Central Heating Troubleshooting Advice
Contents
1. HAPPENING THIS MAY PRESENT AN INCREASED SLIPPING HAZARD ON EXTERNAL PATHS WHICH THE CUSTOMER DOES AT THEIR OWN RISK When you think the pipe may be unfrozen try switching on the boiler again You may need to reset the boiler to do this If the boiler fires it up it s fixed If not you could try to unfreeze the pipes again Still got a problem Arrange an appointment for an Aaron engineer to call Our engineer can unfreeze the pipe and advise you on ways to prevent this in the future Version 1 0 Document Ref CHTSA Aaron Services Ltd Standard Form What could be the cause In long periods of cold weather the condensate pipe of your boiler a waste pipe that carries condensation from the boiler to your drain outside can freeze especially if it s exposed or incorrectly installed This can leave you without heat and hot water as the boiler has an in built safety device to prevent any damage to the system Version 1 0 Document Ref CHTSA
2. Aaron Services Ltd Standard Form ON AARON SERVICES LTD S i Central Heating Troubleshooting Advice Troubleshooting checklist There could be a number of reasons why your central heating or hot water system is not working You may be able to fix several problems yourself which in turn avoids an engineer visit from Aaron Services Ltd Please try these tips first e Check that the gas oil electrical and water supplies to the heating appliance are turned on It s surprising how easily they can get accidentally switched off e If relevant check that you have sufficient credit in your gas and electric card meters e Check that the room thermostat is turned up and the clock timer programmer is switched on e Got a system with a permanent pilot light Check that it hasn t gone out this is a very common problem with older gas appliances e Try putting your heating on maximum for a short while to see if you can get it back into action e Have the clocks gone forward or back Your clock programmer might just need adjusting to the correct time Version 1 1 Document Ref CHTAS Aaron Services Ltd Standard Form e Has there been a power cut recently Your heating clock programmer may have returned to its factory settings when the power came back on Test the central heating by setting it to come on in 15 minutes time if that works simply re enter your preferred settings e Do you have a customer operated reset switch not one th
3. at needs you to remove any casing These are usually found on the front of modern boilers Please check your appliance user manual to see if it needs resetting e Try turning the electrical supply to the boiler off and on the switch is usually near the boiler or in the airing cupboard This might reset your boiler and resolve the problem e Could you have frozen pipes In periods of long cold weather the condensate pipe of your boiler can freeze Please see My pipes have frozen below e Are other gas appliances affected If so the problem is bigger you will need to contact your landlord so that we can then make a mutually convenient appointment for an engineer to attend e Some heating systems with a hot water cylinder may also have an immersion heater fitted as a back up to the heating appliance In the event of a boiler failure you can switch on the immersion heater via the spur switch timer that is usually located within the same airing cupboard space Please remember to switch back off once the heating appliance is operational again For open vented system boilers You have this type of boiler if it has a small black tank You ll usually find these in the loft Has the ball valve float in the feed and expansion cistern got stuck this is usually a small plastic cistern situated in the loft If so when your water system falls to a certain point system water can t circulate If you can safely and easily get into and m
4. ove around your loft check to see if the ball valve is Version 1 0 Document Ref CHTSA Aaron Services Ltd Standard Form stuck usually indicated by no or low water in the cistern Gently move the ball float valve arm to free it do not use force This may solve the problem PLEASE BE AWARE OF THE DANGERS OF ENTERING A LOFT SPACE AND THAT DOING SO IS ENTIRELY AT YOUR OWN RISK For sealed system boilers or combination boilers You have this type of boiler if it doesn t have a cistern that looks like a smaller version of your cold water cistern e Has the system pressure dropped This is sometimes caused by water leaks and can stop the boiler from working properly 1 check the pressure gauge this should be set at approx 1 bar A red indicator needle sometimes shows the position set when the boiler was installed 2 look in your appliance user manual to see if you can re pressurise the boiler yourself you can also find instructions on the rear of the control panel If your boiler panel needs tools to remove it do NOT touch it make an appointment for an Aaron engineer to call instead My pipes have frozen To try unfreezing the boiler condensate pipe yourself follow these steps you may need to repeat them several times 1 hold a hot water bottle or heat wrap around the pipe 2 pour hot not boiling water over the frozen end of the pipe with a watering can jug or kettle BE AWARE THAT IF THERE IS A VERY HARD FREEZE STILL
Download Pdf Manuals
Related Search
Related Contents
User Manual - Amazon Web Services MPP Programme Dépliant 2011-2 AX4E-Centos5.4-Dahdi-User Manual-V1.0-EN FM 3-34.331 - GT Emtec microSDHC 16GB 60X Scheda Tecnica - Antifurti Antincendi Automatismi Videocontrolli CAP00139001-03-E-Product Guide Spec Sheets-UHD.indd Terms & Conditions - Wall to Wall Communications Istruzioni per l`uso Caricatore frontale FE EcoLine Copyright © All rights reserved.
Failed to retrieve file