9454/9455 Installation and User Guide
Contents
1. Enter the command number Enter one or more digits to give the new program Press ENTER The panel will give a double bleep to show that it has accepted the command If you enter the command incorrectly the panel gives a single tone Default Settings When delivered from the factory the panel is programmed as follows Zone 1 Entry Route Part Set zone Zone 2 Normal alarm active in Part Set Omit allowed Zone 3 Normal Alarm active in Part Set Omit allowed Zone 4 Normal Alarm active in Part Set Omit allowed Zone 5 Normal alarm Zone 6 9455 only Normal Alarm Zone 7 E E Part set User code 1234 6 of 12 496331 Issue 1 9454 5 Engineering Program Commands Engineering Program Commands To change Key in Followed by ENTER Default Zones 1 5 6 01 05 6 0 Not used 1 Normal Alarm 2 24 Hour Alarm 3 Entry Route 4 9454 Dbl knock 9455 Fire zone 5 9454 Chime 9455 Dbl knock 6 9454 Part set zone 9455 Chime 7 9455 Part set zone OMIT Omit Allowed Entry exit zone options 07 0 Reset to none 5 9454 Chime 6 9454 Part set zone 9455 Chime 7 9455 Part set zone Programmable Output 11 18 9454 PIR set latch 29 9454 Shock sensor reset 19 9455 PIR set latch 28 9455 Shock sensor reset 39 9455 Tamper alarm function 49 9455 System part set Engineer Access 20 Any 4 digit code 7890 Bell output type 21 0
2. 9454 SAB 9455 normally open 1 9454 SCB 9455 normally closed 7 9454 9455 Internal sounder 22 1 Follows strobe 0 Follows bell PA 30 0 Audible Alarm 1 Silent Alarm SIN System Reset 31 0 Customer Reset 1 Engineer Reset S Abort facility 32 0 Disabled 1 Enabled Keypad PA 33 0 Disabled 1 Enabled System status 34 0 LEDs ON 1 LEDs OFF 7 9455 Y 9454 Exit Mode 35 0 Timed or Terminated 1 Final Door Set Control panel ET and 36 RKP I P function 9455 only 0 Exit terminator 1 Keyswitch set Rearm 40 0 Never 1 Once 2 Twice 3 Three times 4 Always 496331 Issue 1 7 of 12 Engineering Program Commands 9454 5 To change Key in Followed by ENTER Default External sounder delay 41 0 Nil y 1 1 5 mins 2 3 mins 3 5 mins 4 10 mins 5 15 mins 6 20 mins 7 No duration Ext sounder duration 42 0 Nil 1 1 5 mins 2 3 mins v 3 5 mins 4 10 mins 5 15 mins 6 20 mins 7 No duration Entry Time 43 0 Continuous 1 10s 2 20s y 3 30s 4 60s 5 90s 6 120s Exit Time 44 0 Continuous 1 10s v 2 20s 3 30s 4 60s 5 90s 6 120s CSID code 50 nnnn key in four digit code Part Set Entry Exit 60 0 As Final Exit v 1 Normal Alarm Part Set Entry Response 61 0 As
3. Entry Route 1 Start Entry Timer Vv Part Set Exit Mode 62 0 As Full Set 1 10 Second Set y 2 Instant Set Part Set Alarm Response 63 0 Local No comms y 1 Full Alarm Engineer Log 8of 12 90 1 see earlier events 3 to see more recent events ENTER to quit log 15 events max 496331 Issue 1 9454 5 Refresh NVM To change Keyin Followed by ENTER Default External Sounder 91 ENTER to stop test Strobe 92 ENTER to stop test Internal Sounder 93 ENTER to stop test Test keypad LEDs 94 ENTER to stop test Programmable output 95 ENTER to stop test Walk Test 97 ENTER to stop test Load Factory Defaults 98 Leave Engineering Mode 99 Refresh NVM System Memory Chip The 9454 5 control panels have a Non Volatile Memory chip which retains all programmed information and access codes If the system suffers a total power failure the NVM will retain all information and the panel will only require powering up and resetting However if the end user forgets the user access code or the installer wants to return the panel to the factory pro grammed settings continue as follows 1 Power down the control panel mains and battery 2 Find the RST pins located to the middle of the control pcb 3 Place a small screwdriver blade to short between the RST pins on the 9455 also use a short length of wire to short out the Kick Start pins With the blade still acros
4. z O SERVICE TAWPER a ENTRY EXIT power Zone 1 pay Zone 2 FULL O Zone 3 PART C O Zone 4 panic tO oo SERVICE FAULT C Zone 1 programmed as 24 hours has activated Enter the user code to stop the sounder s Close the 24 hour door or circuit Check the fault light has extinguished then enter the user code to clear the system Either an exit fault or alarm activation has occurred in zone 1 Enter the user code twice to clear the system 496331 Issue 1 The power light flashes 11 of 12 Full Set System Part Set System Unset Reset System Omit zone Omit 24 hr zone Change User code Read Log Chime On Off Bell Test Walk Test 12 of 12 9454 5 User Commands 1 ENTER User code 2 ENTER User code User code 1 or 2 ENTER User code OMIT zone number repeat OMIT zone number for other zones as required OMIT ENTER User code zone number zone number for other zones as required 4 ENTER Old code Old code the system beeps twice New code the system beeps twice 5 ENTER User code 1 to read earlier events 3 to read later events ENTER to leave the log 7 ENTER User code 8 ENTER User code 9 ENTER User code ENTER to end the test 496331 Issue 1
5. 9454 9455 Installation and User Guide Compatible Equipment 9425 Remote Keypad 9040 Internal Sounder 660 Speech Communicator 8440 4 Channel Minicom 496331 Issue 1 1 of 12 9454 5 Introduction The 9454 and 9455 are fully programmable control units designed to meet the requirements of larger domestic and medium commercial installations A basic system comprises a main control unit complete with built in keypad The control unit houses the system electronics power supply battery and remote signalling device if fitted A numeric keypad and row of indicators LEDs on the outside of the unit allow the user and installer to operate the system Remote keypads provide the user with the facility to set and unset the system from strategic locations within the premises and allow the installer to program the system Up to TWO remote keypads may be connected to a system The keypads also have an optional key press PA facility The 9454 is a five zone system with three open collector type outputs The 9455 is a six zone system with three single pole relay outputs In both systems one output is timed Sounders one is untimed strobe and one is fully programmable If required the 9455 can incorporate a keyswitch for full setting and unsetting Technical Specification Zones 9454 Five plus entry exit and PA all closed circuit With individual tamper 9455 Six plus entry exit and PA all FSL Display LED Keypad
6. Up Before applying power to the control panel or end station ensure that all used circuits are connected The control panel or end station lid switch should be defeated or closed and NO power connections to detectors sounders or battery should be made at this stage 496331 Issue 1 5 of 12 Programming Commands 9454 5 Note If connections to the bell and AUX power are made when the system is powered up damage to the main pcb may occur Apply mains to the control panel or end station The green Power and Day LED will illuminate and the internal sounder will sound Key in the factory default customer code 1234 The internal sounder will stop and the Tamper Service and Fault LEDs will be flashing Key in the factory default engineer code 0 followed by ENTER then 7890 The Fault and Service LEDs will flash and the internal sounder will be bleeping Open the control panel or end station lid The internal sounder stops bleeping and the Service LED will be steady Make connections to AUX power stand by battery and connections to SAB Proceed to program the system Note If an SAB SCB module is fitted within the bell it will continue to ring until the panel supply is connected and until the bell cover lid tamper switch is closed Programming Commands To change the factory default program use the commands listed in this section as follows 1 2 3
7. considered an abnormal condition as shown on the opposite page 10 of 12 496331 Issue 1 9454 5 Fault Finding Oentrviexit PO O Zone 1 pay O Zone 2 FULL O O Zone 3 PART _ Zone 4 panic al SERVICE TAMPER power pay ENTRY EXIT Zone 1 O Zone 2 FULL O O Zone 3 PART _ O Zone 4 panic z SERVICE TamPeR ans power oO pay ENTRY EXIT O Zone 1 O Zone 2 FULL O O Zone 3 PART _ O Zone 4 i O Be SERVICE TAMPER FAULT Telephone line fault Alarm activated on Zone 1 System requires Engineer reset Tamper fault Battery not charged or missing remote keypad missing back tamper normal circuit tamper or bell tamper faults If there is no SAB fitted link OV to TR ENTRY EXIT power ENTRY EXIT power ENTRYIEXIT power d O Zone 1 pay O Zone 1 pay Zone 1 pay O Zone 2 FULL O O Zone 2 FULL O O Zone 2 FULL C Zone 3 PART _ Zone 3 PART C Zone 3 PART _ O Zone 4 Zone 4 O Zone 4 panic z O PANIC z O panic Z O Preen SERVICE Cee SERVICE et SERVICE FAULT C FAULT FAULT C Tamper fault has occurred Panic alarm has occured Mains failure Enter user code twice to clear Reset the panic button Check the fault LED is extinguished then enter the user code twice to clear the system ENTRY EXIT power Zone 1 pay Zone 2 FULL O Zone 3 PART C O Zone 4 Panic
8. for Entry Exit BATT tones connect to one 9040 VOL 21VAC 16 ohm loudspeaker a 2 z ai 1 O oooooooojoooooo0o0jooooo000j0o0000000 12345678 910 11213141516 17 18 1920222324 252 27 2829 30 332 EXIT ENTRY ZONE 1 ZONE 6 PA ET OV SIG 11V ov 12 Volt AUX NCAlarm tamper 400mA Contacts contacts Connect to maximum RKP 3 9425 available terminals AKT lt resistor f f f mli 2k2 End of line or Keyswitch resistor Figure 2 9455 PCB Layout 496331 Issue 1 3 of 12 Communicator Output Pins 9454 5 AT SPEAKER 9455 Control Panel l l l LS STROBE l NC l oP 1 l c STROBE no A l c x Typical High Power l rT TT External Sounder SCB l NO aa S E a l l BELL I i C nx I t 1 Tamper Switch i ov t 2 w i I l i Input Trigger l I TR H Tamper Switch l I ve EEn e E E Lt a l na Trigger shown as ve Removed l ve l ee eae M Figure 3 Wiring a Bell to the 9455 Notes 1 Bell O P programmed as normally closed SCB 2 Link TR toOV if no external tamper is required 3 Connect all bell wiring to the control panel with the exception of the 12V Aux supply until initial power up is complete then final connections can be made 4 You can fit a maximum of two 9040 16Ohm speakers to the 9455 if the internal speaker is d
9. isconnected 5 The SCB module shown is a typical example only See manufacturers instructions supplied with individual units for further information on wiring diagrams Communicator Output Pins Pin on panel Function Colour Pin on communicator Pin 1 PA Red ST2 Pin2 Line Monitor Input Blue O P Pin 3 Intruder Yellow ST3 Pin 4 Open Close Black ST4 Pin 5 12V Brown 12V Pin 6 OV Orange OV 4 of 12 496331 Issue 1 9454 5 Keypad Wiring Notes 1 Pins 3 and 4 are 5V positive removed in alarm to trigger 2 Pin 2 is a 12V ve input for Line Fault 3 If a communicator is fitted and has an output for line fault connecting a ve to the Line Monitor Input will reduce any programmed bell delay to zero and give a visual indication on the panel LED LF 4 If acommunicator is not fitted remove the communicator wiring harness from the main pcb Keypad Wiring 9425 PCB PIEZO BUZZER TAMPER SWITCH VOL uPsigovev VOLUME CONTROL FOR 2009 a CUT LINK FOR KEYPAD TONES ONLY REMOTE KEYPAD ADDRESS NO 2 To next FROM CONTROL e keypad if PANEL using daisy chain IP SIG ov V T EXITTERMINATE PUSHBUTTON Figure 4 Keypad Connection Notes 1 Maximum cable distance Daisy chain 300m Star Wire 100m per leg 2 Do not wire the extension speaker or circuit wiring within the same cable as the remote keypad Programming Initial Start
10. s 1 built in plus up to two remote keypads 9425 Expansion None BS 4737 Full Spec Log 9454 15 events 9455 15 events Panel Siren Yes Extension Spkr 9040 1 max Battery 6 5 Ah 12 V Power 9454 Quiescent Panel 50mA 9455 quiescent panel 65mA 9425 RKP 40mA 12V Aux Output 500mA Dimensions Panel h x w x d 163 x 257 x 72mm RKP hxwxd115x 115 x 28mm Weight Panel 1 7Kg approx Comms Output 2 of 12 9454 PA Intruder Open Close 9455 PA Intruder Open Close 496331 Issue 1 9454 5 Wiring NVM ENTRY EXIT VOL RESET PINS l l COMS O P POSITION OF KEYBOARD SUB BOARD OVER MAIN PCB I BATT l l 21Vac PCB FIXING SCREW LI CONTROL PANEL COVER O FIXING SCREW peieoue Shear 0 0000000 o000 c00Jooodfooo o900foo0dfoo00000000 a am 2 a m 4 NB EE EEAT PAJ ET OV fav s B tv OV TR LS OPI ov m aT PAAT se E N 4 CCT1 AT1 AT2 ccT2 N ET OV SIG 12V ro As CCT1 NC Alarm Contacts n NO Exit ie o Menpar Terminate NO Alarm Contacts Pusi to Make L Buton Connect to RKP e g Pressure Pad 9425 Terminals Figure 1 9454 PCB Layout NO Exit Terminate Push to Make Button Kick START n m RST l l l I POSITION OF KEYBOARD SUB BOARD OVER MAIN PCB COMMS j L Volume control
11. s the pins power up the control panel battery first then Mains All the LEDs will flash 4 Remove the screwdriver blade The control panel loads the factory default codes 5 Key in 1234 then press 0 Enter 7890 Momentarily close then open up control panel lid Re program the system Engineer Reset When an engineer requires to reset the system e g after an alarm condition the control panel or end station lid does not require to be opened Enter the engineer code to reset the system followed by 99 496331 Issue 1 9 of 12 Fault Finding 9454 5 To Re Enter Programming Mode 1 Press 0 then Enter 2 Key inthe Engineer Access Code The Fault and Service LEDs flash and the internal sounder starts bleeping 3 Open the control panel lid The internal sounder stops bleeping and the Service LED glows stead ily The system is now in programming mode To Leave Programming Mode 1 Close the panel lid 2 Keying9g Fault Finding Under normal conditions the Fault Service and Alarm LEDs will not be illuminated Only the Mains Day Full and Part Set LEDs should be illuminated during normal use of the system Any other LEDs which are illuminated or flashing signify a fault or alarm condition Note The Mains LED will be illuminated permanently Any condition indicated by a combination of the Fault Service or Alarm LEDs are to be