Home
Master User Guide - Berkeley Guard Group
Contents
1. The key toggles between the area information and the time date For a full list of Event Log descriptions please refer to the Master User Guide To view the Event Log proceed as follows Enter a valid User code DA D D D Dao you want Lo Arm system Press Do sou want User Menu Press Do sou want Lo View System Log Press de B1 David 2 26 64 8683 E Press 5 to scroll up and down through the Log Disarmed 5 04 06 63 Press to toggle between the area information and the time date Press to display zone text where applicable Areas Di H Press when finished Press to exit the menu The display will return to normal 32 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Event Log Descriptions Log Event Description KSW Active A Keyswitch zone type has been activated zone number RKP MEDICAL A Medical alarm 7 amp 9 has occurred from keypad number RKP FIRE A Fire alarm 4 amp 6 has occurred from keypad number RKP AUD PA An Audible PA alarm 1 amp 3 has occurred from keypad number RKP SIL PA A Silent PA alarm 1 amp 3 has occurred from keypad number DURESS User has entered a Duress Code at a keypad ALARM Active An Intruder alarm signal has been activated for area BELL Active The Bell output has been activated for area REARM LOCK Zone ha
2. Redcare Reset A reset has been performed by the Redcare Key switch Reset A reset has been performed using a key switch User Reset A reset has been performed using a User code EXP Reset A reset has been performed using the input on expander INS177 7 33 Programming the Alarm System Premier Elite Series Master User Guide Remote PC Reset A reset has been performed by the remote download PC FUSE FAIL The Auxiliary 12V Fuse in device has failed AC POWER The control panel has registered a AC Mains failure LOW BAT The control panel has registered a low battery condition POWERED UP System Power Up without doing a factory restart BELL FUSE The control panel Bell Fuse has failed ATS FLT Alarm There is a problem with the telephone line Panel Line Fault The control panel line fault input has been activated Redcare Line Fault The Redcare has detected a line fault Com Line Fault The Com300 2400 or ISDN has detected a line fault Exp Line Fault The Input on expander has been activated COMS FAILED The Communicator has failed to report to the Alarm Receiving Centre DOWNLOAD START An Upload Download has been initiated DOWNLOAD END The Upload Download has finished LOG ALERT 8096 of the Event Log has filled since the last Upload Download DATE CHANGED The control panel Time has been changed TIME CHANGED
3. The display will return to normal 44 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Adding New Users to the System When the control panel is first installed only the Engineer code and the Master User code exist additional users need to be added to the alarm system manually NOTE The factory default Master User code is E E The Master User code is always User 01 and can never be deleted Programming New Users Each User on the system is made up of the following elements 1 2 or 8 3 and 4 these are essential for the code TAG to function correctly items 5 6 and 7 are optional 1 User Number When users are assigned to the system they need to be identified by the control panel Each user is identified as Users 01 02 03 etc User 01 is always the Master User 2 User Code This is a unique 4 5 or 6 digit code number that is assigned to a user the system will allow a mixture of different lengths The User code must be entered at a keypad to operate the alarm system 3 User Areas Any number of areas can be assigned to the selected user Assigning areas to a user determines which areas can be armed disarmed reset etc by that user In addition assigning areas to a user determines which of the area related functions i e omitting zones silent arming etc will be available to that user 4 User Types The User type determines which functions are available to the user i e arming d
4. User 16 Ture is Standard Press These options are only displayed if a Custom User type is selected Press C to scroll through options and press to select the option Letter option IS selected Star option is NOT selected User 16 rtici B DO xoxo ox Accces User Menu PU ok k k k k O Press to select Config and press to edit The following option is only displayed if User Menu has been selected see above Press when finished lest 18 fonti3 Press User 16 Locked bs timer Use keys a to select a timer if required then press User 16 Hame is Press to edit the User name text press when finished For details on programming text please refer to page 51 Press INS177 7 53 Programming the Alarm System Premier Elite Series Master User Guide This option is only displayed if a User with the Door Strike attribute is selected User 18 Door Ctl 2 dotado d Use keys a to select deselect doors then press Add TAG To User 1 Hew Z Imrort Press a to assign TAG to import or to ignore TAG programming Present TAG HOW Present the TAG to the Prox symbol on the keypad A confirmation tone will be heard Press when finished Press to exit the menu The display will return to normal Deleting Users To delete User codes proceed as follows Ensure that Setup Users is selected the display should look like this Setur Users
5. Note The monitoring function must be enabled before it will work INS177 7 5 Overview Premier Elite Series Master User Guide Keypads One or more keypads will be installed throughout the protected premises usually one at each entry exit door The keypads are used to perform all of the system functions i e Arming Disarming etc Premier LCDL Premier LCD Large Display Display Programmable Info LED Prox Reader Normal iab Keys 0686 9006 e Function Keys Display Window Premier LCD LCDP amp LCDL LCDLP amp Premier Elite LCDLP FMK SMK The 32 Character LCD display is used to show the status of the system and to view system data Proximity Reader Premier LCDP amp LCDLP Premier Elite LCDLP FMK SMK Built in Proximity Reader for use with Proximity TAGS approximate range is between 1 and 5 cm Proximity TAGS can be used as an alternative to a Code number LED Indicators Five LED indicators have been provided to indicate the status of the system LED Status Meaning Power On AC mains is present on the control panel Flashing AC Mains is not present the control panel is running on the standby battery Service On The system requires attention contact your installer Off The system does NOT require attention Ready On All zones are secure and the system is ready to be armed Off One or
6. Each area can be Full armed independently from each other all detection devices in the area monitored For instance downstairs and the garage in example 1 areas B amp C could be armed at night allowing access to the upstairs of the house area A NOTE Allofthe areas together form the entire alarm system Example 3 Commercial Premises Office 1 in an office block could be area A office 2 could be area B and office 3 could be area C Each area can be armed and disarmed independently from each other For instance any of the offices in example 2 above could be armed and disarmed to allow access without affecting the other offices NOTE All of the areas together form the entire alarm system Example 4 Office Block The foyer of the office block in example 4 would need to be armed when the last office is armed and disarmed when the first office is disarmed Because the foyer is a global area used by everyone the zones in that area need to be assigned to areas A B and C This ensures that the zone is only recognised by the system when ALL areas A B amp C are armed allowing access to the foyer even if one of the areas is still armed Monitoring This alarm system is capable of reporting Intruder alarms Panic alarms Fire alarms and other types of information over telephone lines to an Alarm Receiving Centre If you accidentally set the alarm off call the Alarm Receiving Centre immediately to prevent an unnecessary response
7. N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A N A INS177 7 65 Notes Premier Series Master User Guide 66 INS177 7 Installation Company Premier Elite Series Master User Guide Installation Company Details Installation Engineer Installation Company Address Telephone Number Installation Date Service Record Date Serviced Comments Engineer Emergency Telephone Numbers For 24 Hour Call Out For Anti Code Reset Control Panel Details Model Elite24 Elte48 Elitese Elte168 Elite640 Location Texecom Designed to Perform Texecom Limited 2012 INS177 7 o os Slo british security industry association
8. Press Do wou want User Menu E Press Dao you want Lo View Event Log Press Dao you want to Set Sustem Date E Press Beni Enter the new date MODO Enter Heu Date gt 2405 81 Press when finished Press to exit the menu The display will return to normal INS177 7 41 Programming the Alarm System Premier Elite Series Master User Guide Overriding the Control Timers The system has Control Timers that may have been programmed to activate outputs arm areas or lockout users at different times of the day Users with access to this option can turn the control timers on and off manually if required To turn the control timers on amp off proceed as follows Enter a valid User code DA D 2 3 Do sou want to Arm Sustem Press Do wou want User Menu Press Do you want Lo View Event Log Press C until the display looks like this Do you want to _ Override Timers Press Timer Controls On are nun e e Use keys a to toggle control timers on and off i e 1 Timer 1 Timer Controls DN are 1 Press when finished Press to exit the menu The display will return to normal 42 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Altering the Control Timers The system has Control Timers Each timer has two ON and OFF times and can be programmed to operate on any day of the week Once configured the timers can be used to
9. The control panel Date has been changed Event Log Hotkeys When viewing the system log there are 9 hotkeys available These hotkeys allow certain events to be found easier without the need for searching The following hotkeys are available a Priority Alarms PA Fire etc Normal Alarms Guard 24hr Entry Exit etc Opens and Closings Arm Disarm etc Omits and Reinstates Zone Omits etc ED Maintenance System Tests Engineer Program etc Tampers Zone Bell Aux etc Test Calls Communicator Active successful etc Entry Exit Entry and Exit Procedures User Codes User codes being used 34 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Changing Your User Code Users with access to this option can change their own User codes User codes are unique to each user and can be 4 5 or 6 digits long NOTE Only the User code that is entered to access the change code menu will be changed Before changing your code it is vital that you memorise or write down the new code you are about to program Failure to remember your code will require an engineer visit to re program a new code for you This may incur a call out charge To change your User code proceed as follows Enter the User code that requires changing Q5 Q CG 3 CG 3 Do vou want Lo Arm Ssstem Press Do wou want User Menu Press Dao you want Lo View Event Lod Press Do wou
10. User BZ Select a user CD D then press Enter User Code Press Do uou want Lo DELETE User 2 Press to confirm deletion of the selected User code Press when finished Press to exit the menu The display will return to normal 54 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Setting up the Part Arms When a Part Arm 1 2 or 3 is selected pre programmed zones are omitted to allow access to certain parts of the building This option allows these zones to be programmed or altered by any User that has access to the Omit menu To set up the Part Arms proceed as follows Enter a valid User code CD CD CD CD the display should look like this Do you want to Arm Sustem Press Do sou want User Menu Press Do wou want tao View Event Log Press Do you want to Alter Part Arms Press Zone B01 Part Front Door Press to select Part Arm 1 Press to select Part Arm 2 Press to select Part Arm 3 For Part Arm 1 gone BBd1 is gt OH Enter a zone number COD CD CD or use the C key to search For Part Arm Z Zone 61 is gt OH Press to turn zone ON or OFF for the selected Part Arm For Part Arm 2 zone Bib is OFF Repeat for other zones Press when finished Press to exit the menu The display will return to normal INS177 7 55 Programming the Alarm System Premier Elite Series Master User Guide Calling a Remote PC This option i
11. Vacation User Menu Door Strike Door Strike Door Strike Call Rem PC Call Rem PC Call Rem PC Duress Code Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close User Config Engineer Master Manager Standard Local Duress Door Strike Vacation Change Code Change Code Change Code Change Code Change Code Chime Zones Chime Zones Chime Zones Chime Zones Chime Zones Change Timer Change Timer Change Timer System Tests System Tests System Tests Setup Users User Setup Eng Access Add Eng Code NVM Locking INS177 7 47 Programming the Alarm System Premier Elite Series Master User Guide User Options 1 This menu defines which options are available to the user when their code is entered This menu is not available to all users Press C to scroll through the options and press to select them or use keys 1 D Letter option IS selected Star option is NOT selected The following options are available A Arming Areas assigned to the selected user can be armed D Disarming Areas assigned to the selected user can be disarmed O Omitting Zones assigned to the same areas as the selected user can be omitted providing that they have the Omit attribute assigned to them R Eng Reset Engineers onl Areas program
12. assigns a Custom User type functions that are not available to them cannot be assigned to the Custom user E Eng Access The selected user can access the Enable Engineer option allowing them to authorise Engineer access or Remote UDL access to the system see page 32 for details A Add Eng Code Engineers only Only Available to Engineers N NVM Locking Engineers onl Only Available to Engineers 50 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System User Name Text Each user can be assigned up to 8 characters of name text This can be beneficial when reading the log as identification of people is made easier Text is programmed in a similar way to mobile phones Characters are selected by pressing the corresponding key the appropriate number of times to select a character on the same key press O to move the cursor along Some control panels also features Predictive text This can be used to make inserting words easier i e when spelling the word COLIN instead of typing 222666555444666 all that you need to do is type 26546 and the word is automatically selected NOTE Itis advised that predictive text be turned off when programming User name text as the library is not comprehensive enough to include all known names The library cannot be edited i e words cannot be added or changed The table below shows the keys to use and the characters that are assigned to them Characte
13. been activated for each area To view activity counts proceed as follows Enter a valid User code DA D D D Do sou want Lo Arm Susten Press C until the display looks like this Do soy want Lo Mieu Act Counts Press Activity A gt Bana Total Count 6665 Use keys a to select an area or use the D key to search To reset the activity counter press Geset Activity B Go Total Court BBE Press when finished Press to exit the menu The display will return to normal 29 INS177 7 Operating the Alarm System Premier Elite Series Master User Guide Sending a Text Message to a Mobile Phone If the control panel has a Com2400 or ComGSM fitted the keypad can be used to send a Text message directly to any of the pre programmed mobile phone numbers To send a Text Message proceed as follows Enter a valid User code AI eo D Dao you want Lo Arm Ssstem Press 5 until the display looks like this Dao wou want Lo Send SMS Text Press Use the keypad to type a message press when finished For details on programming text please refer to page 51 Telerhone Ho 17 0730123456 Press C to select the required telephone number Telerhone Ho 37 07390123456 Press when finished Tue amp amp Mar 661 The display will return to normal 30 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System 4 Programming the Alarm System Introd
14. being entered with a key ring type TAG that is presented to the reader inside the keypad to operate the alarm system Zones A zone is part of the protected premises and may consist of one or more detection devices protecting rooms and points of entry exit e g front door kitchen downstairs windows upstairs bedrooms etc When the alarm system is fully armed all of the zones on the system are monitored Some zones may belong to more than one area such as points of entry exit i e the front door and movement sensor in an entrance lobby These are called global zones because they are assigned to multiple areas A zone that is assigned to more than one area will only be monitored when all of the areas it is assigned to are armed 4 INS177 7 Premier Elite Series Master User Guide Overview Areas An area is a group of one or more zones and would normally be used to split the premises into different sections Each area can be either Full armed or Part armed Example 1 Domestic Premises The entire house could be area A Each area can be Part armed For instance detection devices upstairs i e PIR s could be programmed so that they will not be monitored during a Part arm allowing access to the upstairs of the house at night NorE AreaA forms the entire alarm system Example 2 Domestic Premises The upstairs of a house could be area A the downstairs could be area B and the garage could be area C
15. doors not being omitted are closed and the Ready light is on Enter a valid User code DA D 2 D Do you want Lo Arm system To select areas for full arming proceed as follows Press Select Areas gt RCE 2 lt x Use keys a to select the required area OD selects deselects all Areas Select Areas gt gt Bekk ES Press or to FULL arm The exit tone will sound if silent arm has not been selected Areas in Exit gt RB Leave the premises When the areas have armed the exit tone if sounding will stop The selected areas are now armed Areas Armed gt HB To select areas for part arming proceed as follows Press CDQ D or followed by Then select the area s to part arm as for full arm above INS177 7 17 Operating the Alarm System Premier Elite Series Master User Guide To DISARM the System The Entry time is divided into two sections the Entry time and the 2 Entry time If the Entry time expires an Internal alarm will occur and the 2 Entry time will start If the 2 Entry time expires an Intruder alarm will occur all internal and external sounders Note Itis perfectly normal for the 2 Entry time to be programmed as zero in which case an Intruder alarm will occur as soon as the Entry time expires During Entry To disarm the system proceed as follows Enter the premises via the designated entry point The entry tone will sta
16. normal INS177 7 57 Programming the Alarm System Premier Elite Series Master User Guide Adjusting Speaker Volumes This option is used to adjust the volume level of speakers that are connected to the control panel keypads and expanders To adjust speaker volumes proceed as follows Enter a valid User code CDD Q D Do vou want to Arm Susten Press Do wou want User Menu Press Do you want Lo View Event Log Press 5 until the display looks like this Do ou want Lo Adjust Volumes Press Panel Volume evel 6 Press O to select a Panel Keypad or Expander speaker Kewrad Bi Volume Leuel 4 Press then 1 D to enter a volume level 1 Minimum 8 Maximum Press to hear the new volume level Kewrad Bi Volume Level gt 7 Press to accept the new speaker volume Repeat for other speakers Press when finished Press to exit the menu The display will return to normal 58 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Printing the Event Log If a printer or terminal is connected to the control panel this option can be used to print out events from the systems Event Log To print the Event Log proceed as follows Enter a valid User code eoo D SR Do you want Lo Arm Sustem Press Do wou want User Menu Press Do you want to View Event Log Press C until the display looks like this Do sou want Lo Print Ev
17. options will depend on the control panel being used some control panels do not support all of the features and also the type of user on that system If a function or option cannot be selected it may be that it is not assigned to that user see page 47 for details To access the Arming User menu proceed as follows The display will normally show the time amp date The top line is programmable Tue 86 Mar 20683 To access the Arming menu enter a valid User code D D D D or present your tag Dao you want Lo Arm System To select the User menu Press Do wou want User Menu To access the User menu Press Dao you want Lo View System Log Press to exit either menu The display will return to normal 12 INS177 7 Premier Elite Series Master User Guide Using The Alarm System The Arming Menu 18 24 55 Wed oi Enter A Valid User Code Do uou want to Arm System Do sou want to Qu Part Arm System Do uou want to Gud Silent Arm Do uou want to Gx Cancel Exit Do wou want to Disarm System Do uou want to Cus Use Hnti code Do uou want to m Omit Zones Do uou want to Gud View Zone Status Do uou want to GC Omit z4Hr Zones Do uou want Lo Set Chime Areas Do uou want to View Act Faults Do uou want to View Act Faults Do sou want Lo C 2 Send SMS Text Do sou want Lo C05 Exit Menu Do
18. uou want User Menu eset 18 24 55a Wed Bi The User Menu Do sou want User Menu Do sou want to View Event lod Do sou want Lo BD Change Code Do sou want Lo SD Edit Chime Zones Do uou want Lo Ga Do System tests Do sou want to Do Walk Test Do sou want Lo C6 Enable Engineer Do sou want to Set Sustem Time Do sou want Lo Set System Date R 9 Do soy want to Override Timers Do sou want to Alter Timers Do sou want to Setur Users Do sou want to Alter Part Arms 9 NN Do sou want to Call Remate PC Do sou want to Alter Hol Dates o Do sou want to Adjust Volumes o Do sou want Lo Print Event Lod Do sou want to Edit Phone Ho Do sou want to Exit Menu R 16 24 55a Wed Bl INS177 7 13 Operating The Alarm System Premier Elite Series Master User Guide 3 Operating the Alarm System Introduction The normal day to day operations of the system are carried out using the Arming menu i e arming disarming omitting zones etc NOTE The range of available functions and options will depend on the control panel being used some control panels do not support all of the features and also the type of user on that system Not all functions are available to all users If a function cannot be selected it may be that it is not assigned to that user see page 47 for details If no keys are
19. want Lo Change Code Press Enter Heu Code Enter a new 4 5 or 6 digit User code 2 DA 2 D Enter Heu Code aes Press to accept the new code Press to exit the menu The display will return to normal INS177 7 35 Programming the Alarm System Premier Elite Series Master User Guide Setting up Zones for Chime Users with access to this option will be able to select which zones cause the internal sounders to chime every time they are activated Chime would normally be used on a front door back door exit button etc NorE Zones will only cause the internal sounders to chime if Chime is turned on see page 24 for details on turning Chime on and off To setup zones for Chime proceed as follows Enter a valid User code DA D D D Dao you want Lo Arm Ssstem Press Do wou want User Menu Press Do sou want to View Event Log Press Do soy want Lo Edit Chime Zones Press E zone Bal Silent Front Door 3 Enter the zone number CD CD CD or use the CZ key to search zone 015 Silent Back Door gt Press to select Chime Once for Chime 1 twice for Chime 2 etc Zone B15 Chime Z Back Door A Repeat for other zones if required Press when finished Press to exit the menu The display will return to normal 36 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Testing the Sounders and Strobe Users with access to this option
20. Code i e 5624 Enter the Anti code that has been given to you DA DE 2 D Quote gt 4281 Rerly gt 3624 Press If the Anti code is correct the keypad will chime to indicate that the system has been reset and the display will return to normal 22 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To OMIT Zones It is possible to exclude omit individual zones when arming i e if a zone is in fault Users with access to this function can only omit zones that have been programmed as Omittable NOTE He zone can be omitted there will be a star to the right of the zone number Only zones that have the Omit attribute assigned to them can be omitted A star will appear to the left of the zone number to indicate that the zone has been selected for omitting All omitted zones will be automatically reinstated the next time the system is disarmed unless programmed otherwise To re instate zones manually simply follow the instructions again However when the key is pressed this time the zones will be re instated To omit zones when arming proceed as follows Enter a valid User code 2 DCD CD and press Zone Bal Secure Front Door gt Enter a zone number CD CD D or use the CZ key to search Zone l Active Lounge Detector gt Press to omit the selected zone Zopekl Dutt iue is Omitted ZonevBism Secure Lounge Detctor gt Repeat for other zones
21. E ARM FAIL gt Enter a valid User code DA D DCE D The internal and external sounders will stop the external strobe will continue to flash and the number of the zone that caused the arm fail will be displayed in this case Zone 2 gore BB Active Bedroom Window Enter a valid User code 2 gt DC D and press Tue G Mar 2061 The arm fail has now been cleared INS177 7 19 Operating the Alarm System Premier Elite Series Master User Guide To SILENCE an Alarm When an alarm occurs on the system the internal and external sounders will normally sound for a pre programmed time normally 15 minutes NOTE f you were not present when the alarm activated the internal and external sounders may have already stopped but the external strobe will still be flashing When alarm information is being displayed pressing the key will slow down the display and also allow manual scrolling through the events To silence an alarm proceed as follows The alarm will be sounding and the display will look something like this Tue amp amp Mar 061 Enter a valid User code DA D DCE D The internal and external sounders will stop and the number of the zone that caused the alarm will be displayed in this case Zone 2 zone Ba Alarm 14 46 64e Tue 86 The Hallway Pir The alarm now needs to be reset To DISPLAY the cause s of System Alerts Alarms When silencing an alarm or unsetting the system after an ala
22. Master User Guide Premier Elite 24 48 88 168 640 INS177 7 Designed to Perform CE Texecom Overview Premier Elite Series Master User Guide 1 Overview 4 INTO UC ON eT 4 Keypads O NON 6 Emergency Keys ur ee aes redd a nn Ale eerie 7 THE QUICK ArmiKeys oe rre A ve ae eed 8 Keypad Lock ssssss 8 Alert Reset and Service Messages 9 Fault Messages nana reat eee ia 10 Zone Faults During Arming eeeeeeeeeeeeeeeeeeeee nn 11 Other Messages Displayed during Armming nnns 11 2 Using the Alarm System nrnnnnnsnnnnnnnnennnnnnnnnnne 12 uge e E 12 3 Operating the Alarm System luiprifuilim To FULL Arm the System cccssecseeeseeeseeeesteeseneeseeseneeseeennesseaeenteeseneeneeeseneeseeesaneessanentees T PART Arm the System 2 erret ete pereas eed EES ENEE To ARM Individual Areas dee dana To DISARM the Systom 2 Eer ae During Entry When Not in Entry To CANCEL the Exit Mode tn treno exis du eer ben teer aab een TO CLEAR an Anim Faille ann trs in incidan To SILENCE aj Ala M r nea lides iden aia To DISPLAY the cause s of System Alerts Alarms To RESET After an Alarm E Eed EE USER ROS D e aeaaee a AAA EPA ENGINEER R686lt 1 drehte regedit e pe a
23. any zones active e g door ajar open window etc the internal sounders will bleep repeatealy fault tone and the display will show the zones that are active gore DI Active Front Door The fault tone will stop and the exit tone will resume when all zones are secure If it is necessary to leave a zone open then it must be omitted see page 23 for details NOTE lfanactive zone cannot be secured then it may be in fault in this case contact the alarm company immediately Arm Fail Failing to Arm If the exit procedure is started and zones are still Active at the end of the exit procedure an Internal alarm will occur internal sounders only and the strobe light on the external sounder will flash NOTE f this occurs the arm fail must be cleared and the zone in fault identified before the system can be armed see page 19 for details on clearing an Arm Fail The Ready LED To help prevent faults during arming a Ready light has been provided The Ready light works as follows e ifthe Ready light is ON then all zones are secure and the system is ready to be armed e If the Ready light is OFF then one or more zones are active either secure or omit these zones before proceeding e If the Ready light is FLASHING then the system has zones with the Force Omit attribute that are active check these zones before proceeding Other Messages Displayed during Arming Zones on Soak Test If any zones have been put on soa
24. ar option is NOT selected The following options are available U User Menu The selected user has access to the User menu However the selected user will only have access to options assigned in User Config see page 50 for details E Eng Program Engineers onl Only Available to Engineers D Dual Code The selected user can only access an area when a second User code with the Dual Code attribute and also assigned to the same area is entered Dual Code users will also activate the 15 and 2 Code output type V Vacation The selected user is enabled the first time it is used to disarm the system and can be used as many times as required However it will be automatically deleted the first time that the User 01 code is used to disarm Vacation users will only be deleted by the Master user once they have been used on the system S Door Strike The selected user will activate any outputs programmed as Door Strike whenever their codes are entered R Call Rem PC The selected user has access to the Call Remote PC option allowing them to initiate a call to a remote Upload Download PC see page 56 for details C Duress Code The selected user will activate any outputs programmed as Duress whenever their codes are entered O Open Close The selected user will report open disarm and close arm events to an Alarm Receiving Centre every time they arm or disarm INS177 7 49 Programming th
25. asion the zones will be re instated To omit 24 Hour zones proceed as follows Enter a valid User code DA D DE 3 Dao you want Lo Arm Ssstem Press Dao wou want Lo Omit 24Hr Zones Press zone D I Secure Front Door gt Enter a zone number CD CD CD or use the C4 gt key to search gone Bi5 Secure Back Door gt Press to omit the selected zone gone B15 Secure is Omitted ZOnehlD Secure Back Door gt Repeat for other zones Press when finished Press to exit the menu The display will look like this ZdHe Omitted Tue amp amp Mar 061 The selected 24 Hour zones are now omitted 26 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To SELECT Areas for Chime When a zone is enabled for Chime the Keypad will generate a chime tone every time the zone is activated Users with access to this function will be able to turn Chime on and off for selected areas Zones within an area can be individually programmed for Chime in Edit Chime Zones see page 36 for details NoTE Only areas that have been programmed for Chime can be selected A star means the area can be selected and a dot means the area cannot be selected Pressing will select deselect all areas Pressing will toggle between areas A to H and to P To select an area for Chime proceed as follows Enter a valid User code DA D D 7 Do you want Lo Arm ssstem Press Enable Ch
26. automatically arm or disarm areas lockout User codes and control outputs etc Users with access to this option can program the Control Timers To program control timers proceed as follows Enter a valid User code gt D D D Do sou want to Arm Sustem Press Do wou want User Menu Press Do you want Lo View Event Log Press 5 until the display looks like this Press Control Timer 1a H Do wou want to Change Ctl times is On at 88 8 Use 5 to Select a Control Timer from 1 to 8 Control Timer Za is On at 88 m8 Enter the first On time 24 Hour format OH 3 cH MD M5 Control Timer Za is On at 212135 Press when finished Timer Za On Dass Use keys a to select the On days SUN to SAT i e a and Sunday and Monday INS177 7 43 Programming the Alarm System Premier Elite Series Master User Guide Timer Za On Dass Press when finished Control Timer Za is Off at 12 08 Enter the first Off time 24Hour format D cD MD M5 Control Timer Za is Off at 21410 Press when finished Timer Za Off Dass Use keys a to select the first Off days SUN to SAT i e and Friday and Saturday Timer Za OFF Dass Press when finished Control Timer od is On at 88 68 Repeat programming for the timers Second On times On days Off times and Off days Repeat for other Control Timers Press when finished Press to exit the menu
27. can test various system outputs to ensure that they operate correctly These include any outputs that have been programmed for specific operations i e bringing on floodlights sounding buzzers etc The internal sounders speakers and the external sounder can also be tested to ensure that they are operating correctly Note Any outputs that have been left On will be turned Off when the menu is exited To test the Sounders and Strobe proceed as follows Enter a valid User code 2 2 D 3 Dao you want Lo Arm Ssstem Press Do ou want User Menu Press Do sou want to View Event Log Y Press Do you want Lo Do System test ig D Press Push YES to test i HOFF Bell is A Press to select the BELL test Press 1 D to select the STROBE test Press to select the SPEAKER test Press to select the USER OUTPUTS test Press to select the DISPLAY test i e 2 for Speaker test Push YES to test Sreaker OFF Press to test the selected output Press env when finished Press to exit the menu The display will return to normal INS177 7 37 Programming the Alarm System Premier Elite Series Master User Guide Walk Testing the System Users with access to this option can walk test any of the zones on the system to ensure that they operate correctly A walk test can only be performed when the system or area is disarmed 24 Hour zones except Fire and Tampers are disabled during walk test all
28. d when ONE OR MORE zones have been left OFF omitted i e the landing or a bedroom NOTE The system is only Part Armed when zones are omitted using the Part Arm procedure omitting zones manually see page 23 for details is not classed as Part Arming The bottom line of the display is programmable for each Part Arm Your Installer may have programmed the system so that it can be part armed by just pressing C D or followed by if this is the case then there is no need to enter the User code below To part arm the system proceed as follows Ensure that the premises are secure all windows and doors not being omitted are closed and the Ready light is on Enter a valid User code DA D D D Arm Susten Press Do wou war Evening arm Use keys a to select the required part arm Do wou wanti Bedtime arm Press to arm normally or press to arm silently The exit tone will sound if silent arm has not been selected Areas in Exit gt H Leave the protected area When the system has armed the exit tone if sounding will stop Bedtime Hrm H PART ARMED Tue amp amp Mar 061 The system is now part armed 16 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To ARM Individual Areas If the system has been set up for multiple areas each area can be individually selected for FULL or PART arming as required Ensure that the premises are secure all windows and
29. d by battery There is normally no reason for anyone except an installer or service person to have access to the control panel The keypad is used to control the alarm system and to display its status via the English text display The keypad also provides audible feedback each time a key is pressed Each keypad will be mounted in a convenient location inside the protected premises near the designated points of entry exit Users Users of the alarm system will be assigned a unique 4 5 or 6 digit User code User codes are used to arm and disarm areas to which they are assigned Some User codes can also access additional options such as system tests and omitting zones To access the system a valid User code must be entered if a mistake is made whilst entering a User code simply re enter the correct code the system may have been programmed so that too many incorrect code entries will cause a Tamper alarm or lock the keypad out The User code may not allow access to certain functions i e if the code is only allowed to arm and disarm area A it will not be able to arm or disarm other areas on the system Most User codes can arm and disarm areas assigned to them from any keypad on the system However Local Users will only be able to arm and disarm areas assigned to them from keypads assigned to the same areas As well as or instead of a code users of the alarm system can be assigned a Proximity TAG Proximity TAGS replace the code number
30. debe ANTI CODE Resta NENNEN dE EECH To OMIT Zones To Turn CHIME On and Off EEN To VIEW the Status Of Zones tien nee armee vo Enna a dona vasa ua rena tresse TO OMIT 24 HOUP ZONES DICE CD TO SELECT Areas for Chime siccwcsiectcesstsiecsceedesecscevscteceesescsesescsecsssterserses vecesavesesereustesesvsestevsunee To VIEW Activity Faults To VIEW Activity Count sinci ceccctec Sending a Text Message to a Mobile Phone 4 Programming the Alarm System eee eeeeeeeeeeeeerrn 31 Introduction Pas 31 Viewing the Event Log eee ee esee e sees esee en eese essen n item e satin eae a nnne sse ae dabis nsadi nos 32 Event Log Descrtptions sise 33 2 INS177 7 Premier Elite Series Master User Guide Overview Changing Your User Codoe 5 1 NN is 35 Setting up Zones for Chime nn 36 Testing the Sounders and Strobe nn 37 Walk Testing the System senem nnns nn strains senes ann sten nnns 38 Enabling Engineer ACCESS cccsssccssseessseesesseeeesseneeessneeeeseeeseseneessseesassaeeeeseneeeseneeseseseeeeses 39 Setting the System Time 1 aiaosa aitita reser A 40 Setting the System Date ccescssssseeecsteeseneeseeeseneeneeesanesseeenneeseneesneeseaeestessaneeseaeenneeseneeas 41 Overridi
31. e Alarm System Premier Elite Series Master User Guide User Config This menu defines which menu options are available to the user when their code is entered This menu will only be displayed if a Custom User type is selected AND User Menu User Option U is enabled see page 49 for details Press C to scroll through the options and press to select them or use keys 1 D Letter option IS selected Star option is NOT selected The following options are available C Change Code The selected user can change their own User code Z Chime Zones The selected user can access the Edit Chime Zones option allowing them to select which zones chime when activated see page 36 for details T Change Timers The selected user can access the Override Timers see page 42 for details Alter Timers see page 43 for details Alter Part Arms see page 55 for details Alter Hol Dates see page 57 for details and Edit Phone No see page 60 for details menu options S System Tests The selected user can access the System Tests option allowing them to walk test zones activate the external sounder etc see page 37 for details U Setup Users The selected user can access the Setup Users option allowing them to alter existing users or assign new users see page 45 for details However users cannot assign User types to the system that have a higher access level than themselves Also if a user
32. e an intruder alarm system in which it is installed to comply with the requirements of security grade 2 amp 3 of EN50131 1 EN50131 3 and EN 50131 6 and is suitable for installation in any indoor environment Environmental Class 2 Inhibit Functions For Alarms and Tamper is controlled by the Swinger shutdown counter which is Engineer programmable and is defaulted to 3 Minimum Logical Keys 10 000 for 4 digit code 100 000 for 5 digit code 1 000 000 for 6 digit code8 The number of disallowed codes 0 NOTE Dependant on the use of the Black Listed codes function available via Wintex a maximum of 16 codes may be Black Listed Warranty All Texecom products are designed for reliable trouble free operation Quality is carefully monitored by extensive computerised testing As a result the control panel is covered by a two year warranty against defects in materials or workmanship As the control panel is not a complete alarm system but only a part thereof Texecom cannot accept responsibility or liability for any damages whatsoever based on a claim that the control panel failed to function correctly Due to our policy of continuous improvements Texecom reserve the right to change specification without prior notice Premier Keypads and Expanders are protected by UK amp International Registered Design Registered Design Number 2089016 and 3004996 Premier amp Premier Elite are trademarks of Texecom INS177 7 61 Installa
33. eed as follows Enter a valid User code DA D DCE D Do sou want Lo Arm Sustem Press Do sou want to View Zone Status Press zone Bal Secure Front Door 3 Enter a zone number CD CD CD or use the LS gt key to search gone B18 Secure Lounge Detector Pressing will make the zone chime every time it is activated an Arrow will appear to the right of the zone number to clear the Chime press again Pressing will display the zone text Every time the selected zone is activated its status will be displayed and the keypad will chime if selected zone Bib6 gt Active Lounge Detector gt zone B18 Secure Lounge Detector gt Press when finished Press to exit the menu The display will return to normal INS177 7 25 Operating the Alarm System Premier Elite Series Master User Guide To OMIT 24 Hour Zones It is possible to exclude omit or include 24 Hour zones whilst the system is disarmed to allow access to an area Users with access to this function can only omit zones that have been programmed as Omittable NOTE f the zone can be omitted there will be a star to the right of the zone number Only zones that have the Omit attribute assigned to them can be omitted A star will appear to the left of the zone number to indicate that the zone has been selected for omitting To re instate the zones simply follow the instructions again However when the key is pressed on this occ
34. ent Log Press Humber of events gt Bass Enter the number of required events Q Q Q2 e Humber of events 0506 Press to print the Event Log Press to exit the menu The display will return to normal INS177 7 59 Programming the Alarm System Premier Elite Series Master User Guide Editing a Mobile Telephone Number If the control panel has been programmed to send SMS text messages to a mobile phone in the event of an alarm occurring etc this option allows the mobile telephone numbers to be programmed To edit a Phone Number proceed as follows Enter a valid User code eg 5 Qo D Do you want to Arm Sustem Press Do wou want User Menu Press Do you want to View Event Log Press C until the display looks like this Do uou want Lo Edit Phone Ha Press Telerhone Ho 1 CAH HOT CHANGE Press C to select the required number Telephone Ho 3 Press to edit the number Press when finished Press to exit the menu The display will return to normal 60 INS177 7 Premier Elite Series Master User Guide Installation Records 5 Specifications European Standards Conforms to European Union EU Low Voltage Directive LVD 73 23 EEC and Electro Magnetic Compatibility EMC Directive 89 336 EEC The CE mark indicates that this product complies with the European requirements for safety health environmental and customer protection This equipment is designed to enabl
35. ew Alert Reset and Service Messages System Alerts When an alarm or fault condition exists on the system the keypad will display a warning message Tue 86 Mar 20083 In order to display the alarm or fault condition s that generate this alert enter your user code a scrolling display will show all alarm fault conditions on the system When alarm information is being displayed pressing the SCROLL key will slow down the display and also allow manual scrolling through the events The messages that can be displayed are shown in Reset and Service messages below and in Fault Messages on page 10 Reset and Service messages When the system requires a reset service the display will show one of three messages These messages can also be accessed at any time from the normal display NorE These messages may have been changed by the installer and may contain the telephone numbers of the installer or the Alarm Receiving Centre To display the reset service messages proceed as follows Press followed by 1 D to view the Service message Call Hlarm Ca for Service Press followed by to view the Reset message Call Engineer to Reset System Press followed by to view the Anti code message Call ARC Reset System Press to exit from the messages The display will return to normal INS177 7 9 Overview Premier Elite Series Master User Guide Fault Messages Mains Power OFF Tue 86 Mar 2661 There is a Main
36. if required Press when finished Do you want Lo Arm Sustem Continue to arm the system as normal The selected zones are now omitted the omit light will be on INS177 7 23 Operating the Alarm System Premier Elite Series Master User Guide To Turn CHIME On and Off The system can be set up so that activating opening certain zones will cause the internal sounders to chime This would normally be used on a front door exit button etc NorE Zones will only cause the internal sounders to chime if they are selected for chime see page 36 for details on selecting which zones chime Once a zone has been selected for chime the Chime facility can be manually turned on and off as required NoTE The system can also be programmed to automatically turn Chime on and off under certain conditions i e certain times of the day door left open etc If no zones have been programmed for chime then turning Chime on and off will have no effect To turn CHIME On proceed as follows Press The Chime tone will sound To turn CHIME Off proceed as follows Press The Fault tone will sound 24 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To VIEW the Status of Zones Users with access to this feature will be able to check the status of each zone on the system to see whether it is in Fault Secure Tamper Shorted or Inactive To view the status of zones proc
37. ime on pA e Use keys a to select deselect areas i e UM and Areas A B and C Enable Chime on gt BRC lt Press when finished Press to exit the menu The display will return to normal INS177 7 27 Operating the Alarm System Premier Elite Series Master User Guide To VIEW Activity Faults If any zones with the Activity attribute have not been activated within a certain time period an activity fault will be displayed at the time of arming Users with access to this function will be able to view the activity faults NOTE The system may have been programmed so that an activity fault will not allow arming If this is the case the system can only be armed once the zone in fault has been activated forced walk test Only zones with the Activity attribute that have not been activated will be shown To view activity faults proceed as follows Enter a valid User code DA D DE 3 Do you want Lo Arm system Press C until the display looks like this Do you want Lo View Act Faults Press zone Bal Secure Front Door 8 Press C to scroll up and down through the zones Press when finished Press to exit the menu The display will return to normal 28 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To VIEW Activity Counts Users with access to this menu will be able to view the number of times that zones with the Activity attribute have
38. isarming resetting etc and also which options the user can access i e Setup Users System Tests etc 5 User Time Lock This option allows the selected user to be denied access to the system at different times of the day and days of the week When a Control Timer is assigned to a user the User code will not allow access to any functions during the timers On period 6 User Name Text Each user can be assigned up to 8 characters of name text The name text is displayed whenever a code is entered and also when reading the log making identification of people using the alarm easier 7 Door Control This option would normally be used for access control Users are able to open unlock doors that are assigned to their user code 8 Proximity TAG As well as or instead of operating the alarm system with a 4 5 or 6 digit code number it is also possible to operate it by presenting a Proximity TAG to the keypad this requires a Proximity keypad INS177 7 45 Programming the Alarm System Premier Elite Series Master User Guide User Types The User type determines which functions are available to the user i e arming disarming resetting etc and also which options the user can access i e Setup Users System Tests etc The following User types are available 1 Master Master users can arm disarm omit zones silence alarms and reset their assigned areas In addition Master users can access all User menu options Master users ca
39. k test by the installing company the message will have to be acknowledged before the system will arm Keyfob Low Battery If you are using a Smartkey to arm and disarm your system and a Low Battery condition is detected you will have to acknowledge this every time you arm the system until the battery or fob has been replaced NOTE Depending on the configuration of your system it may not be possible to disarm with a code therefore a low battery condition on your fob should be reported to the installation company as soon as possible Failure to do this may result in unwanted activations which may have further repercussions INS177 7 11 Using The Alarm System Premier Elite Series Master User Guide 2 Using the Alarm System Introduction The operation of the system is divided up into two sections the Arming menu and the User menu To access the Arming menu enter a valid User code Q 5 Q 5Q 5Q D Once in the Arming menu various functions can be selected by using the O key Once a function has been selected press to access that function To access the User menu press followed by es Once in the User menu various options can be selected by using the 5 key Once an option has been selected press to access that option To exit from either menu press the key and the display will return to normal The diagram on page 12 shows both menus and the functions and options available NoTE The range of available functions and
40. med as Engineer Reset can be reset after an Alarm has occurred a Local Arming The User can only arm areas that the keypad is assigned to d Local Disarm The User can only disarm areas that the keypad is assigned to or areas that are in entry or alarm provided that the code has that area assigned to it Y Auto YES After a code is entered pressing to confirm the next action is not required F Disarm First If an area is armed and the user enters their code the Disarm option is displayed first The following attributes are only available on the Premier 24 NOTE Some ofthe following options may not always be selectable or de selectable T Lock TAG PGM2 The Users TAG is disabled whenever PGM2 is active C Lock Code PGM3 The Users code is disabled whenever PGM3 is active default during the Entry mode U Lock User PGM4 The Users TAG and Code is disabled whenever PGM4 is active default Control Timer 4 O Open Close The selected user will report open disarm and close arm events to an Alarm Receiving Centre every time they arm or disarm 48 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System User Options 2 This menu defines which options are available to the user when their code is entered This menu is not available to all users Press to scroll through the options and press to select them or use keys CO D Letter option IS selected St
41. more zones are active Flashing The system has zones with the Force Omit attribute that are active On The system is armed can also be programmed for other indications The system is unarmed can also be programmed for other indications One or more zones are omitted No zones are omitted 6 INS177 7 Premier Elite Series Master User Guide Overview Keys Keys a to These keys are for entering User codes or programming data Yes amp No Keys amp The YES key is used to accept actions and the NO key is to cancel actions or edit data Omit Key This key is used to omit zones see page 23 for details Chime Key This key is used for turning the chime facility on and off see page 24 for details and also for turning the Exit tones on and off during the exit mode Part Key This key is used to part arm the system see page 16 for details It can also be used to do a Quick part arm if this feature is enabled Area Key This key is used to arm or disarm particular areas see page 17 for details It can also be used to do a Quick arm if this feature is enabled Reset Key This key is used to exit from a menu or to reset the system see page 21 for details Scroll Key This key is used to scroll through the various menus and options and also to slow down the display if itis scrolling through alarm information too fast Menu Key This key is used to select the Arming o
42. n also change their own User codes and assign new users to the system The Master user will also activate any output programmed as Door Strike 2 Manager Manager users can arm disarm omit zones silence alarms and reset their assigned areas In addition Manager users can access all User menu options except Setup Users Manager users can also change their own User codes 3 Standard Standard users can arm disarm omit zones silence alarms and reset their assigned areas In addition Standard users can access all User menu options except for Setup Users System Tests and Change Timers Standard users can also change their own User codes 4 Local Local users behave the same way as Standard users However Local users can only arm and disarm areas assigned to their codes from keypads assigned to the same areas 5 Duress Duress users behave the same way as Standard users However Duress users will activate any outputs programmed as Panic Alarm or Duress whenever their code is entered 6 Arm Reset Only Arm Only users can only arm and reset their assigned areas Reset Only users can only disarm following an alarm and then reset rearm the alarm again 7 Door Strike Door Strike users have no access to User functions or Menu options However Door Strike users will activate any outputs programmed as Door Strike whenever their code is entered 8 Vacation Vacation users behave as Standard users However Vacation users a
43. ndineer Access Disabled Press to enable disable Engineer access Endineer Access Enabled Press Press to exit the menu The display will return to normal INS177 7 39 Programming the Alarm System Premier Elite Series Master User Guide Setting the System Time The alarm system has a real time clock that is used to date and time stamp events that are recorded within the system Log Users with access to this option will be able to set the Time on your alarm system To set the System Time proceed as follows Enter a valid User code DA D DE 3 Do sou want Lo Arm Sustem Press Do sou want User Menu Press Dao you want Lo View Event Log Press Do ou want to et Sustem Time Wa ur Press Enter Heu Time gt 12 28 BST Enter the new time 24 Hour format H gt OH 3 MD M5 Enter Heu Time gt 21 45 BST Press to change between BST and GMT Enter Heu Time gt 21 45 BMT Press Press to exit the menu The display will return to normal 40 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Setting the System Date The alarm system has a real time clock that is used to date and time stamp events that are recorded within the system Log Users with access to this option will be able to set the Date on your alarm system To set the System Date proceed as follows Enter a valid User code DA D D 3 Dao you want Lo Arm System
44. ng the Control Tlmere eege ENEE den 42 Altering the Control T Imers a reiecit ENEE Ee EEN pas 43 Adding New Users to the System inner 45 Programming New Users iii 45 User Types cce trees hte RR e EEUU 46 Available Options RE 47 Us Options ERREUR 48 User Options HH 49 User en le DEE 50 User Name TeX esiosan dadea aaant a autera Programming Users paina it eed Aa Deleting Users a a A ted ae Setting up the Part Arms d eundi Bcc Altering the Holiday Dates eeeeeeeesiseeeeeeeeeeeee nennen nennen nnnn natnra cercana cera Adjusting Speaker Volumes 1 treten it nung id Printing the Event Log in ee daba nennt nn nnnna hu tasara knak rra Editing a Mobile Telephone Number 5 Specifications nnsnnnnnnnnnnnnnnnnnnnnnnnne 61 European Standarde E 61 Inhibit FUNCTIONS a uice erra creer enne cerno ep apa nas rre n o cci dran Cra oa ara dias sa kae pe aras asser tie ne sans este cass en 61 Minimum Logical Keys eeeeeeeeeeeseeeseee nennen nenne nennen entera senem anran asas inna asses satanas ann 61 K E 61 6 Installation Records nnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnns 62 INS177 7 3 Overview Premier Elite Series Master User Guide Introduction The alarm system consists of a control panel one or more keypads and various detectors and sensors The control panel is normally mounted out of sight in a cupboard etc and houses the system s electronics and stan
45. owing Audible PA buttons Silent PA buttons etc to be tested To perform a walk test proceed as follows Enter a valid User code DA D D D Dao you want Lo Arm Ssstem Press Do sou want User Menu Press Dao you want to View Event Log Press Gu Do uou want Lo Do Walk test Press Walk test areas Ron A Use keys a to select an area for walk testing Walk test areas gt Ath Press to start the walk test HOME Every time zones are activated the keypad will chime zone _14Active Lounge Detector gt Press eno when finished Press to exit the menu The display will return to normal 38 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Enabling Engineer Access If Engineer access either on site or via remote download computer has been programmed as User authorised this option must be used to allow the Engineer access to the programming menu Users with access to this option can authorise Engineer access NOTE Engineer access is only permitted for 4 hours after it is enabled after which it will automatically be disabled again To enable Engineer access proceed as follows Enter a valid User code 25 5 DE 3 Do sou want to Arm Sustem Press Do sou want User Menu Press Do sou want to View Event Log Press 5 until the display looks like this Dao wou want Lo Enable Engineer Press E
46. pressed the display will return to normal after a pre programmed time The table below shows the various functions available Arming Menu Function Arm System Part Arm System Silent Arming Cancel Exit 00008 Disarm the System 00 Use Anti code Omit Zones View Zone Status Omit 24Hr Zones Set Chime Areas View Act Faults View Act Counts Send SMS Text User Menu 14 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To FULL Arm the System The system is FULL Armed when ALL zones are ON not omitted NOTE Your Installer may have programmed the system so that it can be set by just pressing Grea if this is the case then there is no need to enter the User code below To arm the system proceed as follows Ensure that the premises are secure all doors and windows closed etc and the Ready light is on Enter a valid User code DA D DCE D Do you want Lo Arm Sustem Press to Silent arm if required Do uou want to Silent Arm Press to arm The exit tone will sound if silent arm has not been selected Areas in Exit gt A Leave the premises When the system has armed the exit tone will stop if sounding Tue amp amp Mar 2061 The system is now armed INS177 7 15 Operating the Alarm System Premier Elite Series Master User Guide To PART Arm the System The system is PART Arme
47. r A D G J M P W X Y Z Move Cursor Backspace delete Copy Text Paste Text Predictive Text Key a E Upper Lowercase Predictive text and Clear Screen INS177 7 51 Programming the Alarm System Premier Elite Series Master User Guide Programming Users To Program Users proceed as follows Enter a valid User code CDD D Q Do you want Lo Arm Sustenm Press Do sou want User Menu Press Do you want Lo View Event Log Press 5 until the display looks like this Do ou want Lo Setur Users Press Setur Users User Gz Select a user CD Q or use the 5 key to search Setur Users ill User i8 To Program a Code To Assign a TAG Press Press Enter User Code Add TAG To User rs lzHewu Z ImrFort Enter the new Press C1 2 Q2 D or User code G OQ QOO to exit The code can be 4 5 Present the TAG to The Prox symbol Press on the keypad A confirmation tone See next page will be heard 52 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System From Previous page User 16 areas gt gt Poo 4 Use keys a to select deselect areas then press User 18 Ture is Hot in Use Use keys a to select a User type or use the ES key to search Refer to page 45 for a list of available User types
48. r details To reset the alarm proceed as follows Enter a valid User code gt D 2 3 Do you want Lo Arm system Press The external strobe will stop the system will chime and the display will return to normal ENGINEER Reset If the system has been programmed to be reset by an Engineer following an alarm activation you will still be able to silence the alarm by entering a valid User code see page 20 for details NoTE The system cannot be armed again until the alarm has been reset To reset the alarm proceed as follows Contact the telephone number on the display if programmed or the telephone number on the last page of this User Guide INS177 7 21 Operating the Alarm System Premier Elite Series Master User Guide ANTI CODE Reset If the system has been programmed to be reset using an Anti Code following an alarm activation you Will still be able to silence the alarm by entering a valid User code see page 20 for details NoTE The system cannot be armed again until the alarm has been reset To reset the alarm proceed as follows Enter a valid User code DA D D 3 Press RESET for Anti code Press The display will show a random code number i e 4281 Quote 4281 Rerly gt Contact the telephone number on the display if programmed or the telephone number on the last page of this User Guide and quote the random code number You will be given a 4 digit Anti
49. r User menu Emergency Keys In case of emergency the alarm system can provide three immediate emergency alarms by pressing and holding two specific keys Press Keys UK Response Export Response Da Panic Alarm PA Fire 8 Fire Panic Alarm PA 8 Medical Medical NOTE The emergency keys can be enabled disabled for each keypad on the system The Panic alarm can be programmed for either audible or silent operation The Panic alarm can be programmed for either instant or delayed operation INS177 7 7 Overview Premier Elite Series Master User Guide The Quick Arm Keys The Quick Arm keys allow the system to be armed without having to enter a User code first Note The Quick Arm keys will only work if the keypad has been programmed to allow arming in this way To FULL arm the system press area To PART arm the system press 1 D or followed by Car Keypad Lock The keys on the keypad can be locked to prevent unwanted access to the system Notre The Emergency keys will NOT operate with the keys locked To Lock the keys press and together To Unlock the keys press and together again ICONS UK English English 000000066 88008900 EE Bo gH LED s Power S Ready Armed Info OK Ready Omit Ba Service C gt T 8 INS177 7 Premier Elite Series Master User Guide Overvi
50. re automatically deleted the first time that the Master User code User 01 is used to disarm the system NoTE A Vacation user is only deleted by the Master user after it has been used to disarm the system at least once 9 Custom Custom users can access any functions and User menu options that have been assigned to them in User Options 1 or 2 and User Config This flexibility allows new User types to be created that have their own unique set of characteristics Any number of Custom users can be assigned to the system and each one will respond differently depending on the functions and features that have been assigned to them 46 INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Available Options The table below shows the options that are available to each user NOTE All users that have access to the Arming Menu have the ability to View Zone Status Set Chime Areas View Act Faults and View Act Counts All users have access to the User Menu have the ability to View Event Log Adjust Volumes and Print Event Log User Options 1 Engineer Manager Standard Local Duress Door Strike Vacation Arming i Arming Arming Arming Arming Arming Disarming Disarming Disarming Disarming Omitting Omitting Omitting Omitting Eng Reset Disarm First Disarm First Disarm First Engineer Manager Standard Door Strike
51. rm the number of the zone s will be displayed on the keypad If several zones were triggered the display will scroll through each in turn After noting the cause of the alarm the system can be reset as described in RESET After an Alarm below System Alerts When the system has faults to display or has not been reset after an alarm condition the display may show SYSTEM ALERTS Enter a valid User code DA D 2 3 Any alarms or faults will be displayed If several fault or alarm conditions have been triggered the display will scroll through each in turn After noting the cause of the alarm or fault the system can be reset as described in RESET After an Alarm below NorE Some action may be required to clear the cause of the alarm or fault in order to successfully reset the panel 20 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To RESET After an Alarm If the display shows SYSTEM ALERTS follow the steps described in To DISPLAY the causes of System Alerts above before attempting to reset USER Reset Once the alarm has been silenced see above the system will need to be reset NOTE Ifthe system has been programmed to be reset by an Engineer pressing will not return the display to normal if this is the case see ENGINEER Reset page 20 for details The system may have been programmed to be reset by Anti code if this is the case see ANTI CODE Reset page 20 fo
52. rt n Entra gt Enter a valid User code Q Q2 Q Q The entry tone will stop 14 46 04e Tue G The system is now disarmed When Not in Entry To disarm the system proceed as follows The display will look something like this 14 46 dr Tue B6 Enter a valid User code DA 5 2 3 Do you want to Disarm System Press 14 46 64e Tue 86 The system is now disarmed 18 INS177 7 Premier Elite Series Master User Guide Operating the Alarm System To CANCEL the Exit Mode Once the exit mode has been started you should leave the premise immediately however if for some reason you decide not to leave the exit mode must be cancelled To cancel the exit mode proceed as follows Enter a valid User code 2D D 2 D Dao you want Lo Cancel Exit Press The exit tone will stop Tue amp amp Mar 061 The exit mode has now been cancelled To CLEAR an Arm Fail When the system tries to arm with zones active open the internal sounders will sound and the external strobe will be flashing to indicate a problem For details on preventing an Arm Fail condition please refer to page 11 NoTE lf you were not present when the arm fail occurred or you do not clear the arm fail the internal sounders will continue to sound and the external strobe will continue to flash To clear the arm fail proceed as follows The alarm will be sounding and the display will look something like this RIC
53. s failure the keypad may chime every minute enter a valid User code or press to stop the chime The display will automatically clear when mains is reapplied There is a signal path fault the keypad may chime every minute enter a valid User code or press to stop the chime The display will automatically clear when line fault clears The signal path may be telephone line or mobile phone network Battery Fault Tue 86 Mar 2661 ATS Path Fault Tue 86 Mar 2641 There is a fault with the standby battery the keypad may chime every minute enter a valid User code or press to stop the chime Contact your alarm company immediately Tue 86 Mar 2661 There is a Tamper fault the alarm will sound enter a valid User code to silence the alarm this fault cannot normally be cleared Contact your alarm company immediately Service Feauired Tue 86 Mar 2661 The service timer has expired indicating that the system requires a service or a fault has occurred that requires attention the system can normally still be used Contact your alarm company to advise Area Secured Tue 86 Mar Zee The keypad has been disabled to prevent unauthorised access This normally occurs when a zone programmed as Security Key is active the display will automatically clear when the zone returns to normal Activity Fault Tue 86 Mar 2661 A zone with the Activity attribute has not been activated within the activity time period this ma
54. s re armed after causing an alarm CROSS A Verified Cross Zone Alarm has occurred from zone USER User has entered their code AREAS EXIT The Exit mode has been started for area ARMING FAILED A Exit Error Arm Fail has occurred on area AREAS ENTRY The Entry mode has been started for area ARMING SUITE Area Arm Suite was used to arm the system ARMED WITH L F The system has been armed with a Line Fault condition present AREA Armed Area has been armed AREA Disarmed Area has been disarmed PART Armed Area has been Part Armed TIME Armed Area was armed automatically using one of the timer controls TIME Disarmed Area was disarmed automatically using one of the timer controls DEFERRED The arming mode was deferred for area ALARM ABORT An Open After Alarm Abort has occurred for area REMOTE Armed Area was armed using the Wintex UDL software REMOTE Disarmed Area was disarmed using the Wintex UDL software QUICK Armed Quick Arm from keypad RECENT Armed Area has been armed recently RESET AREAS Area have been reset using keypad following an Intruder alarm Engineer Reset A reset has been performed using an Engineers code Anti Code Reset A reset has been performed using the Anti code reset procedure Remote Reset A reset has been performed using the Remote Reset input
55. s used to initiate a call to a remote uploading and downloading computer To send a call to a Remote PC proceed as follows Enter a valid User code CDD D Q Do sou want to Arm System Press Do wou want User Menu Press Do wou want Lo View Event Log Press until the display looks like this Do you want to Call Remote PC Use keys 4 to select a Call Back number i e Call Back number 2 Press to start the call back Press to exit the menu The display will return to normal INS177 7 Premier Elite Series Master User Guide Programming the Alarm System Altering the Holiday Dates This option is used to alter the programmable Holiday Dates These dates can be used to prevent the control timers from operating on certain dates of the year bank holidays etc or to only operate on certain dates reminders To alter Holiday Dates proceed as follows Enter a valid User code ES Cr Q Q Do you want to Arm Sustem Press Do wou want User Menu Press Do you want to View Event Log Press 5 until the display looks like this Do sou want to Alter Hol Dates Use 5 to Select a Holiday Date from 1 to 8 Holiday Date 3 gt DD DD D0 Press then enter the new date gt CD MD MD gt D Holiday Date 35 24712702 Press to accept the new Holiday Date Repeat for other holiday dates Press when finished Press to exit the menu The display will return to
56. tion Records Premier Elite Series Master User Guide 6 Installation Records Areas Exit Entry Entry Bell Bell Abort Mo Description Time Time1 Time2 Delay Duration Time Sec Sec Sec Min Min Sec Sec Sec Sec Min Min Sec Sec Sec Sec Min Min Sec Sec Sec Sec Min Min Sec Sec Sec Sec Min Min Sec Sec Sec Sec Min Min Sec Sec Sec Sec Min Min Sec Keypads RKP Keypad Keypad Quick Emergency Keys No Location Area Arm PA Fire Med 62 INS177 7 Premier Elite Series Master User Guide Installation Records Zones Zone No Zone Description Zone Zone Type Areas Zone Omit Part Arms 1 2 3 Tick Zones Included in Part Arms INS177 7 63 Installation Records Premier Elite Series Master User Guide Zone Zone Zone Zone Zone Part Arms No Description Type Areas Omit 1 2 3 Tick Zones Included in Part Arms 64 INS177 7 Premier Elite Series Master User Guide Installation Records User Codes Type Default New Code Time Lock Master 5678 N A N A N A
57. uction Advanced operations of the system are carried out using the User Menu i e System Tests Assigning Users etc NOTE The range of available functions and options will depend on the control panel being used some control panels do not support all of the features and also the type of user on that system Not all options are available to all users If an option cannot be selected it may be that it is not assigned to that user see page 47 for details If no keys are pressed the display will return to normal after a pre programmed time The table below shows the various options available User Menu Option View Event Log Change Code Edit Chime Zones System Tests Walk Test Enable Engineer 060 Set System Time Set System Date Override Timers Alter Timers Setup Users Alter Part Arms Call Remote PC Alter Hol Dates Adjust Volumes Print Event Log Edit Phone No 99999990 INS177 7 31 Programming the Alarm System Premier Elite Series Master User Guide Viewing the Event Log Users with access to this option can view the system Event Log This log records all of the events that occur on the system i e Users entering their codes to arm or disarm the system alarms failures to arm etc along with the time and date on which they occurred NOTE The down key moves you to the previous event backwards in time and the up key moves you forwards again
58. y be caused by an obstruction view the zone status to find out which zone has not activated then activate the zone to clear the fault Fuse Bloun G Mar 2081 A fuse has blown the alarm will sound enter a valid User code to silence the alarm this fault cannot be cleared Contact your alarm company immediately Hrea Failed Tezt Tue 86 Mar Z amp Bi Zones that have been placed on test by the engineer have failed the test the system can still be used Contact your alarm company to advise Remote Keyrad is now LOCKED out Too many invalid code attempts have caused the keypad to lock out The keypad will normally remain like this for 5 minutes Time Armina gt A Areas are being armed using one of the control timers enter a valid User code to defer the arming Alarm Engineer Working On Site The alarm engineer has logged into the programming menu and is working on site this message will clear when the engineer logs off or the system is armed NOTE When alarm information is being displayed pressing the SCROLL key will slow down the display and also allow manual scrolling through the events 10 INS177 7 Premier Elite Series Master User Guide Using The Alarm System Zone Faults During Arming Before attempting to arm the system ensure that the premises are secure all doors and windows closed etc and the Ready light is on If an attempt is made to arm the system with
Download Pdf Manuals
Related Search
Related Contents
Singer S16 User's Manual FA200C Installation Manual Bedienungsanleitung Copyright © All rights reserved.
Failed to retrieve file