Home

1. Opening Code Operating Instructions for Multi

image

Contents

1. 1 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS Opening Code Operating Instructions for Multi Code LARK Lock Opening codes must first be enabled by a Master or Sub Master code Opening codes have ID numbers 01 through to 40 inclusive 1 1 1 1 1 1 2 1 2 1 1 2 2 1 2 3 To Open Lock Ensure the outer dial is fully to the left before starting Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice The display then shows time delay period If the display shows ATL CTNO or SCXX the time lock is on guard and the lock cannot be opened but if changing code or taking an audit wait for red LED to go out If the low battery LB is displayed for 4 seconds before the time delay value appears the lock will still operate correctly but the batteries should be changed as soon as possible Now enter code e g 1 2 3 4 5 6 your ID for example 07 followed by If the code is correct the countdown will commence down to 00 00 and OPEn will then be displayed The buzzer will sound and the green LED will flash While OPEn is displayed re enter code plus your ID and press If the correct code has been entered the screen will display and the green LED will remain on permanently The lock can then be opened for the next 6 seconds by turning the dial Keep hold of the dial with one hand and turn the safe handle with the other to op
2. 4 seconds before the time delay value appears the lock will still operate correctly but the batteries should be changed as soon as possible Put the jack plug of the audit storage module into the socket on the front of the keypad 5 4 1 Enter your 6 digit code plus your ID ILS 071 ISSUE 1 Page 7 of 10 14 May 1999 5 4 2 5 4 3 5 4 4 5 4 5 5 5 5 5 1 5 5 2 5 5 3 6 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS Press the printer key the screen will then show Audt for one second and then ConF Press the printer key again to confirm The screen then shows Aud and a segment of the last display sector will move around indicating that the information is being down loaded to the storage module On completion the screen will show and the buzzer will sound and the LED will flash Remove the audit storage module from the jack socket and take back to transfer audit to your computer See below Transferring Audit to your Computer Take the audit storage module and plug the jack into the socket in your computer lead Go to your LARK audit and programming software in your computer See separate instructions for installation into your computer Place the cursor over the box and click left mouse button After about 30 seconds you will see the full audit report on screen Master Code Operating Instructions The Lark comes with a factory set Master Code of 505050 50 Th
3. lock as in 1 1 1 1 4 2 Press the large padlock button top right of keypad The display shows Ctno for 1 second then Code 1 4 3 Enter current code plus your ID followed by The display shows ConF 1 4 4 Press the large padlock button again to confirm selection 1 4 5 The lock is now locked until the next pre programmed time opening For example 8 Oclock the following morning 1 5 Changing Batteries 1 5 1 Place your fingers gently on the battery holder and press down whilst using a small screwdriver to undo the top screw approximately 12 full turns 1 5 2 Pull the battery holder up using the finger grips 1 5 3 Change batteries using only DURACELL TYPE AA MN 1500 batteries making sure to insert the correct way round as marked in the holder 1 5 4 Re fit holder hold down firmly and re tighten the screw Do not over tighten the screw ILS 071 ISSUE 1 Page 2 of 10 14 May 1999 2 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS Audit Code Operating Instructions Audit codes are on default 48484848 amp 49494949 Audit codes can only take an Audit and change their code They are ID codes 48 and 49 THEY CANNOT OPEN THE LOCK 2 1 2 1 1 2 2 2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 To Take an Audit Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice The display then shows time delay period If the displa
4. via your computer See separate programming and audit software instructions insert the jack plug into the socket on the front of the keypad 6 3 2 Wake up the lock as in 5 1 1 above Enter your current Master code plus ID followed by O The screen will then display your ID E E is for enter e g 50E and the red LED will be on 6 3 3 Press O square again and the screen will show Id__ 6 3 4 Press O square again and the screen will show UpdP for up date program 6 3 5 Press screen shows UPOP for confirm Then press O square again Screen will show CPYP for copying program for approximately 10 seconds ILS 071 ISSUE 1 Page 9 of 10 14 May 1999 6 3 6 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS On completion the screen will show and the buzzer will sound and the LED will flash NOTE We recommend that an audit is taken to confirm that the new program is as you wanted 6 4 Taking an Audit 6 4 1 Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice The display then shows time delay period 6 4 2 Ifthe display shows ATL CTNO or SCXX the time lock is on guard and the lock cannot be opened but if changing code or taking an audit wait for red LED to go out 6 4 3 If the low battery LB is displayed for 4 seconds before the time delay value appears the lock will still operate correctly but the batteries sho
5. E 1 Page 5 of 10 14 May 1999 5 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS Sub Master Code Operating Instructions Sub Master code must first be enabled by a Master Code These codes have ID numbers 42 through to 47 inclusive They can change Opening Audit Engineering cash carry codes and take an audit They can also transfer a new time locking program from the programming module THEY CANNOT OPEN THE LOCK 5 1 5 1 1 5 1 2 5 1 4 5 2 5 2 1 5 2 2 5 2 3 5 2 4 5 2 5 Changing your Sub Master Code Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice The display then shows time delay period If the display shows ATL CTNO or SCXxX the time lock is on guard and the lock cannot be opened but if changing code or taking an audit wait for red LED to go out If the low battery LB is displayed for 4 seconds before the time delay value appears the lock will still operate correctly but the batteries should be changed as soon as possible Enter your Sub Master code plus ID followed by O The screen will then display your ID E E is for enter e g 42E and the red LED will be on Enter new code e g 1 2 3 4 5 6 plus your ID followed by The screen then changes to ID C 42C for example C is for confirm the green LED also comes on Enter new code again plus your ID followed by After 1 2 seconds the buzze
6. dicates that the new code has been accepted 6 2 Changing Enabling Disabling a Sub Master Opening Engineering cash carry or Audit Code 6 2 1 Wake up the lock as in 5 1 1 above Enter your Master code plus ID followed by 0 The screen will then display your ID E E is for enter e g 50E and the red LED will be on 6 2 2 Press the square again and the screen will show Id__ 6 2 3 Enter the ID of the code you wish to change or enable disable Remember the Engineering code is 00 the Opening codes are 01 through to 40 the cash carry code is 4 the sub Master codes are 42 through to 47 and the Audit codes are 48 and 49 To up load from the module press PRINTER to confirm then the square 6 2 4 Press the and the screen will show the ID number and E for enter For example 07E Y Y for enable of N for not enabled 6 2 5 Enter new code e g 1 2 3 4 5 6 plus the ID followed by The screen then changes to ID C for example 07C C is for confirm and the green LED also comes on NOTE Setting 000000 plus the ID disables that code 6 2 6 Enter new code again plus the ID followed by After 1 2 seconds the buzzer will sound several times the screen will show and both LED s will flash This indicates that the new code has been accepted 6 3 To Down Load a New Time Lock Weekly Program NOTE You cannot do this if the time lock is already on guard 6 3 1 With your programming module programmed
7. e last two digits being the code ID 50 You must change this code as soon as possible keeping the last 2 digits as your ID The Master code can enable disable and change Opening Sub Master Audit cash carry and Engineering codes It can also take an audit and down load a new time lock program IT CANNOT OPEN THE LOCK 6 1 6 1 1 6 1 2 Changing Your Master Code Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice The display then shows time delay period If the display shows ATL CTNO or SCXxX the time lock is on guard and the lock cannot be opened but if changing code or taking an audit wait for red LED to go out If the low battery LB is displayed for 4 seconds before the time delay value appears the lock will still operate correctly but the batteries should be changed as soon as possible Enter your Master code plus ID followed by O The screen will then display your ID E E is for enter e g 50E and the red LED will be on Enter new code e g 1 2 3 4 5 6 plus your ID followed by The screen then changes to 50C C is for confirm and the green LED also comes on ILS 071 ISSUE 1 Page 8 of 10 14 May 1999 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS 6 1 4 Enter new code again plus your ID followed by After 1 2 seconds the buzzer will sound several times the screen will show and both LED s will flash This in
8. en return to Id__ To continue enter next ID To escape press 5 3 To Down Load a New Time Lock Weekly Program NOTE You cannot do this if the time lock is already on guard 5 3 1 With your programming module programmed via your computer See separate programming and audit software instructions insert the jack plug into the socket on the front of the keypad 5 3 2 Wake up the lock as in 4 1 1 above Enter your current Sub Master code plus ID followed by O The screen will then display your ID E E is for enter e g 41E and the red LED will be on 5 3 3 Press O square again and the screen will show Id__ 5 3 4 Press O square again and the screen will show UpdP for up date program 5 3 5 Press screen shows UPCP for confirm Then press O square again Screen will show CPYP for copying program for approximately 10 seconds 5 3 6 On completion the screen will show and the buzzer will sound and the LED will flash NOTE We recommend that an audit is taken to confirm that the new program is as you wanted 5 4 Taking an Audit 5 4 1 Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice The display then shows time delay period If the display shows ATL CTNO or SCXxX the time lock is on guard and the lock cannot be opened but if changing code or taking an audit wait for red LED to go out If the low battery LB is displayed for
9. en the safe door NOTE If at any time you wish to cancel the countdown press the key Changing the Opening Code Wake up the lock as in 1 1 1 above Enter your current opening code plus ID followed by O The screen will then display your ID E E is for enter e g 07E and the red LED will be on Enter new code e g 1 2 3 4 5 6 plus your ID followed by The screen then changes to ID C for example 07C C is for confirm and the green LED also comes on Enter new code again plus your ID followed by After 1 2 seconds the buzzer will sound several times the screen will show and both LED s will flash This indicates that the new code has been accepted ILS 071 ISSUE 1 Page 1 of 10 14 May 1999 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS 1 3 Short Close 1 3 1 Wake up lock as in 1 1 1 1 3 2 Press small padlock button top left of Keypad Display shows SC XX where XX is the short close period in minutes 1 3 3 Press to accept this function Display shows Code 1 3 4 Enter current code plus your ID followed by The display shows ConF 1 3 5 Press small padlock button again to confirm short close required 1 3 6 The display will then show SC and the time period left before the lock can once again be opened The display will then go blank On pressing the the screen will show the current time remaining after the SC 1 4 Close Till Next Open Ctno 1 4 1 Wake up the
10. r will sound several times the screen will show and both LED s will flash This indicates that the new code has been accepted Enabling Disabling or Changing an Opening Audit cash carry or Engineering Code Wake up the lock as in 4 1 1 above Enter your Sub Master code plus ID followed by The screen will then display your ID E E is for enter e g 42E and the red LED will be on Press the O square again and the screen will show Id__ Enter the ID of the code you wish to change or enable disable Remember the Engineering code is 00 the Opening codes are 01 through to 40 code 41 is the cash carry code and the Audit codes are 48 and 49 To upload from code module press PRINTER then the square Press the and the screen will show the ID number and E for enter For example 07E Y Y for enable of N for not enabled Enter new code e g 1 2 3 4 5 6 plus the ID followed by The screen then changes to ID C for example 07C C is for confirm and the green LED also comes on NOTE Setting 000000 plus the ID disables that code ILS 071 ISSUE 1 Page 6 of 10 14 May 1999 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS 5 2 6 Enter new code again plus the ID followed by After 1 2 seconds the buzzer will sound several times the screen will show and both LED s will flash This indicates that the new code has been accepted NOTE The screen will th
11. reen displays ILS red and green LED s light and buzzer sounds twice The display then shows time delay period If the display shows ATL CTNO or SCXxX the time lock is on guard and the lock cannot be opened but if changing code or taking an audit wait for red LED to go out If the low battery LB is displayed for 4 seconds before the time delay value appears the lock will still operate correctly but the batteries should be changed as soon as possible 4 1 2 Now enter code e g 1 2 3 4 5 6 your ID 41 followed by 4 1 3 If the correct code has been entered the screen will display and the green LED will remain on permanently The lock can then be opened for the next 6 seconds by turning the dial Keep hold of the dial with one hand and turn the safe handle with the other to open the safe door 4 2 Changing the cash carry Code 4 2 1 Wake up the lock as in 4 1 1 above Enter your current opening code plus ID 41 followed by O The screen will then display your 41 E E is for enter and the red LED will be on 4 2 2 Enter new code e g 1 2 3 4 5 6 plus your ID 41 followed by The screen then changes to 41 C C is for confirm and the green LED also comes on 4 2 3 Enter new code again plus your ID 41 followed by After 1 2 seconds the buzzer will sound several times the screen will show and both LED s will flash This indicates that the new code has been accepted ILS 071 ISSU
12. s will flash This indicates that the new code has been accepted ILS 071 ISSUE 1 Page 3 of 10 14 May 1999 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS 2 3 Transferring Audit to your Computer 2 3 1 Take the audit storage module and plug the jack into the socket in your computer lead 2 3 2 Go to your LARK audit and programming software in your computer See separate instructions for installation into your computer 2 3 3 Place the cursor over the box and click left mouse button After about 30 seconds you will see the full audit report on screen 3 Engineering Code This has 3 Safeguards 1 It can not open the lock on its own 2 It has to be enabled by a Master or Sub Master code 3 It has to have an opening code entered before it is used It is to open in engineering hours when ATL is displayed if required 3 1 1 Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice The screen shows ATL for Automatic Time Lock Wait for the red LED to go out 3 1 2 Enter a valid opening code plus ID and press the 3 1 3 Enter within 10 seconds the Engineering code plus 00 ID and the 3 1 4 If the code is correct the countdown will commence down to 00 00 and OPEn will then be displayed The buzzer will sound and the green LED will flash 3 1 5 While OPEn is displayed re enter Engineering code plus 00 and press If the correct code has been en
13. tered the screen will display and the green LED will remain on permanently The lock can then be opened for the next 6 seconds by turning the dial Keep hold of the dial with one hand and turn the safe handle with the other to open the safe door NOTE If at any time you wish to cancel the countdown press the key 3 2 Changing Engineering Code 3 2 1 Press until screen shows ILS Screen displays ILS red and green LED s light and buzzer sounds twice 3 2 2 Enter your existing code followed by your ID 00 3 2 3 Press the O square The screen will show your IDE eg 00E and the red LED will be on E is for enter ILS O71 ISSUE 1 Page 4 of 10 14 May 1999 INTELLIGENT LOCKING ILS FULL INSTRUCTIONS FOR MULTI CODE LOCK CC SYSTEMS 3 2 1 Enter a new 6 digit code plus your ID then 3 2 5 The screen will now show your IDC e g 00C C is for confirm so re enter your new code plus your ID then After 1 2 seconds the buzzer will sound several times the screen will show and both LED s will flash This indicates that the new code has been accepted 4 Cash carry Code Operating Instructions The cash carry code must first be enabled by a Master or Sub Master code The code has the ID numbers 41 The cash carry code can over ride the time delay but not the time lock 4 1 To Open Lock Ensure the outer dial is fully to the left before starting 4 1 1 Press until screen shows ILS Sc
14. uld be changed as soon as possible 6 4 4 Put the jack plug of the audit storage module into the socket on the front of the keypad 6 4 5 Enter your 6 digit code plus your ID 6 4 6 Press the printer key the screen will then show Audt for one second and then ConF 6 4 7 Press the printer key again to confirm The screen then shows Aud and a segment of the last display sector will move around indicating that the information is being down loaded to the storage module 6 4 8 On completion the screen will show and the buzzer will sound and the LED will flash 6 4 9 Remove the audit storage module from the jack socket and take back to transfer audit to your computer See below 6 5 Transferring Audit to your Computer 6 5 1 Take the audit storage module and plug the jack into the socket in your computer lead 6 5 2 Go to your LARK audit and programming software in your computer See separate instructions for installation into your computer 6 5 3 Place the cursor over the box and click left mouse button After about 30 seconds you will see the full audit report on screen ILS 071 ISSUE 1 Page 10 of 10 14 May 1999
15. y shows ATL CTNO or SCXxX the time lock is on guard and the lock cannot be opened but if changing code or taking an audit wait for red LED to go out If the low battery LB is displayed for 4 seconds before the time delay value appears the lock will still operate correctly but the batteries should be changed as soon as possible Put the jack plug of the audit storage module into the socket on the front of the keypad Enter your 6 digit code plus your ID 48 or 49 Press the printer key the screen will then show Audt for one second and then ConF Press the printer key again to confirm The screen then shows Aud and a segment of the last display sector will move around indicating that the information is being down loaded to the storage module On completion the screen will show and the buzzer will sound and the LED will flash Remove the audit storage module from the jack socket and take back to transfer audit to your computer See below Changing your Audit Code Wake up the lock as in 2 1 1 Enter your existing code followed by your ID 48 or 49 Press the O square The screen will show your IDE e g 48E and the red LED will be on E is for enter Enter a new 6 digit code plus your ID then The screen will now show your IDC e g 48C C is for confirm so re enter your new code plus your ID then After 1 2 seconds the buzzer will sound several times the screen will show and both LED