Home
CELLROUTE-GSM (AC) Installation & User Guide
Contents
1. You will hear an acceptance tone once the digits have been dialled CELL ROUTE GSM AC 7 telecomew Troubleshooting e First Things to Check If No Operation 1 Check that Power is connected 2 Check that SIM card is installed correctly 3 Check that the telephone is connected correctly e LED Status 1 2 4 5 6 If NO LED s are lit e Check for mains power If RED LED is flashing with high pitch Interrupted Tone when handset lifted e No SIM connected e SIM has a PIN set and this is not recognised in Cellroute memorv e SIM has been swapped with a SIM that has a PIN set which is not Recognised in Cellroute memorv e Network lock is set to on with incorrect network SIM connected If NO RED LED with low pitch Interrupted Tone when handset lifted e Cannot detect a network signal See Reception is poor If RED LED flashing at 100ms on off e CellRoute is networked locked and does not recognise the networked SIM Installed GPRS unit Oniv RED amp GREEN LEDs flash 5 times e CellRoute is Initialising RED amp GREEN LEDs flashing on off at the same rate e Missed call Indicator e Dial Tone Is Not Heard 1 pA Check that Power is connected to the AC mains socket Check L E D status Both power and signal strength LED should be lit 3 Check SIM lock is deactivated 4 5 Check if connected to a PBX that the CellRoute works with a Check that the telephone connected is wo
2. ETS 06 10 Enhanced Full Rate ETS 06 50 06 60 06 80 3V Integral Omni directional Antenna With SMA connector for external Antenna option Physical Interfaces Analogue 11 An SMA male connector 3V Small card retained under rear panel 2 X LED indication for Power Transmission Status Approvals CE Certification to R amp TTE directive 1999 S SEC GSM Certifications e ETS 300 607 1 Digital Cellular Telecommunications Systems e EN 301 419 1 Global System for Mobile Communications e ETS 300 342 1 Radio Equipment and Systems CELL ROUTE GSM AC Technical Specification telecomru Features Overview High Ringer Equivalence POTS Interface Supports up to 4 additional extensions Highly compatible POTS user interface Caller Line ID Presentation Bellcore Additional GSM network features may be available Subject to network availability and support SIM lock for asset protection For details contact your service provider Network Lock for asset protection For details contact your service provider Remote Software Upgrades Remote Antenna facility Off hook Howler Gain adjustment on microphone 1 gt 5 Gain adjustment on speaker 1 gt 5 Inter digit timer setting Power Supplies Primarv 110 240Vac 47 63Hz Phvsical Specifications Height 150mm Width 122mm Depth 42mm Weight 460gm Operational Temperature Range OC to 45C
3. by 1 sets lowest volume 5 sets highest volume You will hear an acceptance tone once the digit has been dialled CELLROUTEGSMAC W i Getting Started telecomrm Ansvvering Incoming calls Lift handset and call is connected Missed Call If both L E Ds are flashing simultaneousiv this is identifving a missed call Switching Off The CellRoute When switching off the CellRoute GSM vou must unplug the power cord from the AC mains outlet Network Lock The CellRoute GSM has a network lock feature This is a network securitv function For further details please contact vour service provider SIM PIN Lock The CellRoute GSM has a SIM card PIN lock feature This is a SIM card securitv function For further details please contact vour service provider Confidence Tone It is possible to turn confidence Tone ON or OFF Confidence Tone ON dial O 45614 Confidence Tone OFF dial 0 560 Vou will hear an acceptance tone once the digit has been dialled Ringing Cadence It is possible to adjust the ringing cadence for incoming calls to cell route To change dial O 8 1 4 1 USA 2 UK 3 SPAIN 4 ETR You will hear an acceptance tone once the digits have been dialled Inter digit Timer It is possible to set an inter digit timer between dialled DTMF digits To change dial O 58nnn n 100ms increments Example 0 5860 would set 6 seconds 10 1 second 50 5 seconds default 100 10 second 250 25 seconds maximum
4. 0023 Roger Lew mgton CellRoute GSM AC W telecomrm I ntroduction Thank vou for the purchasing the Cell Route GSM terminal Note Data features are not available on the RJ45 port If you require Data features thev are available on the GPRS version The CellRoute GSM incorporates e CellRoute GSM terminal 1 e Antenna 2 e RJ11 Telephone connector 3 e L E D Indicators 5 e Power Connection 6 e External Antenna Connection amp Switch 7 CELL ROUTE GSM telecomrw Getting Started Setting up the terminal Remove the CELLROUTE GSM from the packaging and proceed as follows Warning To avoid damage do not connect power until you have inserted the SIM card e Install the SIM card Making sure the PIN lock is deactivated if applicable Install the CELLRoute GSM in preferred location following guidelines e Connect Power to the CELLRoute GSM using Power Supply Provided e Connect a telephone to the CELLRoute GSM e Check Signal Strength e Make a test call Installing the SIM card Slide open the SIM cover Slide back the SIM door and lift it up Slide the SIM into the SIM door making sure that the clipped corner of the SIM card lines up with the clipped corner of the SIM Holder Close the SIM door Slide SIM door to lock the SIM in place Then replace SIM cover CELL ROUTE GSM AC Getting Started telecomru Location Of Cell Route For best reception locate your Ce
5. CellRoute GSV ja i Il ue x ANU Installation amp User Guide Version 03 Feb 2008 telecomrwv ii CELL Route GSM AC Document Control Version Jan 2005 1 t release of document Jan 2006 Notices amp WEEE Directive symbol added Feb 2008 Inter digit timer added Oct 2009 Added Inbound Outbound line reversal Added AT command if detection of no SIM aa Notices Emergency Calls This terminal operates using GSM signals which cannot guarantee connection in all conditions Therefore vou should never relv solelv on the terminal equipment for essential communications such as medical or emergency services No responsibility is assumed by TFM for the use or reliability of the CellRoute GSM when used in a situation or with other equipment not supplied or specified bv TFM TelecomFM shall accept no liabilitv for anv error or damages of anv kind resulting from the use of this document or the equipment it relates to The wording in this document mav change from time to time Please refer to the TelecomFM web site WWW telecomfm co uk for the latest release Declaration of Conformity tala COM Applicant Telecorri MH Ltd Address B95 Plymouth Reed Slough SL1 ALF Berkshire U K Product Call Route This equipment complies with the European R amp TTE Llirect hee no 19997 S ERC on radio and telacommunication terminal agui pment Telec omFn4 Signed May 20
6. he GSM Network the Red LED will come back on Connecting CellRoute GSM to a PBX Via the RJ11Socket When connecting to a PBX you are required to connect to the RJ11 socket Note The CellRoute GSM must be connected to a Trunk Port on the PBX Connecting CellRoute GSM to a Telephone s Via the RJ 115ocket When connecting a telephone you are required to connect to the RJ11 socket Making a test call Make a test call with the PBX Phone connected to the CellRoute GSM On completion of dialled digits you will hear a confidence tone indicating the call is successful Pressing the key after the dialled digits results in a faster dial up The RED LED will start to flash when the handset is lifted on the telephone Indicating signal Strength Once the call is connected the RED LED will flash for 45 seconds indicating signal strength then stop leaving both RED and Green LED lit Number of flashes Signal strength in dB None Poor lt 81dB gt 81dB amp lt 67dB gt 67dB amp lt 59dB It is possible to Set Incoming amp Outgoing volumes on CellRoute Outgoing volume adjustment on microphone To adjust the microphone level e Lift the receiver e Dial 0 6 e Dial 1 to 5 followed by 1 sets lowest volume 5 sets highest volume You will hear an acceptance tone once the digit has been dialled Incoming volume adjustment on speaker To adjust the Speaker level e Lift the receiver e Dial 0 3 e Dial 1 to 5 followed
7. llRoute GSM close to a window or on an external wall within a minimum of 330mm from any mertallic object The unit must be a minimum of 1 meter from any other sensitive electronic equipment DO NOT locate in direct sun light or near anv direct heat source Mounting the CellRoute GSM and Power Supplv Bracket U TOOT Using the template provided mark location and fix with screws supplied Mount the Power Supply bracket within 1 meter from the CellRoute GSM Connecting to PBX telephone or Computer e Connect the PBX Trunk Port into the RJ11 socket labelled telephone Connect your telephonets into the RJ 11 socket labelled telephone Connecting the power Supply e Connect the Mains lead into the power supply unit then into the AC outlet e Connect the power cord from the power supply unit to the CellRoute GSM Connecting external Antenna if required To activate the external antenna move the antenna switch to the up position and screw the external antenna into the SMA connector provided External Internal B Antenna r Antenna SMA SMA Connector Connector w CELL ROUTE GSM AC telecomrw Getting Started Powering Up CellRoute GSM On power up the RED and GREEN LEDs will flash 5 times The Green LED will come on and remains on The RED LED will light up for approximately 10 seconds and then go out for approximately 10 seconds Once the unit has logged onto t
8. rking correctly standard telephone connected w CELL ROUTE GSM AC telecoMem Troubleshooting e Noise Is Heard during a Call This maybe due to poor signal strength or the unsuitable location of the CellRoute GSM It is recommended that CellRoute GSM is positioned a minimum of 1 meter away from other telephones and other electronic devices e Reception is Poor The CellRoute GSM comes with a built in antenna However If you are experiencing problems with poor reception check that you are getting adequate signal strength This can be achieved by moving the CellRoute GSM to another location for examples move closer to a window or higher up in the building In some locations your Coverage area may require a higher gain external antenna for optimal Call clarity and performance An external 3Db antenna is supplied with the unit see Connecting external Antenna Contact your service provider for advice on other types of external high gain antenna that can be connected to CellRoute GSM Call Control Line Voltage Loop Current Line impedance Ring Voltage Ring Load CLIP Transmit Power Speech Codecs SIM Card Antenna Telephone GSM Antenna SIM Card Indication Telephonv Interface DTMF 48v on hook 40mA off hook 600 ohm complex 70Vrms REN 4 Bellcore FSK GSM Interface E GSM 900MHz GSM 1800MHz GSM Phase 2 Class 4 2W for E GSM 900 MHz Class 1 1W for GSM 1800MHz Half Rate ETS 06 20 Full Rate