1. Mobile air conditioner unit HCL147 Operating Instructions The HCL 147E is a powerful split system portable air conditioner unit designed for comfort cooling generating 14 000BTU HR or 4 1kw of cooling This mobile air conditioner unit is suitable for comfort cooling offices portacabins commercial premises exhibitions and computer sites Easy air conditioning installation it requires a 13 amp socket Other features on this mobile air conditioner unit include e Thermostat control e High low fan speed e Electric Heater e 24 hour timer e Additional 3 metre refrigerant line allowing up to a 6 metre line e Quick connect couplings e Easy clean filters Air conditioner Installation For the best comfort cooling ideally position the mobile air conditioner condenser unit through a window supplied with hanging straps and hooks it can also be installed through a hole in a wall The clips must face towards the wall so the hot air flow is directed towards the outside Please ensure that the outside condenser of the portable air conditioner unit is fastened securely e Temporary mobile air conditioner installation The refrigerant line connecting the indoor part of the portable air conditioner unit to the external condenser can be placed through an open window The window sections should then ideally be closed as much as possible and sealed e When moving the mobile air conditioner hook the two units together with the built in clips
2. e Before bringing the outside unit in tilt it to empty any water inside e Permanent mobile air conditioner unit Installation To be able to shut the window completely cut a 45 x 25mm slot in the window e Ensure the refrigerant line connecting the indoor part of the portable air conditioner to the external condenser is not twisted e At the end of the season before storing the mobile unit drain the condensate tank by removing its cap Don t forget to replace the cap afterwards e Permanent mobile air conditioner installation must be carried out by a qualified person Contact London Cool on 0800 440 444 Hang condenser out through Windows upped with hanging Stranos and hooks or drill hole through wall tee boloa CeO ae ae 10 Timer setting control 11 Timer functioning indicator light On Off switch Fan speed selector switch Air conditioner unit tank full indicator light Thermostat Power ON indicator light Cooling Heating switch Heater status indicator light Air conditioner status indicator light Timer Cooling Turn the thermostat knob 4 all the way towards right max cooling Press the on switch Make sure the heating switch 6 has not been pressed and then set the fan speed 2 When the desired comfort level has been reached turn the thermostat knob 4 towards left until the compressor switches off Your mobile air conditioner will now automatically maintain the comfort level you have set To turn
3. off and on again use the ON OFF switch 1 Adjust the airflow louver in your preferred position Heating Press the ON switch 1 Move the thermostat knob 4 to the red section of the control panel all the way towards left Press the heating switch 6 When the desired comfort cooling level has been reached turn the thermostat knob 4 to the right until the status light above the button switches off The windows must be completely shut when the heating function is in use Check the position of the timer switch to make sure it has not been turned on Turn the timer knob 9 in order to set the control on present time Pull the clips for the time the air conditioner is to run Example Timer set at 12 00 o clock The air conditioner is to run from 3 00 5 00 pm Press the timer switch 10 Trouble Shooting HCL147E Split Air Conditioning Unit PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION The air conditioner does not turn on Not plugged in Plug in or check if the socket is live Portable air conditioner unit does not cool Thermostat is not set correctly on blue Set thermostat zone Cooling ON button is not pressed in Push in cooling button Check to be certain key 6 has not been pressed OF Air filters are clogged Clean air filters Air conditioner does not cool the room Excessive thermal load Try air conditioner in a smaller room with less exposure to the sun aS Windows and doors are open too much Close them as much as
4. possible Control panel is ON but the room air Water condensate tank is full Empty the water tank conditioner does not perform any function If none of the suggested solutions apply please switch the unit off unplug it and call London Cool for service on 0800 440 444 London Cool air conditioner rental amp Sales This document has been compiled in good faith but no representation is made or warranty given either express or implied as to the completeness or accuracy of this information

Download Pdf Manuals

image

Related Search

Related Contents

  Frigidaire FFRE0633Q1 Energy Guide : Free Download, Borrow, and Streaming : Internet Archive  R 55(C) R 99(C)  Appliance Manual  238 - Austromex  TS 55 EBQ TS 55 EQ TS 55 Q  Marmitek EasyTouch35  Didacticiel BEV      

Copyright © All rights reserved.
Failed to retrieve file