INSTALLATION/OPERATING INSTRUCTIONS FOR 7 DAY
Contents
1. INSTALLATION OPERATING INSTRUCTIONS FOR 7 DAY ELECTRONIC PLUG IN TIMER MODEL NUMBER T17B C T74A C Please read these instructions fully before attempting installation OPERATING INSTRUCTIONS e Insert the timer into a wall outlet to allow the internal battery to charge It is recommended that this be for at least 30 minutes Depress the reset button to ensure that memory is clear The built in battery allows for programming while the unit is not plugged in and provides for memory retention during power failures Once the unit has been charged the battery back up will last at least 150 hours CURRENT TIME AND DAY SETTING Press the R button to reset the timer to its default settings activate using a pencil or similar pointed instrument pressing R will delete all stored programmes Press Y to enter function setup Note If another button is not pressed within 10 seconds the display will revert to the normal screen Use the or button to scroll to the clock icon flashing and press Y to enter the current time setting mode hours flashing If you keep the or buttons pressed for more than 3 seconds the display will enter fast scroll mode Use the or button to adjust the hours and press Y to confirm minutes will flash Use the or button to adjust the minutes and press Y to confirm day will flash Use the or button to adjust the day and press N to exit PROGRAM MING THE SWI
2. TCHING TIMES 1 There are 24 ON OFF programmes available 2 Press the Y button twice to enter the programme setting mode Note If another button is not pressed within 10 seconds the display will revert to the normal screen m N GREENBR K Default is programme 01 ON this can be changed if required by pressing the or button to scroll through the 24 ON OFF programmes as required pressing the Y will confirm the programme Press the Y button to confirm programme 01 ON hours will flash 5 Use the or button to adjust the hours and press Y to confirm minutes will flash Use the or button to adjust the minutes and press Y to confirm days will flash Apart from individual days of the week the following day combinations of multiple day blocks can be selected by pressing the or buttons f e Monday to Sunday e Monday to Friday e Saturday amp Sunday e Monday to Saturday e Monday Wednesday Friday e Tuesday Thursday Saturday e Monday Tuesday Wednesday e Thursday Friday Saturday 8 Select day or day block as required and press the Y button to confirm 9 Press the button this will select the programme 01 OFF press Y to confirm 10 Follow 4 to 7 above to set the 01 OFF programme day or day block must be the same as programme ON 11 If no more programmes are required press the N button to exit 12 If more programmes are required follow 3 above 13 To ca
3. anently ON e Q PROG timer is in programme N mode will switch off at the next programme OFF time OFF e PROG timer isin programme OFF mode will switch on at the next programme ON time SUMMERTIME SETTING 1 Press the Y button then use the or buttons to scroll through to summer flashing 2 Press the Y button again to access the summer time setting 3 Press the or button to change between summer on or off 4 Press Y to confirm summer setting time will advance by 1 hour 5 A SUMMER icon will appear in the display 6 Use the same procedure to remove the SUMMER icon when reverting to GMT in the winter RANDOM SETTING The random setting allows the timer to switch ON and OFF with a random delay of between 2 and 32 minutes This function will only operate if one or more switching programmes have been programmed into the timer 1 Press the Y button then use the or buttonsto scroll through to RANDOM flashing 2 Pressthe Y button again to access the random setting 3 Pressing the or buttons will toggle the random icon on and off 4 Pressthe Y button to confirm random function ALWAYS OFF timer is permanently M emory location 5 A RANDOM function icon will appear in the display 6 Timer will now operate in the random mode 7 To cancel random feature use the procedure above to remove the RANDOM icon from the display RESET Pressing the reset button R w
4. ith a pencil or similar will reset all programmed times and set time of day to zero READING YOUR PROGRAMMED TIMES 1 Press the Y button twice to enter programme mode 2 Press the or buttonsto scroll through the 24 ON OFF programmes to check settings 3 Press the N button to exit and revert to clock mode TECHNICAL DATA Switching capacity 230 Vac 3000W 13A resistive 2A inductive Ambient temperature 10 C to 55 C Running reserve 150 HOURS 24 Shortest switching time 1 minute Programmable Every minute Your GreenBrook 7 Day Electronic Plug in Timer is guaranteed for 12 months PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE REFERENCE GreenBrook Electrical Plc West Road Harlow Essex CM 20 2BG Email gbe greenbrook co uk Web page www greenbrook co uk cE Issue number 701117
5. ncel a programme once set press and hold the N button for more than 3 seconds when the desired programme number is flashing i e to cancel programme 01 ON press the Y button twice and hold the N button down for more than 3 seconds to delete Pressing the button again will select the 01 OFF 14 Repeat 13 to delete 01 OFF This procedure can be repeated to delete any of the 24 programmes TIMER COUNTDOWN FUNCTION 1 Timer has a 100 hour countdown feature i e The timer can be set to any period from 1 minute to 100 hours and will countdown in the ON state and turn OFF at the end of the countdown period 2 Pressthe Y button then use the or button to select the down icon on the right hand side of the display press Y again to enter the countdown mode 3 Use the or button to adjust the hours and press Y to confirm minutes will flash 4 Use the or button to adjust the minutes and press Y to confirm and complete the countdown time setting 5 Press the N button to start the countdown 6 Output switched to ON during the countdown period 7 Press the N button to pause the countdown output switched to OFF 8 To resume countdown simply press the N button again 9 Press and hold the N button for more than 3 seconds to exit the countdown function MANUAL OVERRIDE 1 When in normal clock mode pressing the N button will scroll through the following switching options ALWAYS ON timer is perm