Home
Installation and Operating Instructions
Contents
1. The texts on this screen may appear in a foreign language Click on Terminal Einstellungen Display settings Select the abbreviation of your language Press gt The language in the Service application will be changed a a E 5 E Click on Sprache Language E E E El 8 Restart terminal gt The language in other applications will be changed 1 4 Adjusting the brightness for day or night mode In this chapter you will learn how to adjust the brightness of the display for day or night mode Procedure 1 Open the Service application Service Copyright M ller Elektronik GmbH amp Co KG 31 Configuring the terminal in the Service application M LLER lektronik Configuring the basic display settings gt tla re Following screen will appear 3 Display settings File management Driver settings MW Plugin settings 7 Licence management ME BASIC Terminal TOP V 03 70 00 2 Change the operating mode Depending on which operating mode is currently active you can use one of the function icons Activate day mode Activate night mode gt The brightness of the display will be adjusted immediately 7 5 Configuring the basic display settings The basic display settings can be adjusted on the Display settings screen Procedure 1 Switch to the Display settings screen Service Display settings gt
2. gt The following screen will appear 5 Diagnostics t FarmPilot t LightBar t Camera 2 Click on LightBar gt The installed drivers will appear 3 Click on the LightBar_ME driver gt Next to the driver the icon o will appear 4 Restart terminal gt You have activated the external LightBar If you activated the Section Control or TRACK Leader II applications you must also activate the external LightBar in these applications For instructions on how to do so please refer to the operating instructions of these applications 7 15 Camera 7 15 1 Activating a camera If you have connected a camera or camera system to the terminal you must activate it To activate a camera or a camera system you must first activate its driver Procedure 1 Switch to the Driver settings screen Service Driver settings 2 The following screen will appear 5 Diagnostics t FarmPilot LightBar Camera 3 Click on Camera 4 Click on the Camera ME driver Copyright M ller Elektronik GmbH 8 Co KG 45 Configuring the terminal in the Service application M MULLE lektronik Camera gt Nextto the driver the icon G will appear 9 Restart terminal gt The following function icon will appear on the start screen of the Service application 6 You have activated the camera driver 7 15 2 Operating the camera Controls Switch
3. Procedure You can configure the parameter as follows M The DGPS Receiver A100 from Muller Elektronik is connected and activated M The driver of the external LightBar LightBar_ME is deactivated Otherwise the DGPS Receiver cannot be configured M The external LightBar is not connected 1 Switch to the GPS screen ea AS 4 Service Copyright M ller Elektronik GmbH amp Co KG 39 Configuring the terminal in the Service application Configuring the GPS TILT Module terrain compensation MULLER lektronik 7 11 Procedure 40 gt The following screen will appear a e e gt Satellite 1 Satellite 2 i Steering gt Z Correction signal ME GPS V02 01 02 2 E Click on the desired parameter gt A selection list will appear 3 Click on the desired value gt Next to the value the icon G will appear 4 Back gt Forsome parameters is it necessary to restart the terminal In these cases the following notification will appear Settings will be adopted after restart gt You have configured the DGPS Receiver Configuring the GPS TILT Module terrain compensation M The GPS TILT Module terrain compensation is connected M The driver of the external LightBar is deactivated M The external LightBar is not connected 1 Measure the distance between the GPS Receiver and the ground surface 2 Switch on the terminal 3
4. Once you have started the Service application the kei screen will appear PRHKKIKKIHKKHAKKANKIAKKANKKHAKKAKKAKKKAKKIKKKAKKAKKKKKKAKKKAKKAAAKAAKKANEIKKKANKKAKKAKKAAKKKAKKIKKAAAKAAKASKKIANKANKAAALAAASANEASKSAAAAAASAASAASSAASSASSAAASAAS passeeeesessesssssssesaeeasesseesseeses z x Display settings File management Driver settings 2 Plugin settings 7 Licence management BASIC Terminal TOP V 03 68 00 Pannnunsnsuuunnunnunnuunnunnennnnnnnnne Start screen of the Service application 1 Main section 3 Cursor Screen contents Selects a line that can be clicked on with the rotary knob 2 Version number Function icons section Name of the terminal and version of the Icons that can be pressed on this screen installed software Controls in the Service application The Service application is controlled using the rotary knob and the function keys Some of the function icons explained here will only appear if a specific function is activated This limits the information shown on the display to just the information that you need for your work Scroll There is one more page with function icons Back Activate day mode Activate night mode File cannot be deleted grey Selected object cannot be deleted Copyright M ller Elektronik GmbH amp Co KG 29 Configuring the terminal in the Service application Icons in the Service application MULLER lektronik Fu
5. 4 3 3 Connecting the terminal to the basic eguipment Procedure 1 Insert the 9 pin cable of the basic equipment into the 9 pin socket A on the terminal 2 Tighten the safety screws on the connector 4 4 SIM card The terminal must be eguipped with a SIM card so that you can use the FarmPilot portal If you do not intend to use the FarmPilot portal you will not need any SIM card Which SIM card You must purchase the SIM card from your mobile phone provider Select a mobile phone provider that can guarantee good mobile phone reception on your fields A good connection is reguired in order for your work with the FarmPilot portal to run smoothly The SIM card must meet the following reguirements It must be GPRS capable The contract must enable data transfer It must be PIN free Inform your mobile phone provider about this requirement before purchasing the SIM card 4 4 1 Inserting the SIM card Required tool Torx TX10 screwdriver Procedure 1 Switch off the terminal and disconnect all cable connections to other equipment 2 Unscrew the SIM card cover on the reverse of the terminal Use a Torx TX10 screwdriver 16 Copyright Muller Elektronik GmbH amp Co KG m Mounting and installation MULL lektronik SIM card 3 Press latch release with finger nail 4 Raise the card holder The card holder can be raised on the right hand side where the casing is rounded The card holder is held in place by hinges on the other sid
6. GPS Receiver offset for ISO machines 20 Copyright M ller Elektronik GmbH amp Co KG m Mounting and installation M LLER lektronik GPS Receiver Attachment point for attachment and trailer GPS Receiver equipment 1 Attachment and trailer eguipment 2 Self propelled machines y Distance for offset Y X Distance for offset X Procedure Thus you can calculate the distances for machines with attachment and trailer eguipment with an ISOBUS jobcomputer M The jobcomputer of the farm eguipment in use is connected to the terminal M In the jobcomputer the geometry of the farm equipment is configured 1 Measure the distance between the attachment point of the attachment and trailer eguipment and the GPS Receiver 2 Enter the distance measured as parameter Offset X 3 Measure the distance between the longitudinal axis of the machine and the GPS Receiver 4 Enter the distance measured as parameter Offset Y Procedure Thus you can calculate the distances for self propelled machines with an ISOBUS jobcomputer M The jobcomputer of the farm equipment in use is connected to the terminal M In the jobcomputer the geometry of the farm equipment is configured 1 Enter 0 cm as parameter Offset X 2 Measure the distance between the longitudinal axis of the machine and the GPS Receiver 3 Enter the distance measured as parameter Offset Y For machines not fitted with a jobcomputer Non ISO machines are not fitted with a jobc
7. 22 Copyright Muller Elektronik GmbH amp Co KG m Basic control principles MULLE lektronik Using the function keys Switch the terminal on and off gt Has no function daD Has no function ED Exit screen Cancel input Hide warning messages and alerts Open the Selection menu application Exit the Selection menu application 5 2 Using the function keys Whenever you use the function keys you will activate the function depicted on the adjacent function icon When you press a function key the function operation depicted on the function icon will be performed Using the function keys Function icon Function key Depiction of an available function Performs the function depicted on the function icon Example Pressing the function key 2 activates the function depicted on the function icon P If no function icon is displayed next to a function key the associated function key is currently without function Copyright M ller Elektronik GmbH 8 Co KG 23 Basic control principles M LLER lektronik Initial start up 5 3 Initial start up Procedure 1 Installing and connecting the terminal 2 Switch on the terminal 3 Wait for approx 15 seconds until all applications have been loaded 4 Open the Selection menu application gt The following screen will appear Service n E 3 u 8x26 8xA88810880C488AAF c E Hi i i r j 7 ol 8x87 8xA88C88888C
8. Creating a Task data folder on the USB flash drive You must create a Task data folder in the following instances f you use the TaskManager without the FarmPilot portal f you wish to export the machine settings to the Farm Management Information System Procedure 1 Insert an empty USB flash drive into the terminal 2 Openthe TaskManager application TaskManager gt The following screen will appear A We Fields 29 Farms jes Customers s Farm equipment ME TM V 02 00 60 TE v 00 13 01 G gt Ifthe following function icon appears on this screen the folder has already been created ZZ GR na EE 4 4 0 Press 3 Press Tii gt The Task data folder is being created on the USB flash drive gt A function icon will appear on the Master data screen AX ST 8 6 2 Transferring data via the FarmPilot portal You will receive data from the portal if they are sent by a dispatcher The dispatcher will always send the data as sets of tasks that consist of one or more tasks Procedure You will receive the set of tasks from the dispatcher as follows M You have opened the TaskManager application M You have inserted a USB flash drive into the terminal VI NOTE The USB flash drive must not contain a folder named TASK DATA However if the folder does exist you must save gt 83 the existing data on the USB flash drive 1 The dispatch
9. 488884 TaskManager HH OXF 8x488882888C488A8F TRACK Leader HH 8x1C 8xA88817808C488A8F gt You are now in the selection menu gt Now the connected jobcomputers will be loaded The progress of this process is indicated by the progress bar next to the jobcomputer icon The time taken to complete this process depends on the number of connected jobcomputers 5 Wait until all jobcomputers have been loaded gt The following screen will appear Service 8x26 8xA88810888C488A8F s57 h2de 8x87 8xA88C88888C 488884 TaskManager OXF 8xA880820808C 488 A8F TRACK Leader 8x1C 8x488817888C488A8F All jobcomputers are loaded when no more progress bars are displayed 6 In the selection menu you can select which application you wish to display next E 7 Select the Service line The Service line must be framed by a black square mm Service FH i mi 6x26 0x088081D888C488319 JA 8 O Click on the Service line 24 Copyright M ller Elektronik GmbH 8 Co KG m Basic control principles M LLER lektronik Restarting the terminal gt The following screen will appear 2 File management Driver settings MW Plugin settings 7 Licence management ME BASIC Terminal TOP V 03 70 00 gt You have opened the Service application 9 Configuring the terminal in the Service application gt 29
10. 5 4 Restarting the terminal When restarting the terminal you must give the connected jobcomputers enough time to restart as well For this reason always wait approx 30 seconds after switching off the terminal before switching the terminal back on Procedure 1 Switch off the terminal 2 Wait 30 seconds until the jobcomputers have also been switched off 3 Switch on the terminal Copyright M ller Elektronik GmbH amp Co KG 25 Opening applications in the selection menu Display layout in the selection menu M LLER lektronik 6 Opening applications in the selection menu In the selection menu you can choose which application you wish to view on the display You can open the selection menu at any time This will not close the application currently running Controls G E Open the selection menu Press again open the most recently activated application Display the application in the header of the split display Display the application in the main section of the display 6 1 26 Display layout in the selection menu The display is split into the following sections Function icons left and right Applications section in the middle between the function icons LLL VAIN gt BQ Ptieidnvav TRACK Leader 8x1C 8x488017888C daa AAF Sections in the selection menu 1 Name of an application 2 Function icons on the left Select an applicati
11. Switch to the configuration screen of the terrain compensation Service Terrain compensation Copyright Muller Elektronik GmbH amp Co KG ki Configuring the terminal in the Service application M LLER lektronik Screenshots gt The following screen will appear GPS Receiver height 8 500 ft Null point calibration Angle 1 4 Enter the distance between the GPS Receiver and the ground surface in the line GPS Receiver height 5 Position the tractor on a ground surface that is known to be level 6 Click on the line Null point calibration gt The position of the terrain compensation on an even surface is being calibrated gt After calibration the angle 0 will appear in the line angle The angle displayed changes every time the tractor tilts 7 12 Screenshots A screenshot is a photo of the display If an error occurs when you are using the terminal Customer Services may ask you to capture a screenshot A screenshot can be emailed to Customer Services Email address service mueller elektronik de sent to the FarmPilot portal provided you have activated the FarmPilot portal 7 12 1 Configuring the screenshots function Procedure M You have activated the Diagnostics function gt 42 1 Start the Service application Service 2 LE Open the Diagnostics screen 3 Click on Screenshot settings 4 Click on Activate screenshots gt The st
12. Target group of these Operating Instructions These Operating Instructions are intended for personnel entrusted with installing and operating the terminal 2 2 Layout of operating instructions The operating instructions explain step by step how you can perform certain operations with the product We use the following symbols throughout these Operating Instructions to identify different operating instructions Type of depiction Actions that must be performed in succession a Result of the action This will happen when you perform an action gt Result of an operating instruction This will happen when you have completed all steps Reguirements In the event that any reguirements have been specified these must be met before an action can be performed 2 3 Layout of references If any references are given in these Operating Instructions they will appear thus Example of a reference gt 9 References can be identified by their sguare brackets and an arrow The number following the arrow shows you on what page the chapter starts where you can find further information Copyright M ller Elektronik GmbH 8 Co KG 9 Product description Performance description M LLER lektronik 3 Product description 3 1 Performance description Components The terminal is eguipped with the following components Interface for controlling the ISOBUS jobcomputer GSM modem only in conjunction with the terminal
13. The following screen will appear R Volume 20 F2 Date time EE Language en 5 5 Measure Metric Keyboard brightness 50 E E 2 Change the desired parameter Day Adjust the brightness for day mode Night Adjust the brightness for night mode Night mode Switch night mode on and off 32 Copyright M ller Elektronik GmbH 8 Co KG ki Configuring the terminal in the Service application MULLER a Mi E lektronik Activating and deactivating applications 0 day mode is activated 1 night mode is activated Time zone 0 Time zone Greenwich Mean Time GMT 1 GMT 1 hour Germany 1 GMT 1 hour Select measure system metric imperial US American user defined Keyboard brightness Set level of keyboard brightness in percent 7 6 Activating and deactivating applications In the Service application you can activate and deactivate other applications that are installed on the terminal The applications are installed in packages in so called plugins A plugin can contain several applications Name of the plugin Includes the following applications TaskManager TaskManager TRACK Leader TRACK Leader SECTION Control TRACK Leader TOP FIELD Nav FIELD Nav Procedure 1 Switch to the Plugin settings screen Service Plugin settings Copyright Muller Elektronik GmbH amp Co KG 33 Configuring the terminal in the Service application Activating licenc
14. appear re 5 Disabled GPS PSRCAN M GPS 4100 t Diagnostics FarmPilot t LightBar amp Camera gt Next to the active driver the icon G will appear gt The driver GPS A100 for the DGPS Receiver A100 from Muller Elektronik comes activated as standard 4 Select the line containing the correct antenna driver GPS_A100 if the DGPS Receiver was connected directly to the terminal port C GPS_PSRCAN if the GPS Receiver was connected via the CAN interface i e to a jobcomputer 5 Click on the selected line gt Nextto the driver the icon G will appear 6 Restart terminal gt GPS Receiver is activated gt The following function icon will be displayed on the start screen of the Service application GPS gt You have activated the GPS Receiver 7 10 2 Configuring the DGPS Receiver A100 The DGPS Receiver A100 is delivered ready configured However you can change the configuration In this chapter you will learn how to do this Parameters You can configure the following parameters in the process Baud rate Setting for the speed at which the terminal sends data to the DGPS Receiver The parameter sets the baud rate for the terminal The default baud rate is 19200 This baud rate is suitable for the DGPS Receiver A100 Satellite 1 and Satellite 2 Only required with the correction signal WAAS EGNOS Satellite 1 primary DGPS satellite The DGPS Receiver will conne
15. automation The two signals CAN L and CAN L or CAN Hand CAN H are linked internally and used to loop the CAN bus through Assigning CAN EN in to the supply potential Vin enables the terminal to be switched on When switched on the terminal supplies voltage to the CAN_EN_out minus approx 1 2 V which is required to activate the connected jobcomputers The signals Vin and CAN GND are directly linked with both connectors therefore it is crucial to avoid differences in potential between the pins of these two connectors 9 4 3 Pin assignment of port C Port C is an RS232 interface Damage to the equipment caused by short circuit Pin 4 of port C is live The voltage depends on the operating voltage of the terminal and is used to supply the DGPS Receiver A100 from Muller Elektronik Other GPS Receivers may suffer damage if connected to this port Before connecting a different GPS Receiver Check what voltage the terminal is connected to 12 V or 24 V Check the pin assignment of the GPS Receiver Check the allowable voltage for the GPS Receiver Compare the terminal voltage to the allowable voltage for the GPS Receiver Compare the pin assignment Only connect the GPS Receiver to the terminal if the voltage range and pin assignment of both devices don t differ from each other Copyright Muller Elektronik GmbH amp Co KG 87 Maintenance and servicing Technical specifications M LLER lektronik
16. between several cameras Rotate image Switch fullscreen on and off Save camera settings You can press the function keys even if the camera is set to fullscreen mode Procedure M You have connected and activated the camera 1 Switch to the Camera screen O orust M gt The following screen will appear 3 gt pr 2 Use the function keys to control the camera 46 Copyright M ller Elektronik GmbH amp Co KG Configuring the terminal in the Service application MULLE i lektronik Configuring FarmPilot 7 16 Configuring FarmPilot FarmPilot is an internet portal which allows software on a farm computer to exchange data with machines via a mobile phone network Operating data are stored in a central location on the portal and are presented clearly to the user Before you can use FarmPilot in conjunction with your terminal you must complete the following steps Purchase a SIM card and have it activated Activate FarmPilot Enter your FarmPilot access data Refer to the following chapters to learn how to perform these steps 7 16 1 Activating FarmPilot To activate FarmPilot on your terminal you must first activate its driver High costs from prolonged data transfer If you do not have a flatrate in your mobile phone contract continuous use of FarmPilot can lead to high costs If your flatrate has a data volume limit continuous use of FarmPilot can quickly use up your
17. data volume limit o Deactivate the FarmPilot driver when you are not using the portal Procedure 1 Switch to the Driver settings screen Service Driver settings gt The following screen will appear re M ss t Diagnostics t FarmPilot t LightBar Camera 2 Click on FarmPilot 3 Click on the TPD driver gt Nextto the driver the icon G will appear 4 Restart terminal gt The following function icon will appear on the start screen of the Service application ES Copyright M ller Elektronik GmbH 8 Co KG 47 Configuring the terminal in the Service application Configuring FarmPilot M LLER lektronik gt You have activated the FarmPilot portal You must now enter the access data for the FarmPilot portal 7 16 2 Configuring the connection with FarmPilot Before you can connect the terminal to FarmPilot you must configure the connection You will receive this data when purchasing the FarmPilot access data Parameters You will reguire the following parameters for the configuration Username Username for FarmPilot Password Password for FarmPilot Provider Opens a screen where the GPRS connection can be configured With most mobile phone providers this configuration occurs automatically If the access data for the GPRS connection differ with your provider you can configure the connection manually You can find precise instructions in the chapte
18. order that has already been started Use this function in the following instance You have already processed a task and travelled over a portion of the field However you have realised that you wish to process the remainder of the field using a different product or alter the concentration You will not be able to alter the products for a task that you have already started Therefore you will have to split the task Splitting will turn the original task into two tasks Processed portion of the task is marked red and contains all information arising from the processing of this portion Unprocessed portion of the task is displayed on the list as a new task You can continue processing this task The task contains all the field boundaries and field data from the original task Procedure 1 Switch to the Master data screen 66 Copyright Muller Elektronik GmbH amp Co KG TaskManager application MULLER lektronik Step 2 Selecting a task to process gt The following screen will appear af We Fields 28 Farms EM Customers s Farm equipment ME TM V 02 00 60 TC v 00 13 01 2 Click on the Tasks line gt The following screen will appear g Wfertilization 2 00 Field 2 fertilization 2 00 Field 2 t Mueller SS 2 00 Field 2 fem Worker gt The list contains an overview of the tasks stored on the USB flash drive 3 Start the desired task You can only
19. the original task but can be processed like a new task Procedure 1 Switch to the Master data screen gt The following screen will appear We Fields G Farms EM Customers s Farm equipment ME TM V 02 00 60 TC yV 00 13 01 P 2 Click on the Tasks line gt The following screen will appear Hffertilization 2 00 Field 2 fertilization 2 00 Field 2 t Mueller SS 2 00 Field 2 fem Worker 3 Select a task that has the most similarities to the task you wish to create The task must not be Started i 4 4 Create a copy of an existing task gt The following notification will appear Copy task 5 Confirm 64 Copyright M ller Elektronik GmbH amp Co KG TaskManager application MULLER lektronik Step 2 Selecting a task to process gt The following screen will appear 7 fertilization 2 00 Field 2 Bi fertilization 2 00 Field 2 FE fertilization 2 00 Field 2 t Mueller SS 2 00 Field 2 fem Worker gt The new task will be added to the list and marked as a copy with an asterisk gt You have created a new task You now have the following options You can start the task you copied gt 72 8 7 2 Adopting an existing task You can process one of the tasks that appears on the Task list screen The tasks may originate directly from the Farm Management Information System from the FarmPilot portal or from the US
20. the terminal in the Service application Configuring FarmPilot M LLER lektronik E 4 0 Select the desired character a E RK Click on the selected character 6 When you have finished entering all the characters select and click on OK 7 16 4 Configuring the GPRS connection manually In this chapter you will learn how to configure the GPRS connection manually With most SIM cards the GPRS connection will be configured automatically The GPRS connection must be manually configured in the following instances You have bought a new SIM card The terminal does not recognise your mobile phone provider Your mobile phone provider has altered the access data for the GPRS connection Parameters The values you must enter for the parameters depend on your mobile phone provider You can find out these data from your mobile phone provider You will require the following parameters for the configuration Country Country for which the SIM card is configured Cannot be altered Provider Name of the mobile phone provider Appears automatically With unrecognised cards you can enter the name of the mobile phone provider yourself APN Abbreviation of Acces Point Name Address of the GPRS access point DNS 1 and DNS 2 Abbreviation of Domain Name System IP addresses of the first and second DNS servers Number Dialling code for the modem Cannot be altered Username Username for the GPRS connection Passwor
21. to the Licence management screen Service Licence management 34 Copyright M ller Elektronik GmbH amp Co KG Configuring the terminal in the Service application MULLE a lektronik Deleting files from the USB flash drive gt The following screen will appear A O eS veneer TRACK Leader II 50 00 BMJZMZKITLLIJACEFR TRACK Leader TOP 50 00 BMJZMZKJTLLIJACPXY SECTION Control 50 00 BMJZMZKITLLIJACRRU 2 Click on the desired application gt The following screen will appear Name SECTION Control Code BMJZMZKJITLLIJACRRU Key 0000000000 Status deactivated Remaining 3 Enter the activation number in the Key field You will receive the activation number on purchasing a software licence 4 Confirm gt The following icon will appear next to the application on the Licence management screen gt The application is activated You can use the application without any restrictions 7 8 Deleting files from the USB flash drive Potential loss of data Deleted files cannot be retrieved Think very carefully about which file you wish to delete On the File management screen you can delete files from the USB flash drive The File management screen only displays files that are stored in either of the following two folders on the USB flash drive Screencopy contains all screenshots you have created Taskdata contain
22. 00 Field 2 l k Mueller SS 2 00 Field 2 un Worker 4 268 00 I ha AHL 28 66917572ter 3 ME_ISO_SPRAYER a Worker 72 Copyright Muller Elektronik GmbH amp Co KG TaskManager application M LLER lektronik Step 4 Starting a task 3 JON Start the task gt The following screen will appear ek fertilization 2 00 Field 2 if Mueller SS 2 00 Field 2 te ME_ISO_SPRAYER gt The task has a new status Green task started gt The following function icons will appear Stop task x u Navigate to field gt You have started the task You now have the following options You can select machines gt 73 You can select workers gt 75 You can let the application navigate you to the field Only if FIELD Nav has been activated To learn how to do so read the FIELD Nav operating instructions You can process the task in a different application For instance in SECTION Control or TRACK Leader 2 You can stop the task gt 81 8 9 1 Selecting the machine This step requires that you select the machines and farm equipment which will be used to process the task You can add any number of machines and farm equipment The terminal records the length of time worked by the machines you added soits JE Add machine Reactivate deactivated machine press and hold Pin _ Deactivate machine Icons Machines ca
23. AN Trace gt The status of the function is displayed on the icon gt The icon G must appear next to Activate CAN Trace 8 Restart terminal gt After restarting the terminal CAN Trace will log the communication between the terminal and the jobcomputer 9 Leave the terminal switched on until the set CAN Trace duration has elapsed gt The CAN Trace function will be deactivated automatically 10 If you specified USB as the storage location verify that the file Startup Trace txt exists on the USB flash drive E TRACK Leader html 1KB HTML Dokument StartupT race txt 638 KE Textdokument O TaskData_work Dateiordner OD Screencopy D ateiordner O nastore D ateiordner OD fieldfinder Dateiordner 11 If this file is missing you must run the CAN Trace function again 12 Email the Startup Trace txt file to Customer Services If you chose Portal as the storage location this file will have been sent automatically 7 14 Activating an external LightBar If you connected an external LightBar to the terminal you must activate it To activate the external LightBar you must first activate its driver You can order the external LightBar from Muller Elektronik with the following item number 30302490 Procedure 1 Switch to the Driver settings screen Service Driver settings 44 Copyright Muller Elektronik GmbH amp Co KG ki Configuring the terminal in the Service application M LLER lektronik Camera
24. B flash drive The following options are available to you Resume an existing task Splitting a task that has already been started Resuming a task Procedure M You have copied the data from the Farm Management Information System to the USB flash drive M You have inserted the USB flash drive into the terminal 1 Switch to the Master data screen gt The following screen will appear af i We Fields i 29 Farms er Customers s Farm equipment ME TM V 02 00 60 TE v 00 13 01 2 Click on the Tasks line Copyright M ller Elektronik GmbH amp Co KG 65 TaskManager application Step 2 Selecting a task to process M LLER lektronik gt The following screen will appear a lai fertilization 2 00 Field 2 fertilization 2 00 Field 2 t Mueller SS 2 00 Field 2 tiem Worker gt The list contains an overview of the tasks stored on the USB flash drive 3 Click on the desired task It does not matter what icon is used to mark the task You can resume any tasks gt The following screen will appear SKK Lot 7 fertilization 2 00 Field 2 t Mueller SS 2 00 Field 2 ian Worker us 268 00 I ha AHL 28 66917572ter 3 ME_ISO_SPRAYER ey Worker gt The task data have already been filled in for this task You will no longer be able to alter the data You can now read the following chapter Start task gt 72 Splitting an
25. BASIC Terminal TOP GSM item no 30322522 Installed software The terminal comes with the following software installed as standard TaskManager task processing TRACK Leader II 50 hour trial version SECTION Control 50 hour trial version HEADLAND Control 50 hour trial version Optional software Optionally you can activate the following software TRACK Leader II parallel tracking system TRACK Leader TOP automatic steering system SECTION Control automatic boom section switching HEADLAND Control headland management FIELD Nav navigation to the field Please call our sales department if you want to unlock this optional software Differences between the two versions of the terminal There are two versions of the terminal BASIC Terminal TOP item no 30322521 BASIC Terminal TOP GSM item no 30322522 You can identify which terminal you have from the ME item number on the nameplate gt 11 The following table shows the differences in equipment for both versions BASIC Terminal TOP BASIC Terminal TOP GSM je 3 2 Scope of delivery The following items are included in delivery Terminal BASIC Terminal TOP Installation and Operating Instructions Bracket for mounting the terminal USB flash drive 10 Copyright Muller Elektronik GmbH amp Co KG se Product description MULLER lektronik System requirements 3 3 System requirements The following requirements must
26. K i 3 0x00000000000000 3 Click on the desired machine or eguipment on the list For instance a tractor with which you wish to pull a sprayer 74 Copyright M ller Elektronik GmbH 8 Co KG TaskManager application M LLER lektronik Step 4 Starting a task gt The following screen will appear 8 ME ME_ISO_SPRAYER 02 03 2011 07 57 44 on tractor 1 OMA AAI Wastes gt You will find the following information below the name of the machine For activated machines Date and time of activation For deactivated machines Date and time of deactivation 4 Add additional machines or farm equipment gt You have selected a machine Procedure 2 You can reactivate a deactivated machine as follows 1 Click on the following line on the Task data screen 2 Select a deactivated machine from the list we 3 LA Press and hold for 3 seconds gt Machine will be activated 6 9 2 Selecting a worker This step reguires that you select the workers who will process the task You can add any number of workers The terminal records the length of time worked by the workers you added sono _ Add worker grey asterisk next to the image of the worker _ End worker s shift red x next to the image of the worker Icons Workers can be activated or deactivated The terminal will calculate the amount of time worked by the workers you activated The icon preceding the name
27. LLER M lektronik Installation and operating instructions BASIC Terminal TOP Version 20110308 30322521 02 EN Read and follow these operating instructions Keep these operating instructions in a safe place for later reference Imprint Document Copyright Installation and operating instructions Product BASIC Terminal TOP Document number 30322521 02 EN Valid for item number 30322521 30322522 From software version 3 68 Original language German M ller Elektronik GmbH 8 Co KG Franz Kleine Stra e 18 33154 Salzkotten Germany Phone 49 0 5258 9834 0 Fax 49 0 5258 9834 90 Email info mueller elektronik de Homepage http www mueller elektronik de s Contents M LLER lektronik Contents 1 For your safety 7 1 1 Basic safety instructions 7 1 2 Layout and meaning of warnings T 1 3 User requirements 8 1 4 Intended use 8 1 5 EC declaration of conformity 8 2 About these Operating Instructions 9 2 1 Target group of these Operating Instructions 9 2 2 Layout of operating instructions 9 2 3 Layout of references 9 3 Product description 10 3 1 Performance description 10 3 2 Scope of delivery 10 3 3 System requirements 11 3 4 Correctly interpreting information on the nameplate 11 4 Mounting and installation 12 4 1 Instructions on retrofitting 12 4 2 Mounting the terminal in the tractor cab 13 4 2 1 Screwing on the GSM antenna 13 4 2 2 Terminal ports 14 4 3 Connecting the terminal
28. Only for terminals with a GSM modem CAN bus port installed To connect a working position sensor for Item no 30322522 TRACK Leader 2 4 Port for analogue camera 9 Port A Only for terminals with a GSM modem CAN bus port installed To connect the ISOBUS basic equipment Item no 30322522 5 Covering cap for USB port Port C Prevents dust from entering the USB socket Serial port RS232 4 3 Connecting the terminal to the basic eguipment Risk of damage when using non standard basic eguipment Connecting the terminal to non standard basic eguipment may damage both the terminal and the basic equipment o Before connecting the terminal to any existing basic equipment check that the equipment conforms to ISO 11783 o gt Do not connect the terminal to any basic equipment that does not comply with ISO 11783 14 Copyright Muller Elektronik GmbH amp Co KG m Mounting and installation MULLER A lektronik Connecting the terminal to the basic eguipment 4 3 1 Checking the ISOBUS compatibility of the basic equipment The basic equipment provided by Muller Elektronik is ISO 11783 compatible and labelled with the following sticker on the ISOBUS socket 4 3 2 Selecting the correct basic equipment You must select basic equipment that matches the fittings of the vehicle in which the terminal BASIC Terminal TOP is to be installed The following types of basic equipment are available Basic equipment for ISOBUS tractors Basi
29. Setting up the operation mode for the TaskManager application The TaskManager application can be run in two different modes ISO mode SC mode In ISO mode the TaskManager will have full functionality However the TaskManager s functionality is limited in SC mode Use this mode when you are not using the TaskManager 54 Copyright M ller Elektronik GmbH amp Co KG TaskManager application MULLER lektronik Display layout in the TaskManager application Features of SC mode The parameters of the machine will be reloaded every time the terminal is restarted When you open the TaskManager in SC mode only the name of the connected machine will be shown on the display Procedure You can change the mode of the TaskManager application as follows 1 Switch to the Settings screen TaskManager gt The following screen will appear Settings GPS Receiver offset Offset X KIT cm Offset Y Gem h Operation mode 2 E Select and click on the Operation mode line gt The mode will change with each click 3 Setthe desired mode 4 Restart terminal gt The set mode will be activated after restart 8 4 Display layout in the TaskManager application There are three important screens in the TaskManager application which you need to get to know Master data screen gt 55 Task list screen gt 56 Task data screen gt 58 8 4 1 Mast
30. Signal TxD Operating voltage minus 0 7 volt GND DSR RTS CTS A When switched on the terminal routes current to the farm equipment that is connected via the RS232 connector The voltage of the RS232 connector is dependent on the operating voltage of the terminal When connected to a 12 V battery the terminal will transfer approx 11 3 V to the connected equipment When connected to a 24 V battery the terminal will transfer approx 23 3 V to the connected equipment The use of a GPS Receiver only requires the signals RxD and TxD as well as GND 9 4 4 Pin assignment of camera ports 1 and 2 Ports 1 and 2 are used to connect an analogue camera The pin assignment is identical for both ports Ports 1 and 2 are 5 pin A encoded M12 sockets Please refer to the following table for the pin Pin assignment of the socket in Pin assignment of the connector the terminal Pin is exclusively intended for use by ME do not connect anything Pin is exclusively intended for use by ME do not connect anything 88 Copyright M ller Elektronik GmbH amp Co KG Maintenance and servicing Memi _ lektronik Technical specifications Copyright Muller Elektronik GmbH amp Co KG 89 Notes M LLER lektronik 10 Notes 90 Copyright M ller Elektronik GmbH 8 Co KG
31. assigned the task to a customer Selecting a farm business Procedure 1 Click on the following line and hold for two seconds gt A list of available farms will appear gt The list only contain farms that belong to the selected customer 2 Click on the desired farm gt The selected farm will appear on the Task data screen gt You have assigned the task to a farm Selecting a field Procedure 1 Click on the following line and hold for two seconds gt A listof available fields will appear gt The list only contains fields that belong to the selected farm 2 Select the desired field gt The selected field will appear on the Task data screen Copyright Muller Elektronik GmbH amp Co KG 69 TaskManager application Step 3 Entering and saving task data M LLER lektronik gt You have assigned the task to a field Selecting a person in charge Procedure 1 Click on the following line and hold for two seconds A gt A listof available people will appear 2 Selectthe desired person gt The name of the person will appear on the Task data screen gt You have assigned the task to a person Selecting rate and mix Icons You will see two icons on the screen Mix Name of the mix to be spread E Product If the mix is composed of several products you can specify the individual products here To the right of each icon there are three input fields each of
32. atus of the function is displayed on the icon G Function activated Function deactivated 5 Click on Storage location Copyright Muller Elektronik GmbH amp Co KG 41 Configuring the terminal in the Service application Activating the Diagnostics function Memon J er gt The line will be highlighted with a frame 6 Select USB to save screenshots on the USB flash drive 7 Select Portal to send screenshots to the FarmPilot portal 7 12 2 Creating screenshots Procedure M You have configured the Screenshots function M If you want to save the screenshots to the USB flash drive you will already have inserted the USB flash drive into the terminal 1 Open any screen 2 Press and hold the following keys briefly in the order depicted Gp lt gt gt While the screenshot is being captured the icon of a photo camera will be displayed in the centre of the display gt When the camera icon disappears the screenshot has been created gt You will find the screenshot you captured in the location you specified as the Storage location The USB flash drive saves the screenshots in the folder ScreenCopy 7 13 Activating the Diagnostics function To activate the Diagnostics function you must first activate its driver Procedure 1 Switch to the Driver settings screen Service Driver settings gt The following screen will appear 5 t Diagnostics
33. ave been fully completed Therefore only stop a task if you have completed it Stopped tasks are displayed as completed tasks in the FarmPilot portal Tasks processed by the Master M All tasks processed by the fleet leader Master will be labelled as such Copyright M ller Elektronik GmbH amp Co KG 57 TaskManager application M LLE LER Exporting machine settings for the Farm Management Information System Every time the Master starts to process a new task you will be notified by a pop up window 8 4 3 Task data screen On the Task data screen you can find all the information about the selected task The Task data screen will be displayed when you select or create a task on the Task list screen You can identify the Task data screen by this icon You will find the icon in the upper section of the screen The colour of the icon will vary depending on whether the task has been started or newly created Green the task displayed has been started Yellow the task displayed has not been started ORo TEN fertilization 2 00 Field 2 Ga l Mueller 5 2 00 Field 2 i dit ME ISO SPRAYER ok Task data screen 1 Name and number of the task 4 Cursor Serial task number Selects a line that you can click on using the TSK means TASK rotary knob 2 Task processing stage Function icons section Indicates what stage of completion the task is Icons that can be pre
34. be met for the tractor to be used in conjunction with the terminal The tractor must be ISOBUS capable If your tractor is not ISOBUS capable you can upgrade it Our staff will be glad to advise you on selecting compatible components Requirements for the Farm Management Information System In order to use the data from the TaskManager application with the Farm Management Information System The Farm Management Information System must be ISO XML capable System requirements for using the FarmPilot portal To use the FarmPilot portal you will require a terminal with a built in GSM modem The following terminals are currently equipped with a modem BASIC Terminal GSM item no 30322512 BASIC Terminal TOP GSM item no 30322522 COMFORT Terminal GSM item no 30322527 If you bought a terminal without a GSM modem you can retrofit it with a GSM modem later Please call our Customer Services department 3 4 Correctly interpreting information on the nameplate On the reverse of the terminal you will find a nameplate sticker On this sticker you can find all the information you need to definitively identify the product Have these details ready when you contact Customer Services M LLER fa MeL ER ON www mueller elektronik de Bo K Nr DC 11 15V 2 uw Sw 14 01 00 5 ME NR 302531 SN M01 245 IDA TE Nameplate on the reverse of the terminal 1 Customer number 4 Operating voltage If the
35. c equipment for tractors without signal capture Basic equipment for retrofitting tractors and for signal capture Basic equipment for ISOBUS tractors Item name Basic equipment BASIC Terminal TOP for ISOBUS tractors ISO 11783 with ISOBUS terminal connector Item no 30322541 Suitable for Tractors with a power socket for connecting the ISOBUS basic equipment The power socket must conform to ISO 11783 In this case only one connecting cable is required to link the terminal to the tractor bus and the power supply Basic equipment for tractors without signal capture Item name Basic equipment BASIC Terminal TOP without tractor jobcomputer Item no 30322550 Suitable for Tractors without signal capture Basic equipment for retrofitting tractors and for signal capture Item name Basic equipment BASIC Terminal TOP with tractor jobcomputer Suitable for retrofitting tractors and for signal capture Copyright Muller Elektronik GmbH amp Co KG 15 Mounting and installation MULLE lektronik SIM card This basic eguipment is available in two models Connection via an adapter cable to the tractor s existing signal socket DIN 9684 1 ISO 11786 Item no 30322560 Equipping the tractor jobcomputer with sensors km h transmission km h radar PTO speed and work position This equipment offers the possibility of fitting the tractor with a front and rear power socket Item no 30322565
36. copy tasks that have already been started 4 Return to the Task list screen gt The following screen will appear illfertilization 2 00 Field 2 fertilization 2 00 Field 2 t Mueller SS 2 00 Field 2 Worker The task must be marked with the following icon B Task started l 5 Split task gt The following notification will appear Split task 6 Confirm Copyright M ller Elektronik GmbH amp Co KG 67 TaskManager application Step 3 Entering and saving task data M LLER lektronik gt The following screen will appear E fertilization 2 00 Field 2 Hf fertilization 2 00 Field 2 fertilization 2 00 Field 2 t Mueller SS 2 00 Field 2 tn Worker A new task will appear on the Task list screen The task is marked with an asterisk This task is the unprocessed portion of the original task It contains all the data from the original task In particular the field boundaries and obstacles from SECTION Control gt You have split the task and created a copy You now have the following options You can alter the rates and products for this task gt 70 8 8 Step 3 Entering and saving task data Task data are entered in two different locations In the Farm Management Information System Inthe TaskManager application In the TaskManager application you can only select data which you have previously created in the Farm Mana
37. ct to this satellite in the first instance 38 Copyright Muller Elektronik GmbH amp Co KG ki Configuring the terminal in the Service application M LLER lektronik GPS Receiver satellite 2 secondary DGPS satellite The DGPS Receiver will only connect to this satellite in the event that the primary satellite fails Your satellite selection will depend on which satellite currently has the best availability in your region Auto The software automatically selects the current best satellite This setting is not recommended as it slows down start up of the DGPS Receiver Name of the satellite Steering This parameter activates the Automatic steering assistance function in the GPS Receiver On Activates automatic steering assistance Off Deactivates automatic steering assistance Correction signal Type of correction signal for the DGPS Receiver WAAS EGNOS Correction signal in Europe and in North America E DIF Internal calculation of correction data This setting is required outside of the EU and the USA To use e Dif you will require a special version of the DGPS Receiver A100 You can order this this DGPS Receiver from Muller Elektronik with the item number 30302464 Terrain compensation Under this parameter the terrain compensation GPS TILT Module is configured You can order the terrain compensation from Muller Elektronik with the following item number 30302495 Controls
38. cted will be started 4 JON Stop task gt The task will be stopped gt The original task will be marked yellow on the Task list screen B plant protection 1 00 Field 1 E plant protection 2 00 Field 2 plant protection 1 00 Field 1 Et M ller SS 1 00 Field 1 Worker gt The paused task is now marked yellow 82 Copyright Muller Elektronik GmbH amp Co KG TaskManager application M LLER lektronik Step 7 Transferring completed tasks to the Farm Management Information System 8 12 Step 7 Transferring completed tasks to the Farm Management Information System When you have finished processing a task or set of tasks you can export the completed tasks from the terminal for further processing and evaluation The following options are available to you Transfer tasks to the Farm Management Information System using a USB flash drive Send a set of tasks to the FarmPilot portal 8 12 1 Transferring tasks using a USB flash drive Procedure M You have completed all tasks M All tasks are marked red on the task list 1 Open the Master data screen Write task data to the USB flash drive 2 gt Wait until the icon Jdisappears and the LED on the USB flash drive stops flashing 3 Remove the USB flash drive 4 Connect the USB flash drive to the farm computer 5 Import and process data with the Farm Management Information System 8 12 2 Uploa
39. cted worker has been added and activated gt You will find the following information below the name of the worker For activated workers Date and time of activation For deactivated workers Date and time of deactivation gt You have selected a worker 8 10 Step 5 Using the TaskManager application during work 8 10 1 Entering a change of shift Procedure 1 Click on the following line on the Task data screen 2 End the active worker s shift gt The amount of time worked by the worker will no longer be recorded from now on Add worker gt A list of names of available workers will appear If the name of the desired worker does not appear the worker has not yet been created in the Farm Management Information System 4 Click on the desired worker on the list gt The worker will be added to the task gt The counters will begin to record the length of time spent working gt You have selected a worker 8 10 2 Altering rates Procedure 1 Click on the following line on the Task data screen 2 Click on the first field next to the icon E 3 Enter the desired rate Copyright M ller Elektronik GmbH amp Co KG 77 TaskManager application M LLER lektronik Step 5 Using the TaskManager application during work VI 4 a Confirm and save your entry gt The machine will adopt the rate 8 10 3 Selecting the task processing phase Setting the task processing phase allo
40. d Password for the GPRS connection Controls Retrieve default values Procedure You can configure the mobile connection as follows M You have inserted the SIM card 50 Copyright Muller Elektronik GmbH amp Co KG ki Configuring the terminal in the Service application M LLER wu lektronik Configuring FarmPilot M You have activated the FarmPilot portal 1 Switch to the configuration screen for the GPRS connection oo M gt The following screen will appear T Provider Country Germany Provider D2 Vodafone Apn web vodafone de Dnsl 139 7 30 125 2 Set GPRS connection parameters Copyright Muller Elektronik GmbH amp Co KG 91 TaskManager application Starting the TaskManager application Memon J er 8 TaskManager application In this chapter you will learn how to process tasks using the TaskManager application These instructions follow a chronological order Study the chapters in sequence and follow the operating instructions The TaskManager application complies with part 10 of the ISOBUS standard ISO 11783 The version described here supports the following functions Creating tasks on the terminal Viewing and processing tasks that have been planned using the Farm Management Information system Processing tasks with attached application cards Transferring the prescribed rate to the machine Documenting tasks The type of documente
41. d data varies according to the machine Exporting current spread rates and transferring them to the farm computer for evaluation Recording complete task data Exchanging task data between the FarmPilot portal and the TaskManager 8 1 Starting the TaskManager application Procedure 1 Insert an empty USB flash drive into the terminal 2 Open the Selection menu application gt The following screen will appear Service ur 2x26 ExNEBBLDBBACABBABF H A sS7h2de TS L 0x87 0xN8C83999C488004 tt TaskManager OxF7 xneegs2a09C4a000F TRACK Leader xiC 9xAG8817808C 48 8AGF an 3 Click on the TaskManager line 52 gt The following screen will appear We Fields Farms EM Customers s Farm equipment ME P TM V 02 00 60 TC 00 15 04 Copyright M ller Elektronik GmbH 8 Co KG M LLER lektronik TaskManager application Controls in the TaskManager application gt The TaskManager application has been started 6 2 Controls in the TaskManager application The TaskManager application is controlled using the rotary knob and the function keys In this chapter you will find an overview of all function icons that you may come across in the TaskManager application Controls Copyright M ller Elektronik GmbH amp Co KG Switch to the Task data screen if a task has been sta
42. dated two to three times per minute The counters displayed depend on which machine is connected Displaying the counters of a machine 1 Switch to the Task data screen 2 Click on the following line on the Task data screen gt A screen will appear with the selected machines 3 Click on the desired machine gt The counters of the machine you clicked on will appear on the Task data screen Documenting filling and emptying With ISO machines filling and emptying are automatically documented With non ISO machines you can document filling and emptying using the TaskManager application You can evaluate the documented values in the FarmPilot portal After weighing a tipper truck the driver can enter that he has loaded 20 tonnes of maize After spreading 5000 litres of manure with a non ISO manure truck the driver can enter the quantity spread as emptying Thus you can document the filling or emptying of a container for non ISO machines M You have started a task 1 Open the Task list screen Copyright Muller Elektronik GmbH amp Co KG 79 TaskManager application Step 5 Using the TaskManager application during work M LLER lektronik 2 Click on the following line Filling Emptying gt The following screen will appear i i 3 Press the desired function key Va Enter filled capacity ce Enter emptied capacity gt The following scr
43. ding a set of tasks to the FarmPilot portal Procedure M You have received the processed tasks via FarmPilot M You have completed all tasks All tasks are marked red on the task list 1 Open the Master data screen gt The following screen will appear 29 Farms je Customers s Farm equipment ME TM V 02 00 60 TEN 00301 A 4 Upload a set of tasks to the FarmPilot portal Copyright Muller Elektronik GmbH amp Co KG 83 TaskManager application Important files stored on the USB flash drive M LLER lektronik gt The following notification will appear Start uploading task data a 3 Confirm gt The data are being loaded gt The transferred task data will no longer be displayed on the terminal gt Anew folder is being created on the USB flash drive TaskData_work serial number Backup copies of the tasks sent to the FarmPilot portal will be created in this folder gt You have uploaded a set of tasks to the portal 8 13 Important files stored on the USB flash drive Important files Important folders 84 All task data field data and machine data will be saved on the USB flash drive This makes it possible to transfer these data between the terminal and the Farm Management Information System All files have standardised names which may not be altered The folders that must be stored on the USB flash drive vary depending on whether you are using the t
44. e 5 Slide the SIM card into the card holder Following installation the chip on the card must be in contact with the circuit board The card must be positioned as shown in the picture 7 Press the card holder lightly onto the circuit board until it clicks into place on the right hand side 8 CAUTION Tighten the screws but not too tight otherwise the cover might be damaged Copyright Muller Elektronik GmbH amp Co KG 17 Mounting and installation GPS Receiver M LLER lektronik 4 5 9 Screw the cover back on Make sure that the rubber seal is positioned between the cover and the casing GPS Receiver The GPS Receiver gathers and transmits information about the position of the machine to the connected terminal Technical requirements for using the DGPS Receiver Operating voltage Supply voltage of the terminal 1 5 V Current consumption Maximum of 200 mA at 70 C without any additional load from other appliances the current consumption of the multifunctional grip and LightBar have already been taken into account in this specification GPS standard NMEA 0183 Refresh rates and signals 5 Hz GPGGA GPVTG 1 Hz GPGSA GPZDA a pa Copyright M ller Elektronik GmbH 8 Co KG m Mounting and installation M LLER lektronik GPS Receiver 4 5 1 Connecting the GPS Receiver to the terminal Damage to the equipment caused by short circuit Pin 4 of port C is live The voltage d
45. een will appear gt You can identify whether you are entering the filled capacity or the emptied capacity by the icon in the upper left hand corner 4 The screen consists of three columns in which you can enter data In the left hand column Enter capacity In the middle column Enter the unit litres t tonnes In the right hand column Select from a list the product to be filled or emptied 5 5 Exit screen 6 The following notification will appear Save changes 7 Click Yes to confirm gt The Task data screen will appear 80 Copyright M ller Elektronik GmbH amp Co KG M LLER lektronik TaskManager application Step 6 Stopping work 8 10 7 Procedure 8 11 8 11 1 Procedure 8 11 2 Procedure Exiting the TaskManager application You can exit the TaskManager application at any time This will neither finish nor cancel the tasks 1 Open the Selection menu application gt The selection menu will appear 2 Startthe desired application Step 6 Stopping work You can stop a task at any time You must decide yourself whether this task has been fully processed or must be processed further If you stop the work you must decide what should happen to the task Depending on whether the task was fully processed or must be processed further you have the following options Stop task Pause task Stopping a task When you stop a task FarmPilot will consid
46. eiver When you have mounted and connected the GPS Receiver you must enter its exact position The position of the GPS Receiver is also referred to as the GPS Receiver offset In order to enter an accurate position for the GPS Receiver you must measure the distances of the GPS Receiver from the longitudinal axis and from the so called reference point gt 20 When entering distances please note that it is essential to specify whether the GPS Receiver is to the left or right of the machine s longitudinal axis and whether it is positioned before or after the reference point Copyright Muller Elektronik GmbH amp Co KG 19 Mounting and installation GPS Receiver M LLER lektronik What is the position of the GPS Receiver The distance should be entered as follows to the right of the longitudinal axis before the reference point Procedure 1 Switch to the Settings screen TaskManager gt The following screen will appear to the left of the longitudinal axis X Settings GPS Receiver offset Offset X BE cm Offset Y O cm Ey Operation mode 2 Measuring the position ofthe GPS Receiver You will find out how to do this in the following subchapters 3 Enter the distances measured in the fields Offset X and Offset Y For machines fitted with an ISO jobcomputer On the following illustration distances are marked which must be measured for each different machine
47. epends on the operating voltage of the terminal and is used to supply the DGPS Receiver A100 from M ller Elektronik Other GPS Receivers may suffer damage if connected to this port Before connecting a different GPS Receiver Check what voltage the terminal is connected to 12 V or 24 V Check the pin assignment ofthe GPS Receiver Check the allowable voltage for the GPS Receiver Compare the terminal voltage to the allowable voltage for the GPS Receiver Compare the pin assignment Only connect the GPS Receiver to the terminal if the voltage range and pin assignment of both devices don t differ from each other The DGPS Receiver A100 has a status LED which shows the quality ofthe connection red The DGPS Receiver is connected to the terminal but has no GPS reception orange GPS reception is working green DGPS reception is working During initial start up it can take approx 30 minutes until the GPS Receiver has reception At subsequent start ups it will only take approx 1 2 minutes Procedure M The GPS Receiver is mounted on the roof of the tractor 1 Switch off the terminal 2 Guide the connection cable from the GPS Receiver into the cab 3 CAUTION Ensure that the cable is not laid across sharp edges or at risk of becoming bent Lay the cable in a place where nobody can trip over it 4 Connect the connecting cable of the GPS Receiver to port C on the terminal 4 5 2 Entering the position of the GPS Rec
48. er data screen The Master data screen is the start screen for the TaskManager application From this screen you can access all other screens You can identify the Master data screen by this icon You will find the icon in the upper section of the screen Copyright Muller Elektronik GmbH amp Co KG 55 TaskManager application M LLE LER Display layout in the TaskManager application af We Fields os Farms EM Customers si Farm equipment ME TM V 02 00 60 TCV 001301 Master data screen In the main section of this screen you will see folders which contain the data stored in the Farm Management Information System If you move the cursor right down to the bottom using the rotary knob you will be able to see additional folders containing master data 8 4 2 Task list screen The Task list screen contains the names of all tasks stored on the USB flash drive You can identify the Task list screen by this icon You will find the icon in the upper section of the screen plant protection 1 00 Field 1 E plant protection 2 00 Field 2 7 plant protection 4 00 Field 4 E plant protection 5 00 Field 5 plant protection 1 00 Field 1 ig M ller SS 1 00 Field 1 ka Worker Task list screen Beneath the task list you will find the background information about the respective task you selected You can identify the status of the task by the colour of the ico
49. er responsibility When retrofitting a machine with electrical and electronic farm equipment and or components connected to the vehicle s electrical system it is your own responsibility to check whether the installation causes interference with the vehicle s electronic system or other components This applies in particular to the electronic control of EHR front linkage take off shafts engine gear Additional requirements The following requirements must be met in order to retrofit mobile communication systems e g radio phone All farm equipment must be approved and installed in accordance with the regulations applicable in the respective country e g in Germany the Federal Approvals Office for Telecommunications BZT The equipment must be installed as a fixed installation The operation of portable or mobile farm equipment in the interior of the vehicle is only permitted via a connection to a permanently installed exterior antenna The transmitting part must be spatially separated from the vehicle s electronic system When attaching the antenna pay attention to proper installation including a sound ground connection between the antenna and the vehicle s ground wire For information on wiring and installation as well as the maximum allowable current consumption please also refer to the installation guide provided by the machine manufacturer 12 Copyright Muller Elektronik GmbH amp Co KG Moun
50. er this task to be fully completed Therefore you should only stop tasks if they have been completed 1 Switch to the Task data screen 2 u Stop task gt The task will be stopped gt The task will be marked red on the Task list screen Pausing a task You can pause a task if you need to interrupt your work but have not yet completed the task A task will only be paused if you start another task M You have started a task and are on the Task data screen Bebe E plant protection 2 00 Field 2 i Mueller SS 2 00 Field 2 skt ME_ISO_SPRAYER Volume counter 232 00 Surface counter 1 15 ha Distance counter 0 48 km Time counter 0 04 h 1 Switch to the Task list screen while the task is started Copyright Muller Elektronik GmbH amp Co KG 81 TaskManager application M LLER lektronik Step 6 Stopping work gt The following screen will appear Ei plant protection 1 00 Field 1 E plant protection 2 00 Field 2 plant protection 1 00 Field 1 t M ller SS 1 00 Field 1 Worker The active task is marked green 2 Click on any task preferably one that has been stopped gt The following screen will appear MES TE E plant protection 1 00 Field 1 ig M ller SS 1 00 Field 1 ih Worker as 202 00 I ha Mix Water AVENTIS C 3 ME_ISO_SPRAYER Worker 3 es Start task gt The active task will be paused and the task you have sele
51. er will send you the task data gt The following notification will appear New task data available Copyright Muller Elektronik GmbH amp Co KG 61 TaskManager application Step 2 Selecting a task to process M LLER lektronik 2 Confirm gt The data are not on the terminal yet but are ready to be downloaded q 3 2 Load the data from the portal the arrow on the icon must point downwards gt The following notification will appear Start downloading task data 4 Confirm gt The data are being loaded 5 Open the Task list screen gt All tasks from the set of tasks will appear on the Task list screen gt You have received a set of tasks from the dispatcher You can process the tasks from the set of tasks 6 7 Step 2 Selecting a task to process Before you start working you must first select the task you wish to process The following options are available to you Create a new task on the terminal Resume an existing task 8 7 1 Creating a new task on the terminal You can create a new task directly on the terminal When creating a task directly on the terminal you will not need to fill it with task data right away You can process a task and then enter into the Farm Management Information System what you have done and on which field The following options are available to you Create a new task on the terminal Copy an existing task and save t
52. erminal in conjunction with the FarmPilot portal or transfering the data from the Farm Management Information System using a USB flash drive The files specified here may appear in various folders TASKDATA xml A file containing all task data stored in the Farm Management Information System The file will be saved from the Farm Management Information System either onto the hard drive of the farm computer or onto a USB flash drive When using the FarmPilot portal the file will automatically be created in the folder TaskData work When working without the FarmPilot portal you must copy the file from the hard drive to the folder TASK DATA on the USB flash drive The Taskdata xml file must not be larger than 2 MB Files that are too large may cause problems during data transfer and slow down the terminal considerably GRD number bin A file containing the application cards for a field If you wish to use the task manager in combination with application cards you must transfer this file to the terminal as well TaskData A folder containing all tasks of a set of tasks that are currently being processed This folder will only be required if you use the TaskManager application without FarmPilot Also read the chapter Creating a Task data folder on the USB flash drive gt 61 TaskData work A folder containing all tasks of a set of tasks that are currently being processed This folder will be created automatically when
53. es for full versions of the software MULLER lektronik gt The following screen will appear E Wee ener TRACK Leader FIELD Nav E 2 Click on the desired plugin gt The icon preceding the name of the plugin indicates whether the plugin is activated or deactivated 3 EI Exit screen gt The following notification will appear Changes will be adopted after restart 4 Confirm 5 Restart terminal gt All activated plugins will appear in the selection menu 7 7 Activating licences for full versions of the software Several applications are pre installed on the terminal which you can use for trial purposes for up to 50 hours After this time has elapsed they will be automatically deactivated The amount of free usage time remaining is shown in brackets next to the name of the application To activate a licence you will require an activation number which you will receive on purchasing an application from M ller Elektronik If you request the activation number by phone or by email you will be required to give our staff the following information Code Found under the name of the application on the Licence management screen Serial number of the terminal Found on the nameplate on the reverse of the terminal tem number of the terminal Found on the nameplate on the reverse of the terminal Procedure The activation number is entered as follows 1 Switch
54. g a task 64 8 7 2 Adopting an existing task 65 Resuming a task 65 Splitting an order that has already been started 66 8 8 Step 3 Entering and saving task data 68 8 8 1 Entering task data 68 Selecting a customer 69 Selecting a farm business 69 Selecting a field 69 Selecting a person in charge 70 Selecting rate and mix 70 Measure 71 8 8 2 Saving task data 71 8 9 Step 4 Starting a task 72 8 9 1 Selecting the machine 73 8 9 2 Selecting a worker 75 8 10 Step 5 Using the TaskManager application during work 1 8 10 1 Entering a change of shift 7 8 10 2 Altering rates 11 8 10 3 Selecting the task processing phase 78 8 10 4 Evaluating counters 78 8 10 5 Displaying the counters of a machine 79 8 10 6 Documenting filling and emptying 79 8 10 7 Exiting the TaskManager application 81 8 11 Step 6 Stopping work 81 8 11 1 Stopping a task 81 8 11 2 Pausing a task 81 8 12 Step 7 Transferring completed tasks to the Farm Management Information System 83 8 12 1 Transferring tasks using a USB flash drive 83 8 12 2 Uploading a set of tasks to the FarmPilot portal 83 8 13 Important files stored on the USB flash drive 84 9 Maintenance and servicing 85 9 1 Servicing and cleaning the terminal 85 9 2 Disposing of the unit 85 9 3 Checking the software version 85 9 4 Technical specifications 85 9 4 1 Technical specifications of the terminal 85 Copyright Muller Elektronik GmbH amp Co KG 5 Contents M LLER lektronik 9 4 2 Pin assig
55. gement Information System You can assign these data to the individual tasks You can only alter the task data of a task if you have created a new task and have not saved it yet 8 8 1 Entering task data You can only enter the task data that you have created in the Farm Management Information System and saved on your USB flash drive The task data created in the Farm Management Information System will be saved in the following categories Name of the category Customer Worker Cannot be selected until the task has been started 68 Copyright M ller Elektronik GmbH amp Co KG eon se TaskManager application MULLER lektronik Step 3 Entering and saving task data Machine Cannot be selected until the task has been started Ss DE The names used here may not always correspond to the category names used in the Farm Management Information System This is due to the fact that the names vary with each specific Farm Management Information System used For instance if you did not create any data in a particular category the following screen will appear F4 Depending on the category a different struck through icon may appear Selecting a customer Procedure 1 Click on the following line and hold for two seconds gt A listof available customers will appear 2 Select customers from the list gt The name ofthe selected customer will appear on the Task data screen gt You have
56. he copy as a new task Creating a new task Procedure 1 Switch to the Master data screen 62 Copyright Muller Elektronik GmbH amp Co KG TaskManager application M LLER lektronik Step 2 Selecting a task to process gt The following screen will appear We Fields f 28 Farms EM Customers s Farm equipment ME TM V 02 00 60 TC v 00 13 01 2 Click on the Tasks line gt The following screen will appear Hffertilization 2 00 Field 2 fertilization 2 00 Field 2 ti Mueller A 2 00 Field 2 tn Worker The Task list screen may show tasks that have already been created as shown in the picture 3 EL Create a new task gt The following screen will appear NE TSK 2011 02 23 16 38 46 gt The new task was named by the terminal with the current date and time The task has not been saved yet gt You have created a new task You now have the following options You can fill the task with task data gt 68 You can start the task gt 72 You can save the task gt 71 Copyright Muller Elektronik GmbH amp Co KG 63 TaskManager application Step 2 Selecting a task to process Memon J pf Copying a task You will not always have to create a new task In most cases it is advisable to copy an existing task and save the copy as a new task The copy of the task contains all the field boundaries and application cards of
57. he display The display of the terminal BASIC Terminal TOP is split into two sections A different application is diplayed in each section This allows you for example to control the tractor on the field and monitor the field sprayer at the same time This means that you will not need an additional terminal TE aI ah i LO sree m gt a x Ela id le H H i H 4 2 Segmentation of the display Header section used to display information 2 Main display section used for control The header allows you to display information The main display shows the application about an application currently running function icons and the information you need to control the application that is currently running Copyright M ller Elektronik GmbH amp Co KG 27 Opening applications in the selection menu M LLER lektronik In the selection menu you can see which applications can be run with the split display Segmentation of the display Controls Swap applications between the header section and the main section of the display 28 Copyright M ller Elektronik GmbH 8 Co KG ki Configuring the terminal in the Service application M LLER lektronik Controls in the Service application 7 7 1 Controls Configuring the terminal in the Service application In the Service application you can configure the terminal and activate the connected farm equipment
58. loaded to the portal 3 Wait until the Sending DeviceldentData notification disappears gt The data have been uploaded to the portal 4 Ifthe process is taking too long you can cancel the data transfer 5 Cancel data transfer 7 13 2 CAN Trace settings CAN Trace is a function that logs the data exchange between the terminal and the connected jobcomputers Customer Services can use the logged data for diagnostic purposes should any errors arise in the system If an error occurs when using the terminal Customer Services may ask you to activate the CAN Trace function Only activate this function if prompted to do so by Customer Services Procedure 1 Switch to the CAN Trace settings screen CD Service Gi LE CAN Trace settings 1 Click on Duration min Copyright M ller Elektronik GmbH 8 Co KG 43 Configuring the terminal in the Service application Activating an external LightBar M LLER lektronik 2 Setthe duration Specify for how long communication should be logged after the terminal has been restarted Communication can be logged for a duration of one to five minutes 3 Click on Storage location 4 Selectthe storage location 5 Select USB to save data on the USB flash drive The USB flash drive must be inserted in the terminal 6 Select Portal to send data to the FarmPilot portal FarmPilot must be activated before data can pe transferred 7 Click on Activate C
59. m and the FarmPilot portal You must add and export each machine to the master data and the Farm Management Information system Procedure M You have connected the terminal to the jobcomputer of the machine that you wish to add to the master data M You have configured the machine 1 Insert an empty USB flash drive into the terminal 2 Create a Task data folder on the USB flash drive gt 61 3 Create a new task gt 62 You do not need to enter any task data for this task 4 Start task gt 72 gt The following screen will appear KG F 2011 02 24 08 16 56 arene ae ME_ECO_Spritze 5 Wait several minutes until the counters appear gt The following screen will appear 0 IELGI E 2011 02 24 08 16 56 skt ME ECO Spritze Volume counter 12 00 Surface counter 0 05 ha Distance counter 0 02 km Time counter 0 00 h Copyright M ller Elektronik GmbH 8 Co KG 59 TaskManager application MULLE lektronik Step 1 Transferring data from the Farm Management Information System to the terminal 6 JON Stop task T D Switch to the Master data screen e 8 Save the data on the USB flash drive gt The machine data are saved to the Taskdata xmi file located in the Task data folder on the USB flash drive 9 Waituntil the data have been written and read e gt The function icon will be hidden 10 Remove the USB flash drive from the ter
60. minal gt You have transferred the machine parameters to the USB flash drive According to whether you wish to export machine data create a new machine or update the parameters of an existing machine you must proceed with the Farm Management Information System in various ways Follow the manual for your Farm Management Information System If you create more than one entry for a machine in the Farm Management Information System this can later lead to errors in the TaskManager o Only create one entry per machine in the Farm Management Information System 6 6 Step 1 Transferring data from the Farm Management Information System to the terminal You can transfer the data from the Farm Management Information System to the terminal in the following ways using a USB flash drive via the FarmPilot portal 8 6 1 Transferring data using a USB flash drive Procedure M You have created the Task data folder on the USB flash drive M The Task data folder contains the file Taskdata xml 1 Start the TaskManager application TaskManager 2 Insert the USB flash drive into the terminal gt The following notification will appear Copying task data gt The task processed most recently will be started automatically 60 Copyright M ller Elektronik GmbH 8 Co KG TaskManager application M LLER lektronik Step 1 Transferring data from the Farm Management Information System to the terminal
61. mpensation 40 7 12 Screenshots 41 7 12 1 Configuring the screenshots function 41 7 12 2 Creating screenshots 42 7 13 Activating the Diagnostics function 42 1 13 1 Jobcomputer diagnostics 43 Sending diagnostic data to the portal 43 7 13 2 CAN Trace settings 43 7 14 Activating an external LightBar 44 7 15 Camera 45 1 15 1 Activating a camera 45 7 15 2 Operating the camera 46 7 16 Configuring FarmPilot 47 7 16 1 Activating FarmPilot 47 7 16 2 Configuring the connection with FarmPilot 48 7 16 3 Entering data in the FarmPilot access data section 49 7 16 4 Configuring the GPRS connection manually 50 8 TaskManager application 52 8 1 Starting the TaskManager application 52 8 2 Controls in the TaskManager application 53 8 3 Setting up the operation mode for the TaskManager application 54 8 4 Display layout in the TaskManager application 55 8 4 1 Master data screen 55 8 4 2 Task list screen 56 4 Copyright M ller Elektronik GmbH amp Co KG Contents MULLER lektronik 8 4 3 Task data screen 08 8 5 Exporting machine settings for the Farm Management Information System 58 8 6 Step 1 Transferring data from the Farm Management Information System to the terminal 60 8 6 1 Transferring data using a USB flash drive 60 Creating a Task data folder on the USB flash drive 61 8 6 2 Transferring data via the FarmPilot portal 61 8 Step 2 Selecting a task to process 62 8 7 1 Creating a new task on the terminal 62 Creating a new task 62 Copyin
62. n be activated or deactivated For each machine the terminal calculates the length of time for which it was activated The icon preceding the name of the machine indicates whether the machine is activated or deactivated Copyright M ller Elektronik GmbH 8 Co KG 73 TaskManager application Step 4 Starting a task M LLER lektronik red background Machine is activated Pn Machine is deactivated green background no icon If you are processing the task using a machine not intended for this purpose no icon will appear before the machine s name Procedure 1 You can select a machine from a list as follows M You have started a task 1 Click on the following line on the Task data screen gt The following screen will appear Bo PIME ISO SPRAYER 02 03 2011 07 57 44 gt The screen contains a list of all machines which you have assigned to this task If you process the task using the assigned machine the machine displayed will be activated immediately If you are processing the task using a machine not assigned to this task no icon will appear before the machine s name gt Ifthe machine ME_ISO_Spritze appears at this point you have not created an ISO machine in your Farm Management Information System 6 2 LS Add machines gt A list of machines and farm equipment will appear a combine cultivator seeder tractor 1 tractor 2 akt combine 0x2000000000000000
63. n preceding the name of the task Tasks whose names are preceded by an asterisk are copies of other tasks The following table contains an overview of all icons used to mark the different types of tasks light yellow Tasks that have not been started yet A dark yellow Paused tasks 56 Copyright Muller Elektronik GmbH amp Co KG TaskManager application M LLER E lektronik Display layout in the TaskManager application a aaa Tasks processed by the Master Tasks that have not been started yet Tasks that have not been started yet and are tasks which are stored on the USB flash drive but have not yet been started These tasks may include Newly created tasks Copies of existing tasks if the name of the task is preceded by an asterisk Tasks imported via the FarmPilot portal or the Farm Management Information System which have not yet been started Paused tasks B Paused tasks are tasks which have been interrupted and not fully completed A task will be paused automatically if another task is started while the first task is still in progress Paused tasks are displayed in the FarmPilot portal as not yet completed Started tasks B Started tasks are tasks that have been started and are currently being processed Stopped tasks B Stopped tasks are tasks that have been stopped As a rule these are tasks which have been completed However the program is not capable of verifying whether the tasks h
64. nction icon Meaning Appears oniyits Delete file red Selected object can be deleted GPS Receiver is activated Configure GPS Receiver Configure FarmPilot FarmPilot portal is activated Open the Diagnostics screen Diagnostics is activated Retrieve default values Display DGPS connection status 7 2 Icons in the Service application You will find the following icons in the Service application cone d Function is activated Function is deactivated 7 3 Changing the language When you switch on the terminal for the first time the text may appear in a foreign language in German In this chapter you will learn how to change the language of the terminal Procedure q Switch on the terminal 2 Press 30 Copyright Muller Elektronik GmbH amp Co KG ki Configuring the terminal in the Service application M LLER kll lektronik Adjusting the brightness for day or night mode gt The following screen will appear Service k N 8x26 BxABRBLDBBACLABHAHF E ra N sS7h2de Om 8x87 8xA88C88888C 488884 TaskManager Sm OXF 8xNB9082000C 400AHF TRACK Leader Sm 8x1C 8x488817888C488A8F 3 i Click on Service gt Th D following screen will appear an Display settings File management X Driver settings MW Plugin settings 7A Licence management ME BASIC Terminal TOP 05 20 00
65. nment of ports A and B 86 9 4 3 Pin assignment of port C 87 9 4 4 Pin assignment of camera ports 1 and 2 88 10 Notes 90 6 Copyright M ller Elektronik GmbH 8 Co KG z For your safety MULLE lektronik Basic safety instructions 1 For your safety 1 1 Basic safety instructions Please read the following safety instructions carefully before using the equipment for the first time Before maintenance or repair to the tractor always disconnect the connection between the tractor and the terminal Before charging the tractor battery always disconnect the connection between the tractor and the terminal Before performing any welding operations on the tractor or a trailed machine always disconnect the power supply to the terminal Keep the terminal and its accessory components in good working order Do not make any unauthorised modifications to the equipment Unauthorised modifications or use may impair operability and or safety and reduce the service life of the unit Modifications are considered unauthorised if they are not described in the product documentation Never remove any safety mechanisms or signs from the machine Observe all applicable regulations on accident prevention Follow all recognised safety industrial and medical rules as well as all road traffic laws 1 2 Layout and meaning of warnings All safety instructions found in these Operating Instructions are composed in accordance with the following patte
66. ns that you do not understand please do not hesitate to contact us or your dealer Muller Elektronik s Customer Services department will be happy to assist you 1 4 Intended use BASIC Terminal TOP is intended exclusively for use in agriculture as well as in wine growing fruit cultivating and hop growing operations The manufacturer cannot be held responsible for any installation or use of the system that deviates from or exceeds the scope of intended use The manufacturer cannot be held liable for any personal injury or property damage resulting from such improper use All risks involved in engaging in improper usage lie solely with the user Intended use is also understood to include adherence to the conditions for operation and repair as prescribed by the manufacturer All applicable accident prevention regulations and all other generally recognised safety industrial and medical standards as well as all road traffic laws must be observed Any unauthorised modifications made to the equipment will void the manufacturer s warranty 1 5 EC declaration of conformity This product has been manufactured in conformity with the following national and harmonised standards as specified in the current EMC Directive 2004 108 EC EN ISO 14982 8 Copyright Muller Elektronik GmbH amp Co KG m About these Operating Instructions M LLER lektronik Target group of these Operating Instructions 2 About these Operating Instructions 2 1
67. of the worker indicates whether the worker is activated or deactivated Worker is deactivated red background Worker is activated green background Copyright M ller Elektronik GmbH amp Co KG 75 TaskManager application Step 4 Starting a task M LLER lektronik noicon No icon will precede the name of the worker assigned to the task Procedure 1 You can activate a worker as follows 1 Click on the following line on the Task data screen T gt The following screen will appear Worker 1 Dul joe toi 10001000 2 Select the name of an assigned or deactivated worker on the list 3 Press and hold for 3 seconds gt Worker will be activated Procedure 2 You can activate a worker who was not previously assigned to the task as follows 1 Click on the following line on the Task data screen gt The following screen will appear Worker 1 01 03 2011 00 00 00 The name ofthe assigned worker will appear on the screen However this worker has not vet been activated 2 Add worker gt A listofnames of available workers will appear 3 Click on the desired worker on the list 76 Copyright M ller Elektronik GmbH 8 Co KG TaskManager application MULLER lektronik Step 5 Using the TaskManager application during work gt The following screen will appear Worker 1 01 03 2011 00 00 00 OPOE AOIL Ova Steere The sele
68. oftware version can be found below the ME logo 9 4 Technical specifications 9 4 1 Technical specifications of the terminal Operating voltage 10 30 V Operating temperature 20 70 C Copyright M ller Elektronik GmbH 8 Co KG 85 Maintenance and servicing Technical specifications ME m rter In accordance with ISO 14982 PREN 55025 ESD protection In accordance with ISO 10605 Power input At terminal 30322921 Typically 0 4 A at 13 8 V without external eguipment At terminal 30322522 Typically 0 5 A at 13 8 V without external equipment Display VGA TFT colour display display size diagonal 14 5 cm resolution 640 x 480 pixels Boot USB 128 MB Internal clock Buffered by capacitor keeps the time for 2 weeks without an external power supply Keyboard 17 keys plus rotary knob Outputs 2 x CAN 1x USB 1x RS232 2 x M12 for two analogue cameras optional for item no 30322522 9 4 2 Pin assignment of ports A and B Ports A and B are both CAN interfaces Port B is not currently connected Pin assignment of the 9 pin D sub port of the ISO agricultural machinery interface CAN 86 Copyright Muller Elektronik GmbH amp Co KG u Maintenance and servicing M LLER Ba lektronik Technical specifications Pinno signa Pino sm 2o oe o e e so wow m je e 7 E ojee BEE EEE Vin voltage supply Vin ground The signals marked with correspond to the CIA assignment CAN in
69. omputer in which the so called machine geometry can be set up Therefore the position of the GPS Receiver in relation to the operating point must be entered Procedure Thus you can calculate the distances for all equipment without an ISOBUS jobcomputer 1 Measuring the distance between the operating point and the GPS Receiver e g from sprayer beam to GPS Receiver 2 Enter the distance measured as parameter Offset X 3 Measure the distance between the longitudinal axis of the machine and the GPS Receiver 4 Enter the distance measured as parameter Offset Y Copyright Muller Elektronik GmbH amp Co KG 21 Basic control principles a MULLE lektronik Getting to grips with the controls 5 Basic control principles 5 1 Getting to grips with the controls BASIC Terminal Terminal controls 1 Rotary knob 3 Keys 2 Function keys Controls Rotary knob The rotary knob is located in the top right hand corner of the terminal Control with the rotary knob may vary slightly between the different applications You can use the rotary knob to perform the following actions a 1 a Turning the rotary knob Move the cursor up and down Change a parameter value E 1 a Pressing the rotary knob Click on the selected line Activate parameter Confirm input Function keys Operating the function keys is the same across all applications E gt Performing the functions depicted on the display
70. on which will later be displayed in the header Selection The selected application is displayed in the header De Service 8x26 8xA88010888C 48808 sS7fh2de 0x87 8xAAAC8888AC 488884 TaskManager GxF7 8xA80082000C daa A AF Field Nav 0x10 8x448817888C daa A AF 4 ISO ID ofthe application ISO name of the application 5 Selection The selected application is displayed on the main display 6 Function icons on the right Open an application on the main display Cursor Open the selected application using the rotary knob Copyright M ller Elektronik GmbH amp Co KG ks Opening applications in the selection menu M LLE KAA lektronik Opening applications 6 2 Opening applications You can perform the following actions in the selection menu Open an application Display an application in the header of the split display Procedure PEET F Set which application is to be displayed in the header of the split display gt The function icon of the selected application is marked with a dot on the left hand side HH F o 2 Start the application for the main display There are several ways to do so With the rotary knob Select the desired application Open the selected application rn the function keys on the right hand side Display the application shown next to the function icon gt Both applications will appear on the display 6 3 Segmentation of t
71. only save the task if the function icon appears on the Task data screen Once saved the task data can no longer be altered Procedure M You have created a new task and entered the task data M You are on the following screen TSK 4 2011 02 24 07 44 25 kit Mueller SS 2 00 Field 2 ian Worker 4g 250 00 I ha AHL 28 Liter ie plant protection Vl 1 E Save task data This function icon will only appear if saving the task data is possible Copyright M ller Elektronik GmbH 8 Co KG 71 TaskManager application Memon J fr Step 4 Starting a task gt The following screen will appear E fertilization 2 00 Field 2 2011 02 24 07 44 25 2011 02 24 07 44 25 t Mueller SS 2 00 Field 2 tn Worker The saved task will appear on the Task list screen The name comprises the date and time the task was created gt You have saved the task New parameters will appear on the Task data screen Machine Worker You will only be able to alter these parameters once you start the task 8 9 Step 4 Starting a task You can start every task irrespective of its status Procedure 1 Switch to the Task list screen gt The following screen will appear E fertilization 2 00 Field 2 fertilization 2 00 Field 2 AA ee t Mueller SS 2 00 Field 2 Worker 2 Click on the desired task gt The following screen will appear 7 fertilization 2
72. product was manufactured for an The product may only be connected to agricultural machinery manufacturer the voltages within this range agricultural machinery manufacturer s item number will be shown here 2 Hardware version 5 Software version If you update the software this version will no longer be up to date 3 M ller Elektronik item number 6 Serial number Copyright M ller Elektronik GmbH 8 Co KG 11 Mounting and installation Instructions on retrofitting M LLER lektronik 4 Mounting and installation Mount the terminal and all additional components in the following order 1 BASIC Terminal TOP mount inside the tractor cab 2 Connect the terminal to the basic equipment 3 Connect the terminal to other components Refer to the following chapters to learn how to perform these steps 4 1 Instructions on retrofitting Instructions on how to retrofit electrical and electronic farm equipment and or components Agricultural equipment used today features electronic components and parts whose function can be affected by other farm equipment which emits electromagnetic waves Such effects could lead to personnel being put in danger if the following safety instructions are not adhered to Selecting components When selecting components make sure first of all that the retrofitted electrical and electronic components comply with the current version of the EMC Directive 2004 108 EC and carry the CE marking Us
73. r Configuring the GPRS connection manually gt 50 Server Server address The server address cannot be altered Log Switches logging on and off Switch on logging only when prompted to do so by Customer Services Procedure 1 Open the Service application Service 2 cs Open the access data screen for FarmPilot gt The following screen will appear a Username Den Password Y Provider Server fal Log ME TPD V02 02 02 TPI V02 02 00 48 Copyright M ller Elektronik GmbH 8 Co KG ki Configuring the terminal in the Service application M LLER wu lektronik Configuring FarmPilot 3 Click on the line with the desired parameter 4 Configure parameter 7 16 3 Entering data in the FarmPilot access data section Controls Below the characters you will find 5 icons which will assist you when entering the data Delete characters Move cursor to the left Move cursor to the right Confirm and finish input No function Seth Procedure 1 Switch to the FarmPilot access data screen Service gt The following screen will appear A KE f Password Y Provider Server fal Log ME TPD V02 02 02 TPI V02 02 00 2 Click on the selected line gt The following screen will appear BBCDEFGHIJKLMNOP ORSTUVWXYZabcdeig Hal Kal Ar eCa 4 4 OK 3 Enter the username Copyright M ller Elektronik GmbH amp Co KG 49 Configuring
74. rn This signal word identifies medium risk hazards which could potentially cause death or serious bodily injury if not avoided This signal word identifies low risk hazards which could potentially cause minor or moderate bodily injury or damage to property if not avoided This signal word identifies actions which could lead to operational malfunctions if performed incorrectly These actions require that you operate in a precise and cautious manner in order to produce optimum work results There are some actions that need to be performed in several steps If there is a risk involved in carrying out any of these steps a safety warning will appear in the instructions themselves Safety instructions always directly precede the step involving risk and can be identified by their bold font type and a signal word Example 1 NOTICE This is a notice It warns that there is a risk involved in the next step Copyright Muller Elektronik GmbH amp Co KG T For your safety M LLER lektronik User reguirements 2 Step involving risk 1 3 User reguirements Learn how to operate the terminal correctly The terminal must not be operated by anyone who has not read the Operating Instructions Please read and carefully observe all safety instructions and warnings contained in these Operating Instructions and in the manuals of any connected machines and farm eguipment f there is anything within these Operating Instructio
75. rs will appear gt Ifthe pool is empty nothing will appear 3 Click on the desired folder 36 Copyright Muller Elektronik GmbH amp Co KG ki Configuring the terminal in the Service application M LLER lektronik GPS Receiver gt The contents of the folder will be displayed un A i USB S Pools ke a00c80f80c400000 e SES6FEN iop 140 2KB e SIS6FEN iop 141 5KB e SIS6FDE iop 142 0KB 0 a00c80000c400457 The names of the folders are the ISO IDs of the applications whose temporary data they Store 4 Select the desired file A 5 Delete file gt Deleting file 6 Restart terminal 7 10 GPS Receiver When you connect a GPS Receiver to the terminal you must activate and configure it 7 10 1 Activating the GPS Receiver In order to activate the GPS Receiver you must first activate its driver A driver is a small program that controls connected farm equipment The drivers for the farm equipment supplied by M ller Elektronik are pre installed on the terminal Procedure 1 Switch to the Driver settings screen Service Driver settings gt The following screen will appear 5 k Diagnostics t FarmPilot LightBar t Camera 2 Select GPS 3 Click on GPS Copyright M ller Elektronik GmbH 8 Co KG 37 Configuring the terminal in the Service application GPS Receiver M LLER lektronik gt Theinstalled drivers will
76. rted Switch to the Task list screen if no task has been started Switch to the GPS Receiver offset screen Configure the position of the GPS Receiver Remove the USB flash drive Will only appear if the folder Task data exists on the USB flash drive Prepare an empty USB flash drive for use with the TaskManager application without FarmPilot The Task data folder will be created on the USB flash drive Download a set of tasks from the FarmPilot portal Will only appear if you are connected to the FarmPilot portal Upload set of tasks to the FarmPilot portal Will only appear if you are connected to the FarmPilot portal Display the field in FIELD Nav The function icon is grey when the function has been deactivated Create a new task Copy existing task Split stopped task Start task 53 TaskManager application M LLER lektronik Stop task Setting up the operation mode for the TaskManager application Confirm Save task data Select worker Deactivate worker Select machine Deactivate machine Start navigation to field The function icon is grey when the function has been deactivated Start navigation to unloading location Only appears if your terminal has the Slave status within a group of vehicles The function icon is grey when the function has been deactivated Enter filled capacity Enter emptied capacity 6 3
77. s all task data for the TaskManager application Procedure 1 Switch to the File management screen Service File management Copyright Muller Elektronik GmbH amp Co KG 35 Configuring the terminal in the Service application M LLER lektronik Deleting pools gt The following screen will appear isi kz Pools 2 Click on USB gt The Screencopy and Taskdata folders will appear gt f these folders fail to appear it is because you did not create them on the USB flash drive 3 Click on the desired folder gt The contents ofthe folder will be displayed A folder may either contain files or further folders If nothing is displayed the folder is empty 4 Selectthe files to be deleted E 5 Delete file red gt Deleting file 7 9 Deleting pools You can delete the pools to speed up the terminal s operation Pools are the intermediate storage for the terminal Pools are used to temporarily store graphics or text Over time the pools will become too large and slow down the operation of the terminal After updating the software of a connected jobcomputer f the terminal operates more slowly than usual When asked to do so by Customer Services When to delete Procedure 1 Switch to the File management screen Service File management gt The following screen will appear kz Pools 2 Click on Pools gt The names of several folde
78. ssed on this screen at gt 78 3 Task data section Counter section Contains detailed information about the Only appears when you start the task selected task The task data section may also contain the following icon This means that the task data also contain an application map The icon is used for information purposes only 8 5 Exporting machine settings for the Farm Management Information System In this chapter you will learn how to add a new machine to the master data and export it to the Farm Management Information System 58 Copyright Muller Elektronik GmbH amp Co KG TaskManager application M LLER oo lektronik Exporting machine settings for the Farm Management Information System When to perform You must perform this step in the following instances Before the first start up When connecting the terminal to a new machine When changing the machine parameters in the jobcomputer Method of function In this step all parameters of the ISO machine to which the terminal is connected are saved in an XML file During this step the ISO machine will be assigned a unique ID number which distinguishes it from other machines The unique ID number is also the serial number of the connected jobcomputer You can find it in the Selection menu application When you add a new machine to the master data with its unique ID number you will be able to export this ISO machine to the Farm Management Information Syste
79. t FarmPilot LightBar amp Camera 2 Click on Diagnostics 3 Click on the DiagnosticsServices driver gt Next to the driver the icon G will appear 4 Restart terminal 42 Copyright M ller Elektronik GmbH amp Co KG Configuring the terminal in the Service application M LLER u KA lektronik Activating the Diagnostics function gt The following function icon will appear on the start screen of the Service application gt You have activated the Diagnostics function 7 13 1 Jobcomputer diagnostics The screen Jobcomputer diagnosis contains a variety of information that is primarily important to Customer Services Customer Services can use this screen to determine which versions of the hardware and software are installed on your terminal This will speed up the diagnostic process if errors arise Sending diagnostic data to the portal Customer Services may ask you to send diagnostic data to the portal This allows Customer Services to gather detailed information about your terminal and therefore examine it more thoroughly Procedure M You have activated the Diagnostics function M You have activated the FarmPilot portal 1 Switch to the Jobcomputer diagnosis screen Service Jobcomputer Diagnostics i a E ieg Send diagnostic data gt The following notification will appear DeviceidentData transfer gt The data are being up
80. the USB flash drive is inserted into the terminal It will then replace the task data folder until the task data are written to the USB flash drive Thus until the A function key is pressed TaskData number Backup copies of the tasks sent to the FarmPilot portal will be created in this folder The folder will automatically be created on the USB flash drive when using the FarmPilot portal This reguires that the USB flash drive be inserted into the terminal Copyright M ller Elektronik GmbH 8 Co KG u Maintenance and servicing MULLER u lektronik Servicing and cleaning the terminal 9 Maintenance and servicing NOTICE This product does not contain any components which require maintenance or repair Never unscrew the casing 9 1 Servicing and cleaning the terminal Press the keys with your fingertips Avoid using your finger nails Only clean the product with a soft damp cloth Only use clear water or glass cleaner 9 2 Disposing of the unit When it has reached the end of its service life please dispose of this product as electronic scrap in accordance with all applicable EU waste management directives C 9 3 Checking the software version Procedure 1 Open the Service application Service 2 The following screen will appear 2 File management Driver settings M Plugin settings 7 Licence management ME BASIC Terminal TOP V 03 70 00 3 The s
81. ting and installation MULLE lektronik Mounting the terminal in the tractor cab 4 2 Mounting the terminal in the tractor cab Electromagnetic interference The operation of the terminal may be impaired by electromagnetic waves emitted by other farm equipment o Mount the terminal at least 1 m away from the radio antenna or from a radio device Procedure 1 Screw the bracket to the terminal 2 Mount the terminal with the bracket installed inside the tractor cab For instance you can use the ME base console for this purpose The base console is not included with the terminal This is included in the delivery content of the ISOBUS basic equipment gt 15 Base console 4 2 1 Screwing on the GSM antenna The GSM antenna transmits information to the FarmPilot portal via a mobile phone network Procedure 1 NOTICE There is a very sensitive contact pin in the centre of the GSM antenna Make sure not to damage the contact pin when screwing on the GSM antenna 2 Screw the GSM antenna onto the top of the terminal Copyright M ller Elektronik GmbH amp Co KG 13 Mounting and installation M MULLE lektronik Connecting the terminal to the basic eguipment 4 2 2 Terminal ports 14 _ _ 30322522 Reverse of the terminal BASIC Terminal TOP 1 GSM antenna port 6 USB port USB 1 1 2 Not currently in use 7 SIM card slot 3 Port for analogue camera Port B
82. to the basic equipment 14 4 3 1 Checking the ISOBUS compatibility of the basic equipment 15 4 3 2 Selecting the correct basic equipment 15 4 3 3 Connecting the terminal to the basic equipment 16 4 4 SIM card 16 44 1 Inserting the SIM card 16 4 5 GPS Receiver 18 4 5 1 Connecting the GPS Receiver to the terminal 19 4 5 2 Entering the position of the GPS Receiver 19 For machines fitted with an ISO jobcomputer 20 For machines not fitted with a jobcomputer 21 5 Basic control principles 22 5 1 Getting to grips with the controls 22 5 2 Using the function keys 23 9 3 Initial start up 24 9 4 Restarting the terminal 25 Copyright M ller Elektronik GmbH amp Co KG 3 Contents M LLER lektronik 6 Opening applications in the selection menu 26 6 1 Display layout in the selection menu 26 6 2 Opening applications 27 6 3 Segmentation of the display 27 7 Configuring the terminal in the Service application 29 7 1 Controls in the Service application 29 7 2 Icons in the Service application 30 7 3 Changing the language 30 7 4 Adjusting the brightness for day or night mode 31 15 Configuring the basic display settings 32 7 6 Activating and deactivating applications 33 7 7 Activating licences for full versions of the software 34 7 8 Deleting files from the USB flash drive 35 7 9 Deleting pools 36 7 10 GPS Receiver 3 7 10 1 Activating the GPS Receiver 37 7 10 2 Configuring the DGPS Receiver A100 38 7 11 Configuring the GPS TILT Module terrain co
83. which you can select and click on with the cursor You can use the input fields to specify which mix you wish to spread in what quantity and composed of what products The application will not check whether the quantities of the individual products total the rate for the mix The following picture shows an overview of the input fields Overview of the input fields 1 Rate 3 Unit of measure 2 Product guantity 4 Product type Procedure 1 Click on the following line 2 Click on the first field next to the icon sg 3 Enter the desired rate 4 Click on the middle field next to the icon sg 5 Select the unit of measure 70 Copyright Muller Elektronik GmbH amp Co KG TaskManager application MULLER lektronik Step 3 Entering and saving task data 6 Click on the right hand field next to the icon sg 7 Select the product type 8 Enter the product quantity and the unit of measure next to the icon amp gt Anew line containing the icon 5 will appear 9 You can enter additional products next to the icon 5 Ex 10 Confirm entries gt The data you entered will be saved gt The rate will appear on the Task data screen Measure Procedure 1 Click on the following line and hold for two seconds gt A listof available measures will appear 2 Select a measure gt The selected measure will appear on the Task data screen 8 8 2 Saving task data Gi You can
84. ws you to calculate the tasks more accurately The phase of task processing is visible on the Task data screen The following phases exist Driving time to field Preparation Working time Break Repair time Procedure 1 Click on the following line on the Task data screen TSK serial task number 3 D INSE E fertilization 2 00 Field 2 FA ae t Mueller SS 2 00 Field 2 skt ME_ISO_SPRAYER Volume counter 104 00 Surface counter 0 58 ha Distance counter 0 24 km Time counter 0 02 h gt The following screen will appear Preparation Working time Break Repairing time 2 Click on the desired phase of task processing gt The new phase is visible on the Task data screen 8 10 4 Evaluating counters When you start a task you can evaluate the counter while you are spreading your mix The counter will appear on the Task data screen 78 Copyright Muller Elektronik GmbH amp Co KG TaskManager application MULLER lektronik Step 5 Using the TaskManager application during work 8 10 5 Procedure 8 10 6 Example 1 Example 2 Controls Procedure IKSE fertilization 2 00 Field 2 FA En t Mueller 2 00 Field 2 skt ME ISO SPRAYER Volume counter 104 00 Surface counter 0 58 ha Distance counter 0 24 km Time counter 0 02 h Task data screen with counter The values gathered by the counter are up
Download Pdf Manuals