OPERATING INSTRUCTIONS FOR Clegg Impact Soil Tester 20 Kgs
Contents
1. button on the side of the Digital Readout Unit See Picture 11 below Picture 11 CIST 883 Readout Unit On Off Button Battery Level Indication Battery life is dependant upon the battery type frequency of system use the interval between use and ambient temperature Maximum battery current is drawn when the CIST 883 Readout unit is Bluetooth connected to the PC Assuming this is a rare event an 18 month battery life can be expected based upon the use of two AA alkaline type batteries When the CIST 883 Readout Unit is first switched on the battery status of the two AA batteries is shown on an AA battery level gauge display on the LCD display for 3 seconds See Pictures Picture 12 and Picture 13 below Picture 12 AA Battery Level Good Picture 13 AA Battery Level Lower But Still Acceptable for System Operation The vertical bar shown in the battery level gauge display moves from the right to left as the two AA batteries gradually become more discharged Page 10 of 23 Note When the battery capacity is nearly exhausted the CIST 883 Readout Unit will display BATTERY after each drop test This indicates both batteries should be replaced using fresh batteries both of the same type When the batteries are totally exhausted the CIST 883 Readout Unit will display BAT FAIL after a drop test The unit will then switch off Both batteries should be changed immediately
2. OPERATING INSTRUCTIONS 2 Instructions to be read before use Hy Ram Mansfield Pelham Street Mansfield Nottinghamshire NG18 2EY Tel 01623 422982 Fax 01623 661022 FOR Clegg Impact Soil Tester 20 Kgs 1 Machine to be operated by trained personnel Hy Ram Bury 9 Portland Industrial Estate Portland Street Bury Lancashire BLO 6EY Tel 0161 7641721 Fax 0161 7620577 Hy Ram Enfield Unit 2 Riverwalk Business Park Riverwalk Road Enfield EN3 7QN Tel 0208 805 8010 Fax 0208 805 6010 Page 1 of 23 Hy Ram Livingston 18 Napier Square Houstoun Road Trading Estate Livingston West Lothian EH54 5DG TEL 01506 440233 Fax 01506 440266 Hy Ram Engineering Co Ltd has a policy of continuous improvement in product quality and design Hy Ram Engineering Co Ltd therefore reserves the right to change the specification of its models at any time without prior notice Important This manual forms a part of the product to which it relates It should be kept for the life of the product Any amendments issued by Hy Ram Engineering Co Ltd should be incorporated in the text The manual should be passed to any subsequent holder or user of this product HEALTH amp SAFETY UNLOADING PRECAUTIONS The 20 Kg Clegg Impact Soil Tester is supplied packed in a crate designed to locate the 20Kg Hammer within the Guide Tube During transit the foam inserts in the crate help prevent the Hammer moving within the Guide Tube Exer
3. After the battery level display shown in Picture 12 and Picture 13 above the LCD display will show 000 IV 0 as in Picture 14 below Picture 14 CIST 883 LCD Display Initial Display Automatic Switch Off and Manual Switch Off A timer circuit in the Digital Readout Unit switches the unit OFF automatically approximately 5 minutes after the last signal input hammer drop The Digital Readout Unit can also be switched off manually at any time To do this press and hold the ON button for about 3 seconds until the display shows OFF Release the button and the Digital Readout Unit will switch off THE DIGITAL READOUT UNIT DISPLAY Reading from left to right on the Display of the Digital Readout Unit the first 3 digits are the Impact Value IV the next 2 characters are the symbol IV the final digit is the number of times the Hammer has been dropped cycling through 1 to 5 after which the drop number is repeated A reading of 25 IV and drop number 5 is shown Picture 15 below Picture 15 LCD Showing 25 IV and Drop Number 5 The Display covers a range of Impact Value IV from 003 to 101 IV in increments of 1 IV If an Impact Value IV of greater than 101 is obtained the display will indicate STOP NOW Further tests at this site location should be discontinued However in practice the range of IV likely to be encountered would typically be from about 5 IV soft ground to 80 IV hard ground Display Zeroing The Digital R
4. prematurely stopped Ensure therefore that testing at each location is carried out by dropping the hammer at intervals less than 17 seconds e The Digital Readout Unit will switch off automatically 5 2 minutes after the last hammer drop e On completion of tests at any location raise the Hammer whilst it is in the Guide Tube for access to the locking pin block on the T Hammer handle Re insert the locking pin Gently lower the Hammer locating the locking pin in the slots or side holes in the Guide Tube Checking the Clegg Impact Soil Tester Performance using the Operational Check Ring Rudimentary system checks can be made by using the Operational Check Ring hereinafter referred to as the Ring The Impact Value IV is shown together with the serial number of the instrument on the rim of the Ring supplied with the system The marked value is typical and the actual value obtained during a test varies depending upon the surface type Page 13 of 23 the Ring is placed upon and the manner in which the hammer lands onto the Ring A typical Ring IV value at the manufacturer s is about 22 IV when the hammer lands evenly on the Ring As the Ring material is not truly representative of an actual soil surface occasionally erroneous readings of around 10 IV may be displayed when the hammer base falls unevenly onto the Ring The calibration certificate shows 20 x evenly loaded hammer drop IV s only To carry out the test using the Ring proceed as
5. 17 below This sets the nominal drop height to 310 mm 12 2 If preferred steady the CIST by holding the top of the Guide Tube handle If necessary get assistance for this operation Make sure that the Hammer is positioned centrally in the Guide Tube minimising the contact between the Hammer and the inside wall of the Guide Tube Picture 17 Keep Top of Hammer Level with Top of Guide Tube Within 10mm e Release the Hammer from the set height of drop allowing it free fall Note the Impact Value IV displayed on the Digital Readout Unit and check the drop number which should show 1 The Hammer should be allowed to fall cleanly else the reading may be affected e Next without moving the Guide Tube repeat the raising and dropping of the Hammer four more times noting the Impact Values at each drop The Impact Value observed at the fourth drop should be recorded as the relevant IV provided that the fifth value is not significantly different from the fourth drop value When the 5th drop has taken place if the readout has been configured by the user to display Clegg Hammer Modulus CHM the readout will display the 5th drop Impact Value IV and then it will display the CHM of the 5th drop e The CIST 883 Readout Unit automatically resets the display to zero and the drop number to zero when the interval between successive hammer drops exceeds 17 seconds This is to ensure that inadvertent readings are not shown when testing is
6. NiMH is the preferred option over the obsolete Nickel Cadmium type NiCad NiMH types have a higher capacity than NiCad batteries and they suffer less from memory effect However NiMH batteries have a higher selfdischarge rate and will be exhausted in a few months if not re charged Lithium Lithium batteries are more powerful but they are usually more expensive to purchase compared to Alkaline types They are not rechargeable They are toxic and should be disposed of properly at the end of their life in a hazardous waste facility BATTERY LIFE AND BATTERY LEVEL INDICATION Battery life is dependant upon the battery type frequency of system use the interval between use and ambient temperature Maximum battery current is drawn when the CIST 883 Readout unit is Bluetooth connected to the PC Assuming this is a rare event an 18 month battery life can be expected when using two AA alkaline type batteries based upon intermittent usage Battery level indication is displayed for the first 3 seconds after the unit is switched on Page 17 of 23 DO NOT LEAVE THE BATTERIES IN THE CIST 883 READOUT UNIT FOR LONG PERIODS If the CIST 883 Readout Unit is to be left for several months without use the batteries should be removed from the Readout otherwise corrosion from the batteries may cause damage to the internal electronics Care of Equipment Do not allow sharp edged objects to fall onto or press into the display window of the CIST 883 Re
7. follows e Select a test location which should be a clean horizontal level and hard base such as concrete Brush the surface clear of loose material and debris e Switch the Digital Indicator Unit ON and check that the display reads 00 IV O ePlace the Clegg Impact Soil Tester CIST vertically in position ensuring that the Guide Tube sits squarely on the surface under test To check this place both feet on the foot plate at the base of the Guide Tube to ensure that the vertical position of the Guide Tube is maintained If the Guide Tube rocks in this position move the CIST to a location nearby e Lift the Hammer slightly and remove the Hammer locking pin stowing it in the mounting hole in the support bracket Place both feet on the foot plate at the base of the Guide Tube to maintain stability of the CIST Now lift the Hammer completely out of the Guide Tube and stand it nearby ensuring that the Connector Cable is not stressed e Place the Ring centrally inside the Guide Tube on the surface at the base of the Guide Tube Lift the Hammer back and steady it on the rim of Guide Tube Place both feet on the foot plate at the base of the Guide Tube to maintain stability of the CIST Carefully lower the Hammer into the guide tube until the top of the Hammer mass is level with the top of the Guide Tube e Extreme care is needed at these next stages of the test procedure to ensure complete safety of the operation e Maintain the Hammer susp
8. Microsoft Windows PC running the Data Handler software provided in this consignment Page 2 of 23 The CIST 883 20 Kg Clegg Impact Soil Tester shown in Picture 1 below consists of the following individual component parts The Connecting Cable The Operational Check Ring The Adjustable Mounting Block with Side Clamps for the CIST 883 Readout Unit Hole at side is to locate the Hammer Support Pin The 20 Kg Hammer amp T Lifting Handle The 20 Kg Hammer with T Lifting Handle The Guide Tube with Notches for the Hammer Support Pin The Adjustable Mounting Block with Side Clamps for the CIST 883 Readout Unit The CIST 883 Digital Readout Unit SDi Software amp USB Bluetooth Adapter The CIST 883 Digital Readout Unit Operates from 2 x AA alkaline or similar batteries The Connecting Cable The Guide Tube with Notches for Hammer Support Pin Later models have holes in the Guide Tube for this purpose instead The Operational Check Ring Picture 1 SDi 20 Kg CIST 883 Clegg Impact Soil Tester The 20 Kg Hammer with T Lifting Handle The Hammer consists of a 130mm diameter cylindrical mass with a precision accelerometer rated to many times the normal instruments working range mounted on its top under the T lifting handle The assembly weighs approximately 20 Kg When testing the hammer mass is raised so the top part of the red mass is level with the top of the Guide Tube This sets the
9. READOUT DISPLAY REMAINS READING ZERO i If the Readout display shows 000 IV 0 and does not change when Hammer is dropped on Operational Check Ring replace the cable ii If the Readout display remains at 000 IV 0 return complete instrument for repair CIST 883 READOUT GIVES LOW READINGS i Check that the hammer and the meter unit have the same serial number to ensure that a matched combination is being used ii Clean inside of guide tube and the barrel and end face of the hammer Check instrument out with Operational Check Ring iii If Readout display still gives low readings check out instrument with Operational Check Ring iv If Readout display still gives low readings return complete instrument for repair CIST 883 READOUT GIVES HIGH READINGS i Check that the hammer and the meter unit have the same serial number to ensure that a matched combination is being used ii Check that the hammer is not impacting on a stone or other hard object Move to a new position if necessary iii If Readout display still gives high readings check instrument out with Operational Check Ring iv If Readout display still gives high readings return instrument for repair CIST 883 READOUT SUDDENLY SHOWS A ZERO READING WHILST TESTING i This is not a fault and ensures that erroneous readings are not held displayed by the readout unit if the user stops testing Ensure that the time interval between successive hammer drops is ke
10. READOUT UNIT BEFORE STARTING A SERIES OF TESTS Yes by using the Data Handling PC software The user clicks the delete stored data tab and then clicks the delete data button Trouble Shooting Guide A list is given below of possible fault conditions that may be encountered during use of the instrument with suggestions for clearing faults CIST 883 READOUT DISPLAY REMAINS BLANK i If meter display does not show characters when ON OFF button is pressed replace both AA batteries ii If display still remains blank return the complete instrument for repair CIST 883 READOUT DISPLAY SHOWS STOP NOW WHEN SWITCHED ON BEFORE TESTING STARTS i Disconnect cable from readout and press button If display shows 000 IV 0 then cable is faulty Repair or replace cable ii If display still shows STOP NOW return the complete instrument for repair CIST 883 READOUT DISPLAY SHOWS STOP NOW DURING TESTING ii The surface under test is too hard Move to an alternative test area CIST 883 READOUT DISPLAY SHOWS BATTERY i Indicates a low battery condition Replace both AA batteries at earliest convenience The instrument can still be used however Page 19 of 23 CIST 883 READOUT DISPLAY SHOWS BAT FAIL ii Indicates end of battery life Replace both AA batteries immediately CIST 883 READOUT DISPLAY SHOWS ABORT i TREND operation is activated and the IV values exceed limits CIST 883
11. adout Unit as the clear window may crack or puncture A damaged display window may affect the sealing integrity of the CIST 883 Readout Unit Care must be taken regarding the coaxial cable and the BNC connectors Avoid kinks or overstressing the cable Ensure that the BNC connectors on the cable Hammer and CIST 883 Readout Unit are kept clean and dry In standing the instrument upright take the following precautions e Ensure the Hammer Locating Pin is in place if left unattended e Ensure it does not topple on uneven or rough ground e Ensure it does not get knocked over accidentally e Ensure the wheels on the Guide Tube are not banged down hard on the ground during unloading or manoeuvring This can damage the wheels and or the axle studs Exercise common sense when it is raining regarding use Do not let the CIST 883 Readout Unit become excessively wet and always dry the unit after use Ensure the connectors and cable connections are kept dry after use Do not repeatedly drop the hammer onto uneven hard ground or stones This can cause weakness in the weld at the base of the T handle caused by rapid side ways acceleration jerks of the hammer mass as it comes to rest Clean and dry the instrument as necessary especially before storage Clean and dry the instrument as necessary especially before storage Clean any remnants of soil build up from the base of the cylindrical hammer prior to use and before storage To protect against
12. any possible battery leakage remove the two AA batteries from the CIST 883 Readout Unit if the Tester is to be left in storage 15 Frequently Asked Questions AT THE END OF A TEST IS THE OPERATOR PROMPTED TO SAVE OR DISCARD THE RESULT AND THEN MOVE ON TO THE NEXT TEST The result is automatically saved if the operator completes a 5 drop test If he wants to abandon the saving he just stops dropping the hammer for more than 17 seconds After 17 seconds the reading on the unit clears to zero and the previous drops in the test are automatically deleted from memory Example the user completes 3 drops in quick succession or within 17 seconds of each hammer drop His mobile phone rings just as he is about to start the 4th drop He puts down the Tester and answers his phone The conversation lasts longer than 17 seconds and he finishes his call He then goes back to the Tester and the display will have reset to Page 18 of 23 zero This means he has to start his run of 5 drops again This auto zeroing is present to help reduce the number of partial test results that may otherwise occur in the stored data So the user does not have to press any extra buttons to save the data It is automatically saved if he completes 5 drops because the set of 5 drops is a complete data set If he wants to abandon a data set then he stops dropping the hammer and in 17 seconds the display zeroes Alternatively he can briefly press the On button at the side
13. arge for return of the products back to the customer e This warranty statement gives the customer specific legal rights The customer may also have other rights which vary from country to country in the world Page 21 of 23 Pre conditions for Warranty Application Hy Ram Engineering Co Ltd warranty covers only those defects which arise as a result of normal use of the product and this warranty shall only apply in the following circumstances a All the instructions contained in the operating manual have been complied with b And none of the following apply i Improper or inadequate maintenance ii Physical abuse iii Unauthorised modification misuse or any use not in accordance with the operating manual and good industry practice iv Operation outside the products specifications v Improper site preparation or maintenance and vi Faulty pipe or fittings Limitations of Warranty a Hy Ram Engineering Co Ltd does not warrant the operation of any product to be uninterrupted or error free b Hy Ram Engineering Co Ltd makes no other warranty of any kind whether express or implied with respect to its products Hy Ram Engineering Co Ltd specifically disclaims the implied warranties of satisfactory quality and fitness for a particular purpose c To the extent that this warranty statement is inconsistent with the law of the locality where the customer uses the product this warranty statement shall be deem
14. cise extreme caution when unloading the Tester from the crate as it may be possible for the Hammer to become dislodged from its rest position during the unloading manoeuvre INTRODUCTORY HANDLING PRECAUTIONS The 20 Kg Clegg Impact Soil Tester requires careful handling at all times during preparation and use to ensure safe working and freedom from accidents A few commonsense precautions should always be observed Use extreme care when lifting and handling the Tester To avoid straining the back do not attempt to lift the assembled tester without assistance Keep the feet clear of the Hammer when it is being loaded into the guide tube and when it is released during testing and operation of the equipment INTRODUCTION This manual describes the 20 Kg Clegg Impact Soil Tester type CIST 883 The CIST 883 is used to test the surface conditions of earthwork materials and established paved surfaces Testing involves dropping the 20 Kg Test Hammer five times at each test location When the Hammer is strikes the surface under test the accelerometer in the Hammer generates an electrical pulse The magnitude of the pulse depends upon the surface characteristics The instrument records the accelerometer pulse and displays readings in terms of Impact Values IV with a maximum reading scale of 101 IV Clegg Hammer Modulus display is also available The test data can be stored in the CIST 883 Readout unit and this can be downloaded wirelessly using Bluetooth to a
15. drop height Maintain this drop height between tests to within 10mm in order to maintain consistency of readings A coaxial socket in the end of the handle T cross piece provides a connection for the accelerometer output signal 3 1 2 The Guide Tube with Notches Holes for the Hammer Support Pin The Guide Tube made from aluminium directs the fall of the 20 Kg Hammer during operation It also provides a parking place for the Hammer when the Tester is being moved around on site In this mode the Hammer is supported clear of the ground in the Guide Tube by means of the Locating Pin which passes through the locating ferrule on the Hammer handle and is supported by the holes in the Guide Tube The Guide Tube assembly is mounted on wheels which remain clear of the ground while the Guide Tube is vertical and which engage with the ground when the tube is tilted at an angle and is being pulled along with its handle When a test is to be carried out the Locating Pin is removed and placed in the spare hole in the Adjustable Mounting Block Later models have solid through holes in the Guide Tube for the Locating Pin Picture 2 Locating Pin Supporting the 20 Kg Hammer During Local Site Transportation Page 4 of 23 Adjustable Mounting Block With Side Clamps for the CIST 883 Readout Unit The adjustable mount on the Guide Tube handle provides a support for the CIST 883 Readout Unit The Mount can be set at a convenient height for optimum
16. e from obstructions Loosen the screw fixing the Mounting Block and position it at a suitable viewing height clear of the tube Tighten the screw See Picture 7 below Picture 7 Tighten the Screw to Secure the Mounting Block Page 8 of 23 Clip the Digital Readout Unit on to the Mounting Block Plug the connecting cable to the coaxial connector on underside of the Digital Readout Unit Ensure that the connector plug locks into place on the socket See Picture 8 and Picture 9 below Picture 8 Clip Digital Readout to Adjustable Mounting Block Picture 9 CIST 883 Readout BNC Connector Connect the other end of the Connector Cable into the socket on the T piece of the Hammer handle See Picture 10 below Picture 10 Connector cable in T Handle The complete assembly can now be pulled along Note Earlier models use two support grooves for the Hammer Support Pin at the top of the Guide Tube This arrangement does not secure the Hammer in the Guide Tube and care should therefore be exercised when moving the Tester around to ensure that the Hammer does not become detached from the Guide Tube THE CIST 883 DIGITAL READOUT UNIT DESCRIPTION SWITCHING ON THE CIST 883 READOUT UNIT amp OBSERVING BATTERY LEVEL Page 9 of 23 The CIST 883 Readout Unit is supplied with two AA sized batteries Check these have been installed in the instrument Switch On Press the ON Button Press and then release the ON
17. eadout Unit display can be reset to zero at any time during a test run This is achieved by briefly pressing the ON button Automatic Zeroing Display The CIST 883 Readout Unit automatically resets the display to zero and the drop number to zero when the interval between successive hammer drops exceeds 17 seconds This is to ensure that inadvertent readings are not shown when testing is prematurely stopped Page 11 of 23 Ensure therefore that testing at each location is carried out by dropping the hammer at intervals less than 17 seconds Clegg Hammer Modulus Display When the CIST 883 Readout Unit has been configured to display the Clegg Hammer Modulus CHM the CHM is displayed 3 seconds after the 5th Hammer drop reading Example For a fifth drop Impact Value IV5 of 25 IV the Clegg Hammer Modulus is calculated as 144 MPa and displayed on the LCD as shown in Picture 16 below Picture 16 Example CHM Calculated as 144 MPa for a 5th Drop IV of 25 IV Note The CHM will only be displayed providing the following two situations are met 1 The TREND limits during the 5 drops in a test shown in table Table 1 2 The CHM option has been enabled in the CIST 883 Readout Unit See description of how to enable disable the CHM facility Test Procedure Using the Clegg Impact Soil Tester The 20 Kg Clegg Impact Soil Tester is intended for use on flexible pavements or on equivalent materials or on deeper than standard lifts for earthwork
18. ed modified by the minimum necessary to be consistent with such local law d To the extent allowed by local law the remedies provided in this warranty statement are the customer s sole and exclusive remedies e This tool has been designed for the range of fittings available at the time of its design and development Hy Ram Engineering Co Ltd can accept NO liability for the unit s ability or otherwise to work with new or different fittings that subsequently appear in the market place Page 22 of 23 Please complete this information and keep it safely with your proof of purchase receipt You will require it for any warranty claim Where purchased sede Date of purchase sdvssie pa a a a aaa aiaa aaa Name amp caddress teeter a eee eee AU EUEN Ei Of purchaser Typeoft ol OyO A ere nee es ce aed 8 ates hol ees iat tl Dears SeflalWeimber eee cetoeden at d aa Sr arai aaa ETI AETAT TETELE ITER iu apria For Service and repair please contact Hy Ram Mansfield Pelham Street Mansfield Nottinghamshire NG18 2EY Tel 01623 422982 Fax 01623 661022 Page 23 of 23
19. ended at the level attained in the previous stage and transfer one hand from the Hammer to the grip on the handle of the Guide Tube to steady it If necessary get another person to steady the Guide Tube e Release the Hammer to let it free fall on to the Ring Because of the high elasticity of the Ring material the Hammer will bounce in the Guide Tube before settling on the Ring Note the IV reading on the display of the Digital Readout Unit e Repeat the test two or three times to ensure consistency of results Before repeating the test each time lift the Hammer clear of the Guide Tube observing the previously listed safety precautions and check that the Ring remains resting on the surface at the base of the Guide Tube Ensure that at each drop the Hammer falls cleanly without contacting the inner wall of the guide tube e Ignore unusually low readings caused by an uneven landing of the hammer onto the Ring e If the Impact Values obtained during the above tests differ more than 4 digits the calibration of the CIST may have changed and the measurement accuracies could be impaired Under these circumstances it may be necessary to return the Clegg Impact Soil Tester to Hyram for inspection possible repair and re calibration Page 14 of 23 e On completion of the tests raise the Hammer sufficiently whilst it is in the Guide Tube to gain access to the locking pin bracket on the Hammer handle Re insert the locking pin Gently lower the Hamm
20. er turning it to locate the locking pin in the slots or side holes in the Guide Tube HOW TO FIT BATTERIES IN THE CIST 883 DIGITAL READOUT UNIT CIST 883 READOUT UNIT BATTERY FITTING The CIST 883 Readout Unit operates from 2 x 1 5V AA size batteries that are located in an IP67 rated battery compartment located at the base of the CIST 883 Readout Unit It is unlikely that the batteries will require replacement between routine re calibration intervals as the typical battery life is in excess of 12 months However if battery access is required it is necessary to remove the circular battery cap located under the yellow protection plate at the base of the CIST 883 Readout Unit shown in Picture 36 below The procedures are explained below Picture 36 CIST 883 Battery Cap Protected by Yellow Plate To fit new batteries carry out the following procedures in order a Start and finish the procedures below in a dry and clean environment b Unclip the CIST 883 Readout Unit from its Readout Bracket and remove the connecting cable c The battery cap is protected by a rectangular yellow cover plate shown in Picture 36 above The plate is held secured using four Button Head screws Remove the yellow cover plate by unscrewing all four Button Head screws using the 2mm Allen Key provided Note the positions of the various washer combinations used in the assembly prior to unscrewing each Button Head screw as they will be required when re securi
21. fety Requirements e If this tool has reached the end of its useful working life and cannot be refurbished it must be disposed of through a licensed scrap or waste disposal facility Alternatively a reverse engineering company could be used to strip the equipment for recycling purposes e Disposal is the responsibility of the Customer this can also be achieved by returning the product back to the manufacturer Warranty Information 1 Extent of Warranty a Hy Ram Engineering Co Ltd warrants to the end user customer that its products will be free from defects in materials and workmanship for six months after the date of purchase by the end user customer subject to providing proof of purchase b If Hy Ram Engineering Co Ltd receives during the warranty period notice of a defect in product which is covered by this warranty Hy Ram Engineering Co Ltd shall either repair or replace the product at its option Any replacement product may be either new or like new provided that it has functionality at least equal to that of the product being replaced c All warranty work will be carried out by Hy Ram Engineering Co Ltd unless otherwise agreed On site warranty and repair or replacement services are available from authorised Hy Ram Engineering Co Ltd service facilities world wide d Customers shall prepay shipping charges for products returned to Hy Ram Engineering Co Ltd for warranty service and Hy Ram Engineering Co Ltd will ch
22. m damaging the terminal prongs inside the battery cap The yellow cover also stops inadvertent tampering of the battery cap i Ensure that when the batteries are replaced the full complement of screws and washers comprising the yellow plate assembly are re used in the correct order See Picture 39 below If items are lost spares can be obtained from Hyram Page 16 of 23 Picture 39 Battery Cover M3 Stainless Button Head Screw amp Washer Assembly j Re secure the CIST 883 Readout Unit to the Readout Bracket using the pair of clamps AA BATTERY TYPES Use two AA size batteries in the CIST 883 Readout Unit Each AA battery should be of the same type and should produce an off load voltage of nominally 1 5 Volts A comparison of battery type is provided here Alkaline If rechargeable batteries are not available or required alkaline batteries are economical Battery types such as the Duracell Ultra Energizer Advanced Formula or Kodak Photolife provide good service although unbranded types are also suitable There is not much difference in battery capacity from brand to brand They all perform similarly despite the battery manufacturers claims The spread between the best and worst alkaline types is in the region 10 15 Generally regular unbranded alkaline types provide sufficiently good service and are widely available Nickel Metal Hydride NiMH If rechargeable batteries are required Nickel Metal Hydride
23. ng the plate See Picture 37 below Page 15 of 23 Battery Cap Picture 37 Protection Cover Removed Exposing Battery Cap d When the yellow cover plate has been removed carefully unscrew the circular battery cap shown in Picture 37 above by turning it anti clockwise about 40 degrees A spring inside the battery compartment will push out the first battery and may try to flick the battery cap away due to the spring action Be careful not to lose the battery cap when it is pushed by the spring e Angle the CIST 883 Readout Unit down so that the second battery is ejected f Insert two new batteries of the same type ensuring that both their positive connections face outwards No damage will result if they are inserted the wrong way round but the unit will not operate See Picture 38 below Picture 38 When Battery Cap Removed Batteries Can Be Replaced g Take care when re securing the battery cap and ensure the two flange prongs on the battery cap locate into the corresponding slots in the Readout opening Ensure the battery cap is rotated clockwise sufficiently to provide its IP67 rated seal A mechanical end stop provides tactile feedback when the cap is sufficiently tightened but DO NOT over tighten h The battery cap provides waterproofing properties but it must be protected by the yellow cover when the equipment is in service or during shipment The yellow cover prevents inevitable shock loads experienced during handling fro
24. of the readout and this also clears the display and removes the previous drops in a 5 drop test Also note that the Readout Unit can be set to not store data by configuring it using the Data Handling Software This means it will not store any data at all until enabled again by the software WOULD THE OPERATOR WITHOUT A PC KNOW IF THERE ARE RESULTS IN MEMORY BEFORE USING THE UNIT AND WITHOUT LINKING IT TO A PC No the user would not know if there are results in memory already This should not be a problem though because firstly there is sufficient flash memory capacity in the Readout Unit to hold up to 9999 tests 49 995 hammer drops and it is extremely unlikely the memory will be used up Secondly the user will be able to identify his set of data when downloaded into the PC because each set of data has the time and date Example User 1 carries out 50 tests 250 drops on Monday and he then downloads his data to the PC However he forgets to clear the stored data in the readout On Tuesday user 2 carries out 100 tests 500 drops When user 2 downloads the data to the PC there will be 150 tests downloaded these being the first 50 tests from user 1 and the 100 tests from user 2 User 2 will be able to identify his results knowing that he carried out his tests on a different day and time He can than delete the first 50 tests easily within Excel or whatever the program is that he uses to view the data CAN THE OPERATOR CLEAR THE MEMORY FROM THE
25. pt below 17 seconds at each test location otherwise the test reading and displayed drop number will reset to zero THE BATTERY COVER CAP DOES NOT FIT PROPERLY i The circular battery cap whilst providing good waterproofing properties is a delicate component It must be protected using the yellow rectangular cover plate when the equipment is being used for testing and also when the equipment is being transported If the Clegg Impact Soil Tester has been handled roughly and the protection plate has not been secured properly the metal flange contacts in the battery cap may bend and the battery cover may no longer provide a good seal or may become detached completely Page 20 of 23 RETURNING INSTRUMENTS FOR CALIBRATION OR REPAIR The Clegg Impact Soil tester is a precision measuring instrument and should be calibrated every 12 months Hyram carries out a repair and re calibration service and can arrange collection and delivery back if needed Certificate of calibration e This product has been inspected and tested in accordance with the ISO9001 quality control systems and procedures in place at Hyram Engineering Co Ltd e This product has been calibrated using equipment traceable to national and international standards Decommissioning amp Disposal Instructions These give the instructions for decommissioning and disposal of the equipment and confirm how it is to be taken out of service safely in respect of the Essential Health and Sa
26. s roadworks or airfield runways and aprons It is not advisable for use directly on concrete or on materials of similar hardness The suggested test procedure is as follows e Ensure the Hammer strike face is clean and free from material build up and that the hammer mass and the inside of the Guide Tube are clean so as not to impede the free fall of the Hammer e Select a test location and brush the surface clear of loose material and debris scuffing with the foot is usually adequate e Place the Clegg Impact Soil Tester CIST vertically in position ensuring that the Guide Tube sits squarely on the surface under test To check this place both feet on the foot plate at the base of the Guide Tube to ensure that the vertical position of the Guide Tube is maintained If the Guide Tube rocks in this position move the CIST to a location nearby e Lift the Hammer slightly and whilst holding it remove the Hammer Support Pin Stow it in the hole located in the Adjustable Mounting Block to keep it clear of operations Carefully lower the Hammer back in the Guide Tube letting it settle on the surface under test Keep both feet on the foot plate at the base of the Guide Tube to maintain stability of the CIST e Press and then release the ON button on the Digital Readout Unit The Display should read 000 IV O Page 12 of 23 e Raise the Hammer until the top surface of the mass is level to within 10mm of the top of the Guide Tube See Picture
27. their mating connectors pressing in and turning to the right through 90 degrees until the connectors lock in place Ensure the cable and the end connectors are kept clean and dry Wipe off residual moisture at the end of every testing session The Operational Check Ring The Operational Check Ring is used to check the basic functioning of the CIST 883 Tester Test the system every month by dropping the Hammer onto the ring through the Guide Tube The Operational Check Ring is an annular ring of high density plastic material To obtain a reading from the Operational Check Ring place it on a hard surface centrally in the Guide Tube Drop the Hammer on to it in the same way a normal test is carried out The Operational Check Ring IV will be displayed on the CIST 883 Readout Unit The readings from the Operational Check Ring vary and depend upon the hardness of the ground onto which the Operational Check Ring is placed temperature and humidity A reading of approximately 18 to 24 is achieved at Hyram premises The Operational Check Ring is not to be used a means to calibrate the system Only use it for quick operational checks Failure to achieve a reading near the range indicated may mean the equipment is faulty Page 6 of 23 THE 20 Kg CLEGG IMPACT SOIL TESTER PACKING CRATE The packing erate for the 20 Kg Tester is designed for its transportation and storage Padded fittings inside the case help prevent component movement duning transporta
28. tion Before unpacking the Tester fram the case carefully noting the warning given in paragraph 1 1 on page above Observe the best practices for the manual handling of heavy loads If preferred get assistance for this procedure iba a Rove Bee EE te a AE THC LISLE GF THe Caley BE Le W M bad Te sa iai ii Tea b oO ae T mi THE ALE aiy Gui Ai Per Bar MLA UAE Re PALETOU oe ama TIR TEE FLEE MEAN RP LAAS pe pA ee 2 PO Cee a ga BEC ED eee BA AT AL T ee a Oe es HT Picture 5 20 Kg Transit Storage Case amp Schematic Page 7 of 23 AFTER UNPACKING PREPARING THE 20 Kg CLEGG IMPACT SOIL TESTER FOR TESTS Check that the underside of the 20 Kg Tester Base Plate is clean Stand the Guide Tube Assembly upright on a clean and level surface Ensure the Hammer Support Pin is centrally located within the circular hole in the bracket on the T Hammer handle The Hammer Support Pin should be settled in the grooves in the top edge of the Guide Tube The grooves in the Guide Tube are offset to allow the Hammer to hang centrally The Hammer is lifted by the Hammer Support Pin such that the Hammer base is clear of the ground See Picture 6 below Picture 6 20 Kg Hammer Supported by Hammer Support Pin in the Guide Tube Slots Note In later designs two holes located on adjacent sides of the Guide Tube are used to support the Hammer Support Pin Ensure that the internal bore of the Guide Tube Assembly is clean and fre
29. viewing conditions and is fitted with a rotary screw key to lock it in position The clasps either side of the mount locate on the clips of The CIST 883 Readout Unit The clasps should be positioned to lock against the readout clips and the clasps must be locked down when using the Tester The CIST 883 Readout Unit should be unclamped from the mounting block during transportation The two stainless steel clamps align with the strikes on the CIST 883 Readout Unit To lock the Readout to the bracket the clamps are aligned to the strikes on the CIST 883 Readout Unit and pushed back until they click into their stable locked position Ensure they are both securely locked into position prior to the commencement of testing Picture 3 Stainless Steel Clamping for the CIST 883 Readout Page 5 of 23 The CIST 883 Readout Unit The CIST 883 Readout Unit is the measuring electronics and means of display of the measured results This is a separately housed self contained instrument When the Tester is being prepared for carrying out measurements the CIST 883 Readout Unit is placed in position on the Mounting Block paragraph 3 1 3 above and connected to the Hammer via the Connector Cable The Connecting Cable The connecting cable is connected between the socket in the T Lifting Handle and the CIST 883 Readout Unit Both ends of the cables are inserted into their respective sockets by lining up the slots of the cable connectors over the pins of
Download Pdf Manuals
Related Search
Related Contents
OPERATION AND SAFETY MANUAL - Hy 製品カタログデータ (PDF形式、2596kバイト) AirChek52 - Eco Environmental AKAI STB-2680 English user manual 取扱説明書 - オークセール Power Supply Modules - ps-2.kev009.com, an archive of old advertencia Archimedes World June 1991 Nearly Free Gefen 4x4 User's Manual a&s Italy n.24 Dicembre 2013 Copyright © All rights reserved.