Home
        Bedienungsanleitung de Operating instructions en Mode d
         Contents
1.     Serial no      2 Description    2 1 Use of the product as directed  The Hilti PS 30 Ferrodetector is designed to detect ferrous metals  steel rebars  and non ferrous metals  copper and  aluminium    The tool is not suitable for locating tensioning cables   The tool and its ancillary equipment may present hazards when used incorrectly by untrained personnel or when used  not as directed   Observe the information printed in the operating instructions concerning operation  care and maintenance   Take the influences of the surrounding area into account  Do not use the tool or appliance where there is a risk of fire  or explosion   Modification of the tool is not permissible     2 2 Display  The settings and tool status are shown in the display     2 3 Display illumination  The display illumination switches on automatically in conditions of low ambient light     2 4 Display    Areas of the display    Status area          Detection area          Shows the two areas of the display     2 5 Status indicator    Status area         x E                    Ferrous metal object          Non ferrous metal object          Audible signal off       OIOI    Battery status       Shows which status is active    2 6 Symbols in the display  Audible signal active  left     4           igh   9X      11       2 7 Warnings and error symbols in the display    Error message          Temperature warning    eL     Electromagnetic interference       gt     Calibration warning      gt     Contact Hilti s
2.  end of their  life must be collected separately and returned to an environmentally compatible recycling facility     11 Manufacturer   s warranty    Hilti warrants that the tool supplied is free of defects in  material and workmanship  This warranty is valid so long  as the tool is operated and handled correctly  cleaned  and serviced properly and in accordance with the Hilti  Operating Instructions  and the technical system is main   tained  This means that only original Hilti consumables   components and spare parts may be used in the tool     This warranty provides the free of charge repair or re   placement of defective parts only over the entire lifespan  of the tool  Parts requiring repair or replacement as a  result of normal wear and tear are not covered by this  warranty     Additional claims are excluded  unless stringent na   tional rules prohibit such exclusion  In particular  Hilti  is not obligated for direct  indirect  incidental or con   sequential damages  losses or expenses in connec   tion with  or by reason of  the use of  or inability to  use the tool for any purpose  Implied warranties of  merchantability or fitness for a particular purpose are  specifically excluded     For repair or replacement  send the tool or related parts  immediately upon discovery of the defect to the address  of the local Hilti marketing organization provided     This constitutes Hilti   s entire obligation with regard to  warranty and supersedes all prior or contemporaneous  c
3.  tool   Check that the tool makes full contact with the surface  you wish to scan    Use the tool only on smooth surfaces    Bring the tool slowly and carefully into contact with the  surface to be scanned    Do not move the tool at a speed greater than 20 cm s  9  in s     6 2 1 Sweep scan method                                     In order to achieve best results  the tool should be used  with a sweeping motion  extended horizontal and vertical   back and forward movements over the object   The series  of illustrations shows the sweep scan technique in use                          Switch the tool on and hold it at least 30 cm  12  in  away from any metal objects and away from the  surface on which you are working     2  Carefully bring the tool into contact with the surface    to be scanned and then begin to move it sideways   When the tool approaches a ferrous metal object  a  rebar   the  ferrous metal  symbol begins to blink   the status LEDs light red and the amplitude of the  signal strength indicator rises and reaches its max   imum when the tool is positioned over the center of  the object  If the tool is moved further until it is past  the ferrous metal  the status LEDs light green and  the signal strength indicator shows a decreasing  value  To obtain an exact indication of the position  of the rebar  the tool must be moved back in the  opposite direction until the status LEDs again light  red and the signal strength indicator shows the max   imum value  Use the ma
4. 20   C 10h   Operating temperature range  15    50      5   F to 122   F   Automatic cut out 5 min   Storage temperature range  dry   25     63 C   13     to 145  F   Relative air humidity 9596       Protection class    IP 54  protection against dust and water spray        Weight  including batteries     420 g  0 99 Ib        Dimensions  L x W x H     237 mm x 104 mm x 47 mm  9 4 in x 4 in x 2 in        4 Safety instructions    In addition to the information relevant to safety given  in each of the sections of these operating instructions   the following points must be strictly observed at all  times    The tool is designed to detect ferrous metals  steel  rebars  and non ferrous metals  copper  aluminium   in concrete  brick  drywall and under plaster surfaces  in accordance with the information provided in the  technical data section     4 1 Basic information concerning safety    a  Do not render safety devices ineffective and do  not remove information and warning notices    b  Keep children away from the tool        Check that the tool functions correctly each time  before use    d  Checkthe display after switching the tool on  The  display should show all symbols within 1 second        Check to ensure that the tool is able to calibrate  itself after switching on    f Operation of the tool in the proximity of pregnant  women is not permissible    9g  Rapidly changing detection conditions may lead to  inaccurate readings    h  Usethe tool only within its specified limits  
5. Do not  use the tool on materials containing tensioning  cables or stainless steel objects    ij Do not use the tool in the proximity of medical  instruments and appliances    j Do not drill at positions where the tool has located  an object    k  The warnings shown in the display must always  be observed      Do not use the tool in the proximity of electro    magnetic interference  e g  electric breakers in   operation     Take the influences of the surrounding area into   account  Do not use the tool where there is a risk   of fire or explosion     i    n  Make sure that the display area can be easily  read  e g  do not touch the display area with the  fingers  keep the display area clean     o  Do not use the tool if it is defective    p  Always keep the detection area clean    q  The accuracy of the tool is influenced by the base  material  If the tool is unable to calibrate itself cor   rectly  scanning errors may result    r  When the tool is unable to calibrate itself automatic   ally  a warning appears in the display    S  Use ofthe tool in the proximity of persons with a  cardiac pacemaker is not permissible     4 2 Proper organization of the workplace        Avoid unfavorable body positions when working  on ladders or scaffolding  Make sure you work  from a safe stance and stay in balance at all  times    b  Whenthe tool is brought into a warm environment  from very cold conditions  or vice versa  allow it  to become acclimatized before use        Use the tool only 
6. eile    PS 30    Bedienungsanleitung  Operating instructions  Mode d emploi   Istruzioni d uso   Manual de instrucciones  Manual de instru    es  Gebruiksaanwijzing  Brugsanvisning  Bruksanvisning  Bruksanvisning   Kayttoohje                  xanosuc   Hasznalati utasitas  Instrukeja obstugi                                                      N  vod k obsluze   N  vod na obsluhu   Upute za uporabu   Navodila za uporabo                                                    Instructiuni de utilizare  Kulllanma Talimat    Lieto  anas pam  c  ba  Instrukcija   Kasutusjuhend                        3                                                 te      R HE  RPA                                                                                          Printed  07 07 2013   Doc Nr  PUB   5137821   000   00    ORIGINAL OPERATING INSTRUCTIONS    PS 30 ferrodetector    It is essential that the operating instructions  are read before the tool is operated for the  first time     Always keep these operating instructions to   gether with the tool     Ensure that the operating instructions are  with the tool when it is given to other persons           Contents Page  1 General information 10  2 Description 11  3 Technical data 12  4 Safety instructions 13  5 Before use 14  6 Operation 15  7 Care and maintenance 16  8 Troubleshooting 16  9 FCC statement  applicable in US    ICES   statement  applicable in Canada  17  10 Disposal 17  11 Manufacturer s warranty 17  12 EC declaration of conformit
7. erature limits for storage of your equipment  must be observed  especially in winter   summer     7 2 Storage   Remove the tool from its case if it has become wet   The tool  its carrying case and accessories should be  cleaned and dried  at maximum 40  C   104  F   Repack  the equipment only once it is completely dry   Check the accuracy of the equipment before it is used  after a long period of storage or transportation    Remove the batteries from the tool before storing it for a  long period  Leaking batteries may damage the tool     7 3 Transport   Use the Hilti toolbox or packaging of equivalent quality  for transporting or shipping your equipment  Store the  tool safely     CAUTION  Always remove the batteries before shipping the tool     7 4 Hilti calibration service    We recommend that the tool is checked by the Hilti cal   ibration service at regular intervals in order to verify its  reliability in accordance with standards and legal require   ments    Use can be made of the Hilti calibration service at any  time  but checking at least once a year is recommended   The calibration service provides confirmation that the  tool is in conformance  on the day it is tested  with the  specifications given in the operating instructions    The tool will be readjusted if deviations from the man   ufacturer s specification are found  After checking and  adjustment  a calibration sticker applied to the tool and  a calibration certificate provide written verification that  the t
8. ervice    Inadmissible operating range    Too much interference from the surroundings    Calibration is required       2 8 Battery condition indicator    Number of segments shown  3   2   1   0   Battery symbol blinks    2 9 Items supplied   Tool   Hand strap   Soft pouch   Operating instructions    Batteries    PO BR aA a a a a    Markers    Manufacturer   s certificate    Charge status in      100   capacity     80   capacity     50   capacity     20   capacity     fully discharged    3 Technical data    Right of technical changes reserved     NOTE    All values apply to individual rod like metal objects positioned at right angles to the direction of movement of the  detector and when the surface of the concrete is flat and smooth with no external interference factors  Detection range  and accuracy is reduced when measurements are taken on brickwork     PS 30    Detection range for locating ferrous metals  gt  8mm     3   5   120 mm  74         4  in     2 6   8 mm  5   100 mm  74 in    4 in        Detection range for locating non ferrous metals  copper Diameter at least 10 mm  7 in   Pipe wall thickness at    and aluminium pipes     least 2 mm  3 2 in   5   80 mm            3  s in     Localization accuracy     10 mm  x   in        Minimum distance between objects    Depth range 5   55 mm       21 s        55 mm  2  s in   Depth range  gt 55 mm  21    in   Distance   depth factor  21 5                      Power source 4x1 5V  AAA  LROS alkaline batteries  Battery life at 
9. itions     1  This device may not cause interference not in compli   ance with the standards     2  This device must accept any interference received  in   cluding interference that may cause undesired operation     NOTE  Changes or modifications not expressly approved by Hilti  could void the user s authority to operate the equipment        PS 30 01    Hilti trademark of Hilti Corp   Schaan  LI Made in Malaysia    This device complies with part 15 of the FCC Rules  Operation is subject to the condition that this device does not                           Te Gass ns D oka ees      complies wih Canadian IGES O08 Get apparel num  rique dela casse  B        ct conforme    la norme NMB 0S du Canad  Power  6V 140 mA    4025 FE        G    ALR  o  8          Item No   Serialnumber                    10 Disposal    EO    Most of the materials from which Hilti tools or appliances are manufactured can be recycled  The materials must be  correctly separated before they can be recycled  In many countries  Hilti has already made arrangements for taking  back old tools or appliances for recycling  Ask Hilti Customer Service or your Hilti representative for further information     For EC countries only       Do not dispose of electronic measuring tools or appliances together with household waste   In observance of the European Directive on waste electrical and electronic equipment and its imple     mentation in accordance with national law  electric tools and batteries that have reached the
10. ol before using it for  detection or measurement     4 5 Electrical safety         b     Keep the batteries out of reach of children    Do not allow the batteries to overheat and do not  expose them to fire  The batteries may explode or  release toxic substances    Do not charge the batteries    Do not solder the batteries into the tool    Do not discharge the batteries by short circuiting   This may cause them to overheat and present a risk  of personal injury  burns     Do not attempt to open the batteries and do not  subject them to excessive mechanical stress     4 6 Transport    Always remove the batteries before shipping the tool     5 2 Checking the tool       5 1 Inserting the batteries El    CAUTION  Do not use damaged batteries     CAUTION  Always replace the complete set of batteries     DANGER  Do not mix old and new batteries  Do not mix batteries  of different makes or types     1     14    Open the battery compartment    Remove the batteries from the packaging and insert  them in the tool    NOTE Take care to observe correct polarity  see  symbols in battery compartment     Check to ensure that the battery compartment cover  is closed correctly     1     2     Check to ensure that the sensor area is not damp  If  necessary  use a cloth to dry the sensor area    For accurate results  allow the tool to acclimatize  itself to the ambient conditions before switching it  on if it has previously been exposed to extreme  temperature fluctuations     5 3 Switching the 
11. omments and oral or written agreements concerning  warranties     12 EC declaration of conformity  original           Designation  Ferrodetector  Type  PS 30  Year of design  2009    We declare  on our sole responsibility  that this product  complies with the following directives and standards   2011 65 EU  2006 95 EC  2004 108 EC  EN ISO 12100     Hilti Corporation  Feldkircherstrasse 100   FL 9494 Schaan    JL  mE    Paolo Luccini   Head of BA Quality and Process Man   agement   Business Area Electric Tools  amp  Ac   cessories   01 2012                   Matthias Gillner  Executive Vice President    Business Area Electric    Tools  amp  Accessories  01 2012    Technical documentation filed at     Hilti Entwicklungsgesellschaft mbH  Zulassung Elektrowerkzeuge  Hiltistrasse 6   86916 Kaufering   Deutschland    ml  m m    Hilti Corporation  11 9494 Schaan  Tel   4423 23421 11  Fax  4423 23429 65  www hilti com       Hilti   registered trademark of Hilti Corp   Schaan   W 3654   0313   10 Pos  1   1   Printed in Germany   2013   Right of technical and programme changes reserved S       amp      404004                 
12. ool operates in accordance with the manufacturer s  Specification    Calibration certificates are always required by companies  certified according to ISO 900x    Your local Hilti Center or representative will be pleased  to provide further information        8 Troubleshooting    Fault Possible cause    Remedy       The tool can t be switched on     The battery is exhausted     Replace the battery        The battery is inserted the wrong way    Insert the battery correctly     round  incorrect polarity      The battery compartment is not    closed     Close the battery compartment        The tool can t calibrate itself       gt     The tool is too close to metal objects     Switch the tool off and then hold it   at least 30 cm  12 in  away from any  metal objects and away from the sur   face on which you are working before  switching it on again        The tool displays an electro   magnetic interference warning        gt     The tool is too close to a source of  electromagnetic interference     Keep the tool away from electromag   netic interference        The tool displays a temperature    warning  low     eL     The temperature is too high or too    Observe the operating temperature  range  technical data         9 FCC statement  applicable in US    ICES statement  applicable in Canada     This device complies with section 15 of the FCC stand   ards and fulfills the 1   requirements in accordance with  ICES 008 for class B     Operation is subject to the following two cond
13. rking pen supplied to mark  the position of the ferrous metal object through the  marking opening in the tool  If the loudspeaker has  been activated  a constant audible signal is emitted  so long as the tool is positioned over the ferrous  metal object    When the tool approaches a non ferrous metal ob   ject  copper  aluminium   the  non ferrous metal   symbol begins to blink  the status LEDs light red  and the amplitude of the signal strength indicator  rises and reaches its maximum when the tool is po   sitioned over the center of the object  If the tool is  moved further until it is past the non ferrous metal  object  the status LEDs light green and the signal  strength indicator shows a decreasing value  To ob   tain an exact indication of the position of the rebar   the tool must be moved back in the opposite dir   ection until the status LEDs again light red and the  signal strength indicator shows the maximum value   Use the marking pen supplied to mark the position  of the non ferrous metal object through the marking  opening in the tool  If the loudspeaker has been ac   tivated  a constant audible signal is emitted so long  as the tool is positioned over the non ferrous metal  object     15    EI     7 Care and maintenance    7 1 Cleaning and drying   1  Use only a clean  soft cloth for cleaning  If necessary   moisten the cloth slightly with pure alcohol or a little  water    NOTE Do not use any other liquids as these may  damage the plastic components    The temp
14. tool on   off    1   2     Switch the tool on by pressing the on off button   When the tool is already switched on  press the  on off button  The tool switches off    NOTE  f the tool is not used or an error message  is displayed  it switches itself off automatically after  five minutes  The tool switches itself off when the  batteries are discharged     5 4 Switching the audible signal on   off    1     Press the on off button for 5 seconds    The audible signal menu is displayed  If the audible  signal is already activated it can be deactivated by  pressing the on off button again    To switch the tool off  press the on off button for 5  seconds    Switch the tool on    The new settings are shown in the display and the  tool is ready for use     6 Operation    6 3 Locating objects       6 1 Preparing the tool for use    CAUTION  Always drill at a safe distance from objects you have  detected     1  Before switching the tool on  check that it is not in  contact with anything and is clear of the working  surface or metal objects    2  Switch the tool on by pressing the on off button   All symbols are shown in the display within 1 second   After carrying out a brief self test  the tool begins to  calibrate itself automatically  The status LEDs light  green as soon as this has been completed     While the tool is calibrating itself  hold it in the air at  least 30 cm  12 in  away from any metal objects and  away from the surface on which you are working     6 2 Working with the
15. within its specified limits    d  Observe the accident prevention regulations ap   plicable in your country     4 3 Electromagnetic compatibility    Although the tool complies with the strict requirements of  the applicable directives  Hilti cannot entirely rule out the  possibility of the tool being subject to interference caused  by powerful electromagnetic radiation  leading to incor   rect operation  Check the accuracy of the tool by taking  measurements by other means when working under such  conditions or if you are unsure  Likewise  Hilti cannot rule  out the possibility of interference with other devices  e g   aircraft navigation equipment   The tool complies with the  requirements of class A  The possibility of interference  occurring in a domestic environment cannot be excluded     4 4 General safety instructions    8     b     Check the condition of the tool before use  If the  tool is found to be damaged  have it repaired at a  Hilti service center    The user must check the accuracy of the tool  after it has been dropped or subjected to other  mechanical stresses    Although the tool is designed for the harsh con   ditions of jobsite use  as with other measuring  instruments it should be treated with care   Although the tool is protected to prevent entry  of dampness  it should be wiped dry each time  before being put away in its transport container   Check to ensure that all symbols are visible when  the tool is switched on     f    Check the accuracy of the to
16. y  original  18    El These numbers refer to the corresponding illustra   tions  The illustrations can be found on the fold out cover  pages  Keep these pages open while studying the oper   ating instructions    In these operating instructions  the designation  the tool   always refers to the PS 30 Ferrodetector     Parts  operating controls and indicators Kll   D On off button     Display  Status LEDs  red   green   Marking opening        Battery compartment    1 General information    1 1 Safety notices and their meaning  DANGER    Draws attention to imminent danger that will lead to  serious bodily injury or fatality     WARNING  Draws attention to a potentially dangerous situation that  could lead to serious personal injury or fatality     CAUTION   Draws attention to a potentially dangerous situation that  could lead to slight personal injury or damage to the  equipment or other property     NOTE  Draws attention to an instruction or other useful informa   tion     1 2 Explanation of the pictograms and other  information    Warning signs       General  warning    Symbols       Read the Return waste   operating material for  instructions recycling   before use     Location of identification data on the tool to it when making an enquiry to your Hilti representative  The type designation and serial number can be found on        service department    the type identification plate on the tool  Make a note of   this data in your operating instructions and always refer Type    
    