Distillation Troubleshooting

image

Contents

1. Background A chemical vacuum tower containing structured packing Fig 24 1a and 2 5 separated a heavy key HK component from an intermediate key IK component in its lower section There was a specification of 0 3 maximum IK in the bottom and 1 0 maximum HK in the vapor side product Feed to the column contained many other components that were lighter or heavier than the keys Problem While the bottom product was on specification the vapor side product contained about 10 HK which was several times higher that the design Troubleshooting Initial suspicion was a malfunction of the structured packing or the distributors The design height equivalent of a theoretical plate HETP was on the low side but not grossly so The lower bed was simulated by eight stages six or seven would have been a closer estimate The distributor design was found to be good and the distributor was successfully water tested and debugged at the manufacturer s shop before being installed in the tower The VLE data were examined While not perfect the volatility estimate was quite reasonable 36 Chapter 2 Where Fractionation Goes Wrong Mole 0 Stage Top Side draw Bottom number Figure 2 5 Composition profile pinpoints sensitivity of heavy key From Ref 254 273 Reproduced with permission Copyright 1996 AIChE All rights reserved Next plugging of the packing or distributors was suspected Extensive field tests described in detail in Case S
2. Problem Bottoms from a tower recovering methanol from a methanol water mix ture contained 6 ppm methanol exceeding the maximum specification of 4 ppm required for discharging to the ocean Investigation A consultant pointed out that unusual hydrogen bonding behavior had been reported at very low concentration of methanol in water He recommended use of the UNIQUAC equation Wilson s equation is generally the method of choice for alcohol water mixtures when there is no unusual behavior The more complex NRTL equation is the usual choice for systems that cannot be handled by Wilson s equation The UNIQUAC equa tion often applies to systems with chemicallike interactions i e hydrogen bonding which behaves like weak chemical bonding that neither Wilson s nor the NRTL equations can represent Solution Schedule constraints precluded independently developing UNIQUAC parameters Various process simulation packages were checked for methanol water VLE with Wilson s NRTL and UNIQUAC equations All of the equations in all of the packages gave essentially the same VLE except that UNIQUAC in one major Case Study 1 7 Diagrams Troubleshoot Acetic Acid Dehydration Simulation 9 simulator gave lower methanol relative volatilities by as much as 15 at very low methanol concentrations This package executed much slower than the other alternatives The only methanol concentration predictions that were in line with the field data came from
3. 10 1 1 Insufficient Degassing 484 10 1 2 Excess Line Pressure Drop 485 10 1 3 Vortexing 486 Leak at Draw Tray Starves Draw 486 Draw Pans and Draw Lines Plug Up 488 Draw Tray Damage Affects Draw Rates 488 Undersized Side Stripper Overhead Lines Restrict Draw Rates 488 Degassed Draw Pan Liquid Initiates Downcomer Backup Flood 489 Other Problems with Tower Liquid Draws 489 Liquid Entrainment in Vapor Side Draws 490 Reflux Drum Malfunctions 490 10 9 1 Reflux Drum Level Problems 490 10 9 2 Undersized or Plugged Product Lines 490 10 9 3 Two Liquid Phases 490 11 Tower Assembly Mishaps Number 5 on the Top 10 Malfunctions 491 11 1 11 2 11 3 11 4 11 5 11 6 11 7 11 8 11 9 11 10 11 11 11 12 11 13 Incorrect Tray Assembly 491 Downcomer Clearance and Inlet Weir Malinstallation 491 Flow Passage Obstruction and Internals Misorientation at Tray Tower Feeds and Draws 492 Leaking Trays and Accumulator Trays 493 Bolts Nuts Clamps 493 Manways Hatchways Left Unbolted 493 Materials of Construction Inferior to Those Specified 494 Debris Left in Tower or Piping 494 Packing Assembly Mishaps 495 11 9 1 Random 495 11 9 2 Structured 496 11 9 3 Grid 496 Fabrication and Installation Mishaps in Packing Distributors 496 Parts Not Fitting through Manholes 498 Auxiliary Heat Exchanger Fabrication and Assembly Mishaps 498 Auxiliary Piping Assembly Mishaps 498 xiv Contents 12 Difficulties during Start Up Shutdown Commissi
4. 3 2 2 Less Loadings above Feed 429 3 2 3 Trapping Lights and Quenching 429 3 2 4 Others 430 3 3 Superheat How It Impacts Towers 430 4 Tower Sizing and Material Selection Affect Performance 431 4 1 Undersizing Trays and Downcomers 431 4 2 Oversizing Trays 431 4 3 Tray Details Can Bottleneck Towers 433 4 4 Low Liquid Loads Can Be Troublesome 434 4 4 1 Loss of Downcomer Seal 434 4 4 2 Tray Dryout 435 4 5 Special Bubble Cap Tray Problems 436 4 6 Misting 437 4 7 Undersizing Packings 437 4 8 Systems Where Packings Perform Different from Expectations 437 e Contents xi 4 9 Packed Bed Too Long 438 4 10 Packing Supports Can Bottleneck Towers 439 4 11 Packing Hold downs Are Sometimes Troublesome 440 4 12 Internals Unique to Packed Towers 440 4 13 Empty Spray Sections 440 Feed Entry Pitfalls in Tray Towers 441 5 1 Does the Feed Enter the Correct Tray 441 5 2 Feed Pipes Obstructing Downcomer Entrance 441 5 3 Feed Flash Can Choke Downcomers 441 5 4 Subcooled Feeds Refluxes Are Not Always Trouble Free 442 5 5 Liquid and Unsuitable Distributors Do Not Work with Flashing Feeds 442 5 6 Flashing Feeds Require More Space 443 5 7 Uneven or Restrictive Liquid Split to Multipass Trays at Feeds and Pass Transitions 443 5 8 Oversized Feed Pipes 444 5 9 Plugged Distributor Holes 444 5 10 Low AP Trays Require Decent Distribution 445 Packed Tower Liquid Distributors Number 6 on the 6 1 6 2 6 3 6 4 6 5 6 6 6 7 6 8 6 10 6 11 6 1
5. and oper ation of distillation towers Invention and innovation in tower internals enhanced tower capacity and efficiency beyond previously conceived limits Gamma scans and laser guided pyrometers have provided troubleshooters with tools of which not so long ago they would only dream With all these advances one would expect the failure rate in distillation towers to be on the decline maybe heading towards ex tinction as we enter the 21 century Our recent survey of distillation failures 255 brought disappointing news Distillation failures are not on the path to extinction Instead the tower failure rate is on the rise and accelerating Our survey further showed that the rise is not because distillation is moving into new unchartered frontiers By far the bulk of the failures have been repetitions of previous ones In some cases the literature describes 10 20 repetitions of the same failure And for every case that is reported there are tens maybe hundreds that are not In the late 1980s I increased tray hole areas in one distillation tower in an attempt to gain capacity Due to vapor cross flow channeling a mechanism unknown at the time the debottleneck went sour and we lost 5 capacity Half a year of extensive troubleshooting gamma scans and tests taught us what went wrong and how to regain the lost capacity We published extensively on the phenomenon and how to avoid A decade later I returned to investigate why another debot
6. but none were found Solution The tower was returned to its previous mode of operation with the higher deethanizer control temperature
7. which would lead to a warmer rectifying section Indeed the second exception was simulated rectifying section temperatures 2 5 F warmer than measured What Does the Stabilizer Do At first glance this question appears stupid But it turned out to be the key for understanding the test versus the simulation discrepancy There was a tight specification on the content of C3 in the stabilizer bottoms An excessive amount of C3 would lead to excessive Reid vapor pressure RVP in the bottom which was undesirable For similar reasons it was desirable to minimize iC in the stabilizer bottom although there was no set specification In the bottoms nCa and heavier were desirable components and were to be maximized Any C5 and heavier and even C ending up in the overhead product incurred an economic penalty because the bottoms were far more valuable than the overheads There were no set specifications for any of these components With the above in mind what is the stabilizer actually doing Which pair is the key components Initially we thought it was iC4 nC4 but could it have been C3 iC4 nC4 Cs C3 Cs or maybe some other pair Computer simulations do not answer such questions Hengstebeck diagrams 211 described in detail in Ref 251 do Hengstebeck diagrams Fig 1 3 were prepared from the compositions cal culated by the simulation The HR and LR tests each require one Hengstebeck diagram for each choice of key components C3 iC4 iC4 n
8. Blanketing 607 24 1 1 Inadequate Venting 607 24 1 2 Excess Lights in Feed 608 Inadequate Condensate Removal 608 24 2 1 Undersized Condensate Lines 608 24 2 2 Exchanger Design 609 Unexpected Condensation Heat Curve 609 Problems with Condenser Hardware 610 Maldistribution between Parallel Condensers 611 Flooding Entrainment in Partial Condensers 611 Interaction with Vacuum and Recompression Equipment 612 Others 612 Misleading Measurements Number 8 on the Top 10 Malfunctions 613 Incorrect Readings 613 Meter or Taps Fouled or Plugged 614 Missing Meter 615 Incorrect Meter Location 615 Problems with Meter and Meter Tubing Installation 616 25 5 1 Incorrect Meter Installation 616 25 5 2 Instrument Tubing Problems 616 Incorrect Meter Calibration Meter Factor 617 Level Instrument Fooled 617 25 7 1 By Froth or Foam 617 25 7 2 By Oil Accumulation above Aqueous Level 618 25 7 3 By Lights 619 xx Contents 25 8 25 9 25 7 4 By Radioactivity Nucleonic Meter 619 25 7 5 Interface Level Metering Problems 619 Meter Readings Ignored 619 Electric Storm Causes Signal Failure 619 26 Control System Assembly Difficulties 620 26 1 26 2 26 3 26 4 No Material Balance Control 620 Controlling Two Temperatures Compositions Simultaneously Produces Interaction 621 Problems with the Common Control Schemes No Side Draws 622 26 3 1 Boil Up on TC AC Reflux on FC 622 26 3 2 Boil Up on FC Reflux on TC AC 623 26 3 3 Boil Up on FC R
9. Not Help 556 16 6 5 Trays Versus Packings 556 16 6 6 Larger Packings High Open Area Distributors Help 557 16 6 7 Increased Agitation 557 16 6 8 Larger Tower 557 16 6 9 Reducing Base Level 557 17 The Tower as a Filter Part A Causes of Plugging Number 1 on the Top 10 Malfunctions 558 17 1 17 2 17 3 17 4 17 5 Piping Scale Corrosion Products 558 Salting Out Precipitation 559 Polymer Reaction Products 560 Solids Entrainment in the Feed 561 Oil Leak 561 18 19 20 21 Contents 17 6 Poor Shutdown Wash Flush 562 17 7 Entrainment or Drying at Low Liquid Rates 562 17 8 Others 562 The Tower as a Filter Part B Locations of Plugging Number 1 on the Top 10 Malfunctions 18 1 Trays 563 18 2 Downcomers 564 18 3 Packings 565 18 4 How Packings and Trays Compare on Plugging Resistance 565 18 4 1 Trays versus Trays 565 18 4 2 Trays versus Packings 566 18 4 3 Packings versus Packings 567 18 5 Limited Zone Only 567 18 6 Draw Exchanger and Vent Lines 569 18 7 Feed and Inlet Lines 570 18 8 Instrument Lines 570 Coking Part of Number 1 on Tower Top 10 Malfunctions 19 1 Insufficient Wash Flow Rate Refinery Vacuum Towers 571 19 2 Other Causes Refinery Vacuum Towers 572 19 3 Slurry Section FCC Fractionators 573 19 4 Other Refinery Fractionators 574 19 5 Nonrefinery Fractionators 574 Leaks 20 1 Pump Compressor 575 20 2 Heat Exchanger 575 20 2 1 Reboiler Tube 575 20 2 2 Condenser Tube 576 20 2 3 Auxil
10. Towers 520 14 1 4 Other Unstable Chemical Towers 521 Contents XV 14 2 Explosions Due to Violent Reactions 523 14 3 Explosions and Fires Due to Line Fracture 524 14 3 1 C Ca Hydrocarbons 524 14 3 2 Overchilling 525 14 3 3 Water Freeze 526 14 3 4 Other 527 14 4 Explosions Due to Trapped Hydrocarbon or Chemical Release 527 14 5 Explosions Induced by Commissioning Operations 528 14 6 Packing Fires 529 14 6 1 Initiated by Hot Work Above Steel Packing 529 14 6 2 Pyrophoric Deposits Played a Major Role Steel Packing 530 14 6 3 Tower Manholes Opened While Packing Hot Steel Packing 532 14 6 4 Others Steel Packing Fires 532 14 6 5 Titanium Zinconium Packing Fires 533 14 7 Fires Due to Opening Tower before Cooling or Combustible Removal 533 14 8 Fires Caused by Backflow 534 14 9 Fires by Other Causes 535 14 10 Chemical Releases by Backflow 536 14 11 Trapped Chemicals Released 536 14 12 Relief Venting Draining Blowdown to Atmosphere 537 15 Undesired Reactions in Towers 539 15 1 Excessive Bottom Temperature Pressure 539 15 2 Hot Spots 539 15 3 Concentration or Entry of Reactive Chemical 539 15 4 Chemicals from Commissioning 540 15 5 Catalyst Fines Rust Tower Materials Promote Reaction 540 15 6 Long Residence Times 541 15 7 Inhibitor Problems 541 15 8 Air Leaks Promote Tower Reactions 542 15 9 Impurity in Product Causes Reaction Downstream 542 16 Foaming 543 16 1 What Causes or Promotes Foaming 543 16 1 1 Solids Corrosion Product
11. absorb all the heavy ends out of the gas Investigation The initial boiling point IBP of the lean oil leaving the still was low which indicated the presence of a substantial quantity of gasoline in the still bottom This suggested that the still was malfunctioning The still showed no signs of flooding The control temperature the overhead temperature and the reflux rate appeared to be at their design values The composition of the top product was not analyzed Solution The problem was caused by insufficient reflux rate The low reflux rate was unnoticed because of an incorrectly sized orifice plate in the still reflux line When the orifice plate was replaced and the correct reflux flow set the plant observed a large permanent increase in fuel usage and a large drop in the apparent quantity of absorption oil indicating that the gasoline was being stripped off the bottom Following this the plant absorber started functioning normally and absorbing heavy ends out of the gas Analysis The problem was particularly difficult to detect because of the unusual behavior of the overhead and bottom temperatures Normally when a substantial amount of light impurity is present in the bottom one would expect the bottom tem perature to drop when a substantial amount of heavy impurity is present in the column overhead one would expect this temperature to rise Over reboiling can bring the bot tom temperature back up but in such a case one would exp
12. accounting for dimerization correct Case Study 1 8 Everything Vaporized in a Crude Vacuum Tower Simulation 11 Analysis By examining the DRD one can easily conclude that there is something wrong with the model We know that there is no binary acetic acid water azeotrope at 1 atm The model ideal vapor phase is not capable of describing the system properly It is well known that carboxylic acids associate in the vapor phase and this has to be taken into account for example by vapor dimerization model 158 Dimer option 227 Solution Instead of Idel the Dimer option was selected 227 The DRD for the system changed tremendously see Fig 1 2b There are no more binary azeotropes between acetic acid and water or n butyl acetate After proper selection of the thermo dynamic model the distillation column converged quickly to the required high purity water specifications in the bottoms Morals It is important to select the proper thermodynamic model and carefully verify the behavior of the mixture Because of their visualization capabilities DRDs are extremely useful for eval uating thermodynamic models for ternary and quaternary mixtures CASE STUDY 1 8 EVERYTHING VAPORIZED IN A CRUDE VACUUM TOWER SIMULATION Contributed by W Randall Hollowell CITGO Lake Charles Louisiana Problem Atmospheric crude tower bottom was heated then entered a typical fuel type vacuum tower A hand drawn curve estimated the atmospheric cr
13. correlation s limitations must be fully explored In contrast to the letter writer s comment the problem is more acute in articles that are peer reviewed These contain correlations based on fundamental models that are inherently complex This complexity makes it very difficult to properly identify the limitations A peer review offers little help unless the reviewer spends several days checking the calculations This rarely happens The Smith correlation works very well for vacuum and atmospheric pressures perhaps up to 50 psia It was never intended to apply to 400 psia Unfortunately Smith s article only contained a hint of the pressure limitation but no firm statements to that effect It therefore went into the Evertrue simulator without a warning flag 24 Chapter 1 Troubleshooting Distillation Simulations above 50 psia In this case the 1960 correlation was found to work well This appears to be a case of two wrongs making a right Epilogue There are many correlations in the published and proprietary literature for which the limitations are neither well explored nor well defined Limitations unflagged in the original articles remain unflagged in the simulator version Despite the letter writer s wrong conclusion his bottom line is broadly valid A simulator correlation cannot be trusted even when the correlation is good unless the correlation s limitations are known and included in the simulation An independent verificatio
14. fit to experimental data many of which were generated by suppliers and was later endorsed by Strigle 473 with a slight change of coefficient For the high capacity packing in the vacuum tower the packing factor was 12 Equation 1 predicts that APgooa was 0 65 in H2O ft packing which coincided with the limit observed by the refinery For hydraulic calculations gas velocity usually is expressed as a C factor Cs ft s given by 0 5 Gai Pc D PL PG where Us is the gas superficial velocity based on tower cross sectional area ft s p is the density Ib ft and the subscripts G and L denote gas and liquid respectively The C factor essentially is a density corrected superficial velocity The fundamental relevance of the C factor is discussed elsewhere 251 Based on a flood pressure drop of 0 65 in H2O ft packing derived from Equation 1 the maximum efficient capacity of the new 3 in random packing cal culated by the Kister and Gill method 251 was at a C factor of 0 38 ft s This is about 17 higher than the maximum efficient capacity for the previous 2 in Pall rings just as the refinery observed According to the supplier s published hand correlation which we believe was similar to the one in the computer simulation the maximum efficient capacity of the packing was at a C factor of 0 43 ft s which is 13 higher than observed This high C factor matched a pressure drop of between 1 and 1 5 in H2O ft packing well abov
15. methanol product were predominantly water Problem Tower feed had been calculated with a standard gas processing vapor liquid liquid equilibrium VLLE method Peng Robinson equation of state A con sultant noted that the VLLE method applied only to aqueous phases that behaved like pure water and only to gas phase components that had low solubility in the aqueous phase The large methanol content of the aqueous phase invalidated these feed com position calculations Every gas component was far more soluble in the tower feed than estimated The preliminary tower design would have produced a methanol prod uct with such a high H2S vapor pressure that it could not be safely stored in the atmospheric tank Better Approach Gas solubility in a mixed non HC solvent methanol and water is a Henry s constant type of relationship for which process simulation packages often do not have the methods and or parameters required Addition of a pasteurization section to the top of a tower is a common fix for removing light impurities from the distillate product After condensing most of the overhead vapor a small overhead vent gas stream is purged out of the tower to remove light ends Most or all of the overhead liquid is refluxed to minimize loss of desired product in the purges The pasteurization section typically contains 3 10 trays or a short packed bed used to separate light ends from the distillate product The distillate product is taken as a li
16. pleased to hear any comments experiences or challenges any readers may wish to share for possible inclusion in a future edition Also the author is sure that despite his intensive literature search he missed several invaluable references and would be very grateful to receive copies of such references Feedback on any errors as well as rebuttal to any of the experiences described is also greatly appreciated and will help improve future editions Please write fax or e mail to Henry Z Kister Fluor 3 Polaris Way Aliso Viejo CA 92698 phone 1 949 349 4679 fax 1 949 349 2898 e mail henry kister fluor com xxix This page intentionally left blank Abbreviations AC AGO aMDEA AMS APC AR ASTM atm B barg BFW BMD BPD BPH BSD BTEX BTX C Co C3 CAT Cat C factor CFD CHP CO Co CS CT CTC CW CWR CWS D D86 Analyzer control Atmospheric gas oil Activated MDEA Alpha methyl styrene adaptive process control on line analyzer American Society for Testing and Materials atmospheres atmospheric Bottoms bars gauge Boiler feed water 2 bromomethyl 1 3 dioxolane Barrels per day Barrels per hour bottom side draw Benzene toluene ethylbenzene xylene Benzene toluene xylene Number of carbon atoms in compound computed axial tomography Catalytic Vapor capacity factor defined by equation 2 in Case Study 1 14 computational fluid dynamics cumene hydroperoxide Carbon dioxide Company C
17. separation of benzene from toluene or ethanol from water estimating efficiency is quite trouble free in conventional trays and pack ings Problems are experienced in a first of a kind process or when a new mass transfer device is introduced and is on the steep segment of its learning curve Incorrect representation of the feed entry is troublesome if the first product leaves just above or below or if some chemicals react in the vapor and not in the liquid A typical example is feed to a refinery vacuum tower where the first major product exits the tower between 0 5 and 2 stages above the feed The presentation of liquid and vapor rates in the simulation output is not always user friendly especially near the entry of subcooled reflux and feeds often concealing higher vapor and liquid loads This sometimes precipitates underestimates of the vapor and liquid loads in the tower Misleading hydraulic predictions from simulators is a major troublespot Most troublesome have been hydraulic predictions for packed towers which tend to be optimistic using both the simulator methods and many of the vendor methods in the simulator 247 254 Simulation predictions of both tray and packing efficiencies as well as downcomer capacities have also been troublesome Further discussion is in Ref 247 CASE STUDY 1 1 METHANOL IN C SPLITTER OVERHEAD Installation Olefins plant C splitter separating propylene overhead from propane at pressures of 220 240 psi
18. varying the reflux rate as in normal operation one could keep the top temperature at its design value Variations of the column overhead temperature are shown in Figure 2 3b Un der all these conditions bottom temperature was controlled at 525 550 F The col umn overhead initially operated at point A at the low reflux conditions At the cor rect reflux rate the overhead temperature operated at point B Note the existence of point C on this curve at which an increase in reflux rate causes an increase in overhead temperature This operating condition point C has actually been observed in this type of column CASE STUDY 2 7 COMPOSITION PROFILES ARE KEY TO MULTICOMPONENT DISTILLATION Contributed by Frank Wetherill retired C F Braun Inc Alhambra California Installation A product column in a specialty chemical plant producing a heavy water soluble glycol product The process is similar to that described in Case Study 15 1 The column separated glycol product from high boiling residues The column is shown in Figure 2 4a Problem Although water was removed from the column feed and water forming reactions were suppressed by lowering the base temperature in a manner similar to that described in Case Study 15 1 a very small quantity of water about 0 1 was still present in the product It was economical to remove even that amount of water from the product Investigation This amount of water was very small and could have originate
19. xxix Abbreviations xxxi 1 10 Troubleshooting Distillation Simulations Where Fractionation Goes Wrong Energy Savings and Thermal Effects Tower Sizing and Material Selection Affect Performance Feed Entry Pitfalls in Tray Towers Packed Tower Liquid Distributors Number 6 on the Top 10 Malfunctions Vapor Maldistribution in Trays and Packings Tower Base Level and Reboiler Return Number 2 on the Top 10 Malfunctions Chimney Tray Malfunctions Part of Number 7 on the Top 10 Malfunctions Draw Off Malfunctions Non Chimney Tray Part of Number 7 on the Top 10 Malfunctions 25 61 73 97 111 133 145 163 179 vii viii 1 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Contents Tower Assembly Mishaps Number 5 on the Top 10 Malfunctions Difficulties During Start Up Shutdown Commissioning and Abnormal Operation Number 4 on the Top 10 Malfunctions Water Induced Pressure Surges Part of Number 3 on the Top 10 Malfunctions Explosions Fires and Chemical Releases Number 10 on the Top 10 Malfunctions Undesired Reactions in Towers Foaming The Tower as a Filter Part A Causes of Plugging Number 1 on the Top 10 Malfunctions The Tower as a Filter Part B Location of Plugging Number 1 on the Top 10 Malfunctions Coking Number 1 on the Top 10 Malfunctions Leaks Relief and Failure Tray Packing and Tower Damage Part of Numbe
20. xxxiii Hydrogen sulfide Hydroxyl amine Hazard and operability study Hydrocarbon Heavy coker gas oil Hydrogen chloride Hydrogen cyanide Heavy cycle oil Heavy diesel Height equivalent of a theoretical plate Hydrogen fluoride Mercury Heavy key Heavy naphtha High pressure High reflux Heat stable salts hand valve Heavy vacuum gas oil Initial boiling point intermediate cycle oil Internal diameter Intermediate key inch Isopropyl alcohol Isopropyl ether Infrared Internal vapor control Kilopascals Kilopascals gage pounds Level control Light coker gas oil Light cycle oil Light diesel Level indicator Light key Liquid liquid Log mean temperature difference Low pressure Loss Prevention Bullletin Liquefied petroleum gas refers to C3 and C4 hydrocarbons Low reflux Level transmitter Liquid to vapor molar ratio xxxiv LVGO m MB MDEA MEA MEK MF min MISO MNT MOC MP MPC mpy MSDS MTS MV MVC N2 NC NGL NNF NPSH NRTL NRU ORS OSHA PA P amp ID PC PCV PI PR psi psia psig PSV PVC PVDF R22 Abbreviations Light vacuum gas oil meters Material balance Methyl diethanol amine Monoethanol amine Methyl ethyl ketone Main fractionator Minutes or minimum Multiple inputs single output millimeters Mononitrotoluene Management of change Medium Pressure Model predictive control mils per year refers to a measure of conosion rates 1 mil is 1 1000 inch
21. 2 6 13 Top 10 Malfunctions 446 Better Quality Distributors Improve Performance 446 6 1 1 Original Distributor Orifice or Unspecified 446 6 1 2 Original Distributor Weir Type 447 6 1 3 Original Distributor Spray Type 447 Plugged Distributors Do Not Distribute Well 448 6 2 1 Pan Trough Orifice Distributors 448 6 2 2 Pipe Orifice Distributors 449 6 2 3 Spray Distributors 450 Overflow in Gravity Distributors Death to Distribution 451 Feed Pipe Entry and Predistributor Problems 454 Poor Flashing Feed Entry Bottleneck Towers 455 Oversized Weep Holes Generate Undesirable Distribution 456 Damaged Distributors Do Not Distribute Well 457 6 7 1 Broken Flanges or Missing Spray Nozzles 457 6 7 2 Others 457 Hole Pattern and Liquid Heads Determine Irrigation Quality 458 Gravity Distributors Are Meant to Be Level 459 Hold Down Can Interfere with Distribution 460 Liquid Mixing Is Needed in Large Diameter Distributors 460 Notched Distributors Have Unique Problems 461 Others 461 xii Contents 7 Vapor Maldistribution in Trays and Packings 462 7 1 Vapor Feed Reboiler Return Maldistributes Vapor to Packing Above 462 7 1 1 Chemical Gas Plant Packed Towers 462 7 1 2 Packed Refinery Main Fractionators 463 7 2 Experiences with Vapor Inlet Distribution Baffles 465 7 3 Packing Vapor Maldistribution at Intermediate Feeds and Chimney Trays 465 7 4 Vapor Maldistribution Is Detrimental in Tray Towers 466 7 4 1 Vapor Cross Flow Channeling 466 7 4
22. 2 Multipass Trays 467 7 4 3 Others 467 8 Tower Base Level and Reboiler Return Number 2 on the Top 10 Malfunctions 468 8 1 Causes of High Base Level 468 8 1 1 Faulty Level Measurement or Level Control 468 8 1 2 Operation 469 8 1 3 Excess Reboiler Pressure Drop 470 8 1 4 Undersized Bottom Draw Nozzle or Bottom Line 470 8 1 5 Others 470 8 2 High Base Level Causes Premature Tower Flood No Tray Packing Damage 470 8 3 High Base Liquid Level Causes Tray Packing Damage 471 8 4 Impingement by the Reboiler Return Inlet 472 8 4 1 On Liquid Level 472 8 4 2 On Instruments 473 8 4 3 On Tower Wall 473 8 4 4 Opposing Reboiler Return Lines 474 8 4 5 On Trays 474 8 4 6 On Seal Pan Overflow 474 8 5 Undersized Bottom Feed Line 475 8 6 Low Base Liquid Level 475 8 7 Issues with Tower Base Baffles 476 8 8 Vortexing 476 9 Chimney Tray Malfunctions Part of Number 7 on the Top 10 Malfunctions 477 9 1 Leakage 477 9 2 Problem with Liquid Removal Downcomers or Overflows 478 9 3 Thermal Expansion Causing Warping Out of Levelness 479 9 4 Chimneys Impeding Liquid Flow to Outlet 480 Contents xiii 9 5 Vapor from Chimneys Interfering with Incoming Liquid 480 9 6 Level Measurement Problems 481 9 7 9 8 Coking Fouling Freezing 482 Other Chimney Tray Issues 482 10 Drawoff Malfunctions Non Chimney Tray Part of Number 7 on the Top 10 Malfunctions 484 10 1 10 2 10 3 10 4 10 5 10 6 10 7 10 8 10 9 Vapor Chokes Liquid Draw Lines 484
23. A PINCH Henry Z Kister references 254 276 Reproduced with permission Copyright 1995 AIChE All rights reserved A composition pinch occurs when due to an insufficient driving force the change in composition on each successive distillation stage diminishes and approaches zero In the stripping section an insufficient driving force usually coincides with an exces sively low stripping ratio V B Increasing the stripping ratio can reinstate compo sition changes but at the expense of higher vapor and liquid hydraulic load These higher loads cannot be tolerated when the tower nears a capacity bottleneck In this case a clever debottleneck scheme looked great on the simulation Yet pinches and mislocated feeds readily visible on McCabe Thiele diagrams remain hidden on computer screens It took a McCabe Thiele diagram 341 described in detail in Ref 251 to see that the scheme would drive the tower too close to a pinch and would be risky Fortunately the McCabe Thiele diagram was prepared before the scheme was implemented Background An olefins plant was being debottlenecked for a 15 increase in throughput The C2 splitter Fig 2 2a was a major bottleneck The tower contained 95 trays in the rectifying section and 45 trays in a smaller diameter stripping section The vapor feed entered close to its dew point Case Study 2 5 Interreboiler Drives Tower to a Pinch 29 Reflux Feed source 1 60 feed New interreboiler s
24. C4 and nC4 iCs A Hengstebeck diagram for the iC4 nC4 separation was included in a more detailed description of the case 254 and showed that this pair behaved the same as the C3 iC4 pair Figure 1 3a shows that in the HR test below the feed the stabilizer effectively separated C3 and lighter from iC and heavier The diagram also shows that a lim ited degree of separation of these components occurred in the top two stages of the rectifying section but pinching occurred below these Overall very little separation of C3 and lighter from iC and heavier occurred in the rectifying section The sta bilizer essentially behaved as a stripper for separating C3 and lighter from iC and heavier Figure 1 3b shows that in the HR test above the feed the stabilizer effectively separated nC and lighter from iC and heavier It also illustrates that some separation of these components took place in the bottom five stages of the stripping section but pinching occurred above these Together Figures 1 3a and b underscore that the stripping section of the stabilizer separated C3 and lighter from iC and heavier and per Ref 254 also iC and lighter from nC and heavier The rectifying section of the stabilizer separated iC and heavier from nC and lighter 16 Chapter 1 Troubleshooting Distillation Simulations Mole fraction C and lighter in vapor Xp 9 789 0 0 2 0 4 0 6 0 8 1 Mole fraction C and lighter in liquid Mole fraction nC and
25. Distillation Troubleshooting Henry Z Kister Fluor Corporation AIChE CIN LEY INTERSCIENCE A JOHN WILEY amp SONS INC PUBLICATION This page intentionally left blank Distillation Troubleshooting This page intentionally left blank Distillation Troubleshooting Henry Z Kister Fluor Corporation AIChE Qe LEY INTERSCIENCE A JOHN WILEY amp SONS INC PUBLICATION DISCLAIMER The author and contributors to Distillation Troubleshooting do not represent warrant or otherwise guarantee expressly or impliedly that following the ideas information and recommendations outlined in this book will improve tower design operation downtime troubleshooting or the suitability accuracy reliability or completeness of the information or case histories contained herein The users of the ideas the information and the recommendations contained in this book apply them at their own election and at their own risk The author and the contributors to this book each expressly disclaims liability for any loss damage or injury suffered or incurred as a result of or related to anyone using or relying on any of the ideas or recommendations in this book The information and recommended practices included in this book are not intended to replace individual company standards or sound judgment in any circumstances The information and recommendations in this book are offered as lessons from the past to be considered for the de
26. Material safety data sheets Refers to a proprietary liquid distributor marketed by Sulzer under license from Dow Chemical Manual valve Multivariable control or more volitle component nitrogen Normally closed Natural gas liquids Normally no flow Normally open Net positive suction head Nonrandom two liquid refers to a popular VLE prediction method Nitrogen rejection unit oxygen Oxide redistillation still Occupational Safety and Health Administration Pumparound Process and instrumentation diagram Pressure control Pressure control valve Pressure indicator Peng Robinson refers to a popular VLE prediction method pounds per square inch psi absolute psi gauge Pressure safety valve Pressure transmitter Polyvinyl chloride Polyvynilidene fluoride Freon 22 Ref Refrig RO RVP SBE sec SG SPA SRK SS STM T A TBP TC TCE TDC TEA TEG TI Ti TRC UNIQAC VAM V B VCFC VCM VGO VLE VLLE VOC vol w g wt AP AT Abbreviations XXXV Reflux to distillate molar ratio Reference Refrigeration Restriction orifice Reid vapor pressure seconds Di Sec butyl ether secondary specific gravity Slurry pumparound Soave Redlich and Kwong refers to a popular VLE method Stainless steel Steam Turnaround True boiling point Temperature control Trichloroethylene Temperature difference controller Triethanol amine Triethylene glycol Temperature indicator Titanium temperature re
27. a high activity coefficient making it very volatile in the wastewater Poor ventilation typical of sewer systems did not allow the benzene to disperse and it concentrated in the vapor space above the wastewater The lower explosive limit of benzene in air is quite low about a few percent and it is believed that the benzene concentration exceeded it at least in some locations in the sewer system The sewer system had one vent pipe discharging at ground level without a goose neck A worker was doing hot work near the top of that pipe Sparks are believed to have fallen into the pipe igniting the explosive mixture The pipe blew up into the worker s face killing him Morals Beware of high volatilities of HCs and organics in a wastewater system Avoid venting sewer systems at ground level Case Study 1 4 A Hydrocarbon VLLE Method Used For Aqueous Feed Equilibrium 5 CASE STUDY 1 4 A HYDROCARBON VLLE METHOD USED FOR AQUEOUS FEED EQUILIBRIUM Contributed by W Randall Hollowell CITGO Lake Charles Louisiana Installation Feed for a methanol water separation tower was the water methanol phase from a three phase gas oil aqueous separator Gas from the separator was moderately high in H2S and in CO2 Tower preliminary design used a total overhead condenser to produce 95 methanol Methanol product was cooled and stored at atmospheric pressure Off gas from storage was not considered a problem because the calculated impurities in the
28. able phase either into the reflux or into the product Presence or absence of a second liquid phase caused not only separation issues and production bottlenecks but in some cases also violent reactions damage and explosions Other fractionation issues include insufficient reflux insufficient stages insuffi cient stripping and excessive bottom temperatures Although basic to fractionation it is amazing how often it is overlooked Unique multicomponent issues include ab sorption effects in wide boiling mixtures and location of side draws Azeotropic and extractive distillation have their own unique challenges CASE STUDY 2 1 NO REFLUX NO SEPARATION Contributed by Ron F Olsson Celanese Corp The feed to a 55 tray tower came in 10 trays below the top The tower was separating an alcohol as the distillate from a glycol as a bottom product A simulation detected that the losses of glycol in the distillate were excessive The glycol losses were Distillation Troubleshooting By Henry Z Kister Copyright 2006 John Wiley amp Sons Inc 25 26 Chapter 2 Where Fractionation Goes Wrong estimated to cost about 250 000 per year Further investigation revealed that the reflux had been eliminated Apparently the reflux rate was cut out during the 1970s when energy savings were most important Over the years this mode of operation became the norm Further corrosion of the trays reduced their efficiency causing the separation to deterior
29. arbon steel Chimney Tray Carbon tetrachloride Cooling water Cooling water return Cooling water supply Distillate ASTM atmospheric distillation test of petroleum fraction xxxi xxxii DAA DC DC DC DC DC DCM DCS DEA DFNB DIB DMAC DMC DMF DMSO DO dP DQI DRD dT DT GC MS gpm GS H20 Abbreviations diacetone alcohol Demethanizer Deethanizer Depropanizer Debutanizer Depentanizer Dichloromethane Distributed control system Diethanol amine 2 4 difluoronitrobenzene Deisobutanizer dimethylacetamide Dynamic matrix control Dimethylformamide Dimethyl sulphoxide Decant oil Same as AP Distribution quality index distillation region diagram Same as AT Distillation troubleshooting this book Energy balance ethylbenzene extractive distillation Ethylene dichloride Ethylene glycol Ethylene glycol monoethy ether ethylene oxide End of run Ethylene tetrafluoroethylene a type of teflon Flow control Fluid catalytic cracker Flow indicator feet per hour Flow recorder Flow Switch Feet gallons Gas chromatographs Gas chromatography mass spectrometry gallons per minute A process of concentrating deutrium by dual temperature isotope exchange between water and hydrogen sulfide with no catalyst hours Hydrogen Water HaoS HA HAZOP HC HCGO HCl HCN HCO HD HETP HF Hg HK HN HP HR HSS HV HVGO IBP ICO LMTD LP LPB LPG LR LT L V Abbreviations
30. as in reasonable agreement with plant data Moral Crude oil high boiling point data are often poor and must be extrapolated Experience following good procedures and cross checks with plant data are essential for reliable results CASE STUDY 1 9 CRUDE VACUUM TOWER SIMULATION UNDERESTIMATES RESIDUE YIELD Contributed by W Randall Hollowell CITGO Lake Charles Louisiana Problem Process simulation estimated much lower vacuum residue yields than obtained from plant towers and from pilot unit runs Vacuum tower feed boiling point curves were based upon high temperature gas chromatography GC analyses Investigation Vacuum tower feed boiling point curves from the GC fell well below curves estimated from assays The GC analyses assumed that all of the feed oil vaporized in the test and was analyzed The highest boiling part of crude oil is too heavy to vaporize in a GC test Thus the reported GC results did not include the highest boiling part that above about 1250 F boiling point of the feed Simulations based upon this GC data estimated much higher vaporization than actual because they were missing the heaviest part of the feed Solution The GC method was modified to include a standard that allowed estima tion of how much oil remained in the GC column and was not measured New GC data and extrapolations of assay data indicated that 10 15 of the feed oil was not vaporized and thus had not been measured by the earlier GC method With th
31. ate The glycol losses were drastically cut once the reflux was reintroduced CASE STUDY 2 2 HEAVIER FEEDSTOCK IMPEDES STRIPPING Contributed by Dmitry Kiselev and Oleg Karpilovskiy Koch Glitsch Moscow Russia Installation A diesel hydrotreating unit was revamped to a dewaxing process Due to increase in production of wild naphtha and gases the diesel stabilizer was revamped also The revamp design proposed to use a fired heater reboiler to provide the desired diesel flash point The refinery did not have enough time to revamp the heater so the unit started with stripping steam injection under the bottom tray instead of the heater reboiler circuit Problem After several months of operation the refinery decided to complete the unit revamp The heater reboiling circuit was made operational while the steam line was disconnected The result was surprising The flash point of diesel decreased by 20 C even though design specifications of the reboiling circuit flow rate and heater outlet temperature were achieved Investigation The first suspicion was that tray damage occurred during start up but checking of this required a shutdown or gamma scans which were expensive options in that location A complete set of process data was collected instead and a tower simulation prepared The feed composition was surprisingly much heavier than design The ASTM D86 50 percent point increased from 265 to 320 C The reflux rate was half the design val
32. ause of the pinch an error in the rela tive volatility of the nC4 iCs and nC4 nCs pairs is not magnified in each separation stage Such an error therefore has little effect on the separation and the tempera ture profile For this reason the LR test simulation gave a good match to measured data Would the Inaccuracy Affect the Debottlenecking Predictions The simulation predicted higher Cs in the top product giving a conservative forecast of 18 Chapter Troubleshooting Distillation Simulations the stabilizer performance under test conditions The remaining question is whether the simulation will continue to give conservative predictions under different process conditions The question of extrapolating test data into different process conditions is addressed rigorously on pp 400 405 of Ref 251 In fact the analysis in Ref 251 was part of the stabilizer debottlenecking assignment The conclusion reached was that when test data are simulated with too low a volatility the simulation compensates by using a greater number of stages and hence higher efficiencies to match the mea sured separation In this case e g the nC4 Cs pair in the stabilizer the simulation will continue to give conservative predictions when extrapolated into different process conditions The converse occurs when test data are simulated with too high a relative volatil ity The simulation compensates by using a smaller number of stages to match the measured separat
33. corder controller Unified quasi chemical refers to a popular VLE prediction method Vinyl acetate monomer Stripping ratio i e molar ratio of stripping section vapor flow rate to tower bottom flow rate Vapor cross flow channeling Vinyl chloride monomer Vacuum gas oil Vapor liquid equilibrium Vapor liquid liquid equilibrium Volatile organic carbon Volume water gage by weight Pressure difference Temperature difference This page intentionally left blank Chapter 1 Troubleshooting Distillation Simulations It may appear inappropriate to start a distillation troubleshooting book with a mal function that did not even make it to the top 10 distillation malfunctions of the last half century Simulations were in the 12th spot 255 Countering this argument is that simulation malfunctions were identified as the fastest growing area of distillation malfunctions with the number reported in the last decade about triple that of the four preceding decades 252 If one compiled a distillation malfunction list over the last decade only simulation issues would have been in the equal 6th spot Simulations have been more troublesome in chemical than in refinery towers probably due to the difficulty in simulating chemical nonidealities The subject was discussed in detail in another paper 247 The three major issues that affect simulation validity are using good vapor liquid equilibrium VLE predictions obtaining a good match bet
34. d either in the column feed or from water forming condensation reactions at the column base Tackling this problem at the source would have been difficult It was realized that the product was very hygroscopic Therefore it was suspected that after the product was condensed and subcooled in the overhead condenser it reabsorbed water from the inerts stream Solution It appeared beneficial to withdraw the product upstream of the point where it was being subcooled A suitable point was the top tray of the column The column was modified to withdraw product from this tray as shown in Figure 2 4b This eliminated the water problem Postmortem The relative volatility for glycol water separation was large the atmospheric boiling point of the glycol was greater than 400 F Any liquid water present in the reflux stream therefore easily vaporized on the top tray 34 Chapter 2 Where Fractionation Goes Wrong 10 mm Hg Inerts Product column Residues a 10 mm Hg Inerts Product column Residues b Figure 2 4 Glycol product column a initial b modified Case Study 2 8 Composition Profile Plot Troubleshoots Multicomponent Separation 35 It may appear that withdrawing water from the top tray instead of from the re flux drum would have enriched the product with the heavier impurity because the condenser stage was no longer available for the product residue separation This en richment however was minimal because eve
35. densate Unflooded Drum 637 28 2 2 Flooded Drum 637 28 2 3 Hot Vapor Bypass 637 28 2 4 Valve in the Vapor to the Condenser 639 Coolant Throttling Pressure Controls 640 28 3 1 Cooling Water Throttling 640 28 3 2 Manipulating Airflow 640 28 3 3 Steam Generator Overhead Condenser 640 28 3 4 Controlling Cooling Water Supply Temperature Pressure Control Signal 641 28 4 1 From Tower or from Reflux Drum 641 28 4 2 Controlling Pressure via Condensate Temperature Throttling Steam Vapor to Reboiler or Preheater 641 Throttling Condensate from Reboiler 642 Preheater Controls 643 Miscellaneous Control Problems Interaction with the Process 644 AP Control 644 Flood Controls and Indicators 644 Batch Distillation Control 645 Problems in the Control Engineer s Domain 645 Advanced Controls Problems 646 29 6 1 Updating Multivariable Controls 646 29 6 2 Advanced Controls Fooled by Bad Measurements 29 6 3 Issues with Model Inaccuracies 647 29 6 4 Effect of Power Dips 647 29 6 5 Experiences with Composition Predictors in Multivariable Controls 647 References 649 Index 669 About the Author 713 640 641 644 646 This page intentionally left blank Preface To every problem there s always an easy solution neat plausible and wrong Mencken s Maxim The last half century has seen tremendous progress in distillation technology The introduction of high speed computers revolutionized the design control
36. e moments of insight when all the facts you have been struggling with for months suddenly fall together into a simple explanation I hope this book helps to get you there HENRY Z KISTER March 2006 This page intentionally left blank Acknowledgments Many of the case histories reported in this book have been invaluable contributions from colleagues and friends who kindly and enthusiastically supported this book Many of the contributors elected to remain anonymous Kind thanks are due to all contributors Special thanks are due to those who contributed multiple case histories and to those whose names do not appear in print To those behind the scenes friends I extends special appreciation and gratitude Writing this book required breaking away from some of the everyday work demands Special thanks are due to Fluor Corporation particularly to my supervisors Walter Stupin and Paul Walker for their backing support and encouragement of this book writing effort going to great lengths to make it happen Recognition is due to my mentors who over the years encouraged my work immensely contributed to my achievements and taught me much about distillation and engineering To my life long mentor Walter Stupin who mentored and encouraged my work throughout my career at C F Braun and later at Fluor being a ceaseless source of inspiration behind my books and technical achievements Paul Walker Fluor whose warm encouragement and support
37. e the value where the packing reached a capacity limit Epilogue Based on the hydraulic calculation in the computer simulation the re finery expected that changing the 2 in Pall rings to the 3 in high capacity random packing would increase capacity by 30 In real life just over half of the capacity increase materialized The half that did not materialize is attributed to the optimistic prediction from the simulation 22 Chapter 1 Troubleshooting Distillation Simulations CASE STUDY 1 15 PACKING HYDRAULIC PREDICTIONS TO TRUST OR NOT TO TRUST Background This case presents a number of experiences which were very similar to Case Study 1 14 In each one of these vendor and simulator predictions for a packed tower were optimistic In each one of these the Kister and Gill equation 257 259 gave excellent prediction for the maximum capacity The Kister and Gill equation is A Paooa 0 115 F87 1 where APgood is the flood pressure drop in H2O ft packing and Fp is the packing factor ft7 Tower A This was a chemical tower equipped with wire mesh structured packing with a packing factor of 21 The tower ran completely smoothly until reaching a pressure drop of 1 in H O ft packing then would rapidly lose efficiency This com pares to a flood pressure drop of 0 97 in H2O ft packing from Equation 1 Simulation prediction both vendor and general options predicted a much higher capacity TowerB This was a chemical tower equip
38. ecomposition reaction took place near the bottom of one chemical tower yielding a corrosive compound The boiling point of that com pound was well below the tower overhead temperature It therefore accumulated and corroded trays in the middle of the tower CASE STUDY 2 10 HICCUPS IN A REBOILED DEETHANIZER ABSORBER Installation A refinery reboiled deethanizer absorber Fig 2 7 The top section of the tower used a naphtha stream to absorb C3 and C4 HCs from a gas stream that went to fuel gas Feed to the tower contained a small amount of water Free water was removed in the feed drum upstream of the tower but the separation was not perfect In addition the small quantity of water dissolved in the HC feed would not be removed in the feed drum Bottoms from the tower went to a debutanizer that operated much hotter than the deethanizer The debutanizer recovered the C3 and C4 HCs in the top product leaving gasoline as the bottom product Problem Plant economics favored maximizing recovery of C3 and C in the deeth anizer bottoms To achieve this the control temperature in the stripping section was lowered The system worked well for 2 3 days following the change Then the debu tanizer pressure suddenly shot up and a large slug of water was observed to fill the boot of the debutanizer reflux drum A few minutes later the water disappeared Two to three days later the process repeated The possibility of steam or water leaks was investigated
39. ect the top temperature to rise further above design The above considerations are generally valid for binary distillation and often but not always for multicomponent separations This case is an example of a multicom ponent distillation where the above considerations do not apply In general terms at the low reflux rates the column was operated as a gasoline LPG separator instead of an absorption oil gasoline LPG separator This lowered temperatures throughout However the column was over reboiled this returned the bottom and top temperatures to their design values This is explained in detail below At the low reflux ratio a substantial fraction of the gasoline reached the bottom This would have caused a lower temperature at the base of the column but the control system increased the reboil rate i e over reboiled to keep the bottom temperature up at design Because of the low reflux ratio however the over reboil action boiled over a significant fraction of absorption oil and perhaps most of the gasoline The Case Study 2 7 Composition Profiles Are Key to Multicomponent Distillation 33 column probably fractionated out most but not all of the absorption oil The mixture arriving at the top tray therefore contained the LPGs some gasoline and a small quantity of absorption oil The presence of the absorption oil acted to increase the top tray temperature the absence of gasoline that was lost to the bottom acted to decrease it By
40. ed recalibrated again Everything was OK As all of the above mentioned actions did not improve the product quality it seemed that something was wrong with the column After long discussions it was decided to open the handhole at the top of the column and to have a closer look at the feed distributor Nothing suspicious was found Then it was decided to have a closer look at the analysis again A gas chromatography mass spectrometry GC MS analysis was performed This method showed that the impurity was not the light boiling component as presumed This component was a remainder from the previous run in the multipurpose plant Having a boiling point much closer to the end product this component could not be separated in the column Moral Itis a good idea to check the analysis with GC MS before shutting down a column CASE STUDY 1 11 INCORRECT FEED CHARACTERIZATION LEADS TO IMPOSSIBLE PRODUCT SPECIFICATIONS Contributed by Chris Wallsgrove Installation A new entirely conventional depentanizer recovering a Cs distillate stream from a Cs C C 7 raffinate mixture from a catalytic reformer aromatics extrac tion unit with some light pyrolysis gasoline feed from an adjacent naphtha cracking ethylene plant The column had 30 valve trays a steam heated reboiler and a con denser on cooling water Problem The C distillate was guaranteed by the process licensor to contain a maximum of 0 5 wt C s Laboratory testing by the on site lab
41. eflux on LC 624 26 3 4 Boil Up on LC Bottoms on TC AC 625 26 3 5 Reflux on Base LC Bottoms on TC AC 626 Problems with Side Draw Controls 626 26 4 1 Small Reflux below Liquid Draw Should Not Be on Level or Difference Control 626 26 4 2 Incomplete Material Balance Control with Liquid Draw 628 26 4 3 Steam Spikes with Liquid Draw 628 26 4 4 Internal Vapor Control makes or Breaks Vapor Draw Control 628 26 4 5 Others 628 27 Where Do Temperature and Composition Controls Go Wrong 629 27 1 27 2 27 3 Temperature Control 629 27 1 1 No Good Temperature Control Tray 629 27 1 2 Best Control Tray 630 27 1 3 Fooling by Nonkeys 630 27 1 4 Averaging Including Double Differential 631 27 1 5 Azeotropic Distillation 631 27 1 6 Extractive Distillation 631 27 1 7 Other 632 Pressure Compensated Temperature Controls 632 27 2 1 AT Control 632 27 2 2 Other Pressure Compensation 633 Analyzer Control 633 27 3 1 Obtaining a Valid Analysis for Control 633 27 3 2 Long Lags and High Off Line Times 633 27 3 3 Intermittent Analysis 634 27 3 4 Handling Feed Fluctuations 635 27 3 5 Analyzer Temperature Control Cascade 635 27 3 6 Analyzer On Next Tower 635 Contents xxi 28 Misbehaved Pressure Condenser Reboiler and Preheater Controls 636 28 1 28 2 28 3 28 4 28 5 28 6 28 7 29 29 1 29 2 29 3 29 4 29 5 29 6 Pressure Controls by Vapor Flow Variations 636 Flooded Condenser Pressure Controls 637 28 2 1 Valve in the Con
42. en but the reflux rate was much lower than normal Investigations revealed that the feed to the unit had become considerably heavier For this heavier feed the operating bottom temperature was too low to provide sufficient stripping for H2S removal Solution Bottom operating temperature and reflux ratio were raised to ensure proper H2S removal Morals Tower operation needs to vary to accommodate changing feedstocks Op erators need to be trained to recognize the critical operating set points CASE STUDY 2 4 HEAVIES ACCUMULATION INTERRUPTS BOIL UP Contributed by Ron F Olsson Celanese Corp Figure 2 1 shows a system that recovered product from residues The system removed product continuously as an overhead product from column C1 The heavy residues were periodically removed from drum D1 Occasionally the temperature of drum D1 would rise to the point where the reboiler could no longer boil it The plant would then dump the drum content out of the bottom route B When the drum contents were dumped lots of lights were lost in the dump When the reboil ceased liquid from column C1 dumped and much of it ended in the D1 drum dump The problem was fixed by removing bottom residue streams continuously from both points A and B It took some trial and error to correctly set the bottom rate 28 Chapter 2 Where Fractionation Goes Wrong Figure 2 1 System that recovers product from residue CASE STUDY 2 5 INTERREBOILER DRIVES TOWER TO
43. er sal VLE model This model assumes that VLE is universal that is holds at every location between the total vapor flow and the total liquid flow In shell side conden sation the liquid and vapor are usually close to equilibrium locally when the liquid condenses on the tube surface But after the liquid drops off the tube and to the bottom of the shell there is not enough vapor liquid mixing to maintain equilibrium with the downstream vapor Thus there is usually local VLE at the tube surface but not universal VLE for the system This local equilibrium is responsible for the phenomena of subcooled refluxes coexisting with uncondensed vapor Condensers designed for total condensation have frequently been partial condensers because of local VLE Deviations from universal equilibrium can be large for condensers in series with broad boiling range mixtures Deviations are particularly high for mixtures with high light ends content and for arrangements where the liquid stays largely separated from the downstream vapor This case study represents an extreme example of these deviations For the overhead accumulator universal VLE requires that the operating pressure and the exiting liquid bubble point pressure be equal But bubble point pressure was half of the operating pressure If the entire exiting vapor flow had been absorbed into the naphtha stream the bubble point pressure would still have been less than the operating pressure So
44. er operated at its capacity limit It was to be debottlenecked for a 25 increase in capacity In addition it was required to handle several different feedstocks at high throughputs Due to the tight requirements thorough tests were conducted and formed the basis for a simulation which was used for the debottlenecking We have seen very few tests as extensive and thorough as the stabilizer tests Two tests were conducted a high reflux HR test and a low reflux LR test Simulation Versus Measurement With two seemingly minor and insignificant exceptions all reliable measurements compared extremely well with simulated values In most tests the accuracy and reliability of the data would have made it difficult to judge whether the exceptions were real or reflected a minor test data problem In this case however consistency checks verified that the exceptions were real The high accuracy and reliability of the test data made even small discrepancies visible and significant Case Study 1 12 Can You Name the Key Components 15 The discrepancies occurred in the HR test while the LR test showed no discrep ancy This was strange because the stabilizer was extremely steady and smooth during the HR test Any data problems should have occurred in the LR test or in both tests but not in the HR test alone The two exceptions were interlinked For the HR test the simulation predicted three times the measured Cs concentration in the stabilizer overhead
45. g several towers Case Study 1 1 Methanol in C3 Splitter Overhead 3 Background Methanol is often present in the C3 splitter feed in small concen trations usually originating from dosing upstream equipment to remove hydrates Hydrates are loose compounds of water and HCs that behave like ice and methanol is used like antifreeze The atmospheric boiling points of propylene propane and methanol are 54 44 and 148 F respectively The C3 splitters are large towers usually containing between 100 and 300 trays and operating at high reflux so they have lots of separation capability Problem Despite the large boiling point difference about 200 F and the large tower separation capability some methanol found its way to the overhead product in all these towers Very often there was a tight specification on methanol in the tower overhead Cause Methanol isa polar component which is repelled by the nonpolar HCs This repulsion is characterized by a high activity coefficient With the small concentration of methanol in the all HC tray liquid the repulsion is maximized that is the activity coefficient of methanol reaches its maximum infinite dilution value This high activ ity coefficient highly increases its volatility to the point that it almost counterbalances the much higher vapor pressure of propylene The methanol and propylene therefore become very difficult to separate Simulation All C splitter simulations that the author
46. gs 595 Reboilers That Did Not Work Number 9 on the Top 10 Malfunctions 596 23 1 Circulating Thermosiphon Reboilers 596 23 1 1 Excess Circulation 596 23 1 2 Insufficient Circulation 596 23 1 3 Insufficient AT Pinching 596 23 1 4 Surging 596 23 1 5 Velocities Too Low in Vertical Thermosiphons 597 23 1 6 Problems Unique to Horizontal Thermosiphons 597 23 2 Once Through Thermosiphon Reboilers 597 23 2 1 Leaking Draw Tray or Draw Pan 597 23 2 2 No Vaporization Thermosiphon 598 23 2 3 Slug Flow in Outlet Line 599 23 3 Forced Circulation Reboilers 599 23 4 Kettle Reboilers 599 23 4 1 Excess AP in Circuit 599 23 4 2 Poor Liquid Spread 601 23 4 3 Liquid Level above Overflow Baffle 602 24 25 s 23 5 23 6 23 7 23 8 23 9 24 1 24 2 24 3 24 4 24 5 24 6 24 7 24 8 25 1 25 2 25 3 25 4 25 5 25 6 25 7 Contents xix Internal Reboilers 602 Kettle and Thermosiphon Reboilers in Series 603 Side Reboilers 603 23 7 1 Inability to Start 603 23 7 2 Liquid Draw and Vapor Return Problems 603 23 7 3 Hydrates 603 23 7 4 Pinching 604 23 7 5 Control Issues 604 All Reboilers Boiling Side 604 23 8 1 Debris Deposits in Reboiler Lines 604 23 8 2 Undersizing 604 23 8 3 Film Boiling 604 All Reboilers Condensing Side 605 23 9 1 Non condensables in Heating Medium 605 23 9 2 Loss of Condensate Seal 605 23 9 3 Condensate Draining Problems 606 23 9 4 Vapor Steam Supply Bottleneck 606 Condensers That Did Not Work 607 Inerts
47. have been the perfect motivators for professional excellence and achievement Professor Ian Doig University of NSW who inspired me over the years showed me the practical side of distillation and guided me over a crisis early in my career Reno Zack who enthusiastically encouraged and inspired my achievements throughout my career at C F Braun Dick Harris and Trevor Whalley who taught me about practical distillation and encouraged my work and professional pursuits at ICI Australia and Jack Hull Tak Yanagi and Jim Gosnell who were sources of teaching and inspiration at C F Braun The list could go on and I express special thanks to all that encouraged inspired and contributed to my work over the years Much of my mentors teachings found their way into the following pages Special thanks are due to family members and close friends who have helped supported and encouraged my work my mother Dr Helen Kister my father Dr John Kister and Isabel Wu your help and inspiration illuminated my path over the years Last but not least special thanks are due to Mireille Grey and Stan Okimoto at Fluor who flawlessly and tirelessly converted my handwritten scrawl into a typed manuscript putting up with my endless changes and reformats H Z K xxvii This page intentionally left blank How to Use this Book The use of this book as a story book or bedtime reading is quite straight forward and needs no guidance Simply select the short s
48. iary Heat Exchanger Preheater Pumparound 576 20 3 Chemicals to from Other Equipment 577 20 3 1 Leaking from Tower 577 20 3 2 Leaking into Tower 577 20 3 3 Product to Product 578 20 4 Atmospheric 578 20 4 1 Chemicals to Atmosphere 578 20 4 2 Air into Tower 579 Relief and Failure 21 1 Relief Requirements 580 21 2 Controls That Affect Relief Requirements and Frequency 580 21 3 Relief Causes Tower Damage Shifts Deposits 581 xvii 563 571 575 580 xviii Contents 22 23 21 4 Overpressure Due to Component Entry 581 21 5 Relief Protection Absent or Inadequate 582 21 6 Line Ruptures 583 21 7 All Indication Lost When Instrument Tap Plugged 584 21 8 Trips Not Activating or Incorrectly Set 584 21 9 Pump Failure 585 21 10 Loss of Vacuum 585 21 11 Power Loss 585 Tray Packing and Tower Damage Part of Number 3 on the Top 10 Malfunctions 586 22 1 Vacuum 586 22 2 Insufficient Uplift Resistance 587 22 3 Uplift Due to Poor Tightening during Assembly 587 22 4 Uplift Due to Rapid Upward Gas Surge 589 22 5 Valves Popping Out 590 22 6 Downward Force on Trays 590 22 7 Trays below Feed Bent Up above Bent Down and Vice Versa 591 22 8 Downcomers Compressed Bowed Fallen 592 22 9 Uplift of Cartridge Trays 593 22 10 Flow Induced Vibrations 593 22 11 Compressor Surge 594 22 12 Packing Carryover 595 22 13 Melting Breakage of Plastic Packing 595 22 14 Damage to Ceramic Packing 595 22 15 Damage to Other Packin
49. ion In this case e g the C3 iC pair in the stabilizer extrapolation to other process conditions will be optimistic sometimes grossly so Based on the above it was concluded that the simulation was a reliable basis for debottlenecking for the base case similar feedstock to that used in one of the tests and for alternative feedstocks that are not widely different from the base case However for those cases of feedstock variations where feed composition varied widely from the base case the simulation could not be used with confidence until the inaccuracy in the C3 iC relative volatility was mitigated Postmortem The column was successfully debottlenecked The same simulation modified to account for the debottlenecking hardware modifications was found to give superb predictions of the post revamp performance CASE STUDY 1 13 LOCAL EQUILIBRIUM FOR CONDENSERS IN SERIES Contributed by W Randall Hollowell CITGO Lake Charles Louisiana This is my all time favorite fractionation simulation problem The entire refinery capacity was sometimes limited by the gas rate which was calculated to be zero Installation An atmospheric crude distillation tower had an extremely broad boil ing range overhead vapor with significant ethane high propane through full range kerosene There were three long double split flow condensers in series The shells were flange to flange and located directly above the overhead accumulator Problem Simulation
50. ions misleading flowmeter or composition One specific area of frequent mismatches be tween simulation and plant data is where there are two liquid phases Here com parison of measured to simulated temperature profiles is invaluable for finding the second liquid phase Another specific area of frequent mismatches is refinery vacuum towers Here the difficult measurement is the liquid entrainment from the flash zone into the wash bed which is often established by a component balance on metals or asphaltenes The key graphical techniques for troubleshooting simulations are the McCabe Thiele and Hengstebeck diagrams multicomponent distillation composition profiles and in azeotropic systems residue curve maps These techniques permit visualiza tion and insight into what the simulation is doing These diagrams are not drawn from scratch they are plots of the composition profiles obtained by the simulation using the format of one of these procedures The book by Stichlmair and Fair 472 is loaded with excellent examples of graphical techniques shedding light on tower operation In chemical towers reactions such as decomposition polymerization and hy drolysis are often unaccounted for by a simulation Also the chemistry of a process is not always well understood One of the best tools for getting a good simulation in these situations is to run the chemicals through a miniplant as recommended by Ruffert 417 In established processes such as
51. is improved GC data simulations agreed well with most of the pilot data The agreement between simulation and plant data was much better than before but was still not good This may have been due to poor plant data Specifically measured flash zone pressures were often bad Moral The analyses used for process simulations must be thoroughly understood CASE STUDY 1 10 MISLED BY ANALYSIS Contributed by Geert Hangx and Marleen Horsels DSM Research Geleen The Netherlands Problem After a product change in a multipurpose plant a light boiling by product could not be removed to the proper level in the batch distillation The concentration Case Study 1 11 Incorrect Feed Characterization Leads to Impossible Product Specifications of the light boiling component in the final product was 0 5 It should have been and was in previous runs 200 ppm Investigation The feed was analyzed by GC per normal procedure The con centration levels of different components looked good No significant deviation was found Then some changes in the distillation were performed such as increasing the lights fraction in the batch distillation e increasing the reflux ratio during the lights fraction and e decreasing the vapor load during the lights fraction These changes yielded no significant improvement The off specification product was redistilled The purity was improved but still the specification could not be met The GC analysis was check
52. lator hydraulic calculation led a plant to expect a capacity gain almost twice as high as the tower revamp actually achieved History A refinery vacuum tower was debottlenecked for a 30 capacity gain by replacing 2 in Pall rings in the wash and heavy vacuum gas oil HVGO sections with 3 in modern proprietary random packings Only about 15 20 capacity gain was achieved It was theorized that above this throughput vapor maldistribution set in Case Study 1 14 Simulator Hydraulic Predictions To Trust or Not to Trust 21 and caused the tower to lose separation The refinery sought improvements to vapor distribution in an effort to gain the missing 10 15 Troubleshooting A vacuum manometer pressure survey showed that at the point where the tower lost separation the pressure drop was 0 65 in H20 ft packing Based on air water measurements many suppliers packages take the capacity limit or flood point to occur at a pressure drop of 1 5 2 in HO ft packing Work by Strigle 473 Rukovena and Koshy 418 and Kister and Gill 257 259 demonstrated that such numbers are grossly optimistic for modern high capacity random and structured packings Using published flood data Kister and Gill 257 259 showed that for random and structured packings the flood pressure drop is given by AP hood 0 115 F87 1 where AProoa is the flood pressure drop in H O ft packing and Fp is the packing factor ft This equation was shown to give a good
53. lighter in vapor 0 4 0 6 0 8 1 Mole fraction nC and lighter in liquid Mole fraction nC and lighter in vapor 0 3 0 5 0 7 0 9 Mole fraction nC and lighter in liquid c Figure 1 3 Hengstebeck diagrams for stabilizer tests a C3 iC4 separation HR test b Ca iCs separation HR test c nC4 iCs separation LR test From Ref 254 Reproduced with permission Copyright 1995 AIChE All rights reserved Case Study 1 12 Can You Name the Key Components 17 In the LR test the Hengstebeck diagrams for the C3 iC4 and iC4 nC separation were similar to those for the HR test Fig 1 3a In this test too the stabilizer stripping section effectively separated C and lighter from iC4 and heavier and iC and lighter from nC and heavier Figure 1 3c indicates that in the LR test above the feed the separation of nC and lighter from iCs and heavier was pinched This is different from the HR test where the rectifying section effectively separated nC and lighter from iCs and heavier The diagram also shows that as in the HR test the nC4 iC5 separation was pinched in the stripping section Overall the stabilizer behavior in the LR test resembled that of HR test with the exception that the rectifying section which separated nC from iCs in the HR test was pinched and did little of this separation in the LR test Why the Differences Between Measurement and Simulation There were two conceivable explanations to the high C
54. lution A model was developed to more closely represent the condensation steps Liquid condensed in each shell was assumed to be in equilibrium with the gas leaving that shell After the liquid left the shell in which it condensed it was assumed to have zero mass transfer with the gas phase but to be cooled to the local operating temperature This model had only one third of the total liquid the one third that condensed in the last shell in equilibrium with the off gas The other two thirds of the liquid was much heavier and caused the overall liquid bubble point pressure to be about half that of the liquid that condensed in the last shell The actual system was 20 Chapter 1 Troubleshooting Distillation Simulations more complex than the above model in particular The liquid condensed in each shell was heavier than the calculated liquid in equilibrium with the exiting vapor Liquid condensed in an upstream shell experienced a moderate amount of mixing and thus mass transfer with downstream vapor The above two effects are in opposite directions and largely cancel each other for this case study perhaps because of the double split arrangement and three shells in series This cancellation of errors caused the model to adequately match actual liquid composition and actual vapor rate leaving the overhead accumulator Morals For broad boiling range mixtures condensers particularly condensers in series have less capacity than estimated by c
55. n say by a supplier or an independent method is a good idea When Distillation Design 251 was compiled special effort was made to talk to authors of good correlations with the objective of exploring their limitations and filling in the missing blanks For instance the pressure ranges for the application of Smith s correlation were listed in Distillation Design almost two years before the above letter was written Chapter 2 Where Fractionation Goes Wrong Fractioination issues featured very low on the distillation malfunctions list for the last half century 255 Only two issues rated a mention intermediate component accumulation and two liquid phases Neither of these made it to the top 20 distillation malfunctions This contrasts the author s experience Intermediate component accu mulation is experienced frequently enough to justify a place in the top 20 maybe even close to the 10th spot The large number of cases of intermediate component accumu lation reported in this book will testify to that In many cases the accumulation led to periodic flooding in the tower Other problems induced by the accumulation include corrosion product losses product contamination and inability to draw a product stream A second liquid phase either present where undesirable or absent where desired was troublesome in several case histories most from chemical towers In many cases issues in the overhead decanter or its piping induced an undesir
56. n before the modification the condenser behaved as a total condenser from the product residue separation viewpoint product was withdrawn as liquid and had therefore contributed little to the product residue separation Another Plant A glycol residue tower in a completely different plant and operated by a different company experienced a somewhat similar problem In that case the amount of water was small Instead of escaping in the inerts route the water was condensed and refluxed back into the tower Over a period of time water built up in the overhead loop and adversely affected product purity The problem was solved by periodically running the reflux drum liquid to a flash tank CASE STUDY 2 8 COMPOSITION PROFILE PLOT TROUBLESHOOTS MULTICOMPONENT SEPARATION Henry Z Kister Rusty Rhoad and Kimberly A Hoyt references 254 273 Reproduced with permission Copyright 1996 AIChE All rights reserved Engineers seldom bother plotting composition profiles in multicomponent distillation Like the McCabe Thiele and Hengstebeck diagrams column composition profiles generated from the compositions calculated by the simulation Refs 243 and 251 have detailed examples are a superb analytical and troubleshooting tool that provides vi sualization that simulations do not Undetected abnormalities often reveal themselves as a column malfunction after start up This case shows how a composition profile identified a very unforgiving column design
57. n or by theory In addition to the lack of credibility of Smith s values the correlation of Jones used as the basis of the Smith method appears inaccurate for the high pressure systems For these reasons I would not recommend use of the Evertrue Smith correlation regardless of the system pressure for predicting whether or not a packed tower will work Instead the 1960 correlation included on Evertrue should be used This correlation is based on well known methods and can be found in Perry s Handbook It predicts the tower would be at 96 percent of flood compared to the 106 percent predicted by the vendor which is much closer than the Smith correlation In either case calculations must be verified by the packing vendor I recommend that the vendor verifies the results even for estimates What Really Happened In our experience both the Smith and the Jones correla tions are excellent The correlation that leaves a lot to be desired for modern packing calculations is the 1960 one Nevertheless the letter s author appeared to have reached the converse conclusion It is a sad fact of life that correlation authors always examine their correlations for good statistical fit but seldom properly explore and clearly define their correlation limitations On page 39 of Ref 259 Kister and Gill remark An excellent fit to experimental data is insufficient to render a packing pressure drop correlation suitable for design In addition the
58. oning and Abnormal Operation Number 4 on the Top 10 Malfunctions 499 13 12 1 Blinding Unblinding Lines 499 12 2 Backflow 500 12 3 Dead Pocket Accumulation and Release of Trapped Materials 501 12 4 Purging 501 12 5 Pressuring and Depressuring 502 12 6 Washing 502 12 7 On Line Washes 504 12 8 Steam and Water Operations 506 12 9 Overheating 506 12 10 Cooling 507 12 11 Overchilling 507 12 12 Water Removal 508 12 12 1 Draining at Low Points 508 12 12 2 Oil Circulation 508 12 12 3 Condensation of Steam Purges 508 12 12 4 Dehydration by Other Procedures 508 12 13 Start Up and Initial Operation 509 12 13 1 Total Reflux Operation 509 12 13 2 Adding Components That Smooth Start Up 509 12 13 3 Siphoning 509 12 13 4 Pressure Control at Start Up 510 12 14 Confined Space and Manhole Hazards 510 Water Induced Pressure Surges Part of Number 3 on the Top 10 Malfunctions 512 14 13 1 Water in Feed and Slop 512 13 2 Accumulated Water in Transfer Line to Tower and in Heater Passes 513 13 3 Water Accumulation in Dead Pockets 513 13 4 Water Pockets in Pump or Spare Pump Lines 514 13 5 Undrained Stripping Steam Lines 515 13 6 Condensed Steam or Refluxed Water Reaching Hot Section 516 13 7 Oil Entering Water Filled Region 517 Explosions Fires and Chemical Releases Number 10 on the Top 10 Malfunctions 518 14 1 Explosions Due to Decomposition Reactions 518 14 1 1 Ethylene Oxide Towers 518 14 1 2 Peroxide Towers 519 14 1 3 Nitro Compound
59. onventional simulation with universal VLE This is a failure in simulation and design rather than an equipment failure A simulation based upon good operating data can often be used to adequately model the effect of local equilibrium Good heat and material balances and confidence in them are necessary to step away from universal VLE assumptions and obtain realistic simulations Process designers have compensated for their lack of understanding by using large design margins for condensers by specifying off gas compressors for zero calculated gas rates and by greatly oversizing off gas compressors These practices can still result in lack of capacity for installations such as in this case study Even very rough estimates of local equilibrium effects can be far better than conventional calculations for series condensation For a single shell and moderate deviations from universal VLE a reasonable sub cooling delta temperature can sometimes be used for simulation and design In extreme cases calculations for zones in each shell may be necessary to give good simulation or design For this case study the zone method would probably have been required if the condenser paths had been many times longer than in a double split flow configuration CASE STUDY 1 14 SIMULATOR HYDRAULIC PREDICTIONS TO TRUST OR NOT TO TRUST Henry Z Kister reference 254 Reproduced with permission Copyright 1995 AIChE All rights reserved In this case study a simu
60. oratory as well 13 14 Chapter Troubleshooting Distillation Simulations as an impartial third party laboratory consistently showed about 1 0 of Cg s in the distillate Increasing reflux ratio or other operation adjustments did not improve distillate purity Troubleshooting The tower was shut down after about 6 weeks of operation to inspect the trays No damage was found and the trays were reported to be cleaner than new The design simulation was rerun with a variety of options correlations con vergence criteria and plant analysis data The laboratory methods which were es tablished American Society for Testing and Materials ASTM test methods were reviewed It became apparent that the feed contained some low boiling compo nents such as certain methyl cyclo Cs s which were analyzed correctly as C s but whose boiling points are in the Cs range Since these components would end up in the distillate it was thermodynamically impossible to achieve the specified performance Solution The higher impurity level could be lived with without excessive economic penalty and was accepted Moral Correct characterization of feed components is essential even for an ideal hydrocarbon mixture CASE STUDY 1 12 CAN YOU NAME THE KEY COMPONENTS Henry Z Kister reference 254 Reproduced with permission Copyright 1995 AIChE All rights reserved Installation A stabilizer separating C3 and lighter HCs from nC4 and heavi
61. oting this type of simulation problems Distillation Simulation A sequence of distillation columns for separation of a mixture containing water and several organic alcohols was set up in a simulator Since some of the alcohols are not fully miscible with water a nonrandom two liquid NRTL model was selected to model VLLE in the system At atmospheric pressure the vapor phase was treated as an ideal gas Problem Simulation of the sequence of distillation columns never converged giv ing many warnings about flash failures Investigation For the three key components methanol water and n butanol a phase diagram was created 508 Fig 1 1a As expected the water methanol and methanol n butanol edges are homogeneous and the water n butanol edge contained animmiscibility gap Surprisingly the three liquid region and three two liquid regions covered almost the entire composition space Since water and methanol as well as butanol and methanol are fully miscible the diagram should have been dominated by a single liquid region Just looking at the phase diagram one can conclude that the model is not correct Analysis Binary interaction parameters for activity models used for VLLE cal culations are published for thousands of components see e g DECHEMA 158 series They are regressed based on various experimental data and usually fit the experimental points quite well NRTL UNIQUAC and Wilson models extend these binary data to multicom
62. ource 2 40 feed 0 5LK Interreboiler and A lower feed A7 Mole fraction of light component in vapor 0 3 0 4 0 5 0 6 0 7 Mole fraction of light component in liquid b Figure 2 2 Proposed C2 splitter debottleneck a proposed changes adding an interreboiler and splitting the feeds b McCabe Thiele diagram that clearly warned of imminent pinch From Ref 254 276 Reproduced with permission Copyright 1995 AIChE All rights reserved 30 Chapter 2 Where Fractionation Goes Wrong Hydraulic calculations showed that the rectifying section would be barely capable of handling the increased throughput The stripping section was undersized for the higher throughput and would require an expensive retray with specialty high capacity trays Alternative Scheme A clever alternative scheme was conceived with a potential of slashing the revamp costs as well as saving energy There was scope to have the feed enter as two separate streams One contained 70 ethylene made up 60 of the feed and was to enter on tray 55 Fig 2 2a The second contained 50 ethylene made up 40 of the feed and was to enter on tray 45 To unload the bottom section an interreboiler was to be added at tray 46 supplying about 10 of the total column heat duty Since the interreboiler was to convert 10 of the liquid into vapor the vapor and liquid traffic in the narrow diameter section below would diminish by 10 This unloading was enough to accommodate the po
63. ped with random packing with a packing factor of 18 This column would rapidly lose efficiency when the pressure drop in creased above 0 67 in H2O ft packing This compares to a flood pressure drop of 0 87 from Equation 1 The measurement was slightly lower than the prediction because the vapor load varied through the packings so much of the bed operated at lower pressure drop Simulation prediction both vendor and general options predicted a much higher capacity Similar to Case Study 1 14 the plant initially theorized that the shortfall in capacity was due to vapor maldistribution Tower C This was a chemical absorber equipped with random packing with a packing factor of 18 The highest pressure drop at which operation was stable was 0 8 in H O ft packing Above this the pressure drop would rapidly rise This compares to a flood pressure drop of 0 87 from Equation 1 Simulation predictions both vendor and general options were of a 20 higher capacity Tower D Random packing installed in a chemical tower fell short of achieving design capacity The vendor method predicted flooding at a pressure drop of 1 5 in H O ft packing With a packing factor of 18 Equation 1 predicted that the packing would flood much earlier at a pressure drop of 0 8 in H2O ft packing The packing flooded at exactly that pressure drop CASE STUDY 1 16 DO GOOD CORRELATIONS MAKE THE SIMULATION HYDRAULIC CALCULATIONS RELIABLE Henry Z Kister reference 254 Reprod
64. plosion databases and computerized searches finding the appropriate information in due time has be come like finding a needle in an evergrowing haystack To locate a useful reference one needs to click away a huge volume of wayward leads Further cost cutting mea sures led to library closures and to curtailed circulation and availability of some prime sources of information such as AIChE meeting papers The purpose of this book is pick the needles out of the haystack The book collects lessons from past experiences and puts them in the hands of troubleshooters in a usable form The book is made up of two parts the first is a collection of war stories with the detailed problems and solutions The second part is a database mega table which presents summaries of all the war stories I managed to find in the literature The summaries include some key distillation related morals For each of these the literature reference is described fully so readers can seek more details Many of the case histories could be described under more than one heading so extensive cross references have been included If an incident that happened in your plant is described you may notice that some details could have changed Sometimes this was done to make it more difficult for people to tell where the incident occurred At other times this was done to simplify the story without affecting the key lessons Sometimes the incident was written up several yea
65. ponent systems without requiring additional ternary quater nary and so on interaction parameters That is why these models are so popular for modeling VLE for strongly nonideal azeotropic mixtures This extension however is not always performed correctly by the model For the ternary mixture methanol water n butanol the binary interaction pa rameters have been taken from DECHEMA 158 Some of them are recommended values All of them describe all the binary pairs very well But what they predict when combined together can be seen in Figure 1 1a Notice that to create this VLLE diagram an extremely robust flash calculation with stability test is essential Without a reliable global stability test flash calculation can easily fail at some points in this component space or give unstable solutions 526 Case Study 1 5 Modeling Ternary Mixture Using Binary Interaction Parameters 7 Water 1 0 N 0 0 0 2 0 4 0 6 0 8 1 0 n Butanol Methanol a Water TEN IL NN lll moa ras eke N wo liquid region Three liquid region 0 8 Vapor tine 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 0 1 0 3 0 5 0 7 0 9 0 0 0 2 0 4 0 6 0 8 1 0 n Butano Methanol b Figure 1 1 Phase diagram for nonideal system methanol water n butanol based on extension of good binary data using NRTL model a incorrect extension b correct extension 8 Chapter 1 Troubleshooting Distillation Simulations Solution Another se
66. predicted a zero off gas rate at peak summer temperatures But actual off gas rates were substantial even in winter Summer crude charge rate was sometimes reduced to avoid flaring of gas in excess of compressor capacity There was a strong economic incentive to increase butane spiking of crude but this was not done due to concerns that the gas rate would increase Case Study 1 13 Local Equilibrium For Condensers in Series 19 Component Balances Earlier calculations had failed to obtain an adequate ma terial balance of the lightest components in the overhead The naphtha GC analyses were found to be poor Procedures were corrected by the laboratory and good material balance closures were obtained Simulations predicted that all of the exiting vapor off gas should have been ab sorbed into the naphtha stream at the operating temperature and pressure The naphtha had much lower light ends concentrations than predicted 3090 of the predicted for propane 50 for butanes and 75 for pentanes concentration These low concen trations in the naphtha provided the vapor off gas flow With many sets of data each giving good material balance closure it was obvious that the vapor exiting the overhead accumulator was not in equilibrium with liquid exiting the accumulator Condensers fouled severely on the tube side but this did not explain the large deviations from equilibrium Theory Conventional process simulation assumes what can be called the univ
67. quid side draw below the pasteurization trays The side draw may be stripped to further reduce light ends The vent gas may be refrigerated and solvent washed or otherwise treated to reduce loss of desired product Solution An accurate specific correlation outside of the process simulation pack age was used to calculate HS and CO concentration in the methanol water tower feed Solubility of HC components was roughly estimated because they were at rela tively low concentrations in the tower feed A high performance coalescer was used to minimize liquid HC droplets in the tower feed A pasteurization section was added to the top of the tower The overhead vent gas purge stream was designed to remove most of the H2S CO and light HCs Downstream recovery of methanol from the vent gas and stripping of the methanol product side draw were considered but found to be uneconomical 6 Chapter Troubleshooting Distillation Simulations Moral Poor simulation and design result from poor selection of VLE and VLLE methods Computer output does not include a warning when the selected VLE method produces garbage CASE STUDY 1 5 MODELING TERNARY MIXTURE USING BINARY INTERACTION PARAMETERS Contributed by Stanislaw K Wasylkiewicz Aspen Technology Inc Calgary Alberta Canada This case study describes a frequently encountered modeling problem during sim ulation of heterogeneous azeotropic distillation Phase diagrams are invaluable for troublesho
68. r 3 on the Top 10 Malfunctions Reboilers That Did Not Work Number 9 on the Top 10 Malfunctions Condensers That Did Not Work Misleading Measurements Number 8 on the Top 10 Malfunctions 193 215 225 233 237 241 253 257 271 281 287 291 315 335 347 Contents 26 Control System Assembly Difficulties 27 Where Do Temperature and Composition Controls Go Wrong 28 Misbehaved Pressure Condenser Reboiler and Preheater Controls 29 Miscellaneous Control Problems DISTILLATION TROUBLESHOOTING DATABASE OF PUBLISHED CASE HISTORIES 1 Troubleshooting Distillation Simulations 1 1 VLE 398 1 1 1 Close Boiling Systems 398 1 1 2 Nonideal Systems 399 1 1 3 Nonideality Predicted in Ideal System 400 1 1 4 Nonideal VLE Extrapolated to Pure Products 400 1 1 5 Nonideal VLE Extrapolated to Different Pressures 401 1 1 6 Incorrect Accounting for Association Gives Wild Predictions 401 1 1 7 Poor Characterization of Petroleum Fractions 402 1 2 Chemistry Process Sequence 402 1 3 Does Your Distillation Simulation Reflect the Real World 404 1 3 1 General 404 1 3 2 With Second Liquid Phase 406 1 3 3 Refinery Vacuum Tower Wash Sections 406 1 3 4 Modeling Tower Feed 406 1 3 5 Simulation Plant Data Mismatch Can Be Due to an Unexpected Internal Leak 406 1 3 6 Simulation Plant Data Mismatch Can Be Due to Liquid Entrainment in Vapor Draw 407 1 3 7 Bug in Simulation 407 1 4 Graphical Techniques to Troubleshoot Simula
69. rigeration gas plant Fig 2 3a This still was the last step of purification of the absorption oil before the oil was returned to the plant absorber to absorb heavy components from natural gas Feed to the still was the absorption oil containing the absorbed gasolines and some LPG Lighter components were removed from the oil upstream of the still Lean oil left lighter to storage 525 550 F Lean oil bottoms a A Operation B Design Column overhead temperature F 10 15 50 Reflux flow gpm b Figure 2 3 Multicomponent still that showed temperature multiciplity a lean oil still b variation of lean oil still top temperature with reflux From Ref 263 Reproduced with permission Copyright 1987 AIChE All rights reserved 32 Chapter2 Where Fractionation Goes Wrong as the still bottom product while gasoline and LPG were the top product The still operated at 210 psig Note the large temperature difference between the bottom and top of the still The main objective of the still was to keep gasoline out of the column bottom This was achieved by the furnace outlet temperature control The reflux rate was trimmed by manually adjusting the flow controller set point so as to give a reasonably constant column overhead temperature The reflux drum was flooded and liquid level in the condenser was used to control column pressure Problem The plant absorber appeared to be malfunctioning It did not
70. rs after it occurred and memories of some details faded away Sometimes and this is the most likely reason the case history did not happen in your plant at all Another plant had a similar incident The case histories and lessons drawn are described to the best of my and the contributors knowledge and in good faith but do not always correctly reflect the problems and solutions Many times I thought I knew the answer possibly even solved the problem only to be humbled by new light or another experience later The experiences and lessons in the book are not meant to be followed blindly They are meant to be taken as stories told in good faith and to the best of knowledge and understanding of the author or contributor We welcome any comments that either affirm or challenge our perception and understanding If you picked the book you expressed interest in learning from past experiences This learning is an essential major step along the path traveled by a good troubleshooter or designer Should you select this path be prepared for many sleepless nights in the plant endless worries as to whether you have the right answer tests that will Preface XXV shatter your favorite theories and many humbling experiences Yet you will share the glory when your fix or design solves a problem where others failed You will enjoy harnessing the forces of nature into a beneficial purpose Last but not least you will experience the electric excitement of th
71. s 543 16 1 2 Corrosion and Fouling Inhibitors Additives and Impurities 544 16 1 3 Hydrocarbon Condensation into Aqueous Solutions 545 16 1 4 Wrong Filter Elements 546 16 1 5 Rapid Pressure Reduction 546 16 1 6 Proximity to Solution Plait Point 546 xvi Contents 16 2 16 3 16 4 16 5 16 6 What Are Foams Sensitive To 546 16 2 1 Feedstock 546 16 2 2 Temperature 547 16 2 3 Pressure 547 Laboratory Tests 547 16 3 1 Sample Shake Air Bubbling 547 16 3 2 Oldershaw Column 547 16 3 3 Foam Test Apparatus 548 16 3 4 At Plant Conditions 548 Antifoam Injection 548 16 4 1 Effective Only at the Correct Quantity Concentration 548 16 4 2 Some Antifoams Are More Effective Than Others 549 16 4 3 Batch Injection Often Works But Continuous Can Be Better 549 16 4 4 Correct Dispersal Is Important Too 550 16 4 5 Antifoam Is Sometimes Adsorbed on Carbon Beds 550 16 4 6 Other Successful Antifoam Experiences 550 16 4 7 Sometimes Antifoam Is Less Effective 551 System Cleanup Mitigates Foaming 551 16 5 1 Improving Filtration 551 16 5 2 Carbon Beds Mitigate Foaming But Can Adsorb Antifoam 553 16 5 3 Removing Hydrocarbons from Aqueous Solvents 553 16 5 4 Changing Absorber Solvent 553 16 5 5 Other Contaminant Removal Techniques 554 Hardware Changes Can Debottleneck Foaming Towers 555 16 6 1 Larger Downcomers 555 16 6 2 Smaller Downcomer Backup Lower Pressure Drop Larger Clearances 556 16 6 3 More Tray Spacing 556 16 6 4 Removing Top Two Trays Does
72. s concentration in the HR test simu lation 1 Inaccuracies in VLE data Detailed checks of the VLE confirmed that the values used were very good and superior to those predicted by the commercial simulator program but not perfect Two relevant inaccuracies were a high C3 iC4 volatility prediction for the stripping section and a low C4 Cs volatility prediction for the rectifying section N Efficiency differences between different binary pairs This explanation was unlikely because the simulation would suggest a considerably higher effi ciency for the higher volatility pair nC4 iCs than for the lower volatility pair iC4 nC4 In contrast test data 52 379 381 show that lower volatility pairs have a higher efficiency It was therefore concluded that VLE inaccuracy is the most likely explanation One unanswered question is why the differences between measurement and simu lation were observed only in the HR test and not in the LR test Again the Hengstebeck diagrams provided the answer For the HR test the Hengstebeck diagram Fig 1 3b shows that the rectifying section rectifies Cs from the nC4 and lighter Any error in the relative volatility of the nC 4liCs and nC4 nCs pairs is magnified at each separation stage The final result is a large difference between measured and simulated top product compositions For the LR test the Hengstebeck diagram Fig 1 3c shows very little separation of nC from Cs in the rectifying section Bec
73. shooting Distillation Simulations In one refinery and one petrochemical debutanizer mercury compounds with boiling points in the gasoline range were found in the LPG probably reaching it by a similar mechanism CASE STUDY 1 2 WATER IN DEBUTANIZER QUO VADIS Installation A debutanizer separating C4 HCs from HCs in the Cs Cg range Feed to the tower was partially vaporized in an upstream feed bottom interchanger The feed contained a small amount of water Water has a low solubility in the HCs and distilled up The reflux drum was equipped with a boot designed to gravity separate water from the reflux Problem When the feed contained a higher concentration of water or the reflux boot was inadvertently overfilled water was seen in the tower bottoms Cause The tower feed often contained caustic Caustic deposits were found in the tower at shutdown Sampling the water in the tower bottom showed a high pH Anal ysis showed that the water in the bottom was actually concentrated caustic solution Prevention Good coalescing of water and closely watching the interface level in the reflux drum boot kept water out of the feed and reflux Maximizing feed preheat kept water in the vapor CASE STUDY 1 3 BEWARE OF HIGH HYDROCARBON VOLATILITIES IN WASTEWATER SYSTEMS Benzene was present in small concentration of the order of ppm ina refinery wastewa ter sewer system Due to the high repulsion between the water and benzene molecules benzene has
74. st debottleneck throughput In principle the interreboiler was to unload the narrow diameter section that bottlenecked the tower Splitting the feed was to assist in expanding the stripping section from 45 to 55 trays without adversely affecting separation in the rectifying section The extra stripping trays were needed to accommodate for the lower V B stripping ratio generated below the interreboiler A computer simulation showed that the scheme would work well There were no convergence problems nor was there anything about the simulation that may indicate a potential problem The scheme received the go ahead Just prior to going into the final design a McCabe Thiele diagram was con structed to explore hidden traps Fig 2 2 The pinch just below the interreboiler was glaring Postmortem The interreboiler caused the V B for the section below to diminish almost to the minimum stripping Although hydraulically the interreboiler would have fulfilled its function the column may not have achieved the design separation due to the pinch Alternatively to overcome the pinch the operator would have needed to raise both the reflux and reboil and would have possibly encountered a hydraulic bottleneck CASE STUDY 2 6 TEMPERATURE MULTIPLICITY IN MULTICOMPONENT DISTILLATION Henry Z Kister and Tom C Hower reference 263 Reproduced with permission Copyright 1987 AIChE All rights reserved Installation A lean oil still in an absorption ref
75. stillation profile away from the binary pinch toward the minimum boiling heterogeneous azeotrope A decanter can then be used to obtain required distillate purity in far fewer stages than in the original binary distillation 525 Distillation Simulation A column with top decanter was set up in a simulator to remove water from a mixture containing mostly water and acetic acid N Butyl acetate was selected as an entrainer The vapor phase was treated as an ideal gas Idel 227 option For the liquid phase the NRTL model was selected Problem Even with an extreme reflux and a large number of stages the simulation never achieved the required high purity water in the bottom product of the column Troubleshooting For the three key components water acetic acid and the en trainer a distillation region diagram DRD was created 227 to examine the three component space for multiple liquid regions azeotropes and distillation boundaries as shown in Figure 1 24 10 Chapter 1 Troubleshooting Distillation Simulations Azeotropes Vapor line Liquid Hiquid region Distillation boundaries 0 1 0 3 0 5 0 7 0 9 0 0 0 2 0 4 0 6 0 8 1 0 n B C2 oate a Acetic acid 0 2 e lt 00 02 0 4 0 6 08 10 n B C2 oate b Acetic acid Figure 1 2 Phase diagram for dehydration of acetic acid using n butyl acetate n B C2 oate entrainer at I atm a with ideal vapor phase incorrect b
76. t of binary interaction parameters was carefully selected and a new phase diagram was recreated 34 The VLLE changed dramatically Fig 1 12 There is no more three liquid phase region and only one two liquid phase region covers only a small part of the composition space After proper selection of interaction parameters of the thermodynamic model the sequence of distillation columns converged quickly without any problems Morals To simulate multicomponent nonideal distillation the behavior of the mixture must be carefully verified starting from binary mixtures then ternary subsys tems and so on Since there may be many pairs of binary interaction parameters of an activity thermodynamic model that describe behavior of a binary mixture equally well it is recommended to select one with the lowest absolute values It is our experience that such values extrapolate better to multicomponent mixtures To correctly create a multicomponent nonideal VLLE model an extremely robust VLLE calculation routine with a reliable global stability test is a must even if liquid liquid LL split is not expected Because of their visualization capabilities VLLE phase diagrams are invalu able for ternary and quaternary mixtures for verification of thermodynamic models used in distillation simulations CASE STUDY 1 6 VERY LOW CONCENTRATIONS REQUIRE EXTRA CARE IN VLE SELECTION Contributed by W Randall Hollowell CITGO Lake Charles Louisiana
77. this UNIQAC equation Postmortem Exceptions to the typical choices of chemical VLE methods are of ten not reflected in process simulation packages For this case the same data base was probably used by all of the process simulation packages for the regression of UNIQUAC parameters Predicting VLE for high purity mixture often requires ex trapolation of activity coefficients Only one method and one simulation package did a good extrapolation to the low methanol end Cross checking of VLE equations and packages is a useful way to identify potential problems CASE STUDY 1 7 DIAGRAMS TROUBLESHOOT ACETIC ACID DEHYDRATION SIMULATION Contributed by Stanislaw K Wasylkiewicz Aspen Technology Inc Calgary Alberta Canada This case study describes a typical thermodynamic modeling problem in distillation simulation and an application of residue curve maps for troubleshooting and proper model selection The problem described here happened far too many times for many of our clients Dehydration of Acetic Acid At atmospheric pressure there is no azeotrope in the binary mixture of water and acetic acid However there is a tangent pinch close to pure water This makes this binary separation very expensive if only a small concentration of acetic acid in water is allowed high reflux many rectifying stages The difficult separation caused by the tangent pinch can be avoided by adding an entrainer that forms a new heterogeneous azeotrope moving the di
78. tions 407 1 4 1 McCabe Thiele and Hengstebeck Diagrams 407 1 4 2 Multicomponent Composition Profiles 407 1 4 3 Residue Curve Maps 407 1 5 How Good Is Your Efficiency Estimate 407 1 6 Simulator Hydraulic Predictions To Trust or Not to Trust 409 1 6 1 Do Your Vapor and Liquid Loadings Correctly Reflect Subcool Superheat and Pumparounds 409 1 6 2 How Good Are the Simulation Hydraulic Prediction Correlations 409 ix 357 373 377 395 398 x Contents 2 Where Fractionation Goes Wrong 410 2 5 2 6 Insufficient Reflux or Stages Pinches 410 No Stripping in Stripper 412 Unique Features of Multicomponent Distillation 412 Accumulation and Hiccups 413 2 4 1 Intermediate Component No Hiccups 413 2 4 2 Intermediate Component with Hiccups 414 2 4 3 Lights Accumulation 416 2 4 4 Accumulation between Feed and Top or Feed and Bottom 417 2 4 5 Accumulation by Recycling 418 2 4 6 Hydrates Freeze Ups 418 Two Liquid Phases 419 Azeotropic and Extractive Distillation 421 2 6 1 Problems Unique to Azeotroping 421 2 6 2 Problems Unique to Extractive Distillation 423 3 Energy Savings and Thermal Effects 424 3 1 3 2 Energy Saving Designs and Operation 424 3 1 1 Excess Preheat and Precool 424 3 1 2 Side Reboiler Problems 424 3 1 3 Bypassing a Feed around the Tower 424 3 1 4 Reducing Recycle 425 3 1 5 Heat Integration Imbalances 426 Subcooling How It Impacts Towers 428 3 2 1 Additional Internal Condensation and Reflux 428
79. tleneck this time by others went sour at the same unit The tower I previously struggled with was replaced by a larger one but the next tower in the sequence almost the same hydraulics as the first was debottlenecked by increasing tray hole areas It dawned on me how short a memory the process industries have People move on the lessons get forgotten and the same mistakes are repeated It took only one decade to forget Indeed people moved on only one person beside me that experienced the 1980s debottleneck was involved in the 1990s efforts This person actually questioned xxiii xxiv Preface the debottleneck proposal but was overruled by those who did not believe it will happen again Likewise many experiences are repeatedly reported in the literature Over the last two decades there has been about one published case history per year of a tower flooding prematurely due to liquid level rising above the reboiler return nozzle or of a kettle reboiler bottleneck due to an incorrectly compiled force balance One would think that had we learned from the first case all the repetitions could have been avoided And again for every case that is reported there are tens maybe hundreds that are not Why are we failing to learn from past lessons Mergers and cost cuts have retired many of the experienced troubleshooters and thinly spread the others The literature offers little to bridge the experience gap In the era of information ex
80. tories of specific interest and read them More challenging is the use of this book to look for experiences that could have relevance to a given troubleshooting endeavor Here the database mega Table in the second part of the book is the key Find the appropriate subject matter via the table of contents or index and then explore the various summaries including those in the cross references The database mega Table also lists any case histories that are described in full in this book Such case histories will be prefixed DT acronym for Distillation Troubleshooting For instance if the mega Table lists DT2 4 it means that the full experience is reported as case history 2 4 in this book The database as well as many of the case histories list only some of the key lessons drawn The lessons listed are not comprehensive and omit nondistillation morals such as the needs for more staffing or better training The reader is encouraged to review the original reference for additional valuable lessons For quick reference the acronyms used in Distillation Troubleshooting are listed up front and the literature references are listed alphabetically Some of the case histories use English units others use metric units The units used often reflect the unit system used in doing the work The conversions are straight forward and can readily be performed by using the conversion tables in Perry s Hand book 393 or other handbooks The author will be
81. trategies contained herein may not be suitable for your situation You should consult with a professional where appropriate Neither the publisher nor author shall be liable for any loss of profit or any other commercial damages including but not limited to special incidental consequential or other damages For general information on our other products and services please contact our Customer Care Department within the U S at 800 762 2974 outside the U S at 317 572 3993 or fax 317 572 4002 Wiley also publishes its books in a variety of electronic formats Some content that appears in print may not be available in electronic format For more information about Wiley products visit out web site at www wiley com Library of Congress Cataloging in Publication Data Kister Henry Z Distillation troubleshooting Henry Z Kister p cm Includes bibliographical references ISBN 13 978 0 0471 46744 1 Cloth ISBN 10 0 471 46744 8 Cloth 1 Distillation apparatus Maintenance and repair I Title TP159 D9K57 2005 660 28425 dc22 2004016490 Printed in the United States of America o 9 8 7 6 5 To my son Abraham and my wife Susana who have been my love inspiration and the lighthouses illuminating my path and to my life long mentor Dr Walter Stupin it is easy to rise when carried on the shoulders of giants This page intentionally left blank Contents Preface xxiii Acknowledgments xxvii How to Use this Book
82. tudy 4 9 were performed and showed that the tower operated well below flood and that both the pressure drop and flood point were well inline with predictions Gamma scans verified that distribution below the flood point was quite reasonable and there were no signs of plugging Likely Cause During the troubleshooting the design simulation was revisited and the composition profiles plotted The profiles plot the concentrations of each component in the liquid one plot and the vapor a second plot against the theoretical stage number Figure 2 5 is a condensed version singling out the IK in the liquid and the HK in the vapor These were the prime actors in the current problem The diagram shows an extremely steep peak for the HK in the vapor Stage 18 vapor contains 5590 HK By the time the vapor draw off is reached on stage 13 five stages up the HK concentration is supposed to drop to 1 On stage 14 the HK concentration is about 7 and on stage 15 it is 18 Figure 2 5 therefore depicts a very unforgiving composition profile Case Study 2 9 Accumulation Causes Corrosion in Chlorinated Hyrocarbon Tower 37 Achieving the design separation depends upon the lower packed bed successfully developing eight theoretical stages Should this number fall a stage or two short the concentration of HK in the vapor side draw would skyrocket with product going severely off specification Sources that can make the number of stages fall short of expectation b
83. uced with permission Copyright 1995 AIChE All rights reserved Case Study 1 16 Do Good Correlations Make the Hydraulic Calculations Reliable 23 What follows is an actual letter circulated by an engineer working for a reputable company The names of the correlations cited as well as a few sentences were changed to protect those involved We have had a problem recently with the prediction of flooding in packed towers using the Smith correlation for packed tower capacity in the Evertrue Simulator We used this for sizing a packed tower at 400 psia The program predicted a percentage flood of 56 percent using the Smith correlation The vendor predicted 106 percent of flood and 123 percent of the packing useful capacity The Evertrue calculation is based on an article by Smith in Quality Chemical Engineering magazine Smith s method in turn depends on an earlier correlation by Jones also published in an article in Quality Chemical Engineering These correlations are neither well developed nor tested Neither of these articles Smith s and Jones have undergone very close scrutiny nor are the correlations from well known textbooks or journals that have a tradition of peer review One of the failings is the use of the correlation at high pressure with hydrocarbon systems Smith s correction factor for high pressures produces numbers that are unreasonably high There is no indication that this factor is supported either by correlatio
84. ude tower bottom composition from assay distillation data for a light crude oil The simulation estimated that all of the vacuum tower feed vaporized in the flash zone This was a preposterous result inconsistent with plant data Investigation The heaviest assay cuts fell progressively lower than those from another assay of the same crude oil The heaviest cut was at 850 F atmospheric cut point compared to the other assay at 1000 F The assay data were extrapolated on a linear scale to 100 at 1150 F atmospheric boiling point The high boiling part of crude assay data must be carefully assessed The last sev eral assay points are often poor particularly when coming from laboratories that cut back on quality control for increased productivity Crude oils have very high boiling point material Even light crude oils have material boiling above 1500 F Extrapola tion should be done with percent distilled on a probability type scale particularly for light crudes where the slope increases very rapidly on a linear scale Solution A new boiling point curve was developed Another assay was used up to 1000 F cut point thus reducing the needed extrapolation range Extrapolation and smoothing of assay data were based upon a probability scale for percent distilled 12 Chapter 1 Troubleshooting Distillation Simulations A 95 point whole crude oil basis of 1400 F was estimated by this extrapolation Simulation based upon the new boiling point curve w
85. ue The simulation showed almost no vapor in the stripping part of the column The heater outlet temperature could not be increased beyond 330 C to generate additional vapor due to vibration of the 75 m long heater outlet line The simulation showed that heater outlet temperatures even as high as 350 360 C would have been insufficient for achieving the diesel flash point speci fication The reason for poor operation was the new feed composition The reason for the heavier feedstock was a revamp of the atmospheric tower of the crude oil distillation unit that took place at the same time as the last stage of the revamp of the hydrotreating unit The crude tower revamp added a diesel draw in order to send light diesel directly to product blending and to dewax the heavy diesel only Case Study 2 4 Heavies Accumulation Interrupts Boil Up 27 Solution During the next turnaround the stripping steam line was reconnected Simultaneous use of stripping steam and reboiling allowed the tower to achieve the product specification CASE STUDY 2 3 POOR H S REMOVAL FROM NAPHTHA HYDROTREATER STRIPPER Contributed by Mark Pilling Sulzer Chemtech Tulsa Oklahoma Installation Naphtha hydrotreater stripper stripping H2S from naphtha Problem Tower had been operating fine for extended period At a later time it could no longer meet H2S specification for bottom product Troubleshooting The tower was operated at the same bottom temperature as it always had be
86. velopment of individual company standards and procedures Copyright 2006 by John Wiley amp Sons Inc All rights reserved Published by John Wiley amp Sons Inc Hoboken New Jersey Published simultaneously in Canada No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording scanning or otherwise except as permitted under Section 107 or 108 of the 1976 United States Copyright Act without either the prior written permission of the Publisher or authorization through payment of the appropriate per copy fee to the Copyright Clearance Center Inc 222 Rosewood Drive Danvers MA 01923 978 750 8400 fax 978 646 8600 or on the web at www copyright com Requests to the Publisher for permission should be addressed to the Permissions Department John Wiley amp Sons Inc 111 River Street Hoboken NJ 07030 201 748 6011 fax 201 748 6008 or online at www wiley com go permission Limit of Liability Disclaimer of Warranty While the publisher and author have used their best efforts in preparing this book they make no representations or warranties with respect to the accuracy or completeness of the contents of this book and specifically disclaim any implied warranties of merchantability or fitness for a particular purpose No warranty may be created or extended by sales representatives or written sales materials The advice and s
87. ween the simulation and plant data and applying graphical techniques to troubleshoot the simulation 255 Case histories involving these issues account for about two thirds of the cases reported in the literature Add to this ensuring correct chemistry and correct tray efficiency these items account for 85 of the cases reported in the literature A review of the VLE case studies 247 revealed major issues with VLE pre dictions for close boiling components either a pair of chemicals e g hydrocarbons HCs of similar vapor pressures or a nonideal pair close to an azeotrope Correctly estimating nonidealities has been another VLE troublespot A third troublespot is characterization of heavy components in crude oil distillation which impacts simu lation of refinery vacuum towers Very few case histories were reported with other systems VLE prediction for reasonably ideal relatively high volatility systems e g ethane propane or methanol ethanol is not frequently troublesome The major problem in simulation validation appears to be obtaining a reliable consistent set of plant data Getting correct numbers out of flowmeters and lab oratory analyses appears to be a major headache requiring extensive checks and rechecks Compiling mass component and energy balances is essential for catching a Distillation Troubleshooting By Henry Z Kister Copyright 2006 John Wiley amp Sons Inc 2 Chapter 1 Troubleshooting Distillation Simulat
88. worked with have used equa tions of state and these were unable to correctly predict the high activity coefficient of the methanol They therefore incorrectly predicted that all the methanol would end up in the bottom and none would reach the tower top product Solution In most cases the methanol was injected upstream for a short period only and the off specification propylene product was tolerated often blended in storage In one case the methanol content of the propylene was lowered by allowing some propylene out of the C3 splitter bottom at the expense of lower recovery Related Experience A very similar experience occurred in a gas plant de propanizer separating propane from butane and heavier HCs Here the methanol ended in the propane product Other Related Experiences Several refinery debutanizers that separated C3 and C4 liquefied petroleum gases LPGs from Cs and heavier HCs naphtha contained small concentrations of high boiling sulfur compounds Despite their high boiling points well within the naphtha range these high boilers ended in the overhead LPG product Sulfur compounds are polar and are therefore repelled by the HC tray liquid The repulsion characterized by their infinite dilution activity coefficient made these compounds volatile enough to go up with the LPG Again tower simulations that were based on equations of state incorrectly predicted that these compounds would end up in the naphtha 4 Chapter 1 Trouble
89. y one or two were and usually are abundant These include a slightly optimistic design HETP inaccuracies in VLE differences between design and ac tual feed compositions relatively small scale fouling or maldistribution and even disturbances to the feed and the heating and cooling media CASE STUDY 2 9 WATER ACCUMULATION CAUSES CORROSION IN CHLORINATED HYROCARBON TOWER Installation A tower separating HCl and HC gases from chlorinated HCs Fig 2 6 There was a very small amount of water 3 ppm in the feed HCI C3 33 C Corrosion HCI here C3 Chlorinated HCs water 3 ppm Chlorinated HCs Figure 2 6 Water accumulation in chlorinated hydrocarbon column 38 Chapter 2 Where Fractionation Goes Wrong Problem There was severe corrosion on trays 15 30 There was no corrosion at the top 5 trays and the bottom 15 trays The column run length was less than a month afterward it needed shutting down to replace the trays Cause Top temperature was too cold and bottom temperature too hot to allow water to escape In the bottom section repulsion of water by the chlorinated HCs increased its volatility As a result the water became trapped in the tower and concen trated near the feed The accumulation could be predicted using a NRTL or UNIQAC model but not using ideal solution or equation of state models Solution The problem was resolved by replacing trays 15 30 by trays fabricated from Hastelloy C Related Experience A d

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger Mode d`emploi - Lyre-jet  Ambient ACL 204 Lock-it Box Manual  Samsung 22" LED Монитор серии M 2233BW Инструкция по использованию  Teledyne API Model 751 Zero Air Generator  gazettes n°63 - Foyers Ruraux du Centre  Registrador de Medidas Landis + Gyr RMC  取扱説明書/837KB  manual tder - ELOS Eletrotécnica Ltda.  Single RF User Manual 2.2.cwk (WP)  SYSTEME DE GESTION MOTEUR  