Home
Operating Instructions
Contents
1. Press to provide a Help Menu for the current display p and also to provide status More More Press 3 to navigate down Fire Events Events through menu selections Press 2 to navigate right through menu selections Press exit to return to the Main Menu Press Enter to enable the menu selection Control functions for More Fire Events and More Events are provided on the following page FIRE are DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 Operating Controls Operate controls to navigate the menu and to perform functions for Exit Enter More Fire Events and More Events Name Description and Operation More Provides event status for Fire fires Displays the number of a a Events alarms present and overrides the display provided by menu navigation To operate this function 1 Press the More Fire Events button 2 Read event on the LCD mean Events 3 Press 3 to scroll through the list of additional events More Provides event status for Events non fire alarm events Displays the number of events and overrides menu selection To operate this function 1 Press the More Fire Events button 2 Read event on the LCD 3 Press 3 to scroll through the list of additional events Navigation controls and function controls for Exit and Enter are provided on the previous page FIRE ere DETECTION SYSTEMS Part Number VF3535 00 Revisio
2. be in Access Level 2 to operate commands Reference the previous page to open the menu to Access Level 2 Re Sound Alarm Panel Sounder Lamp Alarm Silence Silence Test Controls Re Sound Alarm Alarm Silence Panel Sounder Silence FIRE are DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 Programmable Enable Access Function D Reset Fire Drill Description Re sounds the alarm following a muting event initiated by the panel sounder silence or alarm silence command Mutes the internal buzzer as well as the sounders connected to the control panel Initiating this command mutes sounder devices on the entire network Mutes the internal buzzer of the control panel No other sounder outputs are silenced by this command Reset clears latching inputs on the control panel Latching inputs remain active after correcting the cause of the input event Perform a reset to clear latching inputs on the control panel caused by supervisory trouble pre alarm and fire signals Non latching inputs do not require the reset Non latching inputs clear after correcting the cause of the input condition 8 Operating Controls Operate controls to navigate the menu and to perform functions for Exit Enter More Fire Events and More Events Description and Operation A Press 1 to navigate up a le through menu selections Press 4 to navigate left Vv through menu selections
3. control unit board Connections at this location are faulty or disabled FIRE ame DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 Interpreting Panel Information Monitor the internal sounder LED indicators NAC sounders and LCD messaging to interpret panel information Normal Standby The normal standby condition is displayed on the LCD when the control panel is operating without troubles or alarms TIME DAY DATE DEFAULT OR USER DEFINED MESSAGE USE ARROW KEYS TO ENABLE PANEL PRESS FOR HELP Trouble Silence The example below illustrates a trouble condition caused by an open circuit connection to a NAC device on a control panel LEDs flash yellow during a Fire oera NAC Trouble condition General Ac Power On 2 Disablement LCD message Pre Alarm General Trouble ELECO Power Trouble ALM 000 TBL 0001 SUP 000 Panel Sounder P Silenced Orren 00S 000 REL 00 Delay Active Han TROUBLE NAC CIRCUIT 2 ZONE 0 NODE 1 AUTOLEARN s Monit d Output Troubl gt Internal buzzer sounds Care nes Te The following conditions occur after pressing Panel Sounder Silence to silence a NAC Trouble event The Panel Sounder Silence LED lights continuously The internal sounder of the control panel does not annunciate The LCD displays a trouble condition message The General Trouble LED stops flashing yellow FIRE ies DETECTION SYSTEMS Part Numb
4. FIRE ee DETECTION SYSTEMS e Operating Instructions These instructions apply to all models of the eLAN RS and Elite RS Panel Initiate the following to interpret panel information review controls open Access Level 2 operate controls and identify an emergency contact Operation Interpreting Panel Information Opening Access Level 2 Reviewing Commands Operating Controls Emergency Contact p FIRE oes DETECTION SYSTEMS e Part Number VF3535 00 Revision E01 02 Date 1 20 2012 Description Page Monitor LCD messaging 2 6 LED illumination and sounder activation for status Open Access Level 2 to obtain status and to operate controls Review commands for re sound alarm alarm silence panel sounder silence and reset Operate controls to navigate the menu and perform commands for Exit Enter More Fire Events and More Events Contact the individual or company responsible for providing assistance in the event of an emergency Interpreting Panel Information Monitor the internal sounder LED indicators Notification Appliance Circuits NAC sounders and LCD messaging to interpret panel information Fire AC Power On Pre Alarm 0n Test Panel Sounder Silenced Delay Active AC Green Power On Pre Alarm Yellow FIRE ite DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 More Events General C Disablement C Power
5. Trouble Supervisory NAC Trouble Descriptions for On Test Panel Sounder Silenced Delay Active and More Events are provided on the following page General Trouble Descriptions for General Disablement General Trouble and Power Trouble are provided on page 4 Descriptions for Supervisory and NAC are provided on page 5 Description A fire alarm or fire drill condition exists The status condition is provided on the LCD display The control panel buzzer sounds intermittently Output relays are activated Flashing NACs activated On Continuous NACs silenced OFF Panel and NACs reset AC power is on A pre alarm condition exists Pre alarm status is provided on the LCD display The buzzer on the control panel sounds continuously Interpreting Panel Information Monitor the internal sounder LED indicators NAC sounders and LCD messaging to interpret panel information G Descriptions for Fire Fire More Events AC Power On and AC Power On general Pre Alarm are provided on Disablement the previous page Pre Alarm General Trouble Descriptions for General on Test Power Trouble Disablement General Panel Sounder 2 Silenced Delay Active NAC Trouble LED Color On Test Yellow Panel Yellow Sounder Silenced Delay Active More Yellow Events FIRE te DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 Tr
6. er VF3535 00 Revision E01 02 Date 1 20 2012 Opening Access Level 2 Open Access Level 2 to display status messaging and to operate commands and controls Operate the keypad or the enable access key switch to open Access Level 2 Using the keypad Press the 3 button on the upper control pad The following message is displayed on the LCD SET ACCESS LEVEL 2 MENU Enter Access Level 2 Password Use numbered arrow keys kkkkk Access will automatically expire after 120 seconds if no key is pressed ENTER TO PROCEED EXIT TO QUIT Type the five digit code in the password field using the upper control pad and then press Enter Using the enable access key switch Turn the enable access key switch to the right as shown in the figure below Turn key to the right The following message is displayed on the LCD 15 29 Monday 19 May 2009 AUTO CONFIGURED PANEL ACCESS LEVEL 2 VX XXXXX USE ARROW KEYS TO VIEW MAIN MENU Menu commands are now accessible using Access Level 2 Go to Operating Controls of this guide to operate the control panel Press buttons on the lower left control pad to perform commands for panel sounder silence alarm silence re sound alarm or reset Reference Reviewing Commands on the previous page for an overview of these commands FIRE a DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 Reviewing Commands The control panel must
7. n E01 02 Date 1 20 2012 Emergency Contact Contact the company or individual responsible for providing assistance in the event of an emergency In the event of an emergency notify Name Company Primary Telephone Secondary Telephone Cell Phone Address City State FIRE Sa DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 FIRE ae DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012
8. ory and NAC are provided on the following page Description Options of the LCD menu have been used to disable specific devices A General Trouble condition exists when flashing The General Trouble condition is also identified by other lit LEDs Status is provided on the LCD display The buzzer sounds continuously A status condition caused by many factors not limited to the input power line power supply or AC line fuse During the Power Trouble condition Power Trouble LED flashes Internal buzzer sounds LCD displays the trouble cause Other LEDs can be illuminated 4 Interpreting Panel Information Monitor the internal sounder LED indicators NAC sounders and LCD messaging to interpret panel information Descriptions for Fire AC Fire More Events Power On and Pre Alarm are provided on page 2 2 i inti Descriptions for On Test Pre Alarm General Trouble Panel Sounder Silenced Delay Active and More On Test Power Trouble Events are provided on page 3 AC Power On Panel Sounder Silenced Supervisory Descriptions for General Delay Active NAC Trouble Disablement General Trouble and Power Trouble are provided on the previous page Key LED Color Description K Supervisory Yellow A supervisory point has been activated Status is provided on the LCD display The buzzer sounds continuously NAC Trouble Yellow A NAC trouble exists on one of the NAC circuits of the
9. ouble and Power Trouble Supervisory are provided on the following page Descriptions for Supervisory and NAC are provided on page 5 Description A test is in progress The panel sounder silence button was depressed NAC outputs are not effected NAC sounders have been delayed from sounding during a fire condition The Delay Active LED is flashing and the internal buzzer is sounding Press Alarm Silence to mute and extend the Delay Active condition NAC sounders will annunciate after this Delay Active period if Alarm Silence is not pressed More events have occurred than are displayed on the LCD Press the More Events button to display the complete event list Interpreting Panel Information Monitor the internal sounder LED indicators NAC sounders and LCD messaging to interpret panel information Fire More Events General Ac Power On Disablement C Pre Alarm General Trouble On Test Power Trouble Panel Sounder Silenced Supervisory Delay Active NAC Trouble LED Color General Yellow Disablement General Yellow Trouble Power Yellow Trouble FIRE ote DETECTION SYSTEMS Part Number VF3535 00 Revision E01 02 Date 1 20 2012 Descriptions for Fire AC Power On and Pre Alarm are provided on page 2 Descriptions for On Test Panel Sounder Silenced Delay Active and More Events are provided on the previous page Descriptions for Supervis
Download Pdf Manuals
Related Search
Related Contents
SafeGuard LAN Crypt 3.61 E.book Emerson SW46 Owner's Manual Registre santé sécurité au travail : mode d`emploi Uso e manutenzione Sika®CarboDur® - Distribuciones Villamar 80 ーg。 Braun 320 取扱説明書等(1) - アイ・オー・データ機器 FlexPak 3000 OIM 4.2 - Rockwell Automation Trousse combinatoire HISTO SPOT On-Call Typing Copyright © All rights reserved.