Home

Bedienungsanleitung de Operating instructions en Mode d

image

Contents

1. Serial no 2 Description 2 1 Use of the product as directed The Hilti PS 30 Ferrodetector is designed to detect ferrous metals steel rebars and non ferrous metals copper and aluminium The tool is not suitable for locating tensioning cables The tool and its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used not as directed Observe the information printed in the operating instructions concerning operation care and maintenance Take the influences of the surrounding area into account Do not use the tool or appliance where there is a risk of fire or explosion Modification of the tool is not permissible 2 2 Display The settings and tool status are shown in the display 2 3 Display illumination The display illumination switches on automatically in conditions of low ambient light 2 4 Display Areas of the display Status area Detection area Shows the two areas of the display 2 5 Status indicator Status area x E Ferrous metal object Non ferrous metal object Audible signal off OIOI Battery status Shows which status is active 2 6 Symbols in the display Audible signal active left 4 igh 9X 11 2 7 Warnings and error symbols in the display Error message Temperature warning eL Electromagnetic interference gt Calibration warning gt Contact Hilti s
2. end of their life must be collected separately and returned to an environmentally compatible recycling facility 11 Manufacturer s warranty Hilti warrants that the tool supplied is free of defects in material and workmanship This warranty is valid so long as the tool is operated and handled correctly cleaned and serviced properly and in accordance with the Hilti Operating Instructions and the technical system is main tained This means that only original Hilti consumables components and spare parts may be used in the tool This warranty provides the free of charge repair or re placement of defective parts only over the entire lifespan of the tool Parts requiring repair or replacement as a result of normal wear and tear are not covered by this warranty Additional claims are excluded unless stringent na tional rules prohibit such exclusion In particular Hilti is not obligated for direct indirect incidental or con sequential damages losses or expenses in connec tion with or by reason of the use of or inability to use the tool for any purpose Implied warranties of merchantability or fitness for a particular purpose are specifically excluded For repair or replacement send the tool or related parts immediately upon discovery of the defect to the address of the local Hilti marketing organization provided This constitutes Hilti s entire obligation with regard to warranty and supersedes all prior or contemporaneous c
3. tool Check that the tool makes full contact with the surface you wish to scan Use the tool only on smooth surfaces Bring the tool slowly and carefully into contact with the surface to be scanned Do not move the tool at a speed greater than 20 cm s 9 in s 6 2 1 Sweep scan method In order to achieve best results the tool should be used with a sweeping motion extended horizontal and vertical back and forward movements over the object The series of illustrations shows the sweep scan technique in use Switch the tool on and hold it at least 30 cm 12 in away from any metal objects and away from the surface on which you are working 2 Carefully bring the tool into contact with the surface to be scanned and then begin to move it sideways When the tool approaches a ferrous metal object a rebar the ferrous metal symbol begins to blink the status LEDs light red and the amplitude of the signal strength indicator rises and reaches its max imum when the tool is positioned over the center of the object If the tool is moved further until it is past the ferrous metal the status LEDs light green and the signal strength indicator shows a decreasing value To obtain an exact indication of the position of the rebar the tool must be moved back in the opposite direction until the status LEDs again light red and the signal strength indicator shows the max imum value Use the ma
4. 20 C 10h Operating temperature range 15 50 5 F to 122 F Automatic cut out 5 min Storage temperature range dry 25 63 C 13 to 145 F Relative air humidity 9596 Protection class IP 54 protection against dust and water spray Weight including batteries 420 g 0 99 Ib Dimensions L x W x H 237 mm x 104 mm x 47 mm 9 4 in x 4 in x 2 in 4 Safety instructions In addition to the information relevant to safety given in each of the sections of these operating instructions the following points must be strictly observed at all times The tool is designed to detect ferrous metals steel rebars and non ferrous metals copper aluminium in concrete brick drywall and under plaster surfaces in accordance with the information provided in the technical data section 4 1 Basic information concerning safety a Do not render safety devices ineffective and do not remove information and warning notices b Keep children away from the tool Check that the tool functions correctly each time before use d Checkthe display after switching the tool on The display should show all symbols within 1 second Check to ensure that the tool is able to calibrate itself after switching on f Operation of the tool in the proximity of pregnant women is not permissible 9g Rapidly changing detection conditions may lead to inaccurate readings h Usethe tool only within its specified limits
5. Do not use the tool on materials containing tensioning cables or stainless steel objects ij Do not use the tool in the proximity of medical instruments and appliances j Do not drill at positions where the tool has located an object k The warnings shown in the display must always be observed Do not use the tool in the proximity of electro magnetic interference e g electric breakers in operation Take the influences of the surrounding area into account Do not use the tool where there is a risk of fire or explosion i n Make sure that the display area can be easily read e g do not touch the display area with the fingers keep the display area clean o Do not use the tool if it is defective p Always keep the detection area clean q The accuracy of the tool is influenced by the base material If the tool is unable to calibrate itself cor rectly scanning errors may result r When the tool is unable to calibrate itself automatic ally a warning appears in the display S Use ofthe tool in the proximity of persons with a cardiac pacemaker is not permissible 4 2 Proper organization of the workplace Avoid unfavorable body positions when working on ladders or scaffolding Make sure you work from a safe stance and stay in balance at all times b Whenthe tool is brought into a warm environment from very cold conditions or vice versa allow it to become acclimatized before use Use the tool only
6. eile PS 30 Bedienungsanleitung Operating instructions Mode d emploi Istruzioni d uso Manual de instrucciones Manual de instru es Gebruiksaanwijzing Brugsanvisning Bruksanvisning Bruksanvisning Kayttoohje xanosuc Hasznalati utasitas Instrukeja obstugi N vod k obsluze N vod na obsluhu Upute za uporabu Navodila za uporabo Instructiuni de utilizare Kulllanma Talimat Lieto anas pam c ba Instrukcija Kasutusjuhend 3 te R HE RPA Printed 07 07 2013 Doc Nr PUB 5137821 000 00 ORIGINAL OPERATING INSTRUCTIONS PS 30 ferrodetector It is essential that the operating instructions are read before the tool is operated for the first time Always keep these operating instructions to gether with the tool Ensure that the operating instructions are with the tool when it is given to other persons Contents Page 1 General information 10 2 Description 11 3 Technical data 12 4 Safety instructions 13 5 Before use 14 6 Operation 15 7 Care and maintenance 16 8 Troubleshooting 16 9 FCC statement applicable in US ICES statement applicable in Canada 17 10 Disposal 17 11 Manufacturer s warranty 17 12 EC declaration of conformit
7. erature limits for storage of your equipment must be observed especially in winter summer 7 2 Storage Remove the tool from its case if it has become wet The tool its carrying case and accessories should be cleaned and dried at maximum 40 C 104 F Repack the equipment only once it is completely dry Check the accuracy of the equipment before it is used after a long period of storage or transportation Remove the batteries from the tool before storing it for a long period Leaking batteries may damage the tool 7 3 Transport Use the Hilti toolbox or packaging of equivalent quality for transporting or shipping your equipment Store the tool safely CAUTION Always remove the batteries before shipping the tool 7 4 Hilti calibration service We recommend that the tool is checked by the Hilti cal ibration service at regular intervals in order to verify its reliability in accordance with standards and legal require ments Use can be made of the Hilti calibration service at any time but checking at least once a year is recommended The calibration service provides confirmation that the tool is in conformance on the day it is tested with the specifications given in the operating instructions The tool will be readjusted if deviations from the man ufacturer s specification are found After checking and adjustment a calibration sticker applied to the tool and a calibration certificate provide written verification that the t
8. ervice Inadmissible operating range Too much interference from the surroundings Calibration is required 2 8 Battery condition indicator Number of segments shown 3 2 1 0 Battery symbol blinks 2 9 Items supplied Tool Hand strap Soft pouch Operating instructions Batteries PO BR aA a a a a Markers Manufacturer s certificate Charge status in 100 capacity 80 capacity 50 capacity 20 capacity fully discharged 3 Technical data Right of technical changes reserved NOTE All values apply to individual rod like metal objects positioned at right angles to the direction of movement of the detector and when the surface of the concrete is flat and smooth with no external interference factors Detection range and accuracy is reduced when measurements are taken on brickwork PS 30 Detection range for locating ferrous metals gt 8mm 3 5 120 mm 74 4 in 2 6 8 mm 5 100 mm 74 in 4 in Detection range for locating non ferrous metals copper Diameter at least 10 mm 7 in Pipe wall thickness at and aluminium pipes least 2 mm 3 2 in 5 80 mm 3 s in Localization accuracy 10 mm x in Minimum distance between objects Depth range 5 55 mm 21 s 55 mm 2 s in Depth range gt 55 mm 21 in Distance depth factor 21 5 Power source 4x1 5V AAA LROS alkaline batteries Battery life at
9. itions 1 This device may not cause interference not in compli ance with the standards 2 This device must accept any interference received in cluding interference that may cause undesired operation NOTE Changes or modifications not expressly approved by Hilti could void the user s authority to operate the equipment PS 30 01 Hilti trademark of Hilti Corp Schaan LI Made in Malaysia This device complies with part 15 of the FCC Rules Operation is subject to the condition that this device does not Te Gass ns D oka ees complies wih Canadian IGES O08 Get apparel num rique dela casse B ct conforme la norme NMB 0S du Canad Power 6V 140 mA 4025 FE G ALR o 8 Item No Serialnumber 10 Disposal EO Most of the materials from which Hilti tools or appliances are manufactured can be recycled The materials must be correctly separated before they can be recycled In many countries Hilti has already made arrangements for taking back old tools or appliances for recycling Ask Hilti Customer Service or your Hilti representative for further information For EC countries only Do not dispose of electronic measuring tools or appliances together with household waste In observance of the European Directive on waste electrical and electronic equipment and its imple mentation in accordance with national law electric tools and batteries that have reached the
10. ol before using it for detection or measurement 4 5 Electrical safety b Keep the batteries out of reach of children Do not allow the batteries to overheat and do not expose them to fire The batteries may explode or release toxic substances Do not charge the batteries Do not solder the batteries into the tool Do not discharge the batteries by short circuiting This may cause them to overheat and present a risk of personal injury burns Do not attempt to open the batteries and do not subject them to excessive mechanical stress 4 6 Transport Always remove the batteries before shipping the tool 5 2 Checking the tool 5 1 Inserting the batteries El CAUTION Do not use damaged batteries CAUTION Always replace the complete set of batteries DANGER Do not mix old and new batteries Do not mix batteries of different makes or types 1 14 Open the battery compartment Remove the batteries from the packaging and insert them in the tool NOTE Take care to observe correct polarity see symbols in battery compartment Check to ensure that the battery compartment cover is closed correctly 1 2 Check to ensure that the sensor area is not damp If necessary use a cloth to dry the sensor area For accurate results allow the tool to acclimatize itself to the ambient conditions before switching it on if it has previously been exposed to extreme temperature fluctuations 5 3 Switching the
11. omments and oral or written agreements concerning warranties 12 EC declaration of conformity original Designation Ferrodetector Type PS 30 Year of design 2009 We declare on our sole responsibility that this product complies with the following directives and standards 2011 65 EU 2006 95 EC 2004 108 EC EN ISO 12100 Hilti Corporation Feldkircherstrasse 100 FL 9494 Schaan JL mE Paolo Luccini Head of BA Quality and Process Man agement Business Area Electric Tools amp Ac cessories 01 2012 Matthias Gillner Executive Vice President Business Area Electric Tools amp Accessories 01 2012 Technical documentation filed at Hilti Entwicklungsgesellschaft mbH Zulassung Elektrowerkzeuge Hiltistrasse 6 86916 Kaufering Deutschland ml m m Hilti Corporation 11 9494 Schaan Tel 4423 23421 11 Fax 4423 23429 65 www hilti com Hilti registered trademark of Hilti Corp Schaan W 3654 0313 10 Pos 1 1 Printed in Germany 2013 Right of technical and programme changes reserved S amp 404004
12. ool operates in accordance with the manufacturer s Specification Calibration certificates are always required by companies certified according to ISO 900x Your local Hilti Center or representative will be pleased to provide further information 8 Troubleshooting Fault Possible cause Remedy The tool can t be switched on The battery is exhausted Replace the battery The battery is inserted the wrong way Insert the battery correctly round incorrect polarity The battery compartment is not closed Close the battery compartment The tool can t calibrate itself gt The tool is too close to metal objects Switch the tool off and then hold it at least 30 cm 12 in away from any metal objects and away from the sur face on which you are working before switching it on again The tool displays an electro magnetic interference warning gt The tool is too close to a source of electromagnetic interference Keep the tool away from electromag netic interference The tool displays a temperature warning low eL The temperature is too high or too Observe the operating temperature range technical data 9 FCC statement applicable in US ICES statement applicable in Canada This device complies with section 15 of the FCC stand ards and fulfills the 1 requirements in accordance with ICES 008 for class B Operation is subject to the following two cond
13. rking pen supplied to mark the position of the ferrous metal object through the marking opening in the tool If the loudspeaker has been activated a constant audible signal is emitted so long as the tool is positioned over the ferrous metal object When the tool approaches a non ferrous metal ob ject copper aluminium the non ferrous metal symbol begins to blink the status LEDs light red and the amplitude of the signal strength indicator rises and reaches its maximum when the tool is po sitioned over the center of the object If the tool is moved further until it is past the non ferrous metal object the status LEDs light green and the signal strength indicator shows a decreasing value To ob tain an exact indication of the position of the rebar the tool must be moved back in the opposite dir ection until the status LEDs again light red and the signal strength indicator shows the maximum value Use the marking pen supplied to mark the position of the non ferrous metal object through the marking opening in the tool If the loudspeaker has been ac tivated a constant audible signal is emitted so long as the tool is positioned over the non ferrous metal object 15 EI 7 Care and maintenance 7 1 Cleaning and drying 1 Use only a clean soft cloth for cleaning If necessary moisten the cloth slightly with pure alcohol or a little water NOTE Do not use any other liquids as these may damage the plastic components The temp
14. tool on off 1 2 Switch the tool on by pressing the on off button When the tool is already switched on press the on off button The tool switches off NOTE f the tool is not used or an error message is displayed it switches itself off automatically after five minutes The tool switches itself off when the batteries are discharged 5 4 Switching the audible signal on off 1 Press the on off button for 5 seconds The audible signal menu is displayed If the audible signal is already activated it can be deactivated by pressing the on off button again To switch the tool off press the on off button for 5 seconds Switch the tool on The new settings are shown in the display and the tool is ready for use 6 Operation 6 3 Locating objects 6 1 Preparing the tool for use CAUTION Always drill at a safe distance from objects you have detected 1 Before switching the tool on check that it is not in contact with anything and is clear of the working surface or metal objects 2 Switch the tool on by pressing the on off button All symbols are shown in the display within 1 second After carrying out a brief self test the tool begins to calibrate itself automatically The status LEDs light green as soon as this has been completed While the tool is calibrating itself hold it in the air at least 30 cm 12 in away from any metal objects and away from the surface on which you are working 6 2 Working with the
15. within its specified limits d Observe the accident prevention regulations ap plicable in your country 4 3 Electromagnetic compatibility Although the tool complies with the strict requirements of the applicable directives Hilti cannot entirely rule out the possibility of the tool being subject to interference caused by powerful electromagnetic radiation leading to incor rect operation Check the accuracy of the tool by taking measurements by other means when working under such conditions or if you are unsure Likewise Hilti cannot rule out the possibility of interference with other devices e g aircraft navigation equipment The tool complies with the requirements of class A The possibility of interference occurring in a domestic environment cannot be excluded 4 4 General safety instructions 8 b Check the condition of the tool before use If the tool is found to be damaged have it repaired at a Hilti service center The user must check the accuracy of the tool after it has been dropped or subjected to other mechanical stresses Although the tool is designed for the harsh con ditions of jobsite use as with other measuring instruments it should be treated with care Although the tool is protected to prevent entry of dampness it should be wiped dry each time before being put away in its transport container Check to ensure that all symbols are visible when the tool is switched on f Check the accuracy of the to
16. y original 18 El These numbers refer to the corresponding illustra tions The illustrations can be found on the fold out cover pages Keep these pages open while studying the oper ating instructions In these operating instructions the designation the tool always refers to the PS 30 Ferrodetector Parts operating controls and indicators Kll D On off button Display Status LEDs red green Marking opening Battery compartment 1 General information 1 1 Safety notices and their meaning DANGER Draws attention to imminent danger that will lead to serious bodily injury or fatality WARNING Draws attention to a potentially dangerous situation that could lead to serious personal injury or fatality CAUTION Draws attention to a potentially dangerous situation that could lead to slight personal injury or damage to the equipment or other property NOTE Draws attention to an instruction or other useful informa tion 1 2 Explanation of the pictograms and other information Warning signs General warning Symbols Read the Return waste operating material for instructions recycling before use Location of identification data on the tool to it when making an enquiry to your Hilti representative The type designation and serial number can be found on service department the type identification plate on the tool Make a note of this data in your operating instructions and always refer Type

Download Pdf Manuals