacture and materials for ninety 90 days from date of purchase If equipment failure or malfunction occurs during th
7. te Nuffield Road Cambridge CB4 1TG UK Tel 44 0 1223 420022 Fax 44 0 1223 420561 E mail uvpo uvp co uk 81 0093 01 Rev G
Download Pdf Manuals
Related Search
Related Contents
Philips Softone Candle Candle energy saving bulb 872790089715903 Pleasant Hearth FA017SB Installation Guide Side banner Side banner Escaparate para carteles lateral bannière Copyright © All rights reserved.
Failed to retrieve file